Loading...
HomeMy WebLinkAboutMFP18001595DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP18001595 IVR Number: 18001595 Permit Informaon Permit Name:Seattle City Light Address/Locaon :03/30/2018Application Date:2144800485Parcel Number:13076 RENTON AVE S Permit Type:03/30/2018Issue Date:Franchise Permit Work Class:03/30/2019Expiration Date:Minor Utility Job Number:1803409Franchise Type:Electric Description:APPROVED WITH COMMENTS OR REDLINES Replace failing pole and replace transformer and anchor. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Patrick Williams Seattle City Light 700 5 Ave, #3200 (PO BOX 34023) seattle 98124 B: (206) 615-0665Applicant Attn: Accounts Payable SEATTLE CITY LIGHT - Billing PO BOX 34023 SEATTLE, WA 98124 B: (206) 450-1513ContactX CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Scott WarlickHolly Powers3/30/20183/30/2018MFP18001595Restoration Per City of Renton Standards MFP18001595Scott Warlick3/30/20188:00AM - 3:30PMMonday - Friday MFP18001595 FLAGGER (IF APPLICABLE) LEGEND CHANNELIZING DEVICES WORK VEHICLE F SIGN LOCATION LOCATION WORK AREA OR SEQUENTIAL ARROW PANEL HIGH LEVEL WARNING DEVICE S.C.L TRAFFIC CONTROL WO # 1803409 Date: 03/14/18 Location: 13076 RENTON AV Project Engineer: P. WILLIAMS TCP: njmr RENTON START DATE: PENDING ROAD CLASS DEFINITIONS CLASS I - Central Business, University District CLASS II - Arterial Streets, CLASS III - All partially or full controlled access arterial streets *Advanced warning signs if feasible ** Vertical barricades, cones, tubular guideposts Table X-l CLASS OF ROAD WARNING SIGN SPACING TAPER LENGTH (L) CHANNELIZING DEVICE SPACING IN FEET (maximum) WARNING SIGN IN FEET IN FEET VEHICLE BARRICADES & DRUMS OTHER** IN INCHES MIN. SIZE LANE WIDTH Taper (S) Tangent Taper (S) Tangent A B C I *75 90 Speed limit Speed limit X 2 15 30 30 X 30 II 150 150 75 150 200 Speed limit Speed limit X 2 20 50 30 X 30 III 300 300 150 400 500 Speed limit Speed limit X 2 30 80 48 X 48 10’ 12’RENT ON AV E S 11’ m i n P 194FOOTPRINT OF WORK ZONE: 10’ X 33’L50’A B UTILITYWORKAHEA D RIG HT LANE ENDSC N NTS 326NE PERMIT #_______S.C.L. TRAFFIC CONTROL PLAN 4 LN - 2 WY ARTERIAL W/ CENTER TURN LANE ~ RIGHT LANE CLOSURE SCL WILL WORK ON THE NORTHEAST SIDE OF RENTON AV S NORTH OF S 132ND ST, 84TH AVE S AT ONE LOCATION . SCL SHALL ASSIST PEDESTRIANS AND MAINTAIN LOCAL ACCESS. NOTE: NOTIFY METRO & SCHOOLS 10 DAYS IN ADVANCE (IF APPLICABLE). NOTE: REFER TO TABLE X-1 FOR TYPICAL DIMENSIONS OF A, B, C & L. TO: S 132ND ST BRIEF JOB DESCRIPTION: P 194: NE/Si RENTON AVE S, 2 NW 84TH AVE S ~REPLACE POLE ~REPLACE PISA & ANCHOR ~REPLACE TRANSFORMER ~TRANSFER EQUIPMENT ~INSTALL DOWNGUY S ID EW A L K TH I S S ID E O F S TR E E T ON L Y SPEEDLIMIT25 MFP18001595 Arrow board is required. Locate for appropriate site distance in the field. Roadwork ahead sign required.