CITY OF RENTON
EROSION AND SEDIMENT CONTROL NOTES
1. CLEARING LIMITS:
A. PRIOR TO ANY SITE CLEARING OR GRADING, AREAS TO REMAIN
UNDISTURBED DURING PROJECT CONSTRUCTION SHALL BE
DELINEATED. AT A MINIMUM, CLEARING LIMIT DELINEATION
FLAGGING SHALL BE PROVIDED AT THE EDGES OF ALL
SENSITIVE AREA BUFFERS.
2. KEEP THE GROUND COVERED -
A. MINIMIZE THE AMOUNT OF EXISTING VEGETATION THAT YOU
MUST DISTURB FOR CONSTRUCTION. KEEP OFF SENSITIVE AREAS
AND THEIR BUFFERS.
B. ALL DISTURBED AREAS SHALL BE COVERED AND/OR MULCHED
WITHIN 12 HOURS, IF THEY ARE TO REMAIN UNWORKED FOR
MORE THAN 7 DAYS FROM MAY 1ST TO SEPTEMBER 30TH.
DURING THE MONTHS OF OCTOBER 1ST THROUGH APRIL 30TH,
DISTURBED AREAS MUST BE COVERED OR MULCHED IF LEFT
UNWORKED WITHIN 2 DAYS
C. ACCEPTED MULCH MATERIAL INCLUDES STRAW, WOOD FIBER AND
CELLULOSE.
D. AREAS NOT BEING WORKED FOR 30 DAYS OR MORE SHALL BE
VEGETATED, UNLESS THE CITY DETERMINES THAT WINTER
WEATHER MAKES VEGETATION ESTABLISHMENT INFEASIBLE. IF
THIS IS THE CASE, IT MUST STILL BE MORE PERMANENTLY
STABILIZED, USING METHODS SUCH AS BONDED FIBER MATRIX
OR OTHER MORE STABLE BMP'S.
E. SLOPES AND STOCKPILES 3H:1V OR STEEPER AND MORE THAN
10 FEET OF VERTICAL RELIEF SHALL BE COVERED IF THEY ARE
UNWORKED FOR MORE THAN 12 HOURS.
F. ALL AREAS NOT BEING WORKED PRIOR TO OCTOBER 1, AND ARE
BEING SEEDED, SHALL BE SEEDED BY SEPTEMBER 23.
MULCHING IS REQUIRED TO PROTECT ALL SEEDED AREAS UNTIL
AN ADEQUATE GROWTH IS ESTABLISHED.
G. AREAS THAT ARE BEING HYDRO SEEDED SHALL HAVE A
TACKIFIER MIXED INTO THE HYDRO SEED TO HELP STABILIZE
MIXTURE ONTO THE SOIL.
H. ENOUGH COVER MATERIAL TO SUFFICIENTLY PROTECT ALL
DISTURBED AREAS SHALL BE STOCKPILED ON THE SITE AT THE
BEGINNING OF THE WET SEASON.
3. DUST CONTROL:
A. DUST IS TO BE CONTROLLED ON THE CONSTRUCTION SITE.
B. WATER TRUCK WILL BE USED TO CONTROL DUST ON DIRT/GRADED
AREAS ONLY.
C. NO SITE RUN OFF IS TO BE GENERATED BY OVER USE OF
WATERING.
D. CONTROLLING DUST ON PAVED ROADWAYS WILL BE DONE BY THE
USE OF A SWEEPER WITH WATER -JET SPRAYERS. NO RUN OFF
FROM SPRAYERS SHALL REACH THE CATCH BASINS.
4. PERIMETER PROTECTION:
A. PERIMETER PROTECTION TO FILTER SEDIMENT FOR SHEETWASH
SHALL BE LOCATED DOWNSLOPE OF ALL DISTURBED AREAS AND
PROPERLY INSTALLED PRIOR TO UPSLOPE GRADING.
B. 50 LINEAR FEET OF SILT FENCE PER ACRE AND THE NECESSARY
STAKES TO HOLD THE FENCE IN PLACE SHALL BE STORED ON
SITE.
(CONTINUED)
EROSION AND SEDIMENT CONTROL NOTES
5. TRAFFIC AREA STABILIZATION:
A. UNSURFACED DRIVEWAY ENTRANCES, ACCESS ROADS AND PARKING
AREAS USED BY CONSTRUCTION TRAFFIC WILL BE STABILIZED
TO MINIMIZE EROSION AND PREVENT TRACKING MUD.
