Loading...
HomeMy WebLinkAboutzR-3962SetN PROJECT INFORMATION SITE ADDRESS: 17033 108TH AVE SE, RENTON, WA 98055 � TAX PARCELS: 0087000285, 0087000293 O GROSS SITE AREA: 65,715 SF (1.51 AC) ,,:I- ROW DEDICATION AREA: 4,565 SF (0.10 AC) 0 NET SITE AREA 61,150 SF (1.40 AC) w EXISTING USE: SINGLE-FAMILY RESIDENTIAL PROPOSED USE: CONVALESCENT CENTER - CONDITIONAL USE Uj CURRENT ZONING: R-14 CURRENT COMP PLAN: R-14 WATER: SOOS CREEK WATER & SEWER DISTRICT SEWER: SOOS CREEK WATER & SEWER DISTRICT POWER: PSE GAS: PSE TELEPHONE: CENTURYLINK CABLE: COMCAST SCHOOL DISTRICT: RENTON #403 w FIRE DISTRICT: RENTON RFA Ir SEISMIC DESIGN CATEGORY: D IBC DESIGNATION OF OCCUPANCY: 4-1 U STRUCTURAL DESIGN CRITERIA: LOAD OF 30 TON VEHICLE, 75 PSI, AND J 26%26" OUTRIGGER PER RENTON RFA Q MAXIMUM BUILDING HEIGHT: 35' SETBACKS: FRONT: 15, 0 REAR: 10, L1J SIDE: 4' SIDE (ALONG STREET): 15, U) OPEN SPACE REQUIREMENTS z MINIMUM OPEN SPACE REQUIRED: 0 SF IF THREE OR FEWER DWELLING UNITS 350 SF PER UNIT IF 4 OR MORE DWELLING UNITS 0 IMPERVIOUS REQUIREMENTS 1­_ MAXIMUM IMPERVIOUS: 80% z MAXIMUM LOT COVERAGE: 65% �J,J NEW IMPERVIOUS: 43,072 SF (70.40%) � NEW PERVIOUS: 18,078 SF LOT COVERAGE: 17,306 SF (28.30%) r REFUSE AND RECYCLING AREA REQUIRED RECYCLE: 51 SF REQUIRED GARBAGE: 102 SF PROVIDED: 180 SF PARKING REQUIRED: REQUIRED= 34 STALLS 25% REDUCTION= 26 STALLS COMPACT STALLS ALLOWABLE: 8 STALLS ADA STALLS REQUIRED: 2 STALLS PARKING PROVIDED: 26 STALLS COMPACT STALLS PROVIDED: 7 STALLS ADA STALLS PROVIDED: 2 STALLS 3 _J n I Cn I Q ro m I Q c 0 0 T 'E E E 0 0 0 U Q 0 o, co i m 0 N i C .3 0 0 EXISTING SYMBOLS ABBREVIATIONS SYMBOL DESCRIPTION CB CATCH BASIN O FOUND CASED MONUMENT, AS NOTED CENTERLINE FOUND REBAR &CAP, AS NOTED CMP CORRUGATED METAL PIPE o SET REBAR AND CAP CID CONCRETE PIPE STORM DRAIN MANHOLE EL ELEVATION ❑ STORM DRAIN CATCH BASIN O SANITARY SEWER MANHOLE EXIST. EXISTING NATURAL GAS VALVE It FLOWLINE FIRE HYDRANT IE INVERT ELEVATION WATER VALVE LCPE LINED CORRUGATED POLYETHYLENE PIPE ® WATER METER It PROPERTY LINE 0 BOLLARD PP POWER POLE POWER POLE W/LIGHT PVC POLYVINYL CHLORIDE PIPE -0- POWER POLE R/W RIGHT-OF-WAY O TELEPHONE MANHOLE STA STATION MAPLE TREE SD STORM DRAIN CEDAR TREE SS SANITARY SEWER PROPOSED STORM SYMBOLS SSMH SANITARY SEWER MANHOLE SYMBOL DESCRIPTION SWPE SOLID WALL POLYETHYLENE PIPE C SD CAP TYP TYPICAL El TYPE 1 CATCH BASIN, GRATED LID TBR TO BE REMOVED ❑� TYPE 1 CATCH BASIN, SOLID LID PROPOSED WATER SYMBOLS 0 TYPE 2 CATCH BASIN, GRATED LID SYMBOL DESCRIPTION ® TYPE 2 CATCH BASIN, SOLID LID ��DCONCRETE BLOCKING ❑ SQUARE YARD DRAIN 17 11' BEND 0 ROUND YARD DRAIN 45' BEND O STORM CLEAN OUT 90' BEND STORM PIPE 22' BEND PROPOSED SEWER SYMBOLS " VALVE SYMBOL DESCRIPTION HYDRANT ASSEMBLY C SEWER CAP ~ BLOW -OFF VALVE O SEWER CLEANOUT REDUCER SEWER MANHOLE AIR -VAC ASSEMBLY SEWER PIPE WATER METER WATER PIPE Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON HEARING EXAMINER'S REQUIREMENTS 1. A LOT COMBINATION SHALL BE RECORDED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, COMBINING THE TWO PARCELS INTO ONE. RENTON SPECIAL 2. A DETAILED LANDSCAPE PLAN MEETING THE REQUIREMENTS OF RMC 4-8-120D.12 SHALL BE SUBMITTED AT THE TIME OF BUILDING PERMIT REVIEW. THE DETAILED LANDSCAPE PLAN SHALL INCLUDE BUT IS NOT LIMITED TO THE FOLLOWING: A. A MIX OF TREES, SHRUBS, AND GROUND COVER CARE COMMUNITY WITHIN THE 10-FOOT LANDSCAPE STRIP ABUTTING SCALE: 1" = 40' THE SE 172ND STREET AND 108TH AVENUE SE STREET FRONTAGES; /� D� �/� 40' 0 40' 80' B. THE PROPOSED 10-FOOT FULL SIGHT -OBSCURING LANDSCAPE VISUAL BARRIER ALONG THE WEST GS PROPERTY LINE SHALL BE REQUIRED TO EXTEND ALONG THE NORTH PROPERTY LINE; AND RECORD DRAWINGS SHALL BE PREPARED, STAMPED, AND SIGNED BY A PROFESSIONAL ENGINEER OR IN THE STATE C. VERIFICATION THAT THE INTERIOR PARKING LOT OF WASHINGTON. ALL PLANS SHOWING AS -BUILT INFORMATION IN THE RECORD DRAWINGS AND THE COVEgsWtt%-5r",$MiYR6M�00ocumAWIN59 SHALL INCLI LANDSCAPED AREAS INCLUDE 1 SHRUB PER 20 A STAMP THAT INDICATES THAT THE PLAN SHEET CONTAINS AS -BUILT INFORMATION. THE STAMP SHALL BE M �yI�E�V T�UCTI& RECORD DRAWING". THE SQUARE FEET OF PROVIDED INTERIOR PARKING LOT �81.'ISFIE 'C STAMP SHALL INDICATE HOW THE AS -BUILT INFORMATION WAS OBTAINED AND THAT THE PROFESSIONAL ST*Mi'g'§8IE PLAN SHEET TAKES OWNERSHIP FOR THE LANDSCAPING, OF WHICH 50 PERCENT OF THE CONTENTS OF THE PLAN SHEET. SOMETHING LIKE THE FOLLOWING: E=1JO5835.75 SHRUBS MAY BE DECIDUOUS. - THE DETAILED LANDSCAPE PLAN SHALL BE SUBMITTED TO THE FOUND CO-00RDS• CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND �i APPROVAL. THE LANDSCAPING SHALL BE INSTALLED PRIOR TOCONSTRUCTIONDRAWING THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 3. THE APPLICANT SHALL EITHER REDUCE THE HEIGHT OF THE This c€ nstniction re -cord ch-a i k a c� ref a card file pre i b FOUND CASED FENCE TO COMPLY WITH THE 72-INCH HEIGHT REQUIREMENT P MONUMENT OR SUBMIT AN APPLICATION FOR, AND RECEIVE APPROVAL OF, and has } ,ri efted to reflect field W/LEAD TACK A SPECIAL FENCE PERMIT IN COMPLIANCE WITH THE STANDARDS OUTLINED IN RMC 4-4-040G. THE APPLICANT verified invert atw] t`im elovat io�ris of the stonn, satiatary sewer and vmtet, SHALL SUBMIT A REVISED FENCE DETAIL OR AN APPROVED SPECIAL FENCE PERMIT TO THE CURRENT PLANNING PROJECT mWn systems. Field vedrwd iriver(aixl iim elevations were obUned by MANAGER PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. IN 4. THE DESIGN OF THE BUILDINGS SHALL BE REQUIRED TO ` COMPLY WITH THE RESIDENTIAL DESIGN PORTION OF THE The on -site prhrdte storm drabdrab-Ege facifidesaW public/private water mxl .................. RESIDENTIAL DESIGN AND OPEN SPACES STANDARDS SET REBAR AND CAP APPLICABLE IN THE R-14 ZONE (RMC 4-2-115E.3) AND FOUND REBAR AND CA wer� "ems were rr 5Uled In accordance itE1 the aVpr' ved p is mid EMW 144651 ENHANCED LANDSCAPING BE PROVIDED WHERE COMPLIANCE LIES 0.32 N17W OF WITH THE ARCHITECTURAL DESIGN CANNOT BE ACHIEVED. CORNER the doC mmit field rev ins ajyl imcdon as intended. l 5. A LIGHTING PLAN SHALL BE PROVIDED AT THE TIME OF BUILDING PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. ,� DRIVEA 6. THE LOCATION OF THE REQUIRED BICYCLE PARKING SHALL BE ram -X F,\_F r I r���� ���r� r I roe PROVIDED ON THE SITE PLAN AND A DETAIL OF THE BICYCLE _i5' - 5 o ^ r J J J D J J 2-E S o PARKING SHALL BE PROVIDED. THE REVISED SITE PLAN AND frJ J J �J J J �, BICYCLE PARKING DETAIL SHALL BE PROVIDED AT THE TIME FOUND 1. 5" PIPE 0.85' N11'W OF BUILDING PERMIT REVIEW TO THE CURRENT PLANNING OF PROPERTY CORNER PROJECT MANAGER FOR REVIEW AND APPROVAL. 7. A SIDEWALK CONNECTION SHALL BE PROVIDED TO SE 172ND ----- --- STREET ALONG THE WESTERN PORTION OF THE PROJECT SITE. _ 8. ALL PROPOSED LOADING AREAS SHALL BE SEPARATED FROM SET REBAR AND CAP PARKING AND PEDESTRIAN AREAS AND SHALL BE LOCATED, EMW LS144651 DESIGNED AND SCREENED TO MINIMIZE VIEWS FROM COTTAGEB SURROUNDING PROPERTIES. -::.CnTTAnFA i. rrJJJ rJJJ �� J CITY OF RENTON MONJ/1862 (C, HORZ ONLY) COPPER PLUG WITH PUNCH ON A 4'X4 CONCRETE POST IN CASE, DOWN 0.45'. PUBLISHED CO-ORDS: N=168056.01 E=1300198.93 FOUND CO-ORDS: N=168056.34 L4 i E=1300199.16 W Q Z 0 L........ i 58: F8 R2) ................� ...................... N FOUND CASED MONUMENT W/TACK SEPA MITIGATION CONDITIONS PER LUA 17-000023 ECF, CUP MITIGATION MEASURES ARE NONE RECOMMENDED NPDES PERMIT NUMBER WAR 305778 1 thANN11MDCAQv Surveying 5 LDC Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com SET REBAR AND CAP EMW LS144651 TABLE OF CONTENTS 1 COVER SHEET 2 EXISTING CONDITIONS MAP 3 HORIZONTAL CONTROL PLAN 4 SITE PLAN 5 TESC PLAN 6-7 TESC NOTES AND DETAILS 8 GRADING PLAN 9 DETAILED GRADING PLAN 10 ROAD AND STORM DRAINAGE PLAN 11-15 ROAD AND STORM DRAINAGE PROFILES 0 1 AS -BUILT DRAWINGS NO. REVISION COPPER PLUG IN A J" CONCRETE FILLED PIPE IN A WSDOT CASE. DOWN 0.30'. PUBLISHED CO-ORDS: ELEV=380.86 FOUND CO-OORDS: ELEV=380.70 16 ROAD SECTIONS 17 STORM DRAINAGE DETENTION PLAN 18 COMPOSITE UTILITY PLAN 19 23 NOTES AND DETAILS WA-01- WA-05 WATER PLANS SS-0 I - SS-06 SEWER PLANS L000 TREE /NVENTORYAND RETENTION PLAN L 100-001 LANDSCAPE PLANS ES 01- ES-03 LIGHTING PLANS LANDSCAPE NOTES 1. LANDSCAPE PLAN WILL BE REVISE TO MATCH STREET LIGHT LOCATIONS ON THE CIVIL PLANS AND TREE LOCATIONS WILL BE ADJUSTED ACCORDINGLY. MEV 112-13-18 BY I DATE I APPR FOUND CASED MONUMENT TOPOGRAPHIC DISCLAIMER CONTACT LIST 0 o- w J Cn w 19120 zu 1 tea..—..— — 30 29 0 29 \ LL � w co o fQ o co N o _ G' z 21 4 28 1 w 1 J� 716m a Ip SE 172ND ST 30 29 SE 176TH ST 29 28 0 32 1� 32 33 \ I SE GP LJ L1: S 43RD ST i GO Q Q Do Do �: o f VICINITY MAP SCALE: 1"=2000' SURVEY INFORMATION LEGAL DESCRIPTION LOT 14, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. TOGETHER WITH: THE SOUTH HALF OF LOT 15, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. VERTICAL DATUM - NAVD-88 NORTH AMERICAN VERTICAL DATUM-1983 BENCHMARK 1 9 6 PROJECT BENCHMARK: FOUND REBAR AND CAP EMW LS144651(AS SHOWN ON MAP) ELEVATION = 409.72 FEET PROJECT BENCHMARK: CITY OF RENTON MON11640 3" BRASS DISC STAMPED "KING COUNTY SURVEY MONUMENT" IN CASE FOUND CO-ORDS: N=170649.17 E= I J05835. 94 ELEVATION = 465.87 FEET BASIS OF BEARING THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N 01 °4332" E EQUIPMENT & PROCEDURES METHOD OF SURVEY - SURVEY PERFORMED BY FIELD TRAVERSE INSTRUMENTATION.• OWNER/APPLICANT RENTON SPECIAL CARE COMMUNITY, LLC 2731 77TH AVE SE, SUITE 20J MERCER ISLAND, WASHINGTON 98040 CONTACT- KEVIN CARL PHONE: (206) 778-4725 kevin@MGgnet-dd.com Cl HL ENGINEER.• LDC, INC. 20210 142ND AVE NE WOODINVILLE, WASHINGTON 98072 CONTACT MARK VILLWOCK, PE PHONE- (425) 806-1869 FAX: (425) 482-2893 EMAIL: mvillock@ldccorp.com LANDSCAPE ARCHITECT ELM ENVIROMENTS 1925 POST ALLEY, SUITE 3B SEATTLE, WASHINGTON 98101 CONTACT- GREG MURPHY PHONE: (206) 393-8263 EMAIL: gmurphy@elmenv.com TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. SURVEYOR.• LDC, INC. 20210 142ND AVE NE WOODINVILLE, WASHINGTON 98072 CONTACT- MICHAEL MERRITT, PLS, CFedS PHONE: (425) 806-1869 FAX: (425) 482-2893 EMAIL: michaelm@ldccorp.com ARCHITECT JENSEN FEY ARCHITECTURE AND PLANNING P.S. 77JO LEARY WAY REDMOND, WASHINGTON 98052 CONTACT- REUBEN RIOS PHONE.- (425) 216-OJ18 EMAIL: Trios@jensenfey.com GEOTECH.• PROFESSIONAL SERVICE INDUSTRIES, INC. (PSI) 20508 56TH AVENUE WEST SUITE A L YNNWOOD, WASHINGTON 98036 GEOTECH CONTACT: MICHAEL S. PLACE, PE A S-B UIL T PHONE.- (425) 409-2504 FAX: (425) 582-8193 EMAIL: michael.place@psiusa.com CESCL: INTERTEK-PSI 20503 56TH AVE W, SUITE A L YNWOOD, WA 9804J CONTACT- MICHAEL a PLACE, PE PHONE: (425) 409-2505 EMAIL: michoe%place@psiusG.com DRA WINGS N COMPLIANCE WITH CITY OF RENTON STANDARDS SURVEYED: LDC SCALE: 1 �� _ Z O, JJ VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 83/1 C T Y 0F RENTON SPEC/AL CARE COMMUNITY, LLC uai L: 0 4- 0 8 -17 DESIGNED: MEV RENTON SPECIAL CARE COMMUNITY FIELDBOOK: RENTON PAGE: DRAWN: NC . 17033 108TH AVE SE, RENTON, WA 98055 DRAWING NO: C S - 01 ONE INCH DATUM Plan nin g/Buidin g/Public Works Dept. (/� COVER SHEET CHECKED: MEV AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY APPROVED:MEV SHEET: 1OF: 23 00 N C) T N O O T Q J N co co i i 0 w LU rr Q U Q U LU U)Z z O z w rr 0 0 0 0 n 3 J m I 0 F- I Q m 0 U) m I m Q 3 0 0 T E E 0 0 0 0 CJ 0 0 (D o_ V) C 0 re m co 0 N i CL 6) .3 0 0 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON Y iiLii i /I CITY OF RENTON MON 1640 (D, HORZ & ELEV r BRASS DISC STAM ED "KING COUNTY SURVEY MONUMENT', IN CASE, DOWN 1.0. PUBLISHED CO-ORDS N=170646.98 E=1305835.75 ELEV=466.09 FOUND CO-OORDS• N=170649.17 E=1305835.94 ELEV=465.87 a SCALE: 1" a e e ••:: i _ :5 a SHED LIES . SET REBAR AND CAP ° �. 0 .I. 2:5' S: OF l EMW j44651 \ ... . U- 20' 0 20' 40' FOUND CASED MONUMENT W/LEAD TACK \ r r r J r RCEL i i r PRO11 PERTY LINE / \ ... FOUND REBAR AND CAP ' _ — — =F�J J �J J J PJ 1 CRONES — — o . N88' 13 13 W LIES 0.32' N17'W � � � � � 299.81'(C)........................................:.....:.:......:...:..�......... �\ ......I.........:c" a OF PROPERTY CORNER I / 24 .......................... / p� SURVEY INFORMATION x I I _ _ _ _OLD — I 12" 12" ° . \..........�. Z ....... a 0 LEGAL DESCRIPTION a a ti ........ I I x e e CONCRETE / 24 10 M I a LOT 14, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECOI I I DIRT FILLED POOL ° / / 6" I IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. x I rr\\X Pr\RC r d a e d a a / BUILDING %/ 10>> o =rrJ J J 0 J J 20 CHAIN LINK a ... / 17033 coMc TOGETHER WITH: I /: 108TH AVE d 8„ o °\ w I FENCE LIES e / e CONCRETE THE SOUTH HALF OF LOT BLOCK KER'S F I \ w I 0.4' N. of e ° °° d / WALK o I 15, B K 4, A ARM N0. 5, ACCORDING TO THE 0 0 \ PROPERTY LINE e d e 1. PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING e 0„ 18 .. COUNTY, WASHINGTON. m I e . e . — r I T / x I `CONCREr ° I 18" .. ' SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. �rJ J J 70 J J» J I e ROOF PEAK � I I ° c' FOUND 1.5" PIPE III I i EL=428.00' 16" 2 „ ` '. '.c� a.... \ �j\� e VERTICAL DATUM — NAVD-88 L I `� NORTH AMERICAN VERTICAL DATUM-1988 0.85 N11 W 12 W. OF PROPERTY CORNER G .....:.. . H K RAVEL .DRIVEWAY ... CURB .FACE . K aENc I 32" I BENCHMAR \ ......... d . ........ ........ . ........ ......... .. PROJECT BENCHMARK.• \ — — SET .At, aaR .AnID eaP .. . ... ...................... ...... . . • • EMW LS44651 a I FOUND REBAR AND CAP EMW LS144651(AS SHOWN ON MAP) SET REBAR AND CAP ELEVATION = 409.72 FEET EMW LS#44651 _ — — -� \ 10 \ — — ca L .. W ........... d a PROJECT BENCHMARK.• >r FENCE LIES 12" 0.4' W. of :::',� �'' I \ „ 0 W I CITY OF RENTON MON11640 PROPERTY LINE �•: — —\ 1 \\ \ 20 S' BRASS DISC STAMPED "KING COUNTY SURVEY MONUMENT" IN CASE \ \ \ \ \ 20" \ I. ............... ..... ..... : \ o \ L \ Or)` 10" \ WOOD \\ .....20m:NO170649.10RDS: I \ \ ENCLOSURE „ \ V I r E=IJ05835.94 \ \ \ 12 46 26" Q ::: 14" `- I ELEVATION = 465.87 FEET \ \ \ \ „ i e BASIS OF BEARING \ \ \ \ \CS r-\�; Pr\RCr \ \ \ \ \ \ \ \ a THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N O1'43' \ ............... ...... . ..... \ \ 10 \ \ \ \ 3 EQUIPMENT & PROCEDURES 4/0\0 20» ........ �� I METHOD OF SURREY \ N ......... SURVEY PERFORMED BY FIELD TRAVERSE ...... . ........ I FENCE LIES Z \ / _ _ — — / : •,; \ , ` \ �N o c�' a I INSTRUMENTATION.' PROPERTY LINE \AC r••.: °\ :'...' ` N. I.... e I LEGEND \ \ CENTER OF MANHOLE \ o ..�........ d \... �' ........ FH e \ \ \ LIES 3.3' E. ................... . \ \ \ 24I o I CONCRETE BLOCK WALL � I \ \ \ � ' OF PROPERTY LINE � ............. LIES 1.6' \ \ \ \ \ I �.......... . ° I • E. OF PROPERTY LINE \ \ �Q — — _ \ 18" S S....... �............. d. 6_ — S S TAX PARCri „ \ I I Q-, 40J� 10DD :3 5 \\ 14 SSMH RIM=411. 14 IE=401.53(N,j PVC) \...... I ............... / I El FENCE LIES \ \ \ A\ \ \ \ \\ 8' 8" II SSMH e / 1 O / \ _ 3.1' E. OF \ — �I \ / i \ EM398.48 (N,S,E,W) PROPERTY LINE \ — _ � � \ I <\ � ... IE=404.71'(N 8") a � 12 I 32" \ 14" LL... CONCRETE PILLAR \ \ \ \ \ I 0 \ \ I o I ......... ..... 0 LIES 0.4' W. OF \ \ \ \ \ \ \ I L \ / o r o....... / PROPERTY LINE \ \ \ 12 \ I \ \ 28" / 12" \ ��\ \ I 24' \ 7 \�/\� ........... ° d / o POWER POLE \ — — — . \ 12 CEDAR \ \ \ / \ \ Il . _ J. 12"� L.�.\..... .�.. LIES 4.2' E. AND A00� \ \ \ I \ 30" e CONCRETE BLOCK WALL 5.2' N. OF LIES 4.2' E. PROPERTY LINE \ \ \ \ \ MULTI1:... .c.B . `� CITY OF RENTON MON11862 (C, HORZ ONLY) OF PROPERTY LINE \ \ " \ COPPER PLUG WITH PUNCH ONA4X4 ��� CENTER LINE—` `1L IL------- ----32 \ZE�R — 0 e ed 0 —� OF DITCH �\ —----- —__ w--- W.—.. f.-.W CONCRETE POST IN CASE, DOWN 0.45'. CULVERT---, \ — — — — — _ — — — Pi�RiicuFn �n-Wane• I�-�oF �d� � r- — — FOUND CASED MONUMENT, AS NOTED FOUND REBAR & CAP, AS NOTED SET REBAR AND CAP STORM DRAIN MANHOLE STORM DRAIN CATCH BASIN SANITARY SEWER MANHOLE NATURAL GAS VALVE FIRE HYDRANT WATER VALVE WATER METER BOLLARD POWER POLE W/LIGHT POWER POLE TELEPHONE MANHOLE MAPLE TREE CEDAR TREE AS-BUILT DRAWINGS TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. . ........................ .... _ _ _ ......:. .... _ / _ ........................... EMW LS144651 � IN COMPLIANCE WITH CITY OF RENTON STANDARDS \ I� I IE=391.23'(E,6' PVC) IE=403.52'(12"GONG) I......... BACK OF SIDEWALK G.. ......... �. svL.. 30467=...... IE=391.13'(W g„PVC) \ �'................'.'.'.. G G \ G I \. ................................. �...... ... CULVERT G G G..........................:N...... RIM.=39.5:85................ G 399.22' 12 CMP� \ PPP ........................................ SIG I — G ..... . . IR 392�5 (E;12"CMH FH X_T X X ,�, FOUND CASED MONUMENT ......:2....1......... ... _ _ — — FDC WATER GARBAGE.'COI�IIAINFR ........................... . ............................... W/TACK VAULT Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 1 thANNIXir- QcADV Surveying Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. REVISION A \ Pr\R r -rr%J % 30 _6J -17 E3 MEV 112-13-18 I ' SURVEYED: LDC DESIGNED: MEV DRAWN: NC ' CHECKED: MEV BY I DATE I AP P R I APPROVED: MEV CITY OF RENTON MON/�1915 (8, ELEV ONLY) COPPER PLUG IN A 3' CONCRETE FILLED PIPE IN A WSDOT CASE. DOWN 0.30'. PUBLISHED CO-ORDS: ELEV=380.86 FOUND CO-OORDS: ELEV=380.70 ■ SCALE: ■ 1" =20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VER11ClL: HAVD 1988 HOMONTAL• W 1901IN1 DATU M ORC TY OF RENTON Planning/Building/Public Works Dept. RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 EXISTING CONDITIONS MAP R-396202 000 .