Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutRS_ Approved Seattle Pipe Trades DRAINAGE REPORT (TIR) U15005192_PR15000025-FLATTENED.pdfSeattle 425-753-1869 Portland 971-295-6441
SEATTLE PIPE TRADES ADDITION
595 MONSTER RD SW
RENTON, WASHINGTON
Prepared Exclusively for Seattle Pipe Trades by:
Novadyne Civil Engineers
(425) 753-1869
15
April 8, 2015June 19, 2015
January 6, 2017 Rev.
February 23, 2017 Rev.
March 15, 2017 Rev.
March 23, 2017 Rev.
May 31, 2017 Rev.
Civil Engineers
NOVAdyne
U15005192
SURFACE WATER UTILITY
rstraka 06/01/2017
DEVELOPMENT ENGINEERING
rnair 06/08/2017
TABLE OF CONTENTS
1.0 PROJECT OVERVIEW ................................................................................................................. 1
2.0 CONDITIONS AND REQUIREMENTS SUMMARY ................................................................. 2
2.1 Analysis of the Eight Core Requirements ............................................................................... 2
2.2 Analysis of the Five Special Requirements ............................................................................ 3
3.0 OFF-SITE ANALYSIS .................................................................................................................... 5
3.1 Upstream Drainage .................................................................................................................... 5
3.2 Downstream Drainage Course ................................................................................................. 5
4.0 ANALYSIS AND DESIGN ............................................................................................................. 6
4.1 Existing Site Hydrology ............................................................................................................. 6
4.2 Developed Site Hydrology ........................................................................................................ 6
4.3 Flow Control ................................................................................................................................ 7
4.4 Water Quality .............................................................................................................................. 7
4.5 Flood Plain................................................................................................................................... 7
5.0 CONVEYANCE SYSTEM ANALYSIS AND DESIGN ................................................................ 9
6.0 SPECIAL REPORTS AND STUDIES ....................................................................................... 10
7.0 OTHER PERMITS ........................................................................................................................ 11
8.0 ESC ANALYSIS AND DESIGN .................................................................................................. 12
9.0 BOND QUANTITIES, FACILITY SUMMARIES, AND DECLARATION OF COVENANT . 13
10.0 OPERATIONS AND MAINTENANCE MANUAL ..................................................................... 14
GEOTECHNICAL REPORT............................................................................................................101
Page 1
1.0 PROJECT OVERVIEW
The Seattle Pipe Trades Addition is located at the Seattle Pipe Trades facility in the
City of Renton Washington at 595 Monster RD SW andlies within Section 24, Township 23 North, Range 4
East. Please refer to the Vicinity Map within this section for a depiction of the project
site.
The project site is currently an undeveloped grassed area just west of an existing
parking lot. The surrounding properties are the Boeing Building 25-01 to the north,
Oakesdale Avenue Southwest to the east, vacant land owned by Boeing to the south,
and existing stormwater ponds and mitigated wetlands to the west. According to the City
of Renton soils maps, the on-site soils consist of Puget Silty Clay Loam, also known as
till soils. The site is located within the 100-year floodplain per current adopted FIRM
mapping. No regulated wetlands currently exist on site. The site is also located within a
Seismic Hazard Area according to the City of Renton mapping.
The project area drains to the north through an existing 12-inch culvert to existing
stormwater ponds that were constructed as a part of the Boeing Company Surface
Water Management Project in 1999. The site is within the Black River Basin, also a part
of the Duwamish-Green watershed.
The parking lot expansion area will incorporate permeable paving to provide stormwater
treatment, storage, and infiltration. WWHM was used to model the permeable pavement
section. The 8-inch base will provide stormwater storage, while the stormwater infiltrates
into the underlying soils. Surface runoff from the permeable pavement is not anticipated
and will only occur in the event that the porous asphalt pores get clogged or a storm
event that exceeds the 100 year model. The permeable pavement section has been
modeled to infiltrate the entire 100-year developed storm event. The parking area
expansion will minimize impacts to the existing floodplain and will not reduce the
effective storage volume within the floodplain. The onsite stormwater facilities will be
designed in accordance with the 2009 King County Surface Water Design Manual
(KCSWDM), 2012 Low Impact Development Technical Guidance Manual for Puget
Sound, and the City of Renton Amendments to the KCSWDM.
The Seattle Pipe Trades Addition is located at the Seattle Pipe Trades facility in the City
of Renton Washington at 595 Monster RD SW and lies within Section 24, Township 23
North, Range 4 East. Please refer to the Vicinity Map within this section for a depiction
of the project site.
Seattle Area Pipe Trades is proposing to add an 11,900SF addition to the current
53,400sf Building on the south side of the building located at 595 Monster Rd SW
Renton, WA 98057
Parcel 240324-9122
County of King, State of Washington.
This will require relocation of some utilities and expansion of parking to the south of the
5.53 Acre Site. The neighboring property Owner has agreed to sell additional area and/or
possibly grant construction and slope easements to allow additional parking to be
developed.
According to the City of Renton soils maps, the on-site soils consist of Puget Silty Clay
Loam, however the Geotech Report indicates alluvial soils in the area of pavement so we
have modeled this as outwash A/B . The site is located within the 100-year floodplain
per current adopted FIRM mapping. No regulated wetlands currently exist on site. The
site is also located adjacent to a Seismic Hazard Area according to the City of Renton
mapping. The project area drains to the north through an existing 12-inch culvert to
existing stormwater ponds that were constructed as with the original building
construction. The site is within the Green River Basin, also a part of the
Duwamish-Green watershed.
The parking lot expansion area will incorporate permeable paving to provide stormwater
treatment, storage, and infiltration. WWHM was used to model the permeable pavement
section. The 8-inch base will provide stormwater storage, while the stormwater infiltrates
into the underlying soils. Surface runoff from the permeable pavement is not anticipated
and will only occur in the event that the porous asphalt pores get clogged or a storm
event that exceeds the 100 year model. The permeable pavement section has been
modeled to infiltrate the entire 100-year developed storm event. The parking area
expansion will minimize impacts to the existing floodplain and will not reduce the
effective storage volume within the floodplain. The onsite stormwater facilities will be
designed in accordance with the 2009 King County Surface Water Design Manual
(KCSWDM), 2012 Low Impact Development Technical Guidance Manual for Puget
Sound, and the City of Renton Amendments to the KCSWDM. We have designed and
verified the facilities using the WWHM2012 analysis tools according to the Washington
Department of Ecology WWHM2012 amended in DEC 2014. Criteria is Peak Rate Flow
Control matching existing flows.
Page 2
2.0 CONDITIONS AND REQUIREMENTS SUMMARY
The project is subject to Full Drainage Review as dictated by the KCSWDM and the City
of Renton Amendments to the KCSWDM. Core Requirements No. 1 through 8 and
Special Requirements No. 1 through 5 are described below:
2.1 Analysis of the Eight Core Requirements
Core Requirement No. 1: Discharge at the Natural Location.
The intent of this requirement is to “prevent adverse impacts to downstream
properties caused by diversion of flow from one flowpath to another, and to
discharge in a manner that does not significantly impact downhill properties or
drainage systems,” KCWSWDM pages 1-19.
The existing site drains to northerly to the existing onsite stormwater facilities and
is then conveyed easterly into Springbrook Creek. The ultimate discharge
location for the site will remain unchanged. Stormwater runoff will be infiltrated
with the use of permeable paving.
Core Requirement No. 2: Off-Site Analysis.
The intent of this requirement is to identify and evaluate off-site flooding and
erosion problems that may be created or aggravated by the proposed project and
to ensure appropriate measures are provided for preventing creation or
aggravation of those problems.
This project is proposing to infiltrate stormwater runoff with the use of permeable
paving. This will result in lower peak flows from the site; therefore, no off-site
flooding or erosion problems will be created or aggravated by this project. Based
on these conditions, an offsite analysis is not required.
Core Requirement No. 3: Flow Control.
The intent is to ensure the minimum level of control needed to protect
downstream properties and resources from increases in peak, duration, and
volume of runoff generated by new development.
This site is located within a Peak Rate Flow Control zone according to the City of
Renton flow control map. A reduction in peak flows is expected as a result of the
development. This is because the proposed permeable paving system will
infiltrate of all stormwater runoff within the development area.
Core Requirement No. 4: Conveyance System.
The intent of this requirement is to ensure proper design and construction of
engineered conveyance system elements.
New conveyance systems are designed to convey the developed 100-year peak
storm event.
The existing site drains to northerly to the existing onsite stormwater facilities and
is then conveyed southwesterly to Green River. The ultimate discharge location
for the site will remain unchanged. Stormwater runoff will be infiltrated with the
use of permeable paving.
There is no discharge from the pavement to any underground conveyance systems.
The new building addition will discharge to the 12" conveyance pipes which are
relocated around the addition resulting in less flow due to the elimination of the
existing parking lot flow to the existing CB's and Private Storm Conveyance
System.
See the analysis that
occurs
follows under the WWHM Calcs Section.
Page 3
Core Requirement No. 5: Temporary Erosion and Sediment Control.
The intent of this requirement is to prevent the transport of sediment and other
impacts, such as increased runoff, related to land disturbing activities.
A Temporary Erosion and Sedimentation Control (TESC) Plan has been
prepared as part of the Civil Plan Set. The TESC Plan will control the transport
of sediment to downstream surface waters and adjacent properties in
accordance with all the applicable standards of the KCWSWDM and the City of
Renton.
Core Requirement No. 6: Maintenance and Operations.
The intent is to ensure that the maintenance responsibility for drainage facilities
is clearly assigned and that these facilities will be properly maintained and
operated in perpetuity.
Operations and Maintenance instructions are included in Section 10.0.
Core Requirement No. 7: Financial Guarantees and Liability.
This requirement is intended to ensure financial guarantees are posted to
sufficiently cover the cost of correcting, if necessary, incomplete or substandard
drainage facility construction work, and to warrant for two years the satisfactory
performance and maintenance of those newly-constructed drainage facilities to
be assumed by the City of Renton for maintenance and operation.
All applicable guarantees will be provided for the project. The bond quantities are
included in Section 9.0 of this report.
Core Requirement No. 8: Water Quality.
The intent of the water quality requirement is "to require an efficient, cost-
effective level of water quality treatment tailored to the sensitivities and resource
protection needs of the downstream receiving water to which the project site
drains." and "Core Requirement No. 8 requires that water quality treatment
facilities be provided to remove pollutants from runoff discharging from the
project site."
Stormwater treatment will be provided via a soil treatment layer beneath the
permeable paving section.
2.2 Analysis of the Five Special Requirements
Special Requirement No. 1: Other Adopted Area-Specific Requirements.
The following is a list of other possible adopted area-specific requirements
according to the KCWSWDM:
Critical Drainage Areas – This development is not located within a critical
drainage area.
All new and replaced paving will be permeable asphalt with infiltration and WQ filtration.
See soils report for soils characteristics and Section 4.0 below.
Thus the PGIS area is reduced from existing roughly 22,000sf. See areas in the Exhibits.
No sediment runoff shall go outside project limits during construction.
Stormwater flow control BMP Covenant draft is provided in this TIR.
Six
Page 4
Master Drainage Plan – The area is not part of a master drainage plan.
Basin Plans – This project does not fall into any specified basin plan.
Salmon Conservation Plan – A Salmon Conservation Plan does not apply to this
development.
Lake Management Plan – It does not appear that there is a Lake Management
Plan that impacts the proposed development.
Flood Hazard Reduction Plan Updates – It does not appear that the flood hazard
reduction plan adversely affects the proposed development.
Shared Facility Drainage Plan – The project does not propose to connect to a
shared detention facility system or create a shared facility. This plan does not
apply.
Special Requirement No. 2: Flood Hazard Area Delineation.
The proposed site is located within the 100-year floodplain of Springbrook Creek.
The base flood elevation identified by FEMA is approximately 19.0 (datum in
NGVD 29). Based on a review of current survey information, the 100-year
floodplain corresponds to elevation 22.5 (datum in NAVD 88). Please refer to the
included FIRM map.
Special Requirement No. 3: Flood Protection Facilities.
Special Requirement No. 3 is not applicable to the proposed site because the
site does not meet either of the conditions set forward in the 2009 KCWSWDM:
· Contains or is adjacent to a Class 1 or 2 stream that has an existing flood
protection facility (such as a levee, revetment, or berm).
· Proposed to construct a new or to modify an existing flood protection
facility.
The design of the site will not affect any existing flood protection facilities.
Special Requirement No. 4: Source Control.
Special Requirement No. 4 will be met through a variety of on-site source control
BMPs. This includes the good housekeeping practices and maintenance.
Special Requirement No. 5: Oil Control.
The proposed parking area is not classified as a high use site as defined in the
KCSWDM.
Special Requirement No. 6: Aquifer Protection AreaNot applicable.
FEMA elevation certificate is required for building addition.
Page 5
3.0 OFF-SITE ANALYSIS
3.1 Upstream Drainage
There is an upstream basin of approximately 1.3-acres that drains to the project
site. The upstream area will be collected and routed around the proposed parking
lot expansion and is therefore considered negligible and has no impact on the
proposed development.
3.2 Downstream Drainage Course
The existing downstream drainage course for the project area starts at the
existing 12-inch culvert at the northern portion of the project site. This culvert
conveys flows to the north and runoff then flows to the northwest into the existing
storm drainage and mitigated wetland system. Runoff then flows to the east in a
series of culverts and ditches, until entering Springbrook Creek approximately
one half mile downstream from the project site.
This project is proposing to infiltrate stormwater runoff from the proposed parking
expansion area with the use of permeable pavement. Infiltration of stormwater
runoff will result in a reduction of peak flows to the downstream area; therefore,
no off-site flooding or erosion problems will be created or aggravated by this
project. Based on these conditions, an offsite analysis is not required.
There is no uptream drainage onto the site. Drainage off the hillside to the south
drains to the existing seasonal pond that is offsite. We maintain the runoff from
this hillside to it's natural direction.
Existing Drainage from the Building and parking lot is collected into a system of
12" storm drains and Catch Basins and conveyed to the North to a Storm Facility
then southwesterly to a Regional Pump Station where it is pumped to the River.
This project is proposing to infiltrate stormwater runoff from the proposed parking
expansion area with the use of permeable pavement. Infiltration of stormwater
runoff will result in a reduction of peak flows to the downstream area; therefore,
no off-site flooding or erosion problems will be created or aggravated by this
project. Based on these conditions, an offsite analysis is not required.
The expanded parking area will be Permeable Pavement and infiltrate.
Page 6
4.0 ANALYSIS AND DESIGN
4.1 Existing Site Hydrology
According to the City of Renton soils maps, the on-site soils consist of Puget Silty
Clay Loam, also known as till soils. The site is has slopes ranging from 1 percent
to 3 percent, tending to the north. The site is currently a vacant grassed area.
Per the City of Renton Amendment to the KCSWDM, the existing site conditions
are those that existed prior to 1979. During that time, the site existed as a portion
of the Longacres Racetrack per aerial photography and has been modeled as till
grass. Please see Pre-Developed Basin Map for the existing site conditions.
Runoff from the predeveloped site sheet flows northerly until entering a 12-inch
culvert, is then conveyed to the northwest into the existing stormwater system,
and eventually discharges into Springbrook Creek one half mile downstream
from the site.
The predeveloped peak flows are as follows (from WWHM output):
Q2= 0.095 cfs
Q10= 0.236 cfs
Q100= 0.494 cfs
4.2 Developed Site Hydrology
The proposed construction of the parking lot, sidewalk and internal landscaping
will utilize permeable paving to infiltrate stormwater runoff. The proposed
improvements cover approximately 1.21-acres of the site. The site will be graded
within a 1.5 percent slope to the west. An interceptor swale will be constructed
along the west to intercept any runoff that may occur during an emergency event
(i.e. soil saturation or permeable pavement failure). The existing land use cover
was modeled as till grass. The geotechnical report by Geo Engineers found that
the factored underlying soils support a 0.25 inches/hour infiltration rate. Please
see the Developed Conditions Exhbit.
Site Area = 1.21 acres
Assume all is permeable pavement = 1.21 acres
Pervious Area (landscaping) will infiltrate into the permeable subsurface
therefore will be modeled as permeable pavement
Assuming that infiltration is not possible the peak flows would be:
Q2= 0.54 cfs
Q10= 0.78 cfs
The existing Parking Lot drains to existing Catch Basins and 12" Storm Drains that
convey the water to the north to the facility constructed for the existing building.
The railroad spur and area south of the Site currently drain to the south to a
seasonal swale and pond.
The expansion to the south as well as replacement of existing pavement will be
regraded to avoid impacts to the floodwater volumes and impervious areas
replaced with pervious asphalt pavement to provide water quality treatment and
infiltration for groundwater recharge, an LID, Low Impact Development Technique.
The wetland is identified and classified along with the 25ft buffer as shown on the
plans. No work to be done within this buffer or wetland.
4.2 Developed Site Hydrology
The area to the south of the existing parking is landscaped area and will be parking
area with pervious asphalt and landscaping.
Page 7
Q100= 1.11 cfs
4.3 Flow Control
Permeable paving, a Low Impact Development (LID) technique, is proposed to
mitigate for the increased stormwater from new impervious surfaces constructed
on site. The permeable pavement section has been modeled with WWHM 2012,
which has the ability to model permeable pavement. The in accordance with the
KCSWDM guidance and will infiltrate the full developed 100-year peak storm
event.
The permeable paving section was modeled over the entire area. The
permeable paving layer thickness is 0.25 feet with a pavement porosity of 0.20 or
20 percent. The choker course thickness is 0.17 feet and has an assumed 0.20
porosity. The base course (storage) is 0.67 feet and has a conservative 0.30
porosity or 30 percent voids within the aggregate base storage bed. The soil
layer was modeled with a 0.25 inch/hour infiltration to be confirmed by the Geo
Engineers.
The modeled permeable pavement basin will infiltrate 100 percent of storm event.
4.4 Water Quality
This site is subject to Enhanced Basic Water Quality treatment since it is a
commercial property. The site is exempt from providing a traditional water quality
treatment facility since the project’s stormwater runoff will be infiltrated into
subsurface soils. The subsurface soils will act as a soil treatment layer, which
meet the groundwater protection criteria per the City of Renton Surface Water
Design Manual Amendment.
The criteria are outlined as follows:
1) The first 2 feet or more of soil beneath the infiltration facility has a cation
exchange capacity greater than 5 and an organic content of greater than
0.5%, AND
2) The soil must have a measured infiltration rate of less than or equal to 12
inches per hour.
The project will infiltrate 100 percent of the stormwater runoff into the subsurface
soils, which meets the treatment criteria. Please refer to the calculations within
this section and included soil reports in Section 6.0 for values regarding cation
exchange, organic content, and infiltration rates.
4.5 Flood Plain
Review of the King County Flood Insurance Rate Map (Firm) #53033C0976 F,
found that the site is within the 100-year flood Zone AH. Much of the site is below
the 100-year flood elevation contour of 19.0. The site will be graded to minimize
Permeable paving, a Low Impact Development (LID) technique, is proposed to
mitigate for the increased stormwater from new paving constructed on site.
The permeable pavement section has been modeled with WWHM 2012,
which has the ability to model permeable pavement. This is in accordance with the
KCSWDM guidance and will infiltrate the full developed 100-year peak storm
event. Technically, there is less impervious area and reduced PGIS that exempts
this project however the development was modeled to prove the results.
The permeable paving section was used over the entire area of new pavement.
There are two Points of Compliance shown on the maps below and each analyzed.
The modeled permeable pavement basin will infiltrate 100 percent of storm event and
both points of compliance pass.
Page 8
impact within the flood plain. We have created additional floodwater volume
by excavating into the hillside to the south.
Volumes below the flood plain (elev=22.58'):
EG = 1394 CF
FG = 1313 CF
Thus the new grades created additional Flood Plain Volume.
