Loading...
HomeMy WebLinkAboutMFP17005410DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP17005410 IVR Number: 17005410 Permit Informa!on Permit Name:Comcast Cable Franchise Permit Address/Loca!on:11/14/2017Applica!on Date:3702950010Parcel Number:5255 NE 3RD PL Permit Type :02/21/2018Issue Date:Franchise Permit Work Class:02/21/2019Expira!on Date :Major U$lity Job Number:JT#184666Franchise Type :Cable Descrip!on:PRE CONSTRUCTION MEETING REQUIRED APPROVED WITH COMMENTS OR REDLINES Overlash 1300' of new fiber to exis$ng poles. Proof and pull 520' of fiber through exis$ng conduit underground. Restora$on per City of Renton Standards . Contacts Name Address PhoneTypeBilling Comcast Cable Communica$on Management & Comcast Cable Holding B: (215) 665-1700Applicant Tom Donnelly Comcast Business Communica$ons LLC 1701 JD Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact ScoF Nall SEFNCO Communica$ons Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Construc!on Contractor : SEFNCCI850QD CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 Specialized Billing X General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Restoration per City of Renton Standards.MFP17005410Scott Warlick2/12/2018Justin Johnson2-19-2018 MFP17005410Justin Johnson2-19-20189:00 am to 3:00 pmMonday through Friday EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOPEOPEOPEOPEOPPOLE-6 WORKVEHICLE144TH AVE SEROAD WORK AHEAD SHOULDER CLOSED NO PARKING FROM TO TOW-AWAY AREA PHONE (CONTACT #) NAME OF FIRM 000-0000PATH OF AERIAL OVERLASHSPOTTER "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEISSUE FOR:BYQCDATEREVISIONBYQC12858 144TH AVE SERENTON, WA184666SITE SPECIFIC-TCP-11 510/11/17PERMITMNJB02/01/18TCP REV 1MDBCOMCAST SCALE: N.T.S. ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D) CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST 52''&25 30 35 45 50 55 155 200 250 360 425 495 570 .10)+67&+0#.$7(('452#%'$ .'0)6* 40 305 60 65 70 780 840 10 105 150 205 270 450 500 550 --- 11 115 160 225 295 495 550 605 660 -- 12 125 180 245 320 540 600 660 720 780 840 .#0' 9+&6*25 30 35 40 45 50 55 60 65 70 /+0+/7/6#2'4.'0)6*+0(''6. 2156'&52''&.+/+6 /2* 5+6'016'5 MAINTAIN DRIVEWAY ACCESS AT ALL TIMES SIDE WALK TO REMAIN OPEN AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. 5+6'52'%+(+%64#((+%%10641.2.#0 5*17.&'4%.1574'Ä.1952''&41#&9#; ORJ14.19'4 SCHOOL LIMIT SPEED WHEN CHILDREN ARE PRESENT 20 MFP17005410 EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLE-4 POLE-5FLFLFLFLFLFL144TH AVE SENE 2ND ST NE 2ND ST ROAD WORK AHEAD ROAD WORK AHEAD WORKVEHICLEROAD WORK AHEAD SHOULDER CLOSED NO PARKING FROM TO TOW-AWAY AREA PHONE (CONTACT #) NAME OF FIRM 000-0000PATH OF AERIAL OVERLASHSPOTTER "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEISSUE FOR:BYQCDATEREVISIONBYQC12858 144TH AVE SERENTON, WA184666SITE SPECIFIC-TCP-22 510/11/17PERMITMNJB02/01/18TCP REV 1MDBCOMCAST SCALE: N.T.S. ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D) CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST 52''&25 30 35 45 50 55 155 200 250 360 425 495 570 .10)+67&+0#.$7(('452#%'$ .'0)6* 40 305 60 65 70 780 840 10 105 150 205 270 450 500 550 --- 11 115 160 225 295 495 550 605 660 -- 12 125 180 245 320 540 600 660 720 780 840 .