HomeMy WebLinkAboutP_TCP_268018_171213_v1COMCAST
JT# 268018_
AERO PLASTICS
903 Houser Way N
Renton, WA 98057
PROJECT MAP:
THIS IS PROPRITORY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED CANNON CONSTRUCTION
CONTACTS:
Pat Gottbreht - 360-888-3211
Pgottbreht@cannonconstructioninc.com
COMCAST
Kyle Kinney - 253-235-7016
Kyle_Kinney@cable.comcast.com
AERO PLASTICS
Mike Brown - 425-226-3400
SCOPE OF WORK:
-TIE IN @ CASE: KV07MX1.5A.1A.1A (SP.WAKV.0128)
-DIRECTIONAL BORE (1) 4" CONDUIT
-PLACE FIBER IN EMPTY
-PLACE NEW (3) 24"X36" VAULT
-PLACE NEW (1) 14"X17" LANDSCAPE VAULT
-OPEN TRENCH ACROSS ROAD
-PLACE 2" EMT & PULL FIBER IN EMPTY
BILL OF MATERIALS':
96 CT FIBER: 625 FT + 20% STORAGE = 750 FT
36 CT FIBER: 210 FT + 20% STORAGE = 252 FT
PROJECT DESCRIPTION*
NEW AERIAL = 0 FT.
OVERLASH = 0 FT.
NEW UNDERGROUND = 625 FT.
EXISTING UNDERGROUND = 0 FT.
RISER (0) = 0 FT.
TOTAL FOOTAGE = 625 FT.
PROJECT DESCRIPTION*
NEW BUILDING PATH WAY = 210 FT.
EXISTING BUILDING PATHWAY = 0 FT.
NEW UNDERGROUND = 0 FT.
EXISTING UNDERGROUND = 0 FT.
TOTAL FOOTAGE = 210 FT.
TOTAL PROJECT FOOTAGE = 835 FT.
*ALL FOOTAGES AND MATERIALS ARE ESTIMATED
SHEET INDEX:
1
- COVER SHEET
2
- OVERVIEW
ell
- DESIGN
5-6
- SITE DETAILS
7-11
- TRAFFIC CONTROL PLANS
NE Park Dr
Lowe's Ha e
3
�
p
Improve me t
s
Stnev�a
Can -rete
nsymR�'
The Reserve Apartmutts
903 Houser V iay North
qac rQ
Five Guys �
I Green Planet
Sanctuary Apartments
�
N
od BEc uEl
1
Tcrer4 s Mexican > TT
The Landing Panda Express
s
Distant Lands Trading Co
R
Fry's Electronics
THIS IS PROPRITORY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED CANNON CONSTRUCTION
CONTACTS:
Pat Gottbreht - 360-888-3211
Pgottbreht@cannonconstructioninc.com
COMCAST
Kyle Kinney - 253-235-7016
Kyle_Kinney@cable.comcast.com
AERO PLASTICS
Mike Brown - 425-226-3400
SCOPE OF WORK:
-TIE IN @ CASE: KV07MX1.5A.1A.1A (SP.WAKV.0128)
-DIRECTIONAL BORE (1) 4" CONDUIT
-PLACE FIBER IN EMPTY
-PLACE NEW (3) 24"X36" VAULT
-PLACE NEW (1) 14"X17" LANDSCAPE VAULT
-OPEN TRENCH ACROSS ROAD
-PLACE 2" EMT & PULL FIBER IN EMPTY
BILL OF MATERIALS':
96 CT FIBER: 625 FT + 20% STORAGE = 750 FT
36 CT FIBER: 210 FT + 20% STORAGE = 252 FT
PROJECT DESCRIPTION*
NEW AERIAL = 0 FT.
OVERLASH = 0 FT.
NEW UNDERGROUND = 625 FT.
EXISTING UNDERGROUND = 0 FT.
RISER (0) = 0 FT.
TOTAL FOOTAGE = 625 FT.
PROJECT DESCRIPTION*
NEW BUILDING PATH WAY = 210 FT.
EXISTING BUILDING PATHWAY = 0 FT.
NEW UNDERGROUND = 0 FT.
EXISTING UNDERGROUND = 0 FT.
TOTAL FOOTAGE = 210 FT.
TOTAL PROJECT FOOTAGE = 835 FT.