PROPOSED GRADING MODEL
EXISTING GRADING MODEL
impact within the flood plain. We have created additional floodwater volumeby excavating into the hillside to the south.
POINT OFCOMPLIANCE 1POINT OFCOMPLIANCE 2
POINT OFCOMPLIANCE 1POINT OFCOMPLIANCE 2
WWHM2012
PROJECT REPORT
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 2
General Model Information
Project Name:Seattle Pipe Trades 2017-02-21
Site Name:Seattle Pie Trades
Site Address:595 SW Monster RD
City:Renton
Report Date:3/21/2017
Gage:Seatac
Data Start:1948/10/01
Data End:2009/09/30
Timestep:15 Minute
Precip Scale:1.000
Version Date:2016/11/23
Version:4.2.13
POC Thresholds
Low Flow Threshold for POC1:100 Percent of the 2 Year
High Flow Threshold for POC1:50 Year
Low Flow Threshold for POC2:100 Percent of the 2 Year
High Flow Threshold for POC2:50 Year
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 3
Landuse Basin Data
Predeveloped Land Use
Disturbed Area
Bypass:No
GroundWater:No
Pervious Land Use acre
A B, Lawn, Flat 0.1
Pervious Total 0.1
Impervious Land Use acre
PARKING FLAT 0.5
Impervious Total 0.5
Basin Total 0.6
Element Flows To:
Surface Interflow Groundwater
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 4
Basin 2 SOUTH DRAINAGE
Bypass:No
GroundWater:No
Pervious Land Use acre
A B, Forest, Steep 0.22
A B, Pasture, Mod 0.45
Pervious Total 0.67
Impervious Land Use acre
Impervious Total 0
Basin Total 0.67
Element Flows To:
Surface Interflow Groundwater
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 5
Mitigated Land Use
Basin 1
Bypass:Yes
GroundWater:No
Pervious Land Use acre
Pervious Total 0
Impervious Land Use acre
ROADS FLAT 0.18
Impervious Total 0.18
Basin Total 0.18
Element Flows To:
Surface Interflow Groundwater
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 6
Basin 2 South Drainage
Bypass:Yes
GroundWater:No
Pervious Land Use acre
A B, Forest, Steep 0.22
A B, Pasture, Mod 0.18
Pervious Total 0.4
Impervious Land Use acre
Impervious Total 0
Basin Total 0.4
Element Flows To:
Surface Interflow Groundwater
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 7
Routing Elements
Predeveloped Routing
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 8
Mitigated Routing
Permeable Pavement 1
Pavement Area:0.5730 acre.Pavement Length: 60.00 ft.
Pavement Width: 416.00 ft.
Pavement slope 1:0.02 To 1
Pavement thickness: 0.25
Pour Space of Pavement: 0.2
Material thickness of second layer: 0.167
Pour Space of material for second layer: 0.2
Material thickness of third layer: 0.67
Pour Space of material for third layer: 0.3
Infiltration On
Infiltration rate:0.3
Infiltration safety factor:1
Total Volume Infiltrated (ac-ft.):84.141
Total Volume Through Riser (ac-ft.):0
Total Volume Through Facility (ac-ft.):84.141
Percent Infiltrated:100
Total Precip Applied to Facility:0
Total Evap From Facility:5.904
Element Flows To:
Outlet 1 Outlet 2
Permeable Pavement Hydraulic Table
Stage(feet)Area(ac.)Volume(ac-ft.)Discharge(cfs)Infilt(cfs)
0.0000 0.573 0.000 0.000 0.000
0.0120 0.574 0.002 0.000 0.173
0.0241 0.576 0.004 0.000 0.173
0.0361 0.578 0.006 0.000 0.173
0.0481 0.579 0.008 0.000 0.173
0.0602 0.581 0.010 0.000 0.173
0.0722 0.583 0.012 0.000 0.173
0.0842 0.584 0.014 0.000 0.173
0.0963 0.586 0.016 0.000 0.173
0.1083 0.588 0.018 0.000 0.173
0.1203 0.589 0.021 0.000 0.173
0.1324 0.591 0.023 0.000 0.173
0.1444 0.592 0.025 0.000 0.173
0.1564 0.594 0.027 0.000 0.173
0.1685 0.596 0.029 0.000 0.173
0.1805 0.597 0.031 0.000 0.173
0.1925 0.599 0.033 0.000 0.173
0.2046 0.601 0.036 0.000 0.173
0.2166 0.602 0.038 0.000 0.173
0.2286 0.604 0.040 0.000 0.173
0.2407 0.606 0.042 0.000 0.173
0.2527 0.607 0.044 0.000 0.173
0.2647 0.609 0.047 0.000 0.173
0.2768 0.611 0.049 0.000 0.173
0.2888 0.612 0.051 0.000 0.173
0.3008 0.614 0.053 0.000 0.173
0.3129 0.616 0.055 0.000 0.173
0.3249 0.617 0.058 0.000 0.173
0.3369 0.619 0.060 0.000 0.173
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 9
0.3490 0.621 0.062 0.000 0.173
0.3610 0.622 0.064 0.000 0.173
0.3730 0.624 0.067 0.000 0.173
0.3851 0.626 0.069 0.000 0.173
0.3971 0.627 0.071 0.000 0.173
0.4091 0.629 0.073 0.000 0.173
0.4212 0.631 0.076 0.000 0.173
0.4332 0.632 0.078 0.000 0.173
0.4452 0.634 0.080 0.000 0.173
0.4573 0.636 0.082 0.000 0.173
0.4693 0.637 0.085 0.000 0.173
0.4813 0.639 0.087 0.000 0.173
0.4934 0.641 0.089 0.000 0.173
0.5054 0.642 0.092 0.000 0.173
0.5174 0.644 0.094 0.000 0.173
0.5295 0.646 0.096 0.000 0.173
0.5415 0.647 0.099 0.000 0.173
0.5535 0.649 0.101 0.000 0.173
0.5656 0.651 0.103 0.000 0.173
0.5776 0.652 0.106 0.000 0.173
0.5896 0.654 0.108 0.000 0.173
0.6017 0.656 0.110 0.000 0.173
0.6137 0.657 0.113 0.000 0.173
0.6257 0.659 0.115 0.000 0.173
0.6378 0.661 0.118 0.000 0.173
0.6498 0.662 0.120 0.000 0.173
0.6618 0.664 0.122 0.000 0.173
0.6739 0.666 0.124 0.000 0.173
0.6859 0.667 0.126 0.000 0.173
0.6979 0.669 0.127 0.000 0.173
0.7100 0.671 0.129 0.000 0.173
0.7220 0.672 0.130 0.000 0.173
0.7340 0.674 0.132 0.000 0.173
0.7461 0.676 0.134 0.000 0.173
0.7581 0.677 0.135 0.000 0.173
0.7701 0.679 0.137 0.000 0.173
0.7822 0.681 0.139 0.000 0.173
0.7942 0.682 0.140 0.000 0.173
0.8062 0.684 0.142 0.000 0.173
0.8183 0.686 0.144 0.000 0.173
0.8303 0.687 0.145 0.000 0.173
0.8423 0.689 0.147 0.000 0.173
0.8544 0.691 0.148 0.000 0.173
0.8664 0.692 0.150 0.000 0.173
0.8784 0.694 0.152 0.000 0.173
0.8905 0.696 0.154 0.000 0.173
0.9025 0.697 0.155 0.000 0.173
0.9145 0.699 0.157 0.000 0.173
0.9266 0.701 0.159 0.000 0.173
0.9386 0.702 0.160 0.000 0.173
0.9506 0.704 0.162 0.000 0.173
0.9627 0.706 0.164 0.000 0.173
0.9747 0.707 0.165 0.000 0.173
0.9867 0.709 0.167 0.000 0.173
0.9988 0.711 0.169 0.000 0.173
1.0108 0.712 0.170 0.000 0.173
1.0228 0.714 0.172 0.000 0.173
1.0349 0.716 0.174 0.000 0.173
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 10
1.0469 0.717 0.176 0.000 0.173
1.0589 0.719 0.177 0.000 0.173
1.0710 0.721 0.179 0.000 0.173
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 11
Permeable Pavement 2
Pavement Area:0.1415 acre.Pavement Length: 268.00 ft.
Pavement Width: 23.00 ft.
Pavement slope 1:0.02 To 1
Pavement thickness: 0.25
Pour Space of Pavement: 0.3
Material thickness of second layer: 0.167
Pour Space of material for second layer: 0.2
Material thickness of third layer: 0.67
Pour Space of material for third layer: 0.3
Infiltration On
Infiltration rate:0.3
Infiltration safety factor:1
Total Volume Infiltrated (ac-ft.):20.766
Total Volume Through Riser (ac-ft.):0
Total Volume Through Facility (ac-ft.):20.766
Percent Infiltrated:100
Total Precip Applied to Facility:0
Total Evap From Facility:1.458
Element Flows To:
Outlet 1 Outlet 2
Permeable Pavement Hydraulic Table
Stage(feet)Area(ac.)Volume(ac-ft.)Discharge(cfs)Infilt(cfs)
0.0000 0.141 0.000 0.000 0.000
0.0120 0.148 0.000 0.000 0.042
0.0241 0.156 0.001 0.000 0.042
0.0361 0.163 0.001 0.000 0.042
0.0481 0.171 0.002 0.000 0.042
0.0602 0.178 0.002 0.000 0.042
0.0722 0.185 0.003 0.000 0.042
0.0842 0.193 0.004 0.000 0.042
0.0963 0.200 0.004 0.000 0.042
0.1083 0.208 0.005 0.000 0.042
0.1203 0.215 0.006 0.000 0.042
0.1324 0.222 0.007 0.000 0.042
0.1444 0.230 0.008 0.000 0.042
0.1564 0.237 0.008 0.000 0.042
0.1685 0.245 0.009 0.000 0.042
0.1805 0.252 0.010 0.000 0.042
0.1925 0.260 0.011 0.000 0.042
0.2046 0.267 0.012 0.000 0.042
0.2166 0.274 0.013 0.000 0.042
0.2286 0.282 0.014 0.000 0.042
0.2407 0.289 0.015 0.000 0.042
0.2527 0.297 0.016 0.000 0.042
0.2647 0.304 0.017 0.000 0.042
0.2768 0.311 0.018 0.000 0.042
0.2888 0.319 0.020 0.000 0.042
0.3008 0.326 0.021 0.000 0.042
0.3129 0.334 0.022 0.000 0.042
0.3249 0.341 0.023 0.000 0.042
0.3369 0.348 0.024 0.000 0.042
0.3490 0.356 0.026 0.000 0.042
0.3610 0.363 0.027 0.000 0.042
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 12
0.3730 0.371 0.028 0.000 0.042
0.3851 0.378 0.030 0.000 0.042
0.3971 0.385 0.031 0.000 0.042
0.4091 0.393 0.032 0.000 0.042
0.4212 0.400 0.034 0.000 0.042
0.4332 0.408 0.035 0.000 0.042
0.4452 0.415 0.037 0.000 0.042
0.4573 0.422 0.038 0.000 0.042
0.4693 0.430 0.040 0.000 0.042
0.4813 0.437 0.041 0.000 0.042
0.4934 0.445 0.043 0.000 0.042
0.5054 0.452 0.045 0.000 0.042
0.5174 0.459 0.046 0.000 0.042
0.5295 0.467 0.048 0.000 0.042
0.5415 0.474 0.050 0.000 0.042
0.5535 0.482 0.051 0.000 0.042
0.5656 0.489 0.053 0.000 0.042
0.5776 0.496 0.055 0.000 0.042
0.5896 0.504 0.057 0.000 0.042
0.6017 0.511 0.059 0.000 0.042
0.6137 0.519 0.060 0.000 0.042
0.6257 0.526 0.062 0.000 0.042
0.6378 0.533 0.064 0.000 0.042
0.6498 0.541 0.066 0.000 0.042
0.6618 0.548 0.068 0.000 0.042
0.6739 0.556 0.069 0.000 0.042
0.6859 0.563 0.071 0.000 0.042
0.6979 0.571 0.072 0.000 0.042
0.7100 0.578 0.073 0.000 0.042
0.7220 0.585 0.075 0.000 0.042
0.7340 0.593 0.076 0.000 0.042
0.7461 0.600 0.078 0.000 0.042
0.7581 0.608 0.079 0.000 0.042
0.7701 0.615 0.081 0.000 0.042
0.7822 0.622 0.082 0.000 0.042
0.7942 0.630 0.084 0.000 0.042
0.8062 0.637 0.085 0.000 0.042
0.8183 0.645 0.087 0.000 0.042
0.8303 0.652 0.088 0.000 0.042
0.8423 0.659 0.091 0.000 0.042
0.8544 0.667 0.093 0.000 0.042
0.8664 0.674 0.095 0.000 0.042
0.8784 0.682 0.098 0.000 0.042
0.8905 0.689 0.100 0.000 0.042
0.9025 0.696 0.103 0.000 0.042
0.9145 0.704 0.105 0.000 0.042
0.9266 0.711 0.108 0.000 0.042
0.9386 0.719 0.111 0.000 0.042
0.9506 0.726 0.113 0.000 0.042
0.9627 0.733 0.116 0.000 0.042
0.9747 0.741 0.118 0.000 0.042
0.9867 0.748 0.121 0.000 0.042
0.9988 0.756 0.124 0.000 0.042
1.0108 0.763 0.127 0.000 0.042
1.0228 0.770 0.129 0.000 0.042
1.0349 0.778 0.132 0.000 0.042
1.0469 0.785 0.135 0.000 0.042
1.0589 0.793 0.138 0.000 0.042
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 13
1.0710 0.800 0.141 0.000 0.042
Seattle Pipe Trades 2017-02-21 3/21/2017 9:03:38 PM Page 14
Analysis Results
POC 1
+ Predeveloped x Mitigated
Predeveloped Landuse Totals for POC #1
Total Pervious Area:0.1
Total Impervious Area:0.5
Mitigated Landuse Totals for POC #1
Total Pervious Area:0
Total Impervious Area:0.18
Flow Frequency Method:Log Pearson Type III 17B
Flow Frequency Return Periods for Predeveloped. POC #1
Return Period Flow(cfs)
2 year 0.191283
5 year 0.24207
10 year 0.276627
25 year 0.321503
50 year 0.355884
100 year 0.391128
Flow Frequency Return Periods for Mitigated. POC #1
Return Period Flow(cfs)
2 year 0.068628
5 year 0.086685
10 year 0.098953
25 year 0.114867
50 year 0.127047
100 year 0.139523
Annual Peaks
Annual Peaks for Predeveloped and Mitigated. POC #1
Year Predeveloped Mitigated
1949 0.247 0.089
1950 0.267 0.096
1951 0.157 0.056
1952 0.137 0.049
1953 0.148 0.053
1954 0.156 0.056
1955 0.176 0.063
1956 0.173 0.062
1957 0.196 0.071
1958 0.158 0.057
Seattle Pipe Trades 2017-02-21 3/21/2017 9:04:16 PM Page 15
1959 0.161 0.058
1960 0.159 0.057
1961 0.168 0.060
1962 0.146 0.053
1963 0.163 0.058
1964 0.159 0.057
1965 0.203 0.073
1966 0.135 0.049
1967 0.233 0.084
1968 0.265 0.095
1969 0.184 0.066
1970 0.178 0.064
1971 0.212 0.076
1972 0.225 0.079
1973 0.132 0.048
1974 0.193 0.070
1975 0.223 0.080
1976 0.150 0.054
1977 0.162 0.058
1978 0.198 0.071
1979 0.271 0.098
1980 0.244 0.088
1981 0.199 0.072
1982 0.281 0.101
1983 0.229 0.082
1984 0.144 0.052
1985 0.199 0.072
1986 0.172 0.062
1987 0.266 0.096
1988 0.161 0.058
1989 0.202 0.073
1990 0.360 0.122
1991 0.277 0.098
1992 0.143 0.051
1993 0.124 0.045
1994 0.135 0.048
1995 0.177 0.064
1996 0.193 0.068
1997 0.185 0.066
1998 0.185 0.067
1999 0.379 0.136
2000 0.189 0.068
2001 0.207 0.075
2002 0.242 0.087
2003 0.188 0.068
2004 0.354 0.128
2005 0.162 0.058
2006 0.145 0.051
2007 0.331 0.119
2008 0.269 0.096
2009 0.246 0.089
Ranked Annual Peaks
Ranked Annual Peaks for Predeveloped and Mitigated. POC #1
Rank Predeveloped Mitigated
1 0.3786 0.1363
2 0.3599 0.1275
3 0.3542 0.1223
Seattle Pipe Trades 2017-02-21 3/21/2017 9:04:16 PM Page 16
4 0.3311 0.1192
5 0.2809 0.1011
6 0.2767 0.0977
7 0.2715 0.0977
8 0.2693 0.0960
9 0.2668 0.0960
10 0.2658 0.0957
11 0.2648 0.0953
12 0.2474 0.0889
13 0.2464 0.0887
14 0.2435 0.0877
15 0.2415 0.0869
16 0.2329 0.0838
17 0.2286 0.0823
18 0.2250 0.0801
19 0.2226 0.0787
20 0.2118 0.0763
21 0.2070 0.0745
22 0.2029 0.0728
23 0.2017 0.0726
24 0.1992 0.0717
25 0.1988 0.0716
26 0.1983 0.0714
27 0.1962 0.0706
28 0.1932 0.0696
29 0.1930 0.0678
30 0.1886 0.0677
31 0.1882 0.0676
32 0.1850 0.0666
33 0.1849 0.0663
34 0.1841 0.0657
35 0.1776 0.0639
36 0.1767 0.0636
37 0.1758 0.0633
38 0.1730 0.0623
39 0.1723 0.0620
40 0.1676 0.0603
41 0.1628 0.0584
42 0.1621 0.0584
43 0.1619 0.0583
44 0.1615 0.0581
45 0.1613 0.0581
46 0.1591 0.0573
47 0.1586 0.0570
48 0.1583 0.0570
49 0.1572 0.0558
50 0.1561 0.0555
51 0.1499 0.0539
52 0.1482 0.0533
53 0.1460 0.0526
54 0.1452 0.0519
55 0.1443 0.0515
56 0.1428 0.0514
57 0.1373 0.0494
58 0.1352 0.0486
59 0.1346 0.0484
60 0.1324 0.0477
61 0.1237 0.0445
Seattle Pipe Trades 2017-02-21 3/21/2017 9:04:16 PM Page 17
Seattle Pipe Trades 2017-02-21 3/21/2017 9:04:16 PM Page 18
Duration Flows
The Facility PASSED
Flow(cfs)Predev Mit Percentage Pass/Fail
0.1913 111 0 0 Pass
0.1929 110 0 0 Pass
0.1946 106 0 0 Pass
0.1963 104 0 0 Pass
0.1979 98 0 0 Pass
0.1996 93 0 0 Pass
0.2013 89 0 0 Pass
0.2029 87 0 0 Pass
0.2046 86 0 0 Pass
0.2062 83 0 0 Pass
0.2079 77 0 0 Pass
0.2096 76 0 0 Pass
0.2112 72 0 0 Pass
0.2129 70 0 0 Pass
0.2146 66 0 0 Pass
0.2162 65 0 0 Pass
0.2179 63 0 0 Pass
0.2195 62 0 0 Pass
0.2212 60 0 0 Pass
0.2229 55 0 0 Pass
0.2245 55 0 0 Pass
0.2262 53 0 0 Pass
0.2279 53 0 0 Pass
0.2295 51 0 0 Pass
0.2312 50 0 0 Pass
0.2328 49 0 0 Pass
0.2345 46 0 0 Pass
0.2362 46 0 0 Pass
0.2378 44 0 0 Pass
0.2395 41 0 0 Pass
0.2412 40 0 0 Pass
0.2428 36 0 0 Pass
0.2445 34 0 0 Pass
0.2462 32 0 0 Pass
0.2478 30 0 0 Pass
0.2495 29 0 0 Pass
0.2511 29 0 0 Pass
0.2528 29 0 0 Pass
0.2545 26 0 0 Pass
0.2561 24 0 0 Pass
0.2578 24 0 0 Pass
0.2595 22 0 0 Pass
0.2611 21 0 0 Pass
0.2628 21 0 0 Pass
0.2644 19 0 0 Pass
0.2661 17 0 0 Pass
0.2678 16 0 0 Pass
0.2694 14 0 0 Pass
0.2711 14 0 0 Pass
0.2728 13 0 0 Pass
0.2744 12 0 0 Pass
0.2761 12 0 0 Pass
0.2777 10 0 0 Pass
Seattle Pipe Trades 2017-02-21 3/21/2017 9:04:16 PM Page 19
0.2794 9 0 0 Pass
0.2811 8 0 0 Pass
0.2827 8 0 0 Pass
0.2844 8 0 0 Pass
0.2861 8 0 0 Pass
0.2877 8 0 0 Pass
0.2894 8 0 0 Pass
0.2910 8 0 0 Pass
0.2927 8 0 0 Pass
0.2944 8 0 0 Pass
0.2960 8 0 0 Pass
0.2977 8 0 0 Pass
0.2994 8 0 0 Pass
0.3010 8 0 0 Pass
0.3027 8 0 0 Pass
0.3043 8 0 0 Pass
0.3060 8 0 0 Pass
0.3077 8 0 0 Pass
0.3093 8 0 0 Pass
0.3110 8 0 0 Pass
0.3127 8 0 0 Pass
0.3143 8 0 0 Pass
0.3160 7 0 0 Pass
0.3176 7 0 0 Pass
0.3193 7 0 0 Pass
0.3210 7 0 0 Pass
0.3226 7 0 0 Pass
0.3243 6 0 0 Pass
0.3260 6 0 0 Pass
0.3276 6 0 0 Pass
0.3293 6 0 0 Pass
0.3309 6 0 0 Pass
0.3326 5 0 0 Pass
0.3343 5 0 0 Pass
0.3359 5 0 0 Pass
0.3376 4 0 0 Pass
0.3393 4 0 0 Pass
0.3409 4 0 0 Pass
0.3426 4 0 0 Pass
0.3442 4 0 0 Pass
0.3459 3 0 0 Pass
0.3476 3 0 0 Pass
0.3492 3 0 0 Pass
0.3509 3 0 0 Pass
0.3526 3 0 0 Pass
0.3542 3 0 0 Pass
0.3559 2 0 0 Pass
Seattle Pipe Trades 2017-02-21 3/21/2017 9:04:16 PM Page 20
Water Quality
Water Quality BMP Flow and Volume for POC #1
On-line facility volume:0 acre-feet
On-line facility target flow:0 cfs.