B. STABILIZED CONSTRUCTION ENTRANCES WILL BE INSTALLED AS
THE FIRST STEP OF CLEARING AND GRADING.
C. CONSTRUCTION ENTRANCES WILL BE SET UP SO THAT ALL
TRAFFIC LEAVING A JOB SITE IS REQUIRED TO TRAVEL THE
ENTIRE LENGTH OF ENTRANCE.
D. ROADS AND PARKING AREAS WILL BE STABILIZED IMMEDIATELY
AFTER THE INITIAL GRADING.
E. CONSTRUCTION ENTRANCES WILL BE STABILIZED WHEREVER
TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND
TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN
1,000 FEET OF THE SITE.
F. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT WILL BE
REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT
COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED
ON -SITE.
G. IF NON-VACTOR TYPE SWEEPERS ARE USED, THE DEPOSITION OF
THESE SWEEPERS MUST BE REMOVED FROM SIDEWALKS AND
GUTTERS. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE
REMOVED OR STABILIZED ON -SITE.
H. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING STREETS.
6. SEDIMENT RETENTION:
A. SEDIMENT RETENTION IS REQUIRED UNLESS NO OFF -SITE
DISCHARGE IS ANTICIPATED FOR THE SPECIFIED DESIGN FLOW.
B. SEDIMENT RETENTION FACILITIES WILL BE INSTALLED BEFORE
GRADING.
C. IF SEDIMENT RETENTION FACILITIES NEED TO BE REMOVED
FOR GRADING, ADDITIONAL PONDS/TRAPS/SYSTEMS TO
ACCOMMODATE STORAGE CAPACITY NEED TO BE INSTALLED ON
SITE. THIS WILL BE DONE PRIOR TO REMOVAL OF EXISTING
FACILITY.
7. SURFACE WATER CONTROL:
A. SURFACE WATER CONTROLS ARE REQUIRED UNLESS NO OFF -SITE
DISCHARGE IS ANTICIPATED FOR THE SPECIFIED DESIGN FLOW.
8. SENSITIVE AREA RESTRICTIONS:
A. PHASING AND MORE CONSERVATIVE BEST MANAGEMENT PRACTICES
(BMP'S) MUST BE EVALUATED FOR CONSTRUCTION ACTIVITIES
NEAR SURFACE WATERS..
9. MAINTENANCE REQUIREMENTS:
A. LARGE PROJECTS WITHIN SENSITIVE AREAS MAY BE
REQUIRED BY THE CITY TO HAVE A DESIGNATED ESC
SUPERVISOR WHO WILL BE RESPONSIBLE FOR ESC REVIEW,
MAINTENANCE AND COMPLIANCE.
B. ESC WILL BE INSPECTED A MINIMUM OF ONCE A WEEK DURING
THE WET SEASON AND WITHIN 24 HOURS OF SIGNIFICANT
STORMS (.5 INCHES/24 HOUR, OR WHERE RUN-OFF IS
GENERATED).
C. THE ESC SUPERVISOR MUST BE AVAILABLE, 24 HOURS, FOR
RAPID RESPONSE TO ESC PROBLEMS AND EMERGENCIES.
D. A 24-HOUR PHONE NUMBER FOR THE ESC SUPERVISOR WILL BE
POSTED IN A CLEARLY VISIBLE LOCATION ON THE PROJECT
SITE.
ASBUILT TES[ NOTES AND DETAILS
FOR
ALL UlM AT TIFFANY PARK
PTN OF THE W1/2 & SE1/4 OF THE SE1/4 AND PTN OF THE NE1/4, OF THE SW1/4 OF SEC. 21,
TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON KING COUNTY STATE OF WASHINGTON
10. FINAL STABILIZATION: PRIOR TO FINAL CONSTRUCTION APPROVAL,
THE FOLLOWING CONDITIONS MUST BE MET:
A. ALL DISTURBED AREAS OF THE SITE WILL BE VEGETATED OR
OTHERWISE PERMANENTLY STABILIZED;
B. STRUCTURAL MEASURES SUCH AS SILT FENCE, SLOPE DRAINS,
ETC. WILL BE REMOVED FROM SITE;
C. ALL PERMANENT SURFACE WATER FACILITIES INCLUDING CATCH
BASINS, PIPES, ETC. WILL BE CLEANED;
D. ANY OFF -SITE CATCH BASINS THAT REQUIRED PROTECTION WILL
ALSO BE CLEANED; AND
E. IF ONLY THE INFRASTRUCTURE OF THE SITE HAS BEEN
DEVELOPED SUCH AS SHORT PLATS AND SUBDIVISIONS, WITH
BUILDING CONSTRUCTION TO OCCUR UNDER A DIFFERENT
PERMIT, THEN THE SENSITIVE AREA BUFFERS, TRACTS, AND
SETBACKS WILL BE CLEARLY MARKED.
