HomeMy WebLinkAboutD-382406EXISTING UTILITY
DATA
GENERAL NOTES
MEASUREMENT TO TOP OF
MEASUREMENT TO BOTTOM OF
v
c�
POTHOLE #
TYPE OF UTILITY
MATERIAL
SIZE OF UTILITY
UTILITY FROM GROUND
UTILITY FROM GROUND
NOTES
1. ALL GAS POTHOLE INFORMATION PROVIDED BY PUGET SOUND
co
ENERGY.
Tl
COMM
PVC
2"
22"
24"
JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE El.
T2
COMM
D.B.
5/8"
40"
41"
JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE E2.
N
T3
COMM
PVC
(2)1", 2"
19"
23"
JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE E4 -E5.
CL
T4
COMM
D.B.
5/8"
35"
36"
JOINT TRENCH WITH POWER CONDUIT. SEE POTHOLE E8.
Cl
CN
PVC
2"
11.5"
13.5"
c/)
C2
CTV
CONC DUCT
5"x16"
6"
22"
C3
N/A
N/A
N/A
N/A
N/A
UNABLE TO LOCATE.
LU
El
POWER
PVC
4"
21"
25"
JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE Tl.
N
E2
POWER
PVC
(2) 4"
40"
44"
JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE T4.
E3
POWER
PVC, D.B.
(2)1/4", (2)1", 2", 3"
35"
47"
POSSIBLE ADDITIONAL POWER AND COMM IN JOINT TRENCH.
m
E4 -E5
POWER
PVC
(2) 4"
24"
28"
JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE T3.
E7
POWER
PVC
(2)1", 2"1 6"
35"
51.5"
POSSIBLE COMM LOCATED IN JOINT DUCT BANK.
E8
POWER
PVC
5/8", (2) 2", (2) 4"
34"
40"
JOINT TRENCH WITH COMM CONDUIT. SEE POTHOLE T4.
Wl
WATER
STEEL
8"
24"
32"
W2
WATER
STEEL
66"
38"
104"
W3
WATER
STEEL
54"
37"
91"
W4
WATER
STEEL
66"
30"
96"
W5
WATER
DUCTIL IRON
10"
79"
89"
W6
WATER
DUCTIL IRON
6"
36"
42"
W7
WATER
CAST IRON
8"
55"
63"
W8
WATER
CAST IRON
4"
48"
52"
W9
WATER
IRON/STEEL
4"
39"
43"
W10
N/A
N/A
N/A
N/A
N/A
UNABLE TO LOCATE.
Si
SEWER
PVC
6"
45"
51"
52
SEWER
CLAY
6"
52"
58"
S3
SEWER
CLAY
6"
54"
60"
S4
SEWER
CLAY
6"
46"
52"
55
SEWER
CONC
8"
146"
152"
S6
SEWER
CONC
8"
69"
77"
57
SEWER
CONC
8"
91"
99"
S8
SEWER
CLAY
12"
67"
79"
G1
GAS
STW
8"
41"
49"
G2
GAS
STW
8"
45"
53"
G3
GAS
PE
2"
47"
49"
G4
GAS
PE
4"
37"
41"
G5
GAS
PE
2"
30"
32"
a
G6
GAS
STEEL CASED
2"
32"
34"
G7
GAS
STW
2"
34"
36"
G8
GAS
STW
2"
32"
34"
0
G9
GAS
STW
2"
30"
32"
G10
GAS
STW
2"
36"
38"
Gil
GAS
STW
2"
30"
32"
E
G12
GAS
STW
2"
26"
28"
G13
GAS
STW
2"
26"
28"
G20
GAS
STW
2"
24"
26"
G21
GAS
STW
2"
31"
33"
G22
GAS
STW
8"
37"
45"
E
ED
G23
GAS
STW
8"
27"
35"
E
e
G24
GAS
STW
8"
21"
29"
G25
N/A
N/A
N/A
N/A
N/A
UNABLE TO LOCATE.
E
G26
GAS
STW
8"
24"
32"
G27
GAS
STW
2"
21.5"
23.5"
=
G28
GAS
STW
2"
25"
27"
3
G29
GAS
PE
2"
27"
29"
G30
GAS
PE
2"
31"
33"
G31
GAS
PE
2"
29"
31"
SOFT SURFACE, NO ASPHALT.
G32
GAS
STW
2"
42"
44"
G33
GAS
STW
2"
34"
36"
G34
GAS
STW
2"
46"
48"
Al
CTV/POWER
PVC
211,311
33"
35"
GROUNDWATER IN POTHOLE. POSSIBLE ADDITIONAL CONDUITS UNDERNEATH.
RECOMMENDED FOR APPROVAL By
A2
COMM
CONIC DUCT
301140"
22"
32"
JOSEPH FARAH
A2-1
COMM
CONIC DUCT
20'1
27"
48"
SURFACE WATER UTILITYENGINEER
A3
COM/TV/PWR
PVC
(2) 2"1 3"
28"
33"
JOINT TRENCH COMM/TV/PWR
S. at
4A
POWER
PVC
2"
36"
38"
vy
W
Q of r 11'
�¢°°E
•
As NOTED
°"VERTII NAST °" e'"ss'
CITY OF
RENTON HILL UTILITY REPLACEMENT PROJECT
STORM SYSTEM IMPROVEMENTS
os/os/zon
DESIGNEJE
E'E`°"°°"
Louis Berger
ML RE \TO \
PAGE
RAW
ABG
ONE INC"
I
°� N
a
°m R�'cts'rEgE° �w
�{�T�V
G7
BID SET
MSG
05/05/2017
MSG
"�
IL
�`gsrotvnt ����
�"°TE ACOOE"NOL.
PlanningBuilding/Public Works Dept.
POTHOLE SCHEDULE
" VED
a PMSG
s"EE,: 8 OF 89
w
/05/17
520 Pike St, Ste 1005, Seattle, WA 98101 206.453.1043
N0.
REVISION
BY
DATE
APPR
S
W
P
-
3
8
2
4