HomeMy WebLinkAboutS-401201N
T
0
i
W
z
LU
0
rQ
V
J_
rr
LU
G
10 5 0 10 20
SCALE IN FEET
KEY NOTES:
DETAIL/
KEY
NOTE:
SHEET
0
PROTECT EX GREASE
INTERCEPTOR, MUST REMAIN IN
-
SERVICE DURING CONSTRUCTION
OTRANSFORMER
LOCATION,
COORDINATE WITH PSE
-
ADJUST EX JBOX TO FINISHED
GRADE. VAULT COVERS SHALL
WITH DOWNTOWN
COR STD
OCOMPLY
STREETSCAPE STANDARDS. SEE
PLAN 102.1
VAULT COVER NOTES ON SHEET
C09.
EX JUNCTION BOX AND
OPROTECT
ADJUST TO FINISHED GRADE
-
UG ELECTRICAL SERVICE TO
OTRANSFORMER.
ROUTING IS
APPROXIMATE- SEE PSE DRAWING
#101113708
EX 1 1/2" WATER SERVICE HAS
O6
BEEN INACTIVE FOR SEVERAL
YEARS PER COR (ACCOUNT NO
-
000743-000). ABANDON EX SERVICE
AND SALVAGE METER TO COR
07
EX PSE VAULT TO REMAIN
-
LIGHTING JUNCTION BOX
OSTREET
8
AND CONDUIT (TYP)
E1.0-E4.0
OREMOVE
CLEANOUT AND CAP EX
SSS AT BACK OF CURB
-
STA 2+12.89,
REPLACE EX SIDE SEWER FROM
CLEANOUT TO BUILDING AND ANY
PORTION THAT IS NOT 6" DIA PVC.
SS1/C14
10
CONTRACTOR TO POTHOLE EX SSS
(COR STD
AND NOTIFY ENGINEER IF 2.00%
PLAN 403.1)
SLOPE FROM BUILDING PLUMBING
CONNECTION CANNOT BE
MAINTAINED
6" IE ±37.50 AT BUILDING
11
RETIRE EX GAS SERVICE AT MAIN,
COORDINATE W/ PSE
-
REMOVE EX FIRE SERVICE VAULT
AND INTERIOR PIPING INC. 1"
12
DOMESTIC SERVICE. RETURN 1"
-
METER TO CITY
WA2/C 12
13
FIRE HYDRANT ASSEMBLY
(COR STD
PLAN 310.1)
ADJUST EX JBOX TO FINISHED
14
GRADE
15
REMOVE EX CLEANOUT
-
3" DOMESTIC SERVICE
CONNECTION. REQUIRED DCVA
WA1/C12,
LOCATED INSIDE BUILDING.
WA3/C12
16
POTHOLE EX GAS MAIN PRIOR TO
(COR STD
TRENCHING FOR WATER SERVICE
PLAN 300.1,
AND NOTIFY ENGINEER IF THERE IS
320.4)
A CONFLICT WITH METER VAULT
A5
17
6" FIRE SERVICE CONNECTION.
STD
(C STD
DDCVA LOCATED INSIDE BUILDING
PLAN
STANDPIPE FIRE DEPARTMENT
18
CONNECTION. 3.0' CLEAR (MIN)
-
REQUIRED IN ALL DIRECTIONS
WA5/C 13
19
FIRE LINE POST INDICATOR VALVE
(COR STD
PLAN 360.5)
LEGEND:
CONCRETE SIDEWALK
ASPHALT PAVEMENT
1 2" IRRIGATION SERVICE TO BE
INSTALLED BY CITY FORCES.
