Loading...
HomeMy WebLinkAboutS-382416qqt 00 M N rL mi i I- LU LU Q W J J Z O Z LU Er 1009 HIGH AVE S PARCEL: 329470-0275 1005 HIGH AVE S PARCEL: 329470-0270 EAVE SSMH RIM=364.88 COC-357.53 (6-8"CONC N & S) NV CONE (8"GONG E &� hVE, LSCAPE DRIVE m " g QWE - EP _ CV _ HIGH SAVE S - - - M- 1012 HIGH AVE S PARCEL: 329470-0400 EAVE 1006 HIGH AVE S PARCEL: 329470-0392 EXISTING 4" CONC. SIDE SEWER FOR 813 HIGH AVE S EX. 10' SEWER BEND AS NEEDED (TYP.) 10" PVC SPOOL (TYP.) (LENGTH AS NEEDED) NEW 6" PVC SIDE SEWER FOR 813 HIGH AVE S 6" PVC SPOOL (TYP.) (LENGTH AS NEEDED) FERNCO EX. 10" VCP PVC TEE "STRONG -BACK" SEWER MAIN COUPLING EXISTING 4" CLAY 10" X 6" (SIZE AS NEEDED) SIDE SEWER FOR (TYP,) 901 HIGH AVE S APPROXIMATE CONFIGURATION PROPOSED SIDE SEWER SIDE SEWER FOR NEW 6" PVC OF EXISTING DUAL SIDE SEWER RECONNECTION 901 HIGH AVE S 915 HIGH AVE S PARCEL: 329470-0285 907 HIGH AVE S PARCEL: GRASS CB TYPE 1 329470-0280 RIM=362.60 LSCAPE CONC EAVE IE-360.50(12"CONC N) DRIVE - \BOT-360.30 _, b� EAVE _ � GRAVEL CLF - "�- - _ cbNC LSC DR4V€ ; GAS AS GAS F 1P � � GAS G Q 365 S01'2T 8"W 525.15 -�� 901 HIGH AVE S REPLACE BOTH SIDE SEWERS FOUND TACK IN LEAD DOWN PARCEL: (LIMITS AS SHOWN) 1.60' IN MONUMENT IN CASE 329470-0290 I CB TYPE I RIM=362.96 IE=358.96(12"PIPE S) IE=358.86(12"PIPE N) 12"DEC BOT=358.46 14"CON 12"CON LSCAPE L A I L ii �12"CON- o 0 - �- CF i T AS 12 PSD GRASS Sscs MH#17 CV- Z BELOW ASPHALT A ' N:175211.4179 SEWER E:1302933.5712 N 175193.8 CB TYPE E 1302853.0 RIM=353.00 IE=358.80(12"PIPE S) IE-358.70(12"PIPE N) BOT=357.40 \ ''DEC LSCAPE _ D GRASS 2"STW° 1e G(P P HP OH IJcn A UHF'' - J r ,, w GRASS SHP OHP GRASS OHP TS LSCAPE 365 TC p o 4\\ C ONG �."- ,C ,C ,C ,C ,C ,C , ,C ,C , , , LSCAPE RRW RhVE' % SEWER C.O. SEWER C.O. SEWER C.O. LSCAPECB TYPE RIM = N 174925.9 SEWER C.O. STORM C.O. N 175026.0 N 175037.9 ° E=3szs1(s"coNc w) N W) I E 1302948.3 N 174963.16 N 17`1968.12 E 1302952.5 E 1302952.9 BOT-361.96 E 1302948.45 E 1302949.36 SEWER C.0. IE=363,m9(6"CONC E) GRASS EAVE N 174909.4 SEWER C.O. STORM CO, IC S GRASS CB TYPE I RIM=363.94 EAVE ro d� E 1302946.5 N 174914.0 N 174951.89 C W IE=363.14(6"GONG E) o m o E 1302947.5 E 1302948.83 D N) E=353,04(6"GONG E) u o mCID 0 = 0219 IE-362.94(6"CONC S) EAVE BENCHMARK "E" VDx \ _ EAVE EAVE E=362.84(8"GONG N) NORTHERLY TOP BOLT OF FIRE ii= \� 1000 HIGH AVE S BOT=361.79 906 HIGH AVE S HYDRANT AT SOUTHEAST CORNER 0 \ r n D PARCEL: PARCEL: OF S 9TH ST AND HIGH AVE S m 329470-0390 910 HIGH AVE S 329470-0382 NLET ELEVATION=366.44' 0 N PARCEL: 329470-0391 RIM=363.49 CB TYPE I [E-361.39(WATER LEVEL) RIM-363.99 IE-361.84(PIPE N) IE=362.19(8"CONC N) .:.` IE=361.84(PIPE S) IE=362.14(8"CONC E) 80T=361.69� RELOCATE EXISTING SIDE SEWER FOR 900 HIGH AVE S FROM EXISTING MH INTO THE EXISTING SEWER NOTES SEWER MAIN IN S 9TH ST. I 1. RECONNECT ALL AC77VE SIDE SEWERS TO NEW SEWER PER RESPEC77VE DETAILS SHOWN ON SHEET S-14. * ALL SIDE SEWERS ARE SHOWN IN THEIR AS -BUILT LOCATIONS D PL I m m II 0 o w m 0 m _ � C0 cwo ip m; m oom w O m w < M m SEWER C. 0. 30' �-+� N 170 0.7 m m E 1302847.4 w cn cn D I/ 813 HIGH AVE S o; N PARCEL: II -cicCm 329470-0300 Do 0 0 n SAVE w m m o > < o w w GRASS 0 m 8' DEC / EAVE : IqN J p. P4 Ri 12". 