Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAB-3962167
167
108TH AVE SESE
116TH AVE SE116TH AVE SEBENSON RD SEAST VALLEY RDS 43RD ST BENSON RD SSE 172ND ST
SE 176TH STPROJECT
RDBENSON DR S19 20
30 29
29 28
32 33
30 29
31 32
20 21
29 28
CARRPROJECT INFORMATIONSITE ADDRESS:
TAX PARCELS:
CURRENT ZONING:
17033 108TH AVE SE, RENTON, WA 98055
R-14
65,715 SF (1.51 AC)
PROPOSED USE:
0087000285, 0087000293
FRONT:SETBACKS:
GROSS SITE AREA:
EXISTING USE:
CURRENT COMP PLAN:R-14
15'
REAR:10'
SIDE:
SIDE (ALONG STREET):15'
PARKING REQUIRED:
REQUIRED=
PARKING PROVIDED:26 STALLS
25%%% REDUCTION=
4'
COMPACT STALLS ALLOWABLE:8 STALLS
COMPACT STALLS PROVIDED:7 STALLS
ADA STALLS REQUIRED:2 STALLS
ADA STALLS PROVIDED:2 STALLS
WATER:SOOS CREEK WATER & SEWER DISTRICT
SEWER:
SCHOOL DISTRICT:RENTON #403
POWER:PSE
FIRE DISTRICT:RENTON RFA
GAS:PSE
SOOS CREEK WATER & SEWER DISTRICT
TELEPHONE:CENTURYLINK
CABLE:COMCAST
CONVALESCENT CENTER - CONDITIONAL USE
SINGLE-FAMILY RESIDENTIAL
REFUSE AND RECYCLING AREA
PROVIDED:
REQUIRED RECYCLE:
REQUIRED GARBAGE:102 SF
51 SF
OPEN SPACE REQUIREMENTS
MINIMUM OPEN SPACE REQUIRED:0 SF IF THREE OR FEWER DWELLING UNITS
180 SF
26 STALLS
34 STALLS
MAXIMUM BUILDING HEIGHT:35'
350 SF PER UNIT IF 4 OR MORE DWELLING UNITS
IMPERVIOUS REQUIREMENTS
MAXIMUM IMPERVIOUS:80%%%
MAXIMUM LOT COVERAGE:65%%%
NET SITE AREA 61,150 SF (1.40 AC)
ROW DEDICATION AREA:4,565 SF (0.10 AC)
NEW IMPERVIOUS:43,072 SF (70.40%%%)
NEW PERVIOUS:
LOT COVERAGE:17,306 SF (28.30%%%)
18,078 SF
SEISMIC DESIGN CATEGORY:D
IBC DESIGNATION OF OCCUPANCY:4-1
STRUCTURAL DESIGN CRITERIA:LOAD OF 30 TON VEHICLE, 75 PSI, AND
26"x26" OUTRIGGER PER RENTON RFA
COTTAGE BCOTTAGE CCOTTAGE DCOTTAGE ALOT 14, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED INVOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON.
TOGETHER WITH:
THE SOUTH HALF OF LOT 15, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLATTHEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY,WASHINGTON.
SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.
LEGAL DESCRIPTIONSURVEY INFORMATIONEQUIPMENT & PROCEDURESVERTICAL DATUM - NAVD-88{\Q15;NORTH AMERICAN VERTICAL DATUM-1988}BENCHMARKBENCHMARK
BASIS OF BEARING{\Q15;THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N 01%%D43'32" E}SEPA MITIGATION CONDITIONSPER LUA 17-000023 ECF, CUP MITIGATION MEASURES ARE NONE RECOMMENDED
NPDES PERMIT NUMBER
WAR 305778 CONTACT LISTOWNER/APPLICANT:
LANDSCAPE ARCHITECT:
{ELM ENVIROMENTS1925 POST ALLEY, SUITE 3BSEATTLE, WASHINGTON 98101CONTACT: GREG MURPHYPHONE: (206) 393-8263EMAIL: gmurphy@elmenv.com}
{RENTON SPECIAL CARE COMMUNITY, LLC2731 77TH AVE SE, SUITE 203MERCER ISLAND, WASHINGTON 98040CONTACT: KEVIN CARL}PHONE: (206) 778-4725kevin@magnet-dd.com
CIVIL ENGINEER:
LDC, INC.20210 142ND AVE NEWOODINVILLE, WASHINGTON 98072CONTACT: MARK VILL{W}OCK, PEPHONE: (425) 806-1869{FAX: (425) 482-2893}EMAIL:mvillock@ldccorp.com
ARCHITECT:
GEOTECH:
JENSEN FEY ARCHITECTURE ANDPLANNING P.S.7730 LEARY WAYREDMOND, WASHINGTON 98052CONTACT: REUBEN RIOSPHONE: (425) 216-0318EMAIL: rrios@jensenfey.com
PROFESSIONAL SERVICE INDUSTRIES, INC. (PSI)20508 56TH AVENUE WEST, SUITE ALYNNWOOD, WASHINGTON 98036GEOTECH CONTACT: MICHAEL S. PLACE, PEPHONE: (425) 409-2504{FAX: (425) 582-8193}EMAIL: michael.place@psiusa.com
SURVEYOR:
{LDC, INC.20210 142ND AVE NEWOODINVILLE, WASHINGTON 98072CONTACT: MICHAEL MERRITT, PLS, CFedSPHONE: (425) 806-1869FAX: (425) 482-2893EMAIL:michaelm@ldccorp.com}
CESCL:
{INTERTEK-PSI20508 56TH AVE W, SUITE ALYNWOOD, WA 98043CONTACT: MICHAEL S. PLACE, PEPHONE: (425) 409-2505EMAIL: michael.place@psiusa.com}
HEARING EXAMINER'S REQUIREMENTS
1.A LOT COMBINATION SHALL BE RECORDED PRIOR TO THEISSUANCE OF A BUILDING PERMIT, COMBINING THE TWOPARCELS INTO ONE.2.A DETAILED LANDSCAPE PLAN MEETING THEREQUIREMENTS OF RMC 4-8-120D.12 SHALL BE SUBMITTEDAT THE TIME OF BUILDING PERMIT REVIEW. THE DETAILEDLANDSCAPE PLAN SHALL INCLUDE BUT IS NOT LIMITED TOTHE FOLLOWING:A.A MIX OF TREES, SHRUBS, AND GROUND COVER WITHINTHE 10-FOOT LANDSCAPE STRIP ABUTTING THE SE 172NDSTREET AND 108TH AVENUE SE STREET FRONTAGES;B.THE PROPOSED 10-FOOT FULL SIGHT-OBSCURINGLANDSCAPE VISUAL BARRIER ALONG THE WEST PROPERTYLINE SHALL BE REQUIRED TO EXTEND ALONG THE NORTHPROPERTY LINE; ANDC.VERIFICATION THAT THE INTERIOR PARKING LOTLANDSCAPED AREAS INCLUDE 1 SHRUB PER 20 SQUAREFEET OF PROVIDED INTERIOR PARKING LOT LANDSCAPING,OF WHICH 50 PERCENT OF THE SHRUBS MAY BEDECIDUOUS.THE DETAILED LANDSCAPE PLAN SHALL BE SUBMITTED TOTHE CURRENT PLANNING PROJECT MANAGER FOR REVIEWAND APPROVAL. THE LANDSCAPING SHALL BE INSTALLEDPRIOR TO THE ISSUANCE OF A CERTIFICATE OFOCCUPANCY.3.THE APPLICANT SHALL EITHER REDUCE THE HEIGHT OFTHE FENCE TO COMPLY WITH THE 72-INCH HEIGHTREQUIREMENT OR SUBMIT AN APPLICATION FOR, ANDRECEIVE APPROVAL OF, A SPECIAL FENCE PERMIT INCOMPLIANCE WITH THE STANDARDS OUTLINED IN RMC4-4-040G. THE APPLICANT SHALL SUBMIT A REVISED FENCEDETAIL OR AN APPROVED SPECIAL FENCE PERMIT TO THECURRENT PLANNING PROJECT MANAGER PRIOR TO THEISSUANCE OF A BUILDING PERMIT.4.THE DESIGN OF THE BUILDINGS SHALL BE REQUIRED TOCOMPLY WITH THE RESIDENTIAL DESIGN PORTION OF THERESIDENTIAL DESIGN AND OPEN SPACES STANDARDSAPPLICABLE IN THE R-14 ZONE (RMC 4-2-115E.3) ANDENHANCED LANDSCAPING BE PROVIDED WHERECOMPLIANCE WITH THE ARCHITECTURAL DESIGN CANNOTBE ACHIEVED.5.A LIGHTING PLAN SHALL BE PROVIDED AT THE TIME OFBUILDING PERMIT REVIEW FOR REVIEW AND APPROVAL BYTHE CURRENT PLANNING PROJECT MANAGER.6.THE LOCATION OF THE REQUIRED BICYCLE PARKINGSHALL BE PROVIDED ON THE SITE PLAN AND A DETAIL OFTHE BICYCLE PARKING SHALL BE PROVIDED. THE REVISEDSITE PLAN AND BICYCLE PARKING DETAIL SHALL BEPROVIDED AT THE TIME OF BUILDING PERMIT REVIEW TOTHE CURRENT PLANNING PROJECT MANAGER FOR REVIEWAND APPROVAL.7.A SIDEWALK CONNECTION SHALL BE PROVIDED TO SE172ND STREET ALONG THE WESTERN PORTION OF THEPROJECT SITE.8.ALL PROPOSED LOADING AREAS SHALL BE SEPARATEDFROM PARKING AND PEDESTRIAN AREAS AND SHALL BELOCATED, DESIGNED AND SCREENED TO MINIMIZE VIEWS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18VICINITY MAPSCALE: 1"=2000'
RENTON SPECIAL
CARE COMMUNITYSCALE: 1" =
0
40'
40'40'80'COVER SHEET1"=30'
CS-01
230AS-BUILT DRAWINGS
TABLE OF CONTENTS
1 COVER SHEET2 EXISTING CONDITIONS MAP
3 HORIZONTAL CONTROL PLAN
4 SITE PLAN5 TESC PLAN
6-7TESC NOTES AND DETAILS
8 GRADING PLAN9 DETAILED GRADING PLAN10 {\Q15;ROAD AND STORM DRAINAGE PLAN}11-15{\Q15;ROAD AND STORM DRAINAGE PROFILES}
16 ROAD SECTIONS
17 {\Q15;STORM DRAINAGE DETENTION PLAN}18 {\Q15;COMPOSITE UTILITY PLAN}19-23{\Q15;NOTES AND DETAILS}
WA-01 - WA-05 WATER PLANS
SS-01 - SS-06SEWER PLANSL000 TREE INVENTORY AND RETENTION PLAN
L100-L301 LANDSCAPE PLANS
ES-01 - ES-03 LIGHTING PLANS70.30'(R4)661.35'(P)
661.23'(R2)719.94'(R3)158.38'(C)719.91'(M)
N88%%D07'55"E
N88%%D13'13"W
70.31'(C)158.39'(C)N88%%D07'55"W 300.54'(C)300.62'(P)139.15'(P)139.24'(C)70.34'(C)70.30'(R4)SE 172ND ST{BLOCK 4LOT 14}
{BLOCK 4LOT 13}
{BLOCK 4LOT 15}
{BLOCK 4LOT 12}
STORM PIPE
STORM CLEAN OUT
ROUND YARD DRAIN
SQUARE YARD DRAIN
TYPE 2 CATCH BASIN, SOLID LID
TYPE 2 CATCH BASIN, GRATED LID
TYPE 1 CATCH BASIN, SOLID LID
TYPE 1 CATCH BASIN, GRATED LID
SD CAP
CONCRETE BLOCKING
90%%d BEND
VALVE
HYDRANT ASSEMBLY
BLOW-OFF VALVE
REDUCER
AIR-VAC ASSEMBLY
DESCRIPTIONSYMBOL
PROPOSED WATER SYMBOLS
PROPOSED STORM SYMBOLS
SYMBOL DESCRIPTION
WATER PIPE
SEWER CLEANOUT
SEWER MANHOLE
DESCRIPTIONSYMBOL
PROPOSED SEWER SYMBOLS
SEWER PIPE
EXISTING SYMBOLS
DESCRIPTIONSYMBOL
ABBREVIATIONS
SANITARY SEWER MANHOLESSMH
PP POWER POLE
EXIST.EXISTING
CATCH BASINCB
PROPERTY LINE
FLOWLINE%%132CENTERLINE
CONCRETE PIPECP
TYPICALTYP
ELEVATIONEL
R/W RIGHT-OF-WAY
CMP CORRUGATED METAL PIPE
INVERT ELEVATIONIE
SS SANITARY SEWER
STORM DRAINSD
STATIONSTA
LCPE LINED CORRUGATED POLYETHYLENE PIPE
POLYVINYL CHLORIDE PIPEPVC
SWPE SOLID WALL POLYETHYLENE PIPE
TO BE REMOVEDTBR
SEWER CAP
LEGEND AND ABBREVIATIONS
WATER METER
S
T
FOUND CASED MONUMENT, AS NOTED
FOUND REBAR & CAP, AS NOTED
SET REBAR AND CAP
STORM DRAIN MANHOLE
STORM DRAIN CATCH BASIN
SANITARY SEWER MANHOLE
NATURAL GAS VALVE
FIRE HYDRANT
WATER VALVE
WATER METER
BOLLARD
POWER POLE W/LIGHT
TELEPHONE MANHOLE
MAPLE TREE
CEDAR TREE
POWER POLE
299.81'(C)
DRIVE A
DRIVE A
58.68'(R2)
SET REBAR AND CAPEMW LS#44651
108TH AVE SE
1274.24'(P)1275.03'(M)\pxql;FOUND REBAR AND CAP CRONES LIES 0.32' N17°W OF PROPERTY CORNER
SET REBAR AND CAPEMW LS#44651
\pxt0;FOUND 1.5" PIPE 0.85' N11°W OF PROPERTY CORNER
SET REBAR AND CAPEMW LS#44651
\pxql;FOUND CASED MONUMENT
SET REBAR AND CAPEMW #44651
SET REBAR AND CAPEMW LS#44651
FOUND CASED MONUMENT W/TACK
FOUNDCASEDMONUMENT
SET REBAR AND CAPEMW LS#44651
\pxql;FOUND CASED MONUMENT
LANDSCAPE NOTES
\pxi-2,l2,t2;1.LANDSCAPE PLAN WILL BE REVISE TO MATCH STREET LIGHT LOCATIONS ON THE CIVIL PLANS AND TREE LOCATIONS WILL BE ADJUSTED ACCORDINGLY.
