HomeMy WebLinkAboutR-394419SE 1/4 ,SECTION 26, TOWNSHIP 23N, RANGE 4 E, W.M.
IRRIGATION PLAN
M
0
w
I—
z
w
2
LU
Q
w
Ir
Q
J
U)
LL
J
z
O
0
LU
F_
D
0
z
V
a
J
n
O
Q
rr
_ N _I ch a. t0
m 0:O
TFF
as
I
o= Q�
�o
co
I
�M I ,�Q12
0 Ln of :t I —
N I 7.5' UTILITY i F� ❑ ❑
I EASEMENT
PER PLAT OF i
WASHING N i 13 i
TECHNICAL C I I
I I VOL. 122, G Fv
20'98-102 I
_B ILDING I
S TBACK 13 �
I PE SHORT I l 1
r—
PL16 80•
14 1 \
� 1
� 1 3
N01°1407"E 60 0' 1
PRO ERTY LI E ` 1 7.3 /
1 1"
10'X20'
DARKING STALL 12 t I
EASEMENT AS • 0 1 i
PER REC. NO.
9006260973 1
1 i
1 1
— 1F
0
1
1 �
1
U,
-0 0- n _ gU1�DING 1
rl
y o n PE Nso.
n N '0
1 P0�6'aa 1
�� 1Ado ��0
m to c� o "°rn
1 Z 1
00m
0 1
ca o 1
� 9
0) r_ 1
o m(5)
91 8000145 �' 1
m
v
'0-a�m�l
0�,oZ�l
O �ZN
1 O
14
0
womm
1"
_T-T�"clo
N
13
13
13
7:�
0'
0
D13 0
0
9188000146
13
PSP&L EASEMENT FOR ELECTRIC TRANSMISSION
AND/OR DISTRIBUTION SYSTEM REC. NO. 8906260460
OVER A PORTION OF LOT 2, CITY OF RENTON LOT LINE
ADJUSTMENT NO. 001-86, REC. NO. 8609179004
...AS CONSTRUCTED, OR TO BE CONSTRUCTED,
EXTENDED OR RELOCATED.
13 Nv//
0
1
I
12
l�
� 15' PUBI
AND SEA
12 I WV
0
No
0 10 20 40
SURVEYED: n n I n
DESIGNED: JCGA
DRAWN` G B K
CHECKED: JCGA
NO. REVISION BY DATE APPR I APPROVED:JCGA
IRRIGATION EQUIPMENT LEGEND
® TORO DRIP CONTROL ZONE KIT DZK-TPV-1-MF
H BALL VALVE - PVC NIBCO #4660, SIZE TO MATCH LINE
Fv TORO DL2000 AUTOMATIC FLUSH VALVE (INSTALL AT LOW POINT EACH DRIP ZONE)
- EXISTING IRRIGATION CONTROLLER (SEE GENERAL NOTE 15)
Q RAINBIRD QUICK COUPLING VALVE #44LRC
X❑ TORO DL-MP9 DRIP SYSTEM OPERATING INDICATOR
® TORO DL2000 AIR/VACUUM RELIEF VALVE (INSTALL AT HIGH POINT
EACH DRIP ZONE)
��rTTTT 0.66 O.D. NETAFIM TECHLINE CV DRIPLINE (0.6 GPH EMITTERS AT 18"
I I 111�J O.C.). STAKE DRIPLINE AT 2' O.C.
SCHEDULE 40 PVC MAINLINE
(SIZED AT 1.0" UNLESS SHOWN OTHERWISE ON PLANS)
SCHEDULE 40 PVC LATERAL
(3/4" SIZE UNLESS SHOWN OTHERWISE ON PLANS)
SCHEDULE 40 PVC SLEEVES
(SIZED AT DOUBLE WORKING PIPES) DIAMETER)
VALVE LEGEND
1 STATION NUMBER
1 " VALVE SIZE
5 7 GALLONS PER MINUTE
IRRIGATION GENERAL NOTES:
1. SEE IRRIGATION DETAILS, SHEET 22
2. THE IRRIGATION PLAN IS DIAGRAMMATIC. INSTALL MAINLINE, VALVES, PIPES, AND
ASSOCIATED EQUIPMENT IN PLANTING BEDS
IRRIGATION CONSTRUCTION NOTES:
11 P.O.C. FOR IRRIGATION IS STUB -IN TO EXISTING IRRIGATION MAINLINE. CONFIRM LOCATION
AND SIZE OF EXISTING IRRIGATION MAINLINE. FIELD -ADJUST P.O.C. AS NEEDED
12 SLEEVE UNDER PAVEMENT
13 EMITTER -IN -LINE DRIP TUBING SPACED @ 2' O.C. (TYP)
14 FIELD -ADJUST DRIPLINE AROUND EXISTING TREE TO REMAIN AS NEEDED
15 EXISTING IRRIGATION CONTROLLER IN JANITORS CLOSET, 1ST FLOOR. EXTEND IRRIGATION
CONTROL WIRE FROM NEAREST ZONE VALVE OF EXISTING IRRIGATION SYSTEM IN WIRE
SLEEVE CONDUIT
LEGEND:
0 "``�����
EXISTING TREES TO
REMAIN
PROJECT LIMITS
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL* NAVD 1988
HORIZONTAL* NAD 1983/1991
DATU M
E
•
CITY OF
RENTON
■
Planning/Building/Public Works Dept.
0
O
O
0
T
0�
O
O
O
T
J
rw
V )00
Cfl
0
QO
O
CALL BEFORE YOU DIGI
Call: TOLL FREE
-800-424-5555 1
z
2
w
U
J
w
m
Q
J
IN COMPLIANCE WITH CITY OF RENTON STANDARDS W
ILL.
10 PLANNING DIVISION Q
APPROVED
11/29/2018 jding Q
� Q
® 0 DAVID EVANS
ANDASSOCIATES INC.
14432 SE Eastgate Way, Suite 400
Bellevue Washington 98007
KING COUNTY REGIONAL
AFIS LAB REPLACEMENT
IRRIGATION PLAN
•
R
n
Ti
DATE:
I-
01-16-18
z
D
FIELDBOOK:
PAGE:
/O
U
DRAWING NO:
L1.1
Z
SHEET: OF:
20
135
Y
R-399419