HomeMy WebLinkAboutS-382406EXISTING UTILITY DATA GENERAL NOTES MEASUREMENT TO TOP OF MEASUREMENT TO BOTTOM OF v c� POTHOLE # TYPE OF UTILITY MATERIAL SIZE OF UTILITY UTILITY FROM GROUND UTILITY FROM GROUND NOTES 1. ALL GAS POTHOLE INFORMATION PROVIDED BY PUGET SOUND co ENERGY. Tl COMM PVC 2" 22" 24" JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE El. T2 COMM D.B. 5/8" 40" 41" JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE E2. N T3 COMM PVC (2)1", 2" 19" 23" JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE E4 -E5. CL T4 COMM D.B. 5/8" 35" 36" JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE E8. Cl CN PVC 2" 11.5" 13.5" c/) C2 CTV CONC DUCT 5"x16" 6" 22" C3 N/A N/A N/A N/A N/A UNABLE TO LOCATE. LU El POWER PVC 4" 21" 25" JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE Tl. N E2 POWER PVC (2) 4" 40" 44" JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE T4. E3 POWER PVC, D.B. (2)1/4", (2)1", 2", 3" 35" 47" POSSIBLE ADDITIONAL POWER AND COMM IN JOINT TRENCH. m E4 -E5 POWER PVC (2) 4" 24" 28" JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE T3. E7 POWER PVC (2)1", 2"1 6" 35" 51.5" POSSIBLE COMM LOCATED IN JOINT DUCT BANK. E8 POWER PVC 5/8", (2) 2", (2) 4" 34" 40" JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE T4. Wl WATER STEEL 8" 24" 32" W2 WATER STEEL 66" 38" 104" W3 WATER STEEL 54" 37" 91" W4 WATER STEEL 66" 30" 96" W5 WATER DUCTIL IRON 10" 79" 89" W6 WATER DUCTIL IRON 6" 36" 42" W7 WATER CAST IRON 8" 55" 63" W8 WATER CAST IRON 4" 48" 52" W9 WATER IRON/STEEL 4" 39" 43" W10 N/A N/A N/A N/A N/A UNABLE TO LOCATE. Si SEWER PVC 6" 45" 51" 52 SEWER CLAY 6" 52" 58" S3 SEWER CLAY 6" 54" 60" S4 SEWER CLAY 6" 46" 52" 55 SEWER CONC 8" 146" 152" S6 SEWER CONC 8" 69" 77" 57 SEWER CONC 8" 91" 99" S8 SEWER CLAY 12" 67" 79" G1 GAS STW 8" 41" 49" G2 GAS STW 8" 45" 53" G3 GAS PE 2" 47" 49" G4 GAS PE 4" 37" 41" G5 GAS PE 2" 30" 32" a G6 GAS STEEL CASED 2" 32" 34" G7 GAS STW 2" 34" 36" G8 GAS STW 2" 32" 34" 0 G9 GAS STW 2" 30" 32" G10 GAS STW 2" 36" 38" Gil GAS STW 2" 30" 32" E G12 GAS STW 2" 26" 28" G13 GAS STW 2" 26" 28" G20 GAS STW 2" 24" 26" G21 GAS STW 2" 31" 33" G22 GAS STW 8" 37" 45" E ED G23 GAS STW 8" 27" 35" E e G24 GAS STW 8" 21" 29" G25 N/A N/A N/A N/A N/A UNABLE TO LOCATE. E G26 GAS STW 8" 24" 32" G27 GAS STW 2" 21.5" 23.5" = G28 GAS STW 2" 25" 27" 3 G29 GAS PE 2" 27" 29" G30 GAS PE 2" 31" 33" G31 GAS PE 2" 29" 31" SOFT SURFACE, NO ASPHALT. G32 GAS STW 2" 42" 44" G33 GAS STW 2" 34" 36" G34 GAS STW 2" 46" 48" Al CTV/POWER PVC 211,311 33" 35" GROUNDWATER IN POTHOLE. POSSIBLE ADDITIONAL CONDUITS UNDERNEATH. RECOMMENDED FOR APPROVAL By A2 COMM CONIC DUCT 301140" 22" 32" JOSEPH FARAH A2-1 COMM CONIC DUCT 20'1 27" 48" SURFACE WATER UTILITYENGINEER A3 COM/TV/PWR PVC (2) 2"1 3" 28" 33" JOINT TRENCH COMM/TV/PWR S. at 4A POWER PVC 2" 36" 38" vy W Q of r 11' �¢°°E • As NOTED °"VERTII NAST °" e'"ss' CITY OF RENTON HILL UTILITY REPLACEMENT PROJECT STORM SYSTEM IMPROVEMENTS os/os/zon DESIGNEJE E'E`°"°°" Louis Berger ML RE \TO \ PAGE RAW ABG ONE INC" I °� N a °m R�'cts'rEgE° �w �{�T�V G7 BID SET MSG 05/05/2017 MSG "� IL �`gsrotvnt ���� �"°TE ACOOE"NOL. PlanningBuilding/Public Works Dept. POTHOLE SCHEDULE " VED a PMSG s"EE,: 8 OF 89 w /05/17 520 Pike St, Ste 1005, Seattle, WA 98101 206.453.1043 N0. REVISION BY DATE APPR S W P - 3 8 2 4