CITY OF RENTON, DEVELOPMENT SERVICES STAFF IS AVAILABLE TO ANSWER
ANY QUESTIONS YOU MAY HAVE ABOUT EROSION AND SEDIMENT CONTROL AND
WET SEASON STABILIZATION MEASURES FOR PERMITTED ACTIVITIES IN THE
CITY OF RENTON. PLEASE CALL 425-430-7300.
TEMPORARY EROSION
CONTROL
SEED MIX
MATERIAL
% WEIGHT
% PURITY
% GERMINATION
CHEWINGS OR RED FESCUE
40
98
90
FESTUCA RUBRA VAR. COMMUTATA OR
FESTUCA RUBRA
ANNUAL OR PERENNIAL RYE
40
98
90
LOLIUM MULTIFLORUM OR LOLIUM PERENNE
REDTOP OR COLONIAL BENTGRASS
10
92
85
AGROSTIS ALBA OR AGROSTIS TENUIS
WHITE DUTCH CLOVER
10
98
90
TRIFOLIUM REPENS
BEST MANAGEMENT PRACTICES (BMP) ALTERNATIVES
MULCH MATEFpAL
OUALIIY
APPLICATION
APPLICATION
DEPTH OF
$
STANDARDS
/VW SF
/ACM
APPLICATION
GRAVEL, SLAG, OR
WASHED, 3/4"-1-1/2'
9 CU YDS
3 INCHES
FOR SHORT SLOPES AND AROUND WOODY PLANTS & ORNAMENTALS
CRUSHED STONE
SIZE
USE WHERE SUBJECT TO FOOT TRAFIC. APPDX. 2000 LBS/CU YD.
AIR DRIED, FREE FROM
75- I OOLBS OR
1-1/2 TO 2-1/2
MINIMUM OF 2 IN
USE WHERE THE MULCHING EFFECT IS TO BE MAINTAINED FOR LESS
HAY OR STRAW
UNWANTED SEEDS &
2-3 BALES
TONS OR 90-120
DEPTH, GREATER ON
THAN 3 MONTHS. ANCHOR BY CRIMPING, COVERING WITH NETTING
COARSE MATERIAL
BALES
STEEP AREAS OR NEAR
SPRAYING WITH TACKIFIER AND/OR KEPT MOIST.
PROTECTED AREAS)
PLASTIC SHEETING
MINIMUM 6-MIL
ANCHOR WITH SANDBAGS OR TIRES ON 10-FOOT GRID IN ALL
THICKNESS
DIRECTIONS. OVERLAP EDGES.
JUTE MAT, WOVEN
N/A
N/A
USE ON STEEP SLOPES GREATER THAN 2:1 IN ADDITION
STRAW BLANKET
TO HYDROSEED OR WOOD FIBER WITH TACKIFIER.
SYNTHETIC FIBER
BLANKET
WOOD FIBER
DYED GREEN SHOULD
25-30 LBS.
1000-1500LBS
IF USED ON CRITICAL AREAS, OR STEEP SLOPES, DOUBLE THE
CELLULOSE (PARTIALLY
NOT CONTAIN GROWTH
NORMAL APPLICATION RATE. APPLY W/HYDROMULCHER. NO
DIGESTED WOOD
INHIBITING FACTORS
TIE -DOWN REQUIRED.
FIBERS)
WOOD FIBER APPLIED
1.25 TONS PER
USE 90 GAL/ACRE TACKIFIER FOR STEEP SLOPES LESS THAN
WITH HYDROSEEDING
ACRE;
2:1; 120 GAL/ACRE FOR STEEPER THAN 2:1
OR ALONE
BARK CHIPS
MIN. OF 2 IN. DEPTH
DO NOT USE ON SLOPES STEEPER THAN 6%
WOOD CHIPS
TREAT WITH 12LBS
INITOGEN
MIN. OF 2 IN. DEPTH
DO NOT USE ON SLOPES STEEPER THAN 15%
(HOG FUEL)
FERTILIZER/TON
HYDROSEED IUSE MIX RECOMMENDED I I I I USE DOT SLOPE MIX FOR STEEP SLOPES.
