HomeMy WebLinkAboutMFP17004321DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17004321
IVR Number: 17004321
Permit Informa!on
Permit Name:Comcast Cable Franchise Permit
Address/Loca!on:09/08/2017Applica!on Date:2323059044Parcel Number:16023 SE 144TH ST
Permit Type :09/14/2017Issue Date:Franchise
Permit Work Class:09/14/2018Expira!on Date :Minor U#lity
Job Number:JT#244103Franchise Type :Cable
Descrip!on:Due to frontage improvements PSE has placed new poles . Comcast has to relocate facili#es to the new poles . Once
the new service is installed the old poles will be removed. Overhead approved per Ann Fowler Email regarding Alpine
Nursery.
Contacts
Name Address PhoneTypeBilling
Comcast Cable Communica#on Management &
Comcast Cable Holding
B: (215) 665-1700Applicant
Tom Donnelly
Comcast Business Communica#ons LLC
1701 J: Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Sco< Nall
SEFNCO Communica#ons Inc
2904 4th Ave NE
Puyallup, WA 98372
B: (877) 385-2903
C: (253) 444-9057
Contractor
Construc!on Contractor : SEFNCCI850QD
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
Specialized
Billing
X
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP17004321Scott WarlickJustin Johnson9/14/179/14/17
I_______________TRAFFICCONTROLPLANPROJECTNAME:JT#228454PERMIT#______________CONSTRUCTIONCOMPANY:SEENCOCommunicationsPHONE#:2534056263CONTACTNAME:JamesPiercePHONE#:______________ADDRESS:4610TacomaAye,Sumner,WA98390CELL#:2534056263E-MAILADDRESS:jpierce@sefnco.comFAX#:______________PROJECTLOCATION:_16005SF144thST.N/E/5/WOF:___________________WORKTIME:9AM-3PMAPPROVEDBY:___________________WORKDATE:TBD-PENDINGOTHERPERMITSAPPROVALDATE:3—117-PermitHolderagreestoallthefollowing:•ComplywithalltrafficregulationsoftheCityofRentonandtheStateofWashington.•PrepareatrafficcontrolplanandobtainCityapprovalofthatplan.Thatplanshallbeimplementedforallstreetandlaneclosures,andtheplanshallbeperformedincompliancewiththeManualonUniformTrafficControlDevices.•Notifyemergencyservices(253-852-2121)twenty-four(24)hoursbeforeanystreetorlaneclosures.•Anylaneorstreetclosuresnotinconformancewiththeapprovedtrafficcontrolplanand/orwithoutnotificationofemergencyservicesmayresultinreceivingacitationforviolationofR.C.W.47.36.200through47.36.220,9A.36.050RecklessEndangerment,andotherapplicableStateandCitycodes.•IndemnifyandholdharmlesstheCityofRentonfromanyandallclaims,actions,andjudgments,includingallcostsofdefenseandattorney’sfeesincurredindefendingagainstsame,arisingfromandrelatedtoimplementationoftheapprovedtrafficcontrolplansincludingclaimsarisingfromtowingofprivatevehiclesandtheactsofthePermitHolder’sagentsandemployees.•TheCityofRentonshallbeentitled,initsreasonablediscretion,tosettleclaimspriortosuitorjudgment,andinsucheventshallindemnifyandholdharmlesstheCityforanysuchclaimspaid,includingtheCity’sreasonableattorney’sfeesandlitigationcostsincurredresultingfromsuchclaim.•IntheeventanyclaimorsuitisbroughtagainstCitywithinthescopeofthisAgreement,PermitHolderwillpayforlegalcounselchosenbytheCitytodefendagainstsame.•FlaggerandsignplacementaresubjecttorevisionbytheCityInspectoronsite,ifneededtoaddresstrafficorpedestriansafetyortravel.•Bymysignatureherein,Iacknowledgealltheaboverequirements.PRINTNAME:VDATE:(((‘(SIGNATURE:OFFICECOPYTCONTRACTORDEV.SERVICE,INSPECTIONK.KITrRICK/0EV.SERVICE,PLANREVIEWA.HENNINGER/J.ICLIANPOLICECLARKWILCOXFIREDAVIDPARGARS/STA.#13/MFP17004321
NOTES:•WorkZoneTrafficControlshallbeinaccordancewiththeManualonUniformTrafficControlDevices(MUTCD)andshownbysketchorreferencetoWSDOT.•TheplanmustbesubmittedtotheCity’sPW/TransportationDivisionforreviewand/orapprovalatleastthreeworkingdayspriortowork.•ApprovedTemporaryTrafficControlPlanmustbeattheworksiteduringworkhours.•ContractororentitymustcallRentonSchoolDistrict(425-204-4455)oranypublic/privateagencytobeaffectedbyatemporarylaneorroadclosure.•Completeassistanceandaccommodationshallbeprovidedtoallkindsofpedestriantrafficwhensidewalkorwalkwayisimpeded.•Totalroadclosurelastingmotethan24hour5issubjecttotheapprovalbytheCityCouncil.