Adjusted for 15 min:0 cfs.
Off-line facility target flow:0 cfs.
Adjusted for 15 min:0 cfs.
Seattle Pipe Trades 2017-02-21 3/21/2017 9:04:16 PM Page 21
LID Report
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:06 PM Page 22
POC 2
+ Predeveloped x Mitigated
Predeveloped Landuse Totals for POC #2
Total Pervious Area:0.67
Total Impervious Area:0
Mitigated Landuse Totals for POC #2
Total Pervious Area:0.4
Total Impervious Area:0.714509
Flow Frequency Method:Log Pearson Type III 17B
Flow Frequency Return Periods for Predeveloped. POC #2
Return Period Flow(cfs)
2 year 0.000652
5 year 0.001563
10 year 0.002664
25 year 0.004999
50 year 0.007767
100 year 0.011819
Flow Frequency Return Periods for Mitigated. POC #2
Return Period Flow(cfs)
2 year 0.000344
5 year 0.000785
10 year 0.001298
25 year 0.002351
50 year 0.003564
100 year 0.005296
Annual Peaks
Annual Peaks for Predeveloped and Mitigated. POC #2
Year Predeveloped Mitigated
1949 0.000 0.000
1950 0.011 0.005
1951 0.003 0.001
1952 0.000 0.000
1953 0.000 0.000
1954 0.000 0.000
1955 0.000 0.000
1956 0.003 0.001
1957 0.000 0.000
1958 0.000 0.000
1959 0.000 0.000
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 23
1960 0.001 0.001
1961 0.002 0.001
1962 0.000 0.000
1963 0.000 0.000
1964 0.001 0.001
1965 0.000 0.000
1966 0.000 0.000
1967 0.001 0.000
1968 0.000 0.000
1969 0.001 0.000
1970 0.000 0.000
1971 0.000 0.000
1972 0.007 0.004
1973 0.000 0.000
1974 0.000 0.000
1975 0.000 0.000
1976 0.000 0.000
1977 0.000 0.000
1978 0.000 0.000
1979 0.000 0.000
1980 0.000 0.000
1981 0.000 0.000
1982 0.001 0.000
1983 0.000 0.000
1984 0.000 0.000
1985 0.000 0.000
1986 0.000 0.000
1987 0.000 0.000
1988 0.000 0.000
1989 0.000 0.000
1990 0.001 0.001
1991 0.002 0.001
1992 0.000 0.000
1993 0.000 0.000
1994 0.000 0.000
1995 0.001 0.001
1996 0.016 0.008
1997 0.002 0.001
1998 0.000 0.000
1999 0.003 0.001
2000 0.000 0.000
2001 0.000 0.000
2002 0.000 0.000
2003 0.000 0.000
2004 0.000 0.000
2005 0.000 0.000
2006 0.000 0.000
2007 0.030 0.014
2008 0.001 0.000
2009 0.000 0.000
Ranked Annual Peaks
Ranked Annual Peaks for Predeveloped and Mitigated. POC #2
Rank Predeveloped Mitigated
1 0.0303 0.0140
2 0.0156 0.0075
3 0.0109 0.0046
4 0.0070 0.0037
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 24
5 0.0031 0.0015
6 0.0030 0.0014
7 0.0027 0.0013
8 0.0023 0.0011
9 0.0020 0.0010
10 0.0016 0.0007
11 0.0015 0.0007
12 0.0012 0.0005
13 0.0012 0.0005
14 0.0012 0.0005
15 0.0008 0.0003
16 0.0008 0.0003
17 0.0006 0.0003
18 0.0005 0.0003
19 0.0005 0.0003
20 0.0005 0.0003
21 0.0005 0.0003
22 0.0005 0.0003
23 0.0005 0.0003
24 0.0005 0.0003
25 0.0005 0.0003
26 0.0005 0.0003
27 0.0005 0.0003
28 0.0005 0.0003
29 0.0005 0.0003
30 0.0005 0.0003
31 0.0005 0.0003
32 0.0005 0.0003
33 0.0005 0.0003
34 0.0005 0.0003
35 0.0005 0.0003
36 0.0005 0.0003
37 0.0005 0.0003
38 0.0005 0.0003
39 0.0005 0.0003
40 0.0005 0.0003
41 0.0005 0.0003
42 0.0005 0.0003
43 0.0005 0.0003
44 0.0005 0.0003
45 0.0005 0.0003
46 0.0005 0.0003
47 0.0005 0.0003
48 0.0005 0.0003
49 0.0005 0.0003
50 0.0004 0.0002
51 0.0004 0.0002
52 0.0004 0.0002
53 0.0004 0.0002
54 0.0004 0.0002
55 0.0004 0.0002
56 0.0004 0.0002
57 0.0004 0.0002
58 0.0004 0.0002
59 0.0004 0.0002
60 0.0004 0.0002
61 0.0004 0.0002
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 25
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 26
Duration Flows
The Facility PASSED
Flow(cfs)Predev Mit Percentage Pass/Fail
0.0007 142 55 38 Pass
0.0007 130 51 39 Pass
0.0008 115 46 40 Pass
0.0009 103 41 39 Pass
0.0009 94 35 37 Pass
0.0010 88 32 36 Pass
0.0011 77 30 38 Pass
0.0012 70 26 37 Pass
0.0012 64 26 40 Pass
0.0013 62 23 37 Pass
0.0014 56 22 39 Pass
0.0014 53 20 37 Pass
0.0015 52 16 30 Pass
0.0016 50 16 32 Pass
0.0017 50 14 28 Pass
0.0017 47 13 27 Pass
0.0018 43 11 25 Pass
0.0019 40 11 27 Pass
0.0019 36 11 30 Pass
0.0020 36 11 30 Pass
0.0021 30 11 36 Pass
0.0022 30 11 36 Pass
0.0022 29 11 37 Pass
0.0023 27 11 40 Pass
0.0024 27 11 40 Pass
0.0024 27 11 40 Pass
0.0025 27 10 37 Pass
0.0026 26 10 38 Pass
0.0027 26 10 38 Pass
0.0027 24 10 41 Pass
0.0028 24 10 41 Pass
0.0029 22 10 45 Pass
0.0030 20 10 50 Pass
0.0030 19 10 52 Pass
0.0031 18 10 55 Pass
0.0032 16 9 56 Pass
0.0032 16 9 56 Pass
0.0033 15 9 60 Pass
0.0034 15 9 60 Pass
0.0035 11 9 81 Pass
0.0035 11 9 81 Pass
0.0036 11 9 81 Pass
0.0037 11 9 81 Pass
0.0037 11 8 72 Pass
0.0038 11 8 72 Pass
0.0039 11 7 63 Pass
0.0040 11 7 63 Pass
0.0040 11 7 63 Pass
0.0041 11 7 63 Pass
0.0042 11 7 63 Pass
0.0042 11 7 63 Pass
0.0043 11 7 63 Pass
0.0044 11 7 63 Pass
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 27
0.0045 11 7 63 Pass
0.0045 11 6 54 Pass
0.0046 10 5 50 Pass
0.0047 10 5 50 Pass
0.0047 10 5 50 Pass
0.0048 10 5 50 Pass
0.0049 10 5 50 Pass
0.0050 10 5 50 Pass
0.0050 10 5 50 Pass
0.0051 10 5 50 Pass
0.0052 10 5 50 Pass
0.0053 10 5 50 Pass
0.0053 10 5 50 Pass
0.0054 10 5 50 Pass
0.0055 10 5 50 Pass
0.0055 10 5 50 Pass
0.0056 10 5 50 Pass
0.0057 10 5 50 Pass
0.0058 10 5 50 Pass
0.0058 10 5 50 Pass
0.0059 10 5 50 Pass
0.0060 10 5 50 Pass
0.0060 10 5 50 Pass
0.0061 10 5 50 Pass
0.0062 10 4 40 Pass
0.0063 10 4 40 Pass
0.0063 10 4 40 Pass
0.0064 10 4 40 Pass
0.0065 10 4 40 Pass
0.0065 10 4 40 Pass
0.0066 10 4 40 Pass
0.0067 10 4 40 Pass
0.0068 10 4 40 Pass
0.0068 10 4 40 Pass
0.0069 10 4 40 Pass
0.0070 9 4 44 Pass
0.0070 8 4 50 Pass
0.0071 8 4 50 Pass
0.0072 8 4 50 Pass
0.0073 8 4 50 Pass
0.0073 8 4 50 Pass
0.0074 8 4 50 Pass
0.0075 8 3 37 Pass
0.0076 8 2 25 Pass
0.0076 8 2 25 Pass
0.0077 8 2 25 Pass
0.0078 8 2 25 Pass
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 28
Water Quality
Water Quality BMP Flow and Volume for POC #2
On-line facility volume:0 acre-feet
On-line facility target flow:0 cfs.
Adjusted for 15 min:0 cfs.
Off-line facility target flow:0 cfs.
Adjusted for 15 min:0 cfs.
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 29
LID Report
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 30
Model Default Modifications
Total of 0 changes have been made.
PERLND Changes
No PERLND changes have been made.
IMPLND Changes
No IMPLND changes have been made.
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 31
Appendix
Predeveloped Schematic
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 32
Mitigated Schematic
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 33
Predeveloped UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 Seattle Pipe Trades 2017-02-21.wdm
MESSU 25 PreSeattle Pipe Trades 2017-02-21.MES
27 PreSeattle Pipe Trades 2017-02-21.L61
28 PreSeattle Pipe Trades 2017-02-21.L62
30 POCSeattle Pipe Trades 2017-02-211.dat
31 POCSeattle Pipe Trades 2017-02-212.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
PERLND 7
IMPLND 11
PERLND 3
PERLND 5
COPY 501
COPY 502
DISPLY 1
DISPLY 2
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Disturbed Area MAX 1 2 30 9
2 Basin 2 SOUTH DRAINAGE MAX 1 2 31 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
502 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
7 A/B, Lawn, Flat 1 1 1 1 27 0
3 A/B, Forest, Steep 1 1 1 1 27 0
5 A/B, Pasture, Mod 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 34
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
7 0 0 1 0 0 0 0 0 0 0 0 0
3 0 0 1 0 0 0 0 0 0 0 0 0
5 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
7 0 0 4 0 0 0 0 0 0 0 0 0 1 9
3 0 0 4 0 0 0 0 0 0 0 0 0 1 9
5 0 0 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
7 0 0 0 0 0 0 0 0 0 0 0
3 0 0 0 0 0 0 0 0 0 0 0
5 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
7 0 5 0.8 400 0.05 0.3 0.996
3 0 5 2 400 0.15 0.3 0.996
5 0 5 1.5 400 0.1 0.3 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
7 0 0 2 2 0 0 0
3 0 0 2 2 0 0 0
5 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
7 0.1 0.5 0.25 0 0.7 0.25
3 0.2 0.5 0.35 0 0.7 0.7
5 0.15 0.5 0.3 0 0.7 0.4
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
7 0 0 0 0 3 1 0
3 0 0 0 0 3 1 0
5 0 0 0 0 3 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
11 PARKING/FLAT 1 1 1 27 0
END GEN-INFO
*** Section IWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
11 0 0 1 0 0 0
END ACTIVITY
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 35
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
11 0 0 4 0 0 0 1 9
END PRINT-INFO
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
# - # CSNO RTOP VRS VNN RTLI ***
11 0 0 0 0 0
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
11 400 0.01 0.1 0.1
END IWAT-PARM2
IWAT-PARM3
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
11 0 0
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
11 0 0
END IWAT-STATE1
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
Disturbed Area***
PERLND 7 0.1 COPY 501 12
PERLND 7 0.1 COPY 501 13
IMPLND 11 0.5 COPY 501 15
Basin 2 SOUTH DRAINAGE***
PERLND 3 0.22 COPY 502 12
PERLND 3 0.22 COPY 502 13
PERLND 5 0.45 COPY 502 12
PERLND 5 0.45 COPY 502 13
******Routing******
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
COPY 502 OUTPUT MEAN 1 1 48.4 DISPLY 2 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
in out ***
END GEN-INFO
*** Section RCHRES***
ACTIVITY
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 36
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
END HYDR-PARM2
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
END HYDR-INIT
END RCHRES
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
END FTABLES
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 501 FLOW ENGL REPL
COPY 502 OUTPUT MEAN 1 1 48.4 WDM 502 FLOW ENGL REPL
END EXT TARGETS
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
MASS-LINK 15
IMPLND IWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 15
END MASS-LINK
END RUN
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:38 PM Page 37
Mitigated UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 Seattle Pipe Trades 2017-02-21.wdm
MESSU 25 MitSeattle Pipe Trades 2017-02-21.MES
27 MitSeattle Pipe Trades 2017-02-21.L61
28 MitSeattle Pipe Trades 2017-02-21.L62
30 POCSeattle Pipe Trades 2017-02-211.dat
31 POCSeattle Pipe Trades 2017-02-212.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
IMPLND 1
IMPLND 16
RCHRES 1
PERLND 3
PERLND 5
IMPLND 17
RCHRES 2
COPY 1
COPY 501
COPY 601
COPY 2
COPY 502
COPY 602
DISPLY 1
DISPLY 2
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Permeable Pavement 1 MAX 1 2 30 9
2 Permeable Pavement 2 MAX 1 2 31 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
601 1 1
2 1 1
502 1 1
602 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 38
# - # User t-series Engl Metr ***
in out ***
3 A/B, Forest, Steep 1 1 1 1 27 0
5 A/B, Pasture, Mod 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
3 0 0 1 0 0 0 0 0 0 0 0 0
5 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
3 0 0 4 0 0 0 0 0 0 0 0 0 1 9
5 0 0 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
3 0 0 0 0 0 0 0 0 0 0 0
5 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
3 0 5 2 400 0.15 0.3 0.996
5 0 5 1.5 400 0.1 0.3 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
3 0 0 2 2 0 0 0
5 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
3 0.2 0.5 0.35 0 0.7 0.7
5 0.15 0.5 0.3 0 0.7 0.4
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
3 0 0 0 0 3 1 0
5 0 0 0 0 3 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
1 ROADS/FLAT 1 1 1 27 0
16 Porous Pavement 1 1 1 27 0
17 Porous Pavement 1 1 1 27 0
END GEN-INFO
*** Section IWATER***
ACTIVITY
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 39
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
1 0 0 1 0 0 0
16 0 0 1 0 0 0
17 0 0 1 0 0 0
END ACTIVITY
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
1 0 0 4 0 0 0 1 9
16 0 0 4 0 0 0 1 9
17 0 0 4 0 0 0 1 9
END PRINT-INFO
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
# - # CSNO RTOP VRS VNN RTLI ***
1 0 0 0 0 0
16 0 0 0 0 0
17 0 0 0 0 0
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
1 400 0.01 0.1 0.1
16 400 0.01 0.1 0.1
17 400 0.01 0.1 0.1
END IWAT-PARM2
IWAT-PARM3
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
1 0 0
16 0 0
17 0 0
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
1 0 0
16 0 0
17 0 0
END IWAT-STATE1
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
IMPLND 16 0.573 RCHRES 1 5
IMPLND 17 0.1415 RCHRES 2 5
Basin 1***
IMPLND 1 0.18 COPY 501 15
IMPLND 1 0.18 COPY 601 15
Basin 2 South Drainage***
PERLND 3 0.22 COPY 502 12
PERLND 3 0.22 COPY 602 12
PERLND 3 0.22 COPY 502 13
PERLND 3 0.22 COPY 602 13
PERLND 5 0.18 COPY 502 12
PERLND 5 0.18 COPY 602 12
PERLND 5 0.18 COPY 502 13
PERLND 5 0.18 COPY 602 13
******Routing******
RCHRES 1 1 COPY 501 17
RCHRES 2 1 COPY 502 17
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 40
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
COPY 502 OUTPUT MEAN 1 1 48.4 DISPLY 2 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
in out ***
1 Permeable Paveme-005 2 1 1 1 28 0 1
2 Permeable Paveme-008 2 1 1 1 28 0 1
END GEN-INFO
*** Section RCHRES***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
1 1 0 0 0 0 0 0 0 0 0
2 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
1 4 0 0 0 0 0 0 0 0 0 1 9
2 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
1 0 1 0 0 4 5 0 0 0 0 0 0 0 0 2 2 2 2 2
2 0 1 0 0 4 5 0 0 0 0 0 0 0 0 2 2 2 2 2
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
1 1 0.01 0.0 0.0 0.5 0.0
2 2 0.05 0.0 0.0 0.5 0.0
END HYDR-PARM2
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
1 0 4.0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
2 0 4.0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
END HYDR-INIT
END RCHRES
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
FTABLE 1
90 5
Depth Area Volume Outflow1 Outflow2 Velocity Travel Time***
(ft) (acres) (acre-ft) (cfs) (cfs) (ft/sec) (Minutes)***
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 41
0.000000 0.573003 0.000000 0.000000 0.000000
0.012033 0.573003 0.002069 0.000000 0.173333
0.024067 0.573003 0.004137 0.000000 0.173333
0.036100 0.573003 0.006206 0.000000 0.173333
0.048133 0.573003 0.008274 0.000000 0.173333
0.060167 0.573003 0.010343 0.000000 0.173333
0.072200 0.573003 0.012411 0.000000 0.173333
0.084233 0.573003 0.014480 0.000000 0.173333
0.096267 0.573003 0.016548 0.000000 0.173333
