HomeMy WebLinkAboutMFP19000753.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP19000753 IVR Number: 19000753 Permit Informaon Permit Name:Comcast Cable Franchise Permit Address/Locaon :02/18/2019Application Date:1923059031Parcel Number:201 S 7TH ST Permit Type:03/04/2019Issue Date:Franchise Permit Work Class:03/03/2020Expiration Date:Minor Utility Job Number:JT#310620Franchise Type:Cable Description:Proof and place 96ct fiber in existing Comcast system 373 feet. Directional bore new 4" conduit 465 feet. Place 2 new vaults. Pull 96ct fiber in new 4" conduit 465'. Pothole all existing utilities. Restoration per City of Renton standards. PRE CONSTRUCTION MEETING REQUIRED APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Comcast Cable Communication Management & Comcast Cable B: (215) 665-1700Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Michael Cannon Cannon Construction Inc 406 Porter Way Milton, WA 98354-9638 B: (253) 922-2787 C: (253) 588-4034 Contractor Business License Number: BL.020838Construction Contractor: CANNOCI055CS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Comcast Cable Communications Management LLC JT#310620 CAR PROS RENTON Cody Shackett 253-864-4246 Owen_Shackett@comcast.com 201 S 7th St. RENTON WA 98057 Car Pros Proof and place 96ct fiber in existing Comcast system 373 feet. Directional bore new 4'' Conduit 465 feet. Place 2 new 24''X36'' Vaults. Pull 96ct fiber in new 4'' conduit 465' See plans and drawings for details. n n 465 Cannon Construction Inc. (Pat Gottbreht )360-888-3211 CANNOCI055CS BL.020838 2/15/2019 MFP19000753 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS Scott Warlick 2/18/2019 Holly Powers 3/4/2019 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION K. KITTRICK/ DEV. SERVICE, PLAN REVIEW A. HENNINGER/J. ILLIAN POLICE CLARK WILCOX FIRE DAVID PARGARS/STA. #13 Car Pros 7th Ave (JT#310620) Cannon Construction (Pat Gottbreht)360-688-4102 Cody Shackett 253-8664-4246 410 Valley Ave NW, Puyallup WA Owen_Shackett@comcast.com S 7th St.Rainer Ave S TBD TBD Reset FormPrint Form Pat Gottbreht 2-15-2019 MFP19000753 Scott Warlick 2/18/2019Monday - Friday 9:00am - 3:00pm NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). SKETCH I -- NORTH -- I See TCP's for details. ROWROWROWROWROW ROWROW ROW ROWROWROW ROWROWROWROWROWROWROWROWROWROWROW ROWROWROWROWROWROW ROW ROW ROW ROW ROW EOP EOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEO P EOPEOPEOPEOP EOPEOPEOPEOPSW 7TH ST SW 7TH ST SW 7TH ST SW 7TH ST SW 7TH ST 167 167 707 739 V RAINIER AVE RAINIER AVE HARDIE AVE SWHARDIE AVE SWWTW21-7 W20-5R W4-2R W 2 0 - 5 R W4- 2 R F A S W21-7 R2-1 W 2 1 - 7 PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT. BUFFER DATA LONGITUDINAL BUFFER SPACE = B 200 30SPEED (MPH) LENGTH (FEET) 25 155 305 35 40 250 425360 45 50 570495 55 60 730 70 645 65 WITH TMA TYPICAL PROTECTIVE VEHICLE TYPE (LBS) TYPICAL PROTECTIVE VEHICLE (WITH TMA) LOADED WEIGHT (FEET) STATIONARY OPERATION FLAT BED, ECT. 4 YARD DUMP TRUCK, SERVICE TRUCK,IN ACCORDANCE WITH MINIMUM