HomeMy WebLinkAboutSEA Garden Ave Elevations and Plans 190213LEGAL DESCRIPTION
APPROVED BY
CONSTRUCTION MANAGER
DATE SIGNATURE
PROJECT MANAGER
SITE ACQUISITION
ZONING
APPROVAL / SIGN OFF
PROJECT CONTACT LIST
PROJECT INFORMATION
UTILITY COMPANIES
RF
LDC, INC.
CONTACT: RICHARD B. HALL, AIA
PHONE: (425) 806-1869
EMAIL: rhall@ldccorp.com
PROJECT ARCHITECT:
APPLICANT:PROPERTY OWNER:
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
FROM VERIZON WIRELESS OFFICE:
x HEAD EAST TOWARD 158TH AVE SE
x TURN RIGHT ONTO 158TH AVE SE
x TURN RIGHT ONTO SE EASTGATE WAY
x TURN LEFT ONTO THE I-90 W RAMP TO SEATTLE
x KEEP LEFT, FOLLOW SIGNS FOR I-90 W/SEATTLE AND MERGE
ONTO I-90 W
x MERGE ONTO I-90 W
x USE THE RIGHT 2 LANES TO TAKE EXIT 10 FOR INTERSTATE 405
S TOWARD RENTON
x MERGE ONTO I-405 S
x TAKE EXIT 5 TOWARD WA-900 E/PARK AVENUE NORTH/SUNSET
BLVD N.E
x TURN RIGHT ONTO NE PARK DR (SIGNS FOR PARK AVENUE N)
x CONTINUE STRAIGHT ONTO LOGAN AVE N
x TURN LEFT ONTO NORTH LANDING WAY
x DESTINATION WILL BE ON THE RIGHT
DRIVING DIRECTIONS
VERIZON WIRELESS
3245 158TH AVENUE SE
BELLEVUE, WA 98008
VERIZON WIRELESS PROPOSES TO CONSTRUCT AN UNMANNED
TELECOMMUNICATIONS FACILITY CONSISTING OF (6) PANEL ANTENNAS
WITHIN (3) FRP SHROUDS, AND (2) MICROWAVES WITHIN (2) FRP
CANISTERS MOUNTED ON AN EXISTING 29.15' BUILDING; ALSO, A FENCED
EQUIPMENT LEASE AREA WITHIN AN EXISTING CMU ENCLOSED REFUSE
AREA.
MICROWAVE
(ON SITE)
TELEPHONE:POWER:
PUGET SOUND ENERGY
PHONE: (888) 225-5773
ZONING CLASSIFICATION:
CODE INFORMATION:
UC (URBAN CENTER)
BUILDING CODE:IBC 2015
CONSTRUCTION TYPE:IIIA
OCCUPANCY:B, M, S-2
JURISDICTION:CITY OF RENTON
PROPOSED BUILDING USE:UNMANNED TELECOM
LATITUDE:
SITE LOCATION (NAD83):
1
LONGITUDE:
:
TOP OF STRUCTURE:57.65
$06/
BASE OF STRUCTURE:28.50
$06/
PROJECT LEASE AREA:
0886600040
PARCEL NUMBER:
AREA OF PARCEL:NEW IMPERVIOUS AREA:
1.PARKING REQUIREMENTS ARE UNCHANGED.
2.TRAFFIC IS UNAFFECTED.
3.SIGNAGE IS UNAFFECTED.
GENERAL INFORMATION:
PROJECT DESCRIPTION:
29.15
$*/
$*/
1
:
VICINITY MAP
NOT TO SCALE
GENERAL LOCATION MAP
NOT TO SCALE
PROJECT
PROJECT
CPT THE LANDING LLC
LDC, INC.
CONTACT: JESSICA WREN, PE, SE
PHONE: (425) 806-1869
EMAIL: jwren@ldccorp.com
PROJECT ENGINEER:
TITLE SHEET
T-1.0
LANDLORD
811 N LANDING WAY
RENTON, WA 98057
SEA GARDEN AVE
DRAWING INDEX
DWG NO.DESCRIPTION
T-1.0 TITLE SHEET
A-1.0 SITE PLAN
A-1.1 ROOF PLAN
A-1.2 GROUND EQUIPMENT PLAN
A-2.0 ENLARGED SITE PLAN - ANTENNAS
A-2.1 ENLARGED SITE PLAN - EQUIPMENT
A-3.0 ELEVATIONS
A-3.1 ELEVATIONS
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY ZONING RJG
3 1-30-18 RPZD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING ENS
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
PROJECT CONSULTANT:
LDC, INC.