— O 8 — 1 7 FIELD PAGE: DRAWING NO: TO-01 2 23 00 N O T NJ co O O T Q J H H • L4-W C'7 i 0 w Uj rr Q U J Q U w n U) z O z W rr SCALE: 1" = 20' 20' 0 20' 40' AS-BOIL T DRAWINGS NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWIN 23, RGE 5 E, KING COUNTY, WASHINGTON I I I =r00E� 7000 29- -1 INTERSECTION, ROAD STA 5+ 19.12, DRIVE A= N=166929.86 STA 12+13.23, 108TH AVE SE E=1302734.43 FOUND REBAR AND CAP 4 = 90'01 ' 14" SET REBAR44AND CAP CRONES R = 35 LIES 0.32' N17W L = 54.99 N=166920.54 OF PROPERTY CORNER T = 35.01 10' LANDSCAPE E-1303034.10 BUFFER N88'13'13"W 299.81 '(C) �-I ------ -�_- _--- w--_____Q5__-__ _ zW R45' / Cq _ _ -�c, N 4+00 _ _ 178_34 o I 85 3+00 I_ 4 _ _ _ - - o w w m 358°13'1C4 mu 3»- A w rrDD DDw2r;,---_-- - - - - FOUND 1.5"PIPE I /i---------�� 5'.\ o \\ -- 0.85' N11'W I I R�2' m OF PROPERTY CORNER / N=166859.58 I / `\ �y 39' \ L \ E=1302732.27 I I I FU, �F \ 71 ' 77-777 SET REBAR AND CAP I I \ \ i EMW LS144651 I I �WATWRiESMT 15'x12' POWER ESMT I� .. I I II �- -� - --I 15.3' I I COTTAGEA COTTAGE B 1 57 I CITY OF RENTON MON11640 (D, HORZ & ELEV) 3" BRASS DISC STAMPED "KING COUNTY SURVEY MONUMENT", IN CASE, DOWN 1.0: PUBLISHED CO-ORDS: F N=170648.98 E=1305835.75 ELEV=466.09 FOUND CO-OORDS: N=170649.17 E=1305835.94 ELEV=465.87 FOUND CASED MONUMENT W/LEAD TACK rn I I I UTILITY ESMT I ...:.... 110' . .... 18, . .: ...... .. LANDSCAPE BUFFER oS WATER & ^� I I IIIIIII IIb EMERGENCY I ±2o01' I CITY ITY/ SEWER -r�\\< ��\r�rr E/1I / �I II II I , IACCESS ESMT .8� Lr)I I 100.2' I� 04 101.3101.3' r 20.5' 15.5' R W DEDICATION57 45' CO TTAGE D N COTTAGE C 10, TOPOGRAPHIC DISCLAIMER SD N CO TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS L_ ESMT BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE III I I ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND 16' BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE 10' LANDSCAPE I WATER & 10' LANDSCAPE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE BUFFER I I I SEWER ESMA BUFFER ENGINEER. 110' 'LS6. :s I-----02 SD N=166701.26 I�SMT I E=1302727.41 CITY OF RENTON MON11862 (C, HORZ ONLY) , N88°07'55"W 300.54'(C) 300.62'(P) COPPER PLUG WITH PUNCH ON A 4"X4 4.5' R/W DEDICATION 3'X6' WATER ESMT CONCRETE POST, IN CASE, DOWN 0.45: Q PUBLISHED CO-ORDS T SET REBAR AND N=168056.01 EMW LS144651 E=1300198.93 FOUND CO-ORDS: 0 N=168056.34 E=1300199.16 661.23'(R2) - 13+00 58 68'(R2) 661.35'(P) rvUND CASED MONUMENT W/TACK Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center w 0 I 0 17+00 -- -+ + - 0 719. 91 '(M) 719. 94'(R3i - N88°07'55"E INTERSECTION, ROAD Z STA 0+00.00, DRIVE A= STA 16+89.94, SE 172ND ST 1 thANNIVERc"[)X Surveying L I DC Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 0 1 AS -BUILT DRAWINGS www.LDCcorp.com I NO. REVISION �rno SE 172ND ST 19+ 0 - 2 ;- �, (El' MEV 12-13-18 SURVEYED: LDC DESIGNED: MEV DRAWN: NC CHECKED: MEV BY DATE APPR [APPROVED: MEV SCALE: 3'X6' WATER EASEMENT (REC. NO. 80081 J0467) (TO BE RELINQUISHED) I I 30, EX R W I I SURVEY INFORMATION LEGAL DESCRIPTION LOT 14, BLOCK 4, AKER'S FARM NO, 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. TOGETHER WITH: THE SOUTH HALF OF LOT 15, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON, SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. VERTICAL DATUM - NAVD-88 NORTH AMERICAN VERTICAL DATUM-1988 BENCHMARK BENCHMARK PROJECT BENCHMARK. FOUND REBAR AND CAP EMW LS1144651(AS SHOWN ON MAP) ELEVATION = 409.72 FEET PROJECT BENCHMARK. CITY OF RENTON M0NJ1640 3" BRASS DISC STAMPED "KING COUNTY SURVEY MONUMENT" IN CASE FOUND CO-ORDS: N=170649.17 E= I J05835. 94 ELEVATION = 465.87 FEET BASIS OF BEARING 5+00 THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N O1°4332" E EQUIPMENT & PROCEDURES of 0 +T N 1=166850.23 E=1303031.98 I SET REBAR AND CA EMW LS144651 I I E=1303027.78 30, SET REBAR AND CAP J hh' EMW LS#44651 1�1_4 INTERSECTION, ROAD 11 STA 10+00.00, 108TH AVE SE= STA 20+00.00, SE 172ND ST CITY OF RENTON MON11915 (8, ELEV ONLY) COPPER PLUG IN A 3 CONCRETE FILLED PIPE IN A WSDOT CASE. DOWN 0.30'. PUBLISHED CO-ORDS: ELEV=380.86 FOUND CO-OORDS ELEV=380.70 1"=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY C6 W IQ O I� HORIZONTALN D ;N3,1"I CITY OF 1;R] RENTON NAROF DATU M Planning/Building/Public Works Dept. METHOD OF SURVEY - SURVEY PERFORMED BY FIELD TRAVERSE INSTRUMENTATION.• LEICA TCRA 1105 ROBOTIC ELECTRONIC TOTAL STATION PRECISION. MEETS OR EXCEEDS STATE STANDARDS WAC 332- I30-090 BASIS OF BEARING. - THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N 01 °43'32" E. PROJECT INFORMATION SITE ADDRESS: 17033 108TH AVE SE, RENTON, WA 98055 TAX PARCELS: 0087000285, 0087000293 GROSS SITE AREA: 65,715 SF (1.51 AC) ROW DEDICATION AREA: 4,565 SF (0.10 AC) NET SITE AREA 61,150 SF (1.40 AC) EXISTING USE: SINGLE-FAMILY RESIDENTIAL PROPOSED USE: CONVALESCENT CENTER - CONDITIONAL USE CURRENT ZONING: R-14 CURRENT COMP PLAN: R-14 WATER: SOOS CREEK WATER & SEWER DISTRICT SEWER: SOOS CREEK WATER & SEWER DISTRICT POWER: PSE GAS: PSE TELEPHONE: CENTURYLINK CABLE: COMCAST SCHOOL DISTRICT: RENTON #403 FIRE DISTRICT: RENTON RFA SEISMIC DESIGN CATEGORY: D IBC DESIGNATION OF OCCUPANCY: 4-1 STRUCTURAL DESIGN CRITERIA: LOAD OF 30 TON VEHICLE, 75 PSI, AND 26"x26" OUTRIGGER PER RENTON RFA MAXIMUM BUILDING HEIGHT: 35' SETBACKS: FRONT: 15' REAR: 10, SIDE: 4' SIDE (ALONG STREET): 15' OPEN SPACE REQUIREMENTS MINIMUM OPEN SPACE REQUIRED: 0 SF IF THREE OR FEWER DWELLING UNITS 350 SF PER UNIT IF 4 OR MORE DWELLING UNITS IMPERVIOUS REQUIREMENTS MAXIMUM IMPERVIOUS: 80% MAXIMUM LOT COVERAGE: 65% NEW IMPERVIOUS: 43,072 SF (70.40%) NEW PERVIOUS: 18,078 SF LOT COVERAGE: 17,306 SF (28.30%) REFUSE AND RECYCLING AREA REQUIRED RECYCLE: 51 SF REQUIRED GARBAGE: 102 SF PROVIDED: 180 SF PARKING REQUIRED: REQUIRED= 34 STALLS 25% REDUCTION= 26 STALLS COMPACT STALLS ALLOWABLE: 8 STALLS ADA STALLS REQUIRED: 2 STALLS PARKING PROVIDED: 26 STALLS COMPACT STALLS PROVIDED: 7 STALLS ADA STALLS PROVIDED: 2 STALLS FOUND CAS, IN COMPLIANCE WITH CITY OF RENTON STANDARDS MONUMENT RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108TH AVE SE, RENTON, WA 98055 HORIZONTAL CONTROL PLAN R-396203 04-08-17 REU IM; PAGE: DRAWING NO: HC-01 SHEET: OF: 323 C'7 00 N C) 0 T N 0 C) i T Q J F5 H H H NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N c9 co 0 w LEGEND SCALE: 1" = 20' 20' 0 20' 40' FOUND CASED MONUMENT W/LEAD TACK I ,. N=166929.86 `'": / ......... z E=1302734.43 % . COVERED REFUSE AND RECYCLING AREA EMT 446 A CAPS a o 6 CEDAR FENCE TO BE INSTALLED I :.. EMw #44B51N0 \ �...... o' rr��< P /\R r DIRECTLY ADJACENT TO PROPERTY LINE FOUND REBAR AND CAP i 10, 0 LANDSCAPE — _ ` _ _ N=166920.54 ., BUFFER F�JJ� IJJJ �:� J _ _ 1' -----.-..,. \ � ., \. ..... .........o. . W/IAUK I UIUI\L rr\VLIVILINI rNINU I\UrU YYVI\r\ —UKIVtWAT F'tK JIU IU4, .° BY "AVANA RIDGE" DEVELOPMENT SEE DT-04 AND GR-02 TOPOGRAPHIC DISCLAIMER A S-BUIL T TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS o BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DRA WINGS DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND , IBETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE CI E• VIL L \/ IG Q C A 1? Y FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE i O N i .3 0 0 of wasgll�p t A N N I ENGINEER. r?� Surveying SURVEYED: LDC SCALE. VERTICAL: NAVD 1988 ■ 0 AS —BUILT DRAWINGS MEV 12-13-18 Engineering DESIGNED: 1"- 20' HORIZONTAL: NAD 1983/1991 C T Y OF DC1Planning MEv OR RENTON 40908 g DRAWN: �GISTER���1�� NC ONE INCH DATUM Sj0 St,11 20210 142nd Avenue NE Ph. 425.806.1869 CHECKED: AT FULL SCALE NAL �, MEv Planning/Building/Public Works Dept. Woodinville, WA 98072 Fx. 425.482.2893 IF NOT ONE INCH www.LDCcorp.com NO. REVISION BY DATE APPR APPROVED: MFV SCALE ACCORDINGLY RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 SITE PLAN R-396204 co 00 C) T XJ co N O O O O T J I H H • H T n •.. M Cp LU cj �C U Q )4-08-17 IOOK: VG N0: R SP-01 Z 4 F: 23 N (0 O C'7 0 w w rr Q U J Q U w In z O z w rr H n U 0 rr\x Pr\JF�r r L =FPJJE') 1000 27-6 r-\�< P_/\PC r 40J2) 1000 �) 2) J 63LF12" SD®9.5% -o RETAINING WALL.--\ I . ... _J w ............. ...: .......... o.............. ............ LL, I r.........................�?.............. r� ......... �.".". ................. iI __ SD m — — ®ham \� --G-----G—---�G-----G c / E o - — 0 0 U AS-BOIL T Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 15 thANNI'Vir- QcADV Surveying LDC1 Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com V IfILL \11 IfI1I VLIIVf\ I I\V I LV I IV I LIV\JL (5' BEYOND DRIP LINE) 0 1 AS —BUILT DRAWINGS NO. REVISION f........................................ EARTHWORK QUANTITIES CUT: 7,466 CY (10,500 TONS) FILL 4,991 CY (7,000 TONS) NET: 2,2475 CY FILL/IMPORT (3,500 TONS) DISTURBED/CLEARING AREA: 87,170 SF (2.00 AC) *NOTE: NET EARTHWORK VOLUME ESTIMATE ASSUMES 50% OF EXCAVATED SOILS WILL BE UNSUITABLE FOR SITE BACKFILL USE. .:.., ...... .......... ...... ........... .... ..... a :":":":":"...":":":"......:":": .":":":" a a I :::::: :.:.:.:.:.:.:.".". .:.:.:. ...... .........�..... ................. "."." ".".".".".".". �_: ...... d ........"...... - ."."."." dl .. �............�....... ::.......".".".".".".".":::".".".". P I ......".".".".".".".".".".....".".". .1.....:":":":":":":":":"::::":":": Op............. 4:: i::":":":":":":":":":"::..... ..... d I "" ...... ......... """" """ . .... dd ...:.:.:. ...... .:.:.:.:.:.:....� ......... ..... ... .. aFH I a ........::::::::: s d. s I I I ...." ................ .................. ..... / r ��::�:::::::::::::: :":"� :::::::::: , d 0 .................. .... ........:�....... ............ .... d/ ...... ................. . . . . . . . . . . \.� ....... _ J 'd :::: ::::::::... a Cn ....".". .".".".".".".".".".".". .. . . t _w -. ..—.—.— ... ...... .... """" a _ ::;. .....4 a d .... .......... ...................... ...................... ....... ............ ......... ........ ... .......... C d. ...... ............ ®:":":":":":":"::.. a. . ..."."."."."."."."."."� ..� .......... .... ........ .."."."."."."."."....fz; ........"............._...w ...................:60..� ..�...".".".".".".".". .........U,............ ........................ .".".".".".". . ...................... ...."."."."."."."....".".".".".".".".".".". ............ "............. ........ 8„.b.I...:." .:.......................... ............... . ..i.y...". — G...... WA. MAIN ......".".".".".".".".".. . ............ ......".."."."."."."."."."."."."."."."."."." " . ........ """" """ S ..".".".".".".".".". . ........................z. ......... ."."."."."."."."."."."."."."."."."."."..."."."."."."."."....... .".".".".".".".".".".".".". . ............................� G _ � .... ......... .... ....... ........................o. .............................. / ..........................CN.............. p ........................... ............................ .......... ........ ............................. \ TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. SCALE: 1" = 20' 20' 0 20' 40' LEGEND CLEARING AREA PROTECTED AREA CLEARING LIMITS SILT FENCE, STD. PLAN 214.00, ER-02 ► •- CONVEYANCE SWALE 01 ROCK CONSTRUCTION ENTRANCE °°:°0. °�`� CATCH BASIN PROTECTION, STD PLAN 216.30, ER-03 TESC POND, STD PLAN 216.00, ER-02 PRE DEVELOPMENT DRAINAGE PATTERN POST DEVELOPMENT DRAINAGE PATTERN RIP RAP PAD INSTALL CHECK DAM EVERY 100' OR 2' OF ELEVATION CHANGE, STD. PLAN 217.40, ER-03 TBR TO BE REMOVED CONSTRUCTION SEQUENCE 1. PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE —CONSTRUCTION CONFERENCE WITH THE CITY OF RENTON STAFF. CESCL SHALL ATTEND CONFERENCE. 2. FLAG CLEARING LIMITS. 3. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR. 4. INSTALL CATCH BASIN PROTECTION ONSITE AND WITHIN 500' DOWNSTREAM OF SUBJECT PROPERTY. 5. GRADE AND INSTALL ROCK CONSTRUCTION ENTRANCE. 6. INSTALL FILTER FABRIC FENCE AND CONSTRUCTION FENCE AS SHOWN. 7. CONSTRUCT SEDIMENT TRAP AND OUTFALL. 8. GRADE AND STABILIZE CONSTRUCTION ROADS. 9. CONSTRUCT SURFACE WATER CONTROLS (CONVEYANCE SWALES, CHECK DAMS AND TEMPORARY CULVERTS) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 10. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. 11. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY ESC MINIMUM REQUIREMENTS. 12. COVER ALL AREAS WITHIN THE SPECIFIED TIME FRAME WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, CRUSHED ROCK OR EQUIVALENT. 13. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS. 14. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 15. CLEAN OUT STORM SYSTEM INCLUDING SEDIMENT TRAP AND STRUCTURES WHEN CONSTRUCTION IS COMPLETE AND SITE HAS STABILIZED. 16. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE. PROPOSED GROUND COVER COMBINATION OF TREES, LANDSCAPING AND IMPERVIOUS SURFACES ASSOCIATED WITH 16 BUILDINGS OR 360 UNITS. IMPERVIOUS AREAS (ON -SITE EXISTING ONSITE IMPERVIOUS: 6,238 SF (9.49%) NEW IMPERVIOUS: 43,072 SF (70.40%) NEW PERVIOUS: 18,078 SF (27.6%) LOT COVERAGE: 17,306 SF (28.30%) N COMPLIANCE WITH CITY OF RENTON STANDARDS MEV 12-13-18 SURVEYED: LDC SCALE: 1„— 2 O, L VERTICAL: NAVD 83/1 HORIZONTAL: NAD 1983/1991 DATUM C T Y OF � RENT0N Nkw g/ g/ p Buidin Public Works De t.BY RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 >08THAVE SE, RENTON, WA 98055ONE TCHECKED: / ESC PLAN R-396205 0 8 —17 DESIGNED: MEV DRAWN: NC INCH rFIELDBOOK: -01 MEVAT FULL SCALE IF NOT ONE INCHPannin ACCORDINGLY DATE APPR APPROVED: MEVSCALE OF: 23 CY) 00 (fl N O O T 561J C'7 N O O O O T Q J NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N c9 co I 6 I W W rr Q U U W In 0 Z 0 Z W rr K01 o, 3 0 W I Q r Lo i M I 00 0 00 O L 0 T E E O U N I_ 0 0 (D Q (n 0 n, r7 Lo 0 N i .3 0 0 IN 6"x6" MIN. TRENCH PILE AT 12" INTERVALS v , TURN THExEND UNDER 4' AND STAPLE AT 12" INTERVALS NOTES 1. CONDITION OF USE 1.1. FOR PERMANENT STABILIZATION OF SLOPES 2H:1V OR GREATER AND WITH MORE THAN 10 FEET OF VERTICAL RELIEF. 1.2. IN CONJUNCTION WITH SEED FOR FINAL STABILIZATION OF A SLOPE, NOT FOR TEMPORARY COVER. HOWEVER, THEY MAY BE USED FOR TEMPORARY APPLICATIONS AS LONG AS THE PRODUCT IS NOT DAMAGED BY REPEATED HANDLING. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. INSTALLATION IS CRITICAL TO THE EFFECTIVENESS IF THIS PRODUCT IF GOOF GROUND CONTACT IS NOT ACHIEVED, RUNOFF CAN CONCENTRATE UNDER THE PRODUCT, RESULTING IN SIGNIFICANT EROSION.. 2.2. JUTE MATTING MUST BE USED IN CONJUNCTION WITH MULCH. EXCELSIOR, WOVEN STRAW, BLANKETS, AND COIR ( COCONUT FIBER) BLANKETS MAY BE INSTALLED WITHOUT MULCH. 2.3. PURELY SYNTHETIC BLANKETS ARE ALLOWED, BUT SHALL ONLY BE USED FOR LONG-TERM STABILIZATION OF WATERWAYS. THE ORGANIC BLANKETS, ARE BETTER FOR SLOPE PROTECTION AND SHORT-TERM WATERWAY PROTECTION BECAUSE THEY RETAIN AND PROVIDE ORGANIC MATTER TO THE SOIL, SUBSTANTIALLY IMPROVING THE SPEED AND SUCCESS OF RE -VEGETATION. 3. MAINTENANCE STANDARDS 3.1. GOOD CONTACT WITH THE GROUND MOST BE MAINTAINED, AND THERE MOST NOT BE EROSION BENEATH THE BET OR BLANKET. 3.2. AREAS OF THE NET OR BLANKET THAT ARE DAMAGED OR NOT CLOSE CONTACT WITH THE GROUND SHALL BE REPAIRED AND STAPLED. 3.3. IF EROSION OCCURS DUE TO POORLY CONTROLLED DRAINAGE, THE PROBLEM SHALL BE FIXED AND THE ERODED AREA PROTECTED. F PUBLIC WORKS SLOPE INSTALLATIONS STD. PLAN - 215.20 DEPARTMENT MARCH 2O08 INFLOW THE POND LENGTH SHALL BE 3 TO 6 TIMES THE MAXIMUM POND WIDTH EMERGENCY OVERFLOW SPIL SILT FENCE ` RISEIf'PIPE % / / I CDISCHARGE ONVEYANCE, LEVEL YANCESPREA, OUTLET OR RISER PIPE (PRINCIPAL SPILLWAY) OPEN AT TOP WITH TRASH RACK \ DEWATERING DEVICE (SEE RISER DETAIL)��jr CREST OF 6' MIN. WIDTH EMERGENCY SPILLWAY I EMBANKMENT COMPACTED S6%. PERVIOUS MATERIALS SUCH AS GRAVEL OR CLEAN SAND SHALL NOT BE USED. - WIRE -BACKED SILT FENCE, DEWATERING III _ _ III "' "' STAKED HAYBALES WRAPPED ORIFICE -III I -III I I: WITH FILTER FABRIC, OR :III- -III-III-III DISCHARGE TO STABILIZED EQUIVALENT DIVIDER CONCRETE BASE CONVEYANCE, OUTLET OR LEVEL SPREADER NOTES 1. CONDITION OF USE 1.1. A SEDIMENT POND SHALL BE USED WHERE THE CONTRIBUTING DRAINAGE AREA IS 3 ACRES OR MORE. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE POND SHALL BE DIVIDED INTO TWO ROUGHLY EQUAL VOLUME CELLS BY A PERMEABLE DIVIDER THAT WILL REDUCE TURBULENCE WHILE ALLOWING MOVEMENT OF WATER BETWEEN CELLS. THE DIVIDER SHALL BE AT LEAST ONE HALF OF THE HEIGHT OF THE RISER. WIRE - BACKE 2-TO 3 FOOT HIGH, EXTRA STRENGTH FILTER FABRIC SUPPORTED BY TREATED 4"X4"s MAY BE USED AS A DIVIDER. ALTERNATIVELY, STAKED STRAW BALES WRAPPED WITH FILTER FABRIC MAY BE USED. 2.2. IF THE POND IS MORE THAN 6 FEET DEEP, A DIFFERENT MECHANISM MUST BE PROPOSED. 2.3. TO AID IN DETERMINING SEDIMENT DEPTH, ONE -FOOT INTERVALS SHALL BE PROMINENTLY MARKED ON THE RISER. 3. MAINTENANCE STANDARDS 3.1. SEDIMENT SHALL BE REMOVED FROM THE POND WHEN IT REACHES 1 FOOT IN DEPTH. 3.2. ANY DAMAGES TO THE POND EMBANKMENTS OR SLOPES SHALL BE REPLACED. �Y �� PUBLIC WORKS SEDIMENT POND PLAN VIEW STD. PLAN - 216.00 '' DEPARTMENT AND CROSS SECTIONS gN,tp MARCH 2O0B Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS_ 6' MAX L-J POST SPACING MAY BE INCREASED TO W IF WIRE BACKING IS USED 2N2" BY 14 Ga. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC MINIMUM 4"x4"TRENCH BACKFILL TRENCH WITH NATIVE SOIL 2'k4' WOOD POSTS, STEEL FENCE POSTS, REBAR, OR EQUIVALENT 2F NOTES 1. CONDITION OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. 