106TH AVE SE 3842.13'N56°49'35"W
2554.59'N30°05'55"E702.23'CITY OF RENTON MON#1862 (C, HORZONLY)COPPER PLUG WITH PUNCH ON A 4"X4"CONCRETE POST, IN CASE, DOWN 0.45'.PUBLISHED CO-ORDS:N=168056.01E=1300198.93FOUND CO-ORDS:N=168056.34
CITY OF RENTON MON#1640 (D, HORZ & ELEV)3" BRASS DISC STAMPED "KING COUNTY SURVEYMONUMENT", IN CASE, DOWN 1.0'.PUBLISHED CO-ORDS:N=170648.98E=1305835.75ELEV=466.09FOUND CO-OORDS:N=170649.17E=1305835.94ELEV=465.87
CITY OF RENTON MON#1915 (B, ELEV ONLY)COPPER PLUG IN A 3" CONCRETE FILLED PIPE IN AWSDOT CASE. DOWN 0.30'.PUBLISHED CO-ORDS:ELEV=380.86FOUND CO-OORDS:ELEV=380.70
AS-BUILT DRAWINGSRecord Drawings shall be prepared, stamped, and signed by a Professional Engineer or Professional Land Surveyor Licensed in the State
of Washington. All plans showing as-built information in the Record Drawings and the cover sheet of the Record Drawings shall include
a stamp that indicates that the plan sheet contains as-built information. The stamp shall be labeled “Construction Record Drawing”. The
stamp shall indicate how the as-built information was obtained and that the professional stamping the plan sheet takes ownership for the
contents of the plan sheet. Something like the following:
SCALE: 1" =
0
20'
20'20'40'
S
T
FOUND CASED MONUMENT, AS NOTED
FOUND REBAR & CAP, AS NOTED
SET REBAR AND CAP
STORM DRAIN MANHOLE
STORM DRAIN CATCH BASIN
SANITARY SEWER MANHOLE
NATURAL GAS VALVE
FIRE HYDRANT
WATER VALVE
WATER METER
BOLLARD
POWER POLE W/LIGHT
TELEPHONE MANHOLE
MAPLE TREE
CEDAR TREE
POWER POLE
LEGEND
R-396202
EXISTING CONDITIONS MAP
1"=20'
TO-01
2321FOUND CASED MONUMENTW/TACK
N88%%D07'55"W158.39'(C)70.31'(C)N88%%D13'13"W 299.81'(C)139.24'(C)1275.03'(M)300.62'(P)300.54'(C)158.38'(C)139.15'(P)1274.24'(P)661.23'(R2)70.30'(R4)70.34'(C)70.30'(R4)661.35'(P)
719.91'(M)719.94'(R3)SSMHRIM=410.63'IE=397.96'(N,S,E 8" PVC)
SSMHRIM=412.67'IE=398.48'(N,S,E,W)IE=404.71'(N,8")
N88%%D07'55"E
106TH AVE SE TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
CITY OF RENTON MON#1915 (B, ELEVONLY)COPPER PLUG IN A 3" CONCRETE FILLEDPIPE IN A WSDOT CASE. DOWN 0.30'.PUBLISHED CO-ORDS:ELEV=380.86FOUND CO-OORDS:
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-183842.13'CITY OF RENTON MON#1640 (D, HORZ & ELEV)3" BRASS DISC STAMPED "KING COUNTY SURVEYMONUMENT", IN CASE, DOWN 1.0'.PUBLISHED CO-ORDS:N=170648.98E=1305835.75ELEV=466.09FOUND CO-OORDS:N=170649.17E=1305835.94ELEV=465.87
N56°49'35"W
2554.59'
CITY OF RENTON MON#1862 (C, HORZ ONLY)COPPER PLUG WITH PUNCH ON A 4"X4"CONCRETE POST, IN CASE, DOWN 0.45'.PUBLISHED CO-ORDS:N=168056.01E=1300198.93FOUND CO-ORDS:N=168056.34E=1300199.16 AS-BUILT DRAWINGS
PROJECT INFORMATIONSITE ADDRESS:
TAX PARCELS:
CURRENT ZONING:
17033 108TH AVE SE, RENTON, WA 98055
R-14
65,715 SF (1.51 AC)
PROPOSED USE:
0087000285, 0087000293
FRONT:SETBACKS:
GROSS SITE AREA:
EXISTING USE:
CURRENT COMP PLAN:R-14
15'
REAR:10'
SIDE:
SIDE (ALONG STREET):15'
PARKING REQUIRED:
REQUIRED=
PARKING PROVIDED:26 STALLS
25%%% REDUCTION=
4'
COMPACT STALLS ALLOWABLE:8 STALLS
COMPACT STALLS PROVIDED:7 STALLS
ADA STALLS REQUIRED:2 STALLS
ADA STALLS PROVIDED:2 STALLS
WATER:SOOS CREEK WATER & SEWER DISTRICT
SEWER:
SCHOOL DISTRICT:RENTON #403
POWER:PSE
FIRE DISTRICT:RENTON RFA
GAS:PSE
SOOS CREEK WATER & SEWER DISTRICT
TELEPHONE:CENTURYLINK
CABLE:COMCAST
CONVALESCENT CENTER - CONDITIONAL USE
SINGLE-FAMILY RESIDENTIAL
REFUSE AND RECYCLING AREA
PROVIDED:
REQUIRED RECYCLE:
REQUIRED GARBAGE:102 SF
51 SF
OPEN SPACE REQUIREMENTS
MINIMUM OPEN SPACE REQUIRED:0 SF IF THREE OR FEWER DWELLING UNITS
180 SF
26 STALLS
34 STALLS
MAXIMUM BUILDING HEIGHT:35'
350 SF PER UNIT IF 4 OR MORE DWELLING UNITSIMPERVIOUS REQUIREMENTS
MAXIMUM IMPERVIOUS:80%%%
MAXIMUM LOT COVERAGE:65%%%
NET SITE AREA 61,150 SF (1.40 AC)
ROW DEDICATION AREA:4,565 SF (0.10 AC)
NEW IMPERVIOUS:43,072 SF (70.40%%%)
NEW PERVIOUS:
LOT COVERAGE:17,306 SF (28.30%%%)
18,078 SF
SEISMIC DESIGN CATEGORY:D
IBC DESIGNATION OF OCCUPANCY:4-1
STRUCTURAL DESIGN CRITERIA:LOAD OF 30 TON VEHICLE, 75 PSI, AND
26"x26" OUTRIGGER PER RENTON RFA
LOT 14, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED INVOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON.
TOGETHER WITH:
THE SOUTH HALF OF LOT 15, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLATTHEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY,WASHINGTON.
SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.