CONTACT: RICK CARDOZA
PHONE: (253) 218-9017
EMAIL: rcardoza@ldccorp.com
144 SF
N/A 18.21 ACRES
THE INFORMATION CONTAINED IN THIS SET OF
CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE.
ANY USE OR DISCLOSURE OTHER THAN THAT WHICH
RELATES TO VERIZON WIRELESS. SERVICES IS STRICTLY
PROHIBITED.
PROPRIETARY INFORMATION
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION.
DISCLAIMERS
LOTS 1A AND 4A OF CITY OF RENTON LOT LINE ADJUSTMENT
LUA-06-057-LLA, RECORDED UNDER RECORDING NUMBER
20060808900001 IN THE RECORDS OF KING COUNTY,
WASHINGTON, SITUATE IN THE CITY OF RENTON, COUNTY
OF KING, STATE OF WASHINGTON.
LOT 1 OF THE CITY OF RENTON SHORT PLAT
LUA-06-069-SPHL, RECORDED UNDER RECORDING NUMBER
20061024900005, IN THE RECORDS OF KING COUNTY,
WASHINGTON SITUATE IN THE CITY OF RENTON, COUNTY OF
KING, STATE OF WASHINGTON.
1
ZONING:
UC (URBAN CENTER)
ADJACENT ZONING:
UC (URBAN CENTER)
ZONING MAP
NOT TO SCALE
PROPOSED QUANTITIES
POWER LENGTH:
27'
FIBER/TELCO LENGTH:
103'
260'
UNDERGROUND:
OVERHEAD:
132'
SITE PLAN
22"x34" SCALE: 1" = 60'11"x17" SCALE: 1" = 120'
PROJECT
PROPOSED VERIZON WIRELESS FENCED
LEASE AREA WITHIN AN EXISTING CMU
ENCLOSED REFUSE AREA
PROPOSED VERIZON WIRELESS ANTENNAS WITHIN
AN FRP SHROUD ON AN EXISTING 29.15' BUILDING
EXISTING SITE ACCESS
SITE PLAN
A-1.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY ZONING RJG
3 1-30-18 RPZD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING ENS
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
IH
ADJACENT ZONING:
UC (URBAN CENTER)
EXISTING ROOF ACCESS HATCH
ADJACENT ZONING:
UC (URBAN CENTER)
ADJACENT ZONING:
UC (URBAN CENTER)
1
ANTENNA SETBACK
ANTENNA SETBACK
EQUIPMENT SETBACK
EQUIPMENT SETBACK
EQUIPMENT SETBACK
$17(11$SETBACKPROPOSED VERIZON WIRELESS MICROWAVE WITHIN
AN FRP CANISTER ON AN EXISTING 29.15' BUILDING
UNDERGROUND:
OVERHEAD:
PROPOSED FIBER HANDHOLE
1
1
1
ROOF PLAN
22"x34" SCALE: 1/8" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
ROOF PLAN
A-1.1
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY ZONING RJG
3 1-30-18 RPZD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING ENS
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
1
EXISTING ROOF
ACCESS HATCH
PROPOSED VERIZON WIRELESS
ANTENNAS WITHIN AN FRP SHROUD
ON AN EXISTING 29.15' BUILDING
EXISTING HVAC
UNIT, TYP
EXISTING VENT, TYP
EXISTING ROOFTOP
DRAIN, TYP
EXISTING PARKING LINE, TYP
EXISTING CURB, TYP
EXISTING LANDSCAPING,
TYP (TO REMAIN)
EXISTING PARKING LOT (TO REMAIN)
PROPOSED VERIZON
WIRELESS MICROWAVE
WITHIN AN FRP CANISTER ON
AN EXISTING 29.15' BUILDING
EXISTING
PENTHOUSE
EXISTING ELECTRICAL
ROOM (BELOW)
EXISTING NATURAL
GAS METER & PIPING
EXISTING SIDEWALK
EXISTING
BUILDING
EXISTING
BUILDING
1GROUND EQUIPMENT PLAN
22"x34" SCALE: 1/8" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
GROUND EQUIPMENT PLAN
A-1.2
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY ZONING RJG
3 1-30-18 RPZD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING ENS
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
EXISTING PARKING LINE, TYP
EXISTING CURB
EXISTING PARKING LOT
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING SEWER DRAIN
PROPOSED FIBER
HANDHOLE
PROPOSED FIBER SERVICE ORIGINATING FROM
