Loading...
HomeMy WebLinkAboutR-394411SE 1/4 , SECTION 26, TOWNSHIP 23N, RANGE 4 E, W.M. ASPH GRADINGAl.ND PAVING PLAN �21 / ASPH � I CONC CURB ~�F7 CONC CURB �,r� � � PLANTER Y PLANTER o J 0 b 3 � PROPERTY LINE -24J�Q NH(� ° i w ° PI ANTFR S01'14 07 W 459.00 � m IcT� W a o CONC CURB z PLANTER DEA 3011 >" �1,4GAAlD-USkIER_------ - ---- - z ,i 0 N: 175088.99 - E: 1294329.94 LLI�, W X EL: 19.78 o X.-R.Qo20.5f X I W o �� TC/0.99TC 20.77 C 20.89 \\ ASPH coNc �o r74 MATCH EX \ U z TC 20.92 ��' BC 20.49 BC 20.27 ate°, C 20.39 cuRe Q W 20.6f BC 20.42��oN E 0.3� TC 20.94 20.4t TC=BC 20.39 w a" MATCH EX BC 200.4 X MATCH EX 1•09° E TC=BC 20.74 " �' a P I o s°9 / P ' ' TC 2 40 I a �F-I' TC 21.92 Q P I m 7.5' UTILITY • . • • TC 20.55 BC 21.37 do ° ° Q I EASEMENT ,��' i' •� BC 20'90 PER PLAT OF " ' ' TC 20.84 BC 20.05 J � .�� a o TC=BC 20.90 _ BC 20.34 1.3% 0.7% TC 21.85 �19 WASHINGTON TECHNICAL CENTER -y a LQL I II VOL. 122, PAGES rn rrj j° BC 2g1�.35 98-102 20' 2N J 4.3% / P P- Q SE TBACK • ' TC 2) 70 { z I PER SHORT I TC=BC 20.61' PLAT N0. BC 20.20 FF 21.�5 °TC 21.11 BC 20.61 w 19?J .8% a D TC 21.03 MATCH EX ° OC � \ 3 TC 21.98 � ^ gT ��: AND WA'�. BC 20.53 C 20.30 BC 21.15 `� v: 1 .74 TC 21.00 � BC 19.80 � 4•5%° ° `-- v TC 21.96 ° ° =: 129425 • BC 20.50(MATCH w , °° -1 . 1)n �O N01'14'07 E 60„ TC 20.95 z PROPERTY LINE F UND 8" ROL) A 8y TC 20.92 � 'AP-*o'�� 20.45 � TC 21.95 BC 21.13 RI 20.25 O MATCH EX ' 0 FOUND 1/ " Ruin nrlq CAP I cv BC 21.12 TC 21.52 \ �° BC 20.42(MATCH EX U 1o'x2o' LS # 1373 20.00f =� 21.33 BC 21.02 2 '20'�• 1,,-BC 20.52 MATCH EX (D PARKING STALL MATCH EX BLDG FF: 21.50 / I ( ) PLANTER z EASEMENT AS 98f TC 1.4 1 0% 21.38 ° PER REC. NO. Y 9006260973 M TCH EX H 99 FF 21.50E 21.50 2.0% o coNTC 2MATCH`� 19. 1f zQ MATPH EX � \ 2, 0.5� H -` 0 a I- CB CP a z RIM=19.94 ° • ' �'' , IE=17.4 10" ONC W i IE=17.5 10" ONC SE Q TC�J 59 >, y m EX BC:20.09 B1 5 FF 21.50 r) o rq u' m z m 20 RIM=19.81 Q N �o-10 _ aS�A IE=16.5 10� N� EXISTING BLDG FF: 21.50 n-� 1 X `,IE=16.6 10 CPP SE o, 0 Pt� N0. z N c> Z p o N P►-AT_Sg KING COUNTY-FMD FACILITIES GM 7o _' j0 � 1 p16 1 900 OAKESDALE AVE SW 98055 � o Q �o 0 o-�v m� 1 3 STORY BUILDING Z rr 1 0 Zoom i T y Z 9188000146 Z% cP 00 CD mnw u1ri 1 PSP&L EASEMENT FOR ELECTRIC TRANSMISSION AND/OR DISTRIBUTION SYSTEM REC. NO. 89062604 o C 1 OVER A PORTION OF LOT 2, CITY OF RENTON LOT 1 9100014 ?