Loading...
HomeMy WebLinkAboutMFP17004699DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP17004699 IVR Number: 17004699 Permit Informa!on Permit Name:Comcast Cable Franchise Permit Address/Loca!on:09/18/2017Applica!on Date:1823059070Parcel Number:101 S 2ND ST Permit Type :10/13/2017Issue Date:Franchise Permit Work Class:10/13/2018Expira!on Date :Minor U#lity Job Number:256363Franchise Type :Cable Descrip!on:Tie into ROW vault. Bore 1(2") conduit 280' to private property. Crossing 1' of ROW Contacts Name Address PhoneTypeBilling Comcast Cable Communica#on Management & Comcast Cable Holding B: (215) 665-1700Applicant Tom Donnelly Comcast Business Communica#ons LLC 1701 J; Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Sco= Nall SEFNCO Communica#ons Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: BL.041108Construc!on Contractor : SEFNCCI850QD CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 Specialized Billing X General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date PLEASE RETURN APPROVED ROW AND TCP TO ASHLEY KIEHN. 4610 TACOMA AVE SUMNER, WA 98390 EMAIL: AKIEHN@SEFNCO.COM / PHONE: 253.299.8588 MFP17004699 Scott Warlick 10/6/2017 Justin Johnson 10-12-2017 REVISION DESCRIPTIONS 9 PLAN SET COVER SHEET ENGINEERED FOR: NEW UG FOOTAGE = OVERLASH FOOTAGE = EXISTING UG FOOTAGE = DATE:BY:REASON: Robbie Hines (253)370-8257 SCREEN PRINT PASTE CROP GOOGLE STREET MAP HERE 6 7 8 Engineering / Design SOW OVERVIEW DETAIL 2 RENTON SOW DETAIL VIEW NICK ARMENDARIZ PLAN SET COVER PAGE 1 425-988-2414 3 4 Thomas Guide Page 256363 CONTACTS: SCREEN PRINT PASTE CROP GOOGLE MAP Area Manager TACTON INC TACO TIME NW RENTON Kevin Kindle 101 2ND ST OPE SEFNCO Robbie Hines (253)370-8257 OPE COMCAST Kyle Kinney SECTIONS: ROW FOOTAGE = 354' SITE CONTACT 5 RENTON PERMIT RISER FOOTAGE = TOTAL FOOTAGE = 355' 1' SOW DETAIL VIEW 2 N E S W NESESENWSEFNCOCOMMUNICATIONS MFP17004699 Place Large Photo Detail Here 256363 TACTON INC TACO TIME NW RENTON 101 2ND ST RENTON SOW Detail Overview Prepared By:Robbie Hines (253)370-8257 Rev Tie into existing Comcast vault in ROW. Bore 1(2") conduit with cable 285' to new vault loction. Onto private property. Date: ENGINEERED FOR:SMB Kyle Kinney Comcast ope Date N E S W NESESENWSEFNCO COMMUNICATIONS 285' 70' 101 Tie in Place 2 port tap Tie into existing vault Bore 1(2") conduit with cable Place 17"x30" vault 1 Core drill 1(2") hole MFP17004699 route appears to go through stormwater vault may need to relocate route on private property. Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Prepared By:Robbie Hines (253)370-8257 Rev 256363 TACTON INC TACO TIME NW RENTON 101 2ND ST RENTON SOW Detail View Date Tie into existing Comcast vault in ROW. Bore 1(2") conduit with cable 285' to new vault loction. Onto private property. Date: ENGINEERED FOR:SMB Kyle Kinney Comcast ope N E S W NESESENWSEFNCOCOMMUNICATIONS Tie into existing vault Bore 1(2") conduit with cable Continue bore 1(2") conduit with cable to new vault location Continue bore 1(2") conduit with cable to new vault location Continue bore 1(2") conduit with cable to new vault location Place 17"x30" vault with 2 port tap Bore 1(2") conduit with rg6 drop to side of building Continue bore 1(2") conduit with rg6 drop MFP17004699 Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Place Photo Detail Here Prepared By:Robbie Hines (253)370-8257 Rev 256363 TACTON INC TACO TIME NW RENTON 101 2ND ST RENTON SOW Detail View Date Tie into existing Comcast vault in ROW. Bore 1(2") conduit with cable 285' to new vault loction. Onto private property. Date: ENGINEERED FOR:SMB Kyle Kinney Comcast ope N E S W NESESENWSEFNCOCOMMUNICATIONS Continue bore 1(2") conduit with rg6 drop Place 10' of 2" conduit on side of building Core drill 1(2") hole and place junction box/coil remaining rg6 drop in false ceiling MFP17004699