HomeMy WebLinkAboutD-382421v N 00 N N a W 0 CIO CLEANOUT SEE NOTE 5 0.05 FT/FT �... MIN SLOPE I FT — EX SIDE SEWER i EX TEE z SEE NOTE 1 � SUBGRADE 6" REMOVE CONFLICTING SIDE SEWER EX PAVEMENT NEW STORMWATER PIPE SELECT IMPORTED SIDE SEWER RELOCATION ABOVE NEW STORM PIPE (TYP) TRENCH BACKFILL IN CLEANOUT ACCORDANCE WITH COR SEE NOTE 5 STANDARD SPECIFICATIONS- - EX TEE SEE NOTE 1 NEW 6" SIDE SEWER 0.02 FT/FT EX SEWER MAIN MIN SLOB � NEW STORMWATER PIPE REMOVE CONFLICTING SIDE SEWER —FOAM BLOCK, SEE NOTE 4 , SIDE SEWER RELOCATION BELOW NEW STORM PIPE (TYP) EX SIDE SEWER CONNECT SIDE SEWER WITH "STRONG—BACK" FLEXIBLE COUPLING INSTALL 6'W REDUCER IF NEEDED 1/8, 1/16, OR 1/32 BENDS AS NEEDED NOTES: 1. IF EXISTING TEE IS NOT USEABLE FOR RECONNECTION, SEE STANDARD PLAN 406.1 FOR ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN. 2. CONCRETE BLOCK REQUIRED AT NEW SADDLE WHEN ANGLE AT MAIN EXCEEDS 25'. SEE CITY OF RENTON STANDARD PLAN 406.1. 3. ALLOWABLE SIDE SEWER PIPE AND FITTINGS: POLYVINYL CHLORIDE (PVC) SDR 35 OTHER MATERIAL, AS APPROVED BY CITY INSPECTOR. 4. FOR 3" SEPARATION INSTALL 1'x2'x2" THICK STYRENE FOAM BLOCK BETWEEN NEW PIPE AND 6" SIDE SEWER RELOCATION. 5. IF NEW SD CONFLICTS WITH A CLEAN OUT RISER, RELOCATE AND INSTALL NEW CLEANOUT PER CITY OF RENTON STANDARD PLAN 406.1 AT LOCATION APPROVED BY ENGINEER. 6. ALL SIDE SEWER RECONSTRUCTIONS SHALL BE APPROVED BY CITY INSPECTOR. 7. PAYMENT FOR SIDE SEWER RELOCATION ONLY APPLIES WHERE SIDE SEWERS ARE NOT REPLACED AS A PART OF SCHEDULE C. WHERE THEY ARE REPLACED AS PART OF SCHEDULE C, THEY SHALL BE INSTALLED TO AVOID CONFLICT WITH NEW STORM. DETAIL 1 SIDE SEWER RELOCATION G5 SCALE: NTS 1 6" 0 1"=1'-0" mm&I Scale 2 1 3/4"=1'-0" 1!!I Scale A 2 Feet 2 Feet �a 4 Louis Berger ns�gE°tew �. 520 Pike St, Ste 1005, Seattle, WA 98101 -288.453.1043 N0. CONSTRUCTION GEOTEXTILE FOR SEPARATION WHERE REQUIRED BY ENGINEER — SAWCUT TRENCH WIDTH = PIPE ID + 30" (15" DIA PIPES AND SMALLER) 1.5 x PIPE ID + 18" (18" DIA PIPES AND LARGER) SEE TRENCH PAVEMENT PATCH AND PAVEMENT RESTORATION REQUIREMENTS ON DWGS D1 AND D2. )AX 1'-0„ — — MAX �r/T' t REPLACE UNSUITABLE FOUNDATION MATERIAL WHERE REQUIRED BY ENGINEER. UNLESS OTHERWISE DIRECTED BY ENGINEER NEW MATERIAL SHALL BE QUARRY SPALLS REDUCING SECTION PER COR STD. PLAP (MAY