LEGAL DESCRIPTIONSURVEY INFORMATIONEQUIPMENT & PROCEDURESVERTICAL DATUM - NAVD-88{\Q15;NORTH AMERICAN VERTICAL DATUM-1988}BENCHMARKBENCHMARK
BASIS OF BEARING{\Q15;THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N 01%%D43'32" E}
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396203
HORIZONTAL CONTROL PLAN
1"=20'
HC-01
232\A1;15.6'\A1;45.9'\A1;101.3'\A1;101.3'\A1;52.6'
\A1;52.6'\A1;100.2'\A1;57.8'
15.5'R/WDEDICATION\A1;23.6'\A1;30.5'\A1;20.5'
4.5' R/W DEDICATION
30'EX R/W\A1;30'
\A1;EX R/W
\A1;18.6'60'EX R/W10' LANDSCAPE BUFFER
\A1;R25'
\A1;R45'\A1;69.8'\A1;44.5'\A1;40.3'\A1;71'
30'EX R/W
\A1;30'\A1;30'FOUND CASED MONUMENTW/TACK
SCALE: 1" =
0
20'
20'20'40'
N88%%D07'55"W158.39'(C)70.31'(C)N88%%D13'13"W 299.81'(C)139.24'(C)1275.03'(M)300.62'(P)300.54'(C)158.38'(C)139.15'(P)1274.24'(P)661.23'(R2)70.30'(R4)70.34'(C)661.35'(P)
719.91'(M)
3'X6' WATER EASEMENT(REC. NO. 8008130467)(TO BE RELINQUISHED)
719.94'(R3)
N88%%D07'55"E
INTERSECTION, ROAD %%132
STA 0+00.00, DRIVE A=
STA 16+89.94, SE 172ND ST
N=166701.26
E=1302727.41
N=166859.58
E=1302732.27
N=166929.86
E=1302734.43
N=166920.54
E=1303034.10
N=166711.06
E=1303027.78
N=166850.23
E=1303031.98
INTERSECTION, ROAD %%132
STA 5+19.12, DRIVE A=
STA 12+13.23, 108TH AVE SE
\A1;30'\A1;EX R/W15'x12' POWER ESMT
3'X6' WATER ESMT
\A1;10'
SDESMT
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
\A1;10'
SDESMT\A1;20' CITYEMERGENCYACCESS ESMT\A1;20' CITY
EMERGENCYACCESS ESMT
16'WATER &SEWER ESMT
106TH AVE SE \A1;64.1'\A1;BUILDING SETBACK\A1;15.3'
\A1;39'\A1;52.6'\A1;15.3'
TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
INTERSECTION, ROAD %%132
STA 20+00.00, SE 172ND ST
STA 10+00.00, 108TH AVE SE=
CITY OF RENTON MON#1915 (B, ELEV ONLY)COPPER PLUG IN A 3" CONCRETE FILLED PIPE IN AWSDOT CASE. DOWN 0.30'.PUBLISHED CO-ORDS:ELEV=380.86FOUND CO-OORDS:ELEV=380.70
N56°49'35"W
2554.59'
CITY OF RENTON MON#1862 (C, HORZONLY)COPPER PLUG WITH PUNCH ON A 4"X4"CONCRETE POST, IN CASE, DOWN 0.45'.PUBLISHED CO-ORDS:N=168056.01E=1300198.93FOUND CO-ORDS:N=168056.34
N30°05'55"E702.23'3842.13'CITY OF RENTON MON#1640 (D, HORZ & ELEV)3" BRASS DISC STAMPED "KING COUNTY SURVEYMONUMENT", IN CASE, DOWN 1.0'.PUBLISHED CO-ORDS:N=170648.98E=1305835.75ELEV=466.09FOUND CO-OORDS:N=170649.17E=1305835.94ELEV=465.87
\A1;10'GASESMT\A1;10'GASESMT\A1;57'
\A1;UTILITY ESMT \A1;20' SD ESMT\A1;UTILITY ESMT\A1;WIDTH VARIES\A1;18'
WATER&SEWER \A1;15'WATERESMT\A1;10'WATERESMT\A1;15'WATERAS-BUILT DRAWINGS
PROJECT INFORMATIONSITE ADDRESS:
TAX PARCELS:
CURRENT ZONING:
17033 108TH AVE SE, RENTON, WA 98055
R-14
65,715 SF (1.51 AC)
PROPOSED USE:
0087000285, 0087000293
FRONT:SETBACKS:
GROSS SITE AREA:
EXISTING USE:
CURRENT COMP PLAN:R-14
15'
REAR:10'
SIDE:
SIDE (ALONG STREET):15'
PARKING REQUIRED:
REQUIRED=
PARKING PROVIDED:26 STALLS
25%%% REDUCTION=
4'
COMPACT STALLS ALLOWABLE:8 STALLS
COMPACT STALLS PROVIDED:7 STALLS
ADA STALLS REQUIRED:2 STALLS
ADA STALLS PROVIDED:2 STALLS
WATER:SOOS CREEK WATER & SEWER DISTRICT
SEWER:
SCHOOL DISTRICT:RENTON #403
POWER:PSE
FIRE DISTRICT:RENTON RFA
GAS:PSE
SOOS CREEK WATER & SEWER DISTRICT
TELEPHONE:CENTURYLINK
CABLE:COMCAST
CONVALESCENT CENTER - CONDITIONAL USE
SINGLE-FAMILY RESIDENTIAL
REFUSE AND RECYCLING AREA
PROVIDED:
REQUIRED RECYCLE:
REQUIRED GARBAGE:102 SF
51 SF
OPEN SPACE REQUIREMENTS
MINIMUM OPEN SPACE REQUIRED:0 SF IF THREE OR FEWER DWELLING UNITS
180 SF
26 STALLS
34 STALLS
MAXIMUM BUILDING HEIGHT:35'
350 SF PER UNIT IF 4 OR MORE DWELLING UNITSIMPERVIOUS REQUIREMENTS
MAXIMUM IMPERVIOUS:80%%%
MAXIMUM LOT COVERAGE:65%%%
NET SITE AREA 61,150 SF (1.40 AC)
ROW DEDICATION AREA:4,565 SF (0.10 AC)
NEW IMPERVIOUS:43,072 SF (70.40%%%)
NEW PERVIOUS:
LOT COVERAGE:17,306 SF (28.30%%%)
18,078 SF
SEISMIC DESIGN CATEGORY:D
IBC DESIGNATION OF OCCUPANCY:4-1
STRUCTURAL DESIGN CRITERIA:LOAD OF 30 TON VEHICLE, 75 PSI, AND
26"x26" OUTRIGGER PER RENTON RFA
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18\A1;16'9'TYP\A1;20'\A1;24'\A1;DRIVE AISLE\A1;20'
\A1;DRIVE AISLE
\A1;27'\A1;24'\A1;45.9'\A1;52.6'\A1;101.3'\A1;101.3'
\A1;52.6'
\A1;52.6'\A1;100.2'\A1;57.8'\A1;23.6'\A1;31.7'15.5' R/W DEDICATION
4.5' R/W DEDICATION \A1;8'22'
PVMT\A1;30' EX R/W
\A1;18.6'10' LANDSCAPE BUFFER \A1;20' CITYEMERGENCYACCESS ESMT\A1;R25'
\A1;R45'\A1;69.8'\A1;24'\A1;DRIVE AISLE
\A1;64.1'\A1;44.5'\A1;20'\A1;9'\A1;40.3'SCALE: 1" =
0
20'
20'20'40'
\A1;11'22.2'PVMT
\A1;26'128.72'
LEGEND
SEWER PIPE
WATER PIPE
STORM PIPE
DRAIN PIPE
ROOFLINE
\A1;30'1275.03'(M)1274.24'(P)R-396204SITE PLAN1"=20'
SP-01
233FOUND CASED MONUMENTW/TACK 9'TYP4.51'15.50'
N88°07'55"E 273.74'
COVERED REFUSE AND RECYCLING AREA
DRIVE A
10' LANDSCAPE BUFFER
FUTURE PAVEMENT AND ROAD WORK BY "AVANA RIDGE" DEVELOPMENT
15'x12' POWER ESMT.
COVERED BIKE RACK
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
6' CEDAR FENCE TO BE INSTALLED DIRECTLY ADJACENT TO PROPERTY LINE
SAW CUT LINE, TYP
6'{PRK}5'{BIKE}
PER STD 104.3SEE DT-04
\A1;10'
SDESMT
EXISTING CULVERT TO BE REMOVED
\A1;15.3'\A1;15.6'N=166929.86
E=1302734.43
N=166701.26
E=1302727.41
N=166859.58
E=1302732.27
N=166850.23
E=1303031.98
E=1303034.10
STORM DETENTIOM CLEAN OUT
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
YARD DRAIN
3'X6' WATER ESMT
30'EX R/W60'EX R/WSE 172ND STPER STD 104.3SEE DT-04
\A1;20'\A1;30'N=166711.06
E=1303027.78
30'EX R/W
661.35'(P)
661.23'(R2)
108TH AVE SE
106TH AVE SE
\A1;15.3'
\A1;39'
\A1;20.5'
N=166920.54
\A1;16'\A1;10'GASESMT\A1;8'8'PVMT\A1;18'\A1;10'
SDESMT
EXISTING LIGHT POLE TO BE REMOVED AND REPLACED\A1;20' SD ESMTEXISTING LIGHT POLE TO BE REMOVED AND REPLACED
STOP SIGN
\A1;20' CITY
EMERGENCYACCESS ESMT
AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396205
TESC PLAN
1"=20'
ER-01
234IE=401.50
IE=401.50
40 LF 12" SD @ 15.0%%%
25 LF 12" SD @ 9.1%%%
63 LF 12" SD @ 9.5%%%
IE=395.50
CLEARING LIMITS
TESC POND, STD PLAN 216.00, ER-02
CLEARING AREA
PROTECTED AREA
SILT FENCE, STD. PLAN 214.00, ER-02
ROCK CONSTRUCTION ENTRANCE1
PRE DEVELOPMENT DRAINAGE PATTERN
RIP RAP PAD
INSTALL CHECK DAM EVERY 100' OR 2' OF ELEVATION CHANGE, STD. PLAN 217.40, ER-03
CONVEYANCE SWALE
LEGEND
SCALE: 1" =
0
20'
20'20'40'
POST DEVELOPMENT DRAINAGE PATTERN
1
TBR
TBR
TBR
1.PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALLSCHEDULE AND ATTEND A PRE-CONSTRUCTION CONFERENCE WITH THE CITYOF RENTON STAFF. CESCL SHALL ATTEND CONFERENCE.2.FLAG CLEARING LIMITS.3.POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR.4.INSTALL CATCH BASIN PROTECTION ONSITE AND WITHIN 500'DOWNSTREAM OF SUBJECT PROPERTY.5.GRADE AND INSTALL ROCK CONSTRUCTION ENTRANCE.6.INSTALL FILTER FABRIC FENCE AND CONSTRUCTION FENCE AS SHOWN.7.CONSTRUCT SEDIMENT TRAP AND OUTFALL.8.GRADE AND STABILIZE CONSTRUCTION ROADS.9.CONSTRUCT SURFACE WATER CONTROLS (CONVEYANCE SWALES, CHECKDAMS AND TEMPORARY CULVERTS) SIMULTANEOUSLY WITH CLEARING ANDGRADING FOR PROJECT DEVELOPMENT.10.MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OFRENTON STANDARDS AND MANUFACTURER'S RECOMMENDATIONS.11.RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURESSO THAT AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENTCONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY ESC MINIMUMREQUIREMENTS.12.COVER ALL AREAS WITHIN THE SPECIFIED TIME FRAME WITH STRAW,WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, CRUSHED ROCK OREQUIVALENT.13.STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS.14.SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30DAYS.15.CLEAN OUT STORM SYSTEM INCLUDING SEDIMENT TRAP ANDSTRUCTURES WHEN CONSTRUCTION IS COMPLETE AND SITE HAS STABILIZED.16.UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BESTABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE.CONSTRUCTION SEQUENCETBR TO BE REMOVED
TEMPORARY STOCK PILE
IE=395.50
IE=391.23
CATCH BASIN PROTECTION, STD PLAN 216.30, ER-03
TBRTBRTBR
\pxqc;6' TALL CHAINLINK PROTECTIVE FENCE (5' BEYOND DRIP LINE)
TBR
TBRAS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396206
TESC NOTES AND DETAILS
AS NOTED
ER-02
235EROSION CONTROL NOTES
1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITYOCCURS, A PRECONSTRUCTION MEETING MUST BE HELDWITH THE CITY OF RENTON, PUBLIC WORKS DESIGNENGINEER.2.ALL LIMITS OF CLEARING AND AREAS OF VEGETATIONPRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BECLEARLY FLAGGED IN THE FIELD AND OBSERVED DURINGCONSTRUCTION.3.ALL REQUIRED SEDIMENTATION/EROSION CONTROLFACILITIES MUST BE CONSTRUCTED AND IN OPERATIONPRIOR TO LAND CLEARING AND/OR CONSTRUCTION TOENSURE THAT SEDIMENT LADEN WATER DOES NOT ENTERTHE NATURAL DRAINAGE SYSTEM. ALL EROSION ANDSEDIMENT FACILITIES SHALL BE MAINTAINED IN ASATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARINGAND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FORON-SITE EROSION HAS PASSED. THE IMPLEMENTATION,MAINTENANCE, REPLACEMENT AND ADDITIONS TOEROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THERESPONSIBILITY OF THE PERMITTEE.
4.THE EROSION AND SEDIMENTATION CONTROL SYSTEMSDEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUMREQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. ASCONSTRUCTION PROGRESSES AND UNEXPECTED ORSEASONAL CONDITIONS DICTATE, THE PERMITTEE SHALLANTICIPATE THAT MORE EROSION AND SEDIMENTATIONCONTROL FACILITIES WILL BE NECESSARY TO ENSURECOMPLETE SILTATION CONTROL ON THE PROPOSED SITE.DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THEOBLIGATION AND RESPONSIBILITY OF THE PERMITTEE TOADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BYTHE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES,OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BENEEDED, TO PROTECT ADJACENT PROPERTIES AND WATERQUALITY OF THE RECEIVING DRAINAGE SYSTEM.5.APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATIONCONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OFSTORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES,RESTRICTORS, CHANNELS, OR RETENTION FACILITIES.6.DURING THE TIME PERIOD OF OCTOBER 1ST THROUGHAPRIL 30TH, ALL PROJECT DISTRIBUTED SOIL AREASGREATER THAN 5,000 SQUARE FEET, THAT ARE TO BE LEFTUN-WORKED FOR MORE THAN 12 HOURS, SHALL BE COVEREDBY MULCH, SODDING OR PLASTIC COVERING.7.IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATIONAND WHERE NO FURTHER WORK IS ANTICIPATED FOR APERIOD 30 DAYS OR MORE, ALL DISTURBED AREAS MUST BEIMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTINGOR OTHER APPROVED EROSION CONTROL TREATMENTAPPLICABLE TO THE TIME OF YEAR. GRASS SEEDING ALONEWILL BE ACCEPTABLE ONLY DURING THE MONTHS OF APRILTHROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED,HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE
PERMITTEE, BUT MUST BE AUGMENTED WITH MULCHING,NETTING OR OTHER TREATMENT APPROVED BY THE CITY OFRENTON, OUTSIDE THE SPECIFIED TIME PERIOD.8.FOR ALL EROSION/SEDIMENTATION CONTROL PONDSWHERE THE DEAD STORAGE DEPTH EXCEEDS 6 INCHES, AFENCE IS REQUIRED WITH A MINIMUM HEIGHT OF THREE (3)FEET, 3:1 SIDE SLOPES.9.A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE, 24FEET X 50 FEET X 8 INCHES OF 4 TO 6 INCH QUARRY SPALLS
393.50
396.00
3:1
784 SF
397.00
16 SF
393.00
OUTLET INVERT ELEV.
