Loading...
HomeMy WebLinkAboutP_Chain_Link_Fencing_Sections_&_Details_D-18381_190621_v1E I�; C 3 �3 L w 0 N 0 N 0 0 I o� 8 i 7 I 6 VEHICLE VERTICAL AND GATE POST HORIZONTAL RAIL SEE NOTE 7 BRACING (TYP) VEHIC�.E GATE ELEVATION 4' -8" PEDESTRIAN GATE POST SEE NOTE 8 {TYP)---� VEHICLE GATE HINGE (TYP 3 PLACES PER POST FOR VEHICLE GATES) FENCE FABRIC SEE NOTES 5 AND 6 RAIL BRACE, SEE NOTE 12 VEHICLE GATE POST CONCRETE FOOTING, SLOPE TOP TO DRAIN AWAY FROM POST, SEE SCHEDULE (T1'P ) PEDESTRIAN GATE HINGE (TYP 2 PLACES PER POST FOR PEDESTRIAN GATES) P�tiESTRIAN GATE POST CICRETE FOOTING SL=I7PE AWAY FROM POST, SEE SCHEDULE (TYP) PEDES-TRIAN -GATE ELEVATION FROM OUTSIDE FENCE. BARBED WIRE ATTACHED. SECURE TO ARM SO THAT ,��-, o IT CANNOT BE LIFTED OFF FROM OUTSIDE FENCE . � `s� -- :- o h LINE/CORNER POST SEE NOTES 9 AND 10.� MAX. SPACING BETWEEN TENSION WIRE POSTS SHALL BE 10-F FINISHED STATION �EE GRADE (REF) VI W -A V I _��./ / PLACE YARD COURSE SURFACING SO � THAT NO GAP EXISTS BETWEEN BOTTOM OF FENCE FABRIC AND TOP OF ROCK TYPICA 8 c: �pwworking�rprojectwise�9lwilli�K#ns10801�-18381_01.dgn STATION SIDE 0 I i� FINISHED STATION GRADE TOP OF BASE COURSE (REF) CORNER/LINE POST CONCRETE FOOTING, SLOPE TOP TO DRAIN AWAY FROM POST, SEE SCHEDULE (TYP.) RAIN LINK FENCE.�a�S 7 TION 5 CENTER LOCKING BAR. (LOCKED POSITION) HANDLE SHALL BE 1'-6" TO 2'-0" ABOVE GRADE AND SHALL BE FITTED WITH STOPS WHICH WILL HOLD IT IN EITHER THE LOCKED POSITION OR LIFTED POSITION. -- VENT HOLE (SEE NOTE 15) TYP AT ALL WELDED JOINTS FOR GALVANIZING PURPOSES CENTER GATE STOP, MUSHROOM TYPE MALLEABLE IRON. WELD 12" LONG STEEL PIPE TO BOTTOM AND SET IN CONCRETE FORMED WITH 10" SONO TUBE. TOP OF CONCRETE SHALL BE AT FINISHED GRADE ELEVATION. FOR PAVED DRIVEWAYS, INSTALL BEFORE ASPHALT IS PLACED. 4 3 I � I HEAVY DUTY INDUSTRIAL GATE LATCH PL 152 BY INTERNATIONAL SECURITY PRODUCTS (NOTE THAT LOCK HANGS D("""' ' GAT �o i/ a. � . � °' I � ,r � e °\� �� �� \ h I / n .I to o I� � •/ °o�_�o � o. � n e n GATE STOP DETAIL 4 NTS - 6 � 5 LATCH DETAIL NTS THE WORK SHOWN ON THIS DRAWING SHALL BE IN ACCORDANCE:: WITH...THE_FOLLOWING PSE STANDARDS 1275.1130 CONCRETE, STRUCTURAL 8350.2200 CONCRETE INSTALLATION 1025.8340 STEEL, STRUCTURAL GENERAL NOTES: 2 "EAVY DUTY GATE HINGE Y HOOVER FENCE CO. MALLEABLE IRON BUTT HINGE, ART N0. BHM-65 W/1$0° INGE ADAPTER) OR EQUAL. .AC WELD GATE HINGES 3 PLACES EACH HINGE (TYP) 5EE NOTE 4 FOR FINISH. VEHICLE GATE 1 HINGE DETAIL 2 - NTS - 3" MAX. SEE NOTE 3 VEHICLE GATE DETAIL NTS SPECIFICATIONS: AISC (LATEST). MATERIAL: STRUCTURAL STEEL, ASTM A36 (LATEST) STEEL STRUCTURAL TUBING, ASTM A501, Fy 36 ksi (LATEST) WELDS: PER AWS D-1.1 (LATEST) FINISH: GRIND SMOOTH ALL BURRS AND SHARP EDGES SURFACE COATING: HOT DIP" GALVANIZED PER ASTM A123 AND ASTM A53 (LATEST). ALL UNGALVANIZED WELDS SHALL BE CLEANED, WIRE BRUSHED AND A HOT ZINC STICK COATING APPLIED FOLLOWED BY A FINAL ZINC RICH PRIMER COATING. REFERENCE DRAPINGS & SPECIFICATIONS D-13038 ENTRANCE/ROW GATE SINGLE AND DOUBLE STANDARD DETAIL SECT 02831 CHAIN LINK FENCING � GATES, CIVIL SPECIFICATIONS CONCRETE FQOTING SCHEDULE SECTIONS 2. GATE NON -CORNER POSTS ARE TO HAVE 180° HINGES (180° ADAPTER REQUIRED). FOOTING DEPTH tSEE NOTE 13) FOOTING D"AMETER VEHICLE GATE POST GATE POSTS WITH A MAXIMUM 3" GAP BETWEEN POST AND GATE FRAME. 