N 2" - 6„ HMA .
T (S-EE NOTE 2) 1
Q MIN.
*k 1 I -2" HMA (-SEE NOTE 2)
.2" SAW CU7 AND REMOVE
OR 'LANE, SEAL WITH
AR-400CW
WIDTH OF TRENCH AS REQUIRED BY SIZE OF
PROPOSED IMPROVEMENT (SEE WSDOT
STANDARD SPECIFICAPON 2-a-9_4) PLLIS AN
ALLOWANCE FOR ANY SHORING. SHORING, IF
NEEDED, SHALL MEET THE REQUIREMENTS GF
WSDOT STANDARD SPECIFICATION 7-08.3(1)6
NOTES:
VARIES: 4, 5' MIN,
J
SAWCUT AFTER BACKFILL
DEPTH OF EXISTING PAVEMENT
EDGE OF PAVEMENT, EDGE
1 OF CURB & CUTTER, OR
MIN, CENTER OF LANE MARKING
6" CRUSHED SURFACING TCP COURSE
(CSTC) (9-03-9(3)) PER WSDOT STANDARD
SPECIFCATIONS, COMPACTED TO 95%
M0011FIED PROCTOR
CSTC, BANK RU14 GRAVEL FOR TRENCH BACKFILL
(9-03-19), GRAVEL BORROW (S-03.I4(1)) PER
WEDOT STANDARD SPECIFICATIONS OR NATIVE
MATERIAL IF APPROVED IN VA17ING BY FNGINEER
BASED ON GEOTECH REPORT, CDVPACTED TO
957� MODIFIED PROCTOR.
'-PIPE ZONE BEDDING MATEMAL AND COMPACTION AS
REQUIRED BY THE WSOOT STANDARD SPECIFICATIONS
FOR THE TYPE OF rMPROVEME€VT INSTALLED, EXCEPT:
* FOR STORM AND WATER PIPE, PEP STD PLAN 220_0
* FOR SANITARY SEWED, RER ETD PLAN 405
TRENCH WIDTH * FOR JOINT UTILITY TRENCH, SAND NTH 95%
PASSING A 04 SIEVE AND LESS THAN 5% PASSING
A 0200 SIEVE
1- WHEN EXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BROKEN OR DEI RIOIRATED
TO A PAVEMENT CONDITION INDEX RATING OF 70 OR LESS, THE EXISTINC PAVEMENT IN THAT LANE, AND
FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED M7H 11M4 MATCHING 7HE DEPTH
USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER.
2- PRINCIPAL/ MINOR/COLLECTOR, ARTERIAI_, & INDUSTRIAL ACCESS STREETS - MATERIAL AND THICKNESS
SHALL BE HMA CL J" PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN E.,.
RE&DENTIAL ACCF-SS STREETS -- HMA CL 4- PC 64-22. THE THICKNESS SHALL BE THAT OF THE EXISTING
PAVEMENT SECTION AND IN ND CASE LESS THAN 4".
3- WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LAVE, CURB & CUTTER OR
SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CkJRB &
GUTTER SHALL BF REMOVED AND REPLACED, OR THC SHOULDER SHALL BE PLANED OR REMOVED AND
OVERLAID WITH HMA.
4, IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE
REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT,
5- IF TRENCHING THROUGH EXISThNG DRfVEWAAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL
BE REPLACED TD MEET ADA STANDARDS -
TYPICAL LONGITUDINAL PATCH STD. PLAN - 110A
19 filf
PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR
DEPARTMENT RIGID PAVEMENT WITH [OVERLAY
TYPICAL LONGITUDINAL PATCH FOR FLEXIBLE
PAVEMENT OR RIGID PAVEMENT WITH OVERLAY RD7
9706 4th Ave NE
Suite 300
Seattle, WA 98115
P: 206.523.0024
F: 206.523.1012
www.dcgengr.com
NOT TO SCALE C09
W.
OFF
I,
G9 on Z
elein
<< .01
G�s6:��, G`
ONAL
BASE MAP/TOPOGRAPHY PROVIDED BY
OTHERS. DCG CANNOT BE HELD LIABLE
FOR ACCURACY. CONTRACTOR SHALL
FIELD VERIFY GRADES, UTILITIES AND
ALL OTHER EX FEATURES &
CONDITIONS. IF CONDITIONS ARE NOT
AS SHOWN &/OR PLANS CANNOT BE
CONSTRUCTED AS SHOWN, CONTACT
DCG PRIOR TO CONSTRUCTION.
2
C❑NSTRUCTI❑N RECORD DRAWINGS
CT
101108120
1
P❑ST-PERMIT REVISI❑N- UTILITY C❑NFLICT
CT
01/25/19
N0.
REVISION
BY
DATE
SURVEYED: SCALE:
VERTICAL: NAVD 1988
AS NOTED HORIZONTAL: NAD 1983/1991
DESIGNED:
CT
DRAWN:
RB/CT ONE INCH DATUM
CHECKED: AT FULL SCALE
TG IF NOT ONE INCH
P I R APPROVED: SCALE ACCORDINGLY
TG
1-1/2" AND 2" WATER S5g&f11C`iE1 bt- iAlL
CAUTION: VALVE BOX SHOULD NOT REST ON
PIPE. LATER COMPACTION IN AREA OF VALVE BOX
COULD CAUSE THE BREAKAGE OF THE SERVICE.
CITY
PIPING
�z
}
IN UNIMPROVED
r
RIGHT-OF-WAY INSTALL METER
a
BOX AT PROPERTY LINE WITH
a
0
12" LONG COPPER TAILPIECE
0
o_
o_
9" MIN.
