HomeMy WebLinkAboutR-396602VAULT ACCESS Q0 1 . ACCESS RISERS ARE 48" DIAM. M.H. w/ ECCENTRIC CONE TOP SECTIONS ai AS NECESSARY (2'EC = 2' HIGH SECTION; TEC = 3' HIGH SECTION) OVER M MIN. 2' DIAM. HOLE IN VAULT PANELS OR GRADE RINGS (GR). PROVIDE LADDER OR STEPS TO BOTTOM OF VAULT PER DETAIL SHT. SD-2. O 2. PROVIDE ROUND LOCKING MANHOLE COVERS FOR ALL ACCESS RISERS. I LU O t� V Uj z ♦O V z OL 1t'�^ ♦W V O ct O W O O O TOP OF VAULT ELEV = 232.79 INSIDE TOP OF VAULT ELEV = 231.75 100 YR. W.S. ELEV = 230.95 ROUND SOLID COVER WITH LOCKING BOLTS ZVAULT ACCESS SEE NOTE NOTCH 1 "WIDE BTM ELEV = 230.25 ORIFICE ELBOW PER C.O.N. DETAIL SW-18 PIPE SUPPORTS PER C.O.N. DETAIL SW-1 8 CLEANOUT GATE: SHEAR GATE WITH CONTROL ROD, PER C.O.N. DETAIL SW-1 8 FLOOR GRATE WITH 2'X2' ACCESS DOOR 0 "xl /4" GALVANIZED METAL BARS) SEDIMENT STORAGE ELEV. = 215.7 n INSIDE BOT OF VAULT F,< ELEV. = 215.00 a. BOT OF VAULT ELEV. SEE STRUCTURAL PLANS ° 5.5' N 1' SECTION OF 1 8" PIPE ATTACHED BY 0 GASKETED BAND TO ALLOW REMOVAL. PER C.O.N. DETAIL SW-1 8 ° 4 5.5' DEPTH - TYPE II 48" CB SUMP ELEV. = 210.25 a ►"I GOLDSMITH LAND DEVELOPMENT SERVICES w 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 a T 425 462 1080 F 425 462 7719 www.goldsmi hengineering.com JOB NO. 14134 iCAP RHODY RIDGE, LLC ° 4 2' COVER MINIMUM FI _•j a 4 4 a nAE FAI 2.0' =m 4 ° 2.0' a ° a 1 8" RISER ELEV. = 230.75 VAULT WALL DESIGN BY OTHERS ORIFICE NO. 2, ELEV. = 226.45 ORIFICE DIA. = 1 .1 5" ORIFICE NOR FO. �ICE DIA. � 1?205 KNOCKOUT DIA.= WALL THICKNESS + PIPE O.D. 12" OUTLET SEE SHT. SD-3 FOR I.E. = 214.25 OUTFALL PROFILE ORIFICE NO. 1, ELEV. = 212.25 ORIFICE DIA. = 1 .1 8" SEE STRUCTURAL PLANS FOR SUMP AND FOOTING DESIGN NOTE: SEE FLOW RESTRICTOR DETAIL SW-1 8 FOR ADDITIONAL REQUIREMENTS. STORM DETENTION VAULT CONTROL STRUCTURE SCALE: 1 if= 2' 11/1/18 S • G OLd of WAS w j xw,7 z x 24597 BOA �GISTF"V- SSIONAL NO. SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. CITY OF NEWCASTLE, KING COUNTY, WASHINGTON INLET BAY o ALTERNATE o� PIPE LOCATION OUTLET BAY 3'-3" 0 O TRANSFER HOLE AND COVER LL I I I I -- L-1-r-=\----_------------ -1 L___�_LL_LJ 1_L _\L_ \1 _ \L_ I r I - Ij --0 I 1 I 1 \ - %t\ i it I I I r�---� -�-�+- -� II 1 1 F-i---�- -/ -- / L I I I I I LJF- -ice- -tJ`-- \L- \ I O j I I LL -- r-J-L - ----------- -� I STORMFILTER I I I CARTRIDGE FILTRATION BAY PLAN FRAME AND COVER (TYP OF 2) SEPARATION WALL] GRADE RINGS/RISERS (TYP OF 2) �iX INLET PIPE --------- �� ----------- ---- ---- I STEPS WEIR WALL I I I I I Io 14/ ICJ I II II II r I I II II II 3 � I I I II II II I ci� I I II II II I - -- - - �1 ---- - -�� - IL - 1 r--- --_- _- _ OUTLET PIPE STORMFILTER FLOW KIT CARTRIDGE ELEVATION Tl,e SNrn,waer Marwgeme�M StormFilter' SOLID CMER MARI® 'DRAIN' f WITH BOLT LOCKING RING AND COVER. - ATTACCII SC" TO CROSS wW 8 1' SEE NOTE 11. MET METH. SCREWS-2 PER . ._. F.FRAME • UDDER OR m'PIIPPE CCLjAMPNNlES3 OVERFLOW ELEV. PER PLANBJ"ws. SEE NOTE 10 AND 12. PIPE BIRPORIS ((ALU MM2UUWN./ �Y - 51ir AINIESSNBOLTS I g1NET PIPE INVERT ELEVAUM PER PLAN j 4. REST a" ORIFICE AS SPECIFIED PLATE BOLTED TO FLANGE OR DRILLED GAP. 4 1 54' MN. I CATCH BASIN TYPE 2 NOTES: DIAM. AS REQUIRED 1. PIPE SIZES, INVERT ELEVATIONS, ORIFICE SIZES, OVERFLOW ELEVATIONS AND SLOPES; PER PLANS. 