HomeMy WebLinkAboutF_Lindbergh HS Parking Lot_Civil Construction Plans_170721.pdfSE 164TH STREET 128TH AVENUE SOUTHEASTSE 168TH STREET AHBL #102 NAIL AND WASHER N 168111.4814 E 1310100.7332 ELEV: 432.68 AHBL #103 NAIL AND WASHER N 138365.6984 E 1310258.3632 ELEV: 422.42 LINDBERGH SENIOR HIGH SCHOOL LINDBERGH POOL BASE BID PARKING LOT REPLACEMENT ALTERNATE BID ITEM 1 PAVEMENT OVERLAY ALTERNATE BID ITEM 2 PAVEMENT OVERLAY CONTRACTOR LAYDOWN AREA CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC N 0 100 200 1" = 100 FEET GRAPHIC SCALE 500 LEGAL DESCRIPTION VERTICAL DATUM SITE ADDRESS LINDBERGH POOL AT LINDBERGH HIGH SCHOOL 16740 128TH AVE SE, RENTON, WA 98058 UTILITIES WATER SOOS CREEK WATER DISTRICT PH: 1-253-630-9900 TELEPHONE CENTURY LINK PH: 1-800-244-1111 POWER PUGET SOUND ENERGY PH: 1-888-321-7779 GAS PUGET SOUND ENERGY PH: 1-888-321-7779 ONE CALL 8-1-1 SITE INFORMATION PARCEL#282305-9004 PARCEL AREA:22.89 AC PROJECT AREA:1.06 AC (BASE BID) 0.28 AC (ALTERNATE BID ITEM 1) 0.10 AC (ALTERNATE BID ITEM 2) TEMPORARY BENCHMARKS AHBL #102 NAIL AND WASHER N:168111.4814 E:1310100.7332 ELEV:432.68 AHBL #103 NAIL AND WASHER N:168365.6984 E:1310258.3632 ELEV:422.42 INSPECTION NOTIFICATION CITY OF RENTON DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT, DEVELOPMENT SERVICES 1055 SOUTH GRADY WAY RENTON, WA. 98057 PH: (425) 430-7200 OWNER RENTON SCHOOL DISTRICT 7812 S 124TH ST SEATTLE, WA 98178 PH: (425) 204-4470 CONTACT: STEWART SHUSTERMAN CIVIL ENGINEER AHBL, INC. 2215 NORTH 30TH STREET SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: BILL FIERST, P.E. SURVEYOR AHBL, INC. 2215 NORTH 30TH STREET SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: DAVID FOLLANSBEE, P.L.S. LANDSCAPE ARCHITECT BASIS OF BEARING IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. FILL SPECIFICATION TRENCH NOTE AN AUTOCAD DRAWING FILE IS AVAILABLE TO ASSIST WITH SITE LAYOUT. PLEASE NOTE THAT ELECTRONIC FILES ARE PROVIDED FOR CONTRACTOR'S CONVENIENCE AND SHALL NOT REPLACE NOR BE USED TO SUBSTITUTE THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PROJECT LAYOUT ACCORDING TO CONTRACT DOCUMENTS AND COST FOR ELECTRONIC AUTOCAD FILES. PHONE: (253) 383-2422 FAX: (253) 383-2572 AUTOCAD FILE 1.THE CONTRACTOR IS REQUIRED TO NOTIFY THE DEVELOPMENT SERVICES DIVISION, LAND USE INSPECTION SECTION (425) 430-7200, THREE DAYS PRIOR TO THE BEGINNING OF CONSTRUCTION FOR A PRECONSTRUCTION CONFERENCE AND SPECIFICALLY REQUEST INSPECTION BEFORE BEGINNING: A. INSTALLING SILTATION AND EROSION CONTROL MEASURES B. CLEARING AND GRUBBING C. EARTHWORK D. INSTALLATION OF ANY UNDERGROUND UTILITY E. BEFORE PLACING SUBBASE, BASE OR PAVING SURFACES F. INSTALLATION OF ANY FORMS OR PLACING ANY CONCRETE THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. UTILITY NOTE VICINITY MAP APPROX. 370 CUBIC YARDS CUT APPROX. 80 CUBIC YARDS FILL NET: APPROX. 290 CUBIC YARD CUT NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR THE PERMITTING PROCESS AND ARE NOT TO BE USED BY THE CONTRACTOR FOR BIDDING PURPOSES. THE CONTRACTOR SHALL MAKE THEIR OWN EARTHWORK DETERMINATION. ONSITE SOILS SHALL BE RE-USED TO THE MAXIMUM EXTENT FEASIBLE. CONTRACTOR SHALL OBTAIN IMPORT MATERIALS AND DISPOSE OF EXPORT MATERIALS AT APPROVED LOCATIONS TO BE DETERMINED PRIOR TO THE START OF CONSTRUCTION ACTIVITIES. EARTHWORK INFORMATION PRECONSTRUCTION NOTES NAVD 88 CITY OF RENTON VERTICAL BENCHMARK 1863 COPPER PIN IN CONC AT SE 168TH ST AND 116TH AVE SE ELEV: 459.077 WASHINGTON STATE PLANE COORDINATE SYSTEM, NORTH ZONE CITY OF RENTON HORIZONTAL CONTROL HOLDING CITY MONUMENT NUMBERS 1640 AND 1863. POINT NO. 1640 N=170648.9761 E=1305835.7466 BRASS DISK W/ PUNCH AT CL OF 116TH AVE SE. POINT NO. 1863 N=167989.6212 E=1305752.8500 COPPER PIN IN CONC AT SE 186TH ST AND 116TH AVE SE. AHBL, INC. 2215 NORTH 30TH STREET SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: KRISTIN GLANDON, PLA SE 1/4 OF NE 1/4 LESS E 500 FT OF N 1121 FT LESS E 330 FT OF S 216.47 FT M/L LESS S 250 FT OF E 523 FT OF W 553 FT LESS CO RD PROJECT AREA N COVER SHEET C1.0 CIVIL/LANDSCAPE SHEET INDEX SHEET NUMBER SHEET TITLE C1.0 COVER SHEET C2.0 TESC & DEMOLITION PLAN C2.1 TESC NOTES & LEGEND C2.2 TESC NOTES & DETAILS C3.0 GRADING & DRAINAGE PLAN C3.1 ENLARGED GRADING PLAN C3.2 STORM DRAINAGE PROFILES C4.0 PAVING & HORIZONTAL CONTROL PLAN C5.1 PAVING NOTES & DETAILS 1 C5.2 PAVING NOTES & DETAILS 2 C5.3 DRAINAGE NOTES & DETAILS 1 C5.4 DRAINAGE NOTES & DETAILS 2 C5.5 DRAINAGE NOTES & DETAILS 3 C5.6 DRAINAGE NOTES & DETAILS 4 L1.0 PLANTING PLAN L2.0 IRRIGATION PLAN L2.1 IRRIGATION DETAILS SEWER SOOS CREEK WATER DISTRICT PH: 1-253-630-9900 ELECTRICAL ENGINEER BCE ENGINEERS, INC. 6012 12TH STREET EAST SUITE 200 FIFE, WA 98424 PH. (253) 922-0446 FAX (253) 922-0896 CONTACT: MICHAEL L COZART, PE R-395901 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 1 1 1 1 1 2 2 2 2 2 2 2 2 3 4 4 4 9 5 5 5 66 6 7 7 7 7 8 8 9 9 9 10 10 14 11 11 11 11 12 12 12 13 13 13 13 13 13 13 13 13 1515 12'x6'6'x6' 15 15 5'x5' 12'x6' 10 10 16 16 9 17 17 17 17 18 FL 425.1 FL 424.3 S=1% FL 431.9 FL 431.2 S=1% 14 14 2 2 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC N GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 TESC & DEMOLITION PLAN C2.0 KEY NOTES SILT FENCE PER COR STD. PLAN 214.00 CATCH BASIN FILTER PER COR STD. PLAN 216.30 TEMPORARY CONSTRUCTION ENTRANCE PER COR STD. PLAN 215.10 PROTECT EXISTING STORM STRUCTURE AND ASSOCIATED APPURTENANCES, TYP. PROTECT EXISTING STORM DRAIN LINE, TYP. PROTECT EXISTING POWER AND COMMUNICATION STRUCTURE AND ASSOCIATED APPURTENANCES. SEE ELECTRICAL PLANS. PROTECT EXISTING POWER AND COMMUNICATION LINE. SEE ELECTRICAL PLANS. DEMOLISH EXISTING TREE DEMOLISH STORM DRAINAGE STRUCTURE. DEMOLISH STORM DRAIN LINE. DEMOLISH EXISTING POWER AND COMMUNICATION STRUCTURE AND ASSOCIATED APPURTENANCES. SEE ELECTRICAL PLANS. DEMOLISH EXISTING POWER AND COMMUNICATION LINE. SEE ELECTRICAL PLANS. DEMOLISH EXISTING SIGN. CUT AND CAP EXISTING STORM DRAIN LINE AT CATCH BASIN AND ABANDON IN PLACE. DEMOLISH AREA OF FAILED PAVEMENT AT APPROXIMATE SIZE AND LOCATION SHOWN. REMOVE PAVEMENT AND CURBING TO ACCOMMODATE UTILITY