Loading...
HomeMy WebLinkAboutR-394419SE 1/4 ,SECTION 26, TOWNSHIP 23N, RANGE 4 E, W.M. IRRIGATION PLAN M 0 w I— z w 2 LU Q w Ir Q J U) LL J z O 0 LU F_ D 0 z V a J n O Q rr _ N _I ch a. t0 m 0:O TFF as I o= Q� �o co I �M I ,�Q12 0 Ln of :t I — N I 7.5' UTILITY i F� ❑ ❑ I EASEMENT PER PLAT OF i WASHING N i 13 i TECHNICAL C I I I I VOL. 122, G Fv 20'98-102 I _B ILDING I S TBACK 13 � I PE SHORT I l 1 r— PL16 80• 14 1 \ � 1 � 1 3 N01°1407"E 60 0' 1 PRO ERTY LI E ` 1 7.3 / 1 1" 10'X20' DARKING STALL 12 t I EASEMENT AS • 0 1 i PER REC. NO. 9006260973 1 1 i 1 1 — 1F 0 1 1 � 1 U, -0 0- n _ gU1�DING 1 rl y o n PE Nso. n N '0 1 P0�6'aa 1 �� 1Ado ��0 m to c� o "°rn 1 Z 1 00m 0 1 ca o 1 � 9 0) r_ 1 o m(5) 91 8000145 �' 1 m v '0-a�m�l 0�,oZ�l O �ZN 1 O 14 0 womm 1" _T-T�"clo N 13 13 13 7:� 0' 0 D13 0 0 9188000146 13 PSP&L EASEMENT FOR ELECTRIC TRANSMISSION AND/OR DISTRIBUTION SYSTEM REC. NO. 8906260460 OVER A PORTION OF LOT 2, CITY OF RENTON LOT LINE ADJUSTMENT NO. 001-86, REC. NO. 8609179004 ...AS CONSTRUCTED, OR TO BE CONSTRUCTED, EXTENDED OR RELOCATED. 13 Nv// 0 1 I 12 l� � 15' PUBI AND SEA 12 I WV 0 No 0 10 20 40 SURVEYED: n n I n DESIGNED: JCGA DRAWN` G B K CHECKED: JCGA NO. REVISION BY DATE APPR I APPROVED:JCGA IRRIGATION EQUIPMENT LEGEND ® TORO DRIP CONTROL ZONE KIT DZK-TPV-1-MF H BALL VALVE - PVC NIBCO #4660, SIZE TO MATCH LINE Fv TORO DL2000 AUTOMATIC FLUSH VALVE (INSTALL AT LOW POINT EACH DRIP ZONE) - EXISTING IRRIGATION CONTROLLER (SEE GENERAL NOTE 15) Q RAINBIRD QUICK COUPLING VALVE #44LRC X❑ TORO DL-MP9 DRIP SYSTEM OPERATING INDICATOR ® TORO DL2000 AIR/VACUUM RELIEF VALVE (INSTALL AT HIGH POINT EACH DRIP ZONE) ��rTTTT 0.66 O.D. NETAFIM TECHLINE CV DRIPLINE (0.6 GPH EMITTERS AT 18" I I 111�J O.C.). STAKE DRIPLINE AT 2' O.C. SCHEDULE 40 PVC MAINLINE (SIZED AT 1.0" UNLESS SHOWN OTHERWISE ON PLANS) SCHEDULE 40 PVC LATERAL (3/4" SIZE UNLESS SHOWN OTHERWISE ON PLANS) SCHEDULE 40 PVC SLEEVES (SIZED AT DOUBLE WORKING PIPES) DIAMETER) VALVE LEGEND 1 STATION NUMBER 1 " VALVE SIZE 5 7 GALLONS PER MINUTE IRRIGATION GENERAL NOTES: 1. SEE IRRIGATION DETAILS, SHEET 22 2. THE IRRIGATION PLAN IS DIAGRAMMATIC. INSTALL MAINLINE, VALVES, PIPES, AND ASSOCIATED EQUIPMENT IN PLANTING BEDS IRRIGATION CONSTRUCTION NOTES: 11 P.O.C. FOR IRRIGATION IS STUB -IN TO EXISTING IRRIGATION MAINLINE. CONFIRM LOCATION AND SIZE OF EXISTING IRRIGATION MAINLINE. FIELD -ADJUST P.O.C. AS NEEDED 12 SLEEVE UNDER PAVEMENT 13 EMITTER -IN -LINE DRIP TUBING SPACED @ 2' O.C. (TYP) 14 FIELD -ADJUST DRIPLINE AROUND EXISTING TREE TO REMAIN AS NEEDED 15 EXISTING IRRIGATION CONTROLLER IN JANITORS CLOSET, 1ST FLOOR. EXTEND IRRIGATION CONTROL WIRE FROM NEAREST ZONE VALVE OF EXISTING IRRIGATION SYSTEM IN WIRE SLEEVE CONDUIT LEGEND: 0 "``����� EXISTING TREES TO REMAIN PROJECT LIMITS SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL* NAVD 1988 HORIZONTAL* NAD 1983/1991 DATU M E • CITY OF RENTON ■ Planning/Building/Public Works Dept. 0 O O 0 T 0� O O O T J rw V )00 Cfl 0 QO O CALL BEFORE YOU DIGI Call: TOLL FREE -800-424-5555 1 z 2 w U J w m Q J IN COMPLIANCE WITH CITY OF RENTON STANDARDS W ILL. 10 PLANNING DIVISION Q APPROVED 11/29/2018 jding Q � Q ® 0 DAVID EVANS ANDASSOCIATES INC. 14432 SE Eastgate Way, Suite 400 Bellevue Washington 98007 KING COUNTY REGIONAL AFIS LAB REPLACEMENT IRRIGATION PLAN • R n Ti DATE: I- 01-16-18 z D FIELDBOOK: PAGE: /O U DRAWING NO: L1.1 Z SHEET: OF: 20 135 Y R-399419