Loading...
HomeMy WebLinkAboutMFP17000393DEPARTMENTOFCOMMUNITYANDECONOMICDEVELOPMENT0FranchisePermit:MFP17000393IVRNumber:17000393PermitInformationContactsBillingTypeNameAddressPhone____________XContactAttn:SteveLeVeck1000DennyWay,#400Level3-BillingSeattle,WA98109OwnerKarlRoller1055SGradyWayB:(425)430-6851CityofRentonRenton,WA98057-3232C:(425)430-6931GeneralConditions&SignaturePermitName:Level3ConnumicationsAddress/Location:4444NESUNSETBLVDParcelNumber:0323059282ApplicationDate:01/24/2017PermitType:FranchiseIssueDate:01/24/2017PermitWorkClass:MajorUtilityExpirationDate:01/24/2018FranchiseType:CableJobNumber:AdelphiaSewEst.Completion:02/28/2017Description:Opentrench-i-is20’coordinatingwithCitytorepairsewerdamageuponcompletionofrepairfilltrenchandrestoresurface.NOTE:Onsitepreconrequired.Pleasecall72hourspriortoschedule.PROJECTNAME:AdelphiaSewerRepair.•Permissionisherebygivenfortheworkdescribedonthispermitaccordingtotheconditionshereonandaccordingtotheapprovedplansandspecificationspertainingthereto,subjecttocompliancewiththeOrdinanceoftheCityofRenton.•Thispermitandplansmustbepostedatthejobsiteatalltimes.•Iherebycertifythatnoworkistobedoneexceptasdescribedaboveandinapprovedplans,andthatworkistoconformtoRentonTrenchRestorationandStreetOverlayRequirements•Call(425)430-7203orgoto:www.MyBuildingPermit.comoneworkingdayinadvancetoscheduleaninspectionsandforANYworkintheRightofWay.•Call811tolocateundergroundutilitiesatleasttwofullbusinessdayspriortoanyexcavation•InaccordancewithRCW19.122.033(4)thepermitholderisrequiredtocontact(WilliamsNorthwestPipelineat425.868.1010)(OlympicPipelineat206.510.0575)(PugetSoundEnergyat425.457.5816)torequestaconsultationwiththetransmissionpipelinecompanypriortoperforminganyconstructionorexcavationactivities.ThisrequirementtoconsultwiththetransmissionpipelinecompanyisinadditiontotherequirementtoCallbeforeYouDigasrequiredinRCW19.122.(Signature)(Date)THISPERMITANDPLANSMUSTBEPOSTEDATTHEJOBSITEATALLTIMESPage1of2 ADDRESS:NESUNSETBLVD&ANACORTESAVENE,RENTONWA,98105CONTACTSLEVEL3CONTACT:KRISHNAMITCHELL1000DENNYWAY,SUITE400SEATTLEWA,98109C303.378.2759KRISHNA.MITCHELL@LEVEL3.COMTYLERBURTONMGCTECHNICALCONSULTING,INC.8521154THAVENEREDMOND,WA98052C.425.615.0567TYLER@MGCTECHNICAL.COMSHEETINDEX1.COVERSHEET/SITELOCATION2.LEGEND3.GENERALNOTES4.PLANVIEWA5.TYPICALS6.SITEPHOTOGRAPHSSCOPEOFWORK:OPENTRENCH40’EAST&WESTFROMWORKAREAATTHENWCORNEROFNESUNSETBLVD&ANACORTESAVENE.COORDINATEWITHTHECITYOFkENTONTOHAVESEWERDAMGEREPAIREDWHILETRENCHISINPLACE.UPONCOMPLETIONOFSEWERREPAIRTRENCHTOBEFILLED,ANDSURFACEREPAIREDPERCITYOFRENTONSTANDARDS.Knowwhatsbelow.Callbeforeyoudig.0250500SCALE:1“=500’3AS—BUILT2REVISION1101/05/17TBKLORIGINALNODATEENGINEERDRAFTERCOMMENTLevel(3Y[McCIUUICATtUCLEVEL3ENGINEERKRISHNAMITCHELLENGINEERINGFIRMMGCTECHNICALCONSULTINGINCPROJECTNUMBERADELPHIALOCATIONNESUNSETBLVD&ANACORTESAVENERENTONWA,98105DRAWINGNAMELSVEL3.ADECPHIA.PLANSdw0PROJECTNAME:ADELPHIASEWERREPAIRSITELOCATIONCONFIDENTIAL/PROPRIETARYSHEET1OFDO LEGENDUGFIBER—EXISTINGUGFIBER—PROPOSEDAERIALFIBER—EXISTINGAERIALFIBER—PROPOSEDSTRAND—EXISTINGSTRAND—PROPOSEDCONDUIT—EXISTINGCONDUIT—PROPOSEDINNERDUCT—EXISTINGINNERDUCT—PROPOSEDGASWATERTELEPHONEELECTRICSANITARYSEWER(SEW)STORMDRAINFENCECABLEIVSTEAMOILUNKNOWNUTILITYRIGHTOFWAYEDGEOFPAVEMENTFDPNAMESIZELOCATIONNAMESIZELOCATIONNAMESTREETPOLEAUACHMENTCALLOUT—EXISTINGUSEDYNAMICPULLDOWNTOSELECTFROM1TO6AUACHMENTSPOLEATTACHMENTCALLOUT—PROPOSEDUSEDYNAMICPULLDOWNTOSELECTFROM1TO6ATTACHMENTSCABLESPANCALLOUT—EXISTINGFORUSEONPAPERSPACE(SHOWNAT50X)CABLESPANCALLOUT—PROPOSEDFORUSEONPAPERSPACE(SHOWNAT5OX)CONDUITCALLOUT—EXISTINGFORUSEONPAPERSPACE(SHOWNAT5OX)WITHORWITHOUTINNERDUCTINFOCONDUITCALLOUT—PROPOSEDFORUSEONPAPERSPACE(SHOWNAT50X)WITHORWITHOUTINNERDUCTINFOSTRANDCALLOUT—EXISTINGFORUSEONPAPERSPACE(SHOWNAT50X)STRANDCALLOUT—PROPOSEDFORUSEONPAPERSPACE(SHOWNAT50X)0RISERTELEPHONEPOWERVAULTCATCHBASIN/INLETFIREHYDRANTTRANSMISSION/DISTRIBUTIONTRANSMISSIONLINJYPES____—B———B—________—B———B—____AA—I—I——I————————————I—II—I—WTESEW-SDxxTVSTMOIL•UNK•R/WEOPPOLENON/AUTILITi’lIPOLENON/AUTIUTY1IO•_OoDISTRIBUTIONHi’GROUND/BONDSTREETLIGHTTREE—<CULVERTN/WINGWALL[BRIDGE©MISC.UTILITYVAULT—VAULT—EXISTINGVAULTOWNERVAULT-VAULT—PROPOSEDE2VAULTOWNER0’‘EJAERIALSTORAGE—EXISTING0’AERIALSTORAGE—PROPOSEDVAULT/BUILDINGSTORAGE—EXISTINGVAULT/BUILDINGSTORAGE—PROPOSEDPOLEANCHOR/DOWNGUY—EXISTING(POLEANCHOR/DOWNGUY—PROPOSED—0<DOWNGUYTOEXISTINGANCHOR—PROPOSED®OWNERUTILITYPOLE—EXISTINGSYMBOLDESCRIPTIONID0ASWASPHALTSIDEWALKOWNERPOLE—PROPOSEDIDBIPBLACKIRONPIPEHH—BSPBLACKSTEELPIPECSWCONCRETESIDEWALKHANDHOLEHANOHOLE—EXISTINGOWNEREOPEDGEOFPAVEMENTHHEOWIEDGEOFTRAVELWAYFOCFACEOFCURBHANDHOLEHANDHOLE—PROPOSEDOWNERHDPEHIGHDENSITYPOLYETHYLENEMH—HHHANDHOLEjMANHOLEMANHOLE—EXISTINGlBJUNCTIONBOXOWNERMHMANHOLEMHMPMILEPOSTMANHOLEMANHOLE—PROPOSED0/sOFFSETOWNERPRPOWERRISERp3—PVCPOLYVINYLCHLORIDEPULLBOXPULLBOX—EXISTINGRGSRIGIDGALVANIZEDSTEELCONDUITOWNERROWRIGHTOFWAYPBSTA.STATIONPULBOX—PROPOSEDPULLBOXOWNERTERMINATION—EXISTINGTERMINATION—PROPOSEDBUILDINGCALLOUT—PROPOSEDCABLEFIBERS:FIBERSCABLEOWNER:OWNERCABLELENGTH:LENGTHNOTES:CABLEflBERS:FiBERSCABLEOWNER:OWNERCABLELENGTH:LENGTHNOTES:CONDUrIOWNER:OWNERCONDUITLENGTH:LENGTHCONDUIIOW:CONDUITSCONDUITSIZE:SIZECONDUITTYPE:TYPEINNERDUCT0ThINNERDUCTSINNERDUCTSIZE:SIZEINNERDUCTTYPE:TYPENOTES:CONDUITOWNER:OWNERCONDUITLENGTH:LENGTHCONDUITOW:CONDUITSCONDUITSIZE:SIZECONDUITTYPE:TYPEINNERDUCT011:INNERDUCTSINNERDUCTSIZE:SIZEINNERDUCTTYPE:TYPENOTES:STRANDTYPE:TYPESTRANDLENGTH:LENGTHNOTES:STRANDTYPE:TYPESTRANDLENGTH:LENGTHNOTES:Knowwhalsbelow.Callbeforeyoudig.MANUFACTURERSPLICEPOINT—EXISTINGNAMEMANUFACTURERNAMESPLICEPOINT—PROPOSEDI#FIN:0SEQUENTIALCALLOUTLOUT:0L_#FINDISEQUENTIALINTAILCALLOUTTAIL:olI4TAIL:0SEQUENTIALTAILOUTCALLOUTL‘OUT:03AS—BUILT2REVISIONN1I01/05/17TB(CORIGINALNODATEENGINEERDRAFTERCOMMENTLevel(3)c•CMNuN1CAT1D5LEVEL3ENGINEERKRISHNAMITCHELLENGINEERINGFIRMMGCTECHNICALCONSULTINGINCPROJECTNUMBERADELPHIALOCATIONNESUNSETBLVD&ANACORTESAVENERENTONWA,98705DRAWINGNAMELEVEL3-AOELPHIA-PLANSdw8CONFIDENTIAL/PROPRIETARYSHEEt2OF08 GENERALNOTESGENERALNOTES:Thelocationsofutilitiesshownonthesedrawingareonlyapproximate.MGCTECHNICALCONSULTING,INC.herebydisclaimsanyresponsibilitytothirdpartiesfortheaccuracyofthisinformation.PersonsworkingintheareacoveredbythisdrawingmustcontactthestatewideCall-Before-You-DigSystemtoascertainthelocationofundergroundutilitiespriortoperforminganyexcavation.1.ALLMATERIALS,WORKMANSHIP,ANDCONSTRUCTIONOFUTILITYIMPROVEMENTSSHALLMEETOREXCEEDSITEWORKSTANDARDSANDTHESTANDARDSANDSPECIFICATIONSSETFORTHINTHECITYOFRENTONREGULATIONSANDAPPLICABLESTATEANDFEDERALREGULATIONS.WHERETHEREISCONFLICTBETWEENTHESEPLANSANDTHESPECIFICATIONS,ORANYAPPLICABLESTANDARDS,THEHIGHERQUALITYSTANDARDSHALLAPPLY.ALLWORKWITHINPUBLICROW.OREASEMENTSMAYREQUIREINSPECTEDANDAPPROVEDBYTHECITYOFRENTONINSPECTOR.INSPECTIONSERVICESANDCONSTRUCTIONCERTIFICATIONTOBEPROVIDEDBYDESIGNEEOFPROJECTSPONSOR/OWNER.2.THECONTRACTORISSPECIFICALLYCAUTIONEDTHATTHELOCATIONAND/ORELEVATIONOFEXISTINGUTILITIES,ASSHOWNONTHESEPLANS,ISBASEDONRECORDSOFTHEVARIOUSUTILITYCOMPANIESAND,WHEREPOSSIBLE,MEASUREMENTSTAKENINTHEFIELD.THEINFORMATIONISNOTTOBERELIEDUPONASBEINGEXACTORCOMPLETE.THECONTRACTORMUSTCALLTHELOCALUTILITYLOCATIONCENTERATLEAST48HOURSBEFOREANYEXCAVATIONTOREQUESTEXACTFIELDLOCATIONSOFEXISTINGUTILITIES.THECONTRACTORSHALLVERIFYPERTINENTLOCATIONSANDELEVATIONS,ESPECIALLYATTHECONNECTIONPOINTSANDATPOTENTIALUTILITYCONFLICTS.ITSHALLBETHERESPONSIBILITYOFTHECONTRACTORTORELOCATEALLEXISTINGUTILITIESTHATCONFLICTWITHTHEPROPOSEDIMPROVEMENTSSHOWNONTHESEPLANS.3.THECONTRACTORSHALLBERESPONSIBLEFOROBTAININGALLNECESSARYPERMITSFROMALLAPPLICABLEAGENCIES.THECONTRACTORSHALLNOTIFYTHECITYOFRENTONINSPECTORATLEAST48HOURSPRIORTOTHESTARTOFANYEARTHDISTURBINGACTIVITYORCONSTRUCTIONONANYANDALLPUBLICIMPROVEMENTSIFREQUIRED.4.THECONTRACTORSHALLCOORDINATEANDCOOPERATEWITHTHECITYOFRENTONANDALLUTILITYCOMPANIESWITHREGARDTORELOCATIONSORADJUSTMENTSOFEXISTINGUTILITIESDURINGCONSTRUCTION,TOASSURETHATTHEWORKISACCOMPLISHEDINATIMELYFASHION,ANDWITHAMINIMUMDISRUPTIONOFSERVICE.THECONTRACTORSHALLBERESPONSIBLEFORCONTACTINGALLPARTIESAFFECTEDBYANYDISRUPTIONOFANYUTILITYSERVICE.5.THECONTRACTORSHALLHAVEONE(1)SIGNEDCOPYOFTHEAPPROVEDPLANS,ONE(1)COPYOFTHEAPPROPRIATESTANDARDSANDSPECIFICATIONS,ANDONE(1)COPYOFANYPERMITSANDEXTENSIONAGREEMENTSNEEDEDFORTHEJOBON-SITEATALLTIMES.6.THECONTRACTORSHALLBERESPONSIBLEFORALLASPECTSOFSAFETYINCLUDING,BUTNOTLIMITEDTO:EXCAVATION,TRENCHING,SHORING,TRAFFICCONTROL,ANDSECURITY.7.IF,DURINGTHECONSTRUCTIONPROCESS,CONDITIONSAREENCOUNTEREDBYTHECONTRACTOR,HISSUBCONTRACTORS,OROTHERAFFECTEDPARTIESWHICHCOULDINDICATEASITUATIONTHAIISNOTIDENTIFIEDINTHEPLANSORSPECIFICATIONS,THECONTRACTORSHALLCONTACTTHEENGINEERIMMEDIATELY.8.ALLREFERENCESTOANYPUBLISHEDSTANDARDSSHALLREFERTOTHELATESTREVISIONOFSAIDSTANDARD,UNLESSSPECIFICALLYSTATEDOTHERWISE.9.FORWORKAFFECTINGPUBLICROADWAYSORIFREQUIREDBYTHECITYOFRENTON,THECONTRACTORSHALLSUBMITATRAFFICCONTROLANDPHASINGPLANINACCORDANCEWITHM.U.T.C.D.FORAPPROVAL.PRIORTOANYCONSTRUCTIONACTIVITIESWITHINORAFFECTINGTHERIGHT-OF-WAY,THECONTRACTORSHALLBERESPONSIBLEFORPROVIDINGANYANDALLTRAFFICCONTROLDEVICESASMAYBEREQUIREDBYSAIDPLANS.PRIORTOINSTALLATIONAPRECONSTRUCTIONCONFERENCESHALLBEHELDVV1THCITYOFRENTON.10.THECONTRACTORISRESPONSIBLEFORPROVIDINGALLLABORANDMATERIALSNECESSARYFORTHECOMPLETIONOFTHEINTENDEDIMPROVEMENTSSHOWNONTHESEDRAWINGSORDESIGNATEDTOBEPROVIDED,INSTALLED,CONSTRUCTED,REMOVEDORRELOCATEDUNLESSSPECIFICALLYNOTEDOTHERWISE.11.PERAGENCYSTANDARDSTHECONTRACTORSHALLBERESPONSIBLEFORKEEPINGROADWAYSFREEANDCLEAROFALLCONSTRUCTIONDEBRISANDDIRTTRACKEDFROMTHESITE.12.THECONTRACTORSHALLBERESPONSIBLEFORRECORDINGRECORDINFORMATIONONASETOFRECORDDRAWINGSKEPTATTHECONSTRUCTIONSITEANDAVAILABLETOTHECITYOFRENTONINSPECTORATALLTIMES.13.DIMENSIONSFORLAYOUTANDCONSTRUCTIONARENOTTOBESCALEDFROMANYDRAWING.FORADDITIONALINFORMATIONCONTACTTHEENGINEERFORCLARIFICATIONANDNOTEONTHERECORDDRAWINGS.3AS—BuILT14.ALLEROSIONANDSEDIMENTCONTROL(E.S.C.)MEASURESSHALLBEINSTALLEDATTHELIMITSOFCONSTRUCTIONPRIORTO01/05/17TBKLREVION1GROUNDDISTURBINGACTIVITY.ALLE.S.C.MEASURESSHALLBEMAINTAINEDINGOODREPAIRBYTHECONTRACTORUNTILSUCHDATEENGINEERDRAFTERCO4ENTTIMEASTHEENTIREDISTURBEDAREASARESTABILIZEDWITHHARDSURFACEORLANDSCAPING.