INSTALLATION. DEMOLISH EXISTING PAVEMENT AND CURB PROTECT EXISTING FENCE AND GATE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 3 C2.2 2 C2.2 1 C2.2 R-395902 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC TESC NOTES & LEGEND C2.1 1.DEMOLITION: IT IS THE INTENT OF THE WORK UNDER THIS CONTRACT TO INCLUDE THE DEMOLITION OF ALL EXISTING SITE IMPROVEMENTS AS INDICATED BY THIS DRAWING OR AS REQUIRED FOR NEW CONSTRUCTION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY REVIEW THE SITE CONDITIONS AND TO CORRELATE THESE OBSERVATIONS WITH THE PROJECT WORK AND INCLUDE ALL NECESSARY DEMOLITION, WHETHER SHOWN OR NOT, AND INCLUDE ALL SUCH COSTS IN THE BASE BID. 2.CLEARING: IT IS THE INTENT OF THE WORK UNDER THIS CONTRACT TO CONDUCT ALL CLEARING NECESSARY TO BE ABLE TO COMPLETE ALL THE WORK OF THIS PROJECT. CONTRACTOR SHALL PERFORM ADDITIONAL CLEARING TO CONSTRUCT ONSITE AND OFFSITE IMPROVEMENTS IF NECESSARY. 3.GENERAL CONTRACTOR SHALL PROVIDE AN ESC SUPERVISOR WHO IS A CERTIFIED EROSION AND SEDIMENT CONTROL LEAD. 4.CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS OF THE NPDES UNDER THE DOE'S GENERAL PERMIT FOR STORMWATER DISCHARGE FROM CONSTRUCTION ACTIVITIES AND THE SWPPP. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL REQUIRED RECORDS. 5.CONTRACTOR SHALL LEGALLY DISPOSE OFF THE OWNER'S PROPERTY, ALL DEMOLISHED AND REMOVED MATERIALS, UNLESS INDICATED OTHERWISE. 6.BACKFILL AND COMPACT ALL VOIDS AND DEPRESSIONS OCCURRING AS A RESULT OF DEMOLITION ACTIVITIES. SEE SPECIFICATIONS FOR ALLOWABLE BACKFILL MATERIALS. 7.REMOVE EXISTING SOD AND TOPSOIL AS NECESSARY TO PROVIDE IMPROVEMENTS. CONTRACTOR SHALL DISPOSE OF EXCESS SOD AND TOPSOIL OFFSITE. 8.CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF TESC FACILITIES. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF ADDITIONAL FACILITIES INCLUDING BUT NOT LIMITED TO FILTER FENCE, CATCH BASIN PROTECTION, SWALES, MULCHING AND SEEDING. 9.RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION CONTROL IS ALWAYS IN ACCORDANCE WITH THE MINIMUM CITY OF RENTON TESC REQUIREMENTS. 10.SEDIMENTS TRACKED ONTO PAVED SURFACES SHALL BE REMOVED BY SWEEPING. SEDIMENTS SHALL NOT BE WASHED DOWNSTREAM. SPRAY EXPOSED SOILS WITH WATER TO PREVENT DUST. RUNOFF SHALL NOT BE CREATED BY SPRAYING. EROSION CONTROL MEASURES SHALL BE PROVIDED THROUGHOUT CONSTRUCTION. WHEEL WASHES SHALL BE PROVIDED IF THE NOTED EROSION CONTROL MEASURES ARE NOT ADEQUATE TO PREVENT SEDIMENTS FROM ENTERING THE ROW 11.CONTRACTOR SHALL EXCAVATE AND FILL AS NECESSARY TO ACHIEVE SUBGRADES IN LAWN AND PLANTER BEDS REQUIRED BY THE LANDSCAPE PLANS. 12.PROTECT EXISTING UTILITIES WITHIN THE WORK LIMITS NOT SPECIFICALLY INDICATED FOR DEMOLITION. ADJUST EXISTING UTILITIES TO FINISHED GRADE. 13.CONTRACTOR SHALL INCLUDE IN BID REMOVAL OF ALL TESC MEASURES AT COMPLETION OF PROJECT. 14.SEE LANDSCAPE PLANS FOR FINAL VEGETATED SURFACING. 15.CONTRACTOR IS REQUIRED TO USE EXISTING TRUCK HAUL ROUTES AS NOTED PER CITY OF RENTON ORDINANCE 5339. ORDINANCE 5339 SPECIFIES THAT TRUCKS TAKE THE MOST DIRECT ARTERIAL ROUTE TO OR FROM ONE OF THE DESIGNATED TRUCK ROUTES. PARK AVENUE N. ADJACENT TO THE SITE IS THE NEAREST TRUCK ROUTE 16.THE SITE TOPOGRAPHIC SURVEY WAS COMPLETED BY THE OWNER'S CONSULTANT. PRIOR TO CONSTRUCTION AND MOVING MATERIAL, THE CONTRACTOR SHALL REVIEW THE SURVEY AND PROVIDE THE OWNER A SIGNED LETTER INDICATING THE CONTRACTOR AGREES WITH THE CONDITIONS NOTED BY THE SURVEY. IF THE CONTRACTOR DOES NOT AGREE WITH THE CONDITIONS OF THE SURVEY, THE CONTRACTOR SHALL COMPLETE AN INDEPENDENT 3RD PARTY SURVEY AND PROVIDE IT TO THE OWNER FOR REVIEW PRIOR TO CONSTRUCTION OR MOVING MATERIAL. GENERAL NOTES: 1.ARRANGE AND ATTEND PRE-CONSTRUCTION MEETING WITH CITY OF RENTON, OWNER, CONTRACTOR, ESC LEAD, AND ENGINEER. STAKE CLEARING LIMITS PRIOR TO THIS MEETING. 2.POST NOTICE OF CONSTRUCTION ACTIVITY SIGN WITH NAME AND PHONE NUMBER OF ESC LEAD. 3.FENCE CLEARING LIMITS AND TREE PROTECTION AREAS. 4.INSTALL CATCH BASIN SEDIMENT PROTECTION. 5.INSTALL PERIMETER PROTECTION (SILT FENCE, OR OTHER MEASURES) WHERE SPECIFIED ON THE ESC PLAN AND/OR REQUIRED BY THE CITY INSPECTOR. 6.GRADE AND STABILIZE CONSTRUCTION ENTRANCE. 7.DEMOLISH EXISTING PAVEMENT AREAS AS INDICATED ON PLAN. 8.CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR SWALES, CHECK DAMS, TEMPORARY SEDIMENT POND, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 9.PROVIDE PLASTIC COVERING ON ALL EXPOSED SLOPES 5H:1V OR GREATER. ALL FILLS MUST BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER. 10.MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON STANDARDS, NPDES PERMIT AND EROSION AND SEDIMENT CONTROL REPORT. 11.RELOCATE SURFACE WATER CONTROLS AND EROSION CONTROL MEASURES OR INSTALL NEW MEASURES, SO THAT, AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF RENTON EROSION AND SEDIMENT CONTROL REQUIREMENTS. 12.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCT 1 TO APR 30) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1 TO SEPT 30) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC MEASURES. 13.ROUGH GRADE SITE. 14.CONSTRUCT PERMANENT STORMWATER FACILITIES. 15.CONSTRUCT ALL OTHER SITE IMPROVEMENTS. 16.SEED OR SOD ANY AREA TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 17.UPON SUBSTANTIAL COMPLETION, ALL DISTURBED AREAS MUST BE STABILIZED. EROSION AND SEDIMENT CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL APPROVAL IS OBTAINED FROM THE CITY OR RENTON. CONSTRUCTION SEQUENCE: 1.MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND SHALL BE APPLIED AT THE RATE OF 2 TONS/ACRE. 2.MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED SLOPES GREATER THAN 2:1. 3.MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR IN AREAS WHICH CANNOT BE SEEDED BECAUSE OF THE SEASON. 4.ALL AREAS NEEDING MULCH SHALL BE COVERED BY NOVEMBER 1. MULCHING NOTES: HYDROSEEDING NOTES: 1.HYDROSEEDING SHALL BE APPLIED TO ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES UNLESS OTHERWISE NOTED. 2.HYDROSEEDING TO BE AS SPECIFIED IN LANDSCAPE SPECIFICATIONS. 3.APPLICATION TO BE 100 LBS/ACRE. 4.500 LBS/ACRE 10-20-20 FERTILIZER, 2000 LBS/ACRE MULCH AND 40 LBS/ACRE SOIL STABILIZER TO BE APPLIED WITH SEED MIXTURE. 