Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T-400505
Lf) O O O SIGNAL & ILLUMINATION GENERAL NOTES 1. CONTRACTOR SHALL CHECK FOR OVERHEAD VERTICAL CLEARANCE REQUIREMENTS PER SHEET TS-04 FOR ALL SIGNAL HEADS ABOVE THE STREET PRIOR TO POURING OF FOUNDATION. 2. ALL TRAFFIC SIGNAL AND PEDESTRIAN HEADS AND PUSH BUTTONS SHALL BE SECURELY AND COMPLETELY COVERED WHILE NOT IN OPERATION. 3. JUNCTION BOXES SHALL BE PLACED OUTSIDE OF PAVEMENT SURFACE AND WHEELCHAIR RAMPS UNLESS OTHERWISE INSTRUCTED BY THE ENGINEER. 4. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS AND THE CURRENT EDITION OF THE CITY OF RENTON STANDARD SPECIFICATIONS AND DETAILS. THE CURRENT EDITION OF THE CITY OF RENTON STANDARD SPECIFICATIONS AND DETAILS SHALL BE CONSIDERED PART OF THIS CONTRACT. 5. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 6. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE INSPECTOR FOR MATERIALS APPROVAL THREE WEEKS PRIOR TO REQUESTED APPROVAL DATE. 7. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 9. EXISTING FEATURES TO REMAIN UNLESS OTHERWISE NOTED. 10. ALL CONDUCTORS FOR SIGNAL HEADS, LOOPS, PEDESTRIAN HEADS, PUSHBUTTONS, AND STREET LIGHTS SHALL BE LABELED IN EACH JUNCTION BOX. 11. ALL SIGNALIZED CROSSWALKS SHALL BE OPERATIONAL AT ALL TIMES UNLESS FLAGGERS/POLICE ARE PRESENT TO ASSIST PEDESTRIANS. 12. CONTRACTOR SHALL PROVIDE TENW WITH REDLINE MARKUPS SHOWING ANY AND ALL CHANGES FROM THESE APPROVED PLANS FOLLOWING CONSTRUCTION. 13. SIGNAL POLE BASE PLATES AND FACE OF PUSHBUTTONS SHALL ALIGN WITH THE BEARING OF THE CROSSWALK IT SERVES. FAILURE TO ORIENT POLES/BASE PLATES WITH THE CROSSWALK WILL REQUIRE THE FOUNDATION TO BE REMOVED AND RE -POURED BY THE CONTRACTOR. SEE SIGNAL POLE PLACEMENT DETAILS, THIS SHEET. 14. CONTRACTOR SHALL CONFIRM PREFERRED TRENCHING/BORING METHOD WITH CITY OF RENTON PRIOR TO BEGINNING CONSTRUCTION. 15. TRAFFIC SIGNAL, ILLUMINATION AND INTERCONNECT CONDUIT SHALL BE PLACED SUCH THAT IT WILL NOT CONFLICT WITH FUTURE STREET TREE OR STRUCTURE INSTALLATIONS. VERIFY CONDUIT PLACEMENT WITH ENGINEER PRIOR TO BEGINNING CONSTRUCTION. 16. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER SIGNAL DISPLAYS 18" 12" 12" (R 12" OR 12" OR 12" � 12" O 12" O 12" O I 12" � 12" OG 12" OG 12" OG VEHICLE HEADS 12" 12"zEl"/ VEHICLE HEADS EX: 11 VEHICLE HEADS VEHICLE HEADS EX: 31/OLC,32/OLC PEDESTRIAN HEADS RELOCATE. 