12" MAX.
Z X X
o o , LEAVE EXPOSED o
,fin U 4 7 (U M N C) U 12"
BY PASS NOT ALLOWED
0� FOR IRRIGATION METERS
U \�/ '-CRUSHED ROCK
BASE TO SUPPORT
A _ /� VAULT.
/ "� DRILL 2" HOLE FOR
TOUCHREAD DEVICE QUICK -JOINT
COUPLING x MIPT CAST IRON OR DUCTILE IRON WATERMAIN
2-1/2" MIN. FROM NEAREST NOTE:
AND FRONT EDGE OF PIT LID THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM
UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS
THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF
MORE THAN ONE RIB.
TYPICAL RIB
MATERIAL LIST FOR 2" SERVICE: METER LOCATED IN PLANTING STRIP
BETWEEN CURB & SIDEWALK
1. 2" tapped tee, on new water main.
2. 4" long X 2" brass nipple with threaded ends (MIPT).
3. 2" resilient seat gate valve with threaded ends, square operating nut,
and valve nut extension if required (see standard detail 330.1).
4. Two piece cast iron valve box. Standard 8" top section with regular
base section, length to fit, "lug" type cover. 2" brass bushing (MIPT x
I�tFtT).
5. each 2" brass or bronze nipples 6" length, threaded ends. 2 each
2"-90' brass or bronze elbows (FIPT x FIPT).
6. 2" (MIPT) x compression fitting, Ford C84-66 or equal.
7. 2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to
fit.
8. 2" threaded brass 90° ell.
9. 2" Customsetter with by-pass Ford: VBH 86-12B-11-77 (x 17-3/16"
), McDonald Brass: 30B715WDFF775 or Mueller B-1427-2", with flanged
angle ball valve and padlock wings on inlet, and angle check valve
outlet, ball valve on bypass with padlock wings. Customsetter shall
have vertical inlet and outlet.
10. Rigid meter spreader to be supplied and installed in Mg, er setter by
contractor.
11, -Woter r.me$er shall be supplied and installed by, ,,City, off' Renton upon
pgynen,t��di all related water meter fee and safirsfackory,jp'ressure and
purity tests.
12. 17"x30" Plastic meter box equal to Mid -States Plastics, Inc. BCF Series
MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x3l"
equal to Mid -States Plastics, Inc. MSCBC-1730-R with 2" drilled hole
for touchread pit lid, and meter read lid.
13. 2" coupling (compression x FIPT) with 2" plug (MIPT), Ford C-14-66
or equal. The property owner is responsible for any necessary adaptation or
extension of water service.
NOTE:
ALL METER BOXES INSTALLED IN CONCRETE OR PAVED
DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC
FOUNDARY.
EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH
SIDES OF METER BOX.
PRIVATE
PIPING
MATERIAL LIST FOR 1-1/2" SERVICE: METER LOCATED IN PLANTING STRIP
BETWEEN CURB & SIDEWALK
1. 2" tapped tee on new water main.
2. 4" long X 2" brass nipple with threaded ends (MIPT).
3. 2" resilient seat gate valve with threaded ends, square operating nut, and
valve nut extension if required (see standard detail 330.1).
4. Two piece cast iron valve box. Standard 8" top section with regular base
section, length to fit, "lug" type cover.
5. 2" X 1-1/2" hex brass bushing (MIPT x FIPT). 2 each 1-1/2i1Ibrassllar
bronze nipples 6" length, threaded ends. 2 each 1-1/2"-90` bras , for
bronze elbows (FIPT x FIPT).
6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal.
7. 1-1/2" soft copper tubing type K or brass nipples (MIPT x MIPT), length
to fit.
8. 1-1/2" threaded brass 90° ell, for Ford 4-77 or equal.
9. 1-1/2" Customsetter with by-pass For' VEH 86-12B-11-66 (x
13-3/16"), McDonald Brass: 30B612WDFF665 or Mueller B-1427-1 1/2",
with flanged angle ball valve and padlock wings on inlet, and angle check
valve outlet, ball valve on bypass with padlock wings. Customsetter shall
have vertical inlet and outlet.
10. Rigid meter spreader t,q be supplied and installed in meter setter by.
contractor.
11. Water meter shall Pher+Isupplied and installed by City of Renton upon
payment ofl�.al( re�dtedli .bter meter fee and satisfactory pressure and
purity tests.
12. 17"x30" Plastic meter box equal to Mid -States Plastics, Inc. BCF Series
MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31"
equal to Mid -States Plastics, Inc. MSCBC-1730-R with 2" drilled hole for
touchread pit lid.
13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford
C-14-66 or equal. The property owner is responsible for any necessary
adaptation or extension of water service.
ZY
*► �� PUBLIC WORKS 1 !2" AND 2" WATER SERVICE LOCATED STD. PLAN - 320.2
DEPARTMENT IN PLANTING STRIP
NTp� MARCH 2O10
1 1/2" AND 2" WATER SERVICE
LOCATED IN PLANTING STRIP WA7
NOT TO SCALE C06
R-401201
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
Aomttk vR MERRILL GARDENS AT RENTON CENTER- ADDITION
C TY OF
RENTON 104 BURNETT AVE S, RENTON, WA 98057
1waoPlan ning/Building/Public Works Dept. CITY DETAILS - MISC
1 /8/20
PAGE
DRAWING NO:
C18
SHEET: 18 OF: 34