^to ADJUSTMENT NO. 001-86, REC. NO. 8609179004 (A ...AS CONSTRUCTED. OR TO BE CONSTRUCTED. LEGEND - EXISTING CONTROL POINT (AS NOTED) BUILDING LINE • REBAR (FOUND AS NOTED) 1VCABLE TV UNDER m GROUND LINE WHEEL CHAIR RAMP a FIBER OPTIC z SIGN UNDERGROUND LINE 0 CDI LIGHT GAS UNDERGROUND o LINE m HANDICAP PARKING O 0 POWER UNDERGROUND w STORM CATCH BASIN LINE U N co STORM CLEANOUT STORM DRAIN w LINE a ) STORM CULVERT o WATER LINE FC1 CABLE TV PULLBOX ® GAS VALVE 0 ® GAS METER m ® WATER VALVE E 0 FIRE HYDRANT 8 KEY/CARD PAD X 0 DECIDUOUS TREE m CONIFEROUS TREE Q z J LL 301 251 20 151 21 0 0 (MATCH 20.9f MATCH EX 20.9f MATCH EX \ GRASS 15' PUBLIC UTILITIES EASEMENT INCLUDING WATER / w AND SEWER AS PER REC. NO. 901206/027 ,, , µw I w / RIM=19.45 ,_1b IE=17.2 10" CPP SW O IE=17.7 4" PVC N ASPH CONC WALK f=`� CB RIM=19.15 IE=17.0 10" CPP NE / IE=16.9 12" CPP SW IN PROPOSED BUILDING: I I 6" CONCRETE 4" CRUSHED SURFACING I TOP COURSE I I FINISHED GRADE FINISHED GRADE - -- ------ -- -- - - -- - --- 4" HOT EX ASPHALT MIX � PAVEMENTUT 5.91 CONCRETEJ L 6" CRUSHED WALKWAY SURFACING ---------------------------------1------------------------ ------------------ TOP COURSE STRUCTURAL FILL AS NEEDED. MINIMUM THICKNESS 6", SEE EXISTING GRADE SEE SUBBASE AND SITE SUBBASE AND SITE PREPARATION PREPARATION NOTES. NOTE 6. � ASPHALT PAVEMENT AND SUBGRADE DETAILS 30 25 20 15 7.50' NATUF EASEti I cc 0 10 20 40 LEGEND - PROPOSED PROPOSED TYPE AND TYPE -2 CATCH BASIN O■ PROPOSED STORM DRAIN MANHOLE PROPOSED WATER QUALITY STRUCTURE SD PROPOSED STORM DRAIN ASPHALT PAVEMENT LANDSCAPE ° o a CONCRETE WALK - - - - LIMITS OF DISTURBANCE CHAINLINK FENCE PROPOSED GAS SERVICE 13 PROPOSED GAS METER O O O 00 �, N co O O 0 T Q J r 18 Pl.KM PROPOSED GAS VALVE co co I -19- O CONC CURB I O o CB IM17.11 110 E" CPP W SUBGRADE & SITE PREPARATION NOTES T IE=17.2 10" CPP E PER GEOTECHNICAL ENGINEERING REPORT PREPARED BY S&EE, DATED 3/7/2017 W GRASS 3 1. ALL LOOSE AND SILTY MATERIALS SHOULD BE REMOVED FROM SUBGRADE co PRIOR TO PLACEMENT OF BEDDING MATERIAL IF SOFT SILTY SOILS ARE "♦ o z ENCOUNTERED, IT MAY BE REQUIRED TO LAY DOWN A 12 TO 18 INCHES THICK 0 LAYER OF QUARRY SPALLS AND INSTALL A LAYER OF 4 TO 6 INCHES THICK Q ° CLEAN CRUSHED ROCK (1-1/4-) ON TOP. 2. AREAS OF PROPOSED BUILDING AND PAVEMENT BE STRIPPED OF ASPHALT. fn zB I ALL EXISTING UNDERGROUND UTILITIES SHOULD ALSO BE REMOVED. AFTER ° STRIPPING AND EXCAVATION, SUBGRADES OFSLABS, PAVEMENT, OR AREAS TO RECEIVE NEW FILL SHOULD BE THOROUGHLY PROOF -ROLLED USING HEAVY F CONSTRUCTION EQUIPMENT. T O 3. IF THE SUBGRADE IS WET AND PROOF ROLLING IS NOTFEASIBLE, THE AREA c') SHOULD BE PROBED USING A STEEL BAR SO AS TO AVOID DISTURBANCE AND (� ° RUTTING OF THE SUBGRADE SOILS. AREAS WHICH ARE FOUND TO BE