52 EX! A2 EX: A11OLD B1 B2,B3 EX: 28,29 NEW. 51 41,42 38,39 61,62 48,49 RELOCATE: 21,22 88,89 ALL VEHICLE AND PEDESTRIAN DISPLAYS SHALL BE LED. ALL VEHICLE HEADS SHALL HAVE 12" LENSES AND TYPE M MOUNTS (CONNECTED BETWEEN THE RED AND YELLOW SIGNAL FACES). ALL PEDESTRIAN HEADS ON TYPE 11 OR III POLES SHALL USE TYPE E CLAMSHELL MOUNTS. PEDESTRIAN HEADS ON POLE 2 (TYPE PS) SHALL USE TYPE C TOP MOUNT AND ON TYPE I POLES SHALL USE TYPE B MOUNT. / Il I I 1 I / I I II I I 17. FOR SIGNAL SYSTEM COORDINATION WITH THE CITY OF RENTON, CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC I CUTSHALL 425-430-7423. / 18. ALL JUNCTION BOXES SHALL BE LABELED CORRECTLY LIGHTING, SIGNAL ITS. ALL COVERS LIDS WITHIN PAR PEDESTRIAN ACCESS ROUTE _ ( )) i (( ) STANDARD PLAN 512Y, CURRENT/EDIT RESISTANT. JUNCTION BOXES OUTSIDE (SF SfhEWALK MUST HAVE CONCRETE PAD PER CITY OF RENTON I J 19. ALL PUSH BUTTONS SHALL BE POLARA I NAVIGATOR WITH ONE (1) PROGRAMMING NOTE FOR THE ENTIRE INTERSECTION. \ I c I 19TENW Transportation Engineering North West iron nning I °sign I Traffic lm°acl a a� ,Irn, wgse er I�ei ss)eew-eia711e WA F Protect Contact: Elyse St—ler. P.E. I 1:70 \� 9 1 17 F \I Cq<\ q�?S BCOw 1 1 1 1 PHASE DIAGRAM EXISTING PROPOSED 01 05 01 05 02 06 02 06 04 08 04 08 03 03OLA 07 07 PROTECTED VEHICLE MOVEMENT 1` PERMISSIVE VEHICLE MOVEMENT — -- PEDESTRIAN MOVEMENT PREEMPT 1 (RR) = TRACK: OLA & OLB, DWELL: 02 & 06 PREEMPT 2 (RR) = TRACK. 01, 06 &OLB, DWELL., 05, OLB, OLC & OLD PREEMPT 3 (EVP C) = DWELL: 02, 05 & OLB PREEMPT 4 (EVP D) = DWELL: 04 & OLA PREEMPT 5 (EVP E) = DWELL: 01, 06 & OLB PREEMPT 6 (EVP F) = DWELL: OLA & OLC �OLC ��LB + s OLD SBLT � � NBL i�iLC ��LB NBT � SBT N— r�}► 4 OLD OLA NOT USED OLCI +ir OLB NOT USED �OLC ��LB + s OLD SBLT � � ♦NBL LC YOWL NBT 1 �►I SBT N— OLD OLCI i OLB OLA SIGNAL AND ILLUMINATION LEGEND EX NEW/RELOCATE DESCRIPTION 71 El m m 0 JUNCTION BOX TYPE 1,2,8 L 444-LA ELECTRICAL VAULT VEHICLE SIGNAL HEAD -#-► PEDESTRIAN SIGNAL HEAD VIDEO DETECTION CAMERA LUMINAIRE POLE SIGNAL POLE TYPE III I I FI`-------- SIGNAL POLE TYPE SD TYPE PPB OR PS POLE F PPB EMERGENCY PRE-EMPTION DETECTOR 7�# GPS OPTICOM — — — — — — CONDUIT/CONDUCTOR ® ELECTRICAL SERVICE CABINET ® CONTROLLER CABINET p. UTILITY POLE UTILITY POLE MOUNTED LIGHT OCONSTRUCTION NOTE SIGNAL AND LUMINAIRE POLE NUMBER/CONSTRUCTION NOTE 29 SIGNAL & ILLUMINATION CONSTRUCTION NOTES: I ` m 3 L 0 EXISTING TYPE SD SIGNAL POLE AND ASSOCIATED EQUIPMENT TO REMAIN UNLESS OTHERWISE NOTED. INSTALL ONE NEW R3-8L o SIGN WITH BACK OF SIGN PAINTED BLACK AND RELOCATE EXISTING VEHICLE HEADS 52 21 22 AND EVP A PER POLE SCHEDULE SHEET TS-04. REMOVE EXISTING VIDEO DETECTION CAMERA 2 AND INSTALL ONE NEW VECTOR VIDEO DETECTION CAMERA AS o I DIRECTED BY THE ENGINEER. FIELD WELD NEW TENONS FOR SIGNAL DISPLAYS 52, 21 AND 22. REMOVE EXISTING CONDUCTORS o FROM MAST ARM PRIOR TO WELDING. RE —INSTALL CONDUCTORS TO VEHICLE SIGNAL DISPLAYS, PRE—EMPT