OVERFLOW ELEV.
SIDE SLOPES
TOP AREA (SF)
TOP ELEVATION
BOTTOM AREA (SF)
BOTTOM ELEVATION
TESC SEDIMENTATION POND
393.50ORIFICE INVERT ELEV.
1 1/8"%%CORIFICE SIZE
3.5' MIN.
NOTE:
\pxa0.5,t3;FOR POND, ORIFICE, EMERGENCY OVERFLOW SIZING SEE SWPPP APPENDIX A.AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396207
TESC NOTES AND DETAILS
AS NOTED
ER-03
236AS-BUILT DRAWINGS
EARTHWORK QUANTITIES
CUT:
FILL:
DISTURBED/CLEARING AREA:
7,466 CY (10,500 TONS)
4,991 CY (7,000 TONS)
87,170 SF (2.00 AC)
NET:2,2475 CY FILL/IMPORT (3,500 TONS)
*NOTE:NET EARTHWORK VOLUME ESTIMATE ASSUMES 50%%% OF EXCAVATED
SOILS WILL BE UNSUITABLE FOR SITE BACKFILL USE.
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18T
B409.1402.0
7.1\A1;24'\A1;20'\A1;8'
\A1;8'
\A1;30' EX R/W
SCALE: 1" =
0
20'
20'20'40'
15.5' R/W DEDICATION
LEGEND
SEWER PIPE
WATER PIPE
STORM PIPE
DRAIN PIPE
ROOFLINE
STORM DETENTIOM CLEAN OUT
PERVIOUS PAVEMENT
22'PVMT \A1;22.2'
\A1;PVMT30'EX R/W
\A1;30'
R-396208GRADING PLAN1"=20'
GR-01
2370.5%0.8%
0.5%0.5%0.8%
0.5%
0.6%1.0%1.0%
1.0%
1.0%0.9%0.5%
0.6%0.6%0.6%%%
410.44410.50410.45
410.502.93%
2.75%
2.5%0.75%
3.1%
2.0%
1.8%
2.7%2.0%1.0%3.0%3.0%1.9%2.0%0.5%0.5%1.0%1.0%1.5%
2.5%
1.0%6.4%1.0%5.9%%%10' LANDSCAPE BUFFER
20' CITY EMERGENCY ACCESS ESMT 0.5%%%0.5%0.5%%%
2.0%
NOTE
1.SEE SHEET GR-02 FOR ADDITIONAL DETAILED GRADING.2.SEE APPROVED BUILDING PERMIT B17004403 FOR CONSTRUCTIONDETAILS FOR RETAINING WALLS.
3.THE RETAINING WALL ADJACENT TO COTTAGE D WILL NOT CUASE ATRAFFIC VISION HAZARD FOR DRIVERS EXITINGONTO SE 172ND STREETBECAUSE THE FACE OF THE RETAINING WALL IS SET BACK 33 FEET FROMTHE FACE OF CURB NEAR THE EXIT. THE WALL WILL NOT OBSTRUCT ANYPORTION OF THE DRIVER'S VIEW OF SE 172ND AS THE VEHICLE.
1.0%%%12.2%%%FUTURE PAVEMENT AND ROAD WORK BY "AVANA RIDGE" DEVELOPMENT
15'x12' POWER ESMT.1.0%%%10' LANDSCAPE BUFFER
T B
410.1405.34.8T
B
410.0
407.9 2.1
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER5.2%%%T
B 408.2404.6
3.6T
B
406.1402.1 4
T
B
404.7
401.1 3.6
4.5' R/W DEDICATION
T
B409.0
407.2
1.8
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
YARD DRAIN
EXISTING CULVERT TO BE REMOVED
LIMITS OFFUTURERESTORATION BY"AVANA RIDGE"
LIMITS OF FUTURE RESTORATION BY"AVANA RIDGE"16+45.93, 18.00'
10' LANDSCAPE BUFFER T
B
410.1409.01.13'X6' WATER ESMT
\A1;18'\A1;PVMT30'EX R/W\A1;1'\A1;30'\A1;26'\A1;PVMT\A1;10'
SDESMT \A1;10'GASESMT\A1;20' CITYEMERGENCYACCESS ESMT\A1;10'
SDESMT
T
B410.1403.5
6.6
T
B409.1402.6
6.5T
B409.1402.3
6.8
T
B409.1402.7
6.4
T
B
409.1403.1 6
T
B
410.1405.0 5.1
AA
\A1;57'
\A1;UTILITY ESMT
T
B409.1403.35.8
B
B
T
B
410.1403.36.8CONNECT DRAIN LINE TO CONTROL STRUCTURE \A1;20' SD ESMT16'WATER &SEWER ESMT 410.46SPOT ELEVATIONS WERE NOT AS-BUILTAS-BUILT NOTEAB
AB
AB
AB
AB
ABAB
AB
AB
ABABAB
AB
AB
AB
AB
AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18SCALE: 1" =
0
10'
10'10'20'
R-396209
DETAILED GRADING PLAN
AS NOTED
GR-02
2381.0%4.89%1.5%0.6%1.0%1.0%1.0%5.0%
1.5%5.2%
3.3%
7.7%1.0%1.0%2.0%2.0%4.0%1.0%1.0%4.5%1.5%1.0%2.0%4.0%
6.7%%%
6.9%%%
2.9%
4.4%
SCALE: 1"=10'SE 172ND ST AND 108TH AVE SESCALE: 1"=10'SE 172ND ST AND DRIVE ADRIVE A
108TH AVE SE
SE 172ND STCURB RETURN #1
%%130=86°24'36"
R=30.0'
L=45.24'
A
B0+0010+0017+00
19+00
20+00
NOTES
\pxi-2,l2,t2;1.SEE RENTON STANDARD PLANS FOR DRIVEWAY STANDARDS COR STD PLAN 104.3 TYPE R1B
2
GB
1
2
2
2
2
1
1 2
GB
GB
GB
GB
GB
B
A
KEY MAP
NOT TO SCALE ADA RAMP NOTES1
2
CURB RETURN #2
%%130=99°59'58"
R=30.0'
L=52.36'
1
1.4%%%
6.4%%%1.4%%%1
4.5%
2 STA 19+42.4 8.0' RTSTA 19+70.5 44.2' RT
C
A B
D DRIVE A5.0%%%1.5%%%4.9%
6.4%%%6.5%%%0.8%1.5%%%5.0%4.0%0.8%%%0.7%%%3.0%1.92%1.5%5.0%1.5%1.5%2.0%4.10%
3.0%
5.74%1.5%6.25%2
2
4.8%%%
5.2%%%
1.5%%%4.8%%%1.7%%%1.7%%%STA 10+44.83 22.00' LT
STA 19+50.9 18.00' LTSCALE: 1"=10'C
108TH AVE SE
DRIVE A
C
SE 172ND ST108TH AVE SE
SE 172ND STTOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
6.9%%%
2.5%%%7.0%%%1.4%%%0.7%%%
4.4%
2.6%%%7.5%%%7.5%%%1.3%%%1.3%%%5.4%%%7.5%1.5%\A1;5.41\A1;5.07
\A1;7.54\A1;5.3\A1;4\A1;15.39\A1;6.14 SPOT ELEVATIONS WERE NOT AS-BUILTAS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-1829 LF 8" PVC @ 4.83%%%
71 LF 8" PVC @ 2.50%%%
200 LF 12" PVC @ 1.78%%%
\A1;15'
\A1;27.7'\A1;24'\A1;DRIVE AISLE\A1;24'\A1;DRIVE AISLELEGEND
SEWER PIPE
WATER PIPE
STORM PIPE
DRAIN PIPE
SCALE: 1" =
0
20'
20'20'40'
2'
ROOFLINE
NOTES
1.ALL ROOF DRAIN PIPE IS 6"%%C AT 2.0% MIN SLOPE UNLESS OTHERWISESPECIFIED.2.SEE SHEET RD-02-RD-06 FOR ROAD AND STORM DRAINAGE PROFILES.3.SEE SHEET SD-01 FOR STORM DRAINAGE DETENTION PIPE DETAILS.
22'PVMT \A1;22.7'
\A1;PVMT30'R/W
\A1;30'\A1;30'R-396210
ROAD AND STORM DRAINAGE PLAN
1"=20'
RD-01
230/CB-A17
CB-A16
EX-CB
\A1;30'\A1;35'\A1;35'
\A1;23'\A1;23'\A1;23'ZERO HEIGHT CONCRETE CURB FROMSTA 3+53 - STA 4+63SEE DT-03
CONCRETE VALLEY GUTTERFROM STA 2+44 -STA 3+53. SEE DT-03
#UTILITY CROSSING
PIPE CROSSING TABLE8" PVC PIPE BOTTOM=400.88
12" SS TOP=399.01
8" PVC PIPE BOTTOM=403.75
8" WATER TOP=402.25
STA 1+23.22, 22.00' RT. (DRIVE A)
1
2
PIPE SEPARATION=1.87'
STA 1+23.22, 30.40' RT. (DRIVE A)
PIPE SEPARATION=1.50'
2
1
RIM=410.35
IE=408.25
RIM=410.30
IE=403.68
RIM=410.40
IE=404.14
RIM=410.30
IE=404.74
RIM=410.32
IE=407.46
RIM=410.37
IE=405.22
RIM=408.0
IE=405.50
FILTERRA 10'X6' ENHANCED WATER QUALITY TREATMENT VAULT
30'R/W
470 LF 8'%%C STORMWATER DETENTION TANK SEE SHEET SD-01 FOR ADDITIONAL DETAILS
CB-4,TYPE-1
STA. 1+23.22, 9.22' LT
CB-5,CONCRETE INLET
STA. 2+07.40, 16.19' LT
CB-6,CONCRETE INLET
STA. 2+43.92, 9.25' RT CB-7,TYPE 1
STA. 3+52.81, 9.25' RT
CB-2 TYPE-2
CONTROL STRUCTURE
STA. 0+73.24, 1.57' LT
CB-1,TYPE-2-48"
STA. 0+16.76, 5.95' LT
CB-16,TYPE-2-48"
STA. 16+60.71, 2.69' LT
36 LF 6" PVC @ 8.97%%%
CB-10,TYPE-2-48"
W/ SOLID LOCKING LID
STA. 1+33.23, 18.50' RT
CB-3,TYPE-1
W/ SOLID LOCKING LID
STA. 0+73.29, 13.59' LT
CB-8,TYPE-2-48"
W/ SOLID LOCKING LID
STA. 1+23.22, 41.27' RT \A1;20' CITYEMERGENCYACCESS ESMTFUTURE PAVEMENT AND ROAD WORK BY "AVANA RIDGE" DEVELOPMENT
92 LF 8" PVC @ 2.09%%%
15'x12' POWER ESMT.
