Loading...
HomeMy WebLinkAbout256918_DETAILED SOW R1NESWSEFNCOCOMMUNICATIONSSOWSOWJT#256918FILE NAME:256918_DETAILED SOWDATE:CREATED 9/25/17PAGE:1 of 5ENGINEERED FOR:Not to scale. Do not use for locating.Verification of all utilities is the contractors responsibility. WA Dig line can be reached by dialing 811, WA law requires a 48 hour notice prior to digging.SERVICE KING JOB#:4000 E VALLEY RDRENTON, WA 98057CONTACT PERSON:SEFNCO COMMUNICATIONSKYARA SCHROEDER4610 TACOMA AVE.SUMNER, WA 98390Office (253) 299-8565Mobile (253) 405-5304KSCHROEDER@SEFNCO.COMSECTION INDEX:1 – COVER SHEET/ PROJECT LOCATION2 – OVERVIEW RENTON3 – DETAILED VIEW (ROW)4 – DETAILED VIEW (PRIVATE)COMCAST COMMUNICATIONS LLCKYLE KINNEY410 VALLEY AVE BLDG C ST 12PUYALLUP, WA 98371OFFICE(253) 864-4281MOBILE(206) 510-4222KYLE_KINNEY@comcast.comPROJECT TOTALSINTERIOR CONDUIT/COAXNEW PRIVATE UNDERGROUNDNEW ROW UNDERGROUNDNEW OVERLASH25'30'500'0TOTAL FOOTAGE555'RISER0PROJECT SCOPE:COMCAST PURPOSES TO TIE INTO EXISTING SYSTEM AND BORE ~500' AND PLACE 2 (2") SCH 40 CONDUITS IN ROW; PLACE 2 NEW VAULTS; BORE ~30' AND PLACE 1 (2") SCH 40 CONDUIT TO BUILDING; CORE DRILL AND OVERSET WITH LB; RUN ~25' OF COAX TO UTILITY CLOSET. 256918253‐293‐3838 Kyara SchroederPrepared By:REV 1Date:2 OF 5PROJECT SCOPE:COMCAST PURPOSES TO TIE INTO EXISTING SYSTEM AND BORE ~500' AND PLACE 2 (2") SCH 40 CONDUITS IN ROW; PLACE 2 NEW VAULTS; BORE ~30' AND PLACE 1 (2") SCH 40 CONDUIT TO BUILDING; CORE DRILL AND OVERSET WITH LB; RUN ~25' OF COAX TO UTILITY CLOSET. SMBKYLE KINNEY9/25/17OVERVIEW256918SERVICE KING4000 E VALLEY RDRENTON, WA 98057NESWSEFNCOCOMMUNICATIONSSYMBOL KEYNEW COMCAST VAULT/PEDNEW UNDERGROUND (BORE/TRENCH) UTILITY/DATA AREAEXISTING COMCAST VAULT/PEDLOT LINES/EDGE OF ROWNEW INTERIOR/EXTERIOR COAX2" CORE DRILL W/ LB & SEALANTUC0160'340'UC1SERVICED UNITS30'8'125'DRILL CREW SET UP LOCATIONDRILL CREW SET UP LOCATIONDIRECTIONAL DRILL @ 36" MIN;PLACE 2 - 2" PIPE;PLACE COAX CABLEDIRECTIONAL DRILL @ 36" MIN;PLACE 2 - 2" PIPE;PLACE COAX CABLEDIRECTIONAL DRILL @ 36" MIN;PLACE 1 - 2" PIPE;PLACE COAX CABLEPLACE EXTERIOR CONDUIT ON SIDE OF BUILDING; CORE DRILL 2" AND SEAL WITH LBBRING COAX DROP THROUGH DROP CEILING AND INTO UTILITY CLOSET Kyara SchroederPrepared By:REV 1Date:3 OF 5SMBDETAILED VIEWNESWSEFNCOCOMMUNICATIONSKYLE KINNEY9/25/17256918SERVICE KING4000 E VALLEY RDRENTON, WA 98057SYMBOL KEYNEW COMCAST VAULT/PEDNEW UNDERGROUND (BORE/TRENCH) UTILITY/DATA AREAR 25POLE RISEREXISTING COMCAST VAULT/PEDNEW OVERLASHEXISTING UNDERGROUNDNEW INTERIOR/EXTERIOR COAX12"X18" LOCK BOX 2" CORE DRILL W/ LB & SEALANTUTILITY POLEUC1SERVICED UNITSTIE IN POINTBORE 2 (2") SCH 40 CONDUITSW 41ST STSW 41ST ST AND E VALLEYBORE 2 (2") SCH 40 CONDUITE VALLEY RDBORE 1 (2") SCH 40 CONDUITCORE DRILL 1(2") AND OVERSET WITH LBBORE 2 (2") SCH 40 CONDUITPLACE NEW VAULTPLACE NEW VAULT KyaraSchroederPrepared By:REV 1Date:4 OF 5SMBDETAILED VIEWNESWSEFNCOCOMMUNICATIONSKYLE KINNEY9/25/17256918SERVICE KING4000 E VALLEY RDRENTON, WA 98057SYMBOL KEYNEW COMCAST VAULT/PEDNEW UNDERGROUND (BORE/TRENCH) UTILITY/DATA AREAR 25POLE RISEREXISTING COMCAST VAULT/PEDNEW OVERLASHEXISTING UNDERGROUNDNEW INTERIOR/EXTERIOR COAX12"X18" LOCK BOX 2" CORE DRILL W/ LB & SEALANTUTILITY POLEUC1SERVICED UNITSFIRE PENETRATE AND CON’T DROP ALONG CEILINGNORTH END OF SERVICE REPAIR SHOPFROM CEILING DROP INTO UC AND LEAVE 5' COILEDUC OF SERVICE KINGFACING WEST INSIDE UCRUN COAX INTO HALLWAY