2PS N 0 S_� � m 0 I Gs s W GAS LLJ S G N W 65 ASPHAL N MH #16 - UG W Z J �12"PSD wo RAOHP CLF TC S U7 dA CLF Ln 365 0 SEWER C.O. SEWER N 175258.4 N 17529 0 E 1302958.8 E 13029, m o m SDMH o m RIM-364.04 D - 0 IE=360.84(12"CONC E Ln < 0 P1VC EAVE IE-360.74(12"CONC N -1 0 IE=360.64(12"GONG N, T o I OD BOT-359.84 8 /lJ = n: -10, CB TYPE I m C) I -4x RiM-363.49 D yi IE=361.49( 8"GONG S) %D cn -� T 0 m o�y IE-361.49(4"CONC E) om �" IE=361.39(6"GONG N) ai ro IE-36L29(12"CONC E) IE-361.19(12"CONC W) BOT=360.59 30' D o Ln D. 0 20 40 1 "=20' EXISTING ROAD ABOVE SEWER EX 12" STORM 0 .......................................................360............. ........................................................ ............................................................................360.......... ° PROPOSED REMOVE EX. 6" CLAY SEWER. -AND 1n 12" STORM REPLACE WITH 47B LF OF 8 PVC @ 4 84� MH #16 W Lid 161 1 1"17% N ....................................................... 3�0.......................................................................................................................................................................................35o........ N 175216 f7 ' 17521619...................... N MM #98 E 138293841 1302937 82 w N: 174861. 174861.74 MH #17 REMOVE EX MH & E "'"'^',�vzs2Ar✓` 1302929.15 � N " 175042"81 REPLACE WITH NEW 54" SHALLOW MH ......340.............. REMOVE. EX MH.&.... ................................................ E 430 98'1302933:95............... :......... :.........:.........:.........:............... .340........ R/M- .364-9t:.364 07..:.........:.........:.. REPLACE WITH NEW 54"MH REMOVE EX CO & JE 10" W = 359H9 359.17 RIM = 364.9+ 364.77. REPLACE WITH NEW:54" SHALLOW MH JE 10" E = 359.20 359.27 lE 6` W = 36745 351.10 R/M = 364.54 364.48: lE 8" N = 359 20 359"32 .......................................................330..............1E 6" E =.357-&..357.45........:....................................../E 8" S = 359 33 359.1.3 .................. ................................ ...................... 330..................................................... lE 8" N = 357-.55 35724 EXISTING • EXISTING UTILITIES ARE SHOWN FOR • ONE -CALL REFERENCE ONLY. CONTRACTOR SHALL F1-800-424-5555 UTILITIESI ELD A MINIMUMS OFL722 HOURS Know whars below. PRIOR TO CONSTRUCTION. ,,- Call before you dig. AERICAN SURVEYING & ENVIRONMENTAL, )INDUCTED AN AS -BUILT SURVEY OF ALL -WLY CONSTRUCTED SANITARY SEWER 'STEM TO PREPARE THESE FINAL RECORD 2AWINGS. THE RECORD DRAWINGS REFLECT 1E AS -CONSTRUCTED CONDITIONS BASED V FIELD SURVEY DATA AND SHOULD BE ELD VERIFIED FOR ANY FUTURE USE. ALL WITARY SEWER SYSTEM STRUCTURES ERE FIELD SURVEYED IN THEIR AS -BUILT )CATIONS AND ACCURATELY REFLECTED -REON. �67 02-0161 moil BRH DESIGNED: JDH DRAWN: JDH CHECKED: JDH, MAB BY DATE APPR APPROVED: DMC VENDAL. HAD 19 99 CITY OFRENTON HILL UTILITY REPLACEMENT APR 2017 HORIZONTAL: NAD 19i gas 1 1 "=20' �If >= Fl¢neDDK: RENTON P SANITARYSEWERPACE:ONE INCH DATUM DRAWING NO: AT FULL SCALE Planning/Building/Public Works Dept. S-10 IF NOT ONE INCH SCALE ACCORDINGLY HIGH AVE S SHEEP: 61 OF:Q n ISI-10131e12141