Loading...
HomeMy WebLinkAboutT-401202":t MERRILL GARDENS STREET LIGHT IMPROVEMENTS Cn z w 0 rr Q 0 J J FF w 75 CV T O PROVIDE NEW STREET LUMINARIES AS REQUIRED BY THE CITY OF RENTON LAND USE ADVISORY NOTES DATED DECEMBER 29,2017. THE NEW LUMINARIES WILL BE INSTALLED ON THE EAST FRONTAGE OF THE NEW MERRILL GARDENS BUILDING ALONG WILLIAMS AVE S. THE LUMINARIES SELECTION AND PLACEMENTS SHALL MEET THE CITY OF RENTON ZONE STANDARDS FOR DOWNTOWN STREETSCAPE INCLUDING MINIMUM LIGHT LEVELS AND UNIFORMITY RATIO REQUIREMENTS. GENERAL NOTES 1, ALL WORK SHALL BE COMPLETED IN THE ACCORDANCE WITH THE CITY GUIDELINES AND STANDARDS, STANDARD SPECIFICATIONS, SPECIAL PROVISIONS AND THESE PLANS. 2. THE LOCATION OF ALL LUMINAIRES, JUNCTION BOXES AND CONDUIT SHOWN ON THIS PLAN ARE FOR GRAPHIC PRESENTATION ONLY AND FINAL LOCATIONS SHALL BE DETERMINED BY THE ENGINEER IN THE FIELD. ALL NEW CONDUIT SHALL BE PLACED WITHIN CITY OF RENTON RIGHT—OF—WAY. ALL NEW POLE FOUNDATION LOCATIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO EXCAVATION. AFTER EXCAVATION, VERIFY WITH ENGINEER THAT FIELD CONDITIONS ALLOW FOR ASSIGNED SPECIAL FOUNDATION. 3. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 4. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE LOCKING AND SKID RESISTANT LIDS. 5. EXISTING OR HIGHER ILLUMINATIONS LEVELS SHALL BE MAINTAINED BY USING EXISTING OR TEMPORARY ILLUMINATION UNTIL THE NEW SYSTEM IS OPERATIONAL. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING A CLEARANCE ZONE OF 15' AROUND EXISTING AERIAL POWER LINES DURING CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY. 6. JUNCTION BOXES FOR LUMINAIRES SHALL BE LOCATED PER POLE/JUNCTION BOX LAYOUT DETAILS OUTLINED ON SHEET E3.0 AND E3.1. 7. MAINTAIN A MINIMUM OF 4' CLEARANCE BETWEEN PROPOSED CONDUITS AND TREE CENTERLINES. FOR TRENCHING DETAILS. 8. CONTRACTOR SHALL CONTACT CITY OF RENTON MANAGER ERIC CUTSHALL (425) 430-7423 PRIOR TO DISCONNECTION OF POWER TO EXISTING LUMINARIES. CONTRACTOR SHALL COORDINATE WITH CITY PUBLIC WORKS TO PROVIDE POWER TO NEW LUMINARIES. 9• CONTRACTOR SHALL INCLUDE POLE ID NUMBER AND GPS COORDINATES ON AS—BULT DRAWINGS. 10. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR AHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON DAMAGE. INSTRUCTION TO BIDDERS 1. IT IS MANDATORY FOR THE CONTRACTOR TO VISIT THE SITE AND REVIEW THE EXISTING SYSTEM AND CONDITIONS IN ORDER TO BID THIS PROJECT. 2. DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACTOR SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. 3. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTOR'S COST. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. REVISIONS: DRAWING INDEX: E1.0 STREET LIGHTING GENERAL NOTES & SHEET INDEX E2.0 STREET LIGHTING — POWER & PHOTOMETRICS E3.0 STREET LIGHTING DETAILS E3.1 STREET LIGHTING DETAILS E4.0 SPECIFICATIONS CONSTRUCTION RECORD DRAWING: THIS SHEET CONTAINS AS —BUILT INFORMATION MINOR REVISIONS ARE SHOWN BY STRIKING THROUGH THE ORIGINAL TEXT ADN DENOTING THE AS —BUILT INFORMATION ADJACENT. OTHER REVISIONS ARE DENOTED BY REVISION CLOUDS. AS —BUILT INFORMATION WAS SURVEYED BY D.R. STRONG AND SUPPORTING PHOTOS AND DOCUMENTATION WAS PROVIDED BY SRM (CONTRACTOR) ABOSSEIN ENGINEERING IS RESPONSIBLE FOR NOTATING THE AS —BUILT INFORMATION ON THE DRAWINGS BUT IS NOT RESPONSIBLE FOR THE ORIGINAL AS —BUILT DATA P ROVIDED TO ABOSSEIN ENGINEERING. LUMINAIRE SCHEDULE SYMBOL CALLOUT MODEL DETAILS DESCRIPTION LAMP BALLAST MOUNTING INPUT VOLTS NOTE I POLE# AND CPS QUANTITY VOLTS INPUT DEFAULT TOTAL IES FILE ARM WATTS INFO WATTS ELEVATION LUMENS LENGTH ST1 Cyclone Lighting, umentra, Inc.160 CYCLONE LIGHTING BELL SHAPED (1) 80W 40 White LEDs ELECTRONIC POLE 90 120V 1 P 2W 15' POLE, TYPE PM4 NORTH POLE POINT 120 90 15' 9714 DOMIA—CY55P1 A—FGC-3-80W-4K 2 CY55P1 A—FGC-3-80W-4K — Frobisher Drive, Unit PENDANT LED FIXTUREWITH INDIVIDUAL WITH M222 ARM AN #23036. (K617CM) BK SWaterloo, LED LENS OPTICS AND CLEAR FLAT LENS BM11 BASE, BLACK POLE #51221380 OntarioNVLAP LAB N=178941.0j CODE 500084-0 E=1300836.1 04-29-2016 PHILIPS ADVANCE SOUTH POLE XITANIUM 120-277V #23098 LED DRIVER MODEL POLE #5121 LEDINTA070OC21 ODO N=178880.2LED E=13008334 70 4000 Outdoor, Area, Parking, Parks, Pathway, 3 Pedestrian, Roadway, Sidewalk, Site, Street, Walkway, Decorative Arm, Pendant, Pole, Wall Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 18465 NE 68TH ST REDMOIND, WA. 98052 PH: (425) 462-9441 FAX: (425) 462-9451 E-Mail: cservice@abossein.com www.abossein.com BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE WA FOR ACCURACY. CONTRACTOR SHALL z FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & 9�0 ��� CONDITIONS. IF CONDITIONS ARE NOT SsioNA AS SHOWN &/OR PLANS CANNOT BE CONSTRUCTED AS SHOWN, CONTACT DCG PRIOR TO CONSTRUCTION. R-401201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS N N O O Cfl AN u N 0 O O T a J 00 co Q0 O O O T TJ CALL 811 (2) BUSINESS DAYS BEFORE YOU DIG W LU (UNDERGROUND UTILITY 6� LOCATIONS ARE APPROXIMATE) < SURVEYED: SCALE: AS NOTED VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM RCITY 0 RENT 0 N • MERRILL GARDENS AT RENTON CENTER- ADDITION 104 BURNETT AVE S, RENTON, WA 98057 STREET LIGHTING GENERAL NOTES, DATE: 1 /21 /20 J DESIGNED: JW 3 CONSTRUCTION RECORD DRAWINGS CT 01/21/20 PAGE:FIELDB PAGE: 2 CIVIL C❑NSTRUCTI❑N PERMIT REVIEW #2 CT 09/18/18 DRAWN: JW ONE INCH DRAWING NO: 1 CIVIL C❑NSTRUCTI❑N PERMIT REVIEW #1 CT 07/26/18 CHECKED: AA AT FULL SCALE IF NOT ONE INCH Planning/Building/Public Works Dept. E1 .� W N REVISION BY DATE 1APPRIAA SCALE ACCORDINGLY SHEET INDEX 5 APPROVED: SHEET: OF: 0. G