Loading...
HomeMy WebLinkAboutJ 119DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E FUSE KITS QUICK REFER TO WSDOT LOCKING DISCONNECT 10 AMP IN LINE LID STANDARD DUTY FUSE KITS S.E.C. OR EQUAL - JUNCTION BOX TYPES 1 & 2 STANDARD PLAN J-40.10 GROUND LUG SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS CONCRETE PAD OR SIDEWALK PER STD PLAN 120 24"(MIN) COVER #8 BARE COPPER GROUND WIRE 1 -#8 EQUIPMENT GROUND WIREW/GREEN INSULATION FROM SERVICE CABINET 2 - LIGHTING SYSTEM WIRES TO CONTACTOR (SIZED AS REQ'D.) NOTES: GROUND CLAMP PVC CONDUI 5/8"x8' COPPER CLAD GROUND ROD TO LUMINAIRE #8 GREEN INSULATED WIRE TO FIXTURE GROUND LUG CONCRETE FOUNDATION 1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY. 2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS. 3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED WIRE OF THE SAME SIZE SHALL RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG. G�•tY O� LUMINAIRE ELECTRICAL STD. PLAN - 119 �� PUBLIC WORKS WIRING SYSTEM A PROVED: �F DEPARTMENT GAZ 3/13/2019 DATE