INSTALL[
S A ROAL
PER CITY
RIVEWAYS SHALL BE PAVED TO THE EDGE
F R-O-W PRIOR TO INSTALLATION OF THE
ONSTRUCTION ENTRANCE TO AVOID
AMAGING OF THE ROADWAY
r IS RECOMMENDED THAT THE
INTRANCE BE CROWNED SO THAT
;UNOFF DRAINS OFF THE PAD
PROVIDE FULL WIDTH OF
NOTES INGRESSIEGRESSAREA
1. CONDITION OF USE
1.1 CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON
PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE.
GRAB TENSILE STREBNGTH (ASTM D4751)
200 PSI MIN.
GRAB TENSILE ELONGATION (ASTM D4632)
30%MAX.
MULLEN BURST STRENGTH (ASTM D3786-80A)
400 PSI MIN.
AOS (ASTM D4751)
20-45 (U.S. STANDARD SIEVE SIZE)
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED
FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY
AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO
PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE, THIS CAN SUBSTANTIALLY
INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT THEN ALTERNATIVE MEASURES TO KEEP THE
STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE
ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH
CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY
SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET,
EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A
SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND
DISCHARGED APPROPRIATELY.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE
INSTALLED TO CONTROL TRAFFIC.
Y o STD. PLAN — 215.10
a► PUBLIC WORKS STABILIZED
DEPARTMENT CONSTRUCTION ENTRANCE
MARCH 2008
2 REVISED PER CITY COMMENT
1 ASBUILT
NO. REVISION
SURVEYED:
BCE
DESIGNED:
BJT
BK '11/20/18
BJT
DRAWN:
RAG
BK
11/2/18
BJT
CHECKED:
RAG
BY
DATE
APPR
APPROVED:
BJT
SCALE:
N.T.S.
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
STEEL FENCE POST 6' HIGH MIN.
NOTE:
1: CLIP FENCE TO GALVANIZED WIRE @ 5 FOOT ON -CENTER SPACING
2. WIRE FENCE TO STEEL FENCE POST
TEMPORARY N.G.P.E. FENCE DETAIL
NOT TO SCALE
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
EOIIIVAI_ENT TO ATTACH FABRIC TO POSTS_
2"x2" BY 14 Ga. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC
z
E
N
6' MAX. MINIMUM Vx4" TRENCH
LBACKFILL TRENCH WITH
POST SPACING MAY BE INCREASED NATIVE SOIL
TO 8' IF WIRE BACKING IS USED
2"x4" WOOD POSTS, STEEL FENCE
POSTS, REBAR, OR EQUIVALENT
NOTES
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
AVAILABLE ON SITE.
30-1D0 SIEVE SIZE (0.60-0.15MM) FOR SI LT FILM
A05 (ASTM D4751)
50-100 SIEV E SIZE (0.30-0.15MM) FOR OTHER FABRICS
WATER PERMITTIVITY (ASTM D491)
0.02 SEC^-1 MINIMUM
GRAB TENSILE STRENCHT (ASTM D4632)
180 LBS. MIN, FOR EXTRA STRENGH FABRIC
100 LBS. MIN. FOR STANDARD STRENGHT FABRIC
GRAB TENSILE ELONGATION (ASTM D4632)
30 % MAX.
ULTRAV IO LATE R ES ISTA NCE(ASTM D4355)
70%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
u*IV)w.
STD. PLAN214.00
PUBLIC WORKS SILT FENCEDEPARTMENT
MARCH 2O08
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
IN RENTON
Planning/Building/Public Works Dept.
CITY OF RENTON
EDEPARTMENT OF PUBLIC WORKS
APPROVED BY
APPROVED BY
APPROVED BY
APPROVED BY
'f' �4 1„4� O ��
FS �� l' S I
S14NA L
111201Z0 1
2
O
UO
LLJ x
� Q
Z LL_
LLJ
a
Q rj N N
000 N �
0
z p� c0 00
N Q I I
Ln Ln
L(7 L(7
00 LLJ
N Z N N
(N
. W
C� U
Z j
z�
ZW
Q N
J J
o_ Q
o~
ZZ
Q Li.l
J m
z
O
Z >
�z
L L.I W
LuI
z(.5
0z
w w
J �
U (N
J 2
Q 0
z
DATE W
DATE V� A`
DATE b�
o coy'5
DATE
TESC NOTES AND DETAILS D i 1 /20/2018
ASBUILT - ALLURA AT TIFFANY PARK FIELD60OK:
PAGE:
MAINVUE WA, LLC DRAWING N0:
1110112TH AVE NE, SUITE 202
BELLEVUE, WA 98004 SHEET: 9 OF:68