A NEW FIBER HANDHOLE (LOCATED AT N 8TH ST
NEAR THE REAR ACCESS LOADING AREA FOR
THE SUBJECT RETAIL BUSINESS) AND
CONTINUING TO EQUIPMENT AREA VIA BURIED
CONDUIT WITHIN UNDERGROUND TRENCH
PROPOSED VERIZON WIRELESS GROUNDING WITH
GROUND RODS PARALLELING N 8TH STREET
ADJACENT VERIZON WIRELESS EQUIPMENT AREA
PROPOSED VERIZON WIRELESS HYBRID CABLE
ROUTING FROM PROPOSED EQUIPMENT AREA TO
EXTERIOR WALL ALONG WEST FACADE OF
ADJACENT RETAIL BUSINESS AND TRANSFERING
TO SOUTH FACADE OF SUBJECT RETAIL BUSINESS
TO DESIGNATED TRANSITION POINT ROUTING TO
ROOFTOP CONCEALED ANTENNA SECTORS
EXISTING ELECTRICAL
ROOM (BELOW)
EXISTING SITE ACCESS
1
PROPOSED VERIZON WIRELESS
FENCED LEASE AREA WITHIN AN
EXISTING CMU ENCLOSED
REFUSE AREA
EXISTING REFUSE AREA
(BELOW)
1
1
ENLARGED SITE PLAN - ANTENNAS
22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0"SECTOR 3 : 315SECT
O
R
2
:
240 MW : 202.33MW : 64.55
ENLARGED SITE PLAN -
ANTENNAS
A-2.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY ZONING RJG
3 1-30-18 RPZD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING ENS
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
CONSTRUCTION PLAN KEYED NOTES
1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2.ANALYSIS OF BUILDING SHALL BE PERFORMED BY LDC & STAMPED BY
A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED POWER & FIBER ROUTING.
PROPOSED VERIZON WIRELESS HYBRID CABLE TO ANTENNAS (3 TOTAL).
PROPOSED (4) 4" SCHED. 40 PVC CONDUIT.
PROPOSED VERIZON WIRELESS CABLE SUPPORTS, TYP.
352326('9(5,=21:,5(/(6
)53&$1,67(5$66(0%/<727$/.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 2 PER SECTOR, 6 TOTAL).
PROPOSED VERIZON WIRELESS DIPLEXER
(TYP 6 PER SECTOR, 18 TOTAL).
352326('9(5,=21:,5(/(66
0,&52:$9(727$/.
PROPOSED VERIZON WIRELESS FRP SHROUD ASSEMBLY (3 TOTAL).
PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX
(3 TOTAL).
EXISTING 29.15' BUILDING (TO REMAIN).
PROPOSED VERIZON WIRELESS RRUS 32 UNIT
(TYP 2 PER SECTOR, 6 TOTAL).
PROPOSED VERIZON WIRELESS RRUS 11 UNIT
(TYP 2 PER SECTOR, 6 TOTAL).
3
4
5
6
11
12
13
14
15
16
21
29
30
EXISTING PENTHOUSE
SE
C
T
O
R
1
:
120
2
1
5'-0"PROPOSED 8'-0"
FRP SHROUD
PROPOSED 8'-0"FRP SHROUD5'-0"3'-0"PENTHOUSE OVERHANG5'-0"PROPOSED 8'-0"FRP SHROUDPROPOSED 8'-0"
FRP SHROUD
5'-0"
EXISTING NATURAL
GAS METER & PIPINGEXISTING SIDEWALK 5'-0"PROPOSED 8'-0"FRP SHROUD 4'-6"10'-0"
(BELOW)
EXISTING ROOF
ACCESS HATCH
3
4
6
11
12
14 15
21
29
30
5
555
EXISTING ELECTRICAL
ROOM (BELOW)
5
54
EXISTING BEAM (BLOW)4'-6"611
21
16
14
BUILDING CANOPY (BELOW)
15
EXISTING BUILDING5'-0"214'-6"13
21
21
EXISTING
NG VALVE EXISTING
ROOFTOP VENT
EXISTING
ROOFTOP VENT
4'-6"
5 54'-6"
5
5PROPOSED 8'-0"
FRP SHROUD4'-6"55
1ENLARGED SITE PLAN - EQUIPMENT
22"x34" SCALE: 3/8" = 1'-0"11"x17" SCALE: 3/16" = 1'-0"
ENLARGED SITE PLAN -
EQUIPMENT
A-2.1
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY ZONING RJG
3 1-30-18 RPZD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING ENS
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
CONSTRUCTION PLAN KEYED NOTES
1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2.ANALYSIS OF BUILDING SHALL BE PERFORMED BY LDC & STAMPED BY
A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED VERIZON WIRELESS LED SERVICE LIGHT, TYP (2 TOTAL).
