Loading...
HomeMy WebLinkAboutS-396108V SEC. 14, TWP 23 N, R5E vv.k N I- Q n W O 0 a 5W L a z U_ C P CONSULTANTS Site Planning - Civil Engineering Land Use Consulting - Project Management 11431 WILLOWS RD. NE, SUITE 120 REDMOND, WA 98052 Phone: (425) 285-2390 1 FAX: (425) 285-2389 www.cphconsultants.com 7' MANHOLE FRAME AND COVER SEE STD. PLAN 401 ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 MORTAR JOINT(S) (3/8" MIN.) SEE NOTE 5 CONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE - 'E' CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. NOT TO SCALE A' I 'B' I 'C' I 'D' I 'E' 48" MH 48" 6" MIN. 5"MIN 24 MIN. 21" I.D. 54" MH 54" 8" MIN. MIN. 24" MIN. 24 I.D. 60 MH 60" B" MIN, 1 6" MIN. 1 42" MIN. 1 30" I.D. NOTES; 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING SHALL BE PER STD. PLAN 401. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. 6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. 10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. 11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. - 400.1 PUBLIC WORKS STANDARD SANITARY MANHOLE p=•`Z DEPARTMENT FNTo SEPTEMBER 2011 W (SEE NOTE 7) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) FOUNDATION LEVEL LIMITS OF PIPE ZONE RM .D. OF PIPE BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)' OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. PUBLIC WORKS I PIPE BEDDING DEPARTMENT FOR SANITARY SEWERS STD, PLAN - 405 BOLTHOLES - 3 PLCS EQUALLY SPACED 120" APART ON 23 1/16' (586mm) DIA B.C. (SEE DETAIL) COVER & FRAME PLAN VIEW 25' DIA, C635r 3 1° 3/4' �25rM7 119mm7 11L B 3�t 2 1/2' 1222mm7 164mm7 TYP COVER SECTION VIEW 26 1/2' DIA C673mm7 25 1/4' DIA 1641 1 1/16' 1/4' (6­) DIA � 127mm] NEOPRENE GASKET 1 6' C152mm] 1 5/8' I 23 3/8DIA CL OPEN I I I C16mm7 COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 5/8' 11 X 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4' 1 1/16' 127mm) C3mm] CR3mm] GASKET GROOVE DETAIL Lbb/MMJ NOTES. FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER). SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"), STD. PLAN - 401 PUBLIC WORKS DEPARTMENT MANHOLE FRAME AND COVER pFo� DECEMBER 2008 0 CONSTRUCTION PERMIT SUBMITTAL CONSTRUCTION RECORD DRAWINGS �O Know what's below. Call before you dip. N0. REVISION RECESSED / LIFT POCKET o 0 o � o � o 3/4" LETTERING "SEWER" SEWER a o a o o (2) BOLT SOC. (ALLEN HEAD) 11 X 1.5 STAINLESS STEEL REF. PART00981177 O O H 1-3/}6" "-10-1/2"--i 5/1 1/4"1 12-1/2"-{ _T 1/8 2-11 I I�- ' 213/4 ---­1 1 1 CAST IRON RING AND COVER BOLT DETAIL Not to Scale 2'-0" FRAME I DIAMETER I 2'-0'° T 8" CLASS "B" ASPHALT 45- (1/8) BEND 45' (1 /8) BEND SAND OR EXPANDABLE FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES: 1. B" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS, POUR A V-O" THICK, 2'-0- SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER. �I EX. SEWER MAIN PROPERTY LINE .._.. �..._.._.._.. --SPOOL (LENGTH AS NEEDED) • ...... o 6" SEWER STUBE in I FUTURE 4" SIDE SEWER DC\---------� / ` 2"x 4" STUD MARKING POST PAINTED SEWER MAIN TEE X 6" TEE I 6" CAP J WHITE WITH THE WORD "SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND #6 WIRE Z I WRAPPED AROUND THE STUD AND 7 EXTENDED TO THE TOP OF THE STUD. COUPLING (TYP.) Q 3• L I 6'X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER � ( (EAST JORDAN IRON WORKS PRODUCT N0. 00367502 OR T ' APPROVED EQUAL, SPECIFY -SEWER- ON LID), ix 1 (SEE STD. PLAN 403.1 FOR INSTALLATION) I J JM EAGLE THREADED CLEAN -OUT ADAPTER HUB BEND AS PLUG (OR APPROVED EQUAL) REQUIRED &SAAWER�MAIN --2.OX MIN. SLOPE _3 t\\ �6" SEWER STUB `FUTURE 4" SIDE SEWER 6"%6"%6' WYE `FUTURE 6"x W REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEOURES FOR SIQF SEWER CONNECTIONS TO EXISTING SEWER MAW A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC 'TEE" USING 'STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC "TEE' USING "STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC h C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE-ORILLED. 3000 PSI MIX CONCRETE }• i pY1 OK BLOCKING ��4.5 �Mp'A�01.O al MIN SLOPE 6" TEE / HORIZONTAL 6" MIN. SEWER SEWER MAIN MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN BETWEEN 25' ANO 45' TYPICAL SIDE SEWER Nam: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER STD. PLAN -406.1 PRPUBLIC WORKS Ae �0e DEPARTMENT INSTALLATION a (SEWER MAIN TO PROPERTY LINE) ti DA PCE 2/20/17 JBS suRVEYEMITCH EVANS ACS 1112711 g CBS DESIGNED: JAMIE SCHROEDER DRAWN: PETER EVANS CHECKED: MJH BY DATE AP P R APPROVED: xxx ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAM) 1988 HORIZONTAL: NAD 1983/1991 DATUM PUBLIC WORKS 8" OR 6" CLEANOUT DEPARTMENT FOR SANITARY SEWER MAIN 0 CITY OF RENTON Planning/Building/Public Works Dept. STD. PLAN - 403.1 CONSTRUCTION RECORD DRAWING THE AS -BUILT INFORMATION SHOWN ON THIS PLAN IS PER A FIELD SURVEY PERFORMED AND DATA PROVIDED BY AXIS SURVEY & MAPPING AND/OR S-396108 RECORD ITH�RMATION CON CONTRACTOR PROVIDEDBY IN COMPLIANCE WITH CITY OF RENTON STANDARDS MEADOWVUE ROADWAY GRADING, DRAINAGE AND SANITARY SEWER IMPROVEMENTS SANITARY SEWER DETAILS 7/25/18 PAGE: DRAWING NO: C4.101 SHEET: OF: 35 43