HomeMy WebLinkAboutS-401202N T C) I W I— U) Z LU 0 rr Q J_ Ir LU 2 RECESSED LIFT POCKET O-1/2" 11" —� 12-1 f4"� CAST IRON RINQ AND Not to Scale FRAME 91-nrI nw>Lrrro 1��1,1 1 NOTLSi_ 1. 8" AND 6" CLEAN -OUT RINGS AND COWERS ON SEWER MAINS SHALL BE EAST JDRDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00369803) DR APPROVED EQUAL, CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS, POUR A 1'-0" THICK, 2'-D" SQUARE CONCRETE, CLASS 30120, PAD AROUND THE RING AND COVER. OR DABLE CLEANOUT STD_ PLAIN - 403.1 ~ PUBLIC WORKS 8" OR f" CLEANOUT APPROVED; DEPARTMENT FOR SANITARY SEWER MAIN YA Gn!A it n ti 0"hnc 4Y9 H n n� � 8" OR 6" CLEANOUT FOR SANITARY SEWER MAIN SS1 NOT TO SCALE C06 ,4 W. G 9706 4th Ave NE O of WAsf Suite 300 �/1 Digi Seattle, WA 98115 C) P: 206.523.0024 r F:206.523.1012 �0 47202 www.dcgengr.com AONAL BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE ed FOR ACCURACY. CONTRACTOR SHALL y FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & in CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN &/OR PLANS CANNOT BE 8'00 CONSTRUCTED AS SHOWN, CONTACT DCG PRIOR TO CONSTRUCTION. 47 BEND AS REQUIRED (NCI MARE THAN 45• BEND.). EVERY RND CHANGE IN DIRECTION OR GRADE WILL REQUIRE A SURFACIE CLEANOUT WYE. (SEE NOTE 11) H-OUSE 4" CLEANDU T WYE WITH 45' BEND AND PLUG. (SEE NOTE 11) w w J � HOUSE q a d SURFACE CLEANOUT 6"x 6"x6" WYE CSEE STD PLAN -- 407) PRQPERTY LIME -Z I z MAIN SEWER LINE iiiiiihi 4" SURFACE 1 CLEANDUT WYE 4" WYE WITH CLEANGUT UP ALL 9Q' TURNS SHALL BE ACCOMPLISHED - BY MEANS 9F A VVYE MTH CLEANOUT AND 45' BEND. TWO 45' BENDS SHALL NOT BE ACCEPTABLE_ (SEE NOTE 11) 1 Lo 2 HOUSE a_ 3LD" WIN. 4" SEWER PIPE {T'�IOAL} 4" TEST TEE WITH PLUG FACE UP (TYPICAL) j 6"x 4 REDUCER � (TYPICAL) HOUSE 4" SEWER PIPE, SEE NOTES 2 AND 3. MINIMUM LIN£ SIZE FOR OTHER THAN SINGLE FAMILY IS B" PROPERTY ONE NOTES - IF THE BUILDING 5EWER SERVES ANY FIXTURE HAVfNC 1. Pr1ar to lnstallat'on of a sanitary sewer connection, o sfde-sewer x FLOOD LEVEL R1M5 LOCATED BELOW THE ELEVATION psrmlt must tre purchased from the City Qf Rentprl Public Works M M(4" OF THE NEXT UPSTREAM MANHOLE COVER OF THE Depairtment, UPU2LIC SEWER SYSTEM, A BACKFLOW PREVENTION "t7 zDEVICE SUCH AS CLEAN CHECK EXTENDABLE 1 51BACKWATER VALVE Off APPROVED EQUAL S4A�LL G1 2. Types of pipe and fittings that can be used For sanitary sewers INSTALLED. sh❑II be approved l y the Department of Pudic Works. Rubber of neoprene gcskets as specffled by the manufacturer, shall be 4" FLEXIBLE COUPLING (1=ERNCO OR EQUAL) used r�rr joints. J A minimum grade of 29 (1/4"' per toot) must be mcintolned SURFACE CLCLEANOUT3. 4"x 4"x4" WaE with 4" pipe_ In the evient a 27 grade cannot be maintained, the PIPINC owner must sign a City of Renton grade release form and then can install 6` pips of ❑ grade of 1%. PLAN BUILDING DRAIN FOR 4, For inspection of side sewer, call 24 hours in advance_ The LOW ELEVATION HOUSE inspection prone number is on the sfde sewer permik. Site must be ready for inspection on-i representative on sit* when inspector arrives of appointed time. Side sewer an.d stub shall be tested p-er Cfty speefileo#lords. Make the connection at the h D t b kf;ll th 1*;t 11 M1' b th MAIN TO PROPERTY LINE V-0" 5-0 ruse, " no ac I +v I c "INapprorva IS giver. y B PROPERTY LIME FROM THE HOUSE BUILDING DRAIN . inspector. Final approval will be granted after the existing septic SIDE SEWER BUILf]INC SE JFR 2._B., tank has been pumped out ❑nd filled with sand. L TO 3.�0., r 3'-0"MIN. 5. Install side 5uwcr with 2' minimum cover. 18" Gover iz allowed { at the douse if outlet is shallow. 