PROPOSED POWER & FIBER ROUTING.
PROPOSED VERIZON WIRELESS 8'-0" TALL CHAIN LINK FENCE
W/ PRIVACY SLATS. STRUCTURAL PENDING
PROPOSED VERIZON WIRELESS CHAIN LINK ACCESS
GATE W/ PRIVACY SLATS AND LOCKING MECHANISM.
VZW SIGNAGE MOUNTED TO GATE.
PROPOSED VERIZON WIRELESS HYBRID CABLE TO ANTENNAS (3 TOTAL).
PROPOSED (4) 4" SCHED. 40 PVC CONDUIT.
PROPOSED VERIZON WIRELESS EQUIPMENT CONCRETE PAD.
STRUCTURAL PENDING.
PROPOSED VERIZON WIRELESS GPS ANTENNA (1 TOTAL).
6,7(72%(),//(':,7+2)&586+('52&.
W/ WEED BARRIER ON 95% COMPACTED FILL.
PROPOSED VERIZON WIRELESS TELCO/FIBER CABINET.
PROPOSED VERIZON WIRELESS ILC CABINET.
EXISTING 29.15' BUILDING (TO REMAIN).
PROPOSED VERIZON WIRELESS 20KW DIESEL
GENERATOR.
PROPOSED VERIZON WIRELESS METER BASE.
PROPOSED VERIZON WIRELESS UTILITY H-FRAME.
PROPOSED VERIZON WIRELESS PDU/BATTERY CABINET (1 TOTAL).
PROPOSED VERIZON WIRELESS EQUIPMENT LEASE AREA.
PROPOSED VERIZON WIRELESS RADIO CABINET WITH
(3) PRE-INSTALLED RAYCAP OVP DEVICES (1 TOTAL).
PROPOSED BOLLARD, TYP (4 TOTAL).
1
2
4
8
9
10
14
16
17
19
20
21
22
23
24
25
26
27
28
2
1
PROPOSED
VERIZON WIRELESS
16'-0" EQUIPMENT PAD PROPOSEDVERIZON WIRELESS8'-0" EQUIPMENT PADEXISTING PARKING
PROPOSED VERIZON WIRELESS9'-0" FENCED LEASE AREA2
4
20
19 22
23 2PROPOSED VERIZON WIRELESS
20'-9" FENCED LEASE AREA
1 97'-7"1416
21
6"
6"2'-8"26SEE SHEET A-1.1 FOR ROOFTOP
ANTENNA SITE PLAN.
8
15'-0"
PROPOSED
VERIZON WIRELESS
8'-0" DOUBLE WIDE
ROLLING GATE
7'-9"10
24
27 284'-5"
6"
1'-0"
4'-3"
6"
6"
6"2'-8"9"9"EXISTING
BUILDING
21
25
EXISTING
REFUSE AREA
3'-0"
TYP
4'-8"17
1PROPOSED NORTH ELEVATION (LOOKING SOUTH)
22"x34" SCALE: 1/8" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
ELEVATIONS
A-3.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY ZONING RJG
3 1-30-18 RPZD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING ENS
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
CONSTRUCTION PLAN KEYED NOTES
1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2.ANALYSIS OF BUILDING SHALL BE PERFORMED BY LDC & STAMPED BY
A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
352326('9(5,=21:,5(/(6
)53&$1,67(5$66(0%/<727$/.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 2 PER SECTOR, 6 TOTAL).
352326('9(5,=21:,5(/(66
0,&52:$9(727$/.
PROPOSED VERIZON WIRELESS FRP SHROUD ASSEMBLY (3 TOTAL).