3D-100 SIEVE SIZE (D.60-0.15MM( FORSI LT FILM A05 (ASTM D4751) 60-100 SIEVE SIZE (0.30-D.15MM) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D491) D.02SEC^-1 MINIMUM GRAB TENSILE STRENCHT (ASTM D4632) 1RD LBS. MIN. FOR EXTRA STRENGH FABRIC 1DD LBS. MIN. FOR STANDARD STRENGHT FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 3D % MAX. ULTRAVIOLATE RESISTANCE (ASTM D4355) 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2HAV 2.4. IF A TYPICAL SILT FENCE IS USED THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. 3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. 3.4. SEDMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. ti�Y STD. PLAN - 214.00 � �� � PUBLIC WORKS SILT FENCE '' DEPARTMENT gN tp MARCH 2O0B Polyethylene cap Provide adequate ping Perforated polyethylene drainage tubing, diametCorrugated min. 2" larger thanmetal riser dewatering orifice. ,Tubing t:Watertight MIN. shall comply3.5 with ASTM F667 andTack Dewateling orifice, chedule, AASHTO M294Diameteraspercalculations weld 40 steel stub min. I 6" min. r--- 18" min. Alternatively, metal stakes Concrete base and wire may be used to prevent flotation 2X riser dia. Min. Figure 4.2.20 - Sediment Pond Riser Detail 15 th A N N 1 T4'r- o C! A Ry Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. DRIVEWAYS SHALL BE PAVED TO THE EDGE OF R-O-W PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS 12" MIN. THICKNESS PROVIDE FULL WIDTH OF NOTES \II INGRESS/EGRESS AREA 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. GRAB TENSILE STREBNGTH (ASTM D4751) 200 PSI MIN. GRABTENSILE ELONGATION (ASTM D4532) 30'A MAX. MULLEN BURSTSTRENGTH (ASTM D3785-80A) 400 PSI MIN. AOS (ASTM D4751) 20-4S (U.S. STANDARD SIEVE SIZE) 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANYTIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. PUBLIC WORKS STABILIZED ti�Y � STD. PLAN - 215.10 � �� � DEPARTMENT CONSTRUCTION ENTRANCE MARCH 2O0B FN'f TESC SEDIMENTATION POND BOTTOM ELEVATION 393.00 BOTTOM AREA (SF) 16 SF TOP ELEVATION 397.00 TOP AREA (SF) 784 SF SIDE SLOPES 3:1 OVERFLOW ELEV. 396.00 OUTLET INVERT ELEV. 393.50 ORIFICE INVERT ELEV. 393.50 ORIFICE SIZE 1 1 /8"0 NOTE: FOR POND, ORIFICE, EMERGENCY OVERFLOW SIZING SEE SWPPP APPENDIX A. EROSION CONTROL NOTES 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON, PUBLIC WORKS DESIGN ENGINEER. 2. ALL LIMITS OF CLEARING AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY FLAGGED IN THE CY) FIELD AND OBSERVED DURING CONSTRUCTION. 00 3. ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE Cfl CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR N CONSTRUCTION TO ENSURE THAT SEDIMENT LADEN WATER DOES NOT O ENTER THE NATURAL DRAINAGE SYSTEM. ALL EROSION AND SEDIMENT O FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND T POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE IMPLEMENTATION, 0 MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITTEE. 4. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE PERMITTEE SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITTEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, CY) OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO (V PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE O RECEIVING DRAINAGE SYSTEM. O 5. APPROVAL OF THIS PLAN IS FOR EROSION SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR (� RETENTION FACILITIES. r 6. DURING THE TIME PERIOD OF OCTOBER 1ST THROUGH APRIL 30TH Q ALL PROJECT DISTRIBUTED SOIL AREAS GREATER THAN 5,000 SQUARE FEET, THAT ARE TO BE LEFT UN -WORKED FOR MORE THAN 12 J HOURS, SHALL BE COVERED BY MULCH, SODDING OR PLASTIC COVERING. 7. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE NO FURTHER WORK IS ANTICIPATED FOR A PERIOD 30 DAYS OR MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTING OR OTHER APPROVED EROSION CONTROL TREATMENT APPLICABLE TO THE TIME OF YEAR. GRASS SEEDING ALONE WILL BE ACCEPTABLE ONLY DURING THE MONTHS OF APRIL THROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED, HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE PERMITTEE, BUT MUST BE AUGMENTED WITH MULCHING, NETTING OR OTHER TREATMENT APPROVED BY THE LO CITY OF RENTON, OUTSIDE THE SPECIFIED TIME PERIOD. 0 8. FOR ALL EROSION/SEDIMENTATION CONTROL PONDS WHERE THE DEAD O STORAGE DEPTH EXCEEDS 6 INCHES, A FENCE IS REQUIRED WITH A O MINIMUM HEIGHT OF THREE (3) FEET, 3:1 SIDE SLOPES. O 9. A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE, 24 FEET X 50 FEET X 8 INCHES OF 4 TO 6 INCH QUARRY SPALLS SHALL BE LOCATED AT r ALL POINTS OF VEHICULAR INGRESS AND EGRESS TO THE CONSTRUCTION SITE. AS-BOIL T DRAWINGS N COMPLIANCE WITH CITY OF RENTON STANDARDS MEV 12-13-181 SURVEYED: LDC SCALE: AS NOTED ,�, „�;N3,1", DATU MCHECKED: %C T Y 0 RENTON V. Plan ning/Building/Public Works Dept. RENTON SPEC/AL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108TH AVE SE, RENTON, WA 98055 TESC NOTES AND DETAILS R-396206 08-17 DESIGNED: MEV DRAWN: NC ONE INCH rFIELDBOOK: -02 MEV AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY REVISION BY DATE APPR APPROVED: MEV OF: 23 I,'s C'7 00 (D N C) C) T AblJ co N C) C) C) C) T l H H • T • M Cp IT Viq, J Q ill N Cfl O C'7 O 0 420 W 410 w 400 U J Q 390 U W I0- U) z J80 O z W IIr ro �j W 420 410 400 J90 I 0 J80 0 N Io 01 N !n Q N Cr C 3 0 0 T COTTAGE D FF=410.50 / J1/ 1 2 / 1� 1 0 8" DI WATER MAIN 8" SANITARY SEWER MAIN SECTI N A A SCALE: HOR: 1"=10' VE : 1"=10' NOTES: 1. REFER TO STRUCTURAL DESIGN AS PART OF THE BUILDING PERMIT FOR THE RETAINING WALL. 2. STRUCTURAL DESIGN ACCOUNTS FOR SURCHARGE LOADING ON WALL. �/ 1 Ee RAGE D =410.50 10" DI WATER MAIN SECTION B-B SCALE: H R: 1"=10' V R: 1"=10' NOTES: 1. REFER TO STRUCTURAL DE -SIGN AS PART OF THE BUILDING PERMIT FOR THE RETAINING WALL. 2. LOWER WALL IS OUTSIDE THE ZONE OF INFLUENCE OF UPPER WALL BASED ON A 1:1 SLOPE FROM EDGE OF BUILDING FOUNDATION PE GEOTECHNICAL ENGINEER. C 7 E E 0 LIMITS OF FUTURE o RESTORATION BY "AVANA RIDGE" 14+79.13, 17.96' 0 o_ 1n 0 I♦ 420 410 400 J90 NOW STORM DETENTIOM CLEAN OUT ----- ' YARD DRAIN �— 410.50 :,; r:.:.::'' 410.20 — — ... \ ®'V:,, — ....................... ..... PERVIOUS PAVEMENT \ ,...........I........... .......... ....... ... ...;••�..• I �„ 45 50 •• :. ; : I � ........ . PROPOSED ASPHALT �,. � : , • 410.40 _ I� 30 EX R W I I405.32 IL I�44 a20% . COTTA06.00 G�B PROPOSED GRIND/OVERLAYCO7TAGEA , 15.5' R/W DEDICATON05.50 ., FLU I�I FF=410.5 FF=410.5 \ I 410.35 LIP _`4 ......... d- =,. 57 410.30 LP / PVMT .... ... ... UTILITY ESMT7 420 I— , I— �' ....... I .. ... 1 .. . .. I .. 44 I "..•.=�.;: .�.� i....1. I .. � a� NOTE 410 6' PERF PIPE DRAIN LINE 400 \1 /i CONNECT DRAIN LINE TO CONTROL STRUCTURE J80 20' CITY EMERGENCY ACCESS ESMT LIMITS OF FUTURE RESTORATION — BY "AVANA RIDGE" 16+45.93, 18.00' FUTURE PAVEMENT AND ROAD WORK BY "AVANA RIDGE" DEVELOPMENT co 0 N Call 2 Business Days Before You Dig 811 or 1-800-424-5555 O Utilities Underground Location Center 0 1 thANNIAMDCADV Surveying Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 0 AS —BUILT DRAWINGS MEV 12-13-18 SURVEYED: SCALE: LDC VERTICAL: NAVD 1988 DESIGNED: 1 " ■ _ r1201 HORIZONTAL: NAD 1983/1991 C T Y OF MEV RENTON DRAWN: OR NC ONE IN DATU M CHECKED: MEV AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: MEV SCALE ACCORDINGLY RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 GRADING PLAN R-396208 co 00 Cfl N O O T XJ N O O O T Q J T n `M LU U Q )4-08-17 IOOK: VG N0: R IS, R-01 Z 8oF: 23 oc NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON w rr Q U Q U n C/) z 0 z w rr m E 0 Co O I 0 N r7 0 N r) N 0 3 J n I rL' CD I Q U 7 m I Q U) 0) C 3 0 0 _T C E E 0 0 0 U V) 0 c rL' co i 0 N i c .3 0 0 , , , , , 0 — — _ SE 17OVD ST KEY MAP NOT TO SCALE 17+00 3� 398.45 jQR �F AVANA RIDGE SIDEWALK MATCH GRADES TO FRONTAGE IMPROVEMENTS EXISTING DRIVEWAY . . . . . . . . . . . . . . . . . . . . . . . . . . A SE 172ND STAND DRIVE A SCALE: 1" =10' Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 7 Q o 0 MINIMUM 4'X4' LANDING NOT TO EXCEED 2% RUNNING OR CROSS SLOPE. ALL SIDEWALK FOR DESIGN RAMPS SHALL NOT EXCEED 7.5% WITH 01.5% MAX CROSS SLOPE FOR DESIGN. UNLESS OTHERWISE NOTED (SEE NOTE 7). 3. ALL SIDEWALKS SHALL NOT EXCEED 1.5% CROSS SLOPE. 4. SEE SHEET DT-04 FOR CURB RAMP DETAILS. 5. ALL CURB ELEVATION AT FLOWLINE UNLESS OTHERWISE NOTED. 6. GB: GRADE BREAK LP: LOW POINT HP: HIGH POINT SCALE: 1" = 10' 10, 0 10, 20' - — — — 7. WHERE PEDESTRIAN ACCESS ROUTES ARE CONTAINED WITHIN A STREET '--_- OR HIGHWAY RIGHT-OF-WAY, THE GRADE OF PEDESTRIAN ACCESS ROUTES DR/VEA �. . _ 1 ------------- ----- SHALL NOT EXCEED THE GENERAL GRADE ESTABLISHED FOR THE ---________ ADJACENT STREET OR HIGHWAY. WHERE PEDESTRIAN ACCESS ROUTES ARE _ NOT CONTAINED WITHIN A STREET OR HIGHWAY RIGHT-OF-WAY, THE GRADE OF PEDESTRIAN ACCESS ROUTES SHALL BE 5 PERCENT MAXIMUM. AG 2012, SECT. R30 . . 413.70. _(PROW ----------=-==-=-- ---- I . . . . . . . . . . . ........... -------__- 411.4 ......... 411.35 411.18 TC ........ .: >...:: : ............... ................ ' ............... >: , •. 410.68 FL . . . . . . . . . . . . . . . . . . . . . . . . CURB RETURN #1 I----- I ................ �.' .� t . ............. �........... ............ - STA 10+ 4.8 �. ' .................. R=30.0' 22.00' LT , . , , 410:55 FL ... ............... \ I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L=45.24' rn ;------r---- Lon . ..:-.:-:-:-,-.',.=;'- `:._ __"_:_`._::-`. -- -- ' . 411.00 TC. . . . . .� . . . . . . . . . . . . . . . . . . 410 77 4'10.50 ' FL . . ,410.95 +� i 4�0.6y 108TH A VE SE AND DRIVE A - ' SCALE: 1 =10 cn __ 1 �� .: 410.38J' MATCH GRADES TO EXISTING SIDEWALK 1 thANNIAMDCADV Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com --------------------- ...................... ..................... ..................... TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER, 0 1 AS -BUILT DRAWINGS I MEV 12-13-18 NO. REVISION BY I DATE I APPR MATCH GRADES TO CONSTRU AVANA RIDGE SIDEWALK FRONTAGE IMPROVEMENTS AS-BUILT DRA WINGS N COMPLIANCE WITH CITY OF RENTON STANDARDS B SE 172ND ST AND 108TH AVE SE SCALE: 1" =10' SURVEYED: SCALE: DATE: LDC HORIZONTAL NQ ;M;1991 C RENTON SPEC/AL CARE COMMUNITY, LLC 04-08-17 DESIGNED: MEV AS NOTEDOR C T Y O R E N TO N RENTON SPECIAL CARE COMMUNITY FIELDBOOK: DRAWN: PAGE: NC 17033 108TH AVE SE, RENTON, WA 98055 DRAWING N0: ONE INCH DATU M CHECKED: MEV AT FULL SCALE Planning/Building/Public Works Dept. DETAILED GRADING PLAN GR-02 IF NOT ONE INCH APPROVED: MEV SCALE ACCORDINGLY R-396209 SHEEP: 9OF: 23 00 Cfl N 0 0 I\ T �] N 0 0 T Q J T n Cfl C'7 I 6 W W rr Q U J Q U W n z O z w rr C) T E 0 co 0 i 0 N 0 0 -o 0 n 3 J n 0 D_ Q ro c N a� m Cn Q C N C 3 0 0 _T C E E 0 0 0 U n CO 0 Lr CD i 0 N i U i 0 0 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center RIM=408.0 IE=405.50 45 LF 8" PVC 0 1.94% "s. • ,�i 36 LF E" PVC 0 8.97% z1_ 1�0 0 13 70D0275 CB-5, CONCRETE INLET , STA. 2+06.59, 16.74' LT 10' LANDSCAPE BUFFER 470 LF 8'0 STORMWATER DETENTION TANK SEE SHEET SD-01 FOR ADDITIONAL DETAILS 91 LF T PVC 0 2.177o 92-L�-rC� CB-4, TYPE-1 � ne i T . - i , 9 . i^7nTr STA. 1 +22.75, 9.43' LT 11 LF T PVC 0 1.50% SEE PAVEMENT SECTION ON SHEET RD-07 FILTERRA 10'X6' ENHANCED WATER lt7i QUALITY TREATMENT VAULT TA X PA -RC EL 28 LF T PVC 0 1. _ _ ONCREfE-VALLEY GUTTER a F�� 10 D D D 1 — STA. 3+52.74, 9.21 RT HEIGHT CONCRETE CURB a— — F OM STA 2+44 -STA 3+53.I::::::::::::::::::SEE DT-03 10' LANDSCAPE ................. .......... [ZERO FROM STA 3+53 - STA 4+63 �J N ....^ a BUFFER SEE DT-03 \ ...... 35 LF 8" PVC 2.80?� 30�...... r ^ 61 LF�PVCO TRW .. '\ I 07 157 CB-13, TYPE-2-48"� fL .. LL:/..... +1 UTILITY ESMT k RIM=410.35 COTTAGE B PVMT PVMT I 00 RIM=410.40 ,IE=408.25IE=404.14 :...:: ;.PE-2-48" - STA. 11 +43.01 47.61' ` .. MEECB-10, RIM=410.30 -.'. CB-9, TYPE-1 nL OCKING LID IE=403.68;;,_; ', IE=408.50 W/ SOLID LOCKING LID I .::.....: .::: = I 8. 20P i•'%nr: � �� ..a'=, :...:: .;. IE=408.50 . CTA 111nr,'n G7 CGS I TI I ,a_j ........ I ;._._. .... If .. ...... I....'.,_,_. .:N ....... NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON HOUSE / ( U) a I CB-15 TYPE-2-48"O CB-6, CONCRETE INLET is ' Lj W SOLID LOCKING LID Q C13-7, TYPE 1 STA. 2+43.95, 9.54 RT TAX PARCEL ,+A. S -,-r 9.2S' P+ STA. 4+14 03 814' RT � 115' 1 4 15 thANNIVERCA1?y Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com SCALE: 1" = 20' 20' 0 20' 40' LEGEND o STORM PIPE ------------ DRAIN PIPE ROOFLINE SEWER PIPE WATER PIPE ® DOWNSPOUT O STORM DETENTIOM CLEAN OUT O YARD DRAIN STOP SIGN PERVIOUS PAVEMENT PROPOSED ASPHALT PROPOSED GRIND/OVERLAY i- UTILITY CROSSING NOTES 1. ALL ROOF DRAIN PIPE IS 6" 0 AT 2.0% MIN SLOPE UNLESS OTHERWISE SPECIFIED. 2. SEE SHEET RD-02-RD-06 FOR ROAD AND STORM DRAINAGE PROFILES. 3. SEE SHEET SD-01 FOR STORM DRAINAGE DETENTION PIPE DETAILS. PIPE CROSSING TABLE STA 1 +23.22, 22.00' RT. (DRIVE A) 1 8" PVC PIPE BOTTOM=400.88 12" SS TOP=399.01 PIPE SEPARATION=1.87' STA 1 +23.22, 30.40' RT. (DRIVE A) 2 8" PVC PIPE BOTTOM=403.75 8" WATER TOP=402.25 PIPE SEPARATION=1.50' STA 16+98.98, 17.11' LT. (SE 172ND ST) 3 12" PVC PIPE=391.64 8" SS TOP=389.22 PIPE SEPARATION=2.42' STA 1 +23.22, 1.48' LT. (DRIVE A) 4 8" PVC PIPE=400.52 8' DETENTION PIPE TOP=399.00 PIPE SEPARATION=1.52' STA 2+10.17, 10.21' LT. (DRIVE A) 5 8" PVC PIPE=402.42 8' DETENTION PIPE TOP=399.00 PIPE SEPARATION=3.42' co 00 N O CD T co O O O O T Q J F5 H H 1 \ ._I -' / �� \�, IN COMPLIANCE WITH CITY OF RENTON STANDARDS Lull A S-B UIL T DRAWINGS TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 0 AS —BUILT DRAWINGS MEV 12-13flAP SURVEYED: LDC SCALE: DESIGNED: MEV 1 -20' HM W IN3i1991 uR % C TY OF RENTON SPECIAL CARE COMMUNITY, LLC RENTON RENTON SPECIAL CARE COMMUNITY DRAWN: NC 17033 108TH AVE SE, RENTON, WA 98055 ONE INCH DATU M CHECKED: MEV AT FULL SCALE Plan ning/Building/Public Works Dept. ROAD AND STORM DR�4/NAGEPLAN IF NOT ONE INCH NO. REVISION BY DATAPPROVED: MEV SCALE ACCORDINGLY R-396210 U Q W DAM 04-08-17 flElDB00K: O PAGE: DRAWING NO: RD-01 Z SHEET. 0F. 10 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N Cfl C'7 0 w w rr Q U J Q U w � /n �./ / Z 0 Z w rr T T E 0 co 0 I 0 N 0 0 0 a_ o, 3 I 0 I Q m I U) Q U) c 3 0 0 T E E 0 0 0 U 0 a V) 0 0 re i co i 0 N i U i c .3 0 0 420 400 J80 J60 J40 RETAINING WALL I 136 LF 12' PVC I \ I \ r CB -Al 6 .......... ................ ... �- 20 LF 127 PVC J I / CB -Al 7 S 102 LF 1t PVC --G-----G-V--- _RAISE LID TO FINISHED GRADE AND- -G REPLACE W/ SOLID LOCKING LID mm.; •*� it �� Mc= � I :*=_Z5`1&w=_ - kvt' �`,�+►7�� .9 l� 10. fWIMMER __-off r yr i SD - o ; o ...S.".......... l "- . ��. .... ... ... --- ........ � � o :.:ter .....::::::::::.r....:..:.::::: _. ......�........................................... 4- - .................... ....�. - ....................... SD S - - S cn LLJ �� 0 z 0LLJ zQ ��_ Go CD C) C I Cn �' V) - Z m O 60' VC - o C Z O O PVI STA= Coo 8+50.00 o o w Q0 + V) - o V) PVI EL K=6 404.06 w o+ o+ N <� Z cn cn -I n .83 CCD 0 o O o � + a' o CDOO °O + � o �aau ? ci c~n w Ln 0� CD °o - II CD O Q (n II J w LEI rn 00OC) CDC)CD � O Li l j 50- > co ODr M + rn Q C/n ICI w a 6.7�0% Q _j ¢ J Q S 4� c° O cn w 5.05% + - 3.61% - - - - - _ o FINISHED GRADE - - z AT ROAD 4.39% A EXISTING GRADE 4.33% - - AT ROAD CL - - _ 5.12% LF. - 1 102 L F. 12 PVC 0 2•6 9 0 1.92% - - 136 L.F. 12" SD 0 STA 16+60.57 2. 3' LT RIM=395.82 EXIST CULVERT IE=399.22 (12"0 CMP) E IE=392.65 (12"0) E EXISTING CULVER IE=390.65 (12"0) SW TO BE REMOVED EX un, I rrt 2-4 " C -1-A,i�+E TYPE 2-48*0 STA 15+58. 2, 2.22' RT W/ SOLID LOCKING LID W OPEN GRATE RIM=390.68 STA 17+96.7 , 16.93' LT IE=388.05 E RIM=401.94 FS RW_�96.ss- �ffflll� IE=387.89 2*0 NW +E---7j9'6.88U IE=395.91 (1 f0) W (1240-)­)AL AVANA RIDGE PROPOSED STA 1 +50.75, 17.75' LT CB-A17, PE 2-48" CB-1, TY E 2-48" RIM=3 1.04 W/ SOLID LOCKING LID W/ OPEN GRATE IE=38 .79 1 tO W „ O 16+86.26, 17.86' LT _ IE=38 .61 12"0 SE 12 LF. lt PVC 0 0.51 % - H RI=397.68 IE=38 .59 120 E _ µ �{,-�� IE 390.23 (12"0) E AVANA RIDGE PROPOSED IE 390.20 120) N, CB-A16, TYPE 2-60' CB-16, TYPE 2- " W/ SOLID LOCKING LID 20 LF. 1f 0 1.40% CURB INLET, SEE T-01 ' STA 16+60.18, 9.23' . RIM 396.83 ) - IE= 90.71 (12°0) N - "INI . - " IE= 90.59 (12"0) s - SE 17 ND ST EXISTING GRADE E FINISHED GRADE AT ROAD AT ROAD Q SCALE: HOR: 1" =20' ^7 rn co O VE N : 1"=10' to a, rn o rn O O O �, h , rn O , N Ln O � ►� oo o� o O o O N o rl op O 15+00 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 15+50 16+00 16+50 17+00 1 thANNIAMDCADV Surveying 0 AS -BUILT DRAWINGS Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com NO. 17+50 18+00 18+50 19+00 19+50 20+00 LEGEND STORM PIPE SEWER PIPE 420 WATER PIPE PERVIOUS PAVEMENT PROPOSED ASPHALT PROPOSED GRIND/OVERLAY NOTE 400 SEE SHEETS DT-01 THROUGH DT-03 FOR STORM DRAINAGE NOTES AND DETAILS. J80 J60 J40 'NOTE VERTICAL INFORMATION PROVIDED BY AVANA RIDGE APPROVED PROPOSED PLANS AS -BUILT ELEVATIONS MAY VARY. CONTRACTOR TO VERIFY ELEVATION PRIOR TO ORDERING MATERIALS. AS-BUILT DRAWINGS 00 N O T 5611 N O O 0 O T J IN COMPLIANCE WITH CITY OF RENTON STANDARDS UU TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS U BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE r FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. MEV 12-13-18 SURVEYED: LDC SCALE: DATE: DESIGNED: v, VERTICAL: NAVD • RENTON SPEC/AL CARE COMMUNITY, LLC AS NOTED HORIZONTAL: NAD 1983/183/1991 C TY 0 IC 04-08-1 7 MEV RENTON SPECIAL CARE COMMUNITY FIELDBOOK: PAGE: DRAWN: NC INCH OR RENTON 17033 108TH AVE SE, RENTON, WA 98055 DRAWING NO: ONE DATU M CHECKED: MEV AT FULL SCALE Plcnning/Building/Public Works Dept. ROAD AND STORM DR41NAGE PROFILES R D - 02 Z IF NOT ONE INCH REVISION BY DATE APPR APPROVED: SCALE SCALE ACCORDINGLY R-396211 SHEET: 1 1F: 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON N (0 C'7 O 0 W W rr LU U Q U n z O z W rr N T o, 3 q n I 0 o' I Q 0 m I Q i 0 0 _T C E E 0 0 0 0 U Q 0 o' QD i 0 N i i EL C 0 0 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center N 0 Q N 420 ��oN z orn U p0 U J + c+0 O � w LLI F_ Z V) N L J UJ 400 0 wl ZI J I I O I U7 CV M + C 06 O Co M I II N LJLLJ a a 5.022% 56 L.F. if SD 0 2.07% -7 1 r 9 n" c- n 4 7 Pf I C13-2, TYPE 2-54" CONTROL STRUCTURE J80 C13-1, TYPE 2-49 . SEE SE 172ND ST PROFILE, 6S SHEET RD-02 STA 0+73.64, 1.88' LT - . RIM=400.77 zn- cn IE=392.00 8"0) W - � - - - - IE=391.49 �lfO) N IE=391.36 1 f O S - 12 L.F. T PVC 0 31.96% C1373, ITYPE 1 W/ SOLID LICKING LID J60 STA 0+73.32, 13.40' LT . RIM=400.63 SS- IE=395.69 (TO) N,E - I THE PROFILE VIEW CALLS VV I so ■V� / ■ CROSSING # 1 STA. 1 +23.31, 21.98' RT. 12" SD IE=400.88 8" SS CROWN=399.01 SEPARATION=1.87' CDZ FINISHED GRADE CDM AT DRIVE AISLE J EXISTING GRADE w AT DRIVE AISLE 1 a 5.49%_ 0 WO DETENTION PIPE INLET-1 STA. 1 +27.14, 4.5 LT RIM--4e3-48- rdM=403.37 £8--48CB-10A, TYPE 2-48" W/ SOLID LOCKING LID ' STA 1 +31.38, 20.56' R RIM-484.86- RIM=405.11 - IE=391.57 (WO) N - IE=402.01 (8 O) E CB-4, TYPE 1 I S+A. 1 ,-- �, ' - STA 1 +22.75, 9.43' LT 3.19S RIM=403.02 IE=400.37 (TO) N,E,S 96" 0 DETENTION PIPE THE CONNECT ON FRC IM THE TANK TO THE OUT ET CONTROL STRUCTURE SHOULD BE 3 -IN MINI AUM PER ECTIO 5. 