#0' 9+&6*25 30 35 40 45 50 55 60 65 70 /+0+/7/6#2'4.'0)6*+0(''6. 2156'&52''&.+/+6 /2* 5+6'016'5 MAINTAIN DRIVEWAY ACCESS AT ALL TIMES SIDE WALK TO REMAIN OPEN AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. 5+6'52'%+(+%64#((+%%10641.2.#0 5*17.&'4%.1574'Ä.1952''&41#&9#; ORJ14.19'4 SCHOOL LIMIT SPEED WHEN CHILDREN ARE PRESENT 20 MFP17005410 V EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPPOLE-3 POLE-2FLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL144TH AVE SENE 2ND PL ROAD WORK AHEAD POLE-5WORKVEHICLE ROAD WORK AHEAD SHOULDER CLOSED NO PARKING FROM TO TOW-AWAY AREA PHONE (CONTACT #) NAME OF FIRM 000-0000PATH OF AERIAL OVERLASHWORK AREA "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEISSUE FOR:BYQCDATEREVISIONBYQC12858 144TH AVE SERENTON, WA184666SITE SPECIFIC-TCP-33 510/11/17PERMITMNJB02/01/18TCP REV 1MDBCOMCAST SCALE: N.T.S. ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D) CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST 52''&25 30 35 45 50 55 155 200 250 360 425 495 570 .10)+67&+0#.$7(('452#%'$ .'0)6* 40 305 60 65 70 780 840 10 105 150 205 270 450 500 550 --- 11 115 160 225 295 495 550 605 660 -- 12 125 180 245 320 540 600 660 720 780 840 .#0' 9+&6*25 30 35 40 45 50 55 60 65 70 /+0+/7/6#2'4.'0)6*+0(''6. 2156'&52''&.+/+6 /2* 5+6'016'5 MAINTAIN DRIVEWAY ACCESS AT ALL TIMES SIDE WALK TO REMAIN OPEN AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. 5+6'52'%+(+%64#((+%%10641.2.#0 5*17.&'4%.1574'Ä.1952''&41#&9#; ORJ14.19'4 LIMIT SPEED 30 MFP17005410 VEOPEOP EOPEOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL144TH AVE SENE 2ND CT ROAD WORK AHEADWORKVEHICLE ROAD WORK AHEAD SHOULDER CLOSED NO PARKING FROM TO TOW-AWAY AREA PHONE (CONTACT #) NAME OF FIRM 000-0000 WORK AREA SPOTTER "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEISSUE FOR:BYQCDATEREVISIONBYQC12858 144TH AVE SERENTON, WA184666SITE SPECIFIC-TCP-44 510/11/17PERMITMNJB02/01/18TCP REV 1MDBCOMCAST SCALE: N.T.S. ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D) CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST 52''&25 30 35 45 50 55 155 200 250 360 425 495 570 .10)+67&+0#.$7(('452#%'$ .'0)6* 40 305 60 65 70 780 840 10 105 150 205 270 450 500 550 --- 11 115 160 225 295 495 550 605 660 -- 12 125 180 245 320 540 600 660 720 780 840 .#0' 9+&6*25 30 35 40 45 50 55 60 65 70 /+0+/7/6#2'4.'0)6*+0(''6. 2156'&52''&.+/+6 /2* 5+6'016'5 MAINTAIN DRIVEWAY ACCESS AT ALL TIMES SIDE WALK TO REMAIN OPEN AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. 5+6'52'%+(+%64#((+%%10641.2.#0 5*17.&'4%.1574'Ä.1952''&41#&9#; ORJ14.19'4 LIMIT SPEED 30 MFP17005410 V V EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPPOLE-1FLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFL12858 144TH AVE SE144TH AVE SENE 3RD ST NE 3RD ST ROAD WORK AHEAD ROAD WORK AHEAD WORK AREA WORK AREA WORKVEHICLEROAD WORK AHEAD SHOULDER CLOSED NO PARKING FROM TO TOW-AWAY AREA PHONE (CONTACT #) NAME OF FIRM 000-0000 SPOTTER "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEISSUE FOR:BYQCDATEREVISIONBYQC12858 144TH AVE SERENTON, WA184666SITE SPECIFIC-TCP-45 510/11/17PERMITMNJB02/01/18TCP REV 1MDBCOMCAST SCALE: N.T.S. ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D) CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST 52''&25 30 35 45 50 55 155 200 250 360 425 495 570 .10)+67&+0#.$7(('452#%'$ .'0)6* 40 305 60 65 70 780 840 10 105 150 205 270 450 500 550 --- 11 115 160 225 295 495 550 605 660 -- 12 125 180 245 320 540 600 660 720 780 840 .#0' 9+&6*25 30 35 40 45 50 55 60 65 70 /+0+/7/6#2'4.'0)6*+0(''6. 2156'&52''&.+/+6 /2* 5+6'016'5 MAINTAIN DRIVEWAY ACCESS AT ALL TIMES SIDE WALK TO REMAIN OPEN AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. 5+6'52'%+(+%64#((+%%10641.2.#0 5*17.&'4%.1574'Ä.1952''&41#&9#; ORJ14.19'4 LIMIT SPEED 30 MFP17005410 Vault should be located within the landscaping strip. 670' 140' 215' 150' 151' SCOPE OF WORK: SHEET INDEX: 1 - COVER SHEET 2 - NOTES & LEGEND SHEET 3 - DETAILS SHEET 4 TO 6 - DESIGN. BILL OF MATERIALS*: CONTACTS: KE16AB 3X3-(HE UA) N RENTON THIS IS PROPRITORY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED SEFNCO COMMUNICATIONS PROJECT MAP: COVER NEW AREAL =1300' EXISTING U/G =520' TOTAL FOOTAGE =1820' PROJECT DESCRIPTION* 12858 144TH AVE SE, RENTON, WA SEFNCO JOSH BLAKESLEE (253)455-1066 *ALL FOOTAGES AND MATERIALS ARE ESTIMATED "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEREVISIONBYQC12858 144TH AVE SE,RENTON, WA184666PERMIT1 610/11/2017PERMITMNJBCOMCAST COMCAST JT#184666 OVERLASH 1300' OF 36CT FIBER TO EXISTING POLES, AND PROOF AND PULL 520' UNDERGROUND THROUGH EXISTING CONDUIT MFP17005410 NOTES & LEGEND 6 ROW R PROPOSED VAULT PROPOSED BORE PIT STREET/SIGNAL/TRAFFIC LIGHT CONSTRUCTION NOTE CATCH BASIN FIRE HYDRANT EXISTING POLE W/ NEW RISER BUILDING OUTLINE TRAFFIC FLOW LANDSCAPING/TREE POTHOLE LOCATION CHANNELIZATION 5+39 STATIONING (xxx') OPEN TRENCH PROPOSED DIRECTIONAL DRILL EXISTING PULL THRU PROPOSED BORE PROPOSED OPEN TRENCH (xxx') EXISTING PULL THRU (xxx') BORE (xxx') DIRECTIONAL DRILLRIGHT-OF-WAY CENTERLINE TRAFFIC LANE FENCE STORM DRAIN MANHOLE COMMUNICATIONS WATER SEWER POWER GAS D CB S C GAURD RAIL AERIAL STRAND FIBER PLACEMENT NOTES: GENERAL NOTES: DISCLAIMER: 1.IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONTRACTOR TO VERIFY ALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO BEGIN. NO UNDERGROUND INSTALLATION REPRESENTED WITHIN THESE PLAN SHEETS IS PROPOSED OUTSIDE OF THE RIGHT OF WAY. 2.THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND WILL/MAY VARY ONCE UTILITIES HAVE BEEN FIELD LOCATED. 3.ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY DETERMINED DURING CONSTRUCTION AND IS COLLECTED IN THE AS-BUILT PHASE. 1.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 HOURS PRIOR TO CONSTRUCTION ACTIVITY SEE LOCAL DIRECTORY FOR CONTACT TELEPHONE NUMBER OF LOCAL CALL BEFORE YOU DIG AGENCY. 2.CONTRACTOR SHALL RECORD SEQUENCE # OF FIBER CABLE AT EVERY WORK POLE, MANHOLE, FIBER STORAGE LOOP AND TAIL LOCATION. CONTRACTOR TO PROVIDE PROJECT MANAGER WITH SEQUENCE NUMBERS AT PROJECT COMPLETION. 3.SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE DETERMINED ON CONSTRUCTION DRAWINGS, HOWEVER, REEL LENGTHS OF FIVE HUNDRED FEET (500') OR LESS ON LARGE COUNT FIBER OR THREE HUNDRED FEET (300') OR LESS ON SMALL COUNT FIBER ARE DIFFICULT TO USE AND SHOULD BE PLACED AS FSL'S, NOT CUT AND RETURNED. 