5.SEED BEDS PLANTED BETWEEN MAY 1 AND OCTOBER 31 WILL REQUIRE IRRIGATION AND OTHER MAINTENANCE AS NECESSARY TO FOSTER AND PROTECT THE ROOT STRUCTURE. CONTRACTOR SHALL ENSURE PROPER ROOT GROWTH REGARDLESS OF PLANTING SCHEDULE. 6.FOR SEED BEDS PLANTED BETWEEN OCTOBER 31 AND APRIL 30, ARMORING OF THE SEED WILL BE NECESSARY. (EG, GEOTEXTILES, JUTE MAT, CLEAR PLASTIC COVERING.) 7.BEFORE SEEDING, INSTALL NEEDED SURFACE RUNOFF CONTROL MEASURES SUCH AS GRADIENT TERRACES, INTERCEPTOR DIKES, SWALES, LEVEL SPREADERS AND SEDIMENT BASINS. 8.THE SEEDBED SHALL BE FIRM WITH A FAIRLY FINE SURFACE, FOLLOWING SURFACE ROUGHENING. PERFORM ALL OPERATIONS ACROSS OR AT RIGHT ANGLES TO THE SLOPE. 9.FERTILIZERS ARE TO BE USED ACCORDING TO SUPPLIERS RECOMMENDATIONS. AMOUNTS USED SHOULD BE MINIMIZED, ESPECIALLY ADJACENT TO WATER BODIES AND WETLANDS. 10.SEE SPECIFICATIONS FOR HYDROSEED MIXTURES. INSPECTION SCHEDULE: 1.ALL ESC MEASURES SHALL BE MAINTAINED AND REVIEWED ON A REGULAR BASIS. 2.THE ESC SUPERVISOR SHALL REVIEW THE SITE AT LEAST WEEKLY AND WITHIN 24 HOURS OF SIGNIFICANT STORMS. A SIGNIFICANT STORM IS ONE WITH MORE THAN 0.5 INCHES OF RAIN IN 24 HOURS OR LESS. 3.THE CITY MAY REQUIRE THAT A WRITTEN RECORD OF THESE REVIEWS BE KEPT ON SITE WITH COPIES SUBMITTED TO THE CITY WITHIN 48 HOURS. EROSION CONTROL NOTES: 1.THESE NOTES SHALL APPEAR FOR ALL PROJECTS - SITE IMPROVEMENTS, SURFACE WATER UTILITY, WASTEWATER UTILITY, WATER UTILITY, AND TRANSPORTATION PLANS: 2.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON, PUBLIC WORKS DESIGN ENGINEER. 3.THE BOUNDARIES OF THE CLEARING LIMITS AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY FLAGGED BY SURVEY TAPE OR FENCING IN THE FIELD PRIOR TO CONSTRUCTION IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND OBSERVED DURING CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 4.STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. 5.ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON-SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITEE. 6.THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE PERMITEE SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 7.APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR RETENTION FACILITIES. 8.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH MARCH 30TH) OR SEVEN DAYS DURING THE DRY SEASON (APRIL 1ST THROUGH SEPTEMBER 30) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.). 9.WET SEASON SEASONAL EROSION AND SEDIMENT CONTROL REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES CLEARING BETWEEN OCTOBER 1 AND MARCH 30 INCLUSIVE, UNLESS OTHERWISE APPROVED BY THE CITY THROUGH AN ADJUSTMENT PROCESS. 10.COVER MEASURES WILL BE APPLIED IN CONFORMANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL. 11.ANY AREA NEEDING ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS DURING NON WET SEASON. 12.THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. 13.AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT- LADEN WATER INTO THE DOWNSTREAM SYSTEM. 14.ANY PERMANENT RETENTION/DETENTION FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. 15.PRIOR TO THE BEGINNING OF THE WET SEASON (OCT. 1), ALL DISTURBED AREAS SHALL BE REVIEWED TO IDENTIFY WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. A SKETCH MAP OF THOSE AREAS TO BE SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY OF RENTON FOR REVIEW. 16.ALL TESC MEASURES MUST BE REMOVED AFTER CONSTRUCTION AND SITE IS STABILIZED. 17.DISTURBED AREAS UNWORKED FOR 7 CONSECUTIVE WORKING DAYS SHALL BE STABILIZED WITH COVER MEASURES EXCEPT DURING THE WET SEASON. DURING THE WET SEASON DISTURBED AREAS UNWORKED FOR TWO CONSECUTIVE WORKING DAYS SHALL BE STABILIZED WITH COVER MEASURES. 18.STOCKPILES AND STEEP CUT AND FILL SLOPES SHALL BE PROTECTED IF UNWORKED FOR MORE THAN 12 HOURS. 19.COVER MATERIALS SUFFICIENT TO COVER ALL DISTURBED AREAS SHALL BE STOCKPILED ON SITE. 20.ALL AREAS THAT ARE TO BE UNWORKED DURING THE WET SEASON SHALL BE SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON . 21.MULCH IS REQUIRED TO PROTECT ALL SEEDED AREAS. 22.FIFTY LINEAR FEET OF SILT FENCE (AND THE NECESSARY STAKES) PER ACRE OF DISTURBANCE SHALL BE STOCKPILED ON SITE. 23.CONSTRUCTION ROAD AND PARKING LOT STABILIZATION ARE REQUIRED FOR ALL SITES UNLESS THE SITE IS UNDERLAIN BY COARSE-GRAINED SOIL. 24.ANY RUNOFF GENERATED BY DEWATERING SHALL BE REQUIRED TO DISCHARGE TO THE SANITARY SEWER (WITH APPROPRIATE DISCHARGE AUTHORIZATION), PORTABLE SAND FILTER SYSTEMS, OR HOLDING TANKS. SOIL NOTES: A.THE SOIL MOISTURE HANDLING CAPACITY OF ALL NEW PERVIOUS SURFACING THAT, AT PROJECT COMPLETION, WILL NOT BE COVERED BY IMPERVIOUS SURFACING OR INCORPORATED INTO A DRAINAGE FACILITY MUST BE PROTECTED. THE DUFF LAYER AND NATIVE TOPSOIL SHALL BE RETAINED IN AN UNDISTURBED STATE TO THE MAXIMUM EXTENT FEASIBLE. B.ANY DUFF LAYER OR TOPSOIL REMOVED DURING GRADING SHALL BE STOCKPILED ONSITE IN A DESIGNATED, CONTROLLED AREA NOT ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS. THE MATERIAL SHALL BE REAPPLIED TO OTHER PORTIONS OF THE SITE WHERE FEASIBLE. C.THE SOIL IN ANY AREA THAT HAS BEEN COMPACTED OR THAT HAS HAD SOME OR ALL OF THE DUFF LAYER OR UNDERLYING TOPSOIL REMOVED SHALL BE AMENDED TO MITIGATE FOR LOSS OF MOISTURE HOLDING CAPACITY. THE AMENDMENT SHALL TAKE PLACE BETWEEN MAY 1 AND OCTOBER 1. REPLACED TOPSOIL SHALL BE A MINIMUM OF 8 INCHES THICK. REPLACED TOPSOIL SHALL HAVE AN ORGANIC MATTER CONTENT BETWEEN 8 AND 13 PERCENT DRY WEIGHT AND A PH SUITABLE FOR THE PROPOSED LANDSCAPE PLANTS. SEE LANDSCAPE PLANS EXISTING LEGEND: SURVEY SET NAIL AND WASHER MISCELLANEOUS BOLLARD SIGN AS NOTED FENCE SANITARY SEWER SANITARY SEWER MANHOLE SANITARY SEWER CLEANOUT SANITARY SEWER LINE STORM DRAINAGE STORM CATCH BASIN STORM MANHOLE ROOF DRAIN STORM LINE NATURAL GAS GAS VALVE GAS LINE POWER ELECTRICAL VAULT JUNCTION BOX LUMINAIRE ELECTRICAL LINE COMMUNICATION LINE TREES C=CEDAR CW=COTTONWOOD, M=MAPLE, U= UNKNOWN SURFACING CONCRETE ASPHALT CONTOUR MAJOR INTERVAL CONTOUR MINOR INTERVAL PROPERTY/RIGHT-OF-WAY LINE EXISTING FEATURE TO BE DEMOLISHED