1 . . 1 OF TH SWD . WA THIS CHA GED T 12-1 OR IS TH S AN ERROR? 28 L.F. 8" PVC 0 1.80% 0 36 LF 6' PVC REFERENCE LINE SEE SHEET RD-04 0 o rn OIR r� ffj + + + O Q QJ C:) J V) Lj Lil (n Ed 3.33% 4.44% z � 91 LF g PVC 2.17% n I !' Ono r o rn r i o o F� C13-8, TYPE 2-48" STA. 1 +23.22, 41.27' RT. SEE COURT YARD, RP-06 INLET-2 STA. 1 +77.43, 5.5 R1 p4li- i es. is RIM=405.39 INLET-3 STA. 1 +77.47 15.5 RT R{#-;- MM=405.48 INLET-4 STA. 1 +87.14, 4.5 LT -- oRill! 186.68 RIM=405.51 MODULAR WETLAND OUTFALL MODULAR WETLAND INTAKE STA 1 +01.07, 13.59' LT . RIM=402.81 RIM---492.S RIM- CB-5, CONCRETE INLET J40 IE=396.18 (TO) S +E-�9 S - STA 2+06.59, 16.74' LT . STA 1+11.93, 11.50' LT RIM=405.76 6-9gr RIM=402.81 IE=402.42 EDRIVEA IE=400.21 (TO) INIE=402.35 �15'0�6'0S `F EXISTING GRADE FINISHED GRADE AT DRIVE AISLE AT DRIVE AISLE Z SCALE: HOR: 1"=20' VER: 1" =10' 3§ LF. 4" PVC ® 8. 7% O O O O O o O o O 0+00 0+50 15 thANNIVERCA1)y Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com WX 0 O, J80 Z 4 o W i v� Z~ N J60 ■ ■ ■ IJ40 ■ THIS IS NOTED AS 6-IN IN PLAN VIEW FOR TRASH INCLOSURE ROOF DRAIN -20' CITY EMERGENCY ACCESS ESMT 45 LF T PVC P'j --1 -rt I I SCALE: 1" = 20' (le) CID 20' 0 20' 40' N O O r NOTE T SEE SHEETS DT-01 THROUGH DT-03 FOR STORM DRAINAGE 0 NOTES AND DETAILS. I I LEGEND STORM PIPE SEWER PIPE WATER PIPE � CHECK DAM, SEE DETAIL SHEET DT-01 TOPOGRAPHIC DISCLAIMER I TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND 1+00 1+50 2+00 DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 0 AS -BUILT DRAWINGS MEV 12-13-18 SURVEYED: LDC SCALE: HORIZONTAL HAD ;N3719,1 C T Y 0 E DESIGNED: AS NOTED DRAWN: MEV RENTON NC ONE INCH DATUM CHECKED: MEV AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: MEV SCALE ACCORDINGLY PERVIOUS PAVEMENT N O PROPOSED ASPHALT OO PROPOSED GRIND/OVERLAY I CD AS-BOIL T DRA WINGS T Q J u� H n i N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108TH AVE SE, RENTON, WA 98055 ROAD AND STORM DRAINAGE PROFILES R-396212 U Q W DAM 04-08-17 flElDB00K: O PAGE: DRAWING NO: RD-03 Z sl+EEr: 2 123 N Cfl C'7 , 0 w w rr Q U J Q U w In 0 Z O Z w rr E 0 O i 0 N 0 0 -o 0 n 3 n n 0 ry i Q i m i Q 0) C 3 0 0 _T C E E 0 0 0 U V) 0 co O N 0 i CL C .3 0 0 36 LF 6" PVC 45 LF 8" PVC i IL i pF_ R" pvr- �P �� > 91 LF 8" PVC REFERENCE LINE SEE SHEET RD-03 TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. I � Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 440 420 400 Z 4 o W' Zw Ww Ww U_ w W `I-) J80 t.i 0 � O O LO o + N Orn r7 + O r- EXISTING GRAD a � AT DRIVE AISLE N "' w FINISHED GRADE a AT DRIVE AISL r+ TD TRESEE a --1.95%----- STA 3+15.83, 7.36' RT RIM=409.36 IE=404.93 8NE,W IE=40.94 6"0S CB-6 A, TYPE 1 0 6" MINIMUM SEPE ATION BETWEEN STORM PIPE AND WATER MAIN AT CROSSING 2 59% 61 LF. 12", SD ® 0.59 0 0 TRENCH DAM, SEE DETAIL THIS SHEET -TRENCH DAM, SEE DETAIL THIS SHEET CB-15, fYPE 2-48" 0 W/SOLID I LOCKING LID INLET-6 - STA. 2+53.42, 2.5 RT - }F-f RIM--488.14 RIM=408.25 " I LET-5 CONCRETE INLET TA. 2+48.42, 7.5 LT I LET-7 CB-7, RIM=408.36 TA. 2+98.59, 6.9 LT STA 3+52.74, 9.21' RT RIM=409.18 S RIM=40 .91 CB 6, CONCRETE INLET - IE=406.58 6"O) S ' ' STA 2+43.95, 9.54' RT - IE=405.91 W - IE=406.82 12 O) E RIM=407.98 IE=403.86 lr S IE=403.79 6"N IE=403.30 870 W,E 45 L.F. 8 PVC 01.94% DRIVE A SCALE: HOR: 1" =20' VER: 1" =10' raj O N "C� A CC' n^j� 2+50 3+00 15 thANNIAMDCADV Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0-� W N l� L'J DO W zl� II J + �I a 2 �Q ¢ 00 c ; cl o I-S N ZCs O I.- I �_ O � + W N Lur U N h7 Q J Z .. Cq O I Ln M C-� N 0) + M + M Q _j QLd J U) W a a I -2.01 % n 1.9 TRENCH DA SEE DETAIL A 4+14.03, 8.14' RT RIM=411.35 K- IE=407.18 (1ZO) V1,SE EXISTING GRADE AT DRIVE AISLE O N •� FINISHED GRADE AT DRIVE AISLE QL 3+50 4+00 4+50 5+00 0 AS -BUILT DRAWINGS MEV 12-13-18 SURVEYED: LDC SCALE: VORONfAL:.�HAD ;�i,�, DESIGNED: AS NOTED NORIZ MEV DRAWN: NC I ONE IN DATU M CHECKED: AT FULL SCALE MEV IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: MEV SCALE ACCORDINGLY 440 420 400 1' MIN FROM PAVING SURFACE J80 J60 CITY OF RENTON Planning/Building/Public Works Dept co W Cfl N O O co 0 O O T Q NOTE J SEE SHEETS DT-01 THROUGH DT-03 FOR STORM DRAINAGE NOTES AND DETAILS. LEGEND STORM PIPE SEWER PIPE ~ Ln WATER PIPE C) C) � CHECK DAM, SEE DETAIL SHEET DT-01 00 PERVIOUS PAVEMENT I PROPOSED ASPHALT T 0 PROPOSED GRIND/OVERLAY � n�n, in,n HOARSE MATERIAL BACKFILL UNDER VEMENT CH SIDEWALL CH DAM COMPACTED IAL TILL, CDF OR SIMILAR PERMEABLE MATERIAL M OR WATER PIPE TRENCH DAM DETAIL SCALE: NTS AS-BUILT M DRAWINGS N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPEC/AL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 ROAD AND STORM DR41NAGE PROFILES R-396213 U J Q W DATE: V l FIELDO0•- O 8 - 17 PAGE R GRAWNG NO: RD-04 Z SHEET. 3P 123 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N Cfl O C'7 O w w rr Q U J Q U w In 0 Z O Z w rr E 0 0 I O N 0 N 0 0 n 3 n n I 0 ry I Q i m I m Q m 0) C 3 0 0 _T C 7 E E 0 0 0 U 1n 0 re co i O N 0 i C .3 0 0 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center s s s 15 thANNIAMDCADV Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 440 420 400 J80 II w w Q p Co w Z N N Urc TN` N N + � �Ln F_ n ZICnn() L Jw EXISTING GRADE - AT SAWC T LINE 1.19% 0 TIC — — — — — — — — —416—_. V i EXISTING GRADE AT ROAD SCALE: 1" = 20' a . s a ° r 20' t .:. 0 20' 40' s : v WAS A N DYED REVISION TO aC E THIS WITH P NIVW :231�/M.: M: .... To NIdW :�glvNP'I'a : ,? l• I. p o :RETE INLET PER � 'LAN 200.30. WAS ' . : �, . ' N=166681.99 :�HAIVGEC7? : E=1303056.92 :::10+. 0 / 15 LF 12 PVC.....: :: 11:: :•: ::::::.:I:::::: i ::: :•: :.: :.: :. Oq N 0 N 0) N + w APPROXIMATE FINISHED GRADE LAT ROAD FLOWL114E 0.97% 1.57% — — .76% — A L.F. 12" SD 0 29 L.F. 12" i�iL CB-15 SEE DRIVE A PROFILE SHEET RD- 4 CB- 4, TYPE 2-48"0 W/S LID LOCKING LID STA 11 +71 49, 41.77' LT . RIM=413.2 IE=407.60 12°0) S,NW - " EXISTING GRADE FINISHED GRADE AT SAWCUT LINE Al ROAD A CB-13, TYPE 2-48" 0 . STA 11 +43.01, 47.61 ' LT RIM 411.62 S IE= 7.84 (12" O) KS SCALE: HOR: 1"=20 VER: 1" =10' OQ ef- II w Ln w o Q z N im O (w/) Z O O 0 U � � N (W CD CDO — CV In zl_� J STA 10 43.59, 21.23' LT RIM=41 .21 IE=408. 8 (12"O) W STA 10+46.85, 46.12' LT RIM=410.63 IE=408.36 12"O) E -IE=408. N 12+50 12+00 11+50 11+00 10+50 10+00 TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 0 AS -BUILT DRAWINGS MEV 12-13-18 SURVEYED: SCALE: LDC VERTICAL: NAVD 1988 ■ DESIGNED: AS NOTED HORIZONTAL: NAD 1983/1991 C TY OF MEV RENTON DRAWN: OR NC ONE INCH DATU M CHECKED: MEV AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: MEV SCALE ACCORDINGLY 440 NOTE SEE SHEETS DT-01 THROUGH DT-03 FOR STORM DRAINAGE NOTES AND DETAILS. LEGEND STORM PIPE SEWER PIPE WATER PIPE PERVIOUS PAVEMENT PROPOSED ASPHALT 420 PROPOSED GRIND/OVERLAY 400 J80 A S-B UIL T DRAWINGS co 00 co CD T WJ co N O O O O T J I H rS • H N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 ROAD AND STORM DR41NAGE PROFILES R-396214 OC U Q DATE: V l FIELDO0.— O 8 — 17 PAGE: R DRAWING NO: RD-05 Z SHEET: F. 14 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N Cfl O C'7 I O I Lw 1 w rr Q U J U In 0 Z O Z w rr L J T E 0 0 i 0 N 0 N 0 0 n 3 q n i 0 ry i Q i m i J) Q U) 0) C 3 0 0 _T C E E 0 c� 0 0 0 U 1n 0 re co i O O N 0 i c .3 0 0 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 440 420 400 J80 J60 L�J z w N � l LL,I > Of I w zl 0 0 I I I I I I I I APPROXIMATE I I I I FINISHED GRADE EXISTING GRADE I----_— — — —_--------- -- -- — — — — ----- ----- 200 L.F. 12 PVC 0 1.64% — — nnn n' nin mom 0 I / 51 L.F. 8" PVC 0 2.33%:1) 0 9 0 DETENTION PIPE CB-9, TYPE 1 P R STD. 235.00 SOLID LOCKING LID STA 11 +05.93, 67.66' LT (108TH AVE SE) - RIM=411.11 IE=407.42 4 0) S 0+41. 4 IE=406.42 1ZO) W C13-4, TYPE 1 CB-8, TYPE 2-45' ' STA 1 +24.10, 41.27' RT (DRIVE A) (DRIVE A) - - RIM=410.05 - +E-6 . IE=403.13 E - +E-19 . �1270) IE=401.56 TO) W STA 1 +22.75, 9.43' LT RIM=403.02 IE=400.37 (TO) N,E,S COURi YARD EXISTING GRADE SCALE: H R: 1"=20' V R: 1"=10' Ln N co O Ln O o� 0 0 0 N n 0+00 0+50 1+00 1+50 2+00 2+50 3+00 TOPOGRAPHIC DISCLAIMER 15 thANNIAMDCADV Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 440 SCALE: 1" = 20' 20' 0 20' 40' SEE SHEETS DT-01 THROUGH DT-03 FOR STORM DRAINAGE NOTES AND DETAILS. 00 Cfl N O T 56J cY) N O O O O I T J LEGEND STORM PIPE ~ Ln SEWER PIPE C) 420 WATER PIPE Q PERVIOUS PAVEMENT C) PROPOSED ASPHALT T PROPOSED GRIND/OVERLAY 400 J80 J60 AS-BOIL T DRA WINGS 1 IN COMPLIANCE WITH CITY OF RENTON STANDARDS W 0 AS —BUILT DRAWINGS MEV 12-13-18 SURVEYED: SCALE: LDC VERTICAL: NAVD 1988 83/1 RENTON SPECIAL CARE COMMUNITY, LLC DESIGNED: AS NOTED HORIZONTAL: NAD 193/1991 C TY OF MEV RENTON SPECIAL CARE COMMUNITY DRAWN: NC RENTON 17033 108TH AVE SE, RENTON, WA 98055 ONE INCH DATU M CHECKED: MEV AT FULL SCALE Planning/Building/Public Works Dept. ROAD AND STORM DR41NAGE PROFILES IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: MEV SCALE ACCORDINGLY R-396215 U Q DATE: V l FIELDO0.— O 8 — 17 PAGE: R DRAWING NO: RD-06 Z SHEET: 1 5F. �� N (0 O C'7 O 0 w w rr Q U Q U w In Z O Z w rr O I SOUTH r R/W E 0 0 i 0 N U N 0 0 n o, 3 n n i 0 ry i Q i m i U) Q U) 0) 0 L 0 _T C 7 E E 0 U 0 0 0 U N Q Cn 0 m r- co i O N i CL C .3 0 0 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON EAST WEST R/W R/W 1 82.5' R/W I I 5.5'± EX SIDEWALK 37'± EX R/W R/W 81f 0.22'± EX PVMT ill Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center TRAVEL LANE 30' EX R/W 5' 6' BIKE PARKING LANE 6' C� En 2.0% EX R/W 15.5' R/W DEDICATION I 0.5' 10.5' I 8' 4.5' ± WEST PVMT Sk 0.5' 10, 10, L- r SIDEWALK TRAVEL LANE TRAVEL LANE I �2.0% 0.5' 5, SIDEWALK I1.�% \-- 4" CEMENT CONCRETE WALK \_6" VERTICAL CURB AND GUTTER PER COR STD PLAN 102, TYP 6" VERTICAL CURB AND GUTTER 4" CEMENT CONCRETE WALK PER COR STD PLAN 101 6" COMPACTED DEPTH CRUSHED PER COR STD PLAN 101, TYP 2" ACP PER COR STD PLAN 102, TYP 8" ACP CLASS B SURFACING BASE COURSE 3" ATB 6" COMPACTED DEPTH CRUSHED 6" CRUSHED SURFACING TOP COURSE 5" AGGREGATE SUB -BASE SURFACING BASE COURSE SUITABLE NON -YIELDING SUB -GRADE SUITABLE NON -YIELDING SUB -GRADE 108TH AVE SE DRIVE A STA 11 +25.00 STA 1 +00.00 SCALE: 1" =5' SCALE: 1" =5' NORTH R/W 64.5' R/W I VARIES JUIIf11_JLL INUIV-IILLUIIVV JUU-VIVYIUL SE 172ND ST STA 18+25.00 SCALE: 1" =5' 1 thANNIAMDCADV Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. -TAINING WALL EE SHEET GR-01 )R WALL HEIGHT VERIFY IF THIS WAS UTILIZED. IT WAS CROSSED OUT ON THE REVISION PLAN THAT WAS SUBMITTED. SOUTH 5, 0.5' FS 1.5� 4" CEMENT CONCRETE WALK PER COR STD PLAN 102, TYP 6" COMPACTED DEPTH CRUSHED SURFACING BASE COURSE 6" VERTICAL CURB AND GUTTER PER COR STD PLAN 101, TYP 6" PERVIOUS PAVEMENT PER DETAIL SHOWN ON SHEET DT-01 20' VARIES EAST L. PVMT Z 10, L 10, PARKING TRAVEL LANE TRAVEL LANE 3I 2.0% 01 2.0% I '2.0% ZERO HEIGHT CONCRETE CURB PER DETAIL SHOWN ON SHEET DT-03 2 ACP 3" ATB 5" AGGREGATE SUB -BASE — SUITABLE NON -YIELDING SUB -GRADE DRIVE A STA 4+50.00 SCALE: 1"=5' VARIES EAST L WEST PVMT Z 0.5' 10, L 10, I. L TRAVEL LANE TRAVEL LANE I 2.0% I —2.0% 0.5' 5, SIDEWALK 1.5% 6" VERTICAL CURB AND GUTTER 4" CEMENT CONCRETE WALK J PER COR STD PLAN 101, TYP PER COR STD PLAN 102, TYP 5" PORTLAND CONCRETE CEMENT 6" COMPACTED DEPTH CRUSHED 4" CRUSHED ROCK BASE SURFACING BASE COURSE M RETAINING WALL 00 SEE SHEET GR-01 (D FOR WALL HEIGHT CV O O r UL RETAINING WALL SEE SHEET GR-01 FOR WALL HEIGHT �] cY) N O O O O r Q J SUITABLE NON -YIELDING SUB -GRADE DRIVE A CMP LIMIITED COVER NOTE: SEE SHEET RD-01 FOR �O SCALE: 1"=5' AREA OF EXTENT. 1 IN COMPLIANCE WITH CITY OF RENTON STANDARDS UU TOPOGRAPHIC DISCLAIMER oer oeC TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN A S-B UIL T DEVELOPMENT PROVIDED ONSU CORNERSTONE BY NT , INC.) ASSUMES/ NO LIABILITY AS TO (LAND HE ACCURACY AND OF THIS DATA. ANYES DfMWINGS BETWEEN WHAT IS SHOWN ONSTHE PLANS AND WHAT I SC N � EDC IN HE FOUND FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. MEV 12-13-18 SURVEYED: SCALE: LDC VERTICAL: NAVD 1988 DESIGNED: AS NOTED HORIZONTAL: NAD 1983/1991 C T Y OF DRAWN: MEV RENTON NC • ONE INCH DATU M CHECKED: MEV AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH REVISION BY DATE APPR APPROVED: MEV SCALE ACCORDINGLY U DATE: V l RENTON SPECIAL CARE COMMUNITY, LL C 000 — 0 8 — 1 7 RENTON SPECIAL CARE COMMUNITY FIELD PAGE: 17033 108THAVE SE, RENTON, WA 98055 DRAWING NO: ROAD SECTIONS R D- 0 7 Z R-396216 SHEET: 16 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N co O co O 96"0 CMP DETENTION PIPE AT 0.00% 0 LENGTH VARIES, SEE PLAN w � TOP OF PIPE EL-399.06 ,399-9� 36"0 ACCESS MANWAY, TYP 36"0 ACCESS MANWAY, TYP FINISHED GRADE VARIES, SEE PLAN AND PROFILE -\ TOP OF LIVER 398.73 100 YR WSEg398.54 50 YR WSE= -4 398.54 -______________________________ - _________________________ 10 YR WSE­3� 398.50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 YR WSE=44�- - 397.67 BEGIN LIVE STORAGE EL­3�391.49 - -_-- ------------------------------ - __________________ w BOTTOM OF PIPE EL�1-9� Ir 391.06 0.5 SEDIMENT STORAGE 36"0 CMP ACCESS LADDER, TYP 36"0 CMP 36"0 CMP -/ Q DETENTION PIPE - TYPICAL PROFILE U 2 L.F. 36 0 SD @ 0.00% SCALE: 1"=10' J Q ACCESS MANWAY PER COR 0 STD PLAN 235.10, w FINISHED GRADE VARIES, DETENTION TANK ACCESS 0- SEE PLAN AND PROFILE DETAIL, SEE PLAN FOR LOCATIONS, TYP 399 06 Z TOP OF PIPE EL=39 6� O TOP OF LIVE =38-398.73 0.5' FREE BOARD 1­_ 100 YR WSE�398.54 _ _ _ _ _ _ _ _ z 50 YR WSE�398.54 w 10 YR WSE=2'398.50 �� - ---- - - - -- - - - - - - Ir 2 YR WSE=39 397.67 E 0 co O I CD O N U 0) 0) O n on 3 J 0- I to 1 Q r r7 m I Q / m c 0 0 T E E 0 v 0 0 0 U Q C 0 Q) to i r,0 O N i C .3 0 0 BEGIN LIVE STORAGE EL=39�-56 391.49 391.06 BOTTOM OF PIPE EL=391.88 0.5' SEDIMENT STORAGE 36"0 CMP DETENTION PIPE - TYPICAL SECTION optional parallel tank ---------- 1 _ access dsers (max spacing shown below) inlet pipe (backup systems, where allowed) 2' min A O control structure SCALE: 1"=5' FOR 2 OR MORE ADJACENT PIPES IF- �- 7 1 I min. diameter same as inlet pipe A flow J 36" J Oinlet pipe (flow through) type 2 CB required access risers for flow, through system only PLAN VIEW NTS "Flow -through" system shown solid. Designs for "flow backup" system and parallel tanks shown dashed 2" min. diameter air vent pipe welded to tank (required if no access riser on tank) 50' max 100' max access risers ON sediment storage r� 36" min. size as required 2' min diameter (typ) control structure (PROP-Tshown) SECTION A -A min. 54" dia. Type 2 CB NTS "Flow -through" system shown solid. NOTE: All metal parts corrosion resistant. Steel parts galvanized and asphalt coated (Treatment 1 or better) zY + �► PUBLIC WORKS TYPICAL DETENTION TANK STD. PLAN - 235.00 f, NT DEPARTMENT MARCH 2O08 AS-BOIL T DRAWINGS 4 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 8' 0 DETENTION TANK PER COR STD PLAN 235.00 NOTE: CMP 10 GAGE OR BETTER. standard type 2-60" clam. CB concrete top slab 36" CMP riser -, standard locking compacted pipe bedding M.H. steps 12" O.C. weld or brit standard M.H. steps PLAN NTS SECTION NTS NOTES: 1. Use adjusting blocks as required to bring frame to guide. 2. All materials to be aluminum or galvanized and asphalt coated (Treatment 1 or better). 3. Must be located for access by maintenance vehicles. 4. May substitute WSDOT special Type IV manhole (RCP only). DETENTION PIPE SUMMARY CHART STORM LIVE STORAGE VOLUME (CF) RELEASE RATE (CSF) EVENT REQUIRED DESIGNED AS -BUILT REQUIRED DESIGNED AS -BUILT 2 YR 19,555 19,962 0 0.041 0.036 0.036 10 YR 22,267 22,827 22,267 0.074 0.058 0.0573 100 YR 22,352 22,894 22,352 0.098 0.093 0.09L2L] NOTE PI F1i-F VERIFY/UPDATE 1. SEE APPROVED BUILDING PERMIT 317004182 FOR ADDITIONAL I THESE NUMBERS CONSTRUCTION DETAILS FOR DETENTION PIPE INSTALLATION. frame locking lid (marked "DRAIN") mounted over 24" diam. eccentric opening maintain 1" gap between dtom of slab & top of .cr - provide pliable isket to exclude dirt riser, 36" diam. min., same material & gage as tank welded or fused to tank detention tank PUBLIC WORKS DETENTION TANK STD. PLAN - 235.10 DEPARTMENT ACCESS DETAIL MARCH 2O08 1 th A N N 1 T4'r- o C! A Ry Surveying 5 LD Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. REVISION 0 removable watertight coupling or flange frame &solid cover marked "DRAIN' with locking bolts 2" min. see note 3 elevation per plans 1' min. under pavement 16" max. g" T vertical bar � T gratefor max. 6" min. design W.S. secondary inlet v plate welded to elbow with orifice as specified elbow restrlctor, see detail ELBOW pipe supports handholds, steps or RESTRICTOR see Nole 6 ladder DETAIL 1.5 x D min. 2' min. T cutlet pipe inlet D see notes 1 & 1 dipa 2 shear gate with control invert and elevation rod for cleanoutPorein per plans -N 12" (rod bent as required for vertical alignment 12" with cover) o .E welded restrictor plate - 12" with orifice diameter as IF specified (not needed if for spill control only) /\ SECTION A -A 2' min. clearance to any portion of frop-T including elbows NOTES- A 1. Use a mimimum of a 54" diameter type 2 / catch basin. 