4.FIBER OPTIC IDENTIFICATION TAGS SHALL BE PLACED AT EVERY WORK POLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE CASES AND WHERE INDICATED BY PROJECT MANAGER. TAGS NEED TO BE PLACED SO AS TO BE READ FROM THE GROUND. 5.CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING TENSION. LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM PRODUCTS. 6.A 100 FOOT FIBER COIL MUST REMAIN IN ALL VAULTS UNLESS OTHERWISE NOTED. 7.ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH WARNING TAPE AND A TRACER WIRE, AT RISER POLES THE LOCATE WIRE SHALL BE ACCESSIBLE AT THE BASE OF THE RISER. 8.ALL RISERS WILL BE CAPPED AT ALL TIMES. 9.ALL FIBER SHALL BE MARKED AS TO DIRECTION IN EACH VAULT. RED-NORTH, GREEN-SOUTH,YELLOW-EAST, AND BLUE-WEST. DO NOT TAPE FIBER CABLES TOGETHER IN RISER. 1. ALL VAULTS / HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITH LOCKING BOLTS. 2. GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. 3. ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF 36" RADIUS UNLESS SPECIFIED OTHERWISE. 4. BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OF ALL ROAD CROSSINGS, AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OF SIGHT SPACING OF APPROXIMATELY 500 FEET. 5. DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRES A PROJECT MANAGER AND RIGHT-OF-WAY OWNER OR CARETAKER APPROVAL PRIOR TO CONSTRUCTION. 6. WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENT AGENCIES ARE REQUIRED, ALL WORK PERFORMED WILL COMPLY WITH THESE AGENCIES STANDARD SPECIFICATIONS. 7. THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORK WILL BEGIN ON BUILDING. CONTRACTOR TO COORDINATE ROOM ACCESS AND WORK START AND STOP TIMES WITH BUILDING MANAGEMENT. 8. THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURS PRIOR TO CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACT NAME(s) AND TELEPHONE NUMBER(s). 9. THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECT AT ANY TIME THE WORK BEING PERFORMED BY THE CONTRACTOR. IF PROJECT MANAGER DETERMINES THAT THE WORK IS NOT BEING PERFORMED TO MINIMUM QUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE REWORK AT HIS OWN COST. 10. ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUIT LENGTH, CONDUIT PATH, AERIAL PATH ETC., MUST BE APPROVED BY THE PROJECT MANAGER. 11. ALL CORING/CONSTRUCTION THAT WILL CAUSE NOISE AND/OR VIBRATION SHALL BE DONE WITHIN ALLOWED (9AM-3PM) BUSINESS HOURS. 12. ANY AND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT, AND REPAIR, IF DAMAGED. 13. ALL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCH SOME VARIANCE SHOULD BE ANTICIPATED. ADJUST AS NEEDED. 14. ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITE HAS POTENTIAL FOR ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THE MINIMUM COVER. IN CASES WHERE THE MINIMUM COVER CAN NOT BE ACHIEVED, THE CONDUIT SHALL BE PLACED IN A SCH 40 EMT SLEEVE OR APPROVED EQUIVALENT. 15. WATER, SEWER, STORM SEWER AND EASEMENT LOCATIONS ARE BASED OFF OF CITY MAPS, NOT FIELD VERIFIED. 16. BORING OF AC PAVING IS REQUIRED AT ALL LOCATIONS AS INDICATED ON PLANS. 