HomeMy WebLinkAbout181008-revisions-3-inch-meter-detail-320.4.pdfREGISTER SHALL BE TOUCH READ PIT LID 4" POST INDICATOR VALVE TR -PL) AND BE INTELLIGENT COMMUNICATION (MJxMJ) PAINTED BLUE ENCODER TYPE (ICE). METER MUST READ IN 2-3/4" SHACKLE RODS PER CITYCU. FT. OF RENTON SPECIFICATIONS 4" 90° BEND (MJ) L4" END (MJ) IN TEST 2"x2" TEE (MJxFL) 12.. 13 LF 4" D.I.NIPPLE WITH w GATE VALVE (FLxMJ) 0 7'-0" ESILIENT BRASS GATE AND 2" PLUG. LADDER W4" FLxMJ ADAPTOR J SUPPORT BARS 2, - ADAPTORPEROSHA 4" or 6" D.I. TO BUILDING FLOW EPDXY NON -SHRINK GROUT • 2'-4" 4" TEE (MJxFL) — J WELDED STEEL COLLAR TOUCH READ PIT LID SENSOR MOUNTED ON STEEL PLATE COVER THROUGH 2" DIA. DRILLED HOLE IN COVER. LOCATE HOLE 2Y2" FROM EDGE OF PIT LID AND RIBS. PRECAST CONCRETE VAULT WITH 2 3"x3" HINGED STEEL PLATE COVER. OUTSIDE DIMENSIONS 4'-8"x7'-0". EQUAL TO PIPE INC., OR UTILITY VAULT WITH 57 -7L -B, 2 3'x3' DIAMOND PLATE DOORS) 6",4" OR 3" GATE VALVE (FLxFL) NON -RISING STEM WITH HAND WHEEL EQUAL TO MUELLER CO.A-2380-6. 6" OR 4" (FLxPE) CEMENT LINED DUCTILE IRON PIPE CLASS 52 3'-6" LONG WITH COLLAR 20" FROM P.E. EQUAL TO THOSE SUPPLIED BY PACIFIC S' 4" WATER WORKS CO. INC. 12" AROUND- 4" TEE FL) CITY PRIVATE PIPING PIPING DEADMAN BLOCK REQUIRED WITH SHACKLING TO TEE SENSUS MODEL 520R RADIO wQ91 READ PIT SET SENSOR MOUNTED ON STEEL PLATETWO PIECE CAST IRON VALVE BOX, COVER THROUGH 2" DIA. EQUAL TO OLYMPIC FOUNDRY CO. DRILLED HOLE IN COVER STANDARD 8" TOP SECTION, WITH REGULAR BASE SECTION LENGTH TO FI' 6",4" OR 3" COMPOUND WATER METER (FL) J EQUAL TO SENSUS SRII COMPOUND METER WITH TOUCHREAD PITUD I.C.E. REGISTER & SENSOR WITH 4 WHEEL HIGH RESOLUTION (100 CUBIC ADJUSTABLE STEEL FEET) REGISTER. FOR 3" METER, REDUCE AT PIPE SUPPORT METER WITH 4"X3" FLxFL CONCENTRIC STANCHION BOLTED REDUCER. TO FLOOR e7IIaI11113maIII l26*3 ALL METERS AND BACKFLOW PREVENTION DEVICE COMBINATIONS ARE NOT SHOWN OR INCLUDED IN THE STANDARD DETAIL DRAWINGS. IF YOUR PARTICULAR COMBINATION IS NOT SHOWN, AN APPROVED DRAWING WILL BE REQUIRED BY THE UTILITY ENGINEERING DEPT. FOR ITS INSTALLATION. THE PRINCIPAL REQUIREMENTS REGARDING VAULT SIZING ARE THE LENGTH OF FITTINGS OR THEIR CLEARANCE FROM THE VAULT WALLS, WHICH CLEARANCE SHALL BE A MINIMUM OF 12" FROM THE ENDS AND THE SIDE CLEARANCE