REPLACEMENT REQUIREMENTS
• LOOP E SHALL BE IMSA 51-7 #12 OR #14 IN ORANGE PVC JACKET.
• LOOP INSTAL N SHALL FOLLOW WSDOT STANDARD PLAN J-50.12 AND J-50.15-01.
• LOOP INSTALLATION SH NOT TAKE PLACE IN TEMPERATU BELOW 40 DEGREES.
• LOOPS SHALL NOT BE SEALED N THERE IS MIDI RE ON THE GROUND.
• THE SAW CUTS SHALL BE OF UNIFORM S AND ANY SHARP EDGES, ABRASIONS, OR
RIDGES SHALL BE REMOVED PRIOR RO CI THE WIRE.
• ALL LOOPS SHALL BE INSTAL IN THE FINAL LEFT ASPHALT DESIGNATED IN THE
CONTRACT. LOOP CONDUC S SHALL BE HELD AT THE B OM OF THE SAW CUT BY
HIGH TEMPERATURE B ERS ROD SIZED TO FIT SNUGGLY IN SAWS CENTER ALONG
THE ENTIRE LOO ND HOME RUN(S) AND AT THE ENTRANCE AND T OF ALL TURNS
GREATER TA 45 DEGREES. IF NEW LOOPS ARE INSTALLED OVER EXIST LOOPS, THE
OLD LO SHALL BE REMOVED BY GRINDING AND THE GRINDING SHALL B OUGH TO
DE OY ANY EXISTING OPERATIONAL LOOP CONDUCTORS.