CONTRACTOR SHALL PROVIDE ALL
EXCAVATION AND EXPOSE THE
20
WATER MAIN AND ALSO DIG THE
TRENCH FOR THE NEW SERVICE
WA7/C18
(COR STD
LINE FROM THE MAIN TO THE
PLAN 320.2)
METER. DCVA TO BE LOCATED IN
WATER/FIRE ROOM. IRRIGATION
SERVICES WILL IRRIGATE PRIVATE
PROPERTY AND STREET TREES
21
EX STREET LIGHT TO BE REMOVED
EC1.0-EC4.0
AND REPLACED
22
PROTECT EX WATER SERVICE
-
23
STA 2+34.71
NEW GAS SERVICE AND METER,
-
COORDINATE WITH PSE
SS2/C14,
STA 1+28.18
24
NEW 6" SSS @ 2.00% MIN SLOPE,
STD
(COR STD
W/ NEW CONNECTION TO MAIN
PLAN
6" IE ±37.50 AT BUILDING
406.0
0
NEW SSCO #1
STD
(COR STD
RIM TO FINISHED GRADE
PLAN
26
STREET LIGHTING CONDUIT (TYP)
E1.0 - E4.0
27
NEW SSCO #2
STD
STD (COR
RIM TO FINISHED GRADE
PLAN
28
±25 LF 6" DI PIPE
-
STA 2+20.40, 9.45' LT
WA1/C12,
29
12" X 6" TAPPING TEE (MJxFL) 6"
TAPPING VALVE (FLxMJ)
WA4/C13
(COR STD
W/ CONIC THRUST BLOCK
PLAN 300.1,
±25 LF 6" DI PIPE TO HYDRANT
330.2)
STA 2+26.82, 9.45' LT
WA1/C12,
12" X 4" TAPPING TEE (MJxFL)
WA4/C13
30
4" TAPPING VALVE (FLxMJ)
(COR STD
W/ CONIC THRUST BLOCK
PLAN 300.1,
+27 LF DI PIPE TO METER
330.2)
STA 2+30.29, 9.45' LT
WA1/C12,
31
12" X 6" TAPPING TEE (MJxFL) 6"
TAPPING VALVE (FLxMJ)
WA4/C13
(COR STD
W/ CONIC THRUST BLOCK
PLAN 300.1,
±40 LF 6" DI PIPE TO PIV
330.2)
PLUG EX 6" VALVE WITH 6" PLUG
32
(MJ) BY CITY FORCES.
CONTRACTOR TO EXCAVATE AND
-
RESTORE ROADWAY. CAP EX 6"
SERVICE DOWNSTREAM OF VALVE
22.5 OR 45 DEG BEND W/ CONIC
WA4/C13
BLOCKING PER COR STD PLAN
WA6/C13
33
330.2. BEND LOCATION AND ANGLE
(COR STD
TO BE FIELD DETERMINED IN
PLAN 330.2,
ORDER TO ACHIEVE CLEARANCE
330.3)
FROM EX UTILITIES
22.5 OR 45 DEG BEND W/ CONIC
WA4/C13
BLOCKING PER COR STD PLAN
WA6/C13
34
330.3. BEND LOCATION AND ANGLE
(COR STD
TO BE FIELD DETERMINED IN
PLAN 330.2,
ORDER TO ACHIEVE CLEARANCE
330.3)
FROM EX UTILITIES
ELECTRICAL DUCT BANK (NOT
35
SURVEYED- LOCATION IS
-
APPROXIMATE)
CENTURYLINK DUCT BANK (NOT
36
SURVEYED- LOCATION IS
-
APPROXIMATE)
CONIC THRUST BLOCK FOR 4", 90
37
DEG BEND
DOMESTIC METER BYPASS POST
38
INDICATOR VALVE
UTILITY AND RESTORATION NOTES:
WATER METER VAULT 1. PAVEMENT RESTORATION SHALL MEET THE CITY OF RENTON STANDARD
TRENCH AND STREET OVERLAY STANDARDS.