WEIGHT 15,OOO LBS. (MAXIMUM WEIGHT SHALL BE MANUFACTURER RECOMMENDATION) 30 MIN. A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED. * SIGN SPACING = X (FEET) FREEWAYS & EXPRESSWAYS 55/70 MPH (OR AS PER MUTCD) 1500' + - 60/65 MPH 800' + -RURAL HIGHWAYS 45/55 MPH 500' + -RURAL ROADS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) ALL SPACING MAY BE ADJUSTED TO ACCOMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS. 35/40 MPH 350' + -RURAL ROADS & URBAN ARTERIALS 25/30 MPH 200' + - (2)RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25 MPH OR LESS 100' + - (2)URBAN STREETS (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. MINIMUM TAPER LENGTH IN FEET (L) (FEET) LANE WIDTH POSTED SPEED (MPH) 3025 35 40 45 50 55 60 7065 15010105 270205 500450 -550 -- 16511115 295225 550495 660605 -- 18012125 320245 600540 720660 840780 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25/30 20 40 TCP NOTES: 1.ALL WORK TO BE PREFORMED DURING DAYTIME HOURS UNLESS TRAFFIC VOLUMES OR MUNICIPALITY DICTATE OTHERWISE. 2.ALL SIGNS ARE 48"x48" BLACK ON FLUORESCENT ORANGE UNLESS OTHERWISE NOTED. 3.USE OF SPOTTER TO FACILITATE PEDESTRIAN ACCESS ON 4FT MIN SIDEWALK. STOP WORK AS NEEDED TO PROVIDE SAFE PASSAGE. 4.MAINTAIN LOCAL ACCESS TO BUSINESSES AND RESIDENTIAL PROPERTIES. ALL DRIVEWAY ACCESS SHALL REMAIN OPEN DURING DURATION OF WORK. 5.WORK ARE TO INCLUDE STAGING AREA. WORK HOURS 6AM-6PM MON-FRI CANNON CONSTRUCTION CONTACT Pat Gottbreht-360-888-3211 pgottbreht@cannonconstructioninc.com TRAFFIC CONTROL PLAN TEMPORARY SHORT TERM DURATION WORK ZONE FOR VAULT ACCESS REFERENCE PLAN SET N COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 TCP 1 3 2/14/19 KEC PG MFP19000753 ROWROWROW ROW ROW ROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW EOPEOPEOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEO P EOPEOP ROWROWROW ROWROWROWEOPEOPEOPEOP167 167 200 739 765 V RAINIER AVE HARDIE AVE SWWTFAS W21-7 W20-5R W4-2R W21-7 PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT. BUFFER DATA LONGITUDINAL BUFFER SPACE = B 200 30SPEED (MPH) LENGTH (FEET) 25 155 305 35 40 250 425360 45 50 570495 55 60 730 70 645 65 WITH TMA TYPICAL PROTECTIVE VEHICLE TYPE (LBS) TYPICAL PROTECTIVE VEHICLE (WITH TMA) LOADED WEIGHT (FEET) STATIONARY OPERATION FLAT BED, ECT. 4 YARD DUMP TRUCK, SERVICE TRUCK,IN ACCORDANCE WITH MINIMUM WEIGHT 15,OOO LBS. (MAXIMUM WEIGHT SHALL BE MANUFACTURER RECOMMENDATION) 30 MIN. A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED. * SIGN SPACING = X (FEET) FREEWAYS & EXPRESSWAYS 55/70 MPH (OR AS PER MUTCD) 1500' + - 60/65 MPH 800' + -RURAL HIGHWAYS 45/55 MPH 500' + -RURAL ROADS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) ALL SPACING MAY BE ADJUSTED TO ACCOMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS. 35/40 MPH 350' + -RURAL ROADS & URBAN ARTERIALS 25/30 MPH 200' + - (2)RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25 MPH OR LESS 100' + - (2)URBAN STREETS (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. MINIMUM TAPER LENGTH IN FEET (L) (FEET) LANE WIDTH POSTED SPEED (MPH) 3025 35 40 45 50 55 60 7065 15010105 270205 500450 -550 -- 16511115 295225 550495 660605 -- 18012125 320245 600540 720660 840780 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25/30 20 40 WORK HOURS 6AM-6PM MON-FRI CANNON CONSTRUCTION CONTACT Pat Gottbreht-360-888-3211 pgottbreht@cannonconstructioninc.com TRAFFIC CONTROL PLAN TEMPORARY SHORT TERM DURATION WORK ZONE FOR VAULT ACCESS REFERENCE PLAN SET NTCP NOTES: 1.ALL WORK TO BE PREFORMED DURING DAYTIME HOURS UNLESS TRAFFIC VOLUMES OR MUNICIPALITY DICTATE OTHERWISE. 2.ALL SIGNS ARE 48"x48" BLACK ON FLUORESCENT ORANGE UNLESS OTHERWISE NOTED. 3.USE OF SPOTTER TO FACILITATE PEDESTRIAN ACCESS ON 4FT MIN SIDEWALK. STOP WORK AS NEEDED TO PROVIDE SAFE PASSAGE. 4.MAINTAIN LOCAL ACCESS TO BUSINESSES AND RESIDENTIAL PROPERTIES. ALL DRIVEWAY ACCESS SHALL REMAIN OPEN DURING DURATION OF WORK. 5.WORK ARE TO INCLUDE STAGING AREA. R2-1 COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 TCP 2 3 2/14/19 KEC PG MFP19000753 ROW ROW ROW ROW ROW ROW ROWROWROWROWROW ROW ROW ROW ROWROWROW ROWROWROWROWROWROWROWROWROWROWROW ROWROWROWROWROWROW ROW ROW ROW ROW ROW ROW ROW ROW ROW EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEO P EOPEOPEOPEOP EOPEOPEOP EOP EOP EOP EOPEOPSW 7TH ST SW 7TH ST SW 7TH ST SW 7TH ST SW 7TH ST 167 167 739105 RAINIER AVE RAINIER AVE HARDIE AVE SWHARDIE AVE SWWTFAS W21-7 W20-5R W4-2R W21-7 W21-7 PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT. BUFFER DATA LONGITUDINAL BUFFER SPACE = B 200 30SPEED (MPH) LENGTH (FEET) 25 155 305 35 40 250 425360 45 50 570495 55 60 730 70 645 65 WITH TMA TYPICAL PROTECTIVE VEHICLE TYPE (LBS) TYPICAL PROTECTIVE VEHICLE (WITH TMA) LOADED WEIGHT (FEET) STATIONARY OPERATION FLAT BED, ECT. 4 YARD DUMP TRUCK, SERVICE TRUCK,IN ACCORDANCE WITH MINIMUM WEIGHT 15,OOO LBS. (MAXIMUM WEIGHT SHALL BE MANUFACTURER RECOMMENDATION) 30 MIN. A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED. * SIGN SPACING = X (FEET) FREEWAYS & EXPRESSWAYS 55/70 MPH (OR AS PER MUTCD) 1500' + - 60/65 MPH 800' + -RURAL HIGHWAYS 45/55 MPH 500' + -RURAL ROADS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) ALL SPACING MAY BE ADJUSTED TO ACCOMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS. 35/40 MPH 350' + -RURAL ROADS & URBAN ARTERIALS 25/30 MPH 200' + - (2)RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25 MPH OR LESS 100' + - (2)URBAN STREETS (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. MINIMUM TAPER LENGTH IN FEET (L) (FEET) LANE WIDTH POSTED SPEED (MPH) 3025 35 40 45 50 55 60 7065 15010105 270205 500450 -550 -- 16511115 295225 550495 660605 -- 18012125 320245 600540 720660 840780 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25/30 20 40 TCP NOTES: 1.ALL WORK TO BE PREFORMED DURING DAYTIME HOURS UNLESS TRAFFIC VOLUMES OR MUNICIPALITY DICTATE OTHERWISE. 2.ALL SIGNS ARE 48"x48" BLACK ON FLUORESCENT ORANGE UNLESS OTHERWISE NOTED. 3.USE OF SPOTTER TO FACILITATE PEDESTRIAN ACCESS ON 4FT MIN SIDEWALK. STOP WORK AS NEEDED TO PROVIDE SAFE PASSAGE. 