HomeMy WebLinkAbout180301_Sartori ES_4th and Park Overflow Revisions Dual 8-Inch Pipe.pdfFIRE LANE NO PARKINGF I RE LANE NO PARKING DSDSDST29+7430+0031+0024+00 25+00 26+00 27+00 28+00 36 SDCB 37 SDCB 24 20 LF 12" DIP @ 0.50% 12' CONCRETE SIDEWALK PER COR STD. PLAN 102 CONCRETE CURB AND GUTTER PER COR STD. PLANS 101 AND 103 4'x4' CONCRETE ENCASING FOR FUTURE UNDERGROUND ELECTRICAL CONDUIT. SDCB 57 SDCB 54 23 LF 12 " D I P @ 1.33 % SEE SHEET C4.1 FOR NEW WATER MAIN, FIRE HYDRANT, AND SERVICES, TYP. STA:24+89.84, 21.0' RT ANGLE POINT SDCB 1 IE: 30.75 SDCB 77 IE: 30.60 37 34 LF 12" CPEP @ 0.50% 3 (2) 53 LF 8" DI @ 0.50% SDCB 71 34 LF 12" DI @ 0.50% 5 4 SDCB 78 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 23+5036.1636.2124+0036.1336.0224+5035.9035.7825+0035.6535.5125+5035.3735.2326+0035.0826+50 27+00 27+50 28+0023+5036.1636.2124+0036.1336.0224+5035.9035.7825+0035.6535.5125+5035.3735.2326+0035.0826+50 27+00 27+50 28+00 0.23%0.48% 0.57% GRADE BREAK STA = 23+80.57 ELEV = 36.227 GRADE BREAK STA = 24+97.39 ELEV = 35.670 GRADE BREAK STA = 26+14.45 ELEV = 35.00136.936.336.336.236.036.035.935.835.635.535.335.2EXISTING GRADE ELEVATION @ CENTERLINE FINISHED GRADE ELEVATION @ FLOWLINE EXISTING / FINISHED GRADE ELEVATION @ SAWCUT LINE EXIST. STCB 2255 EXIST. 16" D.I. WATER MAIN EXIST. GRADE @ SAWCUT LINE EXIST. GRADE @ CENTERLINE FINISHED GRADE @ FLOWLINE NEW 6" WATER NEW 6" WATER NEW 1.5" WATER NEW 4" WATER NEW 8" WATER NEW 6" WATER VERTICAL SCALE: 1"=2' 4'x4' CONCRETE ENCASING FOR FUTURE UNDERGROUND ELECTRICAL CONDUIT. STA 24+14.69, 20.92' RT IE: 31.89 12" (W) RIM: 36.03 SDCB 57 CB TYPE 1 23 LF 12" DIP @ 1.33% SDCB 37 STA 30+36.82, 10.45' RT RIM: 35.73 IE: 30.33 12" (SE) IE: 30.33 12" (S) 48" TYPE 2 CB SOLID LID TOP OF EX. 4" PWR=33.15 BOTTOM=32.82 TOP OF EX. 2" PWR (2)=33.10 BOTTOM=32.93 EX. 22" SANITARY SEWER SDCB 71 STA 27+35.26, 15.18' LT RIM: 35.33 IE: 30.98 12" (W) IE: 30.98 12" (E) IE: 33.33 12" (S) 48" TYPE 2 CB OVER BUILD CATCH BASIN PROVIDE ETHAFOAM PAD 53 LF 8" DI @ 0.50% STA: 27+35.42, 20.87 LT IE: 30.93 12" CPEP (E) IE: 30.90 12" CPEP (N) RIM: 35.08 STCB 6238, EX. TYPE 1 CB SDCB 54 CB TYPE 1 STA 26+20.31, 29.41' RT RIM: 34.94 IE: 30.63 12" (N) SDCB 24 CB TYPE 1 STA 26+38.78, 55.68' RT RIM: 35.43 IE: 30.43 12" (SE) IE: 30.43 12" (NW) SDCB 1169 STA 26+48.07, 18.94' LT RIM: 35.77 IE: 34.00 8" DI (N) (2 PIPES) (NEW) IE: 27.97 8" CONC. (W) IE: 27.97 8" CONC. (E) IE: 29.07 12" CPEP (S) EX. TYPE 2 CB REMOVE EX. LADDER & PROVIDE NEW LADDER AS DIRECTED BY THE CITY TOP OF EX. PWR=32.02 BOTTOM=30.90 TOP OF EX. PWR=33.66 SDCB 78 STA 27+01.49, 16.64' LT RIM: 35.50 IE: 33.73 8" (S) IE: 33.50 12" (N) CB TYPE 1L 34 LF 12" DI @ 0.50% 53 LF 8" DI @ 0.50% (2 PIPES) CITY OF RENTON SARTORI ELEMENTARY SCHOOL RENTON SCHOOL DISTRICTSARTORI ELEMENTARY SCHOOLLUA16-000692U16-006798PR16-0002152215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB T A C O M A SEATTLE SPOKANE TRI-CITIESKnow what's below. before you dig.Call R 1 ADDENDUM NO. 1 WJF 3/1/17 WJF 2 ADDENDUM NO. 3 WJF 3/17/17 WJF 3 CITY COMMENTS WJF 4/21/17 WJF 4 STORM DRAINAGE REVISIONS WJF 12/13/17 WJF 5 RAMP REVISION WJF 2/22/18 WJF PARK AVENUE NORTH FRONTAGE IMPROVEMENTS C6.3NGRAPHIC SCALE 0 20 40 1" = 20 FEET 10MATCH LINE STA 23+50 - SEE SHEET C6.2PARK AVENUE NORTH NORTH 4TH STREET1 C7.9 KEYNOTES CROSS WALK PUSH BUTTON FOR ACCESSIBLE PEDESTRIAN SIGNAL, SEE SIGNAL DESIGN FOR EXACT LOCATION. TYPICAL TRANSVERSE PATCH FOR FLEXIBLE PAVEMENT, SEE DETAIL 4 ON SHEET C7.10, TYP. REPLACE TRAFFIC LOOPS IN ACCORDANCE WITH CITY STANDARDS. COORDINATE LOOP REPLACEMENT WITH TRANSPORTATION MAINTENANCE DIVISION. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL DETERMINE IF THE WATER LINE IS ABANDONED. IF THE LINE IS ACTIVE A TYPE 1 CB SHALL BE USED. IF ABANDONED THE LINE SHALL BE CUT AND CAPPED TO ALLOW TYPE 2 CB INSTALLATION. TWO SIDE BY SIDE 8" DUCTILE IRON PIPES AT THE SAME ELEVATION. 1 2 3 4 5 1 1TED-40-3930R-393021 22 2 2 STA:26+14.36, 30.3' RT POINT OF TANGENCY 5 5 5 02/23/2018 sdcb 78 shall have a rectangular solid metal cover per cor std. plan 204.10. IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING IFitz-James 03/01/2018