________KnowwhatsbelOW.15.ALLWORKWITHINTHEPUBLICRIGHT-OF-WAYISSUBJECTTOTHEJURISDICTIONOFTHECITYOFRENTONENGINEERINGCallbeforeyoudig.3DEPARTMENTSTANDARDDETAILSANDSPECIFICATIONS.CbMMUNICAIIOUSLEVEL3ENGINEERKRISHNAMITCHELL16.ALLCONSTRUCTIONOPERATIONS,INCLUDINGTHEWARMINGUP,REPAIR,ARRIVAL,DEPARTUREORRUNNINGOFTRUCKS,EARTHENGINEERINGFIRMMGCTECHNICALCONSULTINGINCMOVINGEQUIPMENT,CONSTRUCTIONEQUIPMENTANDANYOTHERASSOCIATEDEQUIPMENTSHALLGENERALLYBELIMITEDTOTHEPROJECTNUMBERADELPHIATIMEPERIODAPPROVEDBYTHECITYOFRENTON.LOCATIONNESUNSEEBLVD&ANACORTESAVENERENTONWA,98105DRAWINGNAME-LEVEL3-AOELPHIA-PLANSdwgCONFIDENTIAUPROPRIETARYSHEET3OF06 PLANVIEWAKnowwhatsbelow.Callbeforeyoudig.2pcrAlF1’=30’CONSTRUCTIONNOTESWORKAREAFORDAMAGEDCITYOFRENTONSEWERLINETOBEREPAIRED.OPENTRENCHAPPROXIMATELY40EASTANDWESTOFWORKAREATOEXPSEEXISTINGLEVEL3DUCT.PROJECTNOTES•COORDINATEWITHCITYTOMINIMIZETIMETHATTRENCHNEEDSTOBEOPENFORSEWERREPAIRS.•TRENCHTOREMAINOPENWHILESEWERLINEISBEINGREPAIRED.STEELPLATESWILLNEEDTOBEPLACEDOVERTRENCHDURINGNON-WORKHOURS.•UPONCOMPLETIONOFSEWERREPAIRCLOSETRENCHANDREPAIRSURFACEPERCITYOFRENTONSTANDARDS.SYMBOLCORRESPONDSTOPHOTOLOCATIONSANDORIENTATIONSEESHEET#06FORSITEPHOTOGRAPHS3AS—BUILT2REVISION1101/05/17TBKLORIGINALNODATEENGINEERDRAFtERCOMMENTLEveIt3YtLEVEL3ENGINEERKRISHNAMITCHELLENGINEERINGFIRMMGCTECHNICALCONSULTINGINCPROJECTNUMBERADELPHIALOCATIONNESUNSETBLVD&ANACORTESAVENERENTONWA,98105DRAWINGNAMELEVEL3-AOECPHIA-PLANSdw5SHEET4OF06CONFIDENTIAUPROPRIETARY LONGITUDINALBUFFERSPACE=BSPEED(MPH)25303540455055606570LENGTH(FEET)155200250305360425---PROTECTIVEVEHICLEWITHTMAROLLAHEADDISTANCETYPICALPROTECTIVETYPICALPROTECTIVEVEHICLESTATIONARYVEHICLETYPEWITH(WTHTMA)LOADEDWEIGHTOPERATIONTMA(LBS)(FEET)4DDUMMINIMUMWEIGHT15000LBS.SERVICETRUCK(MAXIMUMWEIGHTSHALLBEIN30MIN.FLATBEDETCACCORDANCEV’IITHMANUFACTURER100MAX.,.RECOMMENDATION)ROLLAHEADSTOPPINGDISTANCEASSUMESDRYPAVEMENT6APROTECTIVEVEHICLEISRECOMMENDEDREGARDLESSIFATMAISAVAILABLE.IFNOTMAISUSED,THEPROTEC]1VEVEHICLESHALLBESTRATEGICALLYLOCATEDINTHEFIELDTOSHIELDWORKERSANDNOROLLAHEADDISTANCEISSPECIFIED.W20-1xi/fW20-4X//W2o____+/i-ilwç’/9:1IFREEWAYS&EXPRESSWAYS55/70MPHRURALHIGHWAYS60/65MPH800+1-RURALROADS45/55MPH600+/-RURALROADS&URBANARTERIALS35/40MPH350+/-RURALROADS,URBANARTERIALS25/30MPH200+1-(2)RESIDENTIAL&BUSINESSDISTRICTSURBANSTREETS25MPHorLESS100’+1-(2)ALLSIGNSARE48”x48BLACKONORANGEUNLESSOTHERWISEDESIGNATED.