4.MAINTAIN LOCAL ACCESS TO BUSINESSES AND RESIDENTIAL PROPERTIES. ALL DRIVEWAY ACCESS SHALL REMAIN OPEN DURING DURATION OF WORK. 5.WORK ARE TO INCLUDE STAGING AREA. WORK HOURS 6AM-6PM MON-FRI CANNON CONSTRUCTION CONTACT Pat Gottbreht-360-888-3211 pgottbreht@cannonconstructioninc.com TRAFFIC CONTROL PLAN TEMPORARY SHORT TERM DURATION WORK ZONE FOR NEW UNDERGROUND REFERENCE PLAN SET N R2-1 COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 TCP 3 3 2/14/19 KEC PG MFP19000753 WORK AREA THIS IS PROPRIETARY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED CANNON COMPANIES CONTACTS: PROJECT MAP: N CANNON Pat Gottbreht-253-888-3211 pgottbreht@cannonconstructioninc.com COMCAST Kyle Kinney-253-235-7016 Kyle_Kinney@cable.comcast.com Car Pros POC:______________________________________________ Review _________________________ Property Mgt:________________________________________ Review _________________________ 1 - COVER SHEET 2 -LINE TYPE AND SYMBOL LEGEND 3 -STANDARD DETAILS 4 -OVERVIEW 5-7 -DESIGN 8-10 -SITE PHOTOS 96 CT FIBER: 838 FT + 20% STORAGE = 1005 FT 12 CT FIBER: 288 FT + 20% STORAGE = 345 FT *ALL FOOTAGES AND MATERIALS ARE ESTIMATED SCOPE OF WORK: SHEET INDEX: BILL OF MATERIALS*: NEW AERIAL = OVERLASH = NEW UNDERGROUND = EXISTING UNDERGROUND = RISER (0)= TOTAL FOOTAGE = 0 FT. 0 FT. 465 FT. 373 FT. 0 FT. 838 FT. PROJECT DESCRIPTION - ROW* NEW BUILDING PATH WAY = EXISTING BUILDING PATH WAY = NEW UNDERGROUND = EXISTING UNDERGROUND = TOTAL FOOTAGE = 100 FT. 0 FT. 188 FT. 0 FT. 288 FT. PROJECT DESCRIPTION -SITE* TOTAL PROJECT FOOTAGE =1126 FT. -TIE INTO EXISTING CASE - SP.WAKV.0178 (KV07S.4A.1C.3A) -PROOF AND PLACE (1) 96CT FIBER IN EXISTING CONDUIT -INTERCEPT EXISTING CONDUIT AND PLACE NEW 24"X36" VAULT -DIRECTIONAL BORE AND INSTALL (1) 4" CONDUIT AND PULL (1) 96CT FIBER THROUGH. -INSTALL NEW 24"x36" VAULT AT EDGE OF RIGHT OF WAY. -DIRECTIONAL BORE ON PRIVATE PROPERTY AND INSTALL (1) 4" CONDUIT AND PULL (1) 12CT FIBER THROUGH. -PLACE NEW 1-1/4" INNER DUCT & PULL (1) 36CT FIBER THROUGH EMPTY DUCT. CANNON COMPANIES SAFETY | QUALITY | INTEGRITY | TEAMWORK 201 S 7TH ST RENTON, WA 98057 CAR PROS JT# 310620COMCAST MFP19000753 EOP FL P C S D G W TS T ST UT ROW DD DD DD DD EDGE OF PAVEMENT FOGLINE POWER COMMUNICATION SEWER DRAIN DRAINAGE DITCH GAS WATER TRAFFIC SIGNAL TELCOM STEAM UNKNOWN UTILITY RIGHT OF WAY TRAFFIC CONES PROPOSED NEW CONDUIT STRAW WATTLES P V LT CW R UTILITY POLE VAULT - SMALL PEDESTAL STREET LIGHT CROSSWALK LIGHT UTILITY RISER V VAULT - SMALL 444LA MANHOLE VAULT - 25TA CB CB CATCH BASIN CATCH BASIN WITH SOCK GLULAM UTILITY POLECENTER LINE LANE LINE FENCE HIGH VISIBILITY FENCE S SEWER MANHOLE D DRAIN MANHOLE W WATER MANHOLE V UTILITY VALVE SHRUBBERY BORE PIT VAULT - LARGE VAULT - 25TA C COMMUNICATION MANHOLE FIRE HYDRANT DISTANCE STATIONSTA 0+00 NOTE CALLOUT# X.X DISTANCE DIMENSION ASPHALT SURFACE CONCRETE SIDEWALK PANEL CONCRETE ROADWAY PANEL HF H-FRAME VAULT - LARGE CAB CABINET LEGEND LANE DIRECTION INDICATOR PROPOSED MARK-UP NOTATIONS RESTORATION TYPESEXISTING FEATURESLINE