EXISTING FEATURE TO REMAIN SAWCUT LINE WORK LIMITS SILT FENCE (COR STD. PLAN 214.00) INTERCEPTOR SWALE (COR STD. PLAN 217.10) CHECK DAM (COR STD. PLAN 217.40) CATCH BASIN FILTER (COR STD. PLAN 216.30) STABILIZED CONSTRUCTION ENTRANCE (COR STD. PLAN 215.10) DEMOLISH EXISTING PAVEMENT TESC & DEMOLITION LEGEND: 3 C2.2 2 C2.2 BLACK LINES & HATCHES 4 C2.2 5 C2.2 1 C2.2 ANY LINETYPE GRAY LINES & HATCHES ANY LINETYPE R-395903 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC TESC NOTES & DETAILS C2.2 1 NOT TO SCALE CONSTRUCTION ENTRANCE (COR STD. PLAN 215.10) 2 NOT TO SCALE CATCH BASIN FILTER (COR STD. PLAN 216.30)3 NOT TO SCALE SILT FENCE (COR STD. PLAN 214.00) 4 NOT TO SCALE INTERCEPTOR SWALE (COR STD. PLAN 217.10) 5 NOT TO SCALE CHECK DAM (COR STD. PLAN 217.40) R-395904 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 EX STCB 1349 CB-2 FILTERRA 2 FILTERRA 3 CB-3 CB-4 CB-5 CB-6 CB-8 CB-1 CB-9 CB-10 CB-11 CB-12 CB-14 CB-15 FG: 433.78 (MATCH EX) FG: 433.18 (MATCH EX) 433.08 433.81 434.30 434.53 434.90 435.64 435.86 436.27 436.40 437.49 437.68 437.44 436.40 436.48 435.46 435.62 435.10 435.21 434.45 433.56 433.47 433.75 434.56 434.34 434.24 432.09 431.05 430.14 430.55 428.18 427.19 432.64 431.47 430.76 432.66 431.82 431.57 431.25 432.81 CAP PIPE FOR FUTURE CONNECTION IE: 416.50 12" (SE) 110 LF 12" CPEP @ 3.51% 8 6 L F 1 2 " C P E P @ 4 . 5 1 % 62 LF 12" CPEP @ 1.00% 14 LF 6" PVC @ 1.00% 435.79 FG: 423.43 (MATCH EX) FG: 426.84 (MATCH EX) FG: 425.87 (MATCH EX) FG: 435.65 (MATCH EX) FG: 436.97 (MATCH EX) FG: 436.53 (MATCH EX) 436.64 SEE SHEET C3.1 FOR DETAILED GRADING IN THIS AREA CB-16 35 LF 12" @ 1.29% 120 LF 6" PERF PVC @ 0.00% CO-2 120 LF 6" PERF PVC @ 3.40%CO-1154 LF 6" PERF PVC @ 3.96%CO-4 CO-5 CO-6 70 LF 6" PVC @ 1.00% CO-3 117 LF 6" PERF PVC @ 0.00% FG: 436.05 (MATCH EX) FG: 436.37 (MATCH EX) FG: 429.20 (MATCH EX) FG: 422.43 (MATCH EX) 427.66 427.36 429.05 26 LF 12" CMP @ 0.00% 8 LF 6" PVC @ 1.00% CB-7 FILTERRA 1 35 LF 12" CPEP @ 4.63% 17 LF 12" CPEP @ 11.97% 31 LF 12" CPEP @ 1.21% 8 LF 10" PVC @ 1.00% 6 LF 12" CPEP @ 2.00%4254304264274284294314324334254254304354354234234244244264264274284294314324334344344364 3 7 437 CB-13 FLOW DIRECTION FLOW DIRECTION STORM STRUCTURE TABLE STRUCTURE NAME CB-1 CB TYPE 1 N 168396.86 E 1310205.33 CB-2 54" TYPE 2 CB N 168218.26 E 1310191.14 CB-3 54" TYPE 2 CB N 168345.01 E 1310188.56 CB-4 54" TYPE 2 CB N 168340.86 E 1310195.40 CB-5 54" TYPE 2 CB N 168336.71 E 1310202.24 CB-6 54" TYPE 2 CB N 168332.55 E 1310209.08 CB-7 CB TYPE 1 N 168337.91 E 1310212.33 CB-8 54" TYPE 2 CB N 168328.40 E 1310215.91 CB-9 54" TYPE 2 CB N 168324.25 E 1310222.75 STRUCTURE DETAILS RIM = 424.40 IE = 421.40 (12" SE) IE = 421.40 (12" W) RIM = 427.36 IE = 416.50 (36" NE) IE = 423.61 (6" SE) RIM = 425.42 IE = 416.50 (36" SW) IE = 422.09 (12" W) RIM = 425.08 IE = 416.50 (36" SW) RIM = 424.78 IE = 416.50 (36" SW) RIM = 424.59 IE = 416.50 (36" SW) IE = 420.71 (12" NE) RIM = 424.96 IE = 420.92 (10" SE) IE = 420.84 (12" SW) RIM = 424.48 IE = 416.50 (36" SW) RIM = 424.45 IE = 416.50 (36" SW) STORM STRUCTURE TABLE STRUCTURE NAME CB-10 54" TYPE 2 CB N 168318.02 E 1310233.01 CB-11 54" TYPE 2 CB N 168313.87 E 1310239.84 CB-12 60" TYPE 2 CB CONTROL MH N 168309.71 E 1310246.68 CB-13 48" TYPE 2 CB N 168323.38 E 1310257.41 CB-14 60" TYPE 2 CB N 168347.41 E 1310276.28 CB-15 48" TYPE 2 CB N 168348.82 E 1310338.74 CB-16 48" TYPE 2 CB N 168353.32 E 1310373.45 CO-1 CO N 168116.49 E 1310124.64 CO-2 CO N 168219.06 E 1310186.94 STRUCTURE DETAILS RIM = 423.99 IE = 416.50 (36" SW) RIM = 423.64 IE = 416.50 (36" SW) RIM = 423.28 IE = 416.50 (36" SW) IE = 416.50 (12" NE) RIM = 422.50 IE = 414.42 (12" SW) IE = 414.42 (12" NE) IE = 414.92 (6" W) RIM = 421.30 IE = 418.58 (6" SE) IE = 414.05 (12" E) IE = 417.50 (12" NW) IE = 414.05 (12" SW) IE = 417.97 (6" N) IE = 414.30 (6" W) IE = 417.78 (12" W) RIM = 419.98 IE = 413.43 (12" W) IE = 417.81 (6" SE) IE = 413.43 (12" E) RIM = 416.98 IE = 412.98 (12" W) IE = 412.98 (12" E) RIM = 431.53 IE = 429.83 (6" NE) RIM = 427.47 IE = 415.00 (6" NE) IE = 425.75 (6" SW) STORM STRUCTURE TABLE STRUCTURE NAME CO-3 CO N 168321.62 E 1310249.23 CO-4 CO N 168118.37 E 1310064.95 CO-5 CO N 168250.32 E 1310145.09 CO-6 CO N 168350.65 E 1310206.03 EX STCB 1349 EXISTING TYPE 1 CB N 168377.13 E 1310096.70 FILTERRA 1 10'x6' FTIBC N 168331.16 E 1310223.44 FILTERRA 2 4'x4' FTIBC N 168210.98 E 1310203.11 FILTERRA 3 12'x4' FTIBC N 168336.90 E 1310153.10 STRUCTURE DETAILS RIM = 422.99 IE = 415.00 (6" SW) IE = 415.00 (6" E) RIM = 434.04 IE = 432.54 (6" NE) RIM = 427.93 IE = 426.43 (6" SW) IE = 415.00 (6" NE) RIM = 425.05 IE = 415.00 (6" SW) IE = 415.00 (6" E) RIM = 428.62 IE = 425.27 (12" W) IE = 425.27 (12" E) RIM = 424.42 IE = 421.00 (10" NW) RIM = 427.17 IE = 423.75 (6" NW) RIM = 427.11 IE = 423.69 (12" SE) 1 4 4 4 4 4 2 4 4 4 4 5 3 3 4 7 7 7 7 7 7 4 6 6 6 INLET INLET INLET TOP = 424.92 TOP = 427.67 TOP = 427.61 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC N GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 GRADING & DRAINAGE PLAN C3.0 LEGEND: STORM CATCH BASIN STORM MANHOLE STORM DRAINAGE CLEANOUT DETENTION TANK ACCESS RISER GRADE BREAK STORM LINE PERFORATED PIPE STORM LINE LARGE DIAMETER DETENTION PIPE CONTOUR LINE PROPERTY/RIGHT-OF-WAY LINE XXX KEYNOTES: TYPE 1 CATCH BASIN WITH HERRINGBONE GRATE TYPE 1 CATCH BASIN WITH SOLID COVER TYPE 2 CATCH BASIN WITH HERRINGBONE GRATE TYPE 2 CATCH BASIN WITH ROUND SOLID LID FLOW CONTROL MANHOLE FILTERRA VAULT STORM CLEANOUT 1 2 3 4 5 6 7 1 C5.3 2 C5.4 1 C5.3 1 C5.4 2 C5.3 2 C5.4 2 C5.3 3 C5.4 1 C5.6 4 C5.6 1 C3.2 1 C3.2 1 C3.2 1 C3.2 1 C3.2 2 C3.2 2 C3.2 3 C3.2 4 C3.2 1 C5.5 1.SEE SHEETS C3.1 AND C5.3 FOR GENERAL STORM DRAINAGE NOTES. NOTE: 5 C5.4 3 C3.2 R-395905 6 C5.4 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 4254264254234 2 3 424FG: 426.30 FG: 426.10 FG: 426.07 FG: 425.90 FG: 425.87 FG: 426.19 (MATCH EX) FG: 425.95 FG: 424.98 FG: 424.78 TC: 425.28 FG: 424.69 TC: 425.20 FG: 424.64 TC: 425.14 FG: 424.55 TC: 425.05 FG: 424.50 TC: 425.00 FG: 424.45 FG: 424.61 FG: 424.68 FG: 424.56 FG: 424.53 TC: 424.92 FG: 424.58 TC: 425.01 FG: 425.04 TC: 425.47 FG: 423.45 TC: 423.95 FG: 423.78 FG: 423.83 FG: 423.26 (MATCH EX) FG: 423.09 (MATCH EX) FG: 422.23 (MATCH EX) FG: 424.06 FG: 423.40 FG: 423.78 FG: 421.88 (MATCH EX) FG: 422.14 (MATCH EX) FG: 424.25 FG: 422.68 (MATCH EX) FG: 425.41 (MATCH EX) FG: 424.72 FG: 426.01 FG: 426.18 FG: 424.89 FG: 424.79 (MATCH EX) FG: 424.42 FG: 424.45 FG: 427.14 (MATCH EX) FG: 427.57 (MATCH EX) FG: 427.12 FG: 427.11 FG: 424.751. 