SEE PERVIOUS PAVEMENT DETAIL DT-01
SEE PERVIOUS PAVEMENT DETAIL DT-01\A1;25'10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
12" PVC PIPE=391.64
8" SS TOP=389.22
3 STA 16+98.98, 17.11' LT. (SE 172ND ST)
PIPE SEPARATION=2.42'
CB-6-A,CONCRETE INLET
STA. 3+15.79, 7.34' RT
CB-1-A,TYPE 1
STA. 17+95.95, 17.22' LT
3
37 LF 8" PVC @ 2.50%%%
8" PVC PIPE=400.52
8' DETENTION PIPE TOP=399.00
4
STA 1+23.22, 1.48' LT. (DRIVE A)
PIPE SEPARATION=1.52'
8" PVC PIPE=402.42
8' DETENTION PIPE TOP=399.00
5 STA 2+10.17, 10.21' LT. (DRIVE A)
PIPE SEPARATION=3.42'
4
5
CB-11,TYPE-1
STA. 10+47.04, 21.20' LT
95 LF 12" PVC @ 0.47%%%
CB-12,TYPE-1
STA. 10+47.04, 46.26' LT
111 LF 12" PVC @ 5.29%%%
EXISTING CULVERT TO BE REMOVED
12 LF 8" PVC @ 2.00%%%
44 LF 8" PVC @ 2.00%%%
STORM DETENTIOM CLEAN OUT
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
YARD DRAIN
DOWNSPOUT
RAISE TO FINISH GRADE
108TH AVE SE
\A1;26'\A1;30'SE 172ND ST3'X6' WATER ESMT
134 LF 12" PVC @ 1.98%%%
25 LF 12" PVC @ 0.47%%%
50 LF 8" PVC @ 2.00%%%
12 LF 8" PVC @ 6.00%%%
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
CB-13,TYPE-2-48"%%C
STA. 11+42.04, 46.87' LT
30 LF 12" PVC @ 0.60%%%COTTAGE BCOTTAGE A\A1;10'
SDESMT\A1;10'GASESMTCB-9,TYPE-1
W/ SOLID LOCKING LID
STA. 11+05.62, 68.11' LT
COTTAGE CCOTTAGE DCB-14,TYPE-2-48"%%c
W/ SOLID LOCKING LID
STA. 11+71.75, 42.70' LT
CB-15,TYPE-2-48"%%c
W/ SOLID LOCKING LID
STA. 4+12.76, 7.40' RT
72 LF 12" PVC @ 0.50%%%\A1;20'\A1;SD ESMT60 LF 8" PVC @ 0.56%%%
57'UTILITY ESMT
RETAINING WALL DRAIN LINE
STOP SIGN
\A1;20'
\A1;DRIVE AISLE
SEE PAVEMENT SECTIONON SHEET RD-07
\A1;9'\A1;10'
SDESMT
STA. 11+43.01, 47.61' LT
STA. 3+15.83, 7.36' RT
STA. 0+73.64, 1.88' LT
STA. 0+73.32, 13.40' LT
STA. 1+22.75, 9.43' LT
STA. 2+06.59, 16.74' LT
STA. 16+60.08, 9.23' LT
STA. 17+96.77, 16.93' LT
STA. 10+46.85, 46.12' LT
STA. 11+05.93, 67.66' LT
STA. 11+71.49, 41.77' LT
STA. 4+14.03, 8.14' RT
STA. 3+52.74, 9.21' RT
STA. 2+43.95, 9.54' RT
STA. 1+31.38, 20.56' RT
STA. 1+24.10, 41.27' RT
STA. 10+43.59, 21.23' LT
25 LF 12" PVC @ 1.28%%%
96 LF 12" PVC @ 0.52%%%
200 LF 12" PVC @ 1.64%%%
29 LF 12" PVC @ 0.83%%%
72 LF 12" PVC @ 0.58%%%
61 LF 8" PVC @ 0.59%%%35 LF 8" PVC @ 2.80%%%45 LF 8" PVC @ 1.94%%%
73 LF 8" PVC @ 2.23%%%91 LF 8" PVC @ 2.17%%%
11 LF 8" PVC @ 1.50%%%
28 LF 8" PVC @ 1.80%%%
12 LF 8" PVC @ 31.96%%%
56 LF 12" PVC @ 2.07%%%
STA. 16+86.26, 17.86' LT
57 LF 12" PVC @ 1.37%%%
136 LF 12" PVC @ 1.92%%%
51 LF 8" PVC @ 2.33%%%
111 LF 12" PVC @ 5.12%%%
12 LF 12" PVC @ 0.51%%%
12 LF 12" PVC @ 1.00%%%AS-BUILT DRAWINGSthere was a n
approved revision to
replace this with a
concrete inlet per
std plan 200.30. was
this changed?
15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50388.0389.6390.9393.1394.5395.8396.6397.8398.9400.0400.6401.9403.1403.7404.5405.3406.3407.6409.8415.8SE 172ND STSCALE:HOR:
VER:
1"=20'
1"=10'
RIM=
IE=388.06STA. 15+51.14, 16.25' LT.
CB-A16,TYPE 2-60"
W/ SOLID LOCKING LID
IE=388.06 (12"%%C) E
RIM=395.96
STA. 16+60.71, 2.69' RT.
EX CB,TYPE 2-48"
W/ SOLID LOCKING LID
IE=390.84
IE=390.84 (12"%%C) SCB-A17,TYPE 2-48"
RIM=
IE=388.17
STA. 15+58.37, %%132
W/ SOLID LOCKING LID 12 L.F. 12" PVC @ 1.00%%%
RIM=396.22
STA. 16+60.71, 11.19' RT.
CB-16,TYPE 2-48"
CURB INLET, SEE DT-01
IE=390.96 (12"%%C) N
AVANA RIDGE PROPOSED
AVANA RIDGE PROPOSED
RIM=397.74
IE=390.72 (12"%%C) W,E,N
CB-1,TYPE 2-48"
STA. 16+85.07, 17.09' RT.
W/ OPEN GRATE
EXISTING GRADEAT ROAD %%132 PVI EL=410.00PVI STA=19+78.00PVI EL=408.01PVI STA=19+40.005.24%
6.41%
20+00
360
380
400
420
340INTERSECTION, ROAD %%132STA 0+00.00, DRIVE AEL=398.04STA 20+00.00, SE 172ND ST=INTERSECTION, ROAD %%132STA 10+00.00, 108TH AVE SEEL=411.41FG RIM=396.55
{\C251;391.20}*
(12") SE,W *
18 L.F. 12" PVC @ 0.61%{\C7;*}
(12"%%C) E, NW{\C6;*}
391.17{\C6;*}
(12"%%C) W{\C6;*}END PVMTFINISHED GRADEAT ROAD %%132
RIM=401.60
IE=396.60 (12"%%C) W
CB-1-A,TYPE 1
STA. 17+95.95, 17.22' LT.
W/ OPEN GRATE
FINISHED GRADEAT ROAD %%132EXISTING GRADEAT ROAD %%132
5.74%395.76397.20398.45399.48\A1;60' VC
402.94403.85404.873.37%400.41401.26402.104.35%405.965.15%407.24408.53409.846.41%
PVI STA=18+50.00PVI EL={403.78}K=60.83
PVT EL=405.09PVT STA=18+80.00PVT EL=402.77PVT STA=18+20.00PVI EL=406.00PVI STA=19+01.00PVI EL=400.00PVI STA=17+37.72PVI EL=398.00PVI STA=16+88.95EXIST CULVERT
IE=399.22 (12"%%C CMP) E
4.10%
5.24%
IE=390.96 (12"%%C) S EXISTING
102 L.F. 12" PVC @ 2.62%%%
134 L.F. 12" SD @ 1.98%%%
111 L.F. 12" SD @ 5.29%%%395.93397.06398.10399.24400.56401.43402.19403.00404.06404.95406.20407.45408.50410.39IE=387.59 (12"%%C) EIE=387.61 (12"%%C) SE
IE=387.79 (12"%%C) W
RIM=391.04
STA 15+50.75, 17.75' LT
IE=388.05 (12"%%C) E
RIM=390.68STA 15+58.62, 2.22' RT
IE=390.65 (12"%%C) S,W
IE=392.65 (12"%%C) E
RIM=395.82
STA 16+60.57, 2.53' LT
STA 16+60.18, 9.23' RT
IE=390.59 (12"%%C) SIE=390.71 (12"%%C) N
RIM=396.83
STA 16+86.26, 17.86' LT
IE=390.20 (12"%%C) N,W
IE=390.23 (12"%%C) E
RIM=397.68
STA 17+96.77, 16.93' LT
IE=395.91 (12"%%C) W
RIM=401.94
136 L.F. 12" SD @ 1.92%%%
111 L.F. 12" SD @ 5.12%%%
12 L.F. 12" PVC @ 0.51%%%
20 L.F. 12" PVC @ 1.40%
4.33%%%
4.39%%%
3.61%%%
5.05%%%
4.87%%%6.70%%%PVI EL=406.20PVI EL=408.10PVI EL=410.78PVT EL=405.14PVT EL=402.90PVI EL=399.93PVI EL=397.79EL=395.93EL=397.79STA=16+46.00, {\C6;EL=395.54}404.06
STA 16+89.94, SE 172ND ST=TYPE 2-48"%%C
IE=387.89 (12"%%C) NW
360
380
400
420
340
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396211
ROAD AND STORM DRAINAGE PROFILES
AS NOTED
RD-02
2300SCALE: 1" =
0
20'
20'20'40'
CB-1
CB-16
CB-A16
EX-CB
*NOTE
\pxt3;VERTICAL INFORMATION PROVIDED BY AVANA RIDGE APPROVED PROPOSED PLANS AS-BUILT ELEVATIONS MAY VARY. CONTRACTOR TO VERIFY ELEVATION PRIOR TO ORDERING MATERIALS.
\A1;PROPOSED 4.5' R/W DEDICATION
\A1;60'\A1;EX R/W\A1;64.5'SEWER PIPE
WATER PIPE
STORM PIPE
LEGENDSE 172ND ST108TH AVE SE
15+00
TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
NOTE
SCALE: 1" =
0
20'
20'20'40'
CB-1-A
DRIVE A
RAISE LID TO FINISHED GRADE AND REPLACE W/ SOLID LOCKING LID EXISTING CULVERT TO BE REMOVED
EXISTING CULVERT TO BE REMOVED
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
134 LF 12" PVC
3'X6' WATER ESMT
111 LF 12" PVC
12 LF 12" PVC \A1;26'CB-A17
18 LF 12" PVC
102 LF 12" PVC 111 LF 12" PVC
136 LF 12" PVC
12 LF 12" PVC
20 LF 12" PVC
AS-BUILT DRAWINGS
360
380
400
420
0+00 0+50 1+00 1+50 2+00398.3398.5401.4403.1403.4404.5406.3408.3409.8340
CB-1,TYPE 2-48"
SEE SE 172ND ST PROFILE,
CB-2,TYPE 2-54"
RIM=400.65
IE=394.89
STA. 0+73.24, 1.57' LT.
(8"%%C) W
IE=391.50 (36"%%C) N
CONTROL STRUCTURE
CB-3,TYPE 1
RIM=400.56
IE=395.61
W/ SOLID LICKING LID
(8"%%C) N, E
12 L.F. 8" PVC @ 6.00%%%
MODULAR WETLAND OUTFALL
RIM= 402.55
STA. 1+01.78, 13.59' LT.
MODULAR WETLAND INTAKE
IE=400.11
STA. 1+11.79, 13.59' LT.
(8"%%C) N
CB-8,TYPE 2-48"
SEE COURT YARD, RD-06
STA. 1+23.22, 41.27' RT.
RIM=404.86
IE=391.50
STA. 1+33.23, 18.50' RT.
(36"%%C) N
12 L.F. 8" PVC @ 2.00%%%
CB-4,TYPE 1
RIM=403.05
IE=400.35
STA. 1+23.22, 9.22' LT.
(8"%%C) N
CB-5,CONCRETE INLET
RIM=406.08
IE=402.27
STA. 2+07.40, 16.19' LT.
(6"%%C) E,S
29 L.F. 8" PVC @ 4.83%%%
IE=397.20 (8"%%C) S
RIM= 402.55
CROSSING #1
STA. 1+23.31, 21.98' RT.12" SD IE=400.88
8" SS CROWN=399.01
SEPARATION=1.87'
IE=402.10 (8"%%C) E
50 L.F. 8" PVC @ 2.00%%%
SHEET RD-02
FINISHED GRADEAT DRIVE AISLE %%132
EXISTING GRADEAT DRIVE AISLE %%132
DRIVE AHOR:
VER:399.29400.78402.08403.38404.43405.27406.19407.30PVI EL=400.00PVI STA=0+60.00PVI EL=404.00PVI STA=1+37.00PVI EL=405.83PVI STA=1+92.00SCALE:1"=20'
1"=10'STA 0+00.00, DRIVE A=INTERSECTION, ROAD %%132STA 16+89.94, SE 172ND STEL=398.04R/W LINEIE=400.35 (8"%%C) E,SPVI STA=0+32.50PVI EL=398.0636 L.F. 4" PVC @ 8.97%%%
IE=391.50 (12"%%C) S
STA. 0+73.29, 13.59' LT.