17. AT NO TIME SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED. 18.DOOR HANGERS ARE TO BE PLACED A MINIMUM OF 72 HOURS PRIOR TO START OF CONSTRUCTION. 19. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING LANE CLOSURES, AND DELAYS A WEEK IN ADVANCE. LOCATION OF THE MASSAGE BOARD SHALL BE COORDINATED WITH THE CITY INSPECTOR AT THE PRE-CONSTRUCTION MEETING. 20. LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. AT A TIME. FOR SAFETY PURPOSES THERE SHALL BE ONLY ONE CLOSURE AT A TIME ALONG INTERNATIONAL BLVD. MORE FLAGGERS WILL BE NECESSARY TO HELP VEHICLES AND PEDESTRIANS IN THE WORK ZONES DURING THE LANE CLOSURES. LEGEND: V U U U U U U U U U U S W P C G D COMCAST "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEREVISIONBYQC12858 144TH AVE SE,RENTON, WA184666PERMIT2 610/11/2017PERMITMNJBMFP17005410 NO SCALETRENCHMANHOLEUTILITYCROSSING TYPICAL POT HOLE REPAIR DETAILPOT HOLE REPAIRTYPICAL VAULT DETAIL 13" 17" 14" 12" 3" 19"22" 18" PROPOSED FIBER EXISTING GROUND EXISTING UTILITY POLE TYPE C STEEL-TO-STEEL ADAPTER TYPICAL POLE RISERS (2) 4"Ø 3'R, 90° STEEL (1) 10' NOTCHED & (1) 10' STEEL CONDUIT SECTIONS 15" HDG POLE BRACKET W/ PIPE CLAMP (B2017 BY POWER-STRUT OR EQUAL) 4" MIN. OFFSET FROM POLE TYPE C STEEL-TO-STEEL ADAPTER. CAP (1) 4"Ø AT 10'.22' (TYP.)24' (TYP.)HEIGHT VARIES(1) 10' NOTCHED STEEL CONDUIT SECTION POLE RISERVAULTTYPICAL DETAILS 4 5/8" DIA. LIFTING INSERTS ROUND ACCESS COVER 4 3/4" KNOCKOUTS 4 EACH SIDE 2 1/2"Ø GROUND ROD KNOCKOUTS VAULT NO. 444-LA 2,280 LBS. OPTIONAL PULLING IRON1 EACH SIDE TYPICAL MANHOLE DETAIL NO. 3806 6" RISER 280 LBS. 6" 4 - "C" CHANNELS 24" LG. LIFT HOLE 1 1/2" DIA. EACH SIDE LADDER RUNG GROOVES PLACE 8' GROUND ROD W/CLAMP AND ATTACH 10' OF #6 COPPER WIRE. LEAVE 4" OUT OF BOTTOM OF VAULT. 4'-0"38" DIA.LIFT INSERTS 3-5/8" DIA.46" DIA.4'-0" 42" 42" 42" 4'-0" 30"x10" FLANGE DOWN 30"Ø CLEAR OPENING 800 LBS. 6" MAGNETIC LOCATOR TAPE (ENTIRE TRENCH LENGTH) TYPICAL TRENCH DETAIL EXISTING SURFACE CONTRACTOR TO VERIFY SPECIFICATION WITH LOCAL JURISDICTION. PROPOSED CONDUIT BACKFILL COMPACTED TO 90% OF MAXIMUM RELATIVE DENSITY OR STONEWAY MIX 1004. COMPACT TO 95% UNDER ROADWAYS OR STONEWAY MIX 351 OR 1121. SURFACE RESTORATION TYPICAL UTILITY CROSSING DETAIL COMCAST "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEREVISIONBYQC12858 144TH AVE SE,RENTON, WA184666PERMIT3 610/11/2017PERMITMNJBMFP17005410 © 2017 DigitalGlobe ©CNES (2017) Distribution Airbus DS © 2017 Microsoft Corporation © 2017 HERE 670' V V V R OWNER: POLE#: CLASS/HT: POLE TYPE: - ATTACHMENTS - - MAKE READY - HEIGHT 1PSE 318070-167524 COMCAST 19 10 N/A CATV 22 0 N/A POWER 26 0 N/A D COMCAST 1 TIE IN SPLICE CONSTRUCTION NOTES 2 NEW OVERLASH 36CT 3 PROOF AND PULL 36CT THROUGH EXCITING CONDUIT END OF DESIGN. 