5. It side sewer stub Is not ovoiloble. The owner shall be C"' mrn Ln 41 L r, 1# � responsible for 'its instollat;on per standard drowrnq 405_1. All LJ 1-`,a1 W Z m °' x o x � rn work within street right-af-way sh-all be done by a licensed and oa 0- ^> � C n z nF- 0 4 � m m" z � " - -� 1Ex r1., n rn bonded contractor. rrI Q-Z ran 0 � rn r rn r O C � W C m � x. II Z C)* m 0 ?C r P, 0 z n m � 7. All work shall be accomplished in accordance with the Washington cn-4 r- 0;� LA n r m C -q x. z 0 > n F rrn � rn rn Industrial Safety and Health Att. (VASNA) Z rrcl w 3 rrrl rQ cn0Q = — n, Q b Iti a z 0 I� Va Q S. All french rentoratlon for side sewers in [he puhflc rlqht nt- war 3q. v m a .r. r small conform to the most current trench restarcution C31 a, D - rr1 0 requirement€ as in the Rentoul Skandafd Drawings. �. x to rn - Z Q 0. z n 0 9. All building sewer and side sewers shall have bedding in x" Lao urcordonce with standard druwin.g 405. COCA g Cq -ate rri 10. There shall be n rninfrnurn 10 foot horizontal sepflratibn between rn v O. TI -u sanitrory side sewers and water services and a rnininnurn 5 foot _ horizontal separation between sanitary side sewers and all other rn utlli#ies. 11. Thee cleonoul at the Right -of -Way shall be installed per CALL FOR LOCATIONS KrORE YOU DIG Standard Plan 07. The cleanout of the building shall be 48HR LOCATORS 1-800-424-5555 installed to surface grade. All other cieonouts shall he installed to within 12" of the sur#dce. y TYPICAL BUIL13ING SEWER STD. PLAN— 406.2 `1 PUBLIC AR WORKS FROM LINE TO DEPARTMENT ,# BUILDING CONNECTION AUGUST 2DI3 TYPICAL BUILDING SEWER FROM PROPERTY LINE TO BOLDING CONNECTION rS S 2 NOT TO SCALE C06 EX. SEWER MAIN PROPERTY LINE SPOOL (LENGTH AS INEEOED) Z` � I I 6" 5E11'!ER STUBE FUTURE 4" SIPE SEWER • I 2"x 4" STUD MARKING POST PAINTED SEi' FR MAIN TEE X 5" TEE a" CAMP V41 WA Tl TH THE WORD W SEWER STENCILED IN 3" HIGH ULACK LETTERS AND #6 WIRE z I WRAPPED AROUND THE STUD AND E)(TENDED TO THE TOP OF THE STUD. I i COUPLING (TYP.) t i4 a __T_- ___,-__-_- -- ------,_ r- ----.� L __ _J BEND AS y REQUIRED 6"X,5'X5' SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO, 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID). (SEE STD. PLAN 403.1 FOR INSTALLAT ON) Jib EAGLE THREADED CLEAN --CUB' ADAPTER HUE1 & PLUG (OR APPROVED EQUAL) -LXIST1NG SAAJITARY SEWlER MAIN---2.07- MIN. SLOPE FUTURE 4" SIDE SEWER �B" SEWER 5TLJO 5"K5']t6' WYE FUTURE Vx 4" REDUCER SEWER MAIN SIZE ?(6•, TEE F I A. 'ATRIFIED CLAY MAW - CUT IN A NEW PVC "TEE' USING 'STRONG -BACK' FLEXIBLE COUPLINGS (FERNC❑ OR AIPPROYED EQUAL). B. CONCRETE MAIN - GUT IN A NEW PVC 'TEE" USING "STRONG -BACK- FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC dr C9C0 PVC MAIN - CUT IN NEW TEE: US= RIGID COUPLINGS OR OCRE-()BILLED WTH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPRGVED EQUAL) E. MANHOLE CONNECTION - ALt, CONNILOT1ONS TO MANH%C-S SHALL RE AT MANUFACTURED KNocx-a41T i OR THE STRUCTURE SHALL IBE CORE -DRILLED. 3000 PS mix R CONCRETE +• -�CtiCk low.G 2% M11"_IDPE HORIZONTAL TEE t5" MIN. SEWER SEWER AGAIN VAIN CONCRETE BLOCKING ANGLE NOTE: JISL.ESS OTHERVOSE SHOWN ON PLAN, 51DE SEWER SHALL HAVE A MININfUhI 2.5' CCVER AT PROPEIRT1' UNE OR ]-5' LOWER THAN THE LOWLSt HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER STD. PLAN ,406.1 PUBLIC WORKS�t DEPARTIVIENT INSTALLATIONpw m 41)-c (SEINER MAIN TO PROPERTY LINE) � o�n 0 •ykYc rih�711 STANDARD SIDE SEWER INSTALLATION SS3 NOT TO SCALE �O6 R-401201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS W, CALL 811 (2) BUSINESS DAYS W BEFORE YOU DIG LU (UNDERGROUND UTILITY 12� LOCATIONS ARE APPROXIMATE) < SURVEYED: SCALE: DATE: VERTICAL: NAVD 1988 DESIGNED: 1 /8/20 AS NOTED HORIZONTAL: NAD 1983/1991 C TY OF MERRILL GARDENS AT RENTON CENTER- ADDITION CT C - C FIELDBOOK: DRAWN: RENTON 104 BURNETT AVE S, RENTON, WA 98057 PAGE: Ir 2 C❑NSTRUCTI❑N RECORD DRAWINGS CT 01/08/20 RB/CT • DRAWING No: 1 P❑AT FULL SCALE PanninST-PERMIT REVISION- UTILITY CONFLICT CT 01/25/19 CHECKED: ONE INCH DATUM g/Buidin g/Public Works Dept. CITY DETAILS- SEWER C14 LU TG IF NOT ONE INCH N 0. REVISION BY DATE APPF APPROVED: TG SCALE ACCORDINGLY SHEET: 14 OF 34