TYPES COMCASTCOMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 LEGEND 2 10 2/14/19 KEC PG MFP19000753 TRENCH - HARD SURFACE STANDARD DETAIL# TRENCH - SOFT SURFACE STANDARD DETAIL# COMCASTCOMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 STANDARD DETAILS 3 10 2/14/19 KEC PG MFP19000753 V V V V 96ct 96ct 96ct PROOF AND PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT PROPOSED DIRECTIONAL BORE. INSTALL (1) 4" CONDUIT AND PULL (1) 96CT FIBER THROUGH. SEE SHEETS 6-7 FOR DETAILED PLAN VIEWS. PROPOSED NEW VAULT. INTERCEPT EXISTING CONDUIT AND OVERSET NEW 24"x36" VAULT. SEE SHEETS 6-7 FOR DETAILED PLAN VIEWS. PROPOSED NEW VAULT. INSTALL NEW 24"x36" VAULT. SEE SHEETS 6-7 FOR DETAILED PLAN VIEWS. INSTALL NEW SPLICE CASE IN NEW VAULT 12ct PROPOSED DIRECTIONAL BORE. INSTALL (1) 4" CONDUIT AND PULL (1) 12CT FIBER THROUGH. 147'226'465'188'TIE INTO EXISTING SPLICE CASE SP.WAKV.0178 (KV07S.4A.1C.3A) 75'25' PROPOSED NEW EMT. INSTALL 2" EMT TO OUTSIDE OF BUILDING AND INSTALL NEW LOCK BOX. OFFICE SPACE (SECOND FLOOR) SERVER ROOM (SECOND FLOOR) PROPOSED NEW INNERDUCT. INSTALL 1-1/4" INNERDUCT IN FALSE CEILING AND PULL (1) 12CT FIBER THROUGH. EXTENSIVE INSULATION ABOVE FALSE CEILING. TAKE CARE WHEN REMOVING AND INSTALL INNERDUCT.N COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 OVERVIEW 4 10 2/14/19 KEC PG MFP19000753 ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROWRO W ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROWROWROW ROWROWROWROWROWROWROWROW ROW ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROWROWROWROWROWROW ROW ROW ROW ROW ROW ROW ROW ROW ROWROWROWROWROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROWROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOPEOPEOP EOP EOPEOP EOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOP EOPEOPEOP EOP EOP EOP EOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOP EO P EOP EOPEOPEOPEOPEOPEOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO P EOP EOP EOP EOP EOP EOP EOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPSW 7TH ST SW 7TH ST SW 7TH ST SW 7TH ST SW 7TH ST 167 167 750 720 710 201 650 707 739105 V VV V 147' PROOF AND PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT PROPOSED DIRECTIONAL BORE. INSTALL (1) 4" CONDUIT AND PULL (1) 96CT FIBER THROUGH. SEE SHEETS 6-7 FOR DETAILED PLAN VIEWS. PROPOSED NEW VAULT. INTERCEPT EXISTING CONDUIT AND OVERSET NEW 24"x36" VAULT. SEE SHEETS 6-7 FOR DETAILED PLAN VIEWS. PROPOSED NEW VAULT. INSTALL NEW 24"x36" VAULT. SEE SHEETS 6-7 FOR DETAILED PLAN VIEWS.INSTALL NEW SPLICE CASE IN NEW VAULT TIE INTO EXISTING SPLICE CASE SP.WAKV.0178 (KV07S.4A.1C.3A)226'465'188'75'25' PROPOSED NEW EMT. INSTALL 2" EMT TO OUTSIDE OF BUILDING AND INSTALL NEW LOCK BOX. OFFICE SPACE (SECOND FLOOR) SERVER ROOM (SECOND FLOOR) PROPOSED NEW INNERDUCT. INSTALL 1-1/4" INNERDUCT IN FALSE CEILING AND PULL (1) 12CT FIBER THROUGH. N COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 DESIGN 5 10 2/14/19 KEC PG MFP19000753 720 EOPEOPEOP EOPEOP EOPEOP EOP EOP EOP EOP EOP