HomeMy WebLinkAboutMFP19002323.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP19002323
IVR Number: 19002323
Permit Informaon
Permit Name:Comcast Cable Franchise Permit
Address/Locaon :05/02/2019Application Date:8857670060Parcel Number:400 S 43RD ST
Permit Type:05/03/2019Issue Date:Franchise
Permit Work Class:05/02/2020Expiration Date:Major Utility
Job Number:287257Franchise Type:Cable
Description:Comcast proposes to intercept exiting underground S of P03 and overset CP02 in a joint utility trench with PSE.
Pothole all existing utilities. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
Comcast Cable Communication
Management & Comcast Cable Holding
B: (215) 665-1700Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Scott Nall
SEFNCO Communications Inc
2904 4th Ave NE
Puyallup, WA 98372
B: (877) 385-2903
C: (253) 444-9057
Contractor
Business License Number: 41108Construction Contractor: SEFNCCI850QD
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at
425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the
transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with
the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP19002323RESTORATION PER CITY OF RENTON STANDARDSScott Warlick5/3/2019Justin Johnson5/3/2019
MFP190023239:00am - 3:00pmJustin Johnson5/3/2019
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Job#101111448
400 S 43RD ST, RENTON, WA
5/9/2018
Sheet 1 of 3 Eduard.Volianskiy@pse.com
(425) 4246428
PSE
Traffic Control Supervisor:
Eduard Volianskyi
Card No. 010041
Card Exp. 11/30/2019
Eduard.Volianskyi@pse.com
(425) 4246428
MFP19002323
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Job#101111448
400 S 43RD ST, RENTON, WA
5/9/2018
Sheet 2 of 3 Eduard.Volianskiy@pse.com
(425) 4246428
PSE
Traffic Control Supervisor:
Eduard Volianskyi
Card No. 010041
Card Exp. 11/30/2019
Eduard.Volianskyi@pse.com
(425) 4246428
MFP19002323
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Job#101111448
400 S 43RD ST, RENTON, WA
5/9/2018
Sheet 3 of 3 Eduard.Volianskiy@pse.com
(425) 4246428
PSE
Traffic Control Supervisor:
Eduard Volianskyi
Card No. 010041
Card Exp. 11/30/2019
Eduard.Volianskyi@pse.com
(425) 4246428
MFP19002323
P10
CR01
2-4"
CP01, 2432 PED
4-4"
1-2"-INTERCEPT58', 2-4"165', 1-4"85', 1-4", 1-2"1-2", 10'
65', 1-2"15', 2-4", 1-2"180', 2-4"EXISTING 2"
CP02, 4-4", 1-2"
INTERCEPT EXISTING 4", CIP01
CR02
1-4", 1-2"
CIP01
EXISTING 1730
HAND HOLE
30', 1-2"
COMCAST NOTE-
NOT SURE WHERE EXISTING
1730 IS LOCATED ON THIS PRINT.
IT WAS SUPPOSED TO BE OK
WHEN NEW DRIVE WAS BUILT.
HAD BEEN JUST WEST
AND IN FRONT OF SOUTH
ENTRANCE SIGN
COMCAST NOTE;
NEED TO INTERCEPT EXISTING
UNDERGROUND SOUTH OF P03.
OVERSET CP02
CHH01
135', 3-4"1-2"MFP19002323
MFP19002323