•Anyvehicle,equipment,barricade,orportabletow-awaysignusedwithintheworkareamustdisplayacompanylogooranylegallyacceptablesignshowingthecompanyname,address,andtelephonenumberataconspicuousplaceonthevehicleorequipment.InthecaseofTemporaryNoParkingZones,allthefollowingapplyinadditiontoprevious:•ContractormustcompleteformtoshowlimitsofTemporaryNoParkingZoneidentifyingbarricadelocationsforvacateparkingorcurblaneusage.•ContractormustpostnoticeofdatesandtimeofTemporaryNoParkingZonewithatleasttwosignsperblock72hoursinadvanceofeffectivedateandtime.•ThecoversheetofthisTrafficControlPlanformmustbeattachedtoeachTemporaryNoParkingSignontheprojectsite.•Temporarytrafficcontroldevicesmustberemovedimmediatelywhenworkisdoneornoconstructionactivitiesaregoingon.Ifdeemedabandoned,CitycrewswillremoveandstorethemattheCity’smaintenanceshop(3555NE2’Street).SKETCH--NORTH--c,I-IML3ENStA-LL--‘--wcM
PERMIT:ADDRESS:
WORK HOURS:
REQUESTED DATES:
Summary of Devices
5 - 48" Road Work
Ahead
5 - 48" One Lane Road
Ahead
5 - 48" Flagger Symbol
30 - Cones
5 - Flaggers
REVIEWED:
NOT DRAWN TO SCALE
One Lane - Two Way
NOTES:
70
105
150
205
270
450
500
550
600
650
700
5
6
8
8
10
16
14
15
16
17
19
Merging Devices
35
55
75
105
135
225
250
275
300
325
350
3
4
5
5
6
9
8
8
9
9
10
L
Shifting
1/2 L
Devices
10 feet
75
115
165
225
295
495
550
605
660
715
770
5
7
9
9
11
18
15
16
18
19
20
40
60
85
Merging
115
Devices
150
250
275
305
330
370
385
3
4
5
5
6
9
8
9
9
10
11
L 1/2 L
11 feet
Shifting
80
Devices
125
180
245
320
540
600
660
720
780
840
5
7
10
9
12
19
16
18
19
21
22
45
65
90
125
160
270
300
Merging
330
Devices
360
390
420
3
4
5
5
6
10
9
9
10
11
12
L 1/2 L
12 feet
25
35
50
70
Shifting
90
Devices
150
170
185
200
220
3
3
3
4
4
6
6
6
6
7
7
1/3 L*
Shoulder Taper*
DevicesLength
Offset (W)
Speed (S)
(mph)
20
25
30
35
40
45
50
55
60
65
70
Buffer
Space
115
155
200
250
305
360
425
495
570
645
730
20
20
20
30
30
40
40
40
40
40
40
40
40
60
80
Max. Channelizing
Device Spacing
TangentTaper
235
SIGN SPACING
MPH
100'
(Seattle 150'
SeaTac 200')
X
60
35
30
25
800'
350'
200'
45 500'
30
60
60
80
80
80
80
P
Message
UPO
ROAD
WORK
AHEAD
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
ONE LANE
ROAD
AHEAD
100'
100'
100'
100'
100'
100'
100'100'100'
100'100'100'
100'
100'
100'
duffy@rainierasphalt.com
253-545-13211 6 0 t hA v e S E1 6 0 t hA v e S E1 6 0 t hA v e S E
S E 1 4 4 t h S t
S E 1 4 4 t h S t
Gravel Roads
www.invarion.com
MFP17004321
feet
meters
600
100
MFP17004321
MFP17004321
Approved per e-mail from
ann fowler dated
4/4/2017
From: Ann Fowler
Sent: Tuesday, April 04, 2017 9:16 AM
To: 'Paul Ollestad' <pollestad@tollbrothersinc.com>
Cc: Justin T. Johnson <JTJohnson@Rentonwa.gov>
Subject: Alpine Nursery PSE Undergrounding and 161st Paving
Paul –
The City has reviewed your email regarding the PSE
undergrounding for SE 144th Street. The City concurs that the
project would be exempt from undergrounding the power poles
along SE 144th Street under exception 1.f - Replacement of
overhead facilities for a distance of three (3) or more spans (four
(4) poles). Since there is the potential for future development
along SE 144th Street and 160th Ave SE, the applicant would be
required to install conduit in accordance with exemption 1.g along
the frontages of SE 144th Street and 160th Ave SE.
With regards to the pavement subgrade and base course layer for
the proposed improvements to 161st Ave SE, we concur that the
existing native materials will provide an adequate subgrade for the
portions of SE 161st Street which have been impacted as a result
of the water line relocation. The portions of 161st Ave SE to
receive the full grind and overlay of the existing 2” HMA can be
rehabilitated using a new 4-inch HMA asphalt surface above the
native soil subgrade per the geotechnical recommendations
provided by Tracy from Team Nelson, dated 3/31/2017. The
remaining portions of 161st Ave SE shall be installed per plan.
~Thanks
Ann Fowler
Civil Engineer II
Department of Community and Economic Development
City of Renton | 1055 South Grady Way, 6th Floor | Renton, WA
98057
Phone: 425-430-7382 | Fax: 425-430-7300
E-Mail: afowler@rentonwa.gov
Website: www.rentonwa.gov
P Please consider the environment before printing this email