EOP EOP EOP DDDDDDD DD D DD D D D WWW WW W W W W W W W W W W W GGGGGGGGGGGGGGG CCCCBDDDDDDCB CBCB SLSLVSL VCOMCASTD D W W V M MWWV SL VSLPOWERVAULT CB F H W DDC M W CBG G G G G G G G V DRIVEWAY SIDEWALK LANDSCAPEEOPEOP EOP EOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP ROW ROW ROWROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROWROW ROW ROW ROW ROW ROW ROW V BO R E P I TLANDSCAPE LANDSCA PE RAINIER AVE SS T A 1 3 + 0 0 S T A 1 3 + 5 0 S T A 1 4 + 0 0 STA 14+50STA 15+29 ST A 1 5 + 0 0 STA 1 5 + 5 0 DRIVE WAY SIDEWALK 450' PROPOSE D DI RE CTI O NAL B ORE 5 RESTORATION NOTES: RESTORE ASPHALT AREA PER CITY OF RENTON SPECIFICATIONS. REMOVE AND REPLACE CONCRETE SIDEWALK PANEL PER CITY OF RENTON SPECIFICATIONS. 1 3 35' 46' 9' T R E N C H 4 32' 5' 5' 5' 710 SIDEWALKLANDSCAPEDRIVE WAY STATION START STATIONING STARTS AT 10+00 AT THE INTERSECTION OF S 7TH ST & RAINIER AVE S UTILITY DISCLAIMER ALL LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. LOCATION OF ALL UTILITIES TO BE VERIFIED PRIOR TO CONSTRUCTION. CALL UTILITY UNDERGROUND LOCATION CENTER AT 1-800-424-5555 POTHOLE DISCLAIMER POTHOLE IS SOFT SURFACES WHEN AVAILABLE. PATCH POTHOLE LOCATION PER LOCAL JURISDICTION SPECIFICATION LOCATION 1 CONSTRUCTION NOTES: PROOF AND PULL (1) 96CT FIBER THROUGH EIXSTING CONDUIT. PROPOSED NEW VAULT. LOCATE AND INTERCEPT EXISTING CONDUIT AND OVERSET NEW 24"x36" VAULT IN ASPHALT AREA PER DETAIL ON SHEET 3. PULL (1) 96CT FIBER CABLE THROUGH. PROPOSED TRENCH IN CONCRETE SIDEWALK. INSTALL (1) 4"Ø CONDUIT AND PULL (1) 96CT FIBER THROUGH. PROPOSED DIRECTIONAL BORE UNDER CONCRETE SIDEWALK AND INSTALL (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. 2 6 12' 8' 5 2 5'4' 3 4 6 SCALE: 1"=20' 0'10'20'40' CSWPP LEGEND STRAW WATTLES HIGH VIABILITY FENCE CB NATIVE TRENCH MATERIAL SHALL BE COVER WITH PROTECTIVE TARP AND SECURED WITH SANDBAGS TO PREVENT RAIN WATER ABSORPTION. CATCH BASIN WITH SOCK N COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 DESIGN 6 10 2/14/19 KEC PG MFP19000753 710 SW 7TH ST EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP D D D DD D DDD D D DDD W W W W W W W W W W W W W W W W W GG G G G G G GG G G GG G G CB CBD SLVSLSL VSLFHV COM VAULTSLVSL D D D D DC DC D D D DWW DCEOPEOPEOPEOPEOPEOP EOP EOP EOPEOPEOPE O P EOP EOPEOPEOP ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROWROWR O W ROW ROWROW BORE P I T V PROP O S E D LANDSC APE LANDS CAPE RAINIER AVE SS T A 1 0 + 5 0 S T A 1 1 + 0 0 S T A 1 1 + 5 0 S T A 1 2 + 0 0 S T A 1 2 + 5 0 DRIVEW A Y SIDEWALK SIDEWALK STATION START STATIONING STARTS AT 10+00 AT THE INTERSECTION OF S 7TH ST & RAINIER AVE S UTILITY DISCLAIMER ALL LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. LOCATION OF ALL UTILITIES TO BE VERIFIED PRIOR TO CONSTRUCTION. CALL UTILITY UNDERGROUND LOCATION CENTER AT 1-800-424-5555 POTHOLE DISCLAIMER POTHOLE IS SOFT SURFACES WHEN AVAILABLE. PATCH POTHOLE LOCATION PER LOCAL JURISDICTION SPECIFICATION LOCATION CSWPP LEGEND STRAW WATTLES HIGH VIABILITY FENCE CB NATIVE TRENCH MATERIAL SHALL BE COVER