2. UNDERGROUNDING OF ALL UTILITIES IS APPLICABLE.
3. MINIMUM VERTICAL SEPARATION BETWEEN UTILITIES AT CROSSING IS 12
` ' LANDSCAPE INCHES. CROSSINGS LESS THAN 12 INCHES REQUIRE ETHAFOAM
BLOCKING.
4. CONTRACTOR TO POTHOLE EX GAS MAINS AT LOCATION OF PROPOSED
UTILITY CROSSING
# STORM DRAIN, SIDE SEWER AND WATER SERVICE CROSSINGS AND
SEE TABLE THIS SHEET REPORT TO ENGINEER IF CROSSINGS AS SHOWN ARE NOT FEASIBLE.
BASE MAP/TOPOGRAPHY PROVIDED BY
Gqe
OTHERS. DCG CANNOT BE HELD LIABLE
9706 4th Ave NE
Suite
Seattle, WAA 98115
o�NoFW
\� f'ga ne
C9 �Ison Ti
-
belei
FOR ACCURACY. CONTRACTOR SHALL
FIELD VERIFY GRADES, UTILITIES AND
ALL OTHER EX FEATURES &
P: 206.523.0024
F: 206.523.1012
www.dcgengr.com
e: Q:�
�0� RFoiaT6�0 8
�`SS/ONAL '
CONDITIONS. IF CONDITIONS ARE NOT
AS SHOWN &/OR PLANS CANNOT BE
CONSTRUCTED AS SHOWN, CONTACT
DCG PRIOR TO CONSTRUCTION.
2
C❑NSTRUCTI❑N RECORD DRAWINGS
CT
01/08/20
1
P❑ST-PERMIT REVISI❑N- UTILITY C❑NFLICT
CT
01/25/19
NO.
REVISION
BY
DATE
CONSTRUCTION RECORD DRAWING:
THIS SHEET CONTAINS AS -BUILT INFORMATION. MINOR
REVISIONS ARE SHOWN BY STRIKING THROUGH THE ORIGINAL
TEXT AND DENOTING THE AS -BUILT INFORMATION ADJACENT.
OTHER REVISIONS ARE DENOTED BY REVISION CLOUDS.
AS -BUILT INFORMATION WAS SURVEYED BY D.R. STRONG AND
SUPPORTING PHOTOS AND DOCUMENTATION WAS PROVIDED
BY SRM (CONTRACTOR). DCG IS REPONSIBLE FOR NOTATING
THE AS -BUILT INFORMATION ON THE DRAWINGS BUT IS NOT
RESPONSIBLE FOR THE ORIGINAL AS -BUILT DATA PROVIDED
TO DCG.
SURVEYED:
SCALE:
AS NOTED
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
DESIGNED:
CT
DRAWN:
RB/CT
ONE INCH
CHECKED:
TG
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
P P R
APPROVED:
TG
CB, SOLID LID
TOP=39.52
I.E. 8"PVC(N)=36.
I.E. 8"PVC(S)=36.
30LID LID
=39.43
r'PVC(N)=35.8
r'PVC(S)=35.8
3"PVC(W)=35.18
IH, TOP=39.34
S"PVC(E)=35.2
3"PVC(S)=35.1
3"PVC(N)=35.1
OR TOP=39.89
_L OF WATER,
ES NOT VISIBLE
R. CHNL.(N-S)=35.4
{, TOP=38.84
. 8"CONC(W)=37.3
1, TOP=39.36
CONC(E)=37.4
PVC(W)=36.9
>."CONC(S)=35.3
2"CONC(N)=35.1
11-1FU 1 LU I
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
Aomttk C TY OF
MERRILL GARDENS AT RENTON CENTER- ADDITION
%R1waoR E N TO N 104 BURNETT AVE S, RENTON, WA 98057
Planning/Building/Public Works Dept. COMPOSITE UTILITY PLAN
1 /8/20
PAGE:
DRAWING NO:
C06
SHEET: 6 OF: 34
CU
z
LU
0
Q
0
J_
LU
G