0 0 % 4.45 %1.00%1.00%0. 9 9 % 1. 2 6 %1.00%1.24%1.17%FG: 425.96 FG: 424.84 FG: 424.70 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 ENLARGED GRADING PLAN C3.1 1.FOR BEDDING AND BACKFILL PIPE TRENCHES DETAIL SEE DETAIL 4 ON SHEET C5.5. 2.ALL STORM PIPE SHALL BE LINED CORRUGATED POLYETHYLENE PIPE OR AS ALLOWED BY THE CITY OF RENTON 2016 DRAINAGE MANUAL UNLESS OTHERWISE NOTED. 3.SPOT ELEVATIONS AND CONTOURING SHOWN REPRESENT FINISH GRADE ELEVATIONS. SUBGRADE ELEVATIONS WILL VARY DEPENDING UPON TYPE OF SURFACING REQUIRED. REFER TO SPECIFICATIONS FOR TOPSOIL AND MULCH DEPTHS. 4.MATCH EXISTING GRADES AT INTERFACE WITH EXISTING SURFACING. VERIFY EXISTING GRADES AT INTERFACE PRIOR TO ORDERING MATERIALS AND CONSTRUCTING. 5.CONTRACTOR SHALL VERIFY ALL EXISTING AND PROPOSED GRADES PRIOR TO CONSTRUCTION ACTIVITIES. CONTACT ENGINEER IF PROPOSED GRADES ARE BELIEVED TO BE IN ERROR. 6.SEE SHEET C5.3 FOR STANDARD SURFACE WATER PLAN NOTES AND CONSTRUCTION SEQUENCE. 7.FINISHED GRADES ARE INDICATED. CONTRACTOR SHALL EXCAVATE AND FILL TO ACHIEVE PROPER SUBGRADES. 8.ALL FILL MATERIALS SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 9.ADJUST EXISTING UTILITY LIDS FOR FINISHED GRADE. 10.CATCH BASIN TYPE 1 PER CITY OF RENTON STANDARD PLAN 200.00, SEE DETAIL 1 ON SHEET C5.3. 11.CATCH BASIN TYPE 2 PER CITY OF RENTON STANDARD PLAN 201.00, SEE DETAIL 2 ON SHEET C5.3. 12.CATCH BASIN INSTALLATION PER CITY OF RENTON STANDARD PLAN 202.00, SEE DETAIL 3 ON SHEET C5.3. 13.RECTANGULAR FRAME PER CITY OF RENTON STANDARD PLAN 204.00, SEE DETAIL 4 ON SHEET C5.3. 14.RECTANGULAR SOLID COVER PER CITY OF RENTON STANDARD PLAN 204.10, SEE DETAIL 1 ON SHEET C5.4. 15.ALL ONSITE TYPE 1 CATCH BASINS SHALL HAVE HERRINGBONE GRATES UNLESS OTHERWISE INDICATED. RECTANGULAR HERRINGBONE GRATE PER CITY OF RENTON STANDARD PLAN 204.40, SEE DETAIL 2 ON SHEET C5.4. 16.STORM ROUND FRAME AND COVER PER CITY OF RENTON STANDARD PLAN 204.50, SEE DETAIL 3 ON SHEET C5.4. 17.MISCELLANEOUS DETAILS FOR DRAINAGE STRUCTURES PER CITY OF RENTON STANDARD PLAN 204.60, SEE DETAIL 4 ON SHEET C5.4. 18.ALL DISTURBED SOILS IN PERVIOUS AREAS SHALL BE AMENDED IN ACCORDANCE WITH THE SOIL AMENDMENT STANDARDS FOUND IN SECTION C.2.13 OF THE 2017 CITY OF RENTON STORMWATER MANUAL. GENERAL NOTES: R-395906 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 405 410 415 420 425 430 405 410 415 420 425 430 0+00 0+50 426.091+00425.02424.071+50423.06422.082+00 2+50 3+00 STA: 1+10.41, 0.00 IE: 421.40 12" (SE) IE: 421.40 12" (W) CB TYPE 1 RIM: 424.40 CB-1 STA: 1+96.89, 0.00 IE: 418.58 6" (SE) IE: 414.05 12" (E) IE: 417.50 12" (NW) IE: 414.05 12" (SW) IE: 417.97 6" (N) IE: 414.30 6" (W) IE: 417.78 12" (W) 60" TYPE 2 CB RIM: 421.30 CB-14 STA: 2+59.37, 0.00 IE: 413.43 12" (W) IE: 417.81 6" (SE) IE: 413.43 12" (E) 48" TYPE 2 CB RIM: 419.98 CB-15 STA: 2+94.37, 0.00 IE: 412.98 12" (W) IE: 412.98 12" (E) 48" TYPE 2 CB RIM: 416.98 CB-16 110 LF 1 2 " C P E P S T M @ 3 . 5 1 % 86 LF 1 2 " C P E P S T M @ 4 . 5 1 % 62 LF 12" CPEP STM @ 1.00% 35 LF 12" CPEP STM @ 1.29% EXISTING GRADE OVER STORM LINE FINISHED GRADE OVER STORM LINE EXISTING GRADE OVER STORM LINE FINISHED GRADE OVER STORM LINE STA: -0+00, 0.00 IE: 425.27 12" (W) IE: 425.27 12" (E) EXISTING TYPE 1 CB RIM: 428.62 EX STCB 1349 (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) 405 410 415 420 425 430 405 410 415 420 425 430 0+00427.36426.590+50425.54424.531+00423.56422.471+50 EXISTING GRADE OVER STORM LINE FINISHED GRADE OVER STORM LINE EXISTING GRADE OVER STORM LINE FINISHED GRADE OVER STORM LINE STA: 0+00, 0.00 IE: 416.50 36" (NE) IE: 423.61 6" (SE) 54" TYPE 2 CB RIM: 427.36 CB-2 50 LF 60" CMP STM @ 0.00% ACCESS HATCH STA 0+53.50, 0.00 RIM: 425.43 IE: 416.00 60" (NE) IE: 416.00 60" (SW) IE: 416.50 12" (NW) 50 LF 60" CMP STM @ 0.00% STA: 1+07, 0.00 IE: 416.50 36" (SW) IE: 416.50 12" (NE) RIM: 423.28 CB-12 60" TYPE 2 CB CONTROL MH CB-14 STA: 1+24.38, 0.00 IE: 414.42 12" (SW) IE: 414.42 12" (NE) IE: 414.92 6" (W) 48" TYPE 2 CB RIM: 422.50 CB-13 17 LF 12" CPEP STM @ 11.97% 31 LF 12" CPEP STM @ 1.21% 410 415 420 425 430 435 410 415 420 425 430 435 0+00434.04433.090+50431.97431.031+00430.06429.081+50428.10427.132+00426.16425.412+50425.09424.893+00423.36422.10EXISTING GRADE OVER STORM LINE FINISHED GRADE OVER STORM LINE STA: 0+00, 0.00 IE: 432.54 6" (NE) CO RIM: 434.04 CO-4 STA: 1+54.38, 0.00 IE: 426.43 6" (SW) IE: 415.00 6" (NE) CO RIM: 427.93 CO-5 154 LF 6 " P E R F P V C S T M @ 3 . 9 6 % 117 LF 6" PERF PVC STM @ 0.00% STA: 2+71.76, 0.00 IE: 415.00 6" (SW) IE: 415.00 6" (E) CO RIM: 425.05 CO-6 CB-14 70 LF 6" PVC STM @ 1.00% EXISTING GRADE OVER STORM LINE FINISHED GRADE OVER STORM LINE DETENTION TANK 410 415 420 425 430 410 415 420 425 430 0+00427.51426.020+50424.90424.291+00423.13STA: 0+00, 0.00 IE: 423.69 12" (SE) RIM: 427.11 FILTERRA 3 12'x4' FTIBC 35 LF 12" CPEP STM @ 4.63% EXISTING GRADE OVER STORM LINE FINISHED GRADE OVER STORM LINE INLET: STA: 0+37.13, 0.00 IE: 416.50 36" (SW) IE: 422.09 12" (W) RIM: 425.42 CB-3 54" TYPE 2 CB CB-4 CB-5 CB-6 CB-8 CB-9 CB-10 CB-11 CB-12 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC STORM DRAINAGE PROFILES C3.2 1 H:1"=20' V:1"=4' STORM DRAINAGE PROFILE 1 2 H:1"=20' V:1"=4' STORM DRAINAGE PROFILE 2 3 H:1"=20' V:1"=4' STORM DRAINAGE PROFILE 3 4 H:1"=20' V:1"=4' STORM DRAINAGE PROFILE 4 1.SEE SHEETS C3.1 AND C5.3 FOR GENERAL STORM DRAINAGE NOTES. NOTE: R-395907 6 C5.4 1 C5.5 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 11.00'5.00'9.00'5.00'9.00'20 . 0 0 ' 24 . 0 0 ' 20 . 0 0 ' 7. 0 0 ' 30 . 