*ALL FOOTAGES AND MATERIALS ARE ESTIMATED
SHEET INDEX:
1
- COVER SHEET
2
- OVERVIEW
3-4
- DESIGN
5-6
- SITE DETAILS
7-11
- TRAFFIC CONTROL PLANS
DIRECTIONAL BORE
(1) 4" CONDUIT &
PULL 96CT FIBER
IN EMPTY
t
r 4
PLACE NEW
24"X36" VAULT
TIE IN @ CASE:
KV07MX1.5A.1 A.1 A
(SP.WAKV.0128)
LEAVE 200'
96ct STORAGE
96ct
PLACE NEW
24"X36" VAULT
6' OPEN TRENCH ACROSS
TO PRIVATE PROPERTY
PLACE NEW
14"X17" VAULT
PLACE NEW 2" & V
PULL 36CT FIBER 36ct
IN EMPTY
2ND FLOOR +
SERVER ROOM'
• �L
96ct
PLACE NEW
24"X36" VAULT
NEW SPLICE LOCATION
TRANSITION FROM 96CT-
36CT ONTO PRIVATE
PROPERTY
AERO PLASTICS 158018
903 Houser Way N
Renton WA 98057
DATE REVISION BY Qc
12-11-2017 DG P6
li
CO M C A S T CANNON CONSTRUCTION INC.
Overview 2 O F 11
HULL 9(jU I FIBER
IN EMPTY
0
96ct
TIE IN @ CASE:
KV07MX1.5A.1 A.1 A
(SP.WAKV.0128)
LEAVE 200'
STORAGE
2
dpi
d0
PLACE NEW b
24"X36" VAULT
R
AERO PLASTICS 268018
903 Houser Way N
Renton, WA 98057
DATE REVISION I BY QC
T2- 1 -Ml
DG F6
COMCAST
Design
CANNON CONSTRUCTION INC.
3 OF11
m°9
m°
q
m
m
o
°
dpi
10
dpa
a° dpi
PLACE NEW 2" &
PULL 36CT FIBER
IN EMPTY
2ND FLOOR
SERVER ROOM
DIRECTIONAL BORE
(1) 4" CONDUIT & \ G
PULL 96CT FIBER
IN EMPTY \
\
0
OPEN TRENCH ACROSS
TO PRIVATE PROPERTY
PLACE NEW
14"X17" VAULT
2A0
903
NEW SPLICE LOCATION
TRANSITION FROM 96CT-
36CT ONTO PRIVATE
PROPERTY
dpi
EpP
d0�
d
W
O
w
96ct
PLACE NEW
24"X36" VAULT
AERO PLASTICS 2680181
1 903 Houser Wav N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG PG
COMCAST
Design -2
CANNON CONSTRUCTION INC.
4 OF11
r
CORE DRILL 2" HOL-
IN EXTERIOR WAL I
& PLACE L.E
PLACE NEW 2" CONDUIT
N1 36CT FIBER IN E n A
PLACE 2' EMT &
PULL 36CT FIBER
IN EMPTY
suml
RFA
A
PLACE NEW 14"X17"
LANDSCAPE VAULT
OPEN TRANCH ACROSS FOR NEW SPLICE
ROAD TO PRIVATE PROPERTY CASE
& PLACE 36CT FIBER IN EMPTY
!PLACE!EMPTY
CORE DRILL 2"
4
AERO PLASTICS 268018
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG P6
1las -
CO M C A S T CANNON CONSTRUCTION INC.
SITE DESIGN T 5 OF11
IN
IN
I.
7r
s
PLACE 2' EMT &
PULL 36CT FIBER j
IN EMPTY
,4
i
I
!PLACE!EMPTY
CORE DRILL 2"
4
AERO PLASTICS 268018
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG P6
1las -
CO M C A S T CANNON CONSTRUCTION INC.
SITE DESIGN T 5 OF11
PLACE 2' EMT &
PULL 36CT FIBER
IN EMPTY
CORE DRILL Z
PLACE 2' EMT &
PULL 36CT FIBEk
IN EMPTY
CUSTOMER SERVER
RACK ON OTHER SIDE
OF WALL
1
a
4C!ORE DRILL 2"
PLACE 2' EMT &
PULL 36CT FIBEP
IN EMP7
_ ..............