DETECTOR AND CAMERA FOLLOWING THE COMPLETION OF WELDING ACTIVITY. RETURN SALVAGED VIDEO DETECTION CAMERA 2 TO CITY OF RENTON \ TRANSPORTATION SIGNAL/SIGN SHOP. O2 EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. I� R`,L p3 EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. h OEXISTING TYPE III SIGNAL POLE AND ASSOCIATED EQUIPMENT TO REMAIN UNLESS OTHERWISE NOTED. INSTALL ONE NEW VEHICLE 4 HEAD 51 ON THE BACKSIDE OF THE POLE AND ONE NEW GPS OPTICOM PER POLE SCHEDULE, SHEET TS-04. FIELD WELD NEW TENON FOR SIGNAL DISPLAY 51. REMOVE EXISTING CONDUCTORS FROM MAST ARM PRIOR TO WELDING. RE -INSTALL CONDUCTORS �i TO VEHICLE SIGNAL DISPLAYS, PRE-EMPT DETECTOR AND CAMERA FOLLOWING THE COMPLETION OF WELDING ACTIVITY. 11 O5 EXISTING TYPE PPB POLE TO REMAIN. PROTECT DURING CONSTRUCTION. © EXISTING TYPE SD SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. O7 EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. ® EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. p EXISTING TYPE / SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. l ® EXISTING TYPE PPB POLE TO REMAIN. PROTECT DURING CONSTRUCTION. \© EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. © EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. © EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. ® EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. 13 0 1 / ZO EXISTING CONTROLLER AND SERVICE CABINET TO REMAIN. PROTECT DURING CONSTRUCTION. 4 \ O I � 3 EXISTING DECORATIVE LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION. W O CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. FURNISH AND INSTALL ONE NEW 135W DOMUS DECORATIVE LUMINAIRE ON NEW FOUNDATION. OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. RELOCATE EXISTING DECORATIVE LUMINAIRE TO NEW 5 FOUNDATION. REMOVE EXISTING FOUNDATION TO A MINIMUM 24" BELOW SURFACE GRADE. FILL AND COMPACT VOID. O6 REMOVE EXISTING LUMINAIRE AND RETURN TO THE CITY OF RENTON TRANSPORTATION SIGNAL/SIGN SHOP. REMOVE EXISTING FOUNDATION TO A MINIMUM 24" BELOW SURFACE GRADE. FILL AND COMPACT VOID. O SPLICE NEW ILLUMINATION CONDUCTORS WITH EXISTING ILLUMINATION CONDUCTORS IN EXISTING JUNCTION BOX. 0 H. - OINSTALL NEW TA-25 FIBER VAULT PER WSDOT STANDARD PLAN J-40.36. COORDINATE WITH CITY OF RENTON'S TRANSPORTATION MAINTENANCE MANAGER ERIC CUTSHALL, 425-430-7423, ON DISCONNECTING EXISTING CITY FIBER AND PULLING IT BACK TO THE EXISTING SIGNAL CABINET ON THE NW CORNER OF SOUTHPORT DR. N AND SITE ACCESS. INTERCEPT EXISTING 4" CONDUIT WITH CITY FIBER AT NEW TA-25 LOCATION. ONCE ALL CONDUITS HAVE BEEN RECONNECTED, REMOVE EXISTING TA-25 FIBER VAULT. FILL AND COMPACT