0.108300 0.573003 0.018617 0.000000 0.173333
0.120333 0.573003 0.020685 0.000000 0.173333
0.132367 0.573003 0.022754 0.000000 0.173333
0.144400 0.573003 0.024822 0.000000 0.173333
0.156433 0.573003 0.026891 0.000000 0.173333
0.168467 0.573003 0.028960 0.000000 0.173333
0.180500 0.573003 0.031028 0.000000 0.173333
0.192533 0.573003 0.033097 0.000000 0.173333
0.204567 0.573003 0.035165 0.000000 0.173333
0.216600 0.573003 0.037234 0.000000 0.173333
0.228633 0.573003 0.039302 0.000000 0.173333
0.240667 0.573003 0.041371 0.000000 0.173333
0.252700 0.573003 0.043439 0.000000 0.173333
0.264733 0.573003 0.045508 0.000000 0.173333
0.276767 0.573003 0.047576 0.000000 0.173333
0.288800 0.573003 0.049645 0.000000 0.173333
0.300833 0.573003 0.051713 0.000000 0.173333
0.312867 0.573003 0.053782 0.000000 0.173333
0.324900 0.573003 0.055851 0.000000 0.173333
0.336933 0.573003 0.057919 0.000000 0.173333
0.348967 0.573003 0.059988 0.000000 0.173333
0.361000 0.573003 0.062056 0.000000 0.173333
0.373033 0.573003 0.064125 0.000000 0.173333
0.385067 0.573003 0.066193 0.000000 0.173333
0.397100 0.573003 0.068262 0.000000 0.173333
0.409133 0.573003 0.070330 0.000000 0.173333
0.421167 0.573003 0.072399 0.000000 0.173333
0.433200 0.573003 0.074467 0.000000 0.173333
0.445233 0.573003 0.076536 0.000000 0.173333
0.457267 0.573003 0.078605 0.000000 0.173333
0.469300 0.573003 0.080673 0.000000 0.173333
0.481333 0.573003 0.082742 0.000000 0.173333
0.493367 0.573003 0.084810 0.000000 0.173333
0.505400 0.573003 0.086879 0.000000 0.173333
0.517433 0.573003 0.088947 0.000000 0.173333
0.529467 0.573003 0.091016 0.000000 0.173333
0.541500 0.573003 0.093084 0.000000 0.173333
0.553533 0.573003 0.095153 0.000000 0.173333
0.565567 0.573003 0.097221 0.000000 0.173333
0.577600 0.573003 0.099290 0.000000 0.173333
0.589633 0.573003 0.101358 0.000000 0.173333
0.601667 0.573003 0.103427 0.000000 0.173333
0.613700 0.573003 0.105496 0.000000 0.173333
0.625733 0.573003 0.107564 0.000000 0.173333
0.637767 0.573003 0.109633 0.000000 0.173333
0.649800 0.573003 0.111701 0.000000 0.173333
0.661833 0.573003 0.113770 0.000000 0.173333
0.673867 0.573003 0.251672 0.000000 0.173333
0.685900 0.573003 0.389575 0.000000 0.173333
0.697933 0.573003 0.527478 0.000000 0.173333
0.709967 0.573003 0.665380 0.000000 0.173333
0.722000 0.573003 0.803283 0.000000 0.173333
0.734033 0.573003 0.941186 0.000000 0.173333
0.746067 0.573003 1.079088 0.000000 0.173333
0.758100 0.573003 1.216991 0.000000 0.173333
0.770133 0.573003 1.354894 0.000000 0.173333
0.782167 0.573003 1.492796 0.000000 0.173333
0.794200 0.573003 1.630699 0.000000 0.173333
0.806233 0.573003 1.768602 0.000000 0.173333
0.818267 0.573003 1.906504 0.000000 0.173333
0.830300 0.573003 2.044407 0.000000 0.173333
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 42
0.842333 0.573003 2.182310 0.000000 0.173333
0.854367 0.573003 2.320212 0.000000 0.173333
0.866400 0.573003 2.458115 0.000000 0.173333
0.878433 0.573003 2.596018 0.000000 0.173333
0.890467 0.573003 2.733920 0.000000 0.173333
0.902500 0.573003 2.871823 0.000000 0.173333
0.914533 0.573003 3.009726 0.000000 0.173333
0.926567 0.573003 3.147628 0.000000 0.173333
0.938600 0.573003 3.285531 0.000000 0.173333
0.950633 0.573003 3.423434 0.000000 0.173333
0.962667 0.573003 3.561336 0.000000 0.173333
0.974700 0.573003 3.699239 0.000000 0.173333
0.986733 0.573003 3.837142 0.000000 0.173333
0.998767 0.573003 3.975044 0.000000 0.173333
1.010800 0.573003 4.112947 0.000000 0.173333
1.022833 0.573003 4.250850 0.000000 0.173333
1.034867 0.573003 4.388752 0.000000 0.173333
1.046900 0.573003 4.526655 0.000000 0.173333
1.058933 0.573003 4.664558 0.000000 0.173333
1.070967 0.573003 4.802460 0.000000 0.173333
END FTABLE 1
FTABLE 2
90 5
Depth Area Volume Outflow1 Outflow2 Velocity Travel Time***
(ft) (acres) (acre-ft) (cfs) (cfs) (ft/sec) (Minutes)***
0.000000 0.141506 0.000000 0.000000 0.000000
0.012033 0.141506 0.000511 0.000000 0.042806
0.024067 0.141506 0.001022 0.000000 0.042806
0.036100 0.141506 0.001533 0.000000 0.042806
0.048133 0.141506 0.002043 0.000000 0.042806
0.060167 0.141506 0.002554 0.000000 0.042806
0.072200 0.141506 0.003065 0.000000 0.042806
0.084233 0.141506 0.003576 0.000000 0.042806
0.096267 0.141506 0.004087 0.000000 0.042806
0.108300 0.141506 0.004598 0.000000 0.042806
0.120333 0.141506 0.005108 0.000000 0.042806
0.132367 0.141506 0.005619 0.000000 0.042806
0.144400 0.141506 0.006130 0.000000 0.042806
0.156433 0.141506 0.006641 0.000000 0.042806
0.168467 0.141506 0.007152 0.000000 0.042806
0.180500 0.141506 0.007663 0.000000 0.042806
0.192533 0.141506 0.008173 0.000000 0.042806
0.204567 0.141506 0.008684 0.000000 0.042806
0.216600 0.141506 0.009195 0.000000 0.042806
0.228633 0.141506 0.009706 0.000000 0.042806
0.240667 0.141506 0.010217 0.000000 0.042806
0.252700 0.141506 0.010728 0.000000 0.042806
0.264733 0.141506 0.011238 0.000000 0.042806
0.276767 0.141506 0.011749 0.000000 0.042806
0.288800 0.141506 0.012260 0.000000 0.042806
0.300833 0.141506 0.012771 0.000000 0.042806
0.312867 0.141506 0.013282 0.000000 0.042806
0.324900 0.141506 0.013793 0.000000 0.042806
0.336933 0.141506 0.014303 0.000000 0.042806
0.348967 0.141506 0.014814 0.000000 0.042806
0.361000 0.141506 0.015325 0.000000 0.042806
0.373033 0.141506 0.015836 0.000000 0.042806
0.385067 0.141506 0.016347 0.000000 0.042806
0.397100 0.141506 0.016858 0.000000 0.042806
0.409133 0.141506 0.017368 0.000000 0.042806
0.421167 0.141506 0.017879 0.000000 0.042806
0.433200 0.141506 0.018390 0.000000 0.042806
0.445233 0.141506 0.018901 0.000000 0.042806
0.457267 0.141506 0.019412 0.000000 0.042806
0.469300 0.141506 0.019923 0.000000 0.042806
0.481333 0.141506 0.020433 0.000000 0.042806
0.493367 0.141506 0.020944 0.000000 0.042806
0.505400 0.141506 0.021455 0.000000 0.042806
0.517433 0.141506 0.021966 0.000000 0.042806
0.529467 0.141506 0.022477 0.000000 0.042806
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 43
0.541500 0.141506 0.022988 0.000000 0.042806
0.553533 0.141506 0.023498 0.000000 0.042806
0.565567 0.141506 0.024009 0.000000 0.042806
0.577600 0.141506 0.024520 0.000000 0.042806
0.589633 0.141506 0.025031 0.000000 0.042806
0.601667 0.141506 0.025542 0.000000 0.042806
0.613700 0.141506 0.026053 0.000000 0.042806
0.625733 0.141506 0.026564 0.000000 0.042806
0.637767 0.141506 0.027074 0.000000 0.042806
0.649800 0.141506 0.027585 0.000000 0.042806
0.661833 0.141506 0.028096 0.000000 0.042806
0.673867 0.141506 0.062152 0.000000 0.042806
0.685900 0.141506 0.096208 0.000000 0.042806
0.697933 0.141506 0.130263 0.000000 0.042806
0.709967 0.141506 0.164319 0.000000 0.042806
0.722000 0.141506 0.198375 0.000000 0.042806
0.734033 0.141506 0.232431 0.000000 0.042806
0.746067 0.141506 0.266486 0.000000 0.042806
0.758100 0.141506 0.300542 0.000000 0.042806
0.770133 0.141506 0.334598 0.000000 0.042806
0.782167 0.141506 0.368654 0.000000 0.042806
0.794200 0.141506 0.402709 0.000000 0.042806
0.806233 0.141506 0.436765 0.000000 0.042806
0.818267 0.141506 0.470821 0.000000 0.042806
0.830300 0.141506 0.504877 0.000000 0.042806
0.842333 0.141506 0.555960 0.000000 0.042806
0.854367 0.141506 0.607044 0.000000 0.042806
0.866400 0.141506 0.658128 0.000000 0.042806
0.878433 0.141506 0.709211 0.000000 0.042806
0.890467 0.141506 0.760295 0.000000 0.042806
0.902500 0.141506 0.811379 0.000000 0.042806
0.914533 0.141506 0.862462 0.000000 0.042806
0.926567 0.141506 0.913546 0.000000 0.042806
0.938600 0.141506 0.964630 0.000000 0.042806
0.950633 0.141506 1.015713 0.000000 0.042806
0.962667 0.141506 1.066797 0.000000 0.042806
0.974700 0.141506 1.117881 0.000000 0.042806
0.986733 0.141506 1.168964 0.000000 0.042806
0.998767 0.141506 1.220048 0.000000 0.042806
1.010800 0.141506 1.271132 0.000000 0.042806
1.022833 0.141506 1.322215 0.000000 0.042806
1.034867 0.141506 1.373299 0.000000 0.042806
1.046900 0.141506 1.424383 0.000000 0.042806
1.058933 0.141506 1.475466 0.000000 0.042806
1.070967 0.141506 1.526550 0.000000 0.042806
END FTABLE 2
END FTABLES
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 RCHRES 1 EXTNL POTEV
WDM 1 EVAP ENGL 0.76 RCHRES 2 EXTNL POTEV
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
COPY 1 OUTPUT MEAN 1 1 48.4 WDM 701 FLOW ENGL REPL
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 801 FLOW ENGL REPL
COPY 601 OUTPUT MEAN 1 1 48.4 WDM 901 FLOW ENGL REPL
COPY 2 OUTPUT MEAN 1 1 48.4 WDM 702 FLOW ENGL REPL
COPY 502 OUTPUT MEAN 1 1 48.4 WDM 802 FLOW ENGL REPL
COPY 602 OUTPUT MEAN 1 1 48.4 WDM 902 FLOW ENGL REPL
END EXT TARGETS
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 44
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 5
IMPLND IWATER SURO 0.083333 RCHRES INFLOW IVOL
END MASS-LINK 5
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
MASS-LINK 15
IMPLND IWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 15
MASS-LINK 17
RCHRES OFLOW OVOL 1 COPY INPUT MEAN
END MASS-LINK 17
END MASS-LINK
END RUN
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 45
Predeveloped HSPF Message File
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 46
Mitigated HSPF Message File
Seattle Pipe Trades 2017-02-21 3/21/2017 9:05:39 PM Page 47
Disclaimer
Legal Notice
This program and accompanying documentation are provided 'as-is' without warranty of any kind. The
entire risk regarding the performance and results of this program is assumed by End User. Clear
Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either
expressed or implied, including but not limited to implied warranties of program and accompanying
documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever
(including without limitation to damages for loss of business profits, loss of business information,
business interruption, and the like) arising out of the use of, or inability to use this program even
if Clear Creek Solutions Inc. or their authorized representatives have been advised of the
possibility of such damages. Software Copyright © by : Clear Creek Solutions, Inc. 2005-2017; All
Rights Reserved.
Clear Creek Solutions, Inc.
6200 Capitol Blvd. Ste F
Olympia, WA. 98501
Toll Free 1(866)943-0304
Local (360)943-0304
www.clearcreeksolutions.com
Page 9
5.0 CONVEYANCE SYSTEM ANALYSIS AND DESIGN
Stormwater runoff generated from the parking lot expansion area will be 100 percent
infiltrated through permeable pavement section. No new flow to conveyance systems
or pipes are a part of this proposal.
Existing upstream flow is rerouted around the new building addition and the flow to the moved
CB's now infiltrates through the PAP. Thus the flow in the pipes is reduced but the size remains
the same as the existing.No increase in flow characteristics for the Private Stormwater system.
Existing pipes are 12" diameter.
Page 10
6.0 SPECIAL REPORTS AND STUDIES
Geotechnical Engineering Services, Boeing 25-20 Parking Lot Addition
Boeing Longacres Park, Renton, Washington, prepared by GeoEngineers,
dated November 15, 2013.
Wetland Determination for Boeing Building 25-20 Parking Expansion,
prepared by Ecological Solutions, Inc. , dated September 3, 2013
Geotech Consultants Report JN14436 GES - Seattle Pipe Trades.
Dated December 9, 2014
Wetlands Assessment by J. S. Jones Associates
Date March 25, 2009
and updates by:
Wetland Resources, Inc.
Dated September 8, 2014
Geotech Report by PanGeo for Seattle Pipe Trades
Dated June 26, 2015
Page 11
7.0 OTHER PERMITS
The following permits and/or approvals are thought to be required as part of this project:
· Construction Stormwater General Permit (Department of Ecology) May not be needed
as no discharge from the site due to the permeable pavement. Confirm. City please confirm.
willConstruction Stormwater General Permit (Department of Ecology) may be needed
as the total cleared area is about one acre. Owner and Contractor have applied for
a waiver from DOE. They likely will receive a waiver as the work is planned for the
summer months and the area of clearing in total is just over the limit. Application is
attached below.
· SEPA Environmental Review
· Land Surface Modification (grading) Permit
· Drainage Plan Review
· Clearing and Grading Permit
Page 12
8.0 ESC ANALYSIS AND DESIGN
TESC measures are put into place to prevent sediment from leaving the site. The site is
generally flat. The proposed TESC plan will include, but not be limited to, the following
guidelines set in the 2009 KCWSWDM in order to comply with Core Requirement No. 5.
1. Clearing Limits – Clearing limits specify the boundary of the work to be done.
Clearing are defined on the TESC plans and will be flagged in the field.
2. Cover Measures – Cover measures are involved (typically) with the means to control
erosion of exposed soil and are specified on the TESC plans.
3. Perimeter Protection – Perimeter protection keeps site sediment from leaving the
construction site. This type of protection typically involves a silt fence. The silt fence
and clearing limits are shown on the TESC plans.
4. Traffic Area Stabilization – Traffic area stabilization is addressed by a stabilized
construction entrance.
5. Sediment Retention – Retention will be established by silt fences around the
perimeter and catch basin inserts that will control of the on-site sediment-laden
water.
6. Surface Water Collection – An interceptor ditch with check dams is shown in the
plans and will be implemented in the field if necessary.
7. Dewatering Control – Any water from dewatering shall be filtered or contained so
sediment can filter out prior to discharge downstream.
8. Dust Control – Dust control will be provided by sprinkling.
9. Wet Season Construction – Construction will be conducted according to the City of
Renton standards during the wet season.
10. Construction Within Sensitive Areas and Buffers - Any construction within the
wetland buffer will be subject to sensitive areas restrictions and is contained in the
TESC notes.
11. Maintenance – Maintenance requirements are detailed in the TESC notes within the
engineering plans.
12. Final Stabilization – Upon completion of the project, all disturbed areas will be
stabilized and Best Management Practices removed.
