Loading...
HomeMy WebLinkAboutR-401204z LU rQ V J J_ Fr LU G 5 P-21 10 5 0 10 20 SCALE IN FEET KEY NOTES: DETAIL/SH KEY NOTE: EET INSTALL APPROX 430 LF SILT EC1/C10, FENCE OR STRAW WATTLES. EC2/C10 0 PERIMETER RUNOFF CONTROL (COR STD PLAN MUST BE PROVIDED AT PROPERTY 213.40, 214.00) BOUNDARIES TEMPORARY CHAIN LINK CONSTRUCTION FENCING WITH O HIGH VISIBILITY OR PRIVACY - FABRIC PANELS INSTALL TEMPORARY INLET PROTECTION ON EX SD INLET OR EC4/C11 O CLOSEST SD INLET DOWNSTREAM (COR STD PLAN OF SITE. INLETS SHALL BE 216.30) CLEANED OF ANY CONSTRUCTION DEBRIS AS REQUIRED. INSTALL TEMPORARY STABILIZED CONSTRUCTION ENTRANCE. EC3/C10 40 CONSTRUCTION ENTRANCE NOT (COR STD PLAN REQUIRED TO BE INSTALLED IF EX 215.10) ASPHALT REMAINS O EX BUILDING AND PARKING AREA TO BE DEMOLISHED - CONTRACTOR TO SWEEP STREET DAILY OR MORE OFTEN IF O NECESSARY TO REMOVE TRACKED - SEDIMENT 07 EX TREE TO BE REMOVED - WINTER GRADING NOTE: FROM OCTOBER 1 TO APRIL 30, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN 2 DAYS. FROM MAY 1 THROUGH SEPTEMBER 30, NO SOILS HALL REMAIN EXPOSED FOR MORE THAN 7 DAYS. ADJACENT PROPERTIES SHALL BE PROTECTED FROM SEDIMENT OR STORMWATER RUNOFF BY VEGETATIVE BUFFER STRIPS, SEDIMENT BARRIERS, FILTERS, BERMS OR OTHER SUITABLE METHOD TO ENSURE THEIR PROPERTY IS NOT DAMAGED CITY OF RENTON WET SEASON EROSION CONTROL MEASURES SHALL BE FOLLOWED FROM OCTOBER 1ST TO APRIL 30TH. GENERAL TESC NOTES AND RECOMMENDED CONSTRUCTION SEQUENCE: SEE SHEET C10 LEGEND: �m CONSTRUCTION ENTRANCE X SILT FENCE OR STRAW WATTLES HVF TEMPORARY CHAIN LINK CONSTRUCTION FENCING NOTE: NO DEWATERING IS PROPOSED. NOTIFY GEOTECHNICAL ENGINEER IF SITE CONDITIONS DIFFER AT TIME OF CONSTRUCTION. SEE GEOTECHNICAL RECOMMENDATIONS SUMMARY ON SHEET C18- PROJECT CONDITIONS. PERIMETER RUNOFF CONTROL SHALL BE PROVIDED AT PROPERTY BOUNDARIES. DUST CONTROL MEASURES SHALL BE IMPLEMENTED AS NECESSARY. n-401201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS WE CALL 811 (2) BUSINESS DAYS z BEFORE YOU DIG LU BASE MAP/TOPOGRAPHY PROVIDED BY (UNDERGROUND UTILITY pC W. G4 OTHERS. DCG CANNOT BE HELD LIABLE LOCATIONS ARE APPROXIMATE) < 9706 4th Ave NE �o�� of ed FOR ACCURACY. CONTRACTOR SHALL SURVEYED: SCALE: DATE: Suite 300 Tim® VERTICAL: NAVD 1988 • 1 /8/20 1 Seattle, WA 98115 on FIELD VERIFY GRADES, UTILITIES AND DESIGNED: AS NOTED HORIZONTAL: NAD 1983/1991 o C TY OF MERRILL GARDENS AT RENTON CENTER- ADDITION 8 J elein ALL OTHER EX FEATURES & CT — R E N TO N 104 BURNETT AVE S, RENTON, WA 98057 PAGE: P: 206.523.0024 �"► 01 CONDITIONS. IF CONDITIONS ARE NOT 2 C❑NSTRUCTI❑N REC❑RD DRAWINGS CT 01/08/20 DRAWN: PAGE: F: 206.523.1012 0 4,Ir AS SHOWN &/OR PLANS CANNOT BE RB/CT ONE INCH • DRAWING N0: CIS CONSTRUCTED �G� 1 P❑ST—PERMIT REVISION— UTILITY CONFLICT CT 01/25/19 CHECKED: TG IF NOT ONE CNCH DATUM Planning/Building/Public Works Dept. TESC PLAN C04 W www.dcgengr.com Fss� CONSTRUCTED AS SHOWN, CONTACT ONAL DCG PRIOR TO CONSTRUCTION. NO. REVISION BY DATE 1APPj APPROVED: TG SCALE ACCORDINGLY SHEET: 4 OF: 34