2 1 4 "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEREVISIONBYQC12858 144TH AVE SE,RENTON, WA184666PERMIT4 610/11/2017PERMITMNJBMFP17005410 © 2017 DigitalGlobe ©CNES (2017) Distribution Airbus DS © 2017 Microsoft Corporation © 2017 HERE © 2017 DigitalGlobe ©CNES (2017) Distribution Airbus DS © 2017 Microsoft Corporation © 2017 HERE 140' V R OWNER: POLE#: CLASS/HT: POLE TYPE: - ATTACHMENTS - - MAKE READY - HEIGHT 2PSE 318006-167523 PHONE 18 5 N/A COMCAST 19 2 N/A CATV 20 0 N/A POWER 27 0 N/A D OWNER: POLE#: CLASS/HT: POLE TYPE: - ATTACHMENTS - - MAKE READY - HEIGHT 3PSE 319770-167522 PHONE 18 2 N/A COMCAST 19 4 N/A CATV 20 5 N/A POWER 24 9 N/A D OWNER:CLASS/HT:4PSE COMCAST CONSTRUCTION NOTES MATCHLINE - SEE SHEET 1 1 TIE IN SPLICE 2 NEW OVERLASH 36CT 3 PROOF AND PULL 36CT THROUGH EXCITING CONDUIT END OF DESIGN.4 MATCHLINE - SEE SHEET 3 "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEREVISIONBYQC12858 144TH AVE SE,RENTON, WA184666PERMIT5 610/11/2017PERMITMNJBMFP17005410 © 2017 DigitalGlobe ©CNES (2017) Distribution Airbus DS © 2017 Microsoft Corporation © 2017 HERE © 2017 DigitalGlobe ©CNES (2017) Distribution Airbus DS © 2017 Microsoft Corporation © 2017 HERE 215' 150' 151' OWNER: POLE#: CLASS/HT: POLE TYPE: - ATTACHMENTS - - MAKE READY - HEIGHT 4PSE 317970-167522 PHONE 18 3 N/A COMCAST 21 11 N/A CATV 23 0 N/A POWER 25 2 N/A STREET LIGHT 24 0 N/A D OWNER: POLE#: CLASS/HT: POLE TYPE: - ATTACHMENTS - - MAKE READY - HEIGHT 5PSE 317953-167521 PHONE 18 6 N/A COMCAST 19 9 N/A CATV 21 5 N/A POWER 25 0 N/A D OWNER: POLE#: CLASS/HT: POLE TYPE: - ATTACHMENTS - - MAKE READY - HEIGHT 6PSE 317937-167521 PHONE 19 2 N/A COMCAST 20 10 N/A CATV 22 1 N/A POWER 27 0 N/A D COMCAST CONSTRUCTION NOTES 5 2 MATCHLINE - SEE SHEET 2 1 TIE IN SPLICE 2 NEW OVERLASH 36CT 3 PROOF AND PULL 36CT THROUGH EXCITING CONDUIT END OF DESIGN.4 "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OFDATEREVISIONBYQC12858 144TH AVE SE,RENTON, WA184666PERMIT6 610/11/2017PERMITMNJBMFP17005410 SEFNCO COMMUNICATIONS 4610 TACOMA AVE SUMNER WA, 98390 5/3/17 To whom it may concern: City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JT#184666 To whom it may concern, SEFNCO Communications has been contracted to design and engineer this project on behalf of Comcast Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to over-lash approximately 1300’ of aerial cable along the right of way of 144th Ave SE, Jericho Ave NE and NE 1st St in order to meet on going service capacity issues. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1. Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2. Potential damage to underground facilities will be increased. 3. Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4. The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5. The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and maintenance of the proposed facilities. MFP17005410 If you have any further questions regarding this project please contact me at 253 299-8587. Thank you for your consideration in this matter. Stefania Spencer Permit Coordinator SEFNCO Communications Attachments: 1. Application for ROW permit 2. 11” x 17” Site plan 3. 11” x 17” Design plan 4. Traffic Control Plan DenisLawMayorI®!Community&EconomicDevelopmentC.E.