CB-10,TYPE 2-48"
W/ SOLID LOCKING LID
96"%%C DETENTION PIPE
3.33%
4.44%
INLET-1
STA. 1+27.14, 4.5 LT
RIM=403.40
INLET-2
STA. 1+77.43, 5.5 RT
RIM=405.46
INLET-4
STA. 1+87.14, 4.5 LT
RIM=405.58
INLET-3
STA. 1+77.47 15.5 RT
RIM=406.51
FINISHED GRADEAT DRIVE AISLE %%132EXISTING GRADEAT DRIVE AISLE %%132
5.19%
7.05%
92 L.F. 8" PVC @ 2.09%%%
57 L.F. 12" SD @ 1.37%
STA 0+73.64, 1.88' LT
IE=391.49 (12"%%C) NIE=392.00 (8"%%C) W
RIM=400.77
IE=391.36 (12"%%C) S
STA 0+73.32, 13.40' LT
IE=395.69 (8"%%C) N,E
RIM=400.63
12 L.F. 8" PVC @ 31.96%%%
STA 1+01.07, 13.59' LT
IE=396.18 (8"%%C) SRIM=402.81
STA 1+11.93, 11.50' LT
IE=400.21 (8"%%C) N
RIM=402.81 STA 2+06.59, 16.74' LT
IE=402.42 (6"%%C) E
RIM=405.76
IE=402.35 (6"%%C) S
IE=400.37 (8"%%C) N,E,S
RIM=403.02
STA 1+22.75, 9.43' LT
IE=402.01 (8"%%C) E
IE=391.57 (36"%%C) N
RIM=405.11
STA 1+31.38, 20.56' RT
399.31400.58402.19403.50404.50405.23406.17407.34397.7928 L.F. 8" PVC @ 1.80%%%
51 L.F. 8" PVC @ 2.33%%%
11 L.F. 8" PVC @ 1.50%%%
56 L.F. 12" SD @ 2.07%%%
91 L.F. 8" PVC @ 2.17%%%EL=397.79PVI EL=398.43PVI EL=399.81PVI EL=404.04PVI EL=405.873.33%%%
5.49%%%
5.02%%%
CB-10A,RIM=403.37
RIM=405.39
RIM=405.48
RIM=405.51
360
380
400
420
340
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396212
ROAD AND STORM DRAINAGE PROFILES
AS NOTED
RD-03
2301CB-6
CB-5
CB-8
CB-2 CONTROL STRUCTURE
CB-4
CB-3CB-1
29 LF 8" PVC
12 LF 8" PVC
CB-11
EX-CB
44 LF 8" PVC
NOTE
SEWER PIPE
WATER PIPE
STORM PIPE
LEGEND
DRIVE A
SCALE: 1" =
0
20'
20'20'40'SEE SHEET RD-04REFERENCE LINECOTTAGE DCOTTAGE ASEE SHEET RD-04REFERENCE LINEDRIVE A
20' CITY EMERGENCY ACCESS ESMT
\A1;20'\A1;DRIVETOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
CHECK DAM, SEE DETAIL SHEET DT-01
FILTERRA 6'X10'
MODULAR WETLAND
12 LF 8" PVC
36 LF 6" PVC
15' UTILITY ESMT
96"%%C DETENTION PIPE
20' CITY EMERGENCY ACCESS ESMT
FOR TRASH INCLOSURE ROOF DRAIN
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
92 LF 8" PVC
57 LF 12" PVC
SE 172ND ST
50 LF 8" PVC
45 LF 8" PVC
12 LF 8" PVC 91 LF 8" PVC
28 LF 8" PVC
12 LF 8" PVC
56 LF 12" PVC
51 LF 8" PVC
AS-BUILT DRAWINGSthe profile view calls
this out as 11 lf -
verify
the connection from
the tank to the outlet
control structure
should be 36-in
minimum per section
5.1.2.1 of the swdm.
was this changed to
12-in or is this an
error?
this is noted as 6-in in
plan view
155.1 ft
94.8 ft
75.0 ft
2+50 3+00 3+50 4+00 4+50 5+00411.0411.6411.6411.3411.9411.9411.8412.5412.6413.3413.4CB-6,CONCRETE INLET
RIM=407.90
IE=404.40
STA. 2+43.92, 9.25' RT.
(6"%%C) N,S
CB-7,CONCRETE INLET
RIM=409.85
IE=406.35
STA. 3+52.80, 9.25' RT.
(6"%%C) S
44 L.F. 8" PVC @ 2.00%%%
IE=405.85 (8"%%C) W
IE=403.15 (8"%%C) W,E
FINISHED GRADEAT DRIVE AISLE %%132
EXISTING GRADEAT DRIVE AISLE %%132
DRIVE A
SCALE:HOR:
VER:
1"=20'
1"=10'360
380
400
420
408.11408.66409.20409.57409.95410.66411.37409.8407.30PVI EL=407.83PVI STA=2+37.00PVI EL=409.31PVI STA=3+05.00PVI EL=409.83PVI STA=3+46.00440
STA 5+19.12, DRIVE A=INTERSECTION, ROAD %%132STA 12+13.23, 108TH AVE SEEL=413.70R/W LINESTA 4+78.7996"%%C DETENTION PIPE
1.91%PVI EL=413.52PVI STA=4+75.80PVI EL=413.19PVI STA=4+92.14412.08412.79413.50413.34
2.18%
-2.01%
INLET-5
STA. 2+48.42, 7.5 LT
RIM=408.23
INLET-6
STA. 2+53.42, 2.5 RT
RIM=408.14
INLET-7
STA. 2+98.59, 6.9 LT
RIM=409.29
FINISHED GRADEAT DRIVE AISLE %%132EXISTING GRADEAT DRIVE AISLE %%132
CB-6-A,TYPE 1
RIM=409.30
IE=404.93
STA. 3+15.79, 7.34' RT.
(8"%%C) E,W
IE=406.30 (6"%%C) S
2.84%
1.27%
37 L.F. 8" PVC @ 2.50%%%71 L.F. 8" PVC @ 2.50%%%
IE=405.85 (12"%%C) E
CB-15,TYPE 2-48"%%C
RIM=411.58
IE=406.19
STA. 4+12.76, 7.40' RT.
(12"%%C) W,SE
W/SOLID LOCKING LID
60 L.F. 12" SD @ 0.56%%%
6" MINIMUM SEPERATION BETWEEN STORM PIPE AND WATER MAIN AT CROSSING
TRENCH DAM, SEE DETAIL THIS SHEETTRENCH DAM, SEE DETAIL THIS SHEETTRENCH DAM, SEE DETAIL THIS SHEETTRENCH DAM, SEE DETAIL THIS SHEET
407.34408.20408.78409.04409.69410.12410.68411.31411.93412.70413.37413.27PVI EL=407.93PVI EL=409.21PVI EL=410.01PVI EL=413.37PVI EL=413.291.88%%%
2.59%%%
1.95%%%
IE=403.79 (6"%%C) N
IE=403.86 (6"%%C) S
RIM=407.98
STA 2+43.95, 9.54' RT
IE=403.30 (8"%%C) W,E
IE=406.58 (6"%%C) S
IE=406.82 (12"%%C) E
RIM=409.91
STA 3+52.74, 9.21' RT
IE=405.91 (8"%%C) W
IE=407.18 (12"%%C) W,SE
RIM=411.35
STA 4+14.03, 8.14' RT
IE=404.93 (8"%%C) E,W
IE=405.94 (6"%%C) S
STA 3+15.83, 7.36' RT
RIM=409.36
73 L.F. 8" PVC @ 2.23%%%
61 L.F. 12" SD @ 0.59%%%35 L.F. 8" PVC @ 2.80%%%
45 L.F. 8" PVC @ 1.94%%%
RIM=408.25RIM=408.36 RIM=409.18
360
380
400
420
440
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396213
ROAD AND STORM DRAINAGE PROFILES
AS NOTED
RD-04
2302CB-7
CB-6
CB-5
36 LF 6" PVC
COTTAGE ADRIVE A 108TH AVE SE
44 LF 8" PVC DRIVE A
SCALE: 1" =
0
20'
20'20'40'
\A1;30'
\A1;R/W
PROPOSED 15.5'R/W DEDICATION
SEE SHEET RD-03REFERENCE LINE
SEE SHEET RD-03
REFERENCE LINE
NOTE
SEWER PIPE
WATER PIPE
STORM PIPE
LEGEND
TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
CHECK DAM, SEE DETAIL SHEET DT-01
15'x12' POWER ESMT.
CB-6-A
71 LF 8" PVC 37 LF 8" PVC
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
92 LF 8" PVC
15' WATER ESMT
60 LF 12" PVC
COTTAGE B\A1;24'\A1;DRIVE AISLE30 LF 12" PVC\A1;20' CITYEMERGENCYACCESS ESMT72 LF 12" PVC
CB-13
CB-15
\A1;20''\A1;SD ESMTTRENCH DAM COMPACTED GLACIAL TILL, CDF OR SIMILAR LOW PERMEABLE MATERIAL
TRENCH SIDEWALL
6"
1' MIN FROM PAVING SURFACE
PAVEMENT
SCALE: NTS
TRENCH DAM DETAIL
STORM OR WATER PIPE
INSTALL TRENCH DAM PER DETAIL, THIS SHEET
INSTALL TRENCH DAM PER DETAIL, THIS SHEET
INSTALL TRENCH DAM PER DETAIL, THIS SHEET
\A1;15'WATERESMTRESERVOIR COARSE MATERIAL FOR TRENCH BACKFILL UNDER PERVIOUS PAVEMENT
WATER MAIN UNDER CHECK DAMS TO BE INSTALLED PER DETAIL ON SHEET DT-01
29 LF 12" PVC
72 LF 12" PVC
35 LF 8" PVC73 LF 8" PVC
45 LF 8" PVC
91 LF 8" PVC
61 LF 12" PVC
AS-BUILT DRAWINGS85.0 ft
70.0 ft
31.1 ft
19.9 ft
{412}
{412}
{408}
{410}
S
T
PVPV VV
SIGNS
GV
S
S
12" D.I. WATER MAIN12" D.I. WATER MAIN 12" D.I. WATER MAIN
8" D.I.
WATER MAIN 12" D.I. WATER MAIN8" D.I.WA MAIN{404}{408}
{410}{410}{410}{412}{414}
{416}
T 20+005+00400
420
440
10+0010+5011+0011+5012+0012+50 411.4411.6412.2412.2412.6412.8413.1413.4413.8414.3380108TH AVE SESCALE:HOR:
VER:
1"=20'
1"=10'410.65411.09411.57412.03412.22412.41412.68413.00413.33413.65PVI EL=412.49PVI STA=11+60.56PVI EL=412.01PVI STA=10+98.42PVI EL=410.70PVI STA=10+29.82EXISTING GRADEAT ROAD %%132EXISTING GRADEAT SAWCUT LINE FINISHED GRADE
AT ROAD FLOWLINEAPPROXIMATE
400
420
440
380 STA 12+13.23, 108TH AVE SE=INTERSECTION, ROAD %%132STA 5+19.12, DRIVE AEL=413.70STA 10+00.00, 108TH AVE SE=INTERSECTION, ROAD %%132STA 20+00.00, SE 172ND STEL=411.410.76%1.92%0.96%
1.30%
FINISHED GRADEAT SAWCUT LINEEXISTING GRADEAT ROAD %%132
CB-11,TYPE 1
RIM=410.56
IE=407.36
STA. 10+47.04, 21.20' LT.
(12"%%C) W
CB-12,TYPE 1
RIM=410.70
IE=407.24 (12"%%C) N,E
25 L.F. 12" PVC @ 0.47%%%
STA. 10+47.04, 46.26' LT.
CB-13,TYPE 2-48"%%C
RIM=412.00
IE=406.79
STA. 11+42.04, 46.87' LT.
(12"%%C) N,S
95 L.F. 12" PVC @ 0.47%%% (PRIVATE)
CB-14,TYPE 2-48"%%C
RIM=412.51
IE=406.61
STA. 11+71.75, 42.70' LT.