NEED MORE TI TO ACHIEVE GRADE) BID SET REVISION 55 NOTES: 1. SEE DWGS D1 AND SAWCUT D2 FOR HMA & CSTC THICKNESS. [.911 IH:7111� EX PAVEMENT PIPE ZONE BEDDING 6" MIN ABOVE PIPE �� s'Eziriss1 �, GRAVEL BACKFILL FOR PIPE ZONE BEDDING IN ACCORDANCE WITH COR STANDARD SPECIFICATIONS TRENCH WIDTH PAY LIMIT DETAIL r2 TYPICAL TRENCH — SCALE: 1"=l'—O" 2'-10 1/8" PIPE ZONE BEDDING 6" MIN BELOW PIPE 1ND FRAME AND COVER COR STD. PLAN 204.50 FLAT TOP SLAB 4 I M 3'-0" CATCH BASIN TYPE 1L PER COR STD. PLAN 200.10 DETAIL 5 TYPE 1L CB WITH CIRCULAR LIDSW12 SCALE: 3/4'1 AS NOTED DESIGNED TE wry JTEorve wce MSG 05/05/2017 MSG KEc oMaw IF INCHONE BY DATE APPR Sc LEFF E xcoaowcIFr PPR PMSG DETAIL 3 ASPHALT WEDGE CURB — SCALE: 1"=l'—O" 8" NOTES: CLASS "B" 1. 8" AND 6" CLEAN—OUT RINGS AND ASPHALT 2'-0° FRAME COVERS SHALL BE EAST JORDAN IRON DIA 2,_0„ WORKS, INC. NO. 3698 (PRODUCT N0. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. CAST IRON RING AND COVER 2. IN UNIMPROVED AREAS, POUR A V-0" AND WATER TIGHT PLUG PER THICK, 2'-0" SQUARE CONCRETE, COR STD. DETAIL 403.1 CLASS 3000, PAD AROUND THE RING AND COVER. 3. INCLUDE 45' BEND(S) (ONE OR TWO) 6" OR 8" 45' 1/8 BENDS WHERE GREATER DEPTH IS NEEDED TO CONNECT TO MAIN, OR WHERE NEEDED 6 TO AVOID UTILITY CONFLICT. 6" OR S" WYE—,,,,\\yy� 6" OR 8"--, TO STORM MAIN 0.02 FT/FT MIN SLOPE m Of W U U FLAT TOP SLAB Wo 13" 3 DUND FRAME AND COVER ER COR STD. PLAN 204.50 EDUCING SECTION ER COR STD. PLAN 200.10 ;ATCH BASIN TYPE 1L 'ER COR STD. PLAN 200.10 6 OR 8" 45' 1/8 BEND (SEE NOTE 3) CONNECT TO EX 6" OR 8" LATERAL DETAIL 4 STORM LATERAL CLEANOUT SW8 SCALE: 1"=l'—O" FRAME & GRATE NOTES: TOP OF ROADWAY 1. INSTALL CB SUCH THAT FRAME AND GRATE ABUTS THE FACE OF THE CURB. ADJUSTMENT SECTION 2. ADJUSTMENT SECTIONS SHALL BE INSTALLED TO FINISHED GRADE USING GROUT IN A TYPE 2 CONTINUOUS LAYER BETWEEN CATCH BASIN CB TOP AND ADJUSTMENT SECTION. DETAIL s TYPE 2 CB GUTTER LINE PLACEMENT G5 SCALE: 1"=V-0" PIPE MATERIAL AS SPECIFIED BY THE ENGINEER RECOMMENDED FOR APPROVAL BY JOSEPH FARAH SURFACE WATER UTILITYENGINEER � l�1 HaR.orv. rv�°P8°,ss, RENTON HILL UTILITY REPLACEMENT PROJECT 05/05/2017 CITY OF STORM SYSTEM IMPROVEMENTS ""°BOOK MIL RENTON E. °AT"M IDC NO Planning/Building/Public works Dept SW 15 CIVIL DETAILS 1 OF 2 SHEET. OF, 48 89 S W P 3 8 2 4