Page 13
9.0 BOND QUANTITIES, FACILITY SUMMARIES, AND DECLARATION OF COVENANT
Planning Division |1055 South Grady Way – 6th Floor | Renton, WA 98057 (425) 430-7200••Section I: Project Information•••Section II: Bond Quantities Worksheets••Section II.a EROSION CONTROL (Stabilization/Erosion Sediment Control (ESC))•Section II.b TRANSPORTATION (Street and Site Improvements)•Section II.c DRAINAGE (Drainage and Stormwater Facilities): •Section II.d WATER - ONLY APPLICABLE IF WATER SERVICE IS PROVIDED BY CITY OF RENTON•Section II.e SANITARY SEWER - ONLY APPLICABLE IF SEWER SERVICE IS PROVIDED BY CITY OF RENTON••••••Section III. Bond Worksheet• This section calculates the required Permit Bond for construction permit issuance as well as the required Maintenance Bond for project close-out submittals to release the permit bond on a project. All unit prices include labor, equipment, materials, overhead and profit. Complete the 'Quantity' columns for each of the appropriate section(s). Include existing Right-of-Way (ROW), Future Public Improvements and Private Improvements.The 'Quantity Remaining' column is only to be used when a project is under construction. The City allows one (1) bond reduction during the life of the project with the exception of the maintenance period reduction.Excel will auto-calculate and auto-populate the relevant fields and subtotals throughout the document. Only the 'Quantity' columns should need completing.Additional items not included in the lists can be added under the "write-in" sections. Provide a complete description, cost estimate and unit of measure for each write-in item. Note: Private improvements, with the exception of stormwater facilities, are not included in the bond amount calculation, but must be entered on the form. Stormwater facilities (public and private) are required to be included in the bond amount.BOND QUANTITY WORKSHEET INSTRUCTIONSThis worksheet is intended to be a "working" copy of the bond quantity worksheet, which will be used throughout all phases of the project, from initial submittal to project close-out approval. Submit this workbook, in its entirety, as follows:The following forms are to be completed by the engineer/developer/applicant as applicable to the project: The Bond Worksheet form will auto-calculate and auto-populate from the information provided in Section I and Section II.This section includes all pertinent information for the projectSection II contains a separate spreadsheet TAB for each of the following specialties: (1) electronic copy (.xlsx format) and (1) hard copy of the entire workbook for civil construction permit submittal. Hard copies are to be included as part of the Technical Information Report (TIR).(1) electronic copy (.xlsx format) and (1) hard copy of the entire workbook for final close-out submittal.This section must be completed in its entiretyInformation from this section auto-populates to all other relevant areas of the workbookPage 1 of 14Ref 8-H Bond Quantity WorksheetINSTRUCTIONSUnit Prices Updated: 03/2016Version: 06/2016Printed 5/5/2017
Planning Division |1055 South Grady Way – 6th Floor | Renton, WA 98057 (425) 430-7200Date Prepared: Name:PE Registration No:Firm Name:Firm Address:Phone No.Email Address:Project Name: Project Owner:CED Plan # (LUA):Phone:CED Permit # (U):Address: Site Address:Street Intersection:Addt'l Project Owner:Parcel #(s):Phone:Address: Clearing and grading greater than or equal to 5,000 board feet of timber? Yes/No:NOWater Service Provided by:If Yes, Provide Forest Practice Permit #:Sewer Service Provided by: SITE IMPROVEMENT BOND QUANTITY WORKSHEETPROJECT INFORMATIONCITY OF RENTONCITY OF RENTON1 Select the current project status/phase from the following options: For Approval - Preliminary Data Enclosed, pending approval from the City; For Construction - Estimated Data Enclosed, Plans have been approved for contruction by the City; Project Closeout - Final Costs and Quantities Enclosed for Project Close-out SubmittalPhoneEngineer Stamp Required (all cost estimates must have original wet stamp and signature)Clearing and GradingUtility ProvidersN/AProject Location and DescriptionProject Owner InformationSeattle Pipe TradesRenton, WA 242304-9122 and 3Seattle Pipe Trades##-######425-277-6680 1/6/2017Prepared by:FOR APPROVALProject Phase 1dons@novadyne.usDonald K Scarberry, P.E.18347Novadyne Civil Engineers414 N Bridgeton Rd425-753-1869595 MONSTER RD SW Renton WA595 Monster Rd SWAdditional Project OwnerMonster RoadU15005192AddressAbbreviated Legal Description:Abbreviated Legal Description: A PORTION OF THE NW 14 OF THE NW 14, SEC. 24, T 23N, R 4E, W.M.City, State, ZipPage 2 of 14Ref 8-H Bond Quantity WorksheetSECTION I PROJECT INFORMATIONUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192UnitReference #PriceUnitQuantity CostBackfill & compaction-embankmentESC-16.50$ CY Check dams, 4" minus rockESC-2SWDM 5.4.6.380.00$ Each Catch Basin ProtectionESC-335.50$ Each5177.50Crushed surfacing 1 1/4" minusESC-4WSDOT 9-03.9(3)95.00$ CY DitchingESC-59.00$ CY100900.00Excavation-bulkESC-62.00$ CY100200.00Fence, siltESC-7SWDM 5.4.3.11.50$ LF590885.00Fence, Temporary (NGPE)ESC-81.50$ LF340510.00Geotextile FabricESC-92.50$ SY Hay Bale Silt TrapESC-100.50$ Each2010.00HydroseedingESC-11SWDM 5.4.2.40.80$ SY33332,666.40Interceptor Swale / DikeESC-121.00$ LF100100.00Jute MeshESC-13SWDM 5.4.2.23.50$ SY Level SpreaderESC-141.75$ LF2543.75Mulch, by hand, straw, 3" deepESC-15SWDM 5.4.2.12.50$ SY Mulch, by machine, straw, 2" deepESC-16SWDM 5.4.2.12.00$ SY33336,666.00Piping, temporary, CPP, 6"ESC-1712.00$ LF Piping, temporary, CPP, 8"ESC-1814.00$ LF Piping, temporary, CPP, 12"ESC-1918.00$ LF1001,800.00Plastic covering, 6mm thick, sandbaggedESC-20SWDM 5.4.2.34.00$ SY Rip Rap, machine placed; slopesESC-21WSDOT 9-13.1(2)45.00$ CY Rock Construction Entrance, 50'x15'x1'ESC-22SWDM 5.4.4.11,800.00$ Each Rock Construction Entrance, 100'x15'x1'ESC-23SWDM 5.4.4.13,200.00$ Each13,200.00Sediment pond riser assemblyESC-24SWDM 5.4.5.22,200.00$ Each Sediment trap, 5' high berm ESC-25SWDM 5.4.5.119.00$ LF Sed. trap, 5' high, riprapped spillway berm section ESC-26SWDM 5.4.5.170.00$ LF Seeding, by handESC-27SWDM 5.4.2.41.00$ SY Sodding, 1" deep, level groundESC-28SWDM 5.4.2.58.00$ SY Sodding, 1" deep, sloped groundESC-29SWDM 5.4.2.510.00$ SY TESC SupervisorESC-30110.00$ HR Water truck, dust controlESC-31SWDM 5.4.7140.00$ HR UnitReference #PriceUnitQuantity Cost EROSION/SEDIMENT SUBTOTAL:17,158.65SALES TAX @ 9.5%1,630.07EROSION/SEDIMENT TOTAL:18,788.72(A)SITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR EROSION & SEDIMENT CONTROLDescription No.(A)WRITE-IN-ITEMS Page 3 of 14Ref 8-H Bond Quantity WorksheetSECTION II.a EROSION_CONTROLUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostGENERAL ITEMS Backfill & Compaction- embankmentGI-16.00$ CYBackfill & Compaction- trenchGI-29.00$ CYClear/Remove Brush, by hand (SY)GI-31.00$ SYBollards - fixedGI-4240.74$ EachBollards - removableGI-5452.34$ EachClearing/Grubbing/Tree RemovalGI-610,000.00$ Acre0.52065,205.69Excavation - bulkGI-72.00$ CY16723,344.00Excavation - TrenchGI-85.00$ CYFencing, cedar, 6' highGI-920.00$ LFFencing, chain link, 4'GI-1038.31$ LFFencing, chain link, vinyl coated, 6' highGI-1120.00$ LFFencing, chain link, gate, vinyl coated, 20' GI-121,400.00$ EachFill & compact - common barrowGI-1325.00$ CY55413,850.00Fill & compact - gravel baseGI-1427.00$ CYFill & compact - screened topsoilGI-1539.00$ CYGabion, 12" deep, stone filled mesh GI-1665.00$ SYGabion, 18" deep, stone filled mesh GI-1790.00$ SYGabion, 36" deep, stone filled meshGI-18150.00$ SYGrading, fine, by handGI-192.50$ SYGrading, fine, with graderGI-202.00$ SY2777.85,555.56Monuments, 3' LongGI-21250.00$ EachSensitive Areas SignGI-227.00$ Each1070.00Sodding, 1" deep, sloped groundGI-238.00$ SYSurveying, line & gradeGI-24850.00$ DaySurveying, lot location/linesGI-251,800.00$ AcreTopsoil Type A (imported)GI-2628.50$ CYTraffic control crew ( 2 flaggers )GI-27120.00$ HRTrail, 4" chipped woodGI-288.00$ SYTrail, 4" crushed cinderGI-299.00$ SYTrail, 4" top courseGI-3012.00$ SYConduit, 2"GI-315.00$ LFWall, retaining, concreteGI-3255.00$ SFWall, rockeryGI-3315.00$ SFSUBTOTAL THIS PAGE:28,025.25(B)(C)(D)(E)SITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR STREET AND SITE IMPROVEMENTSQuantity Remaining (Bond Reduction) (B)(C)Page 4 of 14Ref 8-H Bond Quantity WorksheetSECTION II.b TRANSPORTATIONUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostSITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR STREET AND SITE IMPROVEMENTSQuantity Remaining (Bond Reduction) (B)(C)ROAD IMPROVEMENT/PAVEMENT/SURFACINGAC Grinding, 4' wide machine < 1000syRI-130.00$ SYAC Grinding, 4' wide machine 1000-2000syRI-216.00$ SYAC Grinding, 4' wide machine > 2000syRI-310.00$ SYAC Removal/DisposalRI-435.00$ SY165057,750.00Barricade, Type III ( Permanent )RI-556.00$ LFGuard RailRI-630.00$ LFCurb & Gutter, rolledRI-717.00$ LFCurb & Gutter, verticalRI-812.50$ LF94011,750.00Curb and Gutter, demolition and disposalRI-918.00$ LFCurb, extruded asphaltRI-105.50$ LFCurb, extruded concreteRI-117.00$ LFSawcut, asphalt, 3" depthRI-121.85$ LF100185.00Sawcut, concrete, per 1" depthRI-133.00$ LFSealant, asphaltRI-142.00$ LF100200.00Shoulder, gravel, 4" thickRI-1515.00$ SYSidewalk, 4" thickRI-1638.00$ SYSidewalk, 4" thick, demolition and disposalRI-1732.00$ SYSidewalk, 5" thickRI-1841.00$ SY277.7811,388.89Sidewalk, 5" thick, demolition and disposalRI-1940.00$ SYSign, Handicap RI-2085.00$ Each4340.00Striping, per stallRI-217.00$ Each64448.00Striping, thermoplastic, ( for crosswalk )RI-223.00$ SFStriping, 4" reflectorized lineRI-230.50$ LFAdditional 2.5" Crushed SurfacingRI-243.60$ SYHMA 1/2" Overlay 1.5" RI-2514.00$ SYHMA 1/2" Overlay 2"RI-2618.00$ SYHMA Road, 2", 4" rock, First 2500 SYRI-2728.00$ SYHMA Road, 2", 4" rock, Qty. over 2500SYRI-2821.00$ SYHMA Road, 4", 6" rock, First 2500 SYRI-2945.00$ SYHMA Road, 4", 6" rock, Qty. over 2500 SYRI-3037.00$ SYHMA Road, 4", 4.5" ATBRI-3138.00$ SYGravel Road, 4" rock, First 2500 SYRI-3215.00$ SYGravel Road, 4" rock, Qty. over 2500 SYRI-3310.00$ SYThickened EdgeRI-348.60$ LFSUBTOTAL THIS PAGE:82,061.89(B)(C)(D)(E)Page 5 of 14Ref 8-H Bond Quantity WorksheetSECTION II.b TRANSPORTATIONUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostSITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR STREET AND SITE IMPROVEMENTSQuantity Remaining (Bond Reduction) (B)(C)PARKING LOT SURFACINGNo.2" AC, 2" top course rock & 4" borrowPL-121.00$ SY2" AC, 1.5" top course & 2.5" base coursePL-228.00$ SY274476,832.004" select borrowPL-35.00$ SY274413,720.001.5" top course rock & 2.5" base coursePL-414.00$ SYSUBTOTAL PARKING LOT SURFACING:90,552.00(B)(C)(D)(E)LANDSCAPING & VEGETATIONNo.Street TreesLA-1Median LandscapingLA-2Right-of-Way LandscapingLA-3Wetland LandscapingLA-4SUBTOTAL LANDSCAPING & VEGETATION:(B)(C)(D)(E)TRAFFIC & LIGHTINGNo.SignsTR-1Street Light System ( # of Poles)TR-2Traffic SignalTR-3Traffic Signal ModificationTR-4SUBTOTAL TRAFFIC & LIGHTING:(B)(C)(D)(E)WRITE-IN-ITEMSSUBTOTAL WRITE-IN ITEMS:STREET AND SITE IMPROVEMENTS SUBTOTAL:110,087.14SALES TAX @ 9.5%10,458.28STREET AND SITE IMPROVEMENTS TOTAL:120,545.42(B)(C)(D)(E)Page 6 of 14Ref 8-H Bond Quantity WorksheetSECTION II.b TRANSPORTATIONUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostDRAINAGE (CPE = Corrugated Polyethylene Pipe, N12 or Equivalent) For Culvert prices, Average of 4' cover was assumed. Assume perforated PVC is same price as solid pipe.) Access Road, R/DD-126.00$ SY* (CBs include frame and lid)BeehiveD-290.00$ EachThrough-curb Inlet FrameworkD-3400.00$ EachCB Type ID-41,500.00$ EachCB Type ILD-51,750.00$ Each11,750.00CB Type II, 48" diameterD-62,300.00$ Each12,300.00 for additional depth over 4' D-7480.00$ FT1480.00CB Type II, 54" diameterD-82,500.00$ Each for additional depth over 4'D-9495.00$ FTCB Type II, 60" diameterD-102,800.00$ Each for additional depth over 4'D-11600.00$ FTCB Type II, 72" diameterD-126,000.00$ Each for additional depth over 4'D-13850.00$ FTCB Type II, 96" diameterD-1414,000.00$ Each for additional depth over 4'D-15925.00$ FTTrash Rack, 12"D-16350.00$ EachTrash Rack, 15"D-17410.00$ EachTrash Rack, 18"D-18480.00$ EachTrash Rack, 21"D-19550.00$ EachCleanout, PVC, 4"D-20150.00$ EachCleanout, PVC, 6"D-21170.00$ EachCleanout, PVC, 8"D-22200.00$ EachCulvert, PVC, 4" (Not allowed in ROW)D-2310.00$ LFCulvert, PVC, 6" (Not allowed in ROW)D-2413.00$ LFCulvert, PVC, 8" (Not allowed in ROW)D-2515.00$ LFCulvert, PVC, 12" (Not allowed in ROW)D-2623.00$ LFCulvert, PVC, 15" (Not allowed in ROW)D-2735.00$ LFCulvert, PVC, 18" (Not allowed in ROW)D-2841.00$ LFCulvert, PVC, 24" (Not allowed in ROW)D-2956.00$ LFCulvert, PVC, 30" (Not allowed in ROW)D-3078.00$ LFCulvert, PVC, 36" (Not allowed in ROW)D-31130.00$ LFCulvert, CMP, 8"D-3219.00$ LFCulvert, CMP, 12"D-3329.00$ LFSUBTOTAL THIS PAGE:4,530.00(B)(C)(D)(E)SITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR DRAINAGE AND STORMWATER FACILITIESQuantity Remaining (Bond Reduction) (B)(C)Page 7 of 14Ref 8-H Bond Quantity WorksheetSECTION II.c DRAINAGEUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostSITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR DRAINAGE AND STORMWATER FACILITIESQuantity Remaining (Bond Reduction) (B)(C)DRAINAGE (Continued)Culvert, CMP, 15"D-3435.00$ LFCulvert, CMP, 18"D-3541.00$ LFCulvert, CMP, 24"D-3656.00$ LFCulvert, CMP, 30"D-3778.00$ LFCulvert, CMP, 36"D-38130.00$ LFCulvert, CMP, 48"D-39190.00$ LFCulvert, CMP, 60"D-40270.00$ LFCulvert, CMP, 72"D-41350.00$ LFCulvert, Concrete, 8"D-4242.00$ LFCulvert, Concrete, 12"D-4348.00$ LFCulvert, Concrete, 15"D-4478.00$ LFCulvert, Concrete, 18"D-4548.00$ LFCulvert, Concrete, 24"D-4678.00$ LFCulvert, Concrete, 30"D-47125.00$ LFCulvert, Concrete, 36"D-48150.00$ LFCulvert, Concrete, 42"D-49175.00$ LFCulvert, Concrete, 48"D-50205.00$ LFCulvert, CPE, 6" (Not allowed in ROW)D-5114.00$ LFCulvert, CPE, 8" (Not allowed in ROW)D-5216.00$ LFCulvert, CPE, 12" (Not allowed in ROW)D-5324.00$ LFCulvert, CPE, 15" (Not allowed in ROW)D-5435.00$ LFCulvert, CPE, 18" (Not allowed in ROW)D-5541.00$ LFCulvert, CPE, 24" (Not allowed in ROW)D-5656.00$ LFCulvert, CPE, 30" (Not allowed in ROW)D-5778.00$ LFCulvert, CPE, 36" (Not allowed in ROW)D-58130.00$ LFCulvert, LCPE, 6"D-5960.00$ LFCulvert, LCPE, 8"D-6072.00$ LFCulvert, LCPE, 12"D-6184.00$ LFCulvert, LCPE, 15"D-6296.00$ LFCulvert, LCPE, 18"D-63108.00$ LFCulvert, LCPE, 24"D-64120.00$ LFCulvert, LCPE, 30"D-65132.00$ LFCulvert, LCPE, 36"D-66144.00$ LFCulvert, LCPE, 48"D-67156.00$ LFCulvert, LCPE, 54"D-68168.00$ LFSUBTOTAL THIS PAGE:(B)(C)(D)(E)Page 8 of 14Ref 8-H Bond Quantity WorksheetSECTION II.c DRAINAGEUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostSITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR DRAINAGE AND STORMWATER FACILITIESQuantity Remaining (Bond Reduction) (B)(C)DRAINAGE (Continued)Culvert, LCPE, 60"D-69180.00$ LFCulvert, LCPE, 72"D-70192.00$ LFCulvert, HDPE, 6"D-7142.00$ LFCulvert, HDPE, 8"D-7242.00$ LFCulvert, HDPE, 12"D-7374.00$ LF20515,170.00Culvert, HDPE, 15"D-74106.00$ LFCulvert, HDPE, 18"D-75138.00$ LFCulvert, HDPE, 24"D-76221.00$ LFCulvert, HDPE, 30"D-77276.00$ LFCulvert, HDPE, 36"D-78331.00$ LFCulvert, HDPE, 48"D-79386.00$ LFCulvert, HDPE, 54"D-80441.00$ LFCulvert, HDPE, 60"D-81496.00$ LFCulvert, HDPE, 72"D-82551.00$ LFPipe, Polypropylene, 6"D-8384.00$ LFPipe, Polypropylene, 8"D-8489.00$ LFPipe, Polypropylene, 12"D-8595.00$ LFPipe, Polypropylene, 15"D-86100.00$ LFPipe, Polypropylene, 18"D-87106.00$ LFPipe, Polypropylene, 24"D-88111.00$ LFPipe, Polypropylene, 30"D-89119.00$ LFPipe, Polypropylene, 36"D-90154.00$ LFPipe, Polypropylene, 48"D-91226.00$ LFPipe, Polypropylene, 54"D-92332.00$ LFPipe, Polypropylene, 60"D-93439.00$ LFPipe, Polypropylene, 72"D-94545.00$ LFCulvert, DI, 6"D-9561.00$ LFCulvert, DI, 8"D-9684.00$ LFCulvert, DI, 12"D-97106.00$ LFCulvert, DI, 15"D-98129.00$ LFCulvert, DI, 18"D-99152.00$ LFCulvert, DI, 24"D-100175.00$ LFCulvert, DI, 30"D-101198.00$ LFCulvert, DI, 36"D-102220.00$ LFCulvert, DI, 48"D-103243.00$ LFCulvert, DI, 54"D-104266.00$ LFCulvert, DI, 60"D-105289.00$ LFCulvert, DI, 72"D-106311.00$ LFSUBTOTAL THIS PAGE:15,170.00(B)(C)(D)(E)Page 9 of 14Ref 8-H Bond Quantity WorksheetSECTION II.c DRAINAGEUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostSITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR DRAINAGE AND STORMWATER FACILITIESQuantity Remaining (Bond Reduction) (B)(C)Specialty Drainage ItemsDitching SD-19.50$ CYFlow Dispersal Trench (1,436 