LOOSE ;PH '_-20 - _ _ ' " OR SOFT, OR WHICH CONTAIN ORGANIC SOILS SHOULD BE OVER -EXCAVATED. IT IS OUR EXPERIENCE THAT VERY SOFT SUBGRADE CAN BE STABILIZED WITH CV �o 2 FEET OF OVER -EXCAVATION AND BACKFILL WITH STRUCTURAL FILL OVER A N 0 LAYER OF GEOTEXTILE. - 120 \ 4. THE OWNER'S TECHNICAL REPRESENTATIVE WILL OBSERVE THE PROOF -ROLLING I ' ^ �o AND/OR PERFORM PROBING TO ASSIST IN EVALUATING THE OVER -EXCAVATION V J AND BACKFILL REQUIREMENTS. 5. AFTER STRIPPING, OVER -EXCAVATION AND EXCAVATION TO THE DESIGN GRADE, THE TOP 12 INCHES OF THE SUBGRADE SOIL SHOULD BE MOISTURE -CONDITIONED TO +/-2% FROM IT OPTIMUM MOISTURE CONTENT SEE SHEET L1.2 FOR LANDSCAPE SECTIONS AND THEN RE -COMPACTED TO A FIRM AND NON -YIELDING CONDITION OR AT LEAST 95% OF THEIR MAXIMUM DRY DENSITY AS DETERMINED USING ASTM D-1557 TEST PROCEDURES (MODIFIED PROCTOR TEST). SEE STRUCTURAL FOR SLAB-ON-GADE 6. STRUCTURAL FILL SHOULD BE FREE OF ORGANIC AND FROZEN MATERIAL AND AND SUBBASE DETAILS UNDER THE BUILDING SHOULD CONSIST OF HARD DURABLE PARTICLES, SUCH AS SAND, GRAVEL, OR QUARRY -PROCESSED STONE. THE ONSITE GRANULAR FILL SOILS ABOVE THE DEPTH OF 5 FEET ARE SUITABLE ON A SELECT BASIS. THE NATIVE SOILS BELOW ARE SILTY IN NATURE AND SHOULD NOT BE USED. SUITABLE IMPORTED STRUCTURAL FILL MATERIALS INCLUDE SILTY SAND, SAND, MIXTURE OF SAND AND GRAVEL, RECYCLED CONCRETE, AND CRUSHED ROCK. ALL STRUCTURAL FILL MATERIALS SHALL BE APPROVED BY THE OWNER'S TECHNICAL REPRESENTATIVE PRIOR TO USE. SOIL TYPE NOTE PER GEOTECHNICAL ENGINEERING REPORT PREPARED BY S&EE, DATED 3/7/2017, THE FIRST 5 TO 6 FEET BELOW EXISTING GRADE IS ANTICIPATED TO BE FILL WITH LOOSE TO MEDIUM DENSE, SAND, SILTY SAND AND SILT. IF OTHER CONDITIONS ARE ENCOUNTERED, CONTACT THE GEOTECHNICAL ENGINEER OF RECORD. SCALE: 1 " = 10"(H) - 1 " = 5' (V) SURVEYED: SCALE: AALA HORIZONTAL: NAD 19 3/1991 DESIGNED: AS NOTED GXLE DAWN` SGR ONE INCH DATUM CHECKED: AGC AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED:AGC SCALE ACCORDINGLY DISTURBED AREA: 17,879 SQUARE FEET (0.41 ACRES) 111111 17 - ll•IB CITY OF RENTON Planning/Building/Public Works Dept z GPI\ BEFORE YIii OG�c CALL BEFORE YOU DIG W U i Call: TOLL FREE Q W 1-800-424-5555 uJ Q J IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 a DEVELOPMENT ENGINEERING J rnair 11/30/2018 01 z o a ® ODAVID EVANS ANDASSOCIATES INC. 14432 SE Eastgate Way, Suite 400 Bellevue Washington 98007 0 W KING COUNTY REGIONAL DATE. 1/3/2018 z AFIS LAB REPLACEMENT FIELDBOOK: PAGE: O DRAWING NO: U GRADING AND PAVING PLAN C6.0 CD z SHEET: OF: 12 135 Y R-39941 1