0 '9.00'5.00'9.00'20'X ECECECFCX XECFC ECFCX X ECECECECR C E C X EC EC X X X X X RC2 RC2 X EC EC EC EC EC XX RC1 N 168167.69 E 1310173.90 N 168135.64 E 1310154.41N 168112.58 E 1310112.57 N 168115.10 E 1309967.46 N 168129.62 E 1309911.11 N 168153.37 E 1309866.29 N 168164.92 E 1309823.61 N 168165.45 E 1309810.80 N 168164.73 E 1309799.78 N 168182.24 E 1309800.39 N 168180.44 E 1309811.42 N 168166.41 E 1309897.22 N 168141.36 E 1310010.50 14.00'N 168158.57 E 1310050.17 R30.00' R48.00' N 168147.22 E 1310126.35 N 168319.96 E 1310231.26 R20.00' R10.00'N 168339.77 E 1310160.22 R4.00' N 168132.80 E 1310100.19 N 168288.71 E 1310247.49 R15.00' R34.00' N 168171.82 E 1310041.84 N 168163.68 E 1310026.36 N 168154.64 E 1310033.74 R4.00' R46.00' R20.00' N 168120.53 E 1310000.30R125.00' R100.00' R20.00' N 168184.30 E 1309882.68 15.00'14.00'12.00'12.00 ' N 168156.21 E 1310100.21 N 168145.83 E 1310117.31 N 168330.34 E 1310214.16 N 168344.87 E 1310213.39 R4.00' N 168325.31 E 1310226.32 X X R4.00' R15.00' N 168143.68 E 1309991.98 R20.00' N 168145.77 E 1309893.44 1 1 1A 2 2 3 3 3 4 5 6 6 7 9 8 9.2 12.00'9.2 10 10 8 8 8 8 11 11 11 11 11.1 11 11 12 12.1 12.2 13 13.2 13 13.1 9.00' TYP9.00' TYP9.00' TYP9.00' TYP33.7'RCRC2 X X X X RC 2 X RC2 X TCR C X X X X R C X X X N 168184.82 E 1310184.26 6.00' 14 X X R C X X RCCITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC N GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 PAVING & HORIZONTAL CONTROL PLAN C4.0 PROPOSED LEGEND: LIGHT DUTY CEMENT CONCRETE LIGHT DUTY ASPHALT CEMENT HEAVY DUTY ASPHALT CEMENT ASPHALT OVERLAY ALTERNATE BID ITEM 1 ASPHALT OVERLAY ALTERNATE BID ITEM 2 EC EXTRUDED CURB EXISTING CURB TO REMAIN FC 0" FLUSH CURB RC REPLACE EXISTING CURB IN KIND RC1 REPLACE EXISTING DAMAGED CURB IN KIND, ALTERNATE BID ITEM 1 RC2 REPLACE EXISTING DAMAGED CURB IN KIND, ALTERNATE BID ITEM 2 TC CEMENT CONCRETE TRAFFIC CURB CHANGE IN CURB TYPE COORDINATE AT CENTER OF ARC X N xxx E xxx KEYNOTES: ACCESSIBLE PARKING SIGN VAN ACCESSIBLE PARKING SIGN PAINTED CROSSWALK SIGN: "KEEP RIGHT" PER R4-7 OF THE WSDOT SIGN FABRICATION MANUAL SIGN: "LEFT TURN MUST TURN LEFT" PER R3-7L OF THE WSDOT SIGN FABRICATION MANUAL SIGN: "RIGHT TURN ONLY" PER R3-5R OF THE WSDOT SIGN FABRICATION MANUAL SIGN: "LEFT TURN ONLY" PER R3-5L OF THE WSDOT SIGN FABRICATION MANUAL AND "EXCEPT BUSES" PLACARD BELOW. SIGN: "DO NOT ENTER" PER R5-1 OF THE WSDOT SIGN FABRICATION MANUAL 4" SOLID WHITE PAINT LINE, TYP 4" DASHED WHITE PAINT LINE 4" DASHED WHITE PAINT LINE, ALTERNATE BID ITEM 2 4" SOLID YELLOW PAINT LINE TYPE 1S TRAFFIC ARROW (AHEAD) PER WSDOT STD PLAN M-24.40-02 TYPE 1S TRAFFIC ARROW (AHEAD) PER WSDOT STD PLAN M-24.40-02, ALTERNATE BID ITEM 1 TYPE 2SR TRAFFIC ARROW (RIGHT) PER WSDOT STD PLAN M-24.40-02 TYPE 2SR TRAFFIC ARROW (RIGHT) PER WSDOT STD PLAN M-24.40-02, ALTERNATE BID ITEM 1 TYPE 2SR TRAFFIC ARROW (RIGHT) PER WSDOT STD PLAN M-24.40-02, ALTERNATE BID ITEM 2 TYPE 2SL TRAFFIC ARROW (LEFT) PER WSDOT STD PLAN M-24.40-02 TYPE 2SL TRAFFIC ARROW (LEFT) PER WSDOT STD PLAN M-24.40-02, ALTERNATE BID ITEM 1 TYPE 2SL TRAFFIC ARROW (LEFT) PER WSDOT STD PLAN M-24.40-02, ALTERNATE BID ITEM 2 WHEELSTOP 1 1A 2 3 4 5 6 7 8 9 9.2 10 11 11.1 12 12.1 12.2 13 13.1 13.2 14 8 C5.12 C5.1 1 C5.1 3 C5.1 5 C5.1 4 C5.2 7 C5.1 5 C5.2 PLAN NOTES 1.PROTECT EXISTING CURBS AND PAVEMENT FROM DAMAGE DURING CONSTRUCTION. 2.ALL PAVEMENT ARROWS PER UNLESS OTHERWISE NOTED. 3.ALL SIGNS PER UNLESS OTHERWISE NOTED. 4 C5.1 4 C5.1 6 C5.1 3 C5.2 8 C5.1 R-395908 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC PAVING NOTES & DETAILS 1 C5.1 CRUSHED SURFACING TOP COURSE PER WSDOT 9.03-9(3) HMA CLASS 3/8", PG 64-22 4" CLASS 4000 CEMENT CONCRETE PAVEMENT 2.5"3"NOTES: 1.DEPTHS ARE COMPACTED THICKNESS. 2.DUMMY JOINTS CONSISTING OF 3/16" BE 2" PREMOLDED JOINT MATERIAL SHALL BE PLACED AT MAXIMUM 18 FOOT INTERVALS. 3.PROVIDE A TOOLED CONSTRUCTION JOINT AT MAXIMUM 6 FOOT INTERVAL. 4.THE CONTRACTOR SHALL EXPOSE EXISTING FILL, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER.3"10" MIN.NON-SHRINK GROUT 3:1 SAND & CEMENT (2) #6 BARS 9" 6'-0" 1" DIA HOLES 2" CLEARANCE (TYP) 4 1/2" (2) 3/4 BARS 10" MAX. 6" MIN. 3" MIN.GROUT 1" DEPTH NOTES: REFER TO PLAN FOR LOCATION OF WHEEL STOPS. PROPOSED GRADE AT FLOOR OF PARKING SPACE MIN.8"MIN. PERMIT REQUIRED STATE DISABLED PARKING PARKING RESERVED PARKING RESERVED CONCRETE 2" DIA GIP SCH 40 18"2.5'4"BOTTOM OF SIGN 5'12" 1" R (TYP) 2-1/2"5"1"2-1/2"6"10" ADHESIVE, SEE NOTE NOTE: THE ADHESIVE SHALL MEET THE REQUIREMENTS OF SECTION 9-26.1 FOR TYPE-II EPOXY BONDING AGENT DEPTH OF THRU JOINT 1-1/2" R (TYP) NOTES: 1.ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2.THE CONTRACTOR SHALL EXPOSE EXISTING FILL, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. NOTES: 1.ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2.THE CONTRACTOR SHALL EXPOSE EXISTING FILL, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. COMPACTED SUBGRADE TO 95% CRUSHED SURFACING BASE COURSE PER WSDOT 9.03-9(3)4"HMA CLASS 3/8", PG 64-22 CRUSHED SURFACING TOP COURSE PER WSDOT 9.03-9(3)2"GEOTEXTILE FABRIC GEOTEXTILE FABRIC 1 NOT TO SCALE LIGHT DUTY ASPHALT CEMENT PAVEMENT SECTION 2 NOT TO SCALE LIGHT DUTY CEMENT CONCRETE SIDEWALK SECTION 3 NOT TO SCALE HEAVY DUTY ASPHALT CEMENT PAVEMENT SECTION 5 NOT TO SCALE EXTRUDED CURB 6 NOT TO SCALE WHEELSTOP 8 NOT TO SCALE ACCESSIBLE PARKING SIGNAGE 3"CRUSHED SURFACING BASE COURSE PER WSDOT 9.03-9(3) 7 NOT TO SCALE CEMENT CONCRETE TRAFFIC CURB 5.5"1" 6.5" 1'-4" 8 1/4" 6" FACE OF CURB TOP OF PAVEMENT 1/2" R 1" R COMPACTED SUBGRADE TO 95% 6" MIN 6" PERFORATED PVC PIPE WHERE SHOWN ON PLAN GRAVEL BACKFILL FOR DRAINS WSDOT 9-03.12(4) 6" 6" MIN 6" GEOTEXTILE FABRIC COMPACTED SUBGRADE TO 95% 6" PERFORATED PVC PIPE WHERE SHOWN ON PLAN GRAVEL BACKFILL FOR DRAINS WSDOT 9-03.12(4) NOTES: 1.ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. HMA CLASS 3/8 INCH PG 64-22. WSDOT 5-04 EXISTING PAVEMENT EXISTING SUBGRADE2"PETROMAT FABRIC 4 NOT TO SCALE ASPHALT OVERLAY 16"16" R7-801A SIGN AT VAN ACCESSIBLE STALL ACCESSIBLE VAN R-395909 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC PAVING NOTES & DETAILS 2 C5.2 1 TYPICAL LONGITUDINAL PATCH AND OVERLAY FOR FLEXIBLE PAVEMENT NOT TO SCALE 2 TYPICAL TRANSVERSE PATCH FOR FLEXIBLE PAVEMENT NOT TO SCALE 3 SIGN MOUNTING ON SINGLE METAL POST NOT TO SCALE 4 THERMOPLASTIC PAINTED SIDEWALK NOT TO SCALE 5 PAVEMENT ARROWS NOT TO SCALE R-395910 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC DRAINAGE NOTES & DETAILS 1 C5.3 1 NOT TO SCALE CATCH BASIN TYPE 1 2 NOT TO SCALE CATCH BASIN TYPE 2 3 NOT TO SCALE CATCH BASIN INSTALLATION 4 NOT TO SCALE RECTANGULAR FRAME SURFACE WATER STANDARD PLAN NOTES AND CONSTRUCTION SEQUENCE 1.THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY. 2.