base+)SD-328.00$ LF French Drain (3' depth)SD-426.00$ LFGeotextile, laid in trench, polypropyleneSD-53.00$ SYMid-tank Access Riser, 48" dia, 6' deepSD-62,000.00$ EachPond Overflow SpillwaySD-716.00$ SYRestrictor/Oil Separator, 12"SD-81,150.00$ EachRestrictor/Oil Separator, 15"SD-91,350.00$ EachRestrictor/Oil Separator, 18"SD-101,700.00$ EachRiprap, placedSD-1142.00$ CYTank End Reducer (36" diameter)SD-121,200.00$ EachInfiltration pond testingSD-13125.00$ HRPermeable PavementSD-141.00$ SF2469624,696.00Permeable Concrete SidewalkSD-15Culvert, Box __ ft x __ ftSD-16SUBTOTAL SPECIALTY DRAINAGE ITEMS:24,696.00(B)(C)(D)(E)STORMWATER FACILITIES (Include Flow Control and Water Quality Facility Summary Sheet and Sketch)Detention PondSF-1Each Detention TankSF-2Each Detention VaultSF-3Each Infiltration PondSF-4Each Infiltration TankSF-5Each Infiltration VaultSF-6Each Infiltration TrenchesSF-7Each Basic Biofiltration SwaleSF-8Each Wet Biofiltration SwaleSF-9Each WetpondSF-10Each WetvaultSF-11Each Sand FilterSF-12Each Sand Filter VaultSF-13Each Linear Sand FilterSF-14Each StormFilterSF-15Each Rain GardenSF-16Each SUBTOTAL STORMWATER FACILITIES:(B)(C)(D)(E)Page 10 of 14Ref 8-H Bond Quantity WorksheetSECTION II.c DRAINAGEUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostSITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR DRAINAGE AND STORMWATER FACILITIESQuantity Remaining (Bond Reduction) (B)(C)WRITE-IN-ITEMSWI-1WI-2WI-3WI-4WI-5WI-6WI-7WI-8WI-9WI-10WI-11WI-12WI-13WI-14WI-15SUBTOTAL WRITE-IN ITEMS:DRAINAGE AND STORMWATER FACILITIES SUBTOTAL:29,226.00SALES TAX @ 9.5%2,776.47DRAINAGE AND STORMWATER FACILITIES TOTAL:32,002.47(B) (C) (D) (E)Page 11 of 14Ref 8-H Bond Quantity WorksheetSECTION II.c DRAINAGEUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostConnection to Existing WatermainW-12,000.00$ Each24,000.00Ductile Iron Watermain, CL 52, 4 Inch DiameterW-250.00$ LFDuctile Iron Watermain, CL 52, 6 Inch DiameterW-356.00$ LFDuctile Iron Watermain, CL 52, 8 Inch DiameterW-460.00$ LFDuctile Iron Watermain, CL 52, 10 Inch DiameterW-570.00$ LF24216,940.00Ductile Iron Watermain, CL 52, 12 Inch DiameterW-680.00$ LFGate Valve, 4 inch DiameterW-7500.00$ EachGate Valve, 6 inch DiameterW-8700.00$ EachGate Valve, 8 Inch DiameterW-9800.00$ EachGate Valve, 10 Inch DiameterW-101,000.00$ EachGate Valve, 12 Inch DiameterW-111,200.00$ EachFire Hydrant AssemblyW-124,000.00$ Each14,000.00Permanent Blow-Off AssemblyW-131,800.00$ EachAir-Vac Assembly, 2-Inch DiameterW-142,000.00$ EachAir-Vac Assembly, 1-Inch DiameterW-151,500.00$ EachCompound Meter Assembly 3-inch DiameterW-168,000.00$ EachCompound Meter Assembly 4-inch DiameterW-179,000.00$ Each19,000.00Compound Meter Assembly 6-inch DiameterW-1810,000.00$ EachPressure Reducing Valve Station 8-inch to 10-inchW-1920,000.00$ EachWATER SUBTOTAL:33,940.00SALES TAX @ 9.5%3,224.30WATER TOTAL:37,164.30(B) (C) (D) (E)SITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR WATERQuantity Remaining (Bond Reduction) (B)(C)Page 12 of 14Ref 8-H Bond Quantity WorksheetSECTION II.d WATERUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
CED Permit #:U15005192ExistingFuture PublicPrivateRight-of-WayImprovementsImprovements(D) (E)DescriptionNo. Unit PriceUnitQuant.CostQuant.CostQuant.CostQuant.CostClean OutsSS-11,000.00$ Each11,000.00Grease Interceptor, 500 gallonSS-28,000.00$ EachGrease Interceptor, 1000 gallonSS-310,000.00$ EachGrease Interceptor, 1500 gallonSS-415,000.00$ EachSide Sewer Pipe, PVC. 4 Inch DiameterSS-580.00$ LFSide Sewer Pipe, PVC. 6 Inch DiameterSS-695.00$ LF807,600.00Sewer Pipe, PVC, 8 inch DiameterSS-7105.00$ LFSewer Pipe, PVC, 12 Inch DiameterSS-8120.00$ LFSewer Pipe, DI, 8 inch DiameterSS-9115.00$ LFSewer Pipe, DI, 12 Inch DiameterSS-10130.00$ LFManhole, 48 Inch DiameterSS-116,000.00$ EachManhole, 54 Inch DiameterSS-136,500.00$ EachManhole, 60 Inch DiameterSS-157,500.00$ EachManhole, 72 Inch DiameterSS-178,500.00$ EachManhole, 96 Inch DiameterSS-1914,000.00$ EachPipe, C-900, 12 Inch DiameterSS-21180.00$ LFOutside DropSS-241,500.00$ LSInside DropSS-251,000.00$ LSSewer Pipe, PVC, ____ Inch DiameterSS-26Lift Station (Entire System)SS-27LSSANITARY SEWER SUBTOTAL:8,600.00SALES TAX @ 9.5%817.00SANITARY SEWER TOTAL:9,417.00(B) (C) (D) (E)SITE IMPROVEMENT BOND QUANTITY WORKSHEETFOR SANITARY SEWERQuantity Remaining (Bond Reduction) (B)(C)Page 13 of 14Ref 8-H Bond Quantity WorksheetSECTION II.e SANITARY SEWERUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
Planning Division |1055 South Grady Way – 6th Floor | Renton, WA 98057 (425) 430-7200Date:Name:Project Name: PE Registration No:CED Plan # (LUA):Firm Name:CED Permit # (U):Firm Address:Site Address:Phone No.Parcel #(s):Email Address:Project Phase: Site Restoration/Erosion Sediment Control Subtotal (a)(a)18,788.72$ Existing Right-of-Way Improvements Subtotal (b)(b)-$ Future Public Improvements Subtotal(c)(c)-$ Stormwater & Drainage Facilities Subtotal (d)(d)32,002.47$ Bond Reduction (Quantity Remaining)2(e)(e)-$ Site RestorationCivil Construction PermitMaintenance Bond6,400.49$ Bond Reduction2Construction Permit Bond Amount 3Minimum Bond Amount is $10,000.001 Estimate Only - May involve multiple and variable components, which will be established on an individual basis by Development Engineering.2 The City of Renton allows one request only for bond reduction prior to the maintenance period. Reduction of not more than 70% of the original bond amount, provided that the remaining 30% willcover all remaining items to be constructed. 3 Required Bond Amounts are subject to review and modification by Development Engineering.* Note: The word BOND as used in this document means any financial guarantee acceptable to the City of Renton.** Note: All prices include labor, equipment, materials, overhead and profit. T(P +R - S)Prepared by:Project InformationCONSTRUCTION BOND AMOUNT */**(prior to permit issuance)425-753-1869dons@novadyne.usSeattle Pipe Trades##-######595 MONSTER RD SW Renton WA242304-9122 and 3FOR APPROVALU15005192414 N Bridgeton Rd76,186.79$ P (a) x 150%SITE IMPROVEMENT BOND QUANTITY WORKSHEET BOND CALCULATIONS1/6/2017Donald K Scarberry, P.E.18347Novadyne Civil EngineersR((b)+(c)+(d)) x 150%EST1((b) + (c) + (d)) x 20%-$ MAINTENANCE BOND */**(after final acceptance of construction)18,788.72$ -$ 48,003.71$ 28,183.08$ -$ -$ 32,002.47$ S(e) x 150%Page 14 of 14Ref 8-H Bond Quantity WorksheetSECTION III. BOND WORKSHEETUnit Prices Updated: 06/14/2016Version: 06/14/2016Printed 5/5/2017
Page 14
10.0 OPERATIONS AND MAINTENANCE MANUAL
The drainage facilities on this project will be private facilities owned and maintained by
the owner.
Maintenance of the onsite drainage facilities are limited to maintaining the permeable
pavement parking lot and the adjacent ditch, conveyance pipe and pipe inlet trash rack.
Existing Pipe and Conveyance Systems
Please see the following Maintenance requirements No. 6 – Conveyance Pipes and
Ditches and No. 7 – Debris Barriers (i.e. Trash Racks).
Permeable Pavement
The primary goal of porous pavement maintenance is to prevent the pavement surface
and/or the underlying infiltration bed from being clogged with fine sediments. To keep
the system clean throughout the year and prolong its lifespan, the pavement surface
should be vacuumed biannually with a commercial cleaning unit. All inlet structures
within or draining to the infiltration beds should also be cleaned out on a biannual basis.
Planted areas adjacent to porous pavement should be well maintained to prevent soil
washout onto the pavement. If any washout does occur it should be cleaned off the
pavement immediately to prevent further clogging of the pores. Furthermore, if any bare
spots or eroded areas are observed within the planted areas, they should be replanted
and/or stabilized at once. Planted areas should be inspected on a semi-annual basis.
All trash and other litter that is observed during these inspections should be removed.
Superficial dirt does not necessarily clog the pavement voids. However, dirt that is
ground in repeatedly by tires can lead to clogging. Therefore, trucks or other heavy
vehicles should be prevented from tracking or spilling dirt onto the pavement.
Furthermore, all construction or hazardous materials carriers should be prohibited from
entering a porous pavement lot.
Winter Maintenance
Winter maintenance for a porous parking lot may be necessary, but is usually less
intensive than that required for a standard asphalt lot. By its very nature, a porous
pavement system with subsurface aggregate bed has superior snow melting
characteristics than does standard pavement. Therefore, ice and light snow
accumulation are generally not as problematic. However, snow will accumulate during
heavier storms. Abrasives such as sand or cinders should not be applied on or adjacent
to the porous pavement. Snow plowing is necessary for significant snow accumulation,
but should be done carefully (i.e. by setting the blade slightly higher than usual, about an
inch). Standard road salt is acceptable for use as a deicer on porous pavement,
although a non-toxic, organic deicer, applied either as a blended, magnesium chloride-
based liquid product or as pretreated rock salt, is recommended. Please consult local
governmental agency for an acceptable deicer.
RECORDING REQUESTED BY AND
WHEN RECORDED MAIL TO:
CITY CLERK’S OFFICE
CITY OF RENTON
1055 SOUTH GRADY WAY
RENTON, WA 98057
DECLARATION OF COVENANT
FOR MAINTENANCE AND INSPECTION OF FLOW CONTROL BMPS
Grantor:
Grantee: City of Renton
Legal Description:
Additional Legal(s) on:
Assessor's Tax Parcel ID#:
IN CONSIDERATION of the approved City of Renton(check one of the following) residential
building permit, commercial building permit, clearing and grading permit, subdivision permit, or
short subdivision permit for Application File No. LUA/SWP ____________________ relating to the
real property ("Property") described above, the Grantor(s), the owner(s) in fee of that Property, hereby
Seattle Area Plumbing and Pipefitting Industry Journeyman & Apprenticeship Training Trust
242304-9122
X
PARCEL Y, CITY OF RENTON BOUNDARY LINE ADJUSTMENT NO. LUA16-000265,
RECORDED SEPTEMBER 1, 2016 UNDER KING COUNTY RECORDING NO.
20160901900006, RECORDS OF KING COUNTY, WASHINGTON.
covenants(covenant) with City or Renton, a political subdivision of the state of Washington, that
he/she(they) will observe, consent to, and abide by the conditions and obligations set forth and described
in Paragraphs 1 through 8 below with regard to the Property. Grantor(s) hereby grants(grant),
covenants(covenant), and agrees(agree) as follows:
1. Grantor(s) or his/her(their) successors in interest and assigns ("Owners") shall retain, uphold,
and protect the stormwater management devices, features, pathways, limits, and restrictions, known as
flow control best management practices ("BMPs"), shown on the approved Flow Control BMP Site Plan
for the Property attached hereto and incorporated herein as Exhibit A.
2. The Owners shall at their own cost, operate, maintain, and keep in good repair, the Property's
BMPs as described in the approved Design and Maintenance Details for each BMP attached hereto and
incorporated herein as Exhibit B.
3. City or Renton shall provide at least 30 days written notice to the Owners that entry on the
Property is planned for the inspection of the BMPs. After the 30 days, the Owners shall allow the City of
Renton to enter for the sole purpose of inspecting the BMPs. In lieu of inspection by the City, the
Owners may elect to engage a licensed civil engineer registered in the state of Washington who has
expertise in drainage to inspect the BMPs and provide a written report describing their condition. If the
engineer option is chosen, the Owners shall provide written notice to the City of Renton within fifteen
days of receiving the City's notice of inspection. Within 30 days of giving this notice, the Owners, or the
engineer on behalf of the Owners, shall provide the engineer's report to the City of Renton. If the report
is not provided in a timely manner as specified above, the City of Renton may inspect the BMPs without
further notice.
4. If the City determines from its inspection, or from an engineer's report provided in accordance
with Paragraph 3, that maintenance, repair, restoration, and/or mitigation work is required for the BMPs,
The City shall notify the Owners of the specific maintenance, repair, restoration, and/or mitigation work
(Work) required under RMC 4-6-030. The City shall also set a reasonable deadline for completing the
Work or providing an engineer's report that verifies completion of the Work. After the deadline has
passed, the Owners shall allow the City access to re-inspect the BMPs unless an engineer's report has
been provided verifying completion of the Work. If the work is not completed properly within the time
frame set by the City, the City may initiate an enforcement action. Failure to properly maintain the BMPs
is a violation of RMC 4-6-030 and may subject the Owners to enforcement under the RMC 1-3, including
fines and penalties.
5. Apart from performing routine landscape maintenance, the Owners are hereby required to
obtain written approval from the City or Renton before performing any alterations or modifications to the
BMPs.
6. Any notice or approval required to be given by one party to the other under the provisions of
this Declaration of Covenant shall be effective upon personal delivery to the other party, or after three (3)
days from the date that the notice or approval is mailed with delivery confirmation to the current address
on record with each Party. The parties shall notify each other of any change to their addresses.
7. This Declaration of Covenant is intended to promote the efficient and effective management of
surface water drainage on the Property, and it shall inure to the benefit of all the citizens of the City of
Renton and its successors and assigns. This Declaration of Covenant shall run with the land and be
binding upon Grantor(s), and Grantor's(s') successors in interest and assigns.
8. This Declaration of Covenant may be terminated by execution of a written agreement by the
Owners and the City of Renton that is recorded by King County in its real property records.
IN WITNESS WHEREOF, this Declaration of Covenant for the Maintenance and Inspection of
Flow Control BMPs is executed this _____ day of ____________________, 20_____.
GRANTOR, owner of the Property
GRANTOR, owner of the Property
STATE OF WASHINGTON ) COUNTY OF KING )ss.
On this day personally appeared before me:
, to me known to be the individual(s) described in
and who executed the within and foregoing instrument and acknowledged that they signed the same as
their free and voluntary act and deed, for the uses and purposes therein stated.
Given under my hand and official seal this _____ day of ____________________, 20_____.
Printed name
Notary Public in and for the State of Washington,
residing at
My appointment expires
Exhibit A
Exhibit B
PERMEABLE PAVEMENT MAINTENANCE INSTRUCTIONS Your property contains a stormwater management flow control BMP (best management practice) called"permeable pavement," which was installed to minimize the stormwater quantity and quality impacts ofsome or all of the paved surfaces on your property. Permeable pavements reduce the amount of rainfallthat becomes runoff by allowing water to seep through the pavement into a free-draining gravel or sandbed, where it can be infiltrated into the ground. Permeable PavementThe type(s) of permeable pavement used on your property is: porous asphaltic concrete, The area covered bypermeable pavement as depicted by the flow control BMP site plan and design details must be maintained as permeable pavement and may not be changed without written approval from the City of Renton. Permeable pavements must be inspected after one major storm each year to make sure it is workingproperly. Prolonged ponding or standing water on the pavement surface is a sign that the system isdefective and may need to be replaced. If this occurs, contact the pavement installer or the City of Renton for further instructions. A typical permeable pavement system has a life expectancy of approximately 25-years. To help extend the useful life of the system, the surface of the permeable pavement should be kept clean andfree of leaves, debris, and sediment through regular sweeping or vacuum sweeping. The owner is responsiblefor the repair of all ruts, deformation, and/or broken paving units.