VOID. NTERCEPT f 0 ILLUMINATION OEXTEND CONDUCTORS EXISTING TOCONDUCOTORSI INFROM EXISTING NEW JUNCTIONT BOX, AS NECESSARY. VAULT OR ETD NEW JUNCTION BOX. SPLICE EXISTING it REMOVE EXISTING TYPE 1 JUNCTION BOX AND INSTALL ONE NEW TYPE 2 JUNCTION BOX. T-40O505 19 / 10 20 10 40 20 0 20 60 _ SCALE IN FEET 2 FIBER VAULT AND LIGHT POLE CONFLICT JLS 11/06/18 "YFtr 3 SIGNAGE REVISIONS EMS 01/28/19 xn isv"�� 4 LIGHTING & SIGNAGE REVISIONS EMS 03/20/19 ° JLS AS-BUILTS HW 09/04/19 JLS m EMS �� DATUM NO. REVISION BY DATE APPR °R0 CT6 5C4E "C .I— 00 IN COMPLIANCE WITH CITY OF RENTON STANDARDS O CITY OF TRAFFIC SIGNAL PLAN io/o1/Zo1 RENTON LAKE WA BLVD IMPROVEMENTS PHASE III FOR SOUTHPORT DEVELOPMENT Planning/Building/Public works Dept. 1083 LAKE WASHINGTON BLVD N �TS-01 RENTON, WA 98055 �^�° „ OA,o rn O O r U f,0 Lf) O O Q J N 00 O O O O ii OCONSTRUCTION NOTE SIGNAL AND LUMINAIRE POLE NUMBER/CONSTRUCTION NOTE 29 SIGNAL & ILLUMINATION CONSTRUCTION NOTES: I ` m 3 L 0 EXISTING TYPE SD SIGNAL POLE AND ASSOCIATED EQUIPMENT TO REMAIN UNLESS OTHERWISE NOTED. INSTALL ONE NEW R3-8L o SIGN WITH BACK OF SIGN PAINTED BLACK AND RELOCATE EXISTING VEHICLE HEADS 52 21 22 AND EVP A PER POLE SCHEDULE SHEET TS-04. REMOVE EXISTING VIDEO DETECTION CAMERA 2 AND INSTALL ONE NEW VECTOR VIDEO DETECTION CAMERA AS o I DIRECTED BY THE ENGINEER. FIELD WELD NEW TENONS FOR SIGNAL DISPLAYS 52, 21 AND 22. REMOVE EXISTING CONDUCTORS o FROM MAST ARM PRIOR TO WELDING. RE —INSTALL CONDUCTORS TO VEHICLE SIGNAL DISPLAYS, PRE—EMPT DETECTOR AND CAMERA FOLLOWING THE COMPLETION OF WELDING ACTIVITY. RETURN SALVAGED VIDEO DETECTION CAMERA 2 TO CITY OF RENTON \ TRANSPORTATION SIGNAL/SIGN SHOP. O2 EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. I� R`,L p3 EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. h OEXISTING TYPE III SIGNAL POLE AND ASSOCIATED EQUIPMENT TO REMAIN UNLESS OTHERWISE NOTED. INSTALL ONE NEW VEHICLE 4 HEAD 51 ON THE BACKSIDE OF THE POLE AND ONE NEW GPS OPTICOM PER POLE SCHEDULE, SHEET TS-04. FIELD WELD NEW TENON FOR SIGNAL DISPLAY 51. REMOVE EXISTING CONDUCTORS FROM MAST ARM PRIOR TO WELDING. RE -INSTALL CONDUCTORS �i TO VEHICLE SIGNAL DISPLAYS, PRE-EMPT DETECTOR AND CAMERA FOLLOWING THE COMPLETION OF WELDING ACTIVITY. 11 O5 EXISTING TYPE PPB POLE TO REMAIN. PROTECT DURING CONSTRUCTION. © EXISTING TYPE SD SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. O7 EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. ® EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. p EXISTING TYPE / SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. l ® EXISTING TYPE PPB POLE TO REMAIN. PROTECT DURING CONSTRUCTION. \© EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. © EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. © EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. ® EXISTING TYPE PS SIGNAL POLE TO REMAIN. PROTECT DURING CONSTRUCTION. 