-
- g
�' 9 1• _
S �
CUSTOMER SERVER
RACK ON OTHER SIDE '
OF WALL
9
LEAVE 50' COIL
FOR RACK MOUNT
TERM PANEL t
,1
e P�7
N
AERO PLASTICS 268018
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG PG
1las -
CO M C A S T CANNON CONSTRUCTION INC.
SITE DESIGN 6 OF11
SITE SPECIFIC TRAFFIC CONTROL PLAN
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILLNOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO
ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL
WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF
THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND
ANY SPECIAL CONDITIONS EXIST
UT un
WORK
AHEAD
b \�
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH
1500'
RURAL HIGHWAYS 60/65 MPH+/
-
RURAL ROADS 45/55 MPH
500' +/-
RURAL ROADS & URBAN ARTERIALS 35/ PH
350' +/-
RURAL ROADS & URBAN ARTERIAL
25/30 MPH
RESIDENTAL & BUSINESS DIS TS
200'+/-
URBAN STREETS 25 MPH OR LESS
100'+/
00'+/4LL
NILLSIGNS AR "x48" BLACK ON ORANGE UNLESS OTHERWISE DES
1) ALL SIG ACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,
NTER IONS AND DRIVEWAYS.
E SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
IVIII1411VIUIVI 1141r-11 LC1141,a 11'7 1114 rCC 1 = L
LANEPOSTED SPEED LIMIT (MPH)
WIDTH 25 30 35 40 45 50 55 60 65 70
LONGITUDINAL BUFFER SPACE = B
SPEED 25 30 35 40 45 50 55 60 65 70
LENGTH 155 200 250 305 360 425 495 570 780 840
\ ***Note*** -Will coordinate
with business that will be
effected by construction
-Will have TCS on site to
escort pedestrian though work
zone.
- All work will stop to escort
pedestrians through work
zones.
AERO PLASTICS 268018
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG PG
,t -
CO M C A S T CANNON CONSTRUCTION INC.
TCP 7 OF11
SITE SPECIFIC TRAFFIC CONTROL PLANT
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO
ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL
WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF
THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND
ANY SPECIAL CONDITIONS EXIST
S
�3
925
\ 11-k
b
0
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH
1500'1, T-))
RURAL HIGHWAYS 60/65 MPH+/
-
RURAL ROADS 45/55 MPH
500'+/ -
RURAL ROADS & URBAN ARTERIALS 35/ PH
3501+/ -
RURAL ROADS & URBAN ARTERIAL
RESIDENTAL &BUSINESS DIS TS 25/30 MPH
200'+/-
URBAN STREETS 25 MPH OR LESS
100'+/ -
ALL SIGNS AR 'x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATE
(1) ALL SIG ACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTER IONS AND DRIVEWAYS.
Ll�E SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
MINIMUM TAPER LENGTH IN FEET - L
LANE POSTED SPEED LIMIT (MPH)
25 30 35 40 45 50 55 60 65 70
10 105 150 205 270 450 500 550 - -
11 115 160 225 295 495 550 605 660 -
12 125 180 245320 540'1600166017201780 840
LONGITUDINAL BUFFER SPACE = B
SPEED 25 30 35 40 45 50 55 60 65 70
LENGTH 155 200 250 305 360 425 495 570 780 840
***Note*** -Will coordinate
with business that will be
effected by construction
-Will have TCS on site to
escort pedestrian though work
zone.
- All work will stop to escort
pedestrians through work
zones.
N
AERO PLASTICS 268018
b b
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG I PG
1
COMCAST
TCP
CANNON CONSTRUCTION INC.
8 OF11
SITE SPECIFIC TRAFFIC CONTROL PLAN
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO
ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL
WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF
THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND
ANY SPECIAL CONDITIONS EXIST
a\R
a
851
E�
0
III
III
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH
1500' +
RURAL HIGHWAYS 60/65 MPH
RURAL ROADS ROADS 45/55 MPH
500'
RURAL ROADS & URBAN ARTERIALS 35/ PH
350'+/ -
RURAL ROADS & URBAN ARTERIAL
25/30 MPH
RESIDENTAL & BUSINESS DIS TS
200' +/-
URBAN STREETS 25 MPH OR LESS
100'+/ -
ALL SIGNS AR 'x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIG ACING MAV BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTER IONS AND DRIVEWAYS.
E SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
b b MINIMUM TAPER LENGTH IN FEET = L
LANE POSTED SPEED LIMIT (MPH)
W1DTH 25 30 35 40 45 50 55 60 65 70
10 105 150 205 270 450 500 550 - - -
11 115 160 225295 495 550 605 660 - -
12 125 180 245 1320 540 6001660j 720 780 840
0
P�pPO �,LaSF
S C` SES
`NNEpO
P
LONGITUDINAL BUFFER SPACE = B
SPEED 25 30 35 40 45 50 55 60 65 70
LENGTH 15,51200125013051360 1425 1495 1570 1780 1840
***Note*** -Will coordinate
with business that will be
effected by construction
-Will have TCS on site to
escort pedestrian though work
zone.
- All work will stop to escort
pedestrians through work
zones.
b
N
AERO PLASTICS 268018
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
711-2017 DG PG
COMCAST
TCP
CANNON CONSTRUCTION INC.
9 OF11
SITE SPECIFIC TRAFFIC CONTROL PLAN
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO
ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL
WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF
THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND
ANY SPECIAL CONDITIONS EXIST
0
0
N
0
851
%\R
El
b
poi
b
III
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH
1500' +
RURAL HIGHWAYS 60/65 MPH+/
-
RURAL ROADS 45/55 MPH
500' +/-
RURAL ROADS & URBAN ARTERIALS 35/ PH
350' +/-
RURAL ROADS & URBAN ARTERIAL
25/30 MPH
RESIDENTAL & BUSINESS DIS TS
200' +/-
URBAN STREETS 25 MPH OR LESS
100'+/ -
ALL SIGNS AR "x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIG ACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, ATGRADE
INTER IONS AND DRIVEWAYS.
( E SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
MINIMUM TAPER LENGTH IN FEET = L
LANE POSTED SPEED LIMIT (MPH)
WIDTH 25 30 35 40 45 50 55 60 65 70
10 105 150 205 270 450 500 550 - - -
11 115 160 225 295 495 550 605 660 - -
12 125 180 245 320 540 600 660 720 780 840
LONGITUDINAL BUFFER SPACE = B
SPEED 25 30 35 40 45 50 55 60 65 70
1 1 LENGTH 155 200 250 305 360 425 495 570 1780 840
b
***Note*** -Will coordinate
with business that will be
effected by construction
-Will have TCS on site to
escort pedestrian though work
zone.
- All work will stop to escort
pedestrians through work
zones.
N
0
AERO PLASTICS 268018
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG PG
COMCAST
TCP
CANNON CONSTRUCTION INC.
10OF11
II SITE SPECIFIC TRAFFIC CONTROL PLAN
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO
ADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROL
WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF
THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND
ANY SPECIAL CONDITIONS EXIST
***Note*** -Will coordinate
with business that will be
effected by construction
-Will have TCS on site to
escort pedestrian though work
zone.
- All work will stop to escort
pedestrians through work
zones.
�\R
L�R
903
851
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH
1500' +
RURAL HIGHWAYS 60/65 MPH+/
-
RURAL ROADS 45/55 MPH
500' +/-
RURAL ROADS & URBAN ARTERIALS 35/ PH
350'+/ -
RURAL ROADS & URBAN ARTERIAL
25/30 MPH
RESIDENTAL & BUSINESS DIS
200'+/-
URBAN STREETS 25 MPH OR LESS
100' +/-
ALL SIGNS AR "x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIG ACING MAYBE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, ATGRADE
INTER IONS AND DRIVEWAYS.
( E SPACING MAYBE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
MINIMUM TAPER LENGTH IN FEET = L
I
POSTED SPEED LIMIT (MPH)
25 30 35 40 45 50 55 60 65 70
105 150 205 270 450 500 550 - - -
115 160225 295 495 550 605 660125 180 245 320 540 600 660 720 780 840
LONGITUDINAL BUFFER SPACE = B
$ SPEED 25 30 35 40 45 50 55 60 65 70
s
LENGTH 155 200 250 305 360 425 495 570 780 840
b
A
30 �
8
O
b
P
Q L R
o�
N
kp
s 0 2
0
AERO PLASTICS 268018
903 Houser Way N
Renton WA 98057
DATE REVISION BY QC
12-11-2017 DG PG
COMCAST
TCP
CANNON CONSTRUCTION INC.
11 O F 11