“Chip”Vincent,AdministratorJanuary5,2018RhondaResnikComcast410ValleyAveNWPuyallup,WA98371ViaEmail:rhondaresnikcomcast.comSUBJECT:RequestforUndergroundingExemption(JT#184666,MFP1700541O)DearMs.Resnik:TheCityofRentonhasreviewedyourrequesttograntComcastanexemptionfromRentonMunicipalCode(RMC)4-6-090(C)whichstatesthatallnewelectricalorcommunicationfacilitiesshallberequiredtobeinstalledunderground,pursuanttothestandardsofthesectionofRMC.ComcastproposestohaveSEFNCOoverlashapproximately1,300linealfeetof36-countCOAXaerialfibertoexistingPugetSoundEnergy(PSE)polesbeginningatthesoutheastcornerofNE3tdPlaceandJerichoAveSE,thengoingsouthalongJerichoAveSEwithapproximately520linealfeetinconduit,andtheremainingfiberinstalledoverheadonexistingPSEpoles.ANALYSIS:TheCityhasconsideredtherequestforanexemptionfromRMC4-6-090(D)(1)(g)iandii.Ordinance5720grantsComcast,therighttoinstallfiberopticcableandrelatedappurtenancesunder,along,over,below,throughandacrossthestreets,avenuesandalleysofCityofRentonwithintheright-of-wayofRenton.Section3.4ofthefranchiseordinancestatesthatifallofthedistributionlinesallthewirelineserviceproviders,suchastelecommunicationsserviceproviders,asdefinedinRCW35.99.010,autilityserviceprovideroraCableOperator(collectively“ServiceProviders”)inanyportionoftheFranchiseAreaareunderground,GranteeshallplaceitsCableSystem’sdistributioncablesundergroundwithinthatarea;providedthatsuchundergroundlocationsareactuallycapableofaccommodatingGrantee’scableandotherequipmentwithouttechnicaldegradationoftheCableSystems’signalquality.TheproposalwouldutilizeexistingpolesandattachtotheexistingComcastaerialpath.Asminimumverticalheightclearanceof15’-6”wouldneedtobeprovidedfor,andexistingobsoletecablewouldneedtoberemoved;staffrecommendstheseasconditionsofapproval.Therefore,theCityisgrantinganexemptionwithconditions,perRMC4-6-090(D)(lflg)iandiiwhichallowsforextensionsofexistingoverheadcommunicationfacilitieswhentherearecontinuingrequirementsforpolesanditisnot1055SouthGradyWay,Renton,WAg8057-rentonwa.gov ComcastJobJT#184666Page2of2January5,2018likelythattherewillbeundergroundingintheforeseeablefuture;and,whenthereareexistingoverheadelectricalorcommunicationfacilitiesthatwillnotberemovedandthefacilitiesthatwouldhavebeenrequiredtoberemovedareparalleltothefacilitiesthatwiflnotberemoved.DECISION:Therequestedexemptionfromundergroundutilityinstallationrequirements(RMC4-6-090(C)asrequestedbytheapplicantisapprovedsubjecttotheconditionsbelowastherequestcomplieswithexemptioncriteriaofRMC4-6-090(D)(1)(g)iandii.ConditionsofApproval:1.Anyexistingheightviolationswouldneedtoberesolvedatthetimeofconstruction.Newaerialfibermusthaveaminimumverticalclearanceof15’-6”.2.Anyabandonedorunusedcablewouldneedtoberemovedatthetimethatconstructionistakingplace.3.Thetrafficcontrolplanrequiresseparateapproval.4.Theaerialfiberwillberequiredtobeinstalledundergroundinthefuturewhenotherutilitiesareundergrounded.Thisdecisiontogranttheexemptionwithconditionsissubjecttoafourteen(14)dayappealperiodfromthedateofthisletterperRMC4-8-110.AnyappealsoftheadministrativedecisionmustbefiledwiththeCityClerk,alongwiththerequiredappealfee,by5:00pm,January19,2018.Sincerely,Ow*óth’fJenniferT.Henning,AICPPlanningDirectorcc:CE.“chip”vincent,CEDAdministratorGreggZimmerman,wAdministratorBrianneBannwarth,DevelopmentEngineeringManagerJustinJohnson,civilEngineerIIScottwarlick,EngineeringspecialistIIHollyPowers,DevelopmentServicesRepresentativePatMiller,constructionInspectionSupervisorJoshBlakeslee,SEFNcO,lblakesleeasefnco.comStefaniaSpencer,SEFNcO,sspencer(&’sefnco.comFranchisePermits1055SouthGradyWay,Renton,WA98057rentonwa.gov