(12"%%C) S,NE
30 L.F. 12" SD @ 0.60% (PRIVATE)
SEE DRIVE A PROFILE
CB-15
SHEET RD-04
W/SOLID LOCKING LID
72 L.F. 12" SD @ 0.58% (PRIVATE)413.55413.07412.80412.51412.43412.07411.68411.46410.84PVI EL=412.64PVI EL=412.04PVI EL=410.96EL=413.27EL=410.42STA 11+43.01, 47.61' LT
IE=407.84 (12"%%C) N,S
RIM=411.62
STA 10+43.59, 21.23' LT
IE=408.68 (12"%%C) W
RIM=411.21
STA 10+46.85, 46.12' LT
IE=408.36 (12"%%C) E
RIM=410.63
STA 11+71.49, 41.77' LT
IE=407.60 (12"%%C) S,NW
RIM=413.23
IE=408.34 (12"%%C) N
0.97%%%1.57%%%1.81%%%
1.19%%%
96 L.F. 12" PVC @ 0.52%%% (PRIVATE)29 L.F. 12" SD @ 0.83% (PRIVATE)72 L.F. 12" SD @ 0.58% (PRIVATE)
25 L.F. 12" PVC @ 1.28%%%
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396214
ROAD AND STORM DRAINAGE PROFILES
AS NOTED
RD-05
2303CB-9
NOTE
SEWER PIPE
WATER PIPE
STORM PIPE
LEGEND
SCALE: 1" =
0
20'
20'20'40'COTTAGE BCOTTAGE CDRIVE A \A1;30'\A1;EX R/WPROPOSED 15.5'R/W DEDICATION\A1;22'TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
10+0011+0012+0013+00
3+0020+00\A1;22.7'CB-11
CB-12
SE 172ND ST
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY108TH AVE SE25 LF 12" PVC
\A1;10'SDESMTCB-13
95 LF 12" PVC
30 LF 12" PVC
72 LF 12" PVC
\A1;20'\A1;SD ESMT
N=166681.99
E=1303056.92
N=166622.67
E=1303017.93
CB-14 29 LF 12" PVC 25 LF 12" PVC
96 LF 12" PVC72 LF 12" PVC
AS-BUILT DRAWINGSthere was a n
approved revision to
replace this with a
concrete inlet per
std plan 200.30. was
this changed?
360
380
400
420
440
0+00 0+50 1+00 1+50 2+00 2+50 3+00403.5406.3408.1409.2410.1410.3409.6410.0410.5411.3412.0412.9412.4360
380
400
420
440
CB-4,TYPE 1
STA. 1+23.22, 9.22' LT.
CB-8,TYPE 2-48"
RIM=410.10
IE=401.35
STA. 1+23.22, 41.27' RT.
(8"%%C) W
IE=402.95 (12"%%C) E
COURT YARDSCALE:HOR:
VER:
1"=20'
1"=10'
APPROXIMATE
EXISTING GRADE
FINISHED GRADE
(DRIVE A)(DRIVE A)%%132 108TH AVE SE%%132 DRIVE APROPERTY LINER/W LINE96"%%C DETENTION PIPEPER STD. 235.00
EXISTING GRADE
RIM=403.05
IE=400.35 (8"%%C) N
IE=400.35 (8"%%C) E,S
0+41.24
CB-9,TYPE 1
RIM=411.51
IE=406.51
STA. 11+05.62, 68.11' LT.
(12"%%C) W
SOLID LOCKING LID
(108TH AVE SE)
200 L.F. 12" PVC @ 1.78%%%
IE=400.37 (8"%%C) N,E,S
STA 1+22.75, 9.43' LTRIM=403.02 STA 1+24.10, 41.27' RTIE=401.56 (8"%%C) W
IE=403.13 (12"%%C) E
RIM=410.05
STA 11+05.93, 67.66' LTIE=407.42 (4"%%C) S
RIM=411.11
IE=406.42 (12"%%C) W
200 L.F. 12" PVC @ 1.64%%%
50 L.F. 8" PVC @ 2.00%%%51 L.F. 8" PVC @ 2.33%%%
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396215
ROAD AND STORM DRAINAGE PROFILES
AS NOTED
RD-06
2304CB-8
CB-2 CONTROL STRUCTURE
CB-4
CB-3
200 LF 12" PVC
NOTE
SEWER PIPE
WATER PIPE
STORM PIPE
LEGEND
FILTERRA 6'X10'
MODULAR WETLAND
108TH AVE SECOTTAGE ACOTTAGE DCOTTAGE CCOTTAGE BSCALE: 1" =
0
20'
20'20'40'
DRIVE A
TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESEPLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING,INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.)ASSUMES NO LIABILITY AS TO THE ACCURACY ANDCOMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUNDBETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED INTHE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE
TOPOGRAPHIC DISCLAIMER
CB-10
CB-9
CB-11
\A1;10'
SDESMT
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
50 LF 8" PVC
95 LF 12" PVC
CB-12
68 LF 12" PVC
29 LF 12" PVC
96 LF 12" PVC
200 LF 12" PVC
51 LF 8" PVC
AS-BUILT DRAWINGS
\A1;0.5'\A1;30' EX R/W
6'PARKING
SCALE: 1"=5'
1.5%
2.0%
R/W
R/W %%132\A1;82.5' R/W
EX R/W
\A1;5.5'%%P\A1;EX SIDEWALK \A1;8'%%P
\A1;0.5'\A1;22'%%P EX PVMT\A1;37'%%P EX R/W
R/W
\A1;15.5' R/W DEDICATION\A1;10.5'\A1;8'\A1;SIDEWALK \A1;4.5' %%P\A1;TRAVEL LANE\A1;5'BIKELANE
\A1;VARIES
\A1;VARIES\A1;6'\A1;8" ACP CLASS B
6" CRUSHED SURFACING TOP COURSE
SUITABLE NON-YIELDING SUB-GRADE
6" VERTICAL CURB AND GUTTER PER COR STD PLAN 101 4" CEMENT CONCRETE WALK PER COR STD PLAN 102, TYP
\pxql;6" COMPACTED DEPTH CRUSHED SURFACING BASE COURSE
108TH AVE SESTA 11+25.00SAWCUTWESTEAST
\A1;6'
\A1;30' EX R/W
SCALE: 1"=5'
2.0%R/W %%132\A1;64.5' R/W
EX R/W\A1;30'%%P EX R/W
R/W
\A1;4.5' R/W
\A1;DEDICATION
\A1;18' PVMT \A1;0.5'\A1;8'\A1;PLANTER \A1;6'\A1;SIDEWALK
1.5%
\A1;8' PVMT
2.0%
R/W
\A1;0.5'\A1;5.5'\A1;SIDEWALK\A1;16'
\A1;8" ACP CLASS B
6" CRUSHED SURFACING TOP COURSE
SUITABLE NON-YIELDING SUB-GRADE
6" VERTICAL CURB AND GUTTER PER COR STD PLAN 101, TYP4" CEMENT CONCRETE WALK PER COR STD PLAN 102, TYP
\pxql;6" COMPACTED DEPTH CRUSHED SURFACING BASE COURSE
SE 172ND STSTA 18+25.00\A1;VARIES
RETAINING WALLSEE SHEET GR-01 FOR WALLHEIGHT
\A1;VARIES
\A1;VARIES\A1;VARIESSOUTHNORTH
1.5%
SCALE: 1"=5'
DRIVE A
STA 4+50.00PVMT %%132
2.0%
\A1;10'
\A1;TRAVEL LANE
2.0%
\A1;10'
\A1;TRAVEL LANE \A1;0.5'\A1;20'
\A1;PARKING\A1;0.5'\A1;5'2.0%
ZERO HEIGHT CONCRETE CURB PER DETAIL SHOWN ON SHEET DT-034" CEMENT CONCRETE WALK PER COR STD PLAN 102, TYP
\pxql;6" COMPACTED DEPTH CRUSHED SURFACING BASE COURSE
\A1;VARIES
\A1;VARIES
6" VERTICAL CURB AND GUTTER PER COR STD PLAN 101, TYP
\A1;VARIES
\A1;VARIES
6" PERVIOUS PAVEMENT PER DETAIL SHOWN ON SHEET DT-01 \A1;3'SOUTHNORTH
1.5%
SUITABLE NON-YIELDING SUB-GRADE
\A1;2" ACP
3" ATB
5" AGGREGATE SUB-BASE
SCALE: 1"=5'DRIVE ASTA 1+00.00PVMT %%132
2.0%
\A1;10'
\A1;TRAVEL LANE
2.0%
\A1;10'
\A1;TRAVEL LANE \A1;0.5'\A1;5'\A1;SIDEWALK
SUITABLE NON-YIELDING SUB-GRADE
6" VERTICAL CURB AND GUTTER PER COR STD PLAN 101, TYP
\A1;0.5'
4" CEMENT CONCRETE WALK PER COR STD PLAN 102, TYP
\pxql;6" COMPACTED DEPTH CRUSHED SURFACING BASE COURSE
\A1;VARIES
\A1;VARIES
\A1;2" ACP
3" ATB
\A1;VARIES
RETAINING WALLSEE SHEET GR-01 FOR WALLHEIGHT
\A1;VARIES
\A1;VARIES
EAST
WEST
1.5%
5" AGGREGATE SUB-BASE
SCALE: 1"=5'
DRIVE A
CMP LIMIITED COVERPVMT %%132
2.0%
\A1;10'
\A1;TRAVEL LANE
2.0%
\A1;10'
\A1;TRAVEL LANE \A1;0.5'\A1;5'\A1;SIDEWALK
SUITABLE NON-YIELDING SUB-GRADE
6" VERTICAL CURB AND GUTTER PER COR STD PLAN 101, TYP
\A1;0.5'
4" CEMENT CONCRETE WALK PER COR STD PLAN 102, TYP
\pxql;6" COMPACTED DEPTH CRUSHED SURFACING BASE COURSE
\A1;VARIES
\A1;VARIES
\A1;5" PORTLAND CONCRETE CEMENT
\A1;VARIES
RETAINING WALLSEE SHEET GR-01 FOR WALLHEIGHT
\A1;VARIES
\A1;VARIES
EAST
WEST
1.5%
4" CRUSHED ROCK BASE
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396216
ROAD SECTIONS
AS NOTED
RD-07
2305TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
AS-BUILT DRAWINGSverify if this was
utilized. it was
crossed out on
the revision
plan that was
submitted.