(1)Allspacingmaybeadjustedtoaccommodateinterchangeramps,at-gradeintersections,anddriveways.LANECLOSURE(F01?MULTI-LANE1?OADWAY(2)Thisspacingmaybereducedinurbanareastofitroadwayconditions.NOTES1.PROTECTIVEVEHICLERECOMMENDED-MAYBEAWORKVEHICLE.2.SEESPECIALPROVISIONSFORWORKHOURRESTRICTION.3.RECOMMENDEXTENDINGDEVICETAPER(L13)ACROSSSHOULDER.4.DEVICESSHOULDNOTENCROACHINTOADJACENTLANES.5.USETRANSVERSEDEVICESINCLOSEDLANEEVERY100025/(RECOMMENDED).6.TRAFFICSAFETYDRUMSRECOMMENDEDFORALLTAPERSONHIGHSPEEDROADWAY.7.WHENUSED,DEVICESPACINGFORTHEDOWNSTREAMTAPERSHOULDBE20’O.C.8.SPOTTERONSITETOESCORTPEDESTRIANSTHROUGHWORKZONE.9.ADVANCEWARNINGSIGNSARETOGEPLACEDONALLAPPROACHESWHENANINTERSECTIONISWITHINTHETRAFFICCONTROLZONE.SEETABLESFORSIGNSPACINGDISTANCES.0__FJEHEI.tSIGNALTOBESETTOFOUR—WAYREDFLASHINGMODE______IL—OFFICERREQUIREDWHEN—WORKINGININTERSECTION_iz_.5---.-5.1111UHUtiir17W20-1$TLaneWidthPostedSpeed(mph)(feet)2530354045505560657010105150205270450500550---11115165225295495550605660--12125180245320540600660720780840CN_3IAS—BUILT2IREVISION/$11]01/12/17TBXLORIGINALNO1DATEENGINEERDRAFTERCOMMENTLevel(3YIcCUICATI)SLEVEL3ENGINEERKRISHNAMITCHELLENGINEERINGFIRMMGCTECHNICALCONSULTINGINCPROJECTNUMBERADELPHIALOCATIONNESUNSEIBLVD&ANACORTESAVENERENTONWA,98105DRAWINGNAMELEVEL3.ADELPHIA-TCPsdwgW20-lwlO-5R4rx4r4tX48BUFFERDATASIGI\/LEGEiVDSIGNLEGENDICHANNELIZINGDEVICESPACING(FEET)IMPHiTAPERTANGENT50/704080II30I6025/302040W4-2R48X4V1615W20—4W20—74rx4r4Vx4t/7—PLACESIGNATNEARESTINTFRSPCTION1aG22OSSWALKSIDEWALKCLOSEDCLOSEDRQ—3XCR9—936”x24’Wx24i[IDAIKCLOSEDAHEADJCROSSHERC20—2S.36X18RI—ha30x24G20-7.÷1R9-11——S.—..S+•_____•_•___•_•—:_____riL[IIU1-.(NNESUNSETBLVDW20-1W20-7txx-..W4-2R..W20-5RW20-1/H’H’LEGENDSIGNSPACING=X(FEET)W20-1SIGNLOCATIONANDSIGNNUMBERN’W12-1ORSEQUENTIALARROWPANELCHANNELIZINGDEVICESPROTECTIVEVEHICLE(RECOMMENDED)AFLAGGERORSPDOFFICERFORCONTROLLEDINTERSECTIONG20-2SCOPEOFWORKUSEWORKZONETOBOREANDTRENCHCONDUITS,PLACEHANDHOLESANDPULLFIBERCABLETHROUGH.STREETUSEPERMITif:TBDBYCITYHOURS:TBDBYCITYTRAFFICCONTROLPLAN#01-USESET-UPWHEREAPPLICABLEALONGNESUNSETBLVD(SOUTHBOUNDLANE)MINIMUMTAPERLENGTH=L(feet)Keyswhat’sbelow.Callbeforeyoudig.CONFIDENTIAMPROPRIETARYSHET01OF51 City—1ir©iriiDEPARTMENTOFCOMMUNITYANDECONOMiCDVELOPMENTDEVELOPMENTSERVICESDIVISIONResterjLseparatior)ñ-mCityUtjgtMASTERUSE/FRANCHISEUTILITYPERMITAPPLICATION-aWIthin2weeksOfcompjPhone:t425)430-7266Fax:(425)430-7231franchise@rentonwa.govTOTHEAPPLICANT:Submit3copiesofplanswithapplication.Permitcostis$360.50.Inspectionfeefortrenchingmorethan60linealfeetorinstallationof6ormorepoleswillbebilledat$60.00perhour.ForCityUseOnlyCITYPERMITNO:l’1P(7o-ti—iWORKORDERNO.:1.18.17FranchiseAgency:LEVEL3DateofApplication:_________________________________________________________________MailingAddressforPermit:1000DENNYWAYSTE400,SEATTLEWAZip