SHOULD BE AS TYPICALLY SHOWN ON THE VARIOUS STANDARD DETAILS). NOTE: DEADMAN BLOCK SHALL BE DESIGNED AND INSTALLED SO IT BEARS AGAINST SUFFICIENT UNDISTURBED EARTH SO AS TO SUPPORT THE DESIGNED THRUST. VALVE NUT EXTENSION IF REQUIRED DWG BR46/PAGE 8090) 6", 4" OR 3" GATE VALVE FLxMJ) EQUAL TO MUELLER CO. A-2380-20. TO BUILDING CITY PRIVAI PIPING PIPING 6" OR 4" PExPE CEMENT LINED DUCTILE IRON PIPE CLASS 52. LENGTH TO FIT. 6" OR 4" FLEXIBLE FLANGED COUPLING ADAPTOR, ROMAC OR APPROVED EQUAL. ZY er< + PUBLIC WORKS 3", 4" & 6" COMPOUND DOMESTIC STD. PLAN — 320.4 O DEPARTMENT WATER METER ASSEMBLY N,yp MARCH 2010 wQ91 III II IJP ' 1 7 e S 6",4" OR 3" COMPOUND WATER METER (FL) J EQUAL TO SENSUS SRII COMPOUND METER WITH TOUCHREAD PITUD I.C.E. REGISTER & SENSOR WITH 4 WHEEL HIGH RESOLUTION (100 CUBIC ADJUSTABLE STEEL FEET) REGISTER. FOR 3" METER, REDUCE AT PIPE SUPPORT METER WITH 4"X3" FLxFL CONCENTRIC STANCHION BOLTED REDUCER. TO FLOOR e7IIaI11113maIII l26*3 ALL METERS AND BACKFLOW PREVENTION DEVICE COMBINATIONS ARE NOT SHOWN OR INCLUDED IN THE STANDARD DETAIL DRAWINGS. IF YOUR PARTICULAR COMBINATION IS NOT SHOWN, AN APPROVED DRAWING WILL BE REQUIRED BY THE UTILITY ENGINEERING DEPT. FOR ITS INSTALLATION. THE PRINCIPAL REQUIREMENTS REGARDING VAULT SIZING ARE THE LENGTH OF FITTINGS OR THEIR CLEARANCE FROM THE VAULT WALLS, WHICH CLEARANCE SHALL BE A MINIMUM OF 12" FROM THE ENDS AND THE SIDE CLEARANCE SHOULD BE AS TYPICALLY SHOWN ON THE VARIOUS STANDARD DETAILS). NOTE: DEADMAN BLOCK SHALL BE DESIGNED AND INSTALLED SO IT BEARS AGAINST SUFFICIENT UNDISTURBED EARTH SO AS TO SUPPORT THE DESIGNED THRUST. VALVE NUT EXTENSION IF REQUIRED DWG BR46/PAGE 8090) 6", 4" OR 3" GATE VALVE FLxMJ) EQUAL TO MUELLER CO. A-2380-20. TO BUILDING CITY PRIVAI PIPING PIPING 6" OR 4" PExPE CEMENT LINED DUCTILE IRON PIPE CLASS 52. LENGTH TO FIT. 6" OR 4" FLEXIBLE FLANGED COUPLING ADAPTOR, ROMAC OR APPROVED EQUAL. ZY er< + PUBLIC WORKS 3", 4" & 6" COMPOUND DOMESTIC STD. PLAN — 320.4 O DEPARTMENT WATER METER ASSEMBLY N,yp MARCH 2010 4" GATE VALVE (MJ xMJ) NON-RISING STEM WITH HANDWHEEL AND WITH 2-3/4"SHACKLE RODS THROUGH VAULT WALL TO BYPASS TEE xxxxxxxxxxxxxxxxxxxxxWATER UTILITY Abdoul Gafour 10/05/2018 REVISED DETAIL APPROVED BY: FOR PROJECT CC; TOM MAIN, ANN FOWLER