DETENTION PIPE - TYPICAL PROFILE
SCALE: 1"=10'
0.5' SEDIMENT STORAGE ACCESS LADDER, TYP36"%%C CMP36"%%C CMP
2 L.F. 36"%%C SD @ 0.00%%%
96"%%C CMP DETENTION PIPE AT0.00%LENGTH VARIES, SEE PLAN
36"%%C ACCESS MANWAY, TYP FINISHED GRADE VARIES, SEE PLAN AND PROFILE
36"%%C CMP
36"%%C ACCESS MANWAY, TYP
391.06
391.49
BOTTOM OF PIPE EL={\C6;391.00}
BEGIN LIVE STORAGE EL={\C6;391.50}
2 YR WSE={\C6;397.12}
10 YR WSE={\C6;397.92}
50 YR WSE={\C6;398.47}
100 YR WSE={\C6;398.48}
TOP OF LIVE={\C6;398.50}
TOP OF PIPE EL={\C6;399.00}
397.67
398.50
398.54
398.54
398.73
399.06
DETENTION PIPE - TYPICAL SECTIONSCALE: 1"=5'
0.5' SEDIMENT STORAGE
\A1;2'\A1;2'
FOR 2 OR MORE ADJACENT PIPES
FINISHED GRADE VARIES, SEE PLAN AND PROFILE \pxql;ACCESS MANWAY PER COR STD PLAN 235.10, DETENTION TANK ACCESS DETAIL, SEE PLAN FOR LOCATIONS, TYP
0.5' FREE BOARD
8' %%C DETENTION TANK PERCOR STD PLAN 235.00NOTE: CMP 10 GAGE ORBETTER.\pxql;36"%%C CMP
2 YR WSE={\C6;397.12}
10 YR WSE={\C6;397.92}
50 YR WSE={\C6;398.47}
100 YR WSE={\C6;398.48}
TOP OF LIVE={\C6;398.50}
TOP OF PIPE EL={\C6;399.00}
BEGIN LIVE STORAGE EL={\C6;391.50}
BOTTOM OF PIPE EL={\C6;391.00}
391.06
391.49
397.67
398.50
398.54
398.54
398.73
399.06
\A1;2' MIN\A1;2' MINEL=387.50
1/2"%%C ORIFICE
RESTRICTOR PLATE
IE=389.50
IE=391.50 (36"%%C)
RISER EL=398.50 50 YR WSEL=398.47\A1;6" MINDISCHARGE TO CB-1 FROM DETENTION PIPE
IE=391.50 (12"%%C)CONTROL STRUCTURE CB-2SCALE: 1"=2'
SHEAR GATE WITH CONTROL ROD FOR CLEANOUT/DRAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER)
4" ELBOW RESTRICTORSEE DETAIL, TYP
RIM EL=400.65
1-1/8"%%C ORIFICE
IE=397.23
\A1;54"%%C MIN
{\LELEVATION}
\pxql;PIPE SUPPORTS SEE NOTE 4
\A1;18"
FROM CB-3
IE=394.89 (8"%%C)
1/2"%%C ORIFICE
IE=398.00
IE=397.28
IE=398.22
IE=391.36 (12"%%C)IE=391.49 (36"%%C)
RIM EL=400.81
RISER EL=398.73
{\LPLAN}
FROM DETENTION PIPE
36"%%C SD
12"%%C SD
SHEARGATE
\A1;82\U+00B0
6" MIN.2" MIN.6"MAXPLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED
REMOVABLE WATERTIGHT COUPLING OR FLANGE8"%%C ELBOW
%%UELBOW RESTRICTOR
TO CB-1
54"%%C MIN
ACCESS4" ELBOW RESTRICTORSEE DETAIL, TYP
8"%%C SD
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396217STORM DRAINAGE DETENTION PLANAS NOTED
SD-01
2306DETENTION PIPE SUMMARY CHART
STORM EVENT LIVE STORAGE VOLUME (CF)RELEASE RATE (CSF)
REQUIRED DESIGNED AS-BUILT REQUIRED DESIGNED AS-BUILT
2 YR 19,555 19,962 20,270 0.041 0.036 0.036
10 YR 22,267 22,827 22,267 0.074 0.058 0.0573
100 YR 22,352 22,894 22,352 0.098 0.093 0.092
NOTE
\pxi-2,l2,t2;1.SEE APPROVED BUILDING PERMIT B17004182 FOR ADDITIONAL CONSTRUCTION DETAILS FOR DETENTION PIPE INSTALLATION.AS-BUILT DRAWINGSplease verify/update
these numbers
1.EXISTING 108TH AVE SE FRONTAGE OVERHEAD POWER TO BE REMOVED ANDRELOCATED UNDERGROUND PER REQUIREMENTS SET FORTH BY PUGET SOUND ENERGYAND CITY OF RENTON.2.MAINTAIN AND REUSE EXISTING STREETLIGHT ON EXISTING UTILITY POLE BEINGRELOCATED 22 FEET NORTHWEST3.REFER TO ELECTRICAL PLAN FOR LOCATION OF ONSITE ELECTRICAL ROUTING.
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18GAS LINE
UNDERGROUND POWER LINE
POWER VAULT
LEGEND
SEWER PIPE
WATER PIPE
STORM PIPE
DRAIN PIPE
STORM DRAIN CLEAN OUT
DOWNSPOUT
G
NOTE
POST INDICATOR VALVE
SIDE SEWER CLEAN OUT
STORM DETENTION
ROOFLINE
FENCE
SCALE: 1" =
0
20'
20'20'40'
R-396218COMPOSITE UTILITY PLAN1"=20'
UT-01
2307P
10' LANDSCAPE BUFFER
15' WATER ESMT
4.5' R/W DEDICATION
CATCH BASINRIM=395.85'IE=392.75'(E,12"CMP)IE=391.23'(W,12"CMP)
DRIVE A
SSMHRIM=400.75'IE=391.23'(E,6"PVC)IE=391.13'(W,8"PVC)CULVERTIE=396.24'(12"CONC)6'x10' MODULAR WETLAND
96"%%C DETENTION PIPE PER STD. 235.00
STREET LIGHT CABINET
TYPE I JUNCTION BOX CABINET W/ CONCRETE PAD
NEW ROADWAY LIGHT POLE
NEW PEDESTRIAN LIGHT POLE
15'x12' POWER ESMT.
ELECTRICAL SERVICE
10' LANDSCAPE BUFFER
P
SSMH RIM=411.49'IE=401.53 (N,E 8"%%C PVC)RAISE TO FINAL GRADECENTER OF MANHOLELIES 3.3' E. OF PROPERTYLINE
SE 172ND ST108TH AVE SE
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
15.5' R/W DEDICATION
\A1;20'
\A1;DRIVE AISLE
22'PVMT
30'EX R/W\A1;24'\A1;DRIVE AISLE22.2'PVMT
\A1;10'
SDESMT
\A1;18'\A1;PVMT30'EX R/W\A1;26'\A1;PVMT8'PVMT60'EX R/W\A1;20' CITYEMERGENCYACCESS ESMT\A1;10'GASESMT\A1;10'
SDESMT
\A1;20' CITY
EMERGENCYACCESS ESMT
TBR
TBR
AS-BUILT DRAWINGS
SCALE: NTSPERVIOUS PAVEMENT CHECK DAM DETAIL\A1;38"\A1;16"
\A1;8"CHECK DAM SPACING VARIES SEE RD-01 FOR SPACING
6"MIN\A1;16"\pxql;COMPACTED SUBGRADE OR BASE
\pxql;6" RUNOFF TREATMENT COURSE
COMPACTEDSUBGRADE
\pxql;24" RESERVOIR COURSE
\pxql;2" LEVELING COURSE
6" PERVIOUS PAVEMENT WEARING COURSE
\pxql;CHECK DAM, NON-PERMEABLE MATERIAL 1' WIDE TYP. DAM TO EXTEND INTO NATIVE MATERIAL 1' ON EACH SIDE, AND 6" EMBEDMENT.
\pxql;6" SLOTTED DRAIN PVC PER ASTM D1785 SCH 40 \A1;1"MIN\A1;35" MAX\pxql;6" MIN SEPARATION BETWEEN BOTTOM OF CHECK DAM AND TOP OF WATER OR STORM PIPES
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396219
NOTES AND DETAILS
AS NOTED
DT-01
2308RIM=402.55
IE=397.20
IE=400.11 SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITHTHE CITY OF RENTON PLAN REVIEWER.2.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE ANDMUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BYTHE CITY OF RENTON PUBLIC WORKS DEPARTMENT.3.THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ONFILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVALFROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION.4.A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.5.DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTALCONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTONPUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS.6.ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, ANDTHEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITEEROSION HAS PASSED.7.ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALLCONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITYSECTION.8.GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVEDSTANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS DEPARTMENT,SURFACE WATER UTILITY SECTION.9.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THISSHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL ASPLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THEPIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS {“ }C{”}, WITHTHE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT ANDSTRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES OVER AND UNDERPVC PIPE.10.GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE.11.STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEETFROM THE TOP OF ANY CHANNEL BANK.12.ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL.13.OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLYAPPROVED BY CITY OF RENTON PLANNING/ BUILDING/ PUBLIC WORKS ADMINISTRATOR.14.ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCKPLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS:4 - 8 INCH ROCK / 40 - 70% PASSING;2 - 4 INCH ROCK / 30 - 40% PASSING; ANDLESS THAN 2 INCH ROCK / 10 - 20% PASSING.15.ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESSAPPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIEDAS-BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION.16.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OFTHE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER,THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THESYSTEM PROVIDED DURING CONSTRUCTION.17.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVEEQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, ANDTO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHINTHE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLANAPPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOTSTANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY.“ ”
NOTES
1.CHECK DAM OR INTERCEPTOR REQUIREDFOR LONGITUDINAL SLOPES > 2%.2.SPACE CHECK DAMS BASED ON SLOPETO ACHIEVE DESIGN AVERAGE PONDINGDEPTH BEFORE OVERTOPPING DAM.3.CALCULATE STORAGE VOLUME BETWEENCHECK DAMS BASED ON CHECK DAM HEIGHTAND SLOPE FOR MODELING.4.LONGITUDINAL SLOPE MAXIMUM VARIESWITH WEARING COURSE MATERIAL PERSTANDARD DETAIL NDT-11 AND NDP-12.
5.00% MAX
AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396220
NOTES AND DETAILS
AS NOTED
DT-02
231/AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396221
NOTES AND DETAILS
AS NOTED
DT-03
2310\A1;20'
\A1;8' MIN \A1;8' MIN
NO
PARKING
NOT TO SCALEPARKING SPACE DETAILVAN-ACCESSIBLE AND HANDICAPRESERVEDPARKING
STATE DISABLED
PARKING PERMIT
REQUIRED
VANACCESSIBLE
NOT TO SCALEPARKING SIGN - "VAN ACCESSIBLE"\A1;60" FROM FLOOR\A1;OF PARKING SPACENOT TO SCALECONCRETE SIDEWALK DETAIL1"
NOT TO SCALEVERTICAL CONCRETE CURB DETAIL\A1;6"\A1;6"NOT TO SCALECONCRETE SIDEWALK FOR TRAFFICNOT TO SCALEASPHALT PAVEMENT DRIVE AISLESPAINT WHITE LOGO AND 4"BORDER ON LIGHT BLUE FIELD(3"x3") TYPSEE STANDARD DETAIL
\pxql;SIDEWALK OR PLANTER
12" WHITE PAINT"NO PARKING"
HANDICAP SIGNDIMENSION CRITERIA
\pxqc;SIGN LOCATION \pxqc;HEIGHT REQUIREMENT
\pxql;MIN. 60" TO BOTTOM OF SIGN\pxql;ON POLE
\pxql;MIN. 36" TO BOTTOM OF SIGN\pxql;ON BUILDING
\pxql;PLACE VAN-ACCESSIBLE SIGN UNDER HC SIGN (SEE PLAN)
\A1;2'\A1;2'\pxql;SEE PARKING SIGN DETAIL\pxql;COMPACT SUBGRADE TO 95% AND REMOVE ANY LOOSE MATERIAL
\pxql;4" AGGREGATE BASE
\pxql;4" CONCRETE SIDEWALK
\A1;2% MAX
\A1;R=1/2" (TYP)
\A1;SLOPE
\pxql;PAVEMENT SURFACE
REFLECTIVE SIGN CONSTRUCTED OF ALUMINUM
SIGN TO BE CENTERED AT THE INTERIOR OF END OF PARKING SPACE
AREA OF SIGN TO BE ALUMINUM A MIN 70 SQ IN
GREEN
WHITE
BLUE
DESIGNATED FOR "VAN ACCESSIBLE" WHERE APPROPRIATE MUST BE MOUNTED AT 60" HIGH MIN FROM FLOOR OF PARKING SPACE FOR FREE STANDING SIGNS WHITE
GREEN
\pxql;COMPACT SUBGRADE TO 95% AND REMOVE ANY LOOSE MATERIAL
\pxql;4" AGGREGATE BASE
\pxql;6" CONCRETE SIDEWALK
\A1;2% MAX
\pxql;WWF 4" GRID \A1;3"\pxql;3" ASPHALT TREATED BASE (ATB)
\pxql;2" HOT MIX ASPHALT (HMA)
COMPACTED SUBGRADEOR BASE
NOTE: PAVING MATERIALS SHALL CONFORM TO WSDOT SPECIFICATIONS FOR 1/2-INCH CLASS HMA AND CRB.
\pxql;6' PARKING BUMPER (CENTERED IN PARKING SPACE)
\A1;2'\A1;BLUE WHEEL STOPS IN ADA PARKING STALLS
NOT TO SCALE
EXTRUDED CURB RADIUS
\pxql;4" DEPTH CONCRETE FINISH SAME AS SIDEWALK
CONCRETE REINFORCED\A1;3'\A1;3'\A1;R2.5'\pxql;EXTRUDED CURB
\A1;1":1'\A1;1":1'\pxql;PAVEMENT \pxql;PAVEMENT
\pxql;CONCRETE COMPACTEDSUBGRADE
\A1;18"\A1;18"
NOT TO SCALECONCRETE VALLEY GUTTER\A1;7"\pxql;3.5"
\pxql;WWF 4" GRID
\A1;1":1'\pxql;PAVEMENT \pxql;PAVEMENT
\pxql;CONCRETE COMPACTEDSUBGRADE
\A1;18"\A1;18"
NOT TO SCALE
ZERO HEIGHT CONCRETE CURB
\A1;7"\pxql;3.5"\pxql;WWF 4" GRID \A1;16"AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396222
NOTES AND DETAILS
AS NOTED
DT-04
2311AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396222
NOTES AND DETAILS
AS NOTED
DT-05
2312AS-BUILT DRAWINGS