:98109ContactName:KRISHNAMtTCHELLPhone303.378.2759JobNumber:ADELPHIASEWERREPAIRt-J-mai.KRISHNA.MITCHELL@LEVEL3.COML-s5t11i4(JobSiteAddress:NESUNSETBLVD&ANACORTESAVENhProjectName:ADELPHIASEWERREPAIROPENTRENCH+/-80’COORDINATINGWITHCITYTOREPAIRSEWERDAMAGEDescriptionofWork:UPONCOMPLETIONOFREPAIRFILLTRENCHANDRESTORESURFACE.Pleasecheckatlthatapply:(-t2-t/?re-Cc,üNewConstructionRepair/RelocateUndergroundUOverheadSidewalkStreetOpentrenchUBoreUIIoffeet:UGasUElectricUOther:EstimatedJobcompletiondate:TBDContractorname:IBDPhone:TBDCityofRentonBusinessLicenseNumber:StateContractorsLicenseNumber:___________________________“IcertifythatIamtheapphicnt’sownerorauU)orizedagentanddoherebyagreetoabidetothetermsandconditionssetforthunderthispermitandshallcc’mpIywiththeit:bf.Renton’sTrenchRestorationandStreetOverlayRequirements.Signature_________________________________________Date1.18.17CITYINSPECTORSHALLBENOTIFIED24HOURSPRIORTOCOMMENCEMENTOFALLWORKBYCALLINGTHEINSPECTIONLINEAT425-430-7203Jobsarerequiredtobecoiledinforjobstart,re-inspectionandprojectfinal._____________________________________UApprovedasSubmittedPlanIçvw/DevelopmentServicesDateRequired1).-UApprovedwithCommentsorRedtinesC/’..__..I-L{Zt7TrafficControlPlanAttachedUtilityInspectorDateUCameraInspectionofJtihtieIRequired__________________________________________IssueDate:JAN24?t)1PublicWorksPermitSupervisorDatePermitexpires6mq95m1ssuedate2/1! TRAFFICCONTROLPLANPROJECTNAME:LEVEL3-ADELPHIASEWERREPAIRPERMIItt______________CONSTRUCTIONCOMPANY:TBDPHONE#:______________CONTACTNAME:KRISHNAMITCHELLPHONE#:720.387.3342ADDRESS:1000DENNYWAY,SUITE400SEATTLEWA,98109CELL#:303.378.2759E-MAILADDRESS:KRISHNA.MITCHELL@LEVEL3.COMFAX#:________________NESUNSETBLVD&ANACORTESAVENEPROJECTLOCATION:RFNTONWA,gfl5N/E/S/WOF:____________________WORKTIME:—4-u‘330APPROVEDBY:-PØ,(Qi_—WORKDATE:__________________________APPROVALDATE:_______________PermitHolderagreestoallthefollowing:•ComplywithalltrafficregulationsoftheCityofRentonandtheStateofWashington.•PrepareatrafficcontrolplanandobtainCityapprovalofthatplan.Thatplanshallbeimplementedforallstreetandlaneclosures,andtheplanshallbeperformedincompliancewiththeManualonUnformTrafficControlDevices.•Notifyemergencyservices(253-852-2121)twenty-four(24)hoursbeforeanystreetorlaneclosures.•AnylaneorStreetclosuresnotinconformancewiththeapprovedtrafficcontrolplanand/orwithoutnotificationofemergencyservicesmayresultinreceivingacitationforviolationofR.C.W,47.36.200through47,36.220,9A.36.050RecklessEndangerment,andotherapplicableStateandCitycodes.