WITH PROTECTIVE TARP AND SECURED WITH SANDBAGS TO PREVENT RAIN WATER ABSORPTION. CATCH BASIN WITH SOCK 1 2 6' TRENCH 56' 62' 3 PROP OS ED DIR ECTI ON AL B O RE 37' 37' 5' 201SIDEWALK1 CONSTRUCTION NOTES: PROPOSED DIRECTIONAL BORE UNDER CONCRETE SIDEWALK AND INSTALL (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. PROPOSED TRENCH IN LANDSCAPE AREA. INSTALL (1) 4"Ø CONDUIT AND PULL (1) 96CT FIBER THROUGH. PROPOSED NEW VAULT. INSTALL NEW 24"x36" VAULT IN LANDSCAPE AREA AT EDGE OF RIGHT OF WAY PER DETAIL ON SHEET 3. PULL (1) 96CT FIBER CABLE THROUGH. 2 3 STRAW WATTLES G G G G G G G G G G G G G G G G V SCALE: 1"=20' 0'10'20'40' LAND S C A P E N COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 DESIGN 7 10 2/14/19 KEC PG MFP19000753 5 NO SCALE EXISTING CONDUIT INTERCEPT 6 NO SCALE NEW CONDUIT IN ROW 7 NO SCALE NEW CONDUIT IN ROW 3 NO SCALE EXISTING CONDUIT 4 NO SCALE EXISTING CONDUIT1NO SCALE TIE-IN CASE EXISTING VAULT2NO SCALE TIE INTO EXISTING SPLICE CASE SP.WAKV.0178 (KV07S.4A.1C.3A) PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT TRENCH/ DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. INTERCEPT EXISTING CONDUIT AND OVERSET NEW 24"x36" VAULT PULL (1) 96CT FIBER THROUGH EXISTING VAULT PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 SITE PHOTOS 8 10 2/14/19 KEC PG MFP19000753 NEW 24"x36" VAULT11NO SCALE 12 NO SCALE 13 NO SCALE 10 NO SCALE NEW CONDUIT ON PRIVATE NEW CONDUIT ON PRIVATE NEW CONDUIT IN ROWNEW CONDUIT IN ROW9NO SCALE8NO SCALE NEW CONDUIT IN ROW DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. TRENCH/ DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 96CT FIBER THROUGH. INSTALL NEW 24"x36" VAULT. INSTALL NEW SPLICE CASE EXIT RIGHT OF WAY.DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 12CT FIBER THROUGH. DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 12CT FIBER THROUGH.DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 12CT FIBER THROUGH. COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 SITE PHOTOS 9 10 2/14/19 KEC PG MFP19000753 BUILDING TRANSITION14NO SCALE NEW 1-1/4" INNERDUCT15NO SCALE NEW 1-1/4" INNERDUCT16NO SCALE NEW 1-1/4" INNERDUCT17NO SCALE NEW 1-1/4" INNERDUCT18NO SCALE SERVER ROOM19NO SCALE SERVER RACK20NO SCALE DIRECTIONAL BORE (1) 4"Ø CONDUIT. PULL (1) 12CT FIBER THROUGH. 2" CORE INTO BUILDING IN DROP CEILING INSTALL NEW LOCK BOX ON SIDE OF BUILDING 2" CORE INTO BUILDING IN DROP CEILING INSTALL 2" EMT. PULL (1) 12CT FIBER THROUGH INSTALL 1-1/4" INNERDUCT IN FALSE CEILING AND PULL (1) 12CT FIBER THROUGH. INSTALL 1-1/4" INNERDUCT IN FALSE CEILING AND PULL (1) 12CT FIBER THROUGH. INSTALL 1-1/4" INNERDUCT IN FALSE CEILING AND PULL (1) 12CT FIBER THROUGH. INSTALL 1-1/4" INNERDUCT IN FALSE CEILING AND PULL (1) 12CT FIBER THROUGH.INSTALL 1-1/4" INNERDUCT IN FALSE CEILING AND DOWN TO RACK PULL (1) 12CT FIBER THROUGH. INSTALL NEW TERM PANEL AND SWITCH ON EXISTING RACK. COMCAST OF DATE REVISION BY QC CANNON COMPANIES 310620CAR PROS 201 S 7TH ST RENTON, WA 98057 SITE PHOTOS 10 10 2/14/19 KEC PG MFP19000753