3'-8" MIN GATES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION AND WELDING. 18" MIN VEHICLE GATE POST W/SLATS REVIEWED 4'-0" MIN /Z� / 24" MIN CORNER/LINE POST FILE N0: 3'-6" MIN 6. 12" MIN CORNER/LINE POST W/SLATS 312' X 512 MESH S I ZE . 3'-8" MIN VEHICLE GATE POST SHALL BE 6 -INCH STANDARD (6.625 -INCH O.D.), 18" MIN PEDESTRIAN GATE POST 3'-8" MIN 18" MIN NOTE: CONCRETE FOOTING F'c = 2,500 PSI. 4 TWEEN .., .., GATE AND FINISH STATION GRADE 5 FIELD DETERMINE HEIGHT-�-, J "EAVY DUTY GATE HINGE Y HOOVER FENCE CO. MALLEABLE IRON BUTT HINGE, ART N0. BHM-4 W/180° INGE ADAPTER) OR EQUAL. .AC WELD GATE HINGES 3 PLACES EACH ,HLNGE (TYP) SEE NOTE 4' FOR FINISH. PEDESTRIAN GATE HINGE DETAIL. 3 NTS - DUCK BILL GATE KEEPER :� a o °oj �� I e. c Ia N ; :,� i .� 10"DIA POST CAP POST 2"(238" OD ) SCH 80 .PIPE FINISH GRADE GATE KEE_PER_DETAIL NTS (TO HOLD GATE OPEN) TO BE INSTALLED ON ALL VEHICLE GATES, SEE NOTE 16 FIELD LOCATE - 2 PLACES GATE AND FENCE NOTES REV NO 1 E D D 1. GATE CORNER POSTS ARE TO HAVE 90° HINGES (NO 180° ADAPTER REQUIRED). SECTIONS 2. GATE NON -CORNER POSTS ARE TO HAVE 180° HINGES (180° ADAPTER REQUIRED). 3. GATES SHALL BE FABRICATED TO MATCH THE ACTUAL DISTANCE BETWEEN SUBSTATION ENGINEERING DEPARTMENT �IDRApWING NO D -' 1 V 3 8 GATE POSTS WITH A MAXIMUM 3" GAP BETWEEN POST AND GATE FRAME. _ � 4. GATES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION AND WELDING. / / ANY FIELD WELDING SHALL BE WIRE BRUSHED CLEAN AND HOT ZINC STICK REVIEWED _ q�� COATED TO REPAIR GALVANIZING. /Z� / 5. FENCE FABRIC WITHOUT SLATS SHALL BE 9 GAUGE WIRE WOVEN INTO A FILE N0: 2" MESH SIZE. M1., 6. FENCE FABRIC WITH SLATS SHALL BE 9 GAUGE WIRE WOVEN INTO A CODE: 3 312' X 512 MESH S I ZE . 2 7. VEHICLE GATE POST SHALL BE 6 -INCH STANDARD (6.625 -INCH O.D.), WEIGHT 18.97 LB/LF OR LARGER, STEEL PIPE FOR ALL 7 -FT HIGH GATES. 8. PEDESTRIAN GATE POST SHALL BE 3.5 -INCH STANDARD (4.0 -INCH O.D., WEIGHT 9.11 LB/FT) OR LARGER STEEL PIPE FOR ALL 7 -FT HIGH GATES. 9. LINE POSTS WITH SLATS SHALL BE 3.5 -INCH STANDARD (4.0 -INCH O.D., WEIGHT 9.11 LB/LF) OR LARGER STEEL PIPE FOR ALL 7 -FT HIGH GATES. 10. LINE POSTS WITHOUT SLATS SHALL BE 2.5 -INCH STANDARD (2.875 -INCH O.D.. WEIGHT 5.79 LB/LF) OR LARGER STEEL PIPE FOR ALL 7 -FT HIGH GATES. 11. VEHICLE AND PEDESTRIAN GATE FRAMES SHALL BE 1.5 -INCH STANDARD (1.90�INCH O.D., WEIGHT 2.72 LB/LF) OR LARGER STEEL PIPE. 12. FENCE MIDDLE AND TOP RAIL AND BRACES SHALL BE 1.25 -INCH STANDARD (1.66 -INCH O.D., WEIGHT 2.27 LB/LF) OR LARGER STEEL PIPE. 13. FOOTING DEPTH IS MEASURED FROM TOP OF BASE COURSE. 14. BOLTS HOLDING LATCHES AND OTHER LOCKING HARDWARE SHALL BE PEENED TO PFI VENT REMOVAL OF NUTS. NUTS SHALL BE LOCATED ON THE INSIDE OF TH� SECURED AREA. 15. ALL PIPE JOINTS SHALL HAVE A 1/2" VENT HOLE AT BOTTOM AND TOP OF RAIL pS CLOSE TO THE WELD AS POSSIBLE. 16. ALL VEHICLE GATES SHALL RECEIVE A GATE KEEPER AS SHOWN ON FENCE PLAN, PER DETAIL 6, THIS SHEET. REVISION DESCRIPTION: WO NUMBER: C H A I N L INK F E N C I N G ADDED SECTION NOTE, REVISED NOTES 11-16 REV NO 1 E D D SECTIONS AND DETAILS DATE (M/D/Y ) PUGET � SOUND ENERGY SUBSTATION ENGINEERING DEPARTMENT �IDRApWING NO D -' 1 V 3 8 CAD _ � /d / � f / //� ENGINEER / / SHEET: 1 OF 1 REVIEWED _ q�� LQ /Z� / SCALE: NONE CLASS: SITE FILE N0: APPROVED M1., I O /2 ( / I CADD NO: D-18381 _01 . dgn CODE: 3 2 1 REV NO 1 E D D