2. Outlet Capacity: 100-Year developed peak flow. 3. Metal Paris: Corrosion resistant. elbow resbictor Non -Galvanized parts perferred. see detail Galvanized pipe parts to have asphalt treatment 1. 4. Frame and ladder or steps offset so: A. Cleanoul gate is visible from lop. B. Climb -down space is dear of riser and cleanout gate. C. Frame is clear of curb. 5. If metal outlet pipe connects to cement concrete pipe: outlet pipe to have smooth O.D. equal to concrete pipe I.D. less 4". 6. Provide at least one 3" X .090 gage support bracket anchored to concrete wall. (maximum T-0" vertical spacing) 7. Locate elbow restriclor(s) as necessary to provide minimum clearance as shown. S. Locate additional ladder rungs in structures used as access to tanks and vaults to allow access when catch basin is filled with water. A angle as necessary see note 7 addtional ladder rungs 2' min (in sets) to allow access to tanks or vaults when catch is filled with water �ZY � PUBLIC WORKS FLOW RESTRICTOR STD. PLAN - 237.00 DEPARTMENT OIL POLLUTION CONTROL �FN C TEE MARCH 2O08 12" 0 TO CB-1 REMOVABLE WATERTIGH COUPLING OR FLANGE 2" MIN. TO ELBOW 6" MIN. MAX PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED ELBOW RESTRICTOR RISER EL=398.73 RISER rl =zno �n D 1 /2" 0 ORIFICE r- IE=398.22 1-1/8"0 ORIFICE IE=397.28 4" ELBOW RESTRICTO SEE DETAIL, TYP I DISCHARGE TO CB-1 1 IE=391.36 12"� PIPE SUPPORTS - SEE NOTE 4 RESTRICTOR PLATE 1 /2"0 ORIFICE IE=389.50 EL=387.50 SEE DETAIL, ` v vDETAIL, TYP" PLAN 54"0 MIN ELEVATION CONTROL STRUCTURE CB-2 SCALE: 1"=2' TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. MEV 12-13-18 SURVEYED: SCALE: LDC VERTICAL: NAVD 1988 AS NOTED DESIGNED: HORIZONTAL: NAD 1983/1991 C TY O MEV RENTON ENTON NC ONE INCH DATU M • CHECKED: MEV AT FULL SCALE Plan ning/Building/Public Works Dept. IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY MEV ROM DETENTION PIPE SD C'7 00 Cfl O O T C'7 O O O O T Q J z 50 YR WS LO EL=398.47 O O O O I T n� FROM CB-3 1 FROM DETENTION PIPE IE=391.49 36 SHEAR GATE WITH CONTROL ROD FOR CLEANOUT/DRAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER) M N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 STORM DRAINAGE DETENTION PLAN R-396217 OC U Q UU DATE: C^ FIELDO00 .- O 8 - 1 7 ��♦♦ PAGE: O DRAWING NO: SD-01 Z SHEET: 7F: 17 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON N co m co 0 W W rr U Q U n Cn z 0 z W rr 00 0 00 0 m 0 N U N 0 n 3 J n I Q !n 7 m I N Q N IT C 3 0 0 E E 0 C) 0 0 U Q co 0 ry Q0 i 0 N 0 i s= .3 0 0 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center ........V. ......... ° a - - -- --- -- — c--------- ........ ° SCALE: 1" — 20' `\I I ............. --�-- I 0---------- —------- ------ -- mow— w -�---- _15' WATER_ -- ---- ���"� -DNWVEA— ' �— _; -----ESMTjc 20' 0 20' 40' I - - ... ....4+00 wW '- ---- - - - -- -- -- -- i— �- 00w NM I. . - LEGEND w c� fi x 12� ; ° 1 . POWER------- / ---- -- I � o 7r\�� Fr\r�r LE I I - - - - ESMT. STORM PIPE — r ,,/ , \ ' _— � \ � �------ - - - - -- DRAIN PIPE N r \ T \ SEWER PIPE I\ � ,TBR a \ — — — _ — \ .. — — WATER PIPE 10' LANDSCAPE J I — _ _ _ BUFFER I i o o o o E� 0 0 0 o i .. ® DOWNSPOUT o -- I ° O GAS LINE I _ — i-----=�__ - -- II ------------ s---- — --L--\ \h , . . . . . . . I . . . . . . . . . . . . . . . . . I ❑®G STORM DRAIN CLEAN OUT L ® ...... ......... .... 1 STREET LIGHT CABINET d� 15.5' R/W DEDICATIONI ... ......... .... TYPE I JUNCTION BOX CABINET W/ CONCRETE PAD I I I _ I I I E]ELECTRICAL SERVICE I 30 141 II III od tI II i iI I I E W PP UNDERGROUND POWER LINE 96 0 DETENTION PIPE COTTAGEA l � POWER VAULTPER STD. 235.00 o PVMT PVMT POST INDICATOR VALVE C I® + I I I I -- I N / 0 SIDE SEWER CLEAN OUT // Q STORM DETENTION 8p' ,--- �-- ----- I I a T ... � ° ,.I� ----- ROOFLINE - - - ----------------- FENCE - - -�- --- \ — — — — — — —� --------------� , .......... ... ... cn1 11,,.. --- W - - - - - - NEW ROADWAY LIGHT POLE I- I _ \ \ 1 +CO 2+001, _ _ �, a l /i NEW PEDESTRIAN LIGHT POLE ® 20' CITY - J ® - _ - - _ ------------ T - - - 3+00 EMERGENCY 110 - 6'x10' MODULAR WETLAND / ACCESS ESMT I _ _ _ _ r- - - - - _-_- -�_ _- - / NOTE / I I r------- ---------- ----- --�- ------ d _ 1. EXISTING 108TH AVE SE FRONTAGE OVERHEAD POWER TO BE REMOVED AND L - - �' �... . ° RELOCATED UNDERGROUND PER REQUIREMENTS SET FORTH BY PUGET SOUND / I - - - - - - I \� I S .......f ................. ENERGY AND CITY OF RENTON. .. s. S 2. MAINTAIN AND REUSE EXISTING STREETLIGHT ON EXISTING UTILITY POLE BEING I I I I I RELOCATED 22 FEET NORTHWEST 20' i i , �_ I I :. _. /. 3. REFER TO ELECTRICAL PLAN FOR LOCATION OF ONSITE ELECTRICAL ROUTING. 11 i I i II l� i 10' LANDSCAPE I I LIES 3.3' E. OF BUFFER PROPERTY LINE L� I i I I I I1Li 10 LANDSCAPE I I f BUFFER s =�-_ -- POWER POLE I — �� —-------------------- ----- J--�---- � — — — — ------ � I--i li TBIR °.d I- -------—_---- --- �— / LIES 4.2' E. AND I I -------------------------- ---Q-- -------------_ -� I .�..... ------------------ ---- 5.2' N. OF9 �. ........ / 110 — �- ................... °�2 ° PROPERTY LINE SD I 4 \ 1 \ — — — ESMT 4.5' R/W DEDICATION ------------ _ ��: - - - .............................. ° �L _-- .... --- — \ W ° 1 'N — c �y ....... ° o — I I� d 1 thANNIVEPCAQV Surveying Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. REVISION MEV 12-13-18 SURVEYED LDC DESIGNED: MEV DRAWN: NC CHECKED MEV BY DATE APPR wPRm:MEV SCALE: TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 1 " = 20' HOMMAL: HAD t9es/tssl ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CITY OF PRI RENTON Planning/Building/Public Works Dept. AS-BUILT DRAWINGS N COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108TH AVE SE, RENTON, WA 98055 COMPOSITE UTILITY PLAN R-396218 04-08-17 FIEUMM: ME DRAWING W: UT- 01 18 23 co 00 co N O O r W, u T n S-396201 W-396201 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N (C) O C'7 I 0 w W rr Q U U w �n V ) Z 0 Z W rr E 0 DO 0 I 0 N r7 U 0 0 -o 0 0 n Type 1 Curb Inlet Top Inlet Top Reinforcing ASTM / WSDOT requirements • All components #4 grade 60 reinforcing Inlet Top Conformity Standards Washington State APWA / WSDOT Standard Specifications WSDOT B-5.20.-01 Designed for a Type I, 1-L, or 1-P Inlet Top Components 24" Cast Iron Locking Frame & Cover w/ 2 %" x 3 %" x %" x 35 7/8" Galvanized Angle Iron 2 ea. #4 Trash Bars at 9" OC • 2" lift holes Weight 550 Ibs w/casting Type I Catch Basin [please see pg. 75, Type I Catch Basin for more details] 32" Catch Basins 0 Side View --------- STORM �v.Y.y w, `�� vVVC7 5" 8" Note: Drawings are not to scale. This is not a specialized "Shop Drawing." Designed for submittal purposes only. Sj' )^ Shope Enterprises, Inc. (253) 848-1551 1-800-422-7560 [Toll Free] 1 ' �IJ��/ 1618 East Main Avenue Fax Line 1 (253) 845-0292 www.shopeconcrete.mm concrete products Puyallup, WA 98372-3142 Fax Line 2 (253) 864-6172 NOTES 1. CHECK DAM OR INTERCEPTOR REQUIRED FOR LONGITUDINAL SLOPES > 2%. 2. SPACE CHECK DAMS BASED ON SLOPE TO ACHIEVE DESIGN AVERAGE PONDING DEPTH BEFORE OVERTOPPING DAM. 3. CALCULATE STORAGE VOLUME BETWEEN CHECK DAMS BASED ON CHECK DAM HEIGHT AND SLOPE FOR MODELING. 4. LONGITUDINAL SLOPE MAXIMUM VARIES WITH WEARING COURSE MATERIAL PER STANDARD DETAIL NDT-11 AND NDP-12. //\ COMPACTED SUBGRADE OR BASE Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 8" rluP-ru nAKA CPArINIC VARIP-C PLAN VIEW o� a0 F_ ZO oFW z0� z �a� 'WW 'v W (V a oZ ZZ 7 O SECTION A -A SDR 35 INLET COUPLING CAST INTO PRECAST VAULT WALL am 0 INLET COUPLING LOCATIONS TREE GRATE CLEAN OUT FRAME AND COVER CAST INTO TOP SLAB ENERGY DISSIPATION ROCKS SDR 35 INLET PIPE WITH BYPASS SLOTS SDR 35 INLET COUPLING FIE=400.11 �II o� � a0 L_ °� s z go LU q aL WW > N ?Z Z z O 6" UNDERDRAIN STONE LAYER, TYP. PROVIDED BY CONTECH 6" BYPASS INLET PIPE CONFIGURATION APPROXIMATE MAXIMUM BYPASS = 0.6 CFS DESIGNATION SIZE LENGTH WIDTH INLET/ OUTLET PIPE DIA. P UNDER- DRAIN PIPE DIA. (PERF.) TREE GRATE QTY. & SIZE FTIBP0404-6 4 x 4 4'-0' 4'-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBP0604-6 6 x 4 6'-0" 1 4'-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBPO606.6 6 x 6 6'-0" V-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBP0804-6 8 x 4 8'-0' 4'-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBP0806-6 8 x 6 8'-0' 6'-0" 6' SDR 35 4" SDR 35 (1) 4' x 4' FTIBP1006-6 10x6 10'-0" 6'-0" 6'SDR35 6"SDR 35 (1)4'x4' FTIBP1204-6 12 x 4 12'-0" 4'-0" 6- SDR 35 6" SDR 35 (2) Tx 3' FTIBP1206-6 12 x 6 12' -0" 6'-0" 6' SDR 35 6" SDR 35 (2) 4' x 4' FTIBP1307-6 13 x 7 13'-0" 7'-0" 6' SDR 35 6" SDR35 (2) 4' x 4' INTERNAL PIPING MAY VARY DEPENDING UPON INFLUENT LOCATION ' MAXIMUM TOP TO INVERT OUT = 5'-5' " MAXIMUM TOP TO INVERT IN = 2'-6" 6" PERVIOUS PAVEMENT WEARING COURSE 2" LEVELING COURSE 24" RESERVOIR COURSE 6" RUNOFF TREATMENT COURSE �j COMPACTED SUBGRADE OR BASE -CHECK DAM, NON -PERMEABLE MATERIAL 1' WIDE TYP. DAM TO EXTEND INTO NATIVE MATERIAL 1' ON EACH 6" SIDE, AND 6" EMBEDMENT. SLOTTED DRAIN PVC PER ASTM D1785 SCH 40 6" MIN SEPARATION BETWEEN BOTTOM OF CHECK DAM AND TOP OF WATER OR STORM PIPES PERVIOUS PAVEMENT CHECK DAM DETAIL SCALE: NTS 1 thANNIlir-QcADV Surveying 5 LDC1 Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com INI=11/YAO"Al A SDR 35 OUTLET COUPLING CAST INTO PRECAST VAULT WALL - PLANT PROVIDED BY CONTECH TREE GRATE AND FRAME CAST INTO TOP SLAB TOP SLAB 3" MULCH LAYER, TYP. PROVIDED BY CONTECH 02" IRRIGATION PORT. TYP. H 0 3 O m a. ~� Z Z O IE-397.20 �> ° " ' M ��W q 1qz alr V 7 V 1 21" FILTERRA MEDIA, TYP. 4",YPASSfUNDERDRAIN PROVIDED BY CONTECH O SDR 35 OUTLET COUPLING I FLOWKIT PROVIDED BY CONTECH 8" BYPASS INLET PIPE CONFIGURATION APPROXIMATE MAXIMUM BYPASS = 1.2 CFS UNDER- INLET/ TREE DRAIN DESIGNATION SIZE LENGTH WIDTH OUTLET GRATE PIPE DIA. PIPE DIA. (PERF.) CITY. & SIZE FTIBP0804 x 4 6' 4' 8" SDR 35 4" SDR 35 (1) 3' x 3' FTIBPOBD6 6'A X.SDR FTIBP080 8 -0" 0" 8"a-6 D 35 4" R (1) x FTIBPO806-6 x 8" SDR 35 8" SDR 35 I 4" SDR 3 I 6" SDR 35 ) 4' FTIBP1006-8 10 x 6 10'-0" 6'-0" 1 4' x 4' FTIBP1204-8 8" SDR 35 6" SDR 35 1 4 2' 4'- ' ( ' FTIBP1206-8 2 '-0" -0" 8" SDR 35 " SDR 35 (2) x ' FTIBP1307-6 x 1 -0" 7' 8" SDR "s5 SDR 3 ) 4' 4' INTERNAL PIPING MAY VARY DEPENDING UPON INFLUENT LOCATION * MAXIMUM TOP TO INVERT OUT = 6-5" xM"N V ** MAXIMUM TOP TO INVERT IN = 2'-6" * DIMENSIONS MAY VARY t r" DEPENDING f i lre «a ON PRECASTER BUILD CONFIGURATION. �,A"m,.,�M. "Eu,E"��"" E 92F 800 0 1 AS -BUILT DRAWINGS NO. REVISION MEV 12-13-18 SURVEYED: LDC DESIGNED: MEV DRAWN: NC CHECKED: MEV BY DATE APPR APPROVED: MEV D PLAN VIEW SECTION A -A I I A I I I 1i- _J 10" BYPASS INLET PIPE CONFIGURATION APPROXIMATE MAXIMUM BYPASS = 2.2 CFS UNDER- INLET/ DRAIN TREE DESIGNATION SIZE LENGTH WIDTH OUTLET GRATE PIPE DIA. PIPE DIA. (PERF.) CITY. & SIZE FTIBP0606-10 6 x 6 6'-O" 6'-O" 10" SDR 35 4" SDR 35 (1) Tx 3' FTIBP0806-10 8x6 8'-0" 6'-0" 10"SDR35 4"SDR35 (1)4'x4' FTIBP1006-10 10 x 6 10'-0" V-0" 10" SDR 35 6" SDR 35 (1) 4' x 4' FTIBP1204-10 12 x4 17-0" 4'-0' 10" SDR 35 6" SDR 35 (2) 3' x 3' FTIBP1206-10 12 x 6 12'-0" 6'-O" 10" SDR 35 6" SDR 35 (2) 4' x 4' FTIBP1307-10 13 x 7 I T-O" 7'-O" 10" SDR 35 6" SDR 35 (2) 4' x 4' INTERNAL PIPING MAY VARY DEPENDING UPON INFLUENT LOCATION ' MAXIMUM TOP TO INVERT OUT = 5'-5" " MAXIMUM TOP TO INVERT IN = Z-6" SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAW IN$ HORIZONTAL NAO 1983/1991 DATU M C TY OF RENTON • Plan ning/Building/Public Works Dept. SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. 3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS " C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES OVER AND UNDER PVC PIPE. 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT # 1 OR BETTER INSIDE AND OUTSIDE. 11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON PLANNING/ BUILDING/ PUBLIC WORKS ADMINISTRATOR. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA (APA). A S-B UIL T DfMWINGS C'7 00 (D N O O T co O O O I T Q J N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 NOTES AND DETAILS R-396219 OC U Q W DATE: OV l FIELD0.- O 8 - 17 PAGE: O DRAWING NO: R DT- 01 Z SHEEP: 19F: 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N co I W W rr U U W I� V J Z 0 Z W rr FRAME AND VANED GRATE 5 OR 12" ONE #3 BAR H�H01111OP FOR T HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT RECTANGULAR ADJUSTMENT SECTION �O p PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" CPSSP* 12" (STD. SPEC. 9-05.20) SOLID WALL PVC 15" (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15" (STD. SPEC. 9-05.12(2)) * CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES 1. As acceptable alternatives to the rebar shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specifications), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. #3 BAR EACH CORNER #3 BAR EACH SIDE #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR EACH CORNER 18" MIN #3 BAR HOOP 2. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification "4.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4. The frame and grate must be installed with the flange down. 5. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the precast base section. 7. All pickup holes shall be grouted full after the basin has been placed. 8. All grade rings and castings shall be set in mortar in accordance with Standard Specification "4.3. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION Y PUBLIC WORKS CATCH BASIN TYPE 1 STD. PLAN - 200.00 DEPARTMENT FNzp� MARCH 2O08 24" 3 � w O z w Do 3 BOLT -DOWN SLOT -SEE N c DETAIL AND NOTE 1 J _ �zvr A ODQO J 4pQpQ0 O Q Q 0�0�4�4 d00��4�0 040�OQ0� B TOP � 41 1 1ire SECTION OA 5" 314' y4• SIB' 4 3/4" DIAM. HOLE 1 1l4" 112" DIAM. HANDLE 5!8 SECTION O BOLT -DOWN SLOT DETAIL SEE NOTE 1 SECTION OB NOTES 1. Provide two slots in the cover that are vertically aligned with the holes in the frame. Location of bolt -down slots varies among different manufacturers. 2. Alternative reinforcing designs are acceptable in lieu of the rib design. 3. Refer to Standard Specification 9-05.15(2) for additional requirements 4. For Frame details, see City of Renton Standard Plan 204.00. ISOMETRIC Y STD. PLAN - 204.10 + PUBLIC WORKS RECTANGULAR SOLID DEPARTMENT METAL COVER FNzp� MARCH 2O08 A S-B UIL T DRAWINGS 1 � Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center m 3 FRAME AND VANED GRATE 4A ?O• 3p- 5" S• OR 12" ONE 93 BAR HOOP FOR 6' HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT RECTANGULAR ADJUSTMENT SECTION 7.d cA �sPFN?2° #3 BAR EACH CORNER #3 BAR EACH SIDE TOP AND BOTTOM ONE #3 BAR ACROSS BOTTOM PRECAST BASE SECTION Ica BAR EACH CORNER 18" MIN. #3 BAR HOOP SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" CPSSP* 12" (STD. SPEC. 9-05.20) SOLID WALL PVC 1 . (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15- (STD. SPEC. 9-05.12(2)) * CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES 1. As acceptable alternatives to the rater shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specifications), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. 2. The knockout diameter shall not be greater than 18". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-D4.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4. The frame and grate may be installed with the flange up or down. The frame may be cast into the adjustment section. 5. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the precast base section. 7. All pickup holes shall be grouted full after the inlet has been placed. + �► * PUBLIC WORKS CONCRETE INLET STD. PLAN - 200.30 f,=$ DEPARTMENT Nz MARCH 2O08 m 0 O 7 ❑ U ❑ O W 2 F w Q K 0 z O LL O ❑UTFALL TO STREAM DU P ND PDLLUTI TOP NOTES 1. Provide two slots in the grate that are vertically aligned with the holes in the frame. Location of bolt -down slots varies among different manufacturers. 2. Refer to Standard Specification 9-05.15(2) for additional requirements. 3. The thickness of the grate shall not exceed 1 518". 4. Unless otherwise specified, vaned grates shall be used With standard frame in the travel way, gutter or shoulder. vaned grates shall not be located within crossroads. Use vaned grates along rolled curbs. Dz 0 0 0 ISOMETRIC D \� SLOT - SEE DETAIL \ AND NOTE 1 318" (9mm) RECESSED LETTERING C 3l4" BOLT -DOWN SLOT DETAIL SEE NOTE 1 Y STD. PLAN - 204.40 A �+ PUBLIC WORKS RECTANGULAR DEPARTMENT HERRINGBONE GRATE `f'gN tp� MARCH 2O08 1 thANNI"1111i D C A DV Surveying Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. REVISION 8 CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) m HANDHOLD N RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION fO v GROUT, TYPICAL (SEE NOTE 5) U FLAT SLAB TOP aF i O 48'.54', BO', 72',84' OR 9B' - MORTAR (TYP.) N STEPS OR LADDER `v� z Xs MORTAR FILLET V � 2 � REINFORgNG STEEL (TYP.) GRAVEL BACKE LL FOR 12' GRAVEL ZONE BEDDING SEPARATE BASE INTEGRAL BASE CAST -IN -PLACE PRECAST WITH RISER "O" RING 12' GRAVEL -E ILL FOR B= • PIPE ZONE BEDDING SEPARATE BASE PRECAST CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS BASE REINFORCING STEEL in21ft IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE 48" 4" 6" 36" 8" 0.23 0.15 Sa" 4.5" 8" 4T 8" 0.19 0.19 60" 5" 8" 48" 8" 0.25 0.25 72" 6" 8" 60" 12" 0.35 0.24 84" 8" 12" 72" 12" 1 0.39 0.29 96" 8" 12" 84" 12" 1 0.39 0.29 NOTES 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning. 3. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5' maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 5 All rade rtn s risers and castin s shall beset in mortar in accordance with PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER BASIN DIAMETER CONCRETE ALL METAL CPSSP CI SOLID WALL PVC CI PROFILE WALL PVC a 46" 24" 30" 24" 27" 30.. 54" 30" 38" 30" 27" 36" 60" 36" 42" 36" 36" 42" 72" 42" 54" 42" 84" 1 54" 1 60" 1 54" 36" 48" as- 1 so" 1 72• 1 60" 36• 48" 9 9 9 ;i I Corrugated Polyethylene Storm Sewer Pipe (Sid. Spec. 9-05.20) Standard Specification 9-04.3. z, (Std. Spec. 9-05.12(1)) (Std. Spec. 9-05.12(2)) Y PUBLIC WORKS CATCH BASIN TYPE 2 STD. PLAN - 201.00 �FN t01 DEPARTMENT MARCH 2O08 1/2' [13mm] LETTERING BOLTHOLES - 3 PLCS EQUALLY SPACED 12/Y N4TS - DRAINS T APART ON 231l16" (566mm) DIA B.C. sT� �9 3 RENTON AHEAD OF THE CURVE DRAIN (1) V (25mm) DIA PICKHOLE ® 1 11r [32mm] LETTERING PLAN VIEW 25" DIA. [635mm] 1" [25mm] 3/4' [19mm] B 3/a" 110 [64 [222mm] [64mm] TYP COVER SECTION VIEW 26 1/2"DIA [673mm] 25 1/4" DIA [641 rim] 111191 1/4" (6mm) DIA [27mm] NEOPRENE GASKET 8 }T [152mm] 5B' J 2331W DIA CL OPEN [16mm] [594mm] 27 5116' DIA [694mm] 34 118" DIA [867mm] FRAME SECTION VIEW COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 50-111 X 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4" 1 vll6. [6mm] 1� [27mm] 118" [3mm] 1/8" [R3mm] GASKET GROOVE DETAIL NOTES ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRON WORKS INC. No. 3717C1 OR APPROVED EQUAL. Y STD. PLAN - 204.50 eL + PUBLIC WORKS STORM ROUND FRAME AND COVER DEPARTMENT `fgNtp� MARCH 2O08 MEV 12-13-18 SURVEYED: LDC DESIGNED: MEV DRAWN: NC CHECKED: MEV BY DATE APPR APPROVED: MEV SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZOMAL• NAD 1983/1991 DATU M 911111111� BOLT -DOWN HOLE (TYP.) - 51ff'- 11 NC, SEE DETAIL & NOTE 2 O TOP NOTES 1. This frame is designed to accommodate 20" x 24" grates or covers 2. Provide two holes in the frame that are vertically aligned with t he grate or cover slots. Tap each hole to accept 24 1I4" a 5/8' - 11 NC x 2" alien head cap screw. B Location of bolt down holes varies among different manufacturers. 3. Refer to Standard Specification 9-05.15(2) for additional requirements. SECTION O RECESSED ALLEN HEAD CAP SCREW 7/8"_I 1/8" 5/8"-11 NGx 2" I[�I tea" GRATE ISOMETRIC VIEW C a FRAME a a M 2112" SECTION DETAIL O BOLT-DOWN2DETAIL SEE NOTEY PUBLIC WORKS RECTANGULAR FRAME STD. PLAN - 204.00 DEPARTMENT `f'gN tp� MARCH 2O08 #6 BARS @ T SPACING 20". 24', 24" DIAM., 48" DIAM. M. J OR 54" DIAM. HOLE 2" (TYP) 4-- 12 Ll V MIN. 1/2" MAX. 84" or 96" FLAT SLAB TOP Y� ti #5 BARS @ 6" SPACING 20" x 24', 24" DIAM., 48" DIAM.::::::, OR 54" DIAM. HOLE 2„ (TYP TYPICAL ORIENTATION _- j � FOR ACCESS AND STEPS .1 L 71"MIN. 2 V2" MAX. 7r' FLAT SLAB TOP z� #4 BARS @ 6" SPACING z 20" x 24" OR 24' DIAM. HOLE 2 (TYP) 48"MIN. ,.. V MIN. 2112" MAX. ECCENTRIC CONE SECTION 4W', 54", or 60" FLAT SLAB TOP 12" [TYP.) a 6" 12" PREFABRICATED LADDER 12" MIN. o a STEP 5 �6" OR 12" ci�NE #3 BAR HOOP T ONE #3 BAR HOOP FOR 6' 4" TWO #3 BAR HOOPS FOR 12" ]J `1" RECTANGULAR ADJUSTMENT SECTION CIRCULAR ADJUSTMENT SECTION 1.0 As an acceptable alternative to rebar, wire mesh having a minimum area of 0.12 square inches per foot may be used for adjustment sections. Y STD. PLAN - 204.60 A �+ PUBLIC WORKS MISCELLANEOUS DETAILS FOR DEPARTMENT DRAINAGE STRUCTURES `f'gN tp� MARCH 2O08 C TY OF 1;%R] RENTON • Plan ning/Building/Public Works Dept. 00 0 T �J M rt� W 1 N COMPLIANCE WITH CITY OF RENTON STANDARDS UU RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 NOTES AND DETAILS R-396220 OC U Q W DATE: OV l FIELD0.- O 8 - � 7 PAGE: O DRAWING NO: DT-02 Z SHEEr: OF: 20 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N co O co 0 W w rr Q U J Q U UJ IMn V ) z O z w rr T N GREEN RESERVED WHITE PARKING BLUE REFLECTIVE SIGN CONSTRUCTED OF ALUMINUM STATE DISABLED PARKING PERMIT SIGN TO BE CENTERED AT THE REQUIRED INTERIOR OF END OF PARKING SPACE GREEN AREA OF SIGN TO BE ALUMINUM VA WHITE A MIN 70 SQ IN ACCESSIBLE DESIGNATED FOR "VAN ACCESSIBLE" AIX. WHERE APPROPRIATE MUST BE LLI MOUNTED AT 60" HIGH MIN FROM CD Q FLOOR OF PARKING SPACE FOR o � FREE STANDING SIGNS ; L1 CD � z oY • 00� L� Q C o • PARKING SIGN - "VAN ACCESSIBLE" NOT TO SCALE FACE OF CURB [ 61/2"_ 5 112" r 1 112" R. % 124 TOP OF 112• R. ROADWAY ° CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB 6 1/2 FLUSH WITH GUTTER — PAN AT SIDEWALK RAMP ENTRANCE r 124 / TOP OF 112" R f ROADWAY I\ f DEPRESSED CURB SECTION AT SIDEWALK RAMPS } �6" CEMENTCONCRETE 1/2" R. I I 1.• R SIDEWALK RAMP VARIES ` OR LANDING FROM 6'TOD ° 6'•I D D . . DD. _ 316" PREMOLDED JOINT FILLER CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB 61W SEE DEPRESSED CURB DETAIL THIS SHEET 1:24 TOP OF L__ gyp• 112"R.� ROADWAY 2 D D n V. il J DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 1G4.2 FACE OF CURB FACE OF ADJACENT CURB \ GUTTER SURFACE 6 112" I - 5 1/2" I (..1" 112" R. 11" R, �— TOP OF ° ROADWAY D a S_ • 1" R. 71" RCEMENT CONCRETE TRAFFIC CURB D D DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES: 1. See standard plans 102 and 10 1. 1 for curb expansion and contraction joint spacing. 2. Not used. 3. For Depressed Monolithic Driveway Curb & Gutter Section, see Standard Plan 1042 STD. PLAN - 101 PUBLIC WORKS DEPARTMENT CEMENT CONCRETE CURBS PR Dlih f N T A T( GreldZimmerman. Public Works Administrate Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center BLUE WHEEL STOPS IN ADA PARKING STALLS HANDICAP SIGN DIMENSION CRITERIA SIGN HEIGHT LOCATION REQUIREMENT ON POLE MIN. 60" TO BOTTOM OF SIGN ON BUILDING MIN. 36" TO BOTTOM OF SIGN PLACE VAN -ACCESSIBLE SIGN UNDER HC SIGN (SEE PLAN) SEE PARKING SIDEWALK OR SIGN DETAIL PLANTER I 01 ///0 N A • � 6' PE o PARK PARK NO N PARKING AND 8' MIN 8' MIN 12" WHITE PAINT PAINT WHITE LOGO 4" BORDER ON LIGHT BLUE FIELD (3%3') TYP SEE STANDARD DETAIL NO HARKING VAN ACCESSIBLEAND HANDICAP PARKING SPACE DETAIL NOT TO SCALE RKING BUMPER ERED IN NG SPACE) I'-0" 1'-0• ISEE CONTRACT) ROU DING jl 1/2" pM R, (TYP.) CURB NOT INCLUDED IN BID ITEM - SEE RAISED EDGE 3E'[INI PREMOLDED ,•"�L 1' "0SIDEWALK DETAIL - THIS SHEET JOINT FILLER ALL CUT MIN. (SEECONTRACT) =LOPES tn" IIN) R. (TYP.I WITH RAISED EDGE P J� 1 15k URB NOT INCLUDED IN BID ITEM - 3/8" pNl PREMOLOEJ.\ FINISHED GRADE 1'(aJ! BELOW JOINT FILLER V TOP OF CONCRETE SURFACE 2'-0' SIDEWALK ADJACENTTOCURB 1._D. 1._0. MIN. (SEE CONTRACT) ROU DING Ill" (IN) R. MP.) 1 _ r CURB NOT INCLUDED IN BID ITEM - —2.0% 15x ;�`, .: • 3B"QNI .•1,;T�i WALLORBARRIER BRIDGE OR PEDESTRIAN PREMOLDED RAILING JOINT FILLER ADJACENT TO CURB BARRIER - SEE SIDEWALK (STEEP FILL SLOPES) CONTRACT PLANS (SEE CONTRACT) WALL OR BARRIER I I U2" (INI R. (TYP.) FLUSH I CURB NOT INCLUDED IN BID ITEM- SIDEWALK �...Iaaa,,,......,,, 1,5% 1r2•II IR. VERTICAL WALL - 3/8• IIN) PREMOLDED BE DETAIL JOINT FILLER(TYPJ F311R ADJACENT TO CURB AND RAILING OR WALL D SIDEWALK BUFFER STRIP (BEE CONTRACT) ISEE NOTE 101 712" (IN) R. SIDEWALK ADJACENT TO WALL DETAIL 15% MIN. CURB NOT INCLUDED IN BID ITEM - B• Is, y+:+-:s'+: •ir. :fir .. -- LEVEL 17 FINISHED GRADE 1- (IN)BELOW TOP OFCONCRETE SURFACE FOR PLANTING -FLUSH IF PAVED ' ADJACENT TO BUFFER STRIP b"' 1' IINI R. �'•' GROOMED FINISH • �• ' 4" WIDE, SMOOTH O, A'•� TROWELED PERIMETER RAISED EDGE DETAIL 1� EXTEND SIDEWALK TRANSVERSE a' JOINTS TO INCLUDE RAISED EDGE A -tlt I 1 CEMENT CONCRETE CURB 7 (v (CURB AND GUTTER SHOWN) NOT IN IN BID ITEM �• For NOTES see STD PLAN 104.2. E �x Paved surfaces must comply with STD PLAN 102.1 as applicable. / 318" Z 178" TO 114" CONTRACTION JOINT - IN SIDEWALK ONLY EXPANSION JOINT IN BOTH • •• •0 •. •� G�•) •. CURB AND SIDEWALK(5EE5TDFlAN 101 11 ••�'•� '�'P •�• �'P O: JOINT AND FINISH PREMOLDED DETAIL JOINT FILLER� EXPANSION JOINT �C.' CONTRACTION JOINT STD. PLAN - 102 �'e \ PUBLIC WORKS CEMENT CONCRETE DEPARTMENT SIDEWALK PPRO 'ED: SVT 114 ATE If 1 thANNI'%ir-QcADV Surveying Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. REVISION Gregg Zimmerman, Public Works Administrator MEV 12-13-18 SURVEYED: LDC DESIGNED: MEV DRAWN: NC CHECKED: MEV BY DATE APPR APPROVED: MEV COMPACTED SUBGRADE OR BASE 3" ASPHALT TREATED BASE (ATB) 2" HOT MIX ASPHALT (HMA) NOTE: PAVING MATERIALS SHALL CONFORM TO WSDOT SPECIFICATIONS FOR 1/2-INCH CLASS HMA AND CRB. ASPHAL T PA VEMENT DRI VE AISL ES NOT TO SCALE 4" AGGREGATE BASE 4" CONCRETE SIDEWALK 2% MAXI COMPACT SUBGRADE TO NOTE: 95% AND REMOVE ANY CONTROL JOINTS @ 10' OC MAXIMUM. LOOSE MATERIAL CONCRETE SIDEWALK DETAIL NOT TO SCALE 4" AGGREGATE BASE 6" CONCRETE SIDEWALK 2% MAX m,— 3" 77 770707— WWF 4 GRID COMPACT SUBGRADE TO 95% AND REMOVE ANY LOOSE MATERIAL CONCRETE SIDEWALK FOR TRAFFIC NOT TO SCALE PAVEMENT PAVEMENT �i 3.5 WWF 4" GRID CONCRETE 18H\/� COMBACEED SUBGRADE ZERO HEIGHT CONCRETE CURB NOT TO SCALE SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD IM HORIZONTAL NAD IN3/1"I DATU M C TY OF 1;R] RENTON • Plan ning/Building/Public Works Dept. PAVEMENT PAVEMENT WWF 4" ID CONCRETE \�jj\ j\\\j/ j\�j/\\j/ COMPACTED SUBGRADE OR BASE 18" 18" CONCRETE VALLEY GUTTER NOT TO SCALE PAVEMENT SURFACE NOTE: CONTROL JOINTS @ 10' OC MAXIMUM. SEE SPECIFICATIONS FOR REQUIREMENTS. VERTICAL CONCRETE CURB DETAIL NOT TO SCALE 4" DEPTH CONCRE SAME AS SIDEWALI' CONCRETE REINFORCED Ek TRUDED CURB RADIUS NOT TO SCALE AS-BUILT DIMWINGS CY) 00 Cfl N O O T C'7 N O O O I T J P H H H t� V t� I N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 NOTES AND DETAILS R-396221 U J DATE: OV ll FIELD0.— O 8 — 17 PAGE: O DRAWING NO: DT-03 Z SHEET: 2 1 23 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N co I UJ W rr U J Q U ^W I��../^L� VJ Z Z W rr N E 0 0) 0 I 00 E N U N 0 3 r 0 I I Q r m Q U) C 0 L 0 T E E 0 U 0 0 U 0 U 0 i? Cn 0 D_ r- co i N i C .3 0 0 w A 4' - D" MIN. - SEE CONTRACT PLANS C3 CEMENT CONCRETE ::i PEDESTRIAN CURB - ErSEE NOTE 9 LANDING CURB RAMP CEMENT CONCRETE PEDESTRIAN CURB - LL I NOTE 9 m CURB RAMP DETECTABLE WARNING SURFACE - / C SEE STANDARD PLAN F 45.1D `` / / / MATCH SIDEWALK (4' - 0" MIN.) -SEE ol, CONTRACT PLANS CEMENT CONCRETE I DEPRESSED CURB AND PEDESTRIAN CURB _ 3/8" IN EXPANSION JOINT P. '- ( ) (TYP.) GUTTER -• SEE NOTES 4 & 6 SEE NOTE 9 - 1 SEE STANDARD PLAN F-30.10 CEMENT CONCRETE BUFFER STRIP (TYP.) - CEMENT CONCRETE CURB CURB AND GUTTER 6 D SEE CONTRACT PLANS AND GUTTER - SEE NOTES 4 & 6 SEE NOTES 4 & 6 DETECTABLE WARNING SURFACE- CROS WALK DEPRESSED CURB AND GUTTER- DETAIL SEE STANDARD PLAN 1-45.10 SEE NOTES 4 & 6 CURB RADIUS DETAIL PLAN VIEW TYPE COMBINATION WITH BUFFER 4'- 0" MIN. CEMENT CONCRETE SEE CONTRACT PLANS PEDESTRIAN CURB - SEE NOTE 9 _7 W LANDING NOTES 1. At marked crosswalks, the connection between the curb ramp and the roadway must be contained within the width of the crosswalk markings. 2. Where "GRADE BREAK' is called out, the entire length of the grade break between the two adjacent surface planes shall be flush. 3. Do not place Gratings, Junction Boxes, Access Covers, or other appurtenances on any part 3" R. of the Curb Ramp or Landing, or in the Depressed Curb and Gutter where the landing (TYP) connects to the roadway. 4. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb, Curb and Gutter, Depressed Curb, Gutter and Pedestrian Curb details. 5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and placement of sidewalk. 6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. 7. The Curb Ramp length is not required to exceed 15 feet (unless otherwise shown in the Contract Plans). When applying the 15-foot max. length, the running slope of the curb ramp is allowed to exceed 8.3%D. Use a single constant slope from bottom of ramp to top of ramp to match into the sidewalk over a horizontal distance of 15 feet. Do not included the abutting landing in the 15-foot max. measurement. When a ramp is constructed on a radius, the 15-foot max. length is measured on the inside radius along the back of the walkway. 8. Curb Ramps and Landings shall receive a broom finish. See Standard Specifications 8-14. 9. Pedestrian Curb may be omitted if the ground surface at the back of the Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will not be material to retain. LEGEND SLOPE IN EITHER DIRECTION GRADE BREAK 15' - 0" MAX. (TYP.) 4'- 0" MIN. 15' - 0" MAX. (TYP.) * 1.5 OR FLATTER RECOMMENDED FOR DESIGN/FORMWORK (2% MAX.) GRADE SEE NOTE 7 SEE CONTRACT PLANS SEE NOTE 7 * * 7.5% OR FLATTER RECOMMENDED FOR BREAK JC* COUNTER SLOPE TOP OF GRADE BREAK GRADE BREAK DESIGN/FORMWORK (8.3°/D MAX.) 5 0% MAX. ROADWAY f DEPRESSED CURB AND GUTTER -CURB RAMP CURB RAMP SEE STANDARD PLAN F-10.12 CURB RAMPLANDINGAND NOTE 6 1 C®v ��'t .3/8" (IN) EXPANSIONYP.) - SECTION OA SEE STANDARD PLAN F-30.10 SECTION 1O CONTRACTION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 (ALONG INSIDE RADIUS AT BACK OF WALKWAY) FOR CURB RAMP LENGTHS GREATER THAN 8'- W PROVIDE CONTRACTION JOINT EQUALLY SPACED 4'- 0" MIN. OC. "CEMENT CONCRETE CURB RAMP TYPE A COMBINATION" PAY LIMIT - SEE NOTE 6 DETECTABLE WARNING SURFACE 15' - 0" MAX. SEE STANDARD PLAN F-45.10 SEE NOTE 7 CURB RAMP 4'- 0" MIN. T - 0" MIN. (TYP.) SEE CONTRACT PLANS SEE CONTRACT BUFFER PLANS STRIP TOP OF * ROADWAY .p D CEMENT CONCRETE CURB AND CEMENT CONCRETE PEDESTRIAN GUTTER SEE NOTES 4 & 6 CURB (TYP.) - SEE NOTE 9 SECTION B ISOMETRIC VIEW TYPE COMBINATION PAY LIMIT pp WASyf���� z �® 28680 �V4 �F �0I STUR� �� ssI®NAL Zeller, Scott Jun 24 2016 7:20 AM COMBINATION CURB RAMP STANDARD PLAN F-40.14-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION CmrenL,,, Jeff �QTGfLCMZPIE. � J"n2920I6228PM �a STATE DESIGN ENGINEER Washington State Department of Transportation NOTES F A- 1. The Detectable Warning Surface (DWS) shall extend the full width of the curb ramp, -I B C DETECTABLE WARNING landing, or other roadway entrance as applicable. Exception: If the Manufacturer of I E MIN. MAX. CURB RAMP, LANDING, CUT- SURFACE (DWS) the DWS requires a concrete border around the DWS, a variance of up to 2 inches I THROUGH OR WALKWAY SEE NOTE 3 on each side of the DWS is permitted. �� A 1.60" 2.40" f _ B 0.65" - 2. The Detectable Warning Surface (DWS) shall be placed at the back of curb, with the A B D C 0.45" 0.90" two leading corners of the DWS panel placed adjacent to the back of the curb, and E� D o.s° 1.40" BACK OF CURB - """"""""" with no more than a 2 inch gap between the DWS and the back of the curb measured Q - z' - U MIN. - at the center of the DWS panel. Exception: If the Manufacturer of the selected DWS T TRUNCATED DOME SEE NOTE 2 TYP. OF ALL E 02' 112" requires a concrete border around the DWS, a variance of up to 2 inches from the A APPLICATIONS back of the curb is permitted (measured at the leading corners of the DWS panel). SECTION O TRUNCATED DOME SPACING 3. The rows of truncated domes shall be aligned to be perpendicular to the grade SEE NOTE 3 SEE STANDARD SPECIFICATIONS FOR COLOR OF SURFACE break at the back of curb. 4. The rows of truncated domes shall be aligned to be parallel to the direction of travel. TRUNCATED DOME DETAILS CURB AND GUTTER MATCH TO WIDTH OF CURB RAMP LANDING, CUT -THROUGH OR 5. If curb and gutter are not present, such as a shared -use path connection, the o a WALKWAY Detectable Warning Surface shall be placed at the pavement edge. m DETECTABLE WARNING SURFACE DETAIL 6. See Standard Plans for sidewalk and curb ramp details. LANDING OFFSET CURB RAMP SEE NOTE 8 7. If a curb ramp is required, the location of the Detectable Warning Surface must be at LANDING the bottom of the ramp and within the required distance from the rail. WALKWAY WIDTH OF WALKWAY 8. When the grade break between the curb ramp and the landing is less than or equal to WALKWAY WALKWAY WIDTH of CUT- 5 ft. from the back of curb at all points, place the Detectable Warning Surface on the THROUGH (TYP.) bottom of the curb ramp directly above the grade break. DETECTABLE WARNING W SURFACE (DWS) - WIDTH OF CUT -THROUGH a o SEE NOTE 4 CURB RAMP J (TYP-) Of BACK OF CURB W SINGLE DIRECTION CURB RAMP FLARE FLARE ' m (GRADE BREAK BETWEEN CURB AND MIN. LANDING15 5 FT. FROM BACK OF CURB) (SEE NOTE 6) DETECTABLE WARNING DETECTABLE WARNINC BACK OF CUR!B;- LANDING SURFACE (DWS) - SURFACE (TYP.) - W Y DIRECTION OF SEE NOTE 2 SEE NOTE 3 SEE NOTE 3 TRAVEL WIDTH OF CURB RAMP BACK OF CURB CURB RAMP SEE NOTE 2 PERPENDICULAR CURB RAMP WALKWAY WIDTH OF WALKWAY (SEE NOTE 6) ISLAND CUT -THROUGH WIDTH OF CURB RAMP, DETECTABLE WARNING LANDING, OR WALKWAY SURFACE (TYP.) - JI, 0" MIN. URB - 2 ?' - 0" MIN. DETECTABLE WARNING SEE NOTE 3 I... A.tttt'cI 0 WAS& `L SURFACE (DWS) - SEE NOTE 3 BACK OF CURB - BACK OF CURB - SEE NOTE 2 SINGLE DIRECTION CURB RAMP DETECTABLE WARNING (GRADE BREAK BETWEEN CURB AND SURFACE (DWS) - LANDING > 5 FT. FROM BACK OF CURB) SEE NOTES 4 & 7 (SEE NOTE 6) CURB RAMP r CURB RAMP WALKWAY LANDING r WALKWAY DETECTABLE WARNING BACK OF CURB SURFACE (DWS) - SEE NOTE 3 SEE NOTE 2 WIDTH