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF RENTON PLAN REVIEW SECTION AND THE APPLICANT. 3.ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE (RMC), THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THIS PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4.APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION (E.G. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICAL. ETC.)THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN WITH THE CITY. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 5.A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6.GRADING ACTIVITIES (SITE ALTERATION) ARE LIMITED TO THE HOURS OF 7 A.M. TO 7 P.M. MONDAY THROUGH SATURDAY AND NO WORK ON SUNDAY IS ALLOWED, UNLESS OTHERWISE APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON. 7.IT SHALL BE THE APPLICANT’S/CONTRACTOR’S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE INITIATING OFF-SITE WORK. EASEMENTS REQUIRE CITY REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 8.FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS OF CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF RENTON. 9.DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 10.ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES MUST BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 11.ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95 PERCENT DENSITY, STANDARD PROCTOR. 12.OPEN CUTTING OF EXISTING ROADWAYS FOR NON-FRANCHISED UTILITY OR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY OF RENTON TRENCH RESTORATION STANDARDS. 13.ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITE EROSION HAS PASSED. 14.ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 15.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS “C”, WITH THE EXCEPTION OF PVC PIPE. 16.STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 17.ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE SOLID LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS. 18.BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES. 19.ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 20.ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 21.ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS-BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 22.DRAINAGE OUTLETS (STUB-OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR THOSE LOTS APPROVED FOR INFILTRATION BY THE CITY. STUB-OUTS SHALL CONFORM TO THE FOLLOWING: a.EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE DRAINS NECESSARY TO RENDER THE LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE FREE-FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORMWATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. b.OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE-FOOT-HIGH, 2" X 4" STAKE MARKED "STORM" OR "DRAIN". THE STUB-OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND BE SECURED TO THE STAKE. c.PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL AND, IF NON-METALLIC, THE PIPE SHALL BE PLACED IN A TRENCH WITH A TRACING WIRE ABOVE OR OTHER ACCEPTABLE DETECTION. d.PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. e.THE APPLICANT/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB-OUT CONVEYANCE LINES WITH RESPECT TO OTHER UTILITIES (E.G. POWER, GAS, TELEPHONE, TELEVISION). f.ALL INDIVIDUAL STUB-OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOME OWNER. g.STORM DRAINAGE PIPE SYSTEMS SHALL NOT PENETRATE BUILDING FOUNDATIONS, EXCEPT FOR SUMP PUMP DISCHARGE LINES USED TO DRAIN CRAWL SPACES, PROVIDED THE SUMP PUMP SYSTEM INCLUDES BACKFLOW PREVENTION OR A CHECK VALVE. 23.ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE MUST DEMONSTRATE ONE OF THE FOLLOWING: THE EXISTING DUFF LAYER SHALL BE STAGED AND REDISTRIBUTED TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL, OR; AMENDED SOIL SHALL BE ADDED TO MAINTAIN THE MOISTURE CAPACITY. 24.PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 25.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 26.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THEPERFORMANCE OF WORK. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 27.PROJECT LOCATED WITHIN THE AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE SURFACE WATER DESIGN MANUAL AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). R-395911 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC DRAINAGE NOTES & DETAILS 2 C5.4 1 NOT TO SCALE RECTANGULAR SOLID METAL COVER 2 NOT TO SCALE RECTANGULAR HERRINGBONE GRATE 3 NOT TO SCALE STORM ROUND FRAME AND COVER 4 NOT TO SCALE MISCELLANEOUS DETAILS FOR DRAINAGE STRUCTURES CAST IRON RING AND COVER 7-3/4" 15" 8" 7" 10" 8-3/4" 1-1/4" 1/2"2" 9" FIBRE JOINT PACKING 45° (1/8) BEND 2-7/8"4"2'-0" 12"Ø 5/8" 1'-0" NOTES: 1/2" 4-3/4" RAISE - 1/2" WIDE BORDER LETTERING: SEWER (SEWER) 3000 psi CLASS C CONCRETE (TYP.) STORM STORM (CO) 1. PIPE MATERIAL AS SPECIFIED BY THE ENGINEER. 2. PIPE DIAMETER AS SHOWN PER PLAN. PLUG TO BE SEALED IN SAME MANNER AS MAIN SEWER JOINTS 1" 1" 5 NOT TO SCALE STORM CLEANOUT R-395912 121° 97° 52° 36°54° 55° 129° 54° 122° PLAN AT ELEV 417.5 TO 419.1 PLAN AT ELEV 414.0 TO 415.1 6 SCALE 1"=5' CB-14 PLAN ℄ LADDER ℄ LADDER N N EXISTING 6" 12" CPEP EXISTING 12" EXISTING 6" 6" PVC 12" CPEP 12" CPEP DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 CB-2 CB-3 CB-4 CB-5 CB-6 CB-8 CB-9 CB-11 CB-12 CB-10 12.00' 8.00' TYP 50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%45 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%40 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%50 LF 60" CMP @ 0.00%DETENTION TANK ACCESS RISER, TYP CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC DRAINAGE NOTES & DETAILS 3 C5.5 3.0' IE=416.00 60"18"COVERMIN.EL=421.00 CROWN AT TYP NOTES: 1.ALL TANKS CMP, 5" X 1", (16 Ga.), AT S=0.0%. ALUMINIZED OR GALVANIZED WITH TREATMENTS 1, 2 OR 5. 