EXISTING 29.15' BUILDING (TO REMAIN).4
5
6
11
12
4
TOP OF PROPOSED VERIZON
WIRELESS FRP ANTENNA SHROUD
28.50' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
28.25' AGL
TOP OF PROPOSED VERIZON
WIRELESS FRP MICROWAVE CANISTER
28.50' AGL
RAD CENTER OF PROPOSED
VERIZON WIRELESS MICROWAVE
27.50' AGL
5
12
6
11
TOP OF EXISTING ROOFTOP
18.00' AGL
TOP OF EXISTING LOWER PARAPET
20.5' AGL
TOP OF EXISTING BUILDING
29.15' AGL
TOP OF EXISTING UPPER PARAPET
22.25' AGL
FINISH GRADE
0.0' AGL
2
1PROPOSED SOUTH ELEVATION (LOOKING NORTH)
22"x34" SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16" = 1'-0"
PROPOSED WEST ELEVATION (LOOKING EAST)
22"x34" SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16" = 1'-0"
TOP OF EXISTING BUILDING
29.15' AGL
ELEVATIONS
A-3.1
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
17-808
SEA GARDEN AVE
811 N LANDING WAY
RENTON, WA 98057
9-13-17
KTL
RBH
1 9-13-17 PRELIMINARY ZONING KTL
2 11-27-17 PRELIMINARY CONSTRUCTION RJG
3 1-30-18 RPCD: ADD STRUCT. & DETAILS ENS
4 4-9-18 RPZD: MOVE EQUIPMENT AREA RJG
5 4-12-18 FINAL ZONING RJG
6 9-19-18 RPCD: COMMENTS ENS
8828
PRELI
MI
N
A
R
Y
Surveying
Engineering
Planning
ANNIVERSARYth
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
CONSTRUCTION PLAN KEYED NOTES
1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2. ANALYSIS OF BUILDING SHALL BE PERFORMED BY LDC & STAMPED BY
A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED VERIZON WIRELESS LED SERVICE LIGHT, TYP (2 TOTAL).
PROPOSED POWER & FIBER ROUTING WITHIN (2) 2" SCHED .40 PVC
CONDUIT.
PROPOSED VERIZON WIRELESS 8'-0" TALL CHAIN LINK FENCE
W/ PRIVACY SLATS. STRUCTURAL PENDING
PROPOSED VERIZON WIRELESS HYBRID CABLE TO ANTENNAS (3 TOTAL).
PROPOSED (4) 4" SCHED. 40 PVC CONDUIT.
352326('9(5,=21:,5(/(6
)53&$1,67(5$66(0%/<727$/.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED VERIZON WIRELESS GPS ANTENNA (1 TOTAL).
352326('9(5,=21:,5(/(66
0,&52:$9(727$/.
PROPOSED VERIZON WIRELESS TELCO/FIBER CABINET.
PROPOSED VERIZON WIRELESS ILC CABINET.
PROPOSED VERIZON WIRELESS FRP SHROUD ASSEMBLY (3 TOTAL).
EXISTING 29.15' BUILDING (TO REMAIN).
PROPOSED VERIZON WIRELESS 20KW DIESEL
GENERATOR.
PROPOSED VERIZON WIRELESS METER BASE.
PROPOSED VERIZON WIRELESS UTILITY H-FRAME.
PROPOSED VERIZON WIRELESS PDU/BATTERY CABINET (1 TOTAL).
PROPOSED VERIZON WIRELESS RADIO CABINET WITH
(3) PRE-INSTALLED RAYCAP OVP DEVICES (1 TOTAL).
4
5
6
9
11
12
14
16
19
20
21
22
23
24
25
26
27
28
TOP OF PROPOSED VERIZON
WIRELESS FRP ANTENNA SHROUD
30.00' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
28.25' AGL
4
TOP OF EXISTING ROOFTOP
18.00' AGL
PROPOSED
VERIZON WIRELESS
20'-9" FENCED
LEASE AREA
14
16
21
16
14
21
27
24
EXISTING NATURAL
GAS METER & PIPING 9
FINISH GRADE
0.0' AGL
FINISH GRADE
0.0' AGL
21
1
20
EXISTING
ELECTRICAL ROOM
TOP OF EXISTING
UPPER PARAPET
22.25' AGL
TOP OF EXISTING
LOWER PARAPET
20.5' AGL
4
5
12
5
12
PROPOSED
VERIZON WIRELESS 9'-0"
FENCED LEASE AREA
24
2028
27
TOP OF EXISTING BUILDING
29.15' AGL
TOP OF EXISTING UPPER PARAPET
22.25' AGL
TOP OF PROPOSED VERIZON
WIRELESS FRP ANTENNA SHROUD
30.00 AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
28.25' AGL
TOP OF PROPOSED VERIZON
WIRELESS FRP MICROWAVE CANISTER
28.50' AGL
RAD CENTER OF PROPOSED
VERIZON WIRELESS MICROWAVE
27.50' AGL
5
12
6
11
TOP OF EXISTING ROOFTOP
18.00' AGL
TOP OF EXISTING LOWER PARAPET
20.5' AGL
EXISTING (2) 2" CONDUIT
EXISTING (2) 2" CONDUIT
28
1
25
22
23
26
19
TOP OF PROPOSED VERIZON
WIRELESS FRP ANTENNA SHROUD
30.00' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
28.25' AGL