T
Gil �— G" WIDE TRENCH DUG
WITH TRENCHING MACHINE
FINISH GRADE
-III—III—III—I I �//�/, III —III-'
/AA/AAA — COMPACTED
-III j\\\/ — BACKFILL MATERIAL
z\�VA�V III DETECTION TAPE (GREEN)
G" ABOVE PIPE
CIO II
COMPACTED
BACKFILL MATERIAL
PVC ELEC. CONDUIT
(GRAY) (SIZE AS
SPECIFIED ON PLANS)
POWER SUPPLY TRENCH
NOT TO SCALE
21ptrench_REV
PARAPET OR BUILDING WALL
(SIZE AND PROFILE VARIES)
FILL GAP WITH STONE BALLAST
OR BLACK COBBLE STONE
IRRIGATION LATERAL AND POP-UP
PER PLAN/SPECIFICATIONS
GREEN ROOF TRAY
EDGING
SLIP SHEET OR APROVED EQUAL;
TO BE EXTENDED TO TOP OF BALLAST FILL
WATERPROOFING
PER ARCHITECTURAL
NOTE:
IRRIGATION TRENCH WIDTH SHALL ACCOMMODATE WIDEST
IRRIGATION FITTINGS; MAXIMUM WIDTH TO BE G"-WIDE.
SAWCUT EXIST
PAVEMENT IF
NECESSARY
SLEEVE TRENCH
NOT TO SCALE
r
EXISTING OR NEW ASPHALT, CONCRETE
OR MASONRY PAVED SURFACE
TACK SEAL JOINT
COMPACTED
BACKFILL MATERIAL
DETECTION TAPE (BLUE)
G" ABOVE PIPE
COMPACTED
BACKFILL MATERIAL
PVC SLEEVE WITH MAIN
OR LATERAL LINES OR
CONTROLLER WIRES
NOTES:
I . SLEEVE SIZE AS SHOWN ON
PLANS OR: I.D. OF SLEEVE TO
BE I " GREATER THAN O.D. OF PIPE.
2. SLEEVES REQUIRED UNDER ALL
PAVED AREAS.
3. ENDS OF SLEEVES EXTEND A MIN.
OF 1 '-0" BEYOND CONCRETE EDGE.
FILL GAP WITH STONE BALLAST
IRRIGATION LATERAL AND POP-UP
PER PLAN/SPECIFICATIONS
GREEN ROOF TRAY
EDGING; AROUND GREEN ROOF
PERIMETER IRRIGATION
SLIP SHEET OR APROVED EQUAL
WATERPROOFING
PER ARCHITECTURAL
NOTE:
IRRIGATION TRENCH WIDTH SHALL ACCOMMODATE WIDEST
IRRIGATION FITTINGS; MAXIMUM WIDTH TO BE G''-WIDE.
I I G G \/ G I--! A E G rl "/l G T/l I-1 I /`
CLOSE-UP VIEW OF PORTAL
SUBTERRANEAN IRRIGATION (ROOF MODULE)
21strench_REV � `J ) NOT TO SCALE
NOTE:
THIS DETAIL REPRESENTS AN APPROXIMATE
CONDITION FOR MOUNTING CONTROLLER
ON INTERIOR WALL. VERIFY EXACT LOCATION
FOR CONTROLLER WITH ELECTRICAL AND
ADJUST INSTALLATION ACCORDINGLY.
Ln
2'-0"
tray_irril
00
co
O
INDOOR WALL MOUNT ELECTRIC c:)
CD
CONTROLLER; SEE IRRIGATION
PLAN AND ELECTRICAL FOR T
LOCATIONS
PROVIDE ELECTRICAL CONDUIT
PER CODE AND MANU. KEQS.
PROVIDE CLEAN ACCESS HOLES
FOR REQ. CONDUIT
INISH GRADE
LOW VOLTAGE WIRING
PER CONTROLLER REQS.
SUBTERRANEAN IRRIGATION (@ PARAPET/WALLS) 5 Y
UBTERRANEAN IRRIGATION (@ EDGE)C6INDOOR CONTROLLER - INDOOR INSTALLATION
NOT TO SCALE tray_irri2COT TO SCALE tray_irri3 NOT TO SCALE AUTOCON_REV
BASE MAP/TOPOGRAPHY PROVIDED BY
FAzio
�C%�d13 OTHERS. DCG CANNOT BE HELD LIABLE
�� FOR ACCURACY. CONTRACTOR SHALL SURVEYED: SCALE:
1988
ASSOCIATES iNC FIELD VERIFY GRADES, UTILITIES AND HORZO TAL NAD D1983/1991
LANDSCAPE ARCHITECTS DESIGNED: AS NOTED
102 NW Canal Street STATE OF ALL OTHER EX FEATURES & RJF, VW
WAGION CONDITIONS. IF CONDITIONS ARE NOT DRAWN:
Seattle, WA 98107 5 E PSTERSTERCHITECT VW
AS SHOWN WOR PLANS CANNOT BE ONE INCH DATUM
T:206-774-9490 1 CONSTRUCTION RECORD DRAWINGS VW 01/09/20 CHECKED: AT FULL SCALE
www.fazioassociates.com ROBERT J. F G CONSTRUCTED AS SHOWN, CONTACT RJF IF NOT ONE INCH
CERTjFICATE N . 966 NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
DCG PRIOR TO CONSTRUCTION. RJF
R-401201
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CALL 811 (2) BUSINESS DAYS
BEFORE YOU DIG
(UNDERGROUND UTILITY
LOCATIONS ARE APPROXIMATE)
CVR TY OF MERRILL GARDENS AT RENTON CENTER- ADDITION
RENTON 104 BURNETT AVE S, RENTON, WA 98057
VA31117
Planning/Building/Public Works Dept. IRRIGATION DETAILS
Cn
Z
W
0
aR
V
DATE:
01 /09/2020
J
PAGE:
DRAWING NO:
Im
cr
L2.05
w
SHEET: nn OF: 34