13 0 1 / ZO EXISTING CONTROLLER AND SERVICE CABINET TO REMAIN. PROTECT DURING CONSTRUCTION. 4 \ O I � 3 EXISTING DECORATIVE LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION. W O CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. FURNISH AND INSTALL ONE NEW 135W DOMUS DECORATIVE LUMINAIRE ON NEW FOUNDATION. OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. RELOCATE EXISTING DECORATIVE LUMINAIRE TO NEW 5 FOUNDATION. REMOVE EXISTING FOUNDATION TO A MINIMUM 24" BELOW SURFACE GRADE. FILL AND COMPACT VOID. O6 REMOVE EXISTING LUMINAIRE AND RETURN TO THE CITY OF RENTON TRANSPORTATION SIGNAL/SIGN SHOP. REMOVE EXISTING FOUNDATION TO A MINIMUM 24" BELOW SURFACE GRADE. FILL AND COMPACT VOID. O SPLICE NEW ILLUMINATION CONDUCTORS WITH EXISTING ILLUMINATION CONDUCTORS IN EXISTING JUNCTION BOX. 0 H. - OINSTALL NEW TA-25 FIBER VAULT PER WSDOT STANDARD PLAN J-40.36. COORDINATE WITH CITY OF RENTON'S TRANSPORTATION MAINTENANCE MANAGER ERIC CUTSHALL, 425-430-7423, ON DISCONNECTING EXISTING CITY FIBER AND PULLING IT BACK TO THE EXISTING SIGNAL CABINET ON THE NW CORNER OF SOUTHPORT DR. N AND SITE ACCESS. INTERCEPT EXISTING 4" CONDUIT WITH CITY FIBER AT NEW TA-25 LOCATION. ONCE ALL CONDUITS HAVE BEEN RECONNECTED, REMOVE EXISTING TA-25 FIBER VAULT. FILL AND COMPACT VOID. NTERCEPT f 0 ILLUMINATION OEXTEND CONDUCTORS EXISTING TOCONDUCOTORSI INFROM EXISTING NEW JUNCTIONT BOX, AS NECESSARY. VAULT OR ETD NEW JUNCTION BOX. SPLICE EXISTING it REMOVE EXISTING TYPE 1 JUNCTION BOX AND INSTALL ONE NEW TYPE 2 JUNCTION BOX. T-40O505 19 / 10 20 10 40 20 0 20 60 _ SCALE IN FEET 2 FIBER VAULT AND LIGHT POLE CONFLICT JLS 11/06/18 "YFtr 3 SIGNAGE REVISIONS EMS 01/28/19 xn isv"�� 4 LIGHTING & SIGNAGE REVISIONS EMS 03/20/19 ° JLS AS-BUILTS HW 09/04/19 JLS m EMS �� DATUM NO. REVISION BY DATE APPR °R0 CT6 5C4E "C .I— 00 IN COMPLIANCE WITH CITY OF RENTON STANDARDS O CITY OF TRAFFIC SIGNAL PLAN io/o1/Zo1 RENTON LAKE WA BLVD IMPROVEMENTS PHASE III FOR SOUTHPORT DEVELOPMENT Planning/Building/Public works Dept. 1083 LAKE WASHINGTON BLVD N �TS-01 RENTON, WA 98055 �^�° „ OA,o rn O O r U f,0 Lf) O O Q J N 00 O O O O ii 00 IN COMPLIANCE WITH CITY OF RENTON STANDARDS O CITY OF TRAFFIC SIGNAL PLAN io/o1/Zo1 RENTON LAKE WA BLVD IMPROVEMENTS PHASE III FOR SOUTHPORT DEVELOPMENT Planning/Building/Public works Dept. 1083 LAKE WASHINGTON BLVD N �TS-01 RENTON, WA 98055 �^�° „ OA,o rn O O r U f,0 Lf) O O Q J N 00 O O O O ii