OF LANDING PARALLEL CURB RAMP (SEE NOTE 6) I � Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center PATH OR •�•• WALKWAY PEDESTRIAN RAILROAD CROSSING z SEE NOTE 2 MEDIAN CUT -THROUGH o Z p o iv WIDTH OF SHARED - Zia USE PATH OR ®:�40� cl STY��� WALKWAY (TYP.) sst®NAL G WIDTH OF CUT -THROUGH Zeller, Scott SHARED -USE Jul 12 2016 4:25 PM (T� P•) PATH OR WALKWAY DETECTABLE WARNING ROUNDABOUT SPLITTER SURFACE ISLAND PAVEMENT SHOULDER EDGE STANDARD PLAN F-45.10-02 ........... SHEET 1 OF 1 SHEET DETECTABLE WARNING APPROVED FOR PUBLICATION SURFACE (DWS) ewenLeT,Jeff SEE NOTES 4 & 5 L"ns zoTe2_zePM STATE DESIGN ENGINEER w� PLACEMENT GUIDELINES SHARED -USE PATH CONNECTION Washington State Department of Transportation 1 thQAIAII11IDCARy Surveying Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. REVISION LANDIN( GRADE BREAK SEE CONTRACT PLANS - 4' - 0" MIN. CEMENT CONCRETE SIDEWALK - SEE NOTE 5 FLARE (TYP.) 3/8" EXPANSION JOINT TYP. - SEE STANDARD PLAN F-30.10 GRADE BREAK CURB, OR CURB AND GUTTER -SEE NOTE 4 FACE OF CURB MEASURED PARALLEL TO CURB (TYP.) LU Z IX W LL m Z SLOPE TREATMENT - SEE STANDARD PLAN F-30.10 A CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH A NOTES CURB RAMP WIDTH -SEE CONTRACT PLANS CURB RAMP WIDTH 4'- 0" MIN. 1. At marked crosswalks, the connection between the curb ramp and the road - LANDING TO MATCH CURB RAMP way must be contained within the width of the crosswalk markings. LANDING I WIDTH - SEE CONTRACT PLANS Y I GRADE BREAK I 2. Where "GRADE BREAK" is called out, the entire length of the grade break CURB RAMP GRADE BREAK between the two adjacent surface planes shall be flush. SEE CONTRACT PLANS - CEMENT CONCRETE 4' - 0" MIN. SIDEWALK - SEE NOTE 5 I 3. Do not place Gratings, Junction Boxes, Access Covers, or other appurten- I ances on any part of the Curb Ramp or Landing, or in front of the Curb PROVIDE SMOOTH TRANSITION Ramp where it connects to the roadway. TO SIDEWALK WIDTH 2' - 0" (TYP.) SEE CONTRACT PLANS - MIN. SEE CONTRACT 4. See Contract Plans for the curb design specified. See Standard Plan * _ 4'- 0" MIN. * PLANS -• 4'- 0" MIN. F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and 3/8" EXPANSION _ BUFFER WIDTH - MATCH Pedestrian Curb details. JOINT TYP. - SEE w TO CURB RAMP DEPTH I CURB RAMP STANDARD PLAN F-30.10 I (TYP.)5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See vt I Contract Plans for width and placement of sidewalk. V, GRADE `I' BREAK TRANSITION TO SIDEWALK BUFFER, IF 6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include the PRESENT, OR TO BACK OF CURB (TYP.) - " adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, Pedestrian SEE CONTRACT PLANS D w Curb, or Sidewalks. cc........... �� w 7. The Curb Ramp length is not required to exceed 15 feet (unless shown CURB, OR CURB CEMENT CONCRETE otherwise in the Contract Plans). When applying the 15-foot max. length, T AND GUTTER - I SEE PEDESTRIAN RIATE 4N CURB - the running slope of the Curb Ramp is allowed to exceed 8.3%. Use a DETECTABLE WARNING SURFACE - SEE NOTE 4 B I single constant slope from bottom of ramp to top of ramp to match into SEE STANDARD PLAN F-46.10 DETECTABLE WARNING SURFACE - the landing Over a horizontal distance of 15 feet. DO not Include the FACE OF CURB SEE STANDARD PLAN F-45.10 abutting landing in the 15-foot max. measurement. DEPRESSED CURB AND GUTTER - DEPRESSED CURB AND GUTTER 8. Curb Ramps and Landings shall receive a broom finish. See Standard CROSSWALK SEE NOTE 4 CROSSWALK Specifications 8-14. 9. Pedestrian Curb may be omitted if the ground surface at the back of the Curb Ramp and/or Landing will be at the same elevation as the Curb O CONTRACTION JOINT (TYP.) SEE STANDARD PLAN F-30.10 Ramp or Landing and there will not be material to retain. FOR CURB RAMP LENGTHS GREATER THAN 8'- 0" PROVIDE PLAN VIEW CONTRACTION JOINT EQUALLY SPACED 4'- 0" MIN. OC. PLAN VIEW TYPE PERPENDICULAR A TYPE PERPENDICULAR B LEGEND DETECTABLE WARNING SURFACE - (SHOWN WITH BUFFER) SEE STANDARD PLAN F-45.10 SLOPE IN EITHER DIRECTION GRADE BREAK DESIGN/FORMWORK 5 OR FLATTER RECOMMENDED MAX.) FOR 4' - 0" MIN. 15' - 0" MAX. (TYP.) * ° SEE CONTRACT PLANS SEE NOTE 7 COUNTER SLOPE COLA MAX. 7.5% OR FLATTER RECOMMENDED FOR * GRADE BREAK DESIGN/FORMWORK (8.3% MAX.) D * * TOP OF ROADWAY 9.5% OR FLATTER RECOMMENDED FOR DESIGN/FORMWORK (10% MAX.)®�IT p. p. LANDING CURB RAMP vEL �pF WAit Syf��3� DEPRESSED CURB AND GUTTER - 1 SECTION SEE STANDARD PLAN F-10.12 OA a CEMENT COCRET CEMENT CONCRETE CURB RAMP 'TYPE CEMENT CONCRETE CURB RAMP "TYPE �0 $ 2868o PEDES RIIANNCURBE PERPENDICULAR "A" PAY LIMIT - SEE NOTE 6 �� PERPENDICULAR "B" PAY LIMIT - SEE NOTE 6 A� �� -'cI STY�� SEE NOTE 4 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F-45.10 3" R. TYP. DEPRESSED CURB AND GUTTER - SEE NOTE 4 CEMENT CONCRETE CURB AND GUTTER SEE NOTE 4 CURB RADIUS DETAIL ISOMETRIC VIEW TYPE PERPENDICULAR A PAY LIMIT BID REIA 1INCLUDES SIOEWAIK RMIPS &'MIN. VAtOESISEENOtET) rNIN. ISEE NOTE S)) 18EE NOTE &) IO LF OF PAVED r ORNEWAY REQUIRED M-EXPANSION JOPJT (TY'P.) CEMENT STO. PLAN I011 CCEMEMERETE sroewALK SEE NOTE 5 } RAND WITR 1T11V SEENOTET CEMENT CONCRETE SLOPE ITYP CURBB1. YY I(.EE FGIGUTE E IR Yrca+mACTION.IOMT:I (SEE STOPI-19) PLAN VIEW (TYPE C3 SHOM, C1 & C2 & CaAA%SIMILAR) ISEE NOTE 9) VARES (SEE NDTE 10) &3%MAX SEE NOTE E 0-I. "MIN. 10' MIN C-MENTCONCRETE 1P AtIN. SIDEWALK N6' E%PANSINT (TYP.( SECTION OA (SEE ETD. PLONJOIAN IOiI SIDEWALK WIDTH _1 r DIFFERENCE IN SLOPE ur R( YPA DRIVEWAY W! SRNE SLOPE ISLOPC SNOWNE%AGGEW.TEO) Is _ t SI4 r'-1- �f Is" MIN• NEtTDIPE 6EEDETAKONSTDPLANIN2 SECTION OB .p-���� � � CEMENT CONCRETE �Y -N-UTTER }J IGEE NOTE 3) NHIC LELIENT cum & R CRETE JUL BTD PLAN 1. 21 SIOEWALK TYPE C2 - ISOMETRIC VIEW For NOTES see STD. PLAN 104.2 PUBLIC WORKS I CEMENT CONCRETE DRIVEWAY DEPARTMENT ENTRANCE - TYPES C1, C2, C3, and C-MAX MEV 12-13-18 SURVEYED: LDC DESIGNED: MEV DRAWN: NC CHECKED: MEV BY DATE APPR APPROVED: MEV SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY STD. PLAN - 104 VERDCsi: NAw IM HMZOMAL• t1AD IN13/1"I DATU V ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT RIDITEM(INCLUDESSIDEWAI_K WAPS� I EM EE EWALK �1 CCN TRUCTION JOINT RAI.IP WITH tIH 1V / SEE NOTEI CEMENT CONCRETE SLOPE ITYP.1 / B CUR6EENO�R Ye•CCNTRACTwxmINT (!WI JJJ I.EETD. PLAN t s1I PLANVIEW _VARIES ISEE NOIi t�) R 311.- SEE NOTE RITYPI .I r WAIN O'lAIN CEMENT CONCRETE fi'MIN DEPRESSE-UFE&GUTTFR BIDEY/ALK Le'E%PANSIOM JOINT RYPI (SEE NOTE 31 .tx� SECTION OA IREE STD. PLAN 1021 YI IDM DIFFERENCE IN SLOPE NVUt- DRIVEwAVWJP bltNE bLOPE ISLOPE bHOWN EXAGGERATED) t6Y. S,% . DPIVEvlAY rMIN r. I.nl DRNEWAYWIRELATIVE N - BE ON O NEGATNE SLOPE ISLIP, l SHOWN E-GGERATEOj CEMENTCONCRETE CURB & GUTTER (SEE NOTE 3) GEMENT DONLREE S ONDLITHL SOEWALI( CUR& JTTER ETAIL STD PLAN -.2, TYPE RIB - ISOMETRIC VIEW (RESIDENTIAL, WITH BUFFER) For NOTES STD PLAN 104.2 ti Y o STD. PLAN - 104.3 PUBLIC WORKS CEMENT CONCRETE DRIVEWAY DEPARTMENT PPR VED: ENTRANCE -TYPE R16 / 2 N f Ar[ -- -- - E MIN. VARIES ISEe NOTE T 6 Mu+-- (SEENOTE 51 (SEE NOTE R) to LF OF PAVED OP.PlEWAY REOUIREO ]16' EXPANSION /DINT (iYP.I (SEE STD. PUN I'+31 LE GONCF Sq I L � REE NOTES rc g�l C TY OF RENTON • Plan ning/Building/Public Works Dept. �J®NAL Zeller, Scott Jun 24 2016 7:20 AM C seN PERPENDICULAR CURB RAMP STANDARD PLAN F-40.15-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION �1� Carpenter, Jeff �'4L7� rej, /"ND 1un292016228PM STATE DESIGN ENGINEER Washington State Department of Transportation W N Q IN co I T- Q J I OM • H AS-BUILT M DRAWINGS N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 NOTES AND DETAILS R-396222 U J DATE: OI� FIELD0.- O 8 - � 7�♦ PAGE: O DRAWING NO: DT-04 Z SHEEP: OF: 22 23 C'7 00 (D N C) C) T WE a J l H • PC T Wil, J Q W Z Z Z Z Z Z Z Q Q Q W Q U J Q U w 13- W Z O Z W Ir E a 03 N r� i Do 0 N d5 0 n a� 0 a TREE INVENTORY Calip LD 54" above Dripline No. 'Grade Radius Botanical Name Co Health & Condition Rating Name (1 low - 5 high) Health & Condition Description Numerous water shoots on trunk, weak 1 30 12' Populus trlcocarpa Black Cottonwood 3 wood, branch and litter drop. Multi -stem* 6 trunks, a few downward 2 11"M** 18' Acer macrophyllum Big Leaf Maple 3 arching branches. 3 1 12" 8' Pseudotsuga menziesii Douglas Fir 3 4 5 28" 10"** 28" 6' Pseudotsuga menziesii Acer macrophyllum Douglas Fir Big Leaf Maple 5 1 6 18" 8' Pseudotsuga menziesii Douglas Fir 3 7 8" 5' Acer macrophyllum Big Leaf Maple 2 8 8" M 8' Acer macrophyllum Big Leaf Maple q 9 14" 10, Pseudotsuga menziesii Douglas Fir q 18" I 11, IThuja plicata IWestern Red Cedar 1 3 11 30** 1 12' Pseudotsuga menziesii Douglas Fir 3 12 30" 20' Pseudotsuga menziesii Douglas Fir q 13 I 20" I 8' JPseudotsuga menziesii IDouglas Fir I 3 14 1 10" 1 8' (Pseudotsuga menziesii IDouglas Fir I 2 15 22"M**I 15' JAcermacrophyllum Bigleaf Maple 2 16 20" 8' Pseudotsuga menziesii Douglas Fir q 17 12" M 12' Acer macrophyllum Bigleaf Maple 2 18 20" 15' Pseudotsuga menziesii Douglas Fir q 19 14"** 12' Pseudotsuga menziesii Douglas Fir q 20 12" 6' Pinus nigra Austrian Pine 3 21 16" 6' Pinus nigra Austrian Pine 3 22 18" 6' Pinus nigra Austrian Pine 3 23 16" 6' Pinus nigra Austrian Pine 3 24 20" 6' Pinus nigra Austrian Pine 3 25 I 12" 6' Pinus nigra Austrian Pine 3 26 8" 10, Tsuga heterophylla Western Hemlock 3 27 10" 10, Tsuga heterophylla Western Hemlock 3 28 8" 10, Tsuga heterophylla Western Hemlock 3 29 I I 10" 10, Tsuga heterophylla Western Hemlock 3 30 24" 21' Pseudotsuga menziesii Douglas Fir q 31 24" 21' Pseudotsuga menziesii Douglas Fir q 32 14" 10, Thuja plicata Western Red Cedar 4 33 26" 11' Pseudotsuga menziesii Douglas Fir q 34 46" 35' Acer macrophyllum Bigleaf Maple 5 35 14" 10, Pseudotsuga menziesii Douglas Fir 3 36 32" 18, Pseudotsuga menziesii Douglas Fir q 37 32" 15' Pseudotsuga menziesii Douglas Fir 3 38 24" M 16, Acer macrophyllum Bigleaf Maple 3 39 12" 6' Acer macrophyllum Bigleaf Maple 2 40 12" M 10, Acer macrophyllum Bigleaf Maple 3 41 12" 9' Acer macrophyllum Bigleaf Maple q 42 12" ** 9' Acer macrophyllum Bigleaf Maple 3 43 12" 5' Pseudotsuga menziesii Douglas Fir q 44 24" 25' Pseudotsuga menziesii Douglas Fir 5 45 24" 20, Thuja plicata Western Red Cedar 3 46 18" M** 12, Acer macrophyllum Bigleaf Maple q 47 10" 10, Acer macrophyllum Bigleaf Maple 3 48 1 12" 12, Tsuga heterophylla Western Hemlock 1 49 20" 8' Pseudotsuga menziesii Douglas Fir q 50 I 10" I 5' AAcer macrophyllum Bigleaf Maple I i 51 32" 1 12, Acer macrophyllum Bigleaf Maple 1 52 18" 18' Malus pumila Apple i 53 12" 12' Malus pumila Apple 2 54 12" 15, Malus pumila Apple 1 55 12" 10' Acer macrophyllum Bigleaf Maple q 56 10" ** 10' Malus pumila Apple 1 Several dead limbs, phototropic lean Good condition. Broken central leader, minor dead wood, downward growing branches. Growing into tree #4. Significant hole at base, deadwood in canopy. Multi -stem 3 small stems in addition to main trunk. Minor dead wood in canopy. Significant broken branch, trunk is forked at mid point, several broken branches. Several dead limbs, trunk is girdled near base, straight and strong central leader. A few dead limbs, straight and strong central leader Numerous dead limbs, straight central leader, thin canopy. Broken central leader. Multi -stem 5 stems - 6"-10" calip each. Growing into base of tree #16. Crack in one trunk, several dead limbs. Straight central leader, a few small dead limbs. Tree #15 is growing into base. Multi -stem 4 stems - 6"-10" dia. Several broken trunks, mis-shapen/singled sided canopy. Strong central leader, some dead wood in canopy Slight phototropic lean Broken central leader, some dead wood. Straight leader, thin canopy, low aesthetic value. Straight leader, thin canopy, low aesthetic value. Straight leader, thin canopy, low aesthetic value. Straight leader, thin canopy, low aesthetic value. Straight leader, thin canopy, low aesthetic value. Mis-shapen canopy (one-sided). Mis-shapen canopy (one-sided). Mis-shapen canopy (one-sided). Mis-shapen canopy (one-sided). A few dead limbs. A few dead limbs. Nails in trunk A few dead limbs, small second trunk A few low hanging limbs Mis-shapen canopy (one-sided), leaning, a few broken branches A few broken limbs Mis-shapen canopy (one-sided). Multi -stem 6" to 8", slightly mis-shapen. Broken limbs, cracked trunk, phototropic lean Multi -stem, phototropic lean, slightly mis-shapen. Thin canopy, but overall good form Thin canopy, but overall good form Very minimal canopy Good overall form Canopy is bare at crown indicating possible defect of ailment Multi -stem 4 trunks 5" -8" dia. Good leader, but several dead branches Poor health and poor canopy condition Mis-shapen canopy Mis-shapen trunk - was once a multi -stemmed tree but several trunks have been removed leaving a large stump with one remaining trunk Mis-shapen trunk - was once a multi -stemmed tree but several trunks have been removed leaving a large stump with three remaining trunks Poor health and poor canopy condition, possible indications of disease Poor health and poor canopy condition, possible indications of disease Poor health and poor canopy condition, possible indications of disease Straight trunk, good overall form Poor health and poor canopy condition, ;bl d NE 114 OF THE SW 114 AND 5E 1/4 OF THE NW 1/4, SEC 29, TWN 29, RGE 5 E, KING COUNTY, WASHINGTON Removal due to Significant Tree Hazard or Priority (RMC Landmark proposed Remove / 4.4.130) Tree R.O.W. Retain Hazard / Landmark R.O.W. Remove 2.ii. R.O.W. Remove Hazard / R.O.W. Remove 1.v. R.O.W. Remove Hazard / R.O.W. Remove 2.ii. R.O.W. Remove Hazard / R.O.W. Remove 2.ii R.O.W. Remove 2.ii. R.O.W. Remove Hazard / R.O.W. Remove Hazard / R.O.W. Remove i. I Landmark Hazard / R.O.W. Remove Hazard / R.O.W. Remove 2.ii. 1.v. R.O.W. R.O.W. Remove Remove Hazard/ R.O.W._ Remove 1.v. Remove 2A. Remove Hazard Remove R.O.W. Remove 2.iii. R.O.W. Remove 2.iii. R.O.W. Remove 2.iii. R.O.W. Remove 2.iii. R.O.W. Remove 2.ii. R.O.W. Remove 2.ii. R.O.W. Remove 2.ii. R.O.W. Remove 2A. R.O.W. Remove 1.v. R.O.W. Remove l.v. Remove 2.ii. Remove 1.v. Remove 1.i. Landmark Remove 2.ii Remove l.i. Landmark Remove 1. i. Landmark R.O.W. Remove 1.v. R.O.W. Remove 2.ii Remove 2.ii Hazard / R.O.W. Remove 2.ii Remove 2.ii Remove 2.ii Remove 1.v. Remove Hazard Remove 2.ii. Remove 2.ii. Hazard Remove Hazard Remove 1.v. 2.ii Hazard Hazard Remove Hazard Remove Hazard Remove Hazard Remove NOTES: 1. NO CRITICAL AREAS OR BUFFERS EXIST ON THE SITE. 2. PROPERTY LINE IS THE CLEARING EXTENT. ALL VEGETATION WITHIN PROPERTY LINE TO BE REMOVED. 3. NO SITE IMPACTS DUE TO TREE REMOVAL ARE ANTICIPATED. 4. SEE L100 LANDSCAPE PLAN FOR LOCATION, TYPE AND SIZE OF REPLACEMENT TREES PROPOSED TO MITIGATE TREE REMOVAL. M = MULTI -STEM (CALIPER = LARGEST TRUNK PLUS SQUARE ROOT OF SUM OF ALL OTHER TRUNKS SQUARED (CITY OF SEATTLE METHODOLOGY) ** = CALIPER MEASURED BY LANDSCAPE ARCHITECT. ALL OTHER CALIPER MEASUREMENTS FROM SURVEY BY OTHERS. LEGEND < 7N a EXISTING TREE posse a In lcatlons of disease I I Hazard I Remove 1 REVISED PER HEARING EXAMINER CONDITIONS OF APPROVAL GM 7-14-17 architecture 4 2 — LANDSCAPEREVIEWAND PRICING - GM 79� 17 suRveED: scA_e planning VERTICAL: NAVD 1988 !y landscape architecture [�REVISED PER CITY COMMENTS 8 16-17 --- , » HORIZONTAL: NAD 1983/1991 urba n design 8-16 �9-21-17 DESIGNED: __ 20— 0geospatial analysis 4 REVISED PER CITY COMMENTS GM REVISED PER CITY COMMENTS DRAW"COTTAGES 1925 Post Alley, Suite 36 wSTAFEJGrr5 GM 3-17 GM a-f Seattle, WA 98101 ,AN R,APE�A MREC� 6 REVISED PER CITY COMMENTS GM 12-15-17 CHECKED: I ONE iNc" DATUM Renton F NOUONECNCH Phone 206.650.8589 7 REVISED PER CITY COMMENTS SCP 02-05-18 CO - SCALE ACCORDINGLY www.eimplan.com/seattle 4 f °� �0°` -- -- APrRovED: "" "' 972 NO. REVISION �y DATE APPR __— TREE NUMBER (SEE INVENTORY LIST) TREE TO BE REMOVED TREE TO REMAIN R=3 96224 20 40 :M CITY OF It (D RENTON Planning/Building/Public Works Deo- I SIGNIFICANT TREE PRIORITIZATION Priority One I. Landmark trees; ii. Significant trees that form a continuous canopy; iii. Significant trees on slopes greater than twenty percent (20%); iv. Significant trees adjacent to critical areas and their associated buffers; and v. Significant trees over sixty feet (60') in height or greater than eighteen inches (18") caliper. Priority Two i. Healthy tree groupings whose associated undergrowth can be preserved; ii. Other significant native evergreen or deciduous trees; and iii. Other significant non-native trees. Priority Three Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. RMC 4-4-130 iN COMPLIANCE WITH CITY OF i EVCIN SIANDARD RENTON SPECIAL CARE COMMUMITY, LLC RENTON SPECIAL CARE COMMUMI TY 17033108TH AVE SE, RENTON, WA 98055 TREE INVENTORY & PROTECTION PLAN U Q J ■ LV cc v rQ V LQ ;Al'_ _L 30OOK - �AGr: ------ - O :RAW'.NG N0. E-000 Lai s #4 # z z z z z z z Q Q Q W Q U J _Q U W CL z 0 F-- z W rr 3 _U C N C1 U U in 0 J O 0 Q) .0 0 0 Q U N O 0 0 cD 1n to i d C 0 0 NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 29, RGE 5 E, KING COUNTY, WASH/NGTON INTERIOR PARKI - 26 PARKING 390 SF OF AND 945 SF - 26 PARKING AND PROVIDE - 1 SHRUB PE AND PROVIE - GROUNDCOVE WITHIN 3 YE/ NO MORE TH AND AN INTE PROPOSED 7' T, RETAINING WALL 6' TALL WOOD F 10' FULLY SIGHT BARRIER BETWEE AND LESS INTEN LANDSCAPE AND 3'H X 5' WIDE I ON WOOD POST`, NOTES: 1. SEE SHEET L200 FOR PLANT DETAILS AND SCHEDULE. 2. ALL TREES TO BE A MINIMUM OF 2" CALIPER AT 54" ABOVE GRADE. 