Seattle Pipe Trades425-277-6680595 Monster RD SW #100Renton, WA 98057Donald Scarberry, PENovadyne Civil Engineers425-753-1869Seattle Pipe TradesAddition24N3E24Renton, WA595 Monster RD SW #100x
Black RiverGreen River ValleyEnhanced Basic WQ / Peak Rate Flow ControlXXZone AHPu/WoSlight2-10%XX
22.5888 NAVDFF EL 1ft above flood level.Training Facility, School, Union1PAPTBD
XXXXXXXXXXXPermeable PavingXTreatment layerin paving sectionPermeable PavingXPermeable Asphalt Pavement
06/19/2015
Ur
AgC
AgC
Ur
InC
AmC
Wo
AmC
So
An
AkF Py
Wo
AgB
RdC
BeC AkF
No
PITS
BeC
Py
Ng
Pu
Py
Py
Tu
AkF
Py
BeD
SkAgB
AgD
Bh
AkF
AgB
AkF
Pc
Py
AgD
Rh
EvC
AkF
Sk
AkF
Sk
BeD
Sk
AkF
EvD
AmC
Py
AgB
Pc
An
No
AmC
InD
Pu
AgD
An
AmB
AmC
Py
EvB
BeC
BeC
PITS
No
RdC
PITS
AgB
AmB
AgB
Rh
AmB
BeC
BeD
AgB
Pu
W
AgD
AgD
BeD
Pu
AgD
No
AgD
Pu
BeD
KpC
AgD
Py
So
AgD
EvC
AgD
Ma
AgB
AmB
EvC
Ma
AgD
Sm
RdE
EvC
EvC
Rh
RdC
EvB
AgD
Ng
EvCTu
EvC
Bh
AgD
EvB
AgD
AgD
Ng
RdE
AgD
AgD
AmB
BeD
AgD
EvC
Ma
EvC
EvDEvB
Sk
Sk
AgD
Sm
EvB
EvD
EvB
RdE
KpD
AmB
InA
KpD
An
Py
Ur
An
Sk
EvC
Ur
Sk
EvD
An Bh
Ur
Py
An
AkF
An EvB
InC
AkF
EvC
UrBeC An
No
AkF
AkF
AnAkF
EvB
AmB
Ur
AgC
AgB
Green RiverG
i
n
g
e
r
C
r
e
e
kJohns C
reek
M
a
y
C
r
e
e
k Coa
l
C
r
e
e
k
Cedar Riv
e
r
Springbrook Creek
Garrison CreekRolling Hills Creek
Big
S
oo
s
C
r
e
e
k
Mill CreekHon
e
y
C
r
e
e
k
Madsen
C
r
ee
kGypsy
C
reek
P
a
n
t
h
e
r
C
r
e
e
k Mo
l
a
s
s
e
s
C
r
e
e
k
Maple
w
oo
d
Cr
e
ek
S
p
r
i
n
g
b
r
o
o
k
C
r
e
e
k
Big
S
o
o
s
C
r
e
e
k
May Creek
May Cree
k
Ma
y
C
r
e
e
k
Mill CreekC
o
a
l
C
r
e
e
k
Ma
d
s
e
n
C
r
e
e
kCedar RiverSpringbrook CreekCe
d
a
r
R
i
v
e
r
Bi
g
S
o
o
s
C
r
e
e
kPanther Creek
May C
r
e
e
kMay CreekCoal
C
r
e
e
k
Panther Creek
Ce
d
a
r
R
i
v
e
r
Madsen CreekMol
a
s
s
e
s
C
r
e
e
kMa
p
l
e
w
o
o
d
C
r
e
e
k
Ma
d
s
e
n
C
r
e
e
k
P
a
n
t
h
e
r
C
r
e
e
kGreen RiverGypsy C
r
e
e
k
Panther Creek
Groundwater Protection Area Boundary
Aquifer Protection Area Zone 1
Aquifer Protection Area Zone 1 Modified
Renton City Limits
City of Renton Soil Survey Map
Public Works
Surface Water Utility
G. Del Rosario
12/22/2009 ´0 0.5 1
Miles
Reference 11-C
SITE
§¨¦405
¬«167
¬«169
Ginger
CreekSpringbrook CreekGarrison CreekKennyda
l
e
C
r
e
e
k
Rol
ling
H
i
l
ls
CreekMadsen Creek
J
o
h
n
s
C
r
e
e
k
Maple
woo
d
Cr
eek
May Creek
Gypsy C
r
e
e
k
Mo
l
a
s
s
e
s
C
r
e
e
k
Panther Creek
Ce
d
a
r
R
i
v
e
r
Mola
s
se
s
C
r
e
e
kThunder
H
i
l
l
s
C
re
e
kGreen RiverMay C
r
e
e
k
Ma
d
s
e
n
C
r
e
e
k
Hon
e
y
C
r
e
e
k
Mill CreekBig
Soos
CreekBi
g
S
o
o
s
C
r
e
e
k
Ce
d
a
r
R
i
v
e
rSpringbrook
CreekBig
Soos
CreekGr
een
R
i
ve
r Ma
d
s
e
n
C
r
e
e
k
S
p
r
i
n
g
b
r
o
o
k
C
r
e
e
k Panther CreekBN Inc RdSR 167Cedar River Trl
S 135th
S
t Rainier AveGreen River TrlSW 27th St
Sidn
e
y
A
v
e
N
Jones Ave NEB
e
a
c
o
n
C
o
a
l
M
i
n
e
R
d
S
S 132n
d
S
t
Industry DrSE 196th
D
r
89th Ave S66
t
h
L
n
S
N 33rd Pl
N 35th St
75th
A
ly
S
SE
6
4
t
h
W
a
y
Fir Ln
Puget Dr SES Avon St
La
ke
Y
o
u
ng
s
T
ra
i
l
W
a
l
k143rd Pl SES
E
1
7
1
s
t
W
a
y
SE
J
o
n
e
s
R
d
SE
8
3
r
d
P
l
183rd Ave SESE 160th Pl
SE 174th StLake Washington TrlLogan Ave NSE 132nd St
SE 91st St
110th Ave SESE 122n
d
S
t
SE 64th St
SE 209th St
NE 27th
S
t
So
o
s
C
r
e
e
k
T
r
lSR 515SE Carr
Rd
Costco Dr Nile Ave NES 32nd St
S Creston St
72nd Ave S77th Ave SEWo
o
d
s
i
d
e
D
r
S
E
S 77th PlSE 68th St
SE 3rd Pl
98th Pl S183rd Way SE113th Pl SES 129th St
M
e
a
d
o
w
L
n
99th Pl S120th Ave SE118th Pl SE83rd Ave SES 23rd St SE 100
th
S
t
S Taft St
Gl
e
n
w
o
o
d
A
v
e
S
E
SE 187th St
S 196th St
184th Pl SE
103rd Pl SES 45th Pl
Lake Youngs Service RdS 36th Pl
S 120th St
N 41st Pl161st Pl SESE 179th P
l
SE 133rd St94th Ave SESE 72nd Pl
S 1
1
6
t
h
P
l
S 126th
S
t
166th Pl SES 55th St
N 38th St
Rosario Pl NES 112th St
Renton Ave SNE 7th St
NE 9th St
87th Ave S105th Ave SEN 8th St
SE 123rd Pl
SE 82nd St
SE 109th St
125th Ave SERipley Ln N191st Pl SEInterurban TrlSE 188th Way
N 31st St90th
Ave
SE
SW 34th St Mon
t
e
re
y
P
l
NE59th Aly SS 48th St 174th Ave SES Myrtle St
129th Ave SEFor
e
s
t
A
v
e
S
NE 4th St61st Ave SS 75th Pl17
1
s
t
A
v
e
S
E
190th Ave SESE 180th St
S 119th St63rd Ave SSE 141st
St
S 199th Pl 80th Pl SS 168th St Benson Rd SAndover Park E184th Ave SE16
9
t
h
A
v
e
S
E
111th Ave SES
E
8
9
t
h
P
l
157th Pl SEDuvall Ave NES 113th St
S 115th St 178th Ave SESE 159th Pl
163rd Pl SESW 41st St
S 117th Pl
Renton Maple Valley Rd
SE 108th St
106th Ave SE188th Ave SESE 128th St
136th Pl SESE 191st St
Kli
c
k
i
t
a
t
D
r Main Ave SSE 2nd St121st Ave SESE 170th StLind Ave SWNE 21st St
West Valley Hwy132nd Ave SENE 8th St122nd Ave SEIn
t
e
r
u
r
b
a
n
A
v
e
S
77th Ave SHard
ie
Ave
SW
SW 19th St
68th Ave SSE 95th Wa
y
SE 200th St
SE 160th St
S 118th Pl
116th Ave SEAvalon Dr173
rd
Av
e
SE177th Ave SESE 102nd St
SE 120th St
SE 72nd St
SE 208th St117th Ave SE85th Pl SE186th Ave SEIsland Dr SMonste
r
R
d
S
W
Forest Dr SE
NE 5th
S
t
76th Ave SSE 121st Pl
96th Ave SNE 25th St
166th Ave SEB
e
a
c
o
n
W
a
y
S 14
3
rd
A
v
e
SES 123rd St84th Ave S80th Ave SES 184th StSE 79th Pl
113th Ave SES 124th St
S 116th St
SE 204th Pl
SE 139th Pl
NE 24th StNE 23rd Pl
NE 2nd St
NE 16th
S
t
164th Ave SESE 168th St
SE 186th St 152nd Ave SE57th Ave SSE 161st St112th Ave SESouthcenter PkwySE 172nd Pl
108th Ave SEPark Ave NNewcast
l
e
G
o
l
f
C
l
u
b
R
d
S 3rd St
118th Ave SE148th Pl SE124th Ave SES 2nd St
SE 63rd St
S
E
1
7
0
t
h
P
l
Ra
i
n
i
e
r
A
v
e
S
66th Ave SPie
rce
Ave
SE
SE
M
a
y
V
a
l
l
e
y
R
d
SE 192nd D
r
N 4th St
109th Ave SESW Grady
W
a
y
SE 65th Pl
151st Ave
SE
Minkler Blvd
S 128th St
SE P
e
t
r
o
v
i
t
s
k
y
R
d
S Tobin St
SE 190th St
S 212th Way156th Ave SEMonroe Ave NE15
9
th
A
v
e
SEE Mercer Way62nd Ave SNE 20th Pl
Aberdeen Ave NE59th Ave S5
6
t
h
P
l
S
SE 201st Pl 168th P
l
SE
SE 116th StNE 10th St
168th Ave SES 188th St
SE 112th St
138th Ave SE80th Ave SS 130th St
92nd Ave SSW 39th StMaule
A
ve
S134th Ave SE65th Ave SMa
p
l
e
V
a
l
l
e
y
H
w
y
SE 184th St
14
0
t
h
W
a
y
S
E
S 194th St Lakemont Blvd SE164th Pl SE13
6
t
h
A
v
e
S
E
NE 6th Pl
Kent Boeing AcRd
S 190th St
S Holly St
Lind Ave NW129th Pl SE180th Ave SE181st Ave SE142nd Ave SESE 144th St
SE
1
6
1
s
t
P
l
S 121st St
S 114th St 135th
P
l
SE148th Ave SEI-5
R
a
m
p
S 194th St 84th Ave SP
e
d
e
s
t
r
i
a
n
W
a
l
k 183rd Ave SEI-405 Ra
m
p
116th Ave SESR 515
N
E
2
7
t
h
S
t
NE 7th St
East Valley RdI-405
F
w
y
SE 188th St
S 132nd St NE 3rd St
Talbot Rd SPrivate Rd
SE May V
a
l
l
e
y
R
d
BN Inc Rd110th Ave SE1
7
1
s
t
A
v
e
S
E
148th Ave SEI-405 FwySE 82n
d
St
SE 120th St 174t
h
Ave
SEPedestrian WalkSE Jones Rd
80th Ave SS 116th
P
l
Private RdPedestrian WalkLake
Youn
gs
T
r
a
i
l
W
a
l
k
SE Jones R
d
SR 167SE 208th St
Ra
i
n
i
e
r
A
v
e
S
Soos Creek TrlPrivate RdS 190th St 116th Ave SEPri
v
a
t
e
R
dSunset Blvd NESE 159th PlSR 167S 200th St
Flow Control Standards
Peak Rate Flow Control Standard (Existing Site Conditions)
Flow Control Duration Standard (Existing Site Conditions)
Flow Control Duration Standard (Forested Conditions)
Renton City Limits
Potential Annexation Area
±
0 1 2Miles
Flow Control Application Map
Printed 1/14/2010
Reference 11-A
SITE
SITE
Geotechnical & Earthquake
Engineering Consultants
GEOTECHNICAL ENGINEERING REPORT
Seattle Pipe Trades Expansion
595 Monster Road SW
Renton, Washington
PROJECT NO. 15-140
June 26, 2015
Prepared for:
Seattle Pipe Trades
3213 Eastlake Avenue E Suite B, Seattle, WA 98102
T. 206.262.0370 F. 206.262.0374
Geotechnical & Earthquake
Engineering Consultants
_______________________________
3213 Eastlake Avenue East Suite B
Seattle, WA 98102-7127
Tel: (206) 262-0370
Fax: (206) 262-0374
June 26, 2015
File No. 15-140
Mr. Scott Rice
Collins Woerman
710 2nd Ave #1400
Seattle, WA 98104-1710
Re: Geotechnical Engineering Report
Seattle Pipe Trades Expansion
595 Monster Road SW
Renton, Washington
Dear Mr. Rice,
Enclosed is our geotechnical report for the design of the foundations for the new addition
to the existing Seattle Pipe Trades building. The existing building, which is supported on
spread footings, was constructed on fill overlying floodplain deposits consisting of loose
sand and soft to medium stiff silt. To provide a consistent level of performance with the
existing structure, the new addition should also be supported on spread footings designed
for an allowable bearing capacity of 2.5 ksf. The silts underlying the site are generally
not susceptible to liquefaction, but some minor settlement may occur as a result of
earthquake ground shaking. The near surface silts underlying the site may be used for
stormwater infiltration as based on an estimated infiltration rate of 0.3 inches per hour.
Sincerely,
W. Paul Grant, P.E.
Principal
Enclosure: Geotechnical Report
15-140 595 Monster Rd.doc PanGEO, Inc. i
TABLE OF CONTENTS
1.0 INTRODUCTION ........................................................................................................1
1.1 SITE AND PROJECT DESCRIPTION ....................................................................................1
1.2 SCOPE OF WORK AND AUTHORIZATION ..........................................................................1
2.0 SITE RECONNAISSANCE ........................................................................................1
3.0 SUBSURFACE CONDITIONS ..................................................................................2
3.1 SOILS ..............................................................................................................................2
3.2 GROUNDWATER ..............................................................................................................2
4.0 CONCLUSIONS AND RECOMMENDATIONS .....................................................2
4.1 SEISMIC DESIGN PARAMETERS ........................................................................................3
4.2 LIQUEFACTION ................................................................................................................3
4.3 SPREAD FOOTING FOUNDATIONS ....................................................................................3
4.4 STRUCTURAL FILL AND COMPACTION .............................................................................4
4.5 FLOOR SLABS ..................................................................................................................4
4.6 STORMWATER INFILTRATION ..........................................................................................5
4.7 PAVEMENT ......................................................................................................................5
5.0 CONSTRUCTION CONSIDERATIONS .................................................................6
5.1 MATERIAL REUSE ...........................................................................................................6
5.2 SURFACE DRAINAGE AND EROSION CONSIDERATIONS ....................................................6
5.3 WET WEATHER EARTHWORK ..........................................................................................6
6.0 CONSTRUCTION SUPPORT SERVICES ..............................................................7
7.0 LIMITATIONS ............................................................................................................7
REFERENCES ...................................................................................................................9
15-140 595 Monster Rd.doc PanGEO, Inc. ii
LIST OF FIGURES AND APPENDIX (FOLLOWING TEXT)
Figure 1 Vicinity Map
Figure 2 Site and Exploration Plan
LIST OF APPENDICES
Appendix A Summary Exploration Logs
Figure A-1 Terms and Symbols for Boring and Test Pit Logs
Figure A-2 Log of Test Boring B-1
Figure A-3 Log of Test Boring B-2
Appendix B Laboratory Test Results
Figure B-1 Grain Size Distributions, Borings B-1 and B-2
GEOTECHNICAL ENGINEERING REPORT
SEATTLE PIPE TRADES EXPANSION
595 MONSTER ROAD SW
RENTON, WASHINGTON
________________________________________________________________________
1.0 INTRODUCTION
PanGEO, Inc. (PanGEO) completed a geotechnical engineering study to provide
foundation design parameters for the new addition of the existing Seattle Pipe Trades
building in Renton which is located at 595 Monster Road (see Figure 1). The study
included evaluating the subsurface conditions at the site and providing recommendations
for the foundation design of the new addition. The following summarizes our findings
and conclusions.
1.1 SITE AND PROJECT DESCRIPTION
The new two story addition will be located on the southeast side of the existing structure
where the ground surface is relatively level at about elevation 25 feet. The new addition
will encompass existing landscape and paved parking areas. The existing paved parking
will be removed and reconstructed to the southeast. On-site stormwater infiltration will
be incorporated into the new construction.
1.2 SCOPE OF WORK AND AUTHORIZATION
Our work was accomplished in accordance with our proposal letter dated April 14, 2015,
which was authorized by Mr. Scott Rice with Collins Woerman May 8th. Our work scope
included reviewing existing geotechnical data for the site and nearby locations and
advancing two borings adjacent to the existing building to explore subsurface conditions
and provide the basis from which we developed design recommendations for the
proposed expansion.
2.0 SITE RECONNAISSANCE
On June 2, 2015, we conducted a site reconnaissance to mark locations of the proposed
borings and observe any potential indication of differential settlement of the existing
paved parking areas and the building. As a result of our reconnaissance, we did not
observe any indication of significant settlement of the building. However, we did
observe settlement and cracking of the pavements in the parking lots suggesting that the
fill beneath the pavement has settled.
15-140 595 Monster Rd.doc PanGEO, Inc. 2
3.0 SUBSURFACE CONDITIONS
3.1 SOILS
Subsurface conditions at the site were inferred from the results of two new borings that
were drilled at the locations shown on Figure 2. Both borings were drilled to depths of
25 to 26 feet below the existing ground surface using hollow stem auger drilling
equipment. Soil samples were taken in the borings at 2.5 foot intervals in the upper 10
feet of the borings and at 5 foot intervals thereafter. All sampling was conducted using
the Standard Penetration Test (SPT) procedures. Summary logs of the borings are
presented in Appendix A.
Based upon the materials encountered in the borings, the site is underlain by recent fill
overlying flood plain deposits, which overlie sandstone of the Tukwila Formation. The
following describes the soils encountered in the explorations:
Recent Fill – Both borings, which were located in the parking lot, encountered 2.5
inches of asphalt overlying loose to medium dense, silty, fine sand (Fill) which
extended to depths of 3 to 4 feet.
Floodplain Deposits – Underlying the fill, both borings encountered floodplain
deposits consisting of approximately 5 to 7 feet of loose silty fine sand
overlying about 10 feet of soft to medium stiff silt and clay.
Bedrock – Bedrock consisting of weak sandstone of the Tukwila Formation was
encountered at a depth of about 20 feet in Boring B-1. While not encountering
bedrock, Boring B-2 encountered a medium dense sand below a depth of 23
feet, which may be alluvium overlying the bedrock.
3.2 GROUNDWATER
Groundwater was inferred at a depth about 14 to 15 feet based on the appearance of the
samples retrieved from the borings.
4.0 CONCLUSIONS AND RECOMMENDATIONS
We recommend supporting the new addition on conventional spread and continuous
footings, similar to the foundations supporting the existing building, to maintain a
consistent level of support to the building and thereby avoid stress concentrations that
might otherwise occur with the use of a mixed foundation system supporting different
building sections. With loose fill underlying the footprint of the new addition, we
recommend over excavating 2 feet of subgrade beneath the new footings and replacing
the soil with structural fill compacted with a Ho-Pac to a dense and unyielding condition.
Detailed design recommendations are presented below.
15-140 595 Monster Rd.doc PanGEO, Inc. 3
4.1 SEISMIC DESIGN PARAMETERS
The following seismic design parameters are consistent with ASCE/SEI 41-13 which
requires analyses for two Basic Safety Earthquakes (BSE’s) corresponding to a 10%
probability of exceedance in 50 years (BSE-1) and a 2% probability of exceedance in 50
years (BSE-2). Furthermore, the BSE-1 earthquake motions may be limited to not
exceed two-thirds of the motions from the BSE-2 event. The following parameters,
which are consistent with the 2008 USGS seismic hazard maps, are recommended for the
seismic design of the building improvements at the site with the following coordinates:
47.614°N, 122.328°W
4.2 LIQUEFACTION
The floodplain deposits below the water table are typically low strength clayey silts to
organic silts that may experience some reduction in strength as a result of strong
earthquake ground shaking. However, because these soils are overlain by nearly 15 feet
of soil that would not experience liquefaction; any slight reduction of strength in the
underlying soft silt is not expected to affect the performance of the existing building or
the new addition.
4.3 SPREAD FOOTING FOUNDATIONS
In our opinion, conventional spread and strip footings may be used to support the new
addition. All footings should be founded a minimum distance of 18 inches below the
finished grade and should have a minimum width of 18 inches. To reduce footing
settlement, we recommend that all footings be over excavated to a depth of 2 feet and the
excavated material replaced with a compacted structural fill, which will also serve as a
working platform for the footing construction. We recommend use of a Ho-Pac to
compact the over-excavated subgrade and the structural fill to a dense and unyielding
condition. All footing excavations should observed by PanGEO to confirm that the
Event Site
Class SS S1
Site Coefficients
Spectral
Response
Parameters
Control
Periods
(sec.)
Design
PGA
(SDS/2.5
)
Fa Fv SxS Sx1 TO TS
BSE-1
(10%/50) D 0.72 0.27 1.22 1.85 0.88 0.50 0.11 0.57 0.35
BSE-2
(2%/50) D 1.46 0.55 1.0 1.50 0.97 0.55 0.11 0.57 0.39
15-140 595 Monster Rd.doc PanGEO, Inc. 4
exposed footing subgrade is consistent with the expected conditions and adequate to
support the building addition.
We recommend that the footings be sized using a maximum allowable bearing pressure
of 2.5 ksf which may be increased by 1/3 for transient conditions such as wind and
seismic loadings.
Total static settlements for the footings as constructed as described above are anticipated
to be on the order of 1 inch. Most settlement will occur during construction as loads are
applied. Total building settlements following a large earthquake are expected to be on
the order of 1 to 2 inches.
Lateral forces from wind or seismic loading may be resisted by the combination of
passive earth pressures acting against the embedded portions of the foundations and by
friction acting on the base of the foundations. Passive resistance values may be
determined using an equivalent fluid weight of 360 pounds per cubic foot (pcf). This
value includes a factor safety of at least 2 assuming that the properly compacted
structural fill will be placed adjacent to the sides of the footings. A coefficient friction of
0.5 may be used to determine the frictional resistance at the base of the footings. This
coefficient includes a factor safety of approximate 1.5.
4.4 STRUCTURAL FILL AND COMPACTION
We recommend using all weather material such as City of Seattle Mineral Aggregate
Type 17 (2003 City of Seattle Standard Specifications, 9-03.12(3)) or WSDOT Gravel
Borrow (9-03.14(1)) for structural fill. The backfill should be moisture conditioned to
within about 3 percent of optimum moisture content, placed in loose, horizontal lifts less
than 8 inches in thickness, and systematically compacted to a dense and relatively
unyielding condition and to at least 95 percent of the maximum dry density, as
determined using test method ASTM D 1557.
