HomeMy WebLinkAboutR-401218N
T'
I
0
W
I-
0
Z
W
r)
rr
a
J
Fr
rr
W
5
T
O
Print Form Reset Form Save Form
DEPARTMENT OF COMMUNITY i000000 CITY OF
AND ECONOMIC DEVELOPMENT Renton %
TREE RETENTION WORKSHEET
Planning Division
1055 South Grady Way -Renton, WA 98057
Phone:425-430-7200 1 www.rentonwa.gov
1. Total number of trees over 6" diameter', or alder or cottonwood
trees at least 8" in diameter on project site 0 trees
2. Deductions: Certain trees are excluded from the retention calculation:
Trees that are dangerous 0 trees
Trees in proposed public streets 0 trees
Trees in proposed private access easements/tracts 0 trees
Trees in critical areas3 and buffers 0 trees
Total number of excluded trees: 0 trees
3. Subtract line 2 from line 1: 0 trees
4. Next, to determine the number of trees that must be retained4, multiply line 3 by:
0.3 in zones RC, R-1, R-4, R-6 or R-8
0.2 in all other residential zones
0.1 in all commercial and industrial zones 0
S. List the number of 6" in diameter, or alder or cottonwood trees
over 8" in diameter that you are proposing5 to retain 4: 20
6. Subtract line 5 from line 4 for trees to be replaced:
(if line 6 is zero or less, stop here. No replacement trees are required) (20)
7. Multiply line 6 by 12" for number of required replacement inches: (240)
8. Proposed size of trees to meet additional planting requirement:
(Minimum 2" caliper trees required for replacement, otherwise enter 0)
9. Divide line 7 by line 8 for number of replacement trees6:
(If remainder is .5 or greater, round up to the next whole number) 0
trees
trees
trees
inches
inches pe
trees
1 Measured at 4.5' above grade.
Z A tree certified, in a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed
landscape architect, or certified arborist, and approved by the City.
3 Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050.
4 Count only those trees to be retained outside of critical areas and buffers.
5 The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-130H7a.
6 When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2") caliper or an evergre(
six feet (6) tall, shall be planted. See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees.
1
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\Tree Retention Worksheet.docx
EXISTING PYRUS CALLERYANA STREET
TREE ALONG WILLIAMS AVE S TO BE
REMOVED (OFF PROPERTY SITE).
EXISTING TREE GRATE TO BE SALVAGED
AND RETURNED TO THE CITY.
BURNETT AVE S
PRUNUS CERASIFERA STREET TREES
ALONG BURNETT AVE S AND PLANTING
STRIP TO BE RETAINED
(OFF PROPERTY SITE)
0 0 0 0 0 0 0 0 0 0 0 G* 0 0 0
----------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ---------�
' 0
CERCIDIPHYLLUM JAPONICUM STREET
TREES ALONG S TOBIN ST AND
PLANTING STRIP TO BE RETAINED
(OFF PROPERTY SITE) '
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --
NON -SIGNIFICANT SMALL PRUNUS OR
PYRUS 5P. TREE5, BOXWOOD AND
BARBERRY SHRUBS TO BE REMOVED
TREE RETENTION /LAND CLEARING PLAN
1 "=30'
FAzio
BASE MAP/TOPOGRAPHY PROVIDED BY
OTHERS. DCG CANNOT BE HELD LIABLE
ASSOCIATES INC
LANDSCAPE ARCHITECTS
102 NW Canal Street
Seattle, WA 98107
T:206 774 9490
�v
STATE OF
REGHSTERCN
S P CHITECT
FOR ACCURACY. CONTRACTOR SHALL
FIELD VERIFY GRADES, UTILITIES AND
ALL OTHER EX FEATURES &
CONDITIONS. IF CONDITIONS ARE NOT
AS SHOWN &/OR PLANS CANNOT BE
1
www.fazioassociates.com
ROBERT J. F D
CERT)FICATE N 966
CONSTRUCTED AS SHOWN, CONTACT
DCG PRIOR TO CONSTRUCTION.
NO.
CONSTRUCTION RECORD DRAWINGS
REVISION
WILLIAMS AVE S
SURVEYED: SCALE:
DESIGNED: AS NOTED
RJF, VW
DRAWN:
VW ONE INCH
VW 0 1/ 0 9/ 2 0 CHECKED: AT FULL SCALE
RJF IF NOT ONE INCH
BY DATE APPR APPROVED: RJF SCALE ACCORDINGLY
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
VERTICAL: NAVD 1988 •
HORIZONTAL: NAD 1983/1991 C T Y OF
R
RENTON
DATUM •
7
Planning/Building/Public Works Dept.
NORTH
0 30' 60'
R-401201
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
MERRILL GARDENS AT RENTON CENTER- ADDITION
104 BURNETT AVE S, RENTON, WA 98057
TREE RETENTION /
LAND CLEARING PLAN
N
O
O
I
T
Q
J
Cn
Z
W
0
aR
V
DATE:
01 /09/2020
J
PAGE:
DRAWING NO:
L0.00
Er
W