36" CMP PIPE TO MANHOLE PER PLAN 6"MIN.2"Ø AIR VENT CONNECT TO CONTROL MANHOLE 0.5' DEAD STORAGE (TYP.) ACCESS RISER PER 3 C5.5 12" CMP IE: 416.50 TYP. 2 NOT TO SCALE DETENTION PIPE SYSTEM TYPICAL SECTION 4 NOT TO SCALE PIPE COMPACTION DESIGN AND BACKFILL (COR STD. PLAN 220.00) 1 NOT TO SCALE DETENTION PIPE SYSTEM PLAN 3'-0"INCREASE DEPTH AS REQUIRED TO MEET VERTICAL ELEVATION OF THE ACCESS RISER 12"6'-0"STEPS @ 12" O.C. LOAD TRANSFER SLAB 6" MIN. 6" MIN. 6'-0"2" CLR.CL 3'-8" 3'-0" PREFABRICATED LADDER (WSDOT STD. PLAN NO. B-30.90-01) ATTACH TO LOAD TRANSFER SLAB. TYPICAL FOR ALL PIPE TYPES PER PLAN EDGE OF SLAB SHALL EXTEND PAST EDGE OF TANK AND SHALL NOT REST ON PIPE BOLT-DOWN CIRCULAR FRAME AND COVER PER WSDOT STD PLAN B-30.70-03 4" STYROFOAM MAT CUTOUT @ LID OPENING CRUSHED SURFACING BASE P COURSE #5 @ 12" O.C. EACH WAY CONCRETE CONCRETE: 4000 PSI MIN. @ 28 DAYS 6 SACK MIX REBAR GRADE 60 36"Ø CMP RISER WELDED TO CMP DETENTION TANK FOR ADS N-12 PIPE, PROVIDE 36" RISER FUSED TO DETENTION TANK BY MANUFACTURER LADDER LATERAL SUPPORT SECURED TO PIPE OR RISER AS APPLICABLE, 4' MAX SPACING, MIN. 2 REQ'D 18" MAX 6" MIN NOTES: 1.LOAD TRANSFER SLAB IS REQUIRED ON RISERS LOCATED WITHIN PAVED AREAS. 2.LOAD TRANSFER SLAB SHALL BE OMITTED FROM RISERS LOCATED WITHIN RAINGARDEN AREAS. 3.ACCESS RISERS ARE SAME MATERIAL AS DETENTION TANKS. 4.ACCESS RISER SPACING IS 100' MAXIMUM. 5.ACCESS OPENING SHALL BE CLEARLY MARKED WITH CONFINED SPACE WARNING IN ACCORDANCE WITH OSHA REQUIREMENTS #5 @ 12" O.C. SHORT BARS TOP & BOTTOM (TYPICAL) (4) #5 TOP & BOTTOM LONG BARS (4) #5 TOP & BOTTOM LONG BARS #5 DIAGONALS TOP & BOTTOM HMA PAVEMENT 1/2" RADIUS BULLNOSE EDGE TYP. 4 SIDES 3 NOT TO SCALE DETENTION PIPE ACCESS RISER 3 C5.5 1 C5.6 6"6" PERF PVC WHERE SHOWN ON PLAN GRAVEL BACKFILL FOR DRAINS WSDOT 9-03.12(4) GEOTEXTILE FABRIC 16" UNO R-395913 5 C5.6 DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-3959LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS RENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSC17-002606LINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTSPR17-0002872215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 REVISED PER CITY COMMENTS BJS 7/7/17 SMC DRAINAGE NOTES & DETAILS 4 C5.6MIN.16"MAX.12" OUTLET PIPE PIPE SUPPORT(S): 3" X .090"2'-6" MIN.6"2'-0" MIN.ROUND SOLID COVER WITH LOCKING BOLTS. FRAME & LADDER OR STEPS OFFSET. SEE NOTE 8. FRAME & COVER ELEV. PER PLAN. STEPS OR LADDER MIN.4"MIN.INLET PIPE IE= 416.50 IE= 416.50 MANHOLE TYPE 2 NOTES: 1'-0"2'-0" MIN.CLEANOUT GATE: SHEAR GATE. SEE DETAIL 2 THIS SHEET. OVERFLOW ELEV.= 420.00 RESTRICTOR PLATE ORIFICE 1= 15/16" Ø ELEV.= 414.50 1.PIPE SIZES AND SLOPES: PER PLANS. 2.EXCEPT AS SHOWN OR NOTED, UNITS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS FOR CATCH BASIN TYPE 2, 60" MIN. DIAM. 3.PIPE SUPPORTS AND RESTRICTOR/SEPARATOR SHALL BE OF SAME MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY 5/8" DIAM. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2" IN WALL. 4.THE RESTRICTOR/SEPARATOR SHALL BE FABRICTED FROM 0.060" ALUMINUM, OR .064" ALUMINIZED STEEL, OR .064" GALVANIZED STEEL PIPE; IN ACCORDANCE WITH AASHTO M 36, M 196, M 197 AND M 274. GALVANIZED STEEL SHALL HAVE TREATMENT 1. 5.OUTLET SHALL BE CONNECTED TO STORM PIPE WITH A STANDARD COUPLING BAND FOR CORRUGATED METAL PIPE, OR GROUTED INTO THE BELL OF CONCRETE PIPE. 6.THE VERTICAL RISER STEM OF THE RESTICTOR/SEPARATOR SHALL BE THE SAME DIAM. AS THE HORIZONTAL OUTLET PIPE, WITH AN 12" MIN. DIAM. 7.FRAME AND LADDER OR STEPS OFFSET SO THAT: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 8.IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 9.MULTI-ORIFICE ELBOWS MAY BE LOCATED AS SHOWN OR ALL ON ONE SIDE OF RISER TO ASSURE LADDER CLEARANCE. 10.ACCESS OPENING SHALL BE CLEARLY MARKED WITH CONFINED SPACE WARNING IN ACCORDANCE WITH OSHA AND L&I REQUIREMENTS. 60" Ø (2) RESTRICTOR ELBOWS SEE DETAIL 3 RIM ELEV 423.26 RISER 12" 2"Ø AIR VENT IE= 420.75 EXTEND TO LANDSCAPE AREA FINISHED GRADE. MAX. W.S. 1 NOT TO SCALE CONTROL STRUCTURE (CB-12) SEE NOTE 5LEVEL LINEMAXIMUM OPENING OF GATE SIDE LIFT HANDLE LEVEL LINE FRONT NOTES: 1.SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26-ZG-32a OR CAST IRON ASTM A48 CLASS 30B AS REQUIRED. 2.GATE SHALL BE 8" DIAM. UNLESS OTHERWISE SPECIFIED. 3.GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE), WELDING, OR OTHER SECURE MEANS. 4.LIFT ROD: AS SPECIFIED BY MFR. WITH HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD. 5.GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE. 6.NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. 7.MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT. 8.FLANGE MOUNTING BOLTS SHALL BE 3/8" DIAM. STAINLESS STEEL. 9.ALTERNATE CLEANOUT/SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE AND HAVE A SIX BOLT, 10 3/8" BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION. ALTERNATE SHALL BE REVIEWED AND APPROVED BY ENGINEER. HANDLE WITH LOCK PIN. ADJUSTABLE LOCK HOOK WITH LOCK SCREW. 1" ROD OR TUBING, VARIABLE LENGTH. LIFT HANDLE SHALL BE ATTACHED PER MANUFACTURER'S RECOMMENDATIONS. SIX EVENLY SPACED HOLES ON 10 3/8" BOLT CIRCLE FOR BOLTING TO FLANGE CONNECTION. 2 NOT TO SCALE SHEAR GATE 6" MAX. RESTRICTOR ELBOW DETAIL NOT TO SCALE ORIFICE=1/2"Ø (ORIFICE 2) ORIFICE=1 1/8"Ø (ORIFICE 3) REMOVABLE WATERTIGHT COUPLING IE=418.30 (ORIFICE 2) IE=419.00 (ORIFICE 3) RISER 4 NOT TO SCALE FILTERRA VAULT FILTERRA INSTALLATIONS ID SIZE CONFIGURATION NOTES FILTERRA 1 10'x6'LONG SIDE CURB INLET FILTERRA 2 4'x4'SQUARE CURB INLET SEE NOTE 3 FILTERRA 3 12'x4'LONG SIDE CURB INLET NOTES: 1.SEE PLAN FOR LOCATIONS. 2.SEE PLANTING PLAN FOR PLANTINGS IN FILTERRA VAULTS. 3.FILTERRA 2 SHALL BE INSTALLED WITH AN ADA-COMPLAINT GRATE AND PLANTED WITH GRASSES. INLET ELEVATION PER PLAN 6" TOP ELEVATION PER PLAN AS SPECIFIED IN PLANTING PLAN R-395914 6" PIPE 5 NOT TO SCALE CMP PIPE CONNECTION 3 NOT TO SCALE RESTRICTOR ELBOW DEVELOPMENT ENGINEERING IFitz-James 07/21/2017 SURFACE WATER UTILITY rstraka 07/21/2017