3. STREET TREES TO BE FROM THE CITY OF RENTON APPROVED TREE LIST. 4. LOOSEN SUBGRADE BY RIPPING AND RECOMPACTING, AND INSTALL 6" DEEP TOPSOIL IN ALL PLANT BEDS AND LAWN AREAS. 5. ALL EXPOSED SOIL AREAS IN PLANT BEDS TO RECEIVE A 3" THICK LAYER OF SHREDDED BARK MULCH. 6. HYDROSEED TURF GRASS SEED TO CREATE LAWN IN ALL AREAS NOT OTHERWISE INDICATED AT PAVEMENT OR PLANT BED. PROTECT PLANT BEDS AND PAVEMENT FROM HYDROSEED OVERSPRAY. A / j -47j e COTTAGES "'./ Renton A LNWLx 41M0e1 (wet Cirta��v.rt planning architecture Chi landscape architecture urban design geospateal analysis 1925 Post Alley, Suite 313 STATE 'IF Seattle, WA 98101 acwsTeaeo W"S-NCTON �A�CAP[ AR�NIT[�T Phone 206.650.8589 /._. www.elmplan.com/seattle '"'�>t1 10 \_SE 172ND ST STREET TREES REQUIRED AND PROVIDED 10' LANDSCAPE CONSISTING OF TREES, SHRUBS AND GROUNDCOVER (INCLUDING LAWN) ALONG PUBLIC STREET EXCLUDING AREA OF DRIVES AND WALKS. FILL PLANTER POTS WITH 1" LAYER OF DRAINAGE AGGREGATE, FILTER FABRIC AND PLANTING SOIL. CONTRACTOR TO MAINTAIN PLANTS IN A HEALTHY CONDITION UNTIL FINAL ACCEPTANCE. EXISTING TREES TO REMAIN SHALL BE PROTECTED THROUGHOUT CONSTRUCTION WITH 4' CONSTRUCTION FENCE AT DRIPLINE. ALL PLANTS WILL BE WATERED BY IRRIGATION. N 1 2 REVISED PER HEARING EXAMINER CONDITIONS OF APPROVAL LANDSCAPE REVIEW AND PRICING REVISED PER CITY t COMMENTS 8-16-17 REVISED PER CITY COMMENTS _ REVISED PER CITY COMMENTS GM 7-14-17 GM 7-19-17 3 - GM 9-6-17 4 GM 9-21-17 5 GM GM 11-13-17 12-15-17 REVISED PER CITY COMMENTS REVISED PER CITY COMMENTS REVISION SCP 02-05-18 NO. BY DATE APPR SURVEYED: DESIGNED: GM DRAWN: GM CHECKED: GO APPROVED: SCALE: 1 "=20'—O" ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY x VERTIGL: Now 1988 HORIZONTAL: NAD 1483/1W DATU M 20 40 :1 CITY OF RENTON Planning/3uilding/Public Works Dept. 6' TALL WOOD FENCE 10' WIDE FULLY SIGHT -OBSCURING LANDSCAPE VISUAL BARRIER LANDSCAPE AND FENCE 10' WIDE PARKING LOT PERIMETER PLANTING - ONE TREE PER 30 LINEAL FEET OF STREET FRONTAGE - ONE SHRUB PER 20 S.F. OF LANDSCAPED AREA (MAX 50% DECIDUOUS) - GROUNDCOVER - STREET TREES REQUIRED AND PROVIDED - 10' WIDE LANDSCAPE CONSISTING OF TREES, SHRUBS AND GROUNDCOVER (INCLUDING LAWN) ALONG PUBLIC STREET EXCLUDING AREA OF DRIVES AND WALKS. R=396225 I IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON SPECIAL CARE COMMUMITY, L L C RENTON SPECIAL CARE COMMUMITY 17033108TH AVE 5E, RENTON, WA 98055 LANDSCAPE PLAN 05-17-201 FIELDDDOK: PAGE: DRAWING 10. L-100 S-ffl: # #0# # U Q J W �C U v Q v W cc NE 114 OF THE SW 114 AND SE 114 OF THE NW 1/4, SEC 29, TWN 29, RGE 5 E. KING COUNTY, WASHINGTON '510 0 E ICI- n Ln O 40 0 0 a NOTES: 1. SEE SHEET L200 FOR PLANT DETAILS AND SCHEDULE. IEEM _1�1c COTTAGES "d Renton { I:��yc,t MFMU�I iAXt Cuuwi+t:n N o 1 REVISED PER HEARING EXAMINER CONDITIONS OF APPROVAL Um /-14-1 I 1988 planning ct 2 LANDSCAPE REVIEW AND PRICING GM 7-19-17 --_SCALE._10'-0"HORIZON`!'"- NAVD 83/1architecturej�.. -- 3 -__ AL: NAD 1983/1991 landscape architecture REVISED PER CITY COMMENTS 8-16-17 GM 9-6-17 Dman:<GM urban design 4 REVISED PER CITY COMMENTS GM 9-21-17 geospatial analysis- 1925 Post Alley, Suite 3B�;Qy c5 REVISED PER CITY COMMENTS GM 11-13-17 GM ONE INCH DATU M Seattle, WA 98101 FULL "f,�tE�REc.rEc V REVISED PER CITY COMMENTS GM 12-15-17 CHECKED: CO IF NOT ONE INCH Phone 206.650.8589 - 7 REVISED PER CITY COMMENTS SCP 02-05-18 APPROVED: SCALE ACCORDINGLY www.elmplan.com/seattle A° nx ,�° ;";°" NO. REVISION BY DATE APPR --- 10 20 40 CITY OF '� RENTON Planning/Building/Public Works Dept. O LAWN I I �O I U Q J iN COMPLIANCE WITH CITY OF RENTON STANDARDS I RENTON SPECIAL CARE COMMUMITY, L L C RENTON SPECIAL CARE COMMUMITY 17033108TH AVE SE, RENTON, WA 98055 LANDSCAPE PLAN ENLARGEMENT LQ cc W DATE: CL 05-17-201 `) PAGE: DRAWING NO: L-101 z SHEET. # #W # z PLANT SCHEDULE z DECIDUOUS TREES Z Z Z Q ' Q • Q % � W • Q U J Q U W z O I— Z. W cc EVERGREEN TREES :_ 0 N L6 0 LL Y_ O 0- 3 0 0 a O U "1 0 J 0 0 N J / a� L (/7 / 0 Q U N 0 / U U c 0 c a) ry cD cD .3 0 BOTANICAL NAME / COMMON NAME Acer circinatum 'Pacific Fire' / Compact Vine Maple Acer palmatum var. dissectum'Virdis' / Virdis Japanese Maple Acer palmatum 'Osakazuki' / Osakazuki Japanese Maple Acer saccharum / Sugar Maple Amelanchier alnifolia / Serviceberry Amelanchier laevis 'Lustre' / Lustre Allegheny Servicebery Betula utilis jacquemontii / Whitebarked Himalayan Birch Cercidiphyllum japonicum / Katsura Tree Comus florida rubra / Pink Flowering Dogwood Comus nuttallii / Western Flowering Dogwood Gleditsia triacanthos inermis 'Shademaster' TM / Shademaster Locust Oxydendrum arboreum / Sourwood Tree Prunus serrulata 'Amanogawa' / Japanese Flowering Cherry Pyrus calleryana 'Cleveland Select' / Cleveland Select Pear Quercus ganyana / Oregon Oak BOTANICAL NAME / COMMON NAME • Cedrus allantica 'Glauca Fastiga' / Atlas Cedar SHRUBS BOTANICAL NAME / COMMON NAME • Ceanothus x 'Blue Sapphire' / Blue Sapphire Ceanothus Choisya temata / Mexican Orange ,I • Hydrangea quercifolia 'Munchkin' / Oakleaf Hydrangea • Hydrangea quercdolia 'Pee Wee' / Oakleaf Hydrangea • j Philadelphus x virginalis / Mock Orange • Philadelphus x virginalis 'Dwarf Snowflake' / Dwarf Snowflake Mockorange Rhododendron x 'Cunningham's White' / Cunningham's White Rhododendron • Sarcococca hookeriana humilis / Sweet Box O Spiraea betulifolia lucida / Shiny Leaf Spirea • ; Sydnga meyed 'Palibin' I Dwarf Korean Lilac Vaccinium ovatum I Evergreen Huckleberry • Viburnum x burkwoodii / Burkwood Viburnum HERBACEOUS PERRENIALS BOTANICAL NAME / COMMON NAME • Astilbe x arendsii 'Amethyst' / Amethyst Astilbe • Athyrium nipponicum 'Pictum' / Japanese Painted Fern NE 114 OF THE SW 114 AND SE 114 OF THE NW 1/4, SEC 29, TWN 29, RGE 5 E, KING COUNTY, WASHINGTON SIZE CAUHT qTY � , 1. NOTES: DIG PLANTING PITS DOWN AND OUTWARD SO THAT 15 gal 5' 6 `, i WATER WILL NOT COLLECT DIRECTLY BELOW ROOTBALL. f r ` / �` 2. SOAK PLANTING PIT PRIOR 5 gal 3' H 2 CENTRAL LEADER. TO PLANTING DO NOT CUT. DO NOT �r /� 3. SPRAY SOIL OFF OF 45 3" Cal Single PRUNE WITHOUT APPROVAL /� ROOTBALL gal stem 1 FROM L.A. 4. UNCOIL TWISTED OR i 12 GA. BAILING WIRE WITH - CIRCLING ROOTS PRIOR 20gal. 2"Cal 1 BLACK RUBBER HOSE TO - TO PLANTING. CUT OFF ANY PROTECT BARK. FASTEN -._ PERMANENTLY KINKED ROOTS SECURELY BUT LEAVE ROOM -- 5. REMOVE ANY AND ALL 15gal 6' 4 FOR FLEXING OFF OF ROOTBALL PRIORPLASTI TO PLANTINGC N - 25 gal 2.5"Cal 8 TREE TO BE 2-3" ABOVE - - -- - 2X2X8' LONG FIR LEVEL OF EXT'G GRADE _ STAKES. PRESERVATIVE 25 gal 2.5"Cal 32 3-4" HIGH SOIL SAUCER. TREATED WITH WOODLIFE w OR EQ. PRESTAIN DARK REMOVE PRIOR TO FIRST BROWN. USE 3 STAKES � WINTER RAINY SEASON FOR TREES WITH 2-112" `— 30 gal 2"Cal 2 FINISH GRADE —- CALIPER OR GREATER 25 gal 2.5"Cal 25 gal 2.5"Cal 7 45 gal 3" 1 B 8L B 2.5"Cal 4 30 gal 3"Cal 2 20 gal. 2"Cal 2 25 gal 2.5"Cal 7 SIZE CAUHT Ql 25 gal 8' 17 SIZE Ql 5 gal 77 5 gal 26 5 gal 2 5 gal 18 5 gal 69 112 11 48 111 2 203 11 QTY 68 10 REMOVE ALL WRAPPINGS FROM TOP HALF OF ROOTBALL ---- - ---- ROUGHEN SIDES OF TREE PIT BACKFILL SOIL FROM PIT EXCAVATION z PEDESTAL OF EXT'G SOIL. - TAMP THOROUGHLY WITH FOOT ONLY TWO TIMES ROOTBALL DIA. TREE PLANTING, TYP. SCALE: NTS GROUND COVERS Carex oshimensis'Everest' / Everest Japanese Sedge 1 gal Helictotrichon sempervirens 'Saphirsprudel' / Saphire Fountain Blue Oat Grass 1 gal Hemerocallis x 'Joan Senior' / Daylily 1 gal Hemerocallis x 'Wild Horses' / Adorable Tiger Daylily 1 gal Heuchera americana 'Green Spice' / American Alumroot 1 gal Hosta sieboldiana 'Elegans' / Sieboldiana Elegans Hosta 1 gal Iris tenax / Oregon Iris 1 gal Lavandula angustifolia / English Lavender 1 gal Liriope muscari / Lily Turf 1 gal Miscanthus sinensis 'Little Miss' / Little Miss Maiden Grass 1 gal Pennisetum orientale / Oriental Fountain Grass 1 gal Phlox subulata / Moss Phlox 4" pot Rudbeckia fulgida / Coneflower 1 gal BOTANICAL NAME / COMMON NAME SIZE Ajuga reptans / Carpet Bugle flat Erica camea 'Ruby Glow' / Ruby Glow Heather Erica camea 'Winter Beauty' / Winter Beauty Pink Heath 1 REVISED PER HEARING EXAMINER C01 rch n architecture 2 LANDSCAPE REVIEW AND PRICING a�id((t{� landscape architecture ��/[Q 3 REVISED PER CITY COMMENTS 8-16-17 AWe urban design - — — - - -- --- — gevspatiaf ans" 4 REVISED PER CITY COMMENTS COTTAGES 1925 Post Alley, Suite 313 STATE OF 5 REVISED PER CITY COMMENTS WASH NGTON di Seattle, WA 98101 AN ; TERED T 6 REVISED PER CITY COMMENTS Renton A IiRpLLT AtEraeY CN" Carrunm Phone 206.650.8589 7 REVISED PER CITY COMMENTS C,nRI$iQPfIrR 1. �T/[R�Rf www.eimplan.com/seattle T=R "MR NO REVISION 1 gal 1 gal OF APPROVAL GM 7-14-17 7-19-17 SURVEYED: (GSM 9-6-17 DESIGNED: GM -_GM _ GM 9-21-17 .-. -- ----- GM 11-13-17 MN: GM 12-15-17 CHECKED:RGM co SCP 02-05-18 BY DATE APPR APPROVED: t 2 \ MI II TI—'.z�TFM TRFF PI ANTIN(, TYP SCAL N-S BIKE RACK SCALE: 1 "=1'-0" SCALE: 1 "=10'-0" ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL NAD 1983/1991 DATU M 12 GA. BAILING WIRE WITH BLACK RUBBER HOSE TO PROTECT BARK. FASTEN SECURELY BUT LEAVE ROOM FOR FLEXING 2X2X8' LONG FIR STAKES. PRESERVATIVE TREATED WITH WOODLIFE OR EQ. PRESTAIN DARK BROWN. PLACE ON SIDE OF PREVAILING WIND SET PLANT 2-3" ABOVE FINISH GRADE 2" BARK MULCH. FEATHER TO TREE TRUNK FINISH GRADE REMOVE ALL WRAPPINGS `1111 FROM TOP HALF OF ROOTBALL BACKFILL SOIL FROM PIT EXCAVATION PEDESTAL OF EXT'G SOIL. TAMP THOROUGHLY WITH FOOT ONLY 3 FIR '!iap TWO TIMES ROOTBALL DIA. U SET PLANT 2-3" ABOVE FINISH GRADE BACKFILL WITH SOIL FROM PIT EXCAVATION 2" BARK MULCH 3-4 HIGH SOIL SAUCER. REMOVE PRIOR TO FIRST WINTER RAINY SEASON FINISH GRADE REMOVE ALL WRAPPINGS Q FROM TOP HALF OF ROOTBALL J LIMIT OF BARE ROOT SPREAD PEDESTAL OF EXT'G SOIL. TAMP THOROUGHLY WITH FOOT ONLY SCARIFY SIDES OF PLANTING PIT SCALE:— NTS - - - -- -- -- SET PLANT AT NEW ° FINISH GRADE ° BARK MULCH, 3" DEPTH, FEATHER TO BASE OF 0 PLANT 'Ono oo FINISH GRADE - — - - CONTROLLED RELEASE FERTILIZER GRANULES, PLACE PRIOR TO BARK MULCH APPLICATION -- BACKFILL WITH SOIL FROM PIT EXCAVATION NOTES 1. BIKE RACK TO HAVE PLASTISOL FINISH 2. ALL MOUNTING HARDWARE TO BE STAINLESS STEEL ). STEEL TUBE BIKE RACK TE SLAB LANGE PLATE NUT W. THREADLOCK ASHER BOLT (3) aim CITY OF RENTON Planning/Building/Public Works Dept. R=396227%­1_._.! N COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON SPECIAL CARE COMMUMITY, L L C RENTON SPECIAL CARE COMMUMI TY 17033108TH A VE SE, RENTON, WA 98055 LANDSCAPE DETAILS LW cc V DATE: 05-17-201 (J) FIELD800K: PAGE: O DRAWING NO: L-200 z SHEET: LLj # #0� U Q J W I z z Z z z z z Q Q Q Uj Q U J _Q U W z 0 H z w e FROM SOURCE 2" IRRIGATION SERVICE LINE 2" IRRIGATION DEDUCT METER IF NECESSARY 1" QUICK COUPLING VALVE MAINLINE BY-PASS MASTER VALVE BOX MASTER VALVE 2" SCHEDULE 40 PVC MAINLINE 1 P.O.C. SCHEMATIC / SCALE: N.T.S. MASTER CONTROL VALVE -MAINLINE SIZE PVC MAINLINE 6" DEPTH 5/8" GRAVEL BRICK SUPPORT AS REQUIRED MASTER VALVE SCALE: N.T.S. STATE APPROVED BACKFLOW — ASSEMBLY, FEBCO 85OU OR EQUIVALENT APPROVED BY AUTHORITY HAVING JURISDICTION 00 ��- 2, IN I c 7 U 12" BRASS PIPE AND FITTINGS BOTH SIDES OF ASSEMBLY 1 NOTE: ° INSPECTION OF COMPLETED ASSEMBLY o FROM SOURCE BY CERTIFIED TESTER REQUIRED. c 6 6 BACKFLOW PREVENTOR SCALE: N.T.S. c c BRASS NIPPLE 12" MIN LENGTH BRASS NIPPLE 3" MIN LENGTH QUICK COUPLER VALVE SCALE: N.T.S. UTANUULAR VALVE BOX / EXTENSIONS AS REQ'D DISH GRADE LV NIPPLE C FEMALE ADAPTER PVC MAINLINE IN NE 114 OF THE SW 114 AND SE 114 OF THE NW 1141 SEC 29, TWN 29, RGE S E, KING COUNTY, WASH/NGTON Uj 0 00 V, FINISH GRADE QUICK COUPLER VALVE BRASS NIPPLE 3" MIN LENGTH BRASS 90 ELL RUBBER VALVE MARKER MAINLINE 16" MIN GALV NIPPLE 3/4" STREET �T ELL 5/8" GRAVEL SUMP MANUAL DRAIN VALVE SCALE: N.T.S. VALVE BOX LID MARKED "CONTROL VALVE" AUTOMATIC VALVE SCH. 80 PVC 90 DEG ELL SCH. 80 PVC �o NIPPLE PVC MAINLINE TEE (BUSH AS 6" MIN. DEPTH 5/8" REQ'D) WASHED GRAVEL *VALVE INLET SIZE TO MATCH OUTLET PIPE SIZE. REMOTE CONTROL VALVE JLAU:: N.T.S. rY`LM� LAWN OR 6" POP UP SCALE: N.T.S. INISH GRADE OP -UP SPRINKLER S SPECIFIED 12" MARLEX STREET ELL 0 DEG BARBED ELL 12" SWING PIPE D DEG BARBED ELL VC TEE FINISH GRADE 11- 2" CLASS 160 PVC SLEEVE —I1 3/4" ANGLE VALVE C FINISH GRADE w O U (V PVC LATERAL PVC MALE ADAPTER PLASTIC VALVE BOX 90 DEG BARBED ELL -- NOTES: - INSTALL POP-UP 4" FROM ALL HARDSCAPE SURFACES. - USE BOTTOM INLET ONLY. HI -POP SPRINKLER SCALE: N.T.S. III—III—IIIIIIIIIII I -III -I I - FINISH -III-I (I_I GRADE POP-UP SPRINKLER — II -- I PVC LATERAL LINE --- LATERAL LINE FITTING 90 DEG BARBED ELL 1/2" PE SWING PIPE -� `12" MIN LENGTH 1 REVISED PER HEARING EXAMINER CONDITIONS OF APPROVAL GM7P77 planning LANDSCAPE REVIEW AND architecture �1�((� d 2 GM__--- SDRVEYED: S�.A�E: landscape architecture ��/Q 3 REVISED PER CITY COMMENTS &16-17urban design GM���Beospatialanalysis 4 REVISED PER CITY COMMENTS oESICNED: GM20'—O" CAGES GM 1925 Post Alley, Suite 36 STATE o 5 REVISED PER CITY COMMENTS GM 11-13-17 DRAW GM wwS+S E-EID ONE INCH Seattle, WA 98101 °EGS'E"ro REVISED_ GM 12-15-17 CHEG(m: �c� �� e.� AA��•ac. 6 PER CITY COMMENTS Renton Phone 206.650.8589 7 REVISED PER CITY COMMENTS — Cp AT FULL SCALE n nwu�-c Wvo.. u.. ewe"uu.in SCP 02 AC 1 O IF NOT ONE INCH vvwW.elmplan.com/seattle "R�c� ;�`,�a ; NO -- L-VJ- V �p�p SCALE ACCORDINGLY REVISION BY DATE APPR ___ IRRIGATION ZONE SCHEDULE IRRIGATION NOTES ZONE DESCRIPTION OF PLANTING 1. INSTALL IRRIGATIION SYSTEM IN ACCORDANCE WITH ALL LOCAL LOCAL CODES AND REGULATIONS. 1 TREES, SHRUBS AND PERENNIALS 2. IRRIGATION PLANS ARE DIAGRMAMMATIC. ALL IRRIGATION EQUIPMENT SHALL 2 TREES, SHRUBS AND PERENNIALS BE PLACED IN PLANTED AREAS WHENEVER POSSIBLE. FIELD ADJUST LINES TO AVOID CONFLICT WITH UTILITIES AND EXISTING CONDITIONS. 3 TREES, SHRUBS AND PERENNIALS 3. SYSTEM IS DESIGNED TOP OPERATE WITH STATIC PRESSURE BETWEEN 40 AND 4 TREES, SHRUBS AND PERENNIALS 60 PSI WITH A MINIMUM 70 GPM AT POINT OF CONNECTION. 5 TREES, SHRUBS AND PERENNIALS 4. ZONES ARE BASED ON THE SITE PLAN / DATA AVAILABLE. CONTRACTOR SHALL VERIFY GPM AND PSI AT POINT OF CONNECTION PRIOR TO STARTING WORK. 6 ! TURF NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF ACTUAL FIELD DATA DIFFERS FROM THIS INFORMATION. 7 TURF 5. CONTRACTOR SHALL FIELD MARK LAYOUT OF TRENCHES AND VALVE 8 TURF I LOCATIONS FOR REVIEW BY LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. 9 TREES, SHRUBS AND PERENNIALS 6. PROVIDE 12" POP-UP SPRINKLER HEADS FOR ALL SHRUB PLANTING BEDS UNLESS OTHERWISE INDICATED ON PLANS. 10 TREES, SHRUBS AND PERENNIALS 7. EXCEPT WHERE SLEEVES ARE SHOWN, MAINLINE IS SHOWN BENEATH PAVING 11 TREES, SHRUBS AND PERENNIALS SURFACES FOR GRAPHIC CLARITY ONLY. ACTUAL LOCATION SHOULD BE IN PLANTING AREAS. 12 TREES, SHRUBS AND PERENNIALS 8. LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR ALL SLEEVING UNDER ALL 13 TURF HARDSCAPE SURFACES. CONTRACTOR SHALL VERIFY WITH LANDSCAPE ARCHITECT ALL SLEEVE LOCATIONS, QUANTITIES AND SIZES TO ACCOMMODATE 14 TURF AND TREES ALL IRRIGATION PIPING. 15 SHRUBS 9. CONTRACTOR SHALL COORDINATE IRRIGATION POINT OF CONNECTION AND LOCATION OF AUTOMATIC CONTROLLER. COORDINATE ALL WITH OTHER TRADES 16 TURF AND TREES INVOLVED. 17 TURF AND TREES 10. ALL COMPONENTS OF IRRIGATION SYSTEM SHALL BE INSTALLED AND ADJUSTED TO PROVIDE ADEQUATE COVERAGE AND MINIMIZE OVERSPRAY ONTO 18 TREES, SHRUBS AND PERENNIALS BUILDINGS, WALKWAYS, OR ROADS. 19 TREES, SHRUBS AND PERENNIALS 11. ALL VALVES SHALL BE LOCATED IN A MANNER THAT FACILITATES ACCESS FOR MAINTENANCE. SIZE BOXES TO ACCOMODATE COMPLETE VALVE ASSEMBLY PER 20 TURF DETAILS. MAINTAIN 18" BETWEEN VALVE BOXES AND ADJACENT VALVE BOXES AND/OR PAVEMENT. 21 TURF 12. ALL VALVE BOX COVERS SHALL BE BLACK. 22 TREES, SHRUBS AND PERENNIALS 13. INSTALL VALVE BOXES PERPENDICULAR TO WALKS, CURBS, AND/OR WALLS. 23 TREES, SHRUBS AND PERENNIALS 14. INSTALL TWO (2) CONTROL VALVES IN ONE (1) VALVE BOX WHEREVER 24 TURF AND TREES POSSIBLE. 25 TURF AND TREES 15. INSTALL QUICK COUPLER VALVES AND CONTROL VALVE IN ONE (1) VALVE BOX WHENEVER POSSIBLE. 26 SHRUBS 16. INSTALL'JUMBO' BOX WHEN TWO CONTROL VALVES ARE ADJACENT TO QUICK 27 TURF AND TREES COUPLING VALVE. 28 TREES, SHRUBS AND PERENNIALS 17. INSTALL IRRIGATION HEADS: A. PERPENDICULAR TO SLOPE OR FINISHED GRADES. 29 j TURF B. FLUSH WITH ALL WALKS AND CURBS. C. 1" MIN. FROM ALL WALKS AND WALLS. 30 TREES, SHRUBS AND PERENNIALS 18. CONTRACTOR SHALL PROVIDE, INSTALL AND MAKE POWER CONNECTIONS TO 31 TREES, SHRUBS AND PERENNIALS CONTROLLER TO ALLOW FOR COMPLETE WORKING SYSTEM. 32 TREES, SHRUBS AND PERENNIALS 19. A WATER WINDOW TIME (12:10AM - 5:OOAM) WILL BE REQUIRED TO PROVIDE FOR ADEQUATE SOIL IRRIGATION DURING PEAK SUMMER TIME DEMAND. 33 TURF CONTRACTOR DESIGN BUILD RESPONSIBILITIES 34 TREES, SHRUBS AND PERENNIALS CONDITIONS OF USE: CONTRACTOR IS REPONSIBLE FOR SUPPLYING THE LANDSCAPE ARCHITECT WITH SHOP DRAWINGS AND PRESSURE LOSS CALCULATIONS FOR THE IRRIGATION SYSTEM PRIOR TO THE INSTALLATION OF THE IRRIGATION EQUIPMENT. THE CONTRACTOR WILL BE RESPONSIBLE TO ENSURE THAT PRESSURE TO THE HEADS IS SUFFICIENT IN ALL ZONES AND THAT THE IRRIGATION SYSTEM IS WORKING PROPERLY. SEE ARCHITECTURE AND CIVIL/MECHANICAL DRAWINGS FOR THE LOCATION OF THE CONTROLLER (ADMIN BUILDING MECHANICAL ROOM). VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1%1 DATUM R=396229 CITY OF RENTON Planning/Building/Public Works Dept. IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON SPECIAL CARE COMMUMITY, LLC RENTON SPECIAL CARE COMMUMI TY 17033108TH AVE SE, RENTON, WA 98055 IRR/GA TION DETAILS U a J 0- LQ V DATE: 05-1 7 201 FIELDBOOK PAGE O DRAWING NO: ~ SHEE L-301?: 0 ### # QC