4.5 FLOOR SLABS
Slab on grade floors (i.e. floors that are not structurally supported) should be constructed
over subgrade that has been compacted to a dense and unyielding condition. We
recommend use of a modulus of subgrade reaction of 100 pci for the floor slab design.
All floor slabs should be constructed on a minimum 4-inch thick capillary break
consisting of free-draining, crushed rock or well-graded gravel compacted to a firm and
unyielding condition. The capillary break material should have no more than 10 percent
passing the No. 4 sieve and less than 5 percent by weight of the material passing the U.S.
Standard No. 100 sieve. City of Seattle Type 22 material meets this gradation
requirement. We also recommend that a 10-mil polyethylene vapor barrier be placed
below the slab.
15-140 595 Monster Rd.doc PanGEO, Inc. 5
4.6 STORMWATER INFILTRATION
Should pervious pavements be used for the new construction, there must be at least 12
inches of soil below the pavement that is suitable for treating the infiltrating water before
the water reaches the groundwater table. The 2012 Ecology Manual specifies soils
suitable for treatment have a long term infiltration rate of less than 3 inches per hour, a
cation exchange capacity (CEC) greater than or equal to 5.0 meq/100g, and an organic
content (OC) of greater than 1 percent. However, the 2012 LID Technical Guidance
Manual for Puget Sound (WSU 2012) indicates that an organic content of 0.5% would be
acceptable provided that the layer is at least 18” thick. If the above criteria are not meet,
the upper 12 (or 18) inches of soil below the pavement section would need amendment
with organics or fertilizer to fall below the maximum infiltration rate and above the
minimum CEC and OC.
Laboratory tests conducted on the site soils include grain size analyses for estimating
long term infiltration rates and CEC and OC testing. The results of the laboratory testing
are summarized below.
Boring
No.
Sample
Depth
(Ft.)
CEC
(meq/100 g)
OC
(%)
D10
(mm)
D60
(mm)
D90
(mm)
Est. Long Term
(Design)
Infiltration
Rate (in/hr.)
B-1 7.5 20.4 15.6 ~0.02 0.43 6 0.3
B-2 7.5 2.01 6.26 ~0.02 0.30 0.4 0.3
Estimated long term infiltration rates for the site soils of 0.3 inches per hour are based on
the soil type as sandy loam to loamy sand in accordance with the 2005 Stormwater
Manual..
4.7 PAVEMENT
We recommend that the pavement section in areas of automobile parking and drive lanes
with light to moderate commercial vehicles consist of 3 inches of hot mix asphalt (HMA)
overlying 6 inches Crushed Surfacing Base Course (CSBC) (WSDOT 9-03.09(3)) over
subgrade that has been compacted to a dense and unyielding condition. All materials
within the pavement section should be compacted to 95% of the materials maximum dry
density, as determined using test method ASTM D 1557.
15-140 595 Monster Rd.doc PanGEO, Inc. 6
5.0 CONSTRUCTION CONSIDERATIONS
5.1 MATERIAL REUSE
The native on-site soils with silt contents in excess of about 5% may be difficult to
handle and compact during wet weather. If use of the existing soils is planned, any
excavated soil should be stockpiled and protected with plastic sheeting to prevent
softening from rainfall.
5.2 SURFACE DRAINAGE AND EROSION CONSIDERATIONS
Surface runoff can be controlled during construction by careful grading practices.
Typically, this includes the construction of shallow, upgrade perimeter ditches or low
earthen berms to collect runoff and prevent water from entering excavations. Temporary
erosion control may require the use of hay bales on the downhill side of the project to
prevent water from leaving the site and potential storm water detention to trap sand and
silt before the water is discharged to a suitable outlet. All collected water should be
directed to a permanent discharge system such as a storm sewer. It should be noted that
the site soils are prone to surficial erosion. Special care should be taken to avoid surface
water on open cut excavations, and exposed slopes should be protected with visqueen.
Temporary provisions may also be required such as the use of quarry spalls at the
entrance to the construction site to reduce the possibility of the offsite transport of soil on
the truck tires.
Permanent control of surface water and roof runoff should be incorporated in the final
grading design. All collected runoff should be directed into conduits that carry the water
away from the pavement or structure and into storm drain systems or other appropriate
outlets. Adequate surface gradients should be incorporated into the grading design such
that surface runoff is directed away from structures.
5.3 WET WEATHER EARTHWORK
General recommendations relative to earthwork performed in wet weather or in wet
conditions are presented below:
Earthwork should be performed in small areas to minimize subgrade exposure
to wet weather. Excavation or the removal of unsuitable soil should be
followed promptly by the placement and compaction of clean structural fill.
The size and type of construction equipment used may have to be limited to
prevent soil disturbance.
During wet weather, the allowable fines content of the structural fill should be
reduced to no more than 5 percent by weight based on the portion passing ¾-
inch sieve. The fines should be non-plastic.
15-140 595 Monster Rd.doc PanGEO, Inc. 7
The ground surface within the construction area should be graded to promote
run-off of surface water and to prevent the ponding of water.
Bales of straw and/or geotextile silt fences should be strategically located to
control erosion and the movement of soil. Erosion control measures should be
installed along all the property boundaries.
Excavation slopes and soils stockpiled on site should also be covered with
plastic sheets.
.
6.0 CONSTRUCTION SUPPORT SERVICES
The recommendations presented in this report are based on the assumption that an
adequate program of tests and observations will be made during construction to verify
compliance with these recommendations. These tests and observations should include,
by not necessarily be limited to, the following:
Review final project plans and specifications
Verify implementation of erosion control measures
Verify adequacy of subgrades beneath footings, floor slabs and pavements
Confirm the adequacy of compaction of structural backfill
Other consultation as may be required during construction
Pending the completion of the final design drawings, we will provide you a proposal for
construction monitoring services to address the above items. Geotechnical construction
monitoring, by the geotechnical engineer of record, may be required by the City of
Renton to obtain an occupancy permit for the building. We will provide the services
necessary to assure you compliance with the Building Permit.
7.0 LIMITATIONS
We have prepared this report for use by the consultant team for the design of the new
addition. Recommendations contained in this report are based on a site reconnaissance, a
subsurface exploration program, review of pertinent subsurface information, and our
understanding of the project. The study was performed using a mutually agreed-upon
scope of work.
Variations in subsurface conditions may exist between the locations of the explorations
and the actual conditions underlying the site. The nature and extent of soil variations may
not be evident until construction occurs. If any soil conditions are encountered at the site
that are different from those described in this report, we should be immediately notified
15-140 595 Monster Rd.doc PanGEO, Inc. 8
to review the applicability of our recommendations. Additionally, we should also be
notified to review the applicability of our recommendations if there are any changes in
the project scope.
The scope of our work does not include services related to construction safety
precautions and our recommendations are not intended to direct the contractor’s methods,
techniques, sequences or procedures, except as specifically described in our report for
consideration in design. Additionally, the scope of our work specifically excludes the
assessment of environmental characteristics, particularly those involving hazardous
substances.
This report has been prepared for planning and design purposes for specific application to
the proposed project in accordance with the generally accepted standards of local practice
at the time this report was written. No warranty, express or implied, is made.
This report may be used only by the client and for the purposes stated, within a
reasonable time from its issuance. Land use, site conditions (both off and on-site), or
other factors including advances in our understanding of applied science, may change
over time and could materially affect our findings. Therefore, this report should not be
relied upon after 24 months from its issuance. PanGEO should be notified if the project
is delayed by more than 24 months from the date of this report so that we may review the
applicability of our conclusions considering the time lapse.
It is the client’s responsibility to see that all parties to this project, including the designer,
contractor, subcontractors, etc., are made aware of this report in its entirety. The use of
information contained in this report for bidding purposes should be done at the
contractor’s option and risk. Any party other than the client who wishes to use this report
shall notify PanGEO of such intended use and for permission to copy this report. Based
on the intended use of the report, PanGEO may require that additional work be performed
and that an updated report be reissued. Noncompliance with any of these requirements
will release PanGEO from any liability resulting from the use this report.
W. Paul Grant, P.E.
Principal Geotechnical Engineer
15-140 595 Monster Rd.doc PanGEO, Inc. 9
REFERENCES
International Building Code (IBC), 2012, International Code Council
Washington State Department of Transportation (WSDOT), 2014, Standard
Specifications for Road, Bridge, and Municipal Construction M 41-10: Washington State
Department of Transportation.
Washington State Department of Ecology, 2012, Stormwater Management Manual for
Western Washington: Report prepared by the WSDOE, August
Washington State University, 2012, Low Impact Development Technical Guidance
Manual for Puget Sound: Washington State University Extension and Puget Sound
Partnership, Publication PSP 2012-3.
Figure No.Project No.
Seattle Pipe Trades Expansion
595 Monster Road
Renton, Washington
15-140 1
VICINITY MAP
Base map from Google
Project
Location
N
Figure No.Project No.
Seattle Pipe Trades Expansion
595 Monster Road
Renton, Washington
15-140 2
Site and Exploration Plan
Base map from Google
N
B-2
B-1
APPENDIX A
Summary Exploration Logs
MOISTURE CONTENT
2-inch OD Split Spoon, SPT
(140-lb. hammer, 30" drop)
3.25-inch OD Spilt Spoon
(300-lb hammer, 30" drop)
Non-standard penetration
test (see boring log for details)
Thin wall (Shelby) tube
Grab
Rock core
Vane Shear
Dusty, dry to the touch
Damp but no visible water
Visible free water
Terms and Symbols for
Boring and Test Pit Logs
Density
SILT / CLAY
GRAVEL (<5% fines)
GRAVEL (>12% fines)
SAND (<5% fines)
SAND (>12% fines)
Liquid Limit < 50
Liquid Limit > 50
Breaks along defined planes
Fracture planes that are polished or glossy
Angular soil lumps that resist breakdown
Soil that is broken and mixed
Less than one per foot
More than one per foot
Angle between bedding plane and a planenormal to core axis
Very Loose
Loose
Med. Dense
Dense
Very Dense
SPT
N-values
Approx. Undrained Shear
Strength (psf)
<4
4 to 10
10 to 30
30 to 50
>50
<2
2 to 4
4 to 8
8 to 15
15 to 30
>30
SPT
N-values
Units of material distinguished by color and/orcomposition from material units above and below
Layers of soil typically 0.05 to 1mm thick, max. 1 cm
Layer of soil that pinches out laterally
Alternating layers of differing soil material
Erratic, discontinuous deposit of limited extent
Soil with uniform color and composition throughout
Approx. Relative
Density (%)
Gravel
Layered:
Laminated:
Lens:
Interlayered:
Pocket:
Homogeneous:
Highly Organic Soils
#4 to #10 sieve (4.5 to 2.0 mm)
#10 to #40 sieve (2.0 to 0.42 mm)
#40 to #200 sieve (0.42 to 0.074 mm)
0.074 to 0.002 mm
<0.002 mm
UNIFIED SOIL CLASSIFICATION SYSTEM
MAJOR DIVISIONS GROUP DESCRIPTIONS
Notes:
MONITORING WELL
<15
15 - 35
35 - 65
65 - 85
85 - 100
GW
GP
GM
GC
SW
SP
SM
SC
ML
CL
OL
MH
CH
OH
PT
TEST SYMBOLS
50%or more passing #200 sieve
Groundwater Level at time of drilling (ATD)Static Groundwater Level
Cement / Concrete Seal
Bentonite grout / seal
Silica sand backfill
Slotted tip
Slough
<250
250 - 500
500 - 1000
1000 - 2000
2000 - 4000
>4000
RELATIVE DENSITY / CONSISTENCY
Fissured:
Slickensided:
Blocky:
Disrupted:
Scattered:
Numerous:
BCN:
COMPONENT DEFINITIONS
Dry
Moist
Wet
1. Soil exploration logs contain material descriptions based on visual observation and field tests using a systemmodified from the Uniform Soil Classification System (USCS). Where necessary laboratory tests have beenconducted (as noted in the "Other Tests" column), unit descriptions may include a classification. Please refer to thediscussions in the report text for a more complete description of the subsurface conditions.
2. The graphic symbols given above are not inclusive of all symbols that may appear on the borehole logs.Other symbols may be used where field observations indicated mixed soil constituents or dual constituent materials.
COMPONENT SIZE / SIEVE RANGE COMPONENT SIZE / SIEVE RANGE
SYMBOLS
Sample/In Situ test types and intervals
Silt and Clay
Consistency
SAND / GRAVEL
Very Soft
Soft
Med. Stiff
Stiff
Very Stiff
Hard
Phone: 206.262.0370
Bottom of BoringBoulder:
Cobbles:
Gravel
Coarse Gravel:
Fine Gravel:
Sand
Coarse Sand:
Medium Sand:
Fine Sand:
Silt
Clay
> 12 inches
3 to 12 inches
3 to 3/4 inches
3/4 inches to #4 sieve
Atterberg Limit Test
Compaction Tests
Consolidation
Dry Density
Direct Shear
Fines Content
Grain Size
Permeability
Pocket Penetrometer
R-value
Specific Gravity
Torvane
Triaxial Compression
Unconfined Compression
Sand
50% or more of the coarsefraction passing the #4 sieve.Use dual symbols (eg. SP-SM)for 5% to 12% fines.
for In Situ and Laboratory Testslisted in "Other Tests" column.
50% or more of the coarsefraction retained on the #4sieve. Use dual symbols (eg.GP-GM) for 5% to 12% fines.
DESCRIPTIONS OF SOIL STRUCTURES
Well-graded GRAVEL
Poorly-graded GRAVEL
Silty GRAVEL
Clayey GRAVEL
Well-graded SAND
Poorly-graded SAND
Silty SAND
Clayey SAND
SILT
Lean CLAY
Organic SILT or CLAY
Elastic SILT
Fat CLAY
Organic SILT or CLAY
PEAT
ATT
Comp
Con
DD
DS
%F
GS
Perm
PP
R
SG
TV
TXC
UCC
LOG KEY 13-113 LOG.GPJ PANGEO.GDT 9/18/13Figure A-1
GS
Asphalt 2.5 inches.
Medium dense, green gray, silty, fine SAND. (Fill).
Stiff, dark green gray, organic SILT with clay: moist, slightly plastic, somefine sand, wood fibers, laminated. (Floodplain Deposit).
Loose, multi-colored, silty, fine SAND: moist, non-plastic fines with rapiddilatancy, some sub-rounded gravel, trace to some organics, laminated
with possible peaty laminae. (Floodplain Deposit).
Loose, dark green gray, silty, fine to coarse SAND (SM) with organics: wet,occasional light brown clay clast, non-plastic fines, laminated and beddedwith silt/clay interbeds, coaly organics. (Floodplain Deposit).
Stiff, light gray SILT: wet, slightly plastic, rapid dilatancy, laminated,homogeneous,rusty lenses. (Floodplain Deposit).
Soft to medium stiff, interbedded gray SILT and brown organic SILT: wet,
non-plastic, rapid dilatancy, to slightly plastic, peaty organics in brownbeds, laminated. (Floodplain Deposit).
Very weak, light gray, tuffaceous, fine SANDSTONE. (Tukwila
Formation).
Bottom of Boring.
S-1
S-2
S-3
S-4
S-5
S-6
S-7
355
233
242
553
214
50/4
50/6
Remarks: Groundwater measured in open boring following extraction of augers.
0
5
10
15
20
25
30
The stratification lines represent approximate boundaries. The transition may be gradual.
MATERIAL DESCRIPTION
Figure A-2Other TestsSample No.Completion Depth:
Date Borehole Started:
Date Borehole Completed:
Logged By:
Drilling Company:Depth, (ft)Proposed Building Addition
15-140
595 Monster Road, Renton, WA
Northing: , Easting:
25.5ft
6/6/15
6/6/15
S. Evans
BoreTec, Inc
Sheet 1 of 1
Project:
Job Number:
Location:
Coordinates:SymbolSample TypeBlows / 6 in.24.0ft
HSA
SPT
Surface Elevation:
Top of Casing Elev.:
Drilling Method:
Sampling Method:
LOG OF TEST BORING B-1
N-Value
0
Moisture LL
50
PL
RQD Recovery
100
>>
>>
GS
Asphalt 5 inches.
Medium dense, green gray, silty, fine SAND with gravel. (Fill).
Medium dense multi-colored brown/gray/green, silty, fine SAND to sandySILT: moist, slightly plastic fines, trace gravel, organic fibers, mixed
texture, layered. (Fill).
Medium stiff, brown/dark gray/light gray, fine sandy SILT: moist, slightlyplastic, slow dilatancy, trace gravel, trace to some organics, laminated withoccasional rusty laminae, dips 5 - 10o. (Floodplain Deposit).
Loose, yellow brown, silty, fine SAND (SM): very moist to wet, slightlyplastic fines, rapid dilatancy, occasional sst gravel, trace coarse medium to
coarse, sand, massive, homogeneous. (Floodplain Deposit).
Grading yellow-red brown, very silty, fine SAND, wet, dark gray, organic siltwith peaty material in tip.
Soft, green gray with vermilion lenses, clayey SILT to silty CLAY: wet, low
plastic, rapid and no dilatancy layers, laminated with occasional organiclaminae, rusty pockets. (Floodplain Deposit).
Soft, interlaminated gray and light brown gray, fine sandy SILT: wet,non-plastic to slightly plastic, rapid to slow dilatancy, laminated with peatyorganics on laminae. (Floodplain Deposit).
Medium dense, dark gray, fine to medium SAND: wet, trace to some silt,homogeneous, laminated to massive. (Alluvium).
Bottom of Boring.
S-1
S-2
S-3
S-4
S-5
S-6
S-7
647
345
212
121
222
212
788
Remarks: Groundwater measured in open boring following extraction of augers.
0
5
10
15
20
25
30
The stratification lines represent approximate boundaries. The transition may be gradual.
MATERIAL DESCRIPTION
Figure A-3Other TestsSample No.Completion Depth:
Date Borehole Started:
Date Borehole Completed:
Logged By:
Drilling Company:Depth, (ft)Proposed Building Addition
15-140
595 Monster Road, Renton, WA
Northing: , Easting:
26.5ft
6/6/15
6/6/15
S. Evans
BoreTec, Inc
Sheet 1 of 1
Project:
Job Number:
Location:
Coordinates:SymbolSample TypeBlows / 6 in.25.0ft
HSA
SPT
Surface Elevation:
Top of Casing Elev.:
Drilling Method:
Sampling Method:
LOG OF TEST BORING B-2
N-Value
0
Moisture LL
50
PL
RQD Recovery
100
15-140 595 Monster Rd.doc PanGEO, Inc. 2
APPENDIX B
Laboratory Test Results
0
10
20
30
40
50
60
70
80
90
100
0.0010.010.1110100
Specimen Identification
1.5
NP
NP
D100
NP
NP
PI
16
D10
GRAIN SIZE DISTRIBUTION
19.05
9.525
8
Cc
13.4
0.8
404
GRAVEL
B-1
B-2
COBBLES SAND
fine
6 2
coarse
PL
20
%Clay
1001403
D30
fine
30 200
33.0
30.5
SILT OR CLAY
4
@ 7.5 ft.
@ 7.5 ft.PERCENT FINER BY WEIGHTClassification
7.5
7.5
B-1
B-2
CuLL
3
D60 %Gravel
53.6
68.7
SILTY SAND(SM)
SILTY SAND(SM)
60
Specimen Identification
1/23/81
%Silt
medium
6 10 14
NP
NP
50
HYDROMETERU.S. SIEVE OPENING IN INCHES
Figure
U.S. SIEVE NUMBERS
Figure
0.431
0.301
coarse
%Sand
GRAIN SIZE IN MILLIMETERS
3/4
Figure
B-1
Project: Proposed Building Addition
Job Number: 15-140
Location: 595 Monster Road, Renton, WAPhone: 206.262.0370
GRAIN SIZE 15-140 LOGS.GPJ PANGEO.GDT 6/26/15