-IndemnifyandholdharmlesstheCityofRentonfromanyandallclaims,actions,andjudgments,includingallcostsofdefenseandattorney’sfeesincurredindefendingagainstsame,arisingfromandrelatedtoimplementationoftheapprovedtrafficcontrolplansincludingclaimsarisingfromtowingofprivatevehiclesandtheactsofthePermitHolder’sagentsandemployees.•TheCityofRentonshaTlbeentitled,initsreasonablediscretion,tosettleclaimspriortosuitorjudgment,andinsucheventshallindemnifyandholdharmlesstheCityforanysuchclaimspaid,includingtheCity’sreasonableattorney’sfeesandlitigationcostsincurredresultingfromsuchclaim.•IntheeventanyclaimorsuitisbroughtagainstCitywithinthescopeofthisAgreement,PermitHolderwillpayforlegalcounselchosenbytheCitytodefendagainstsame.•FlaggerandsignplacementaresubjecttorevisionbytheCityInspectoronsite,ifneededtoaddresstrafficorpedestriansafetyortravel.•Bymysignatureherein,Iacknowledgealltheaboverequirements.PRINTNAME:4’if)1.c/1ttDATE:SIGNATURE:..,/I’OFFICECOPYICONTR4CTOR0EV.SERVICE.INSPECTIONP.MILlER0EV.SERViCE,PLANREVIEW8.8’NNWARTHPOLICECHARLESKARLEWICZFIREFIREMARSHALLPS8137 NOTES:•WorkZoneTrafficControlshallbeinaccordancewiththeManualonUniformTrafficControlDevices(MUTCD)andshownbysketchorreferencetoWSDOT.•TheplanmustbesubmittedtotheCity’sPW/TransportationDivisionforreviewand/orapprovalatleastthreeworkingdayspriortowork.•ApprovedTemporaryTrafficControlPlanmustbeattheworksiteduringworkhours.•ContractororentitymustcallRentonSchoolDistrict(425-204-4455)oranypublic/privateagencytobeaffectedbyatemporarylaneorroadclosure.•Completeassistanceandaccommodationshallbeprovidedtoallkindsofpedestriantrafficwhensidewalkorwalkwayisimpeded.•Totalroadclosurelastingmorethan24hoursissubjecttotheapprovalbytheCityCouncil.•Anyvehicle,equipment,barricade,orportabletow-awaysignusedwithintheworkareamustdisplayacompanylogooranylegallyacceptablesignshowingthecompanyname,address,andtelephonenumberataconspicuousplaceonthevehicleorequipment.InthecaseofTemporaryNoParkingZones,allthefollowingapplyinadditiontoprevious:•ContractormustcompleteformtoshowlimitsofTemporaryNoParkingZoneidentifyingbarricadelocationsforvacateparkingorcurblaneusage.•ContractormustpostnoticeofdatesandtimeofTemporaryNoParkingZonewithatleasttwosignsperblock72hoursinadvanceofeffectivedateandtime.•ThecoversheetofthisTrafficControlPlanformmustbeattachedtoeachTemporaryNoParkingSignontheprojectsite.•Temporarytrafficcontroldevicesmustberemovedimmediatelywhenworkisdoneornoconstructionactivitiesaregoingon.Ifdeemedabandoned,CitycrewswillremoveandstorethemattheCity’smaintenanceshop(3555NE2Street).SKETCH--NORTH--