2. OUT.Er CAPACITY: NOT LESS THAN COMBINED INLETS. 3. EXCEPT AS SHOWN OR NOTED, UNITS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS FOR CATCH BASIN TYPE 2, 54' MIN. DIAM. 4. PIPE SUPPORTS AND RESTRICTOR SHALL BE OF SAME MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY 5/8' DIAM. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2' IN WALL. S. THE RESTRICTOR SHALL BE FABRICTED FROM .061 ALUMINUM, PVC, CPE, OR HDPE PIPE PER THESE ENGINEERING STANDARDS. 6. OUTLET SWILL BE CONNECTED TO CULVERT OR SEWER PIPE WITH SUITABLE C CONCRETE PIPE. OUPLER OR GROUTED INTO THE BELL OF 7. THE VERTICAL RISER STEM OF THE RESTICTOR SHALL BE THE SAME DIAM. AS THE HORIZONTAL OUTLET PIPE, WITH AN W MIN. DIAM. 8. FRAME AND LADDER OR STEPS OFFSET SO THAT: A. SHEAR GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS CLEAR OF RISER AND SHEAR GATE C. FRAME IS CLEAR OF CURB. 9. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4'. 10. MULTI -ORIFICE ELBOWS MAY BE LOCATED AS SHOWN OR ALL ON ONE SIDE OF RISER TO ASSURE LADDER CLEARANCE 11. SHEAR GATE HANDLE SHALL BE ATTACHED TO LADDER/ STEP LOCATED WITHIN 24" ACCESS SECTION. 12. IF NOTCHED WIER IS USED IN LIEU OF ELBOW, BAFFLE SHALL NOT OBSTRUCT ACCESS TO THE STRUCTURE SURVEYED: LN DESIGNED: BPF, SP DRAWN: SP CHECKED: BPF, KJG REVISION BY DATE APPR APPROVED: KJ G STEPS OFFSET. BEE NOTE 8. 4 - 9wx1*x126 GA 12' GALV. STRIPS TACK WELD TO WIRE MESH. SHEAR LATE L GALVI 8ME� SOLID 12 GL CALV.J/ TACK WELD WIRE MESH BOTTOM PLATE To BoT1011 PLATE 36' MIN. DIA. rwE FLOW CONTROL SCREEN INVERT ELEV. PER PIA! Ta COu� - ,zI PLATE WITH ORIFICE AS SPECIFIED, BOLTED 70 FLANGE OR DRILLED CAP ELBOW DETAIL CITY OF NEWCASTLE FLOW RESTRICTOR TEE TYPE APPROVED: DWG. NO. ROGER KUYKENDALL, P.E. 8/1/2000 SW-18 BY CITY DATE NOTE: APPROVED FOR CONSTRUCTION 1) WORK SHOWN ON THIS PLAN IS LOCATED BY: DATE: IN THE CITY OF NEWCASTLE. IT IS PART OF CITY OF NEWCASTLE NEWCASTLE PERMIT ERP1 7-009. THIS PLAN IS INCLUDED FOR REFERENCE ONLY. PLANS THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT APPROVED BY THE CITY OF NEWCASTLE TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD SHOULD BE USED FOR IMPROVEMENTS IN CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO THE CITY OF NEWCASTLE. THEIR ACCURACY OR OMISSIONS. STORMFILTER DESIGN NOTES • THE 8' x 1 V PEAK DIVERSION STORMFILTER TREATMENT CAPACITY VARIES BY CARTRIDGE COUNT AND LOCALLY APPROVED SURFACE AREA SPECIFIC FLOW RATE. PEAK CONVEYANCE CAPACITY TO BE DETERMINED BY ENGINEER OF RECORD. • THE PEAK DIVERSION STORMFILTER IS AVAILABLE IN A LEFT INLET (AS SHOWN) OR RIGHT INLET CONFIGURATION. • ALL PARTS AND INTERNAL ASSEMBLY PROVIDED BY CONTECH UNLESS OTHERWISE NOTED. CARTRIDGE SELECTION CARTRIDGE HEIGHT 27" 18" LOW DROP RECOMMENDED HYDRAULIC DROP (H) 3.05' 2.3' 1.8' HEIGHT OF WEIR (W) 3.00' 2.25' 1.75' SPECIFIC FLOW RATE (gpm/sf) 2 gpm/sf 1.67* gpm/sf 1 gpm/sf 2 gpm/sf 1.67* gpm/sf 1 gpm/sf 2 gpm/sf 1.67*gpm/sf 1 gpm/sf CARTRIDGE FLOW RATE (gpm) 22.5 1 18.79 1 11.25 15 1 12.53 1 7.5 10 8.35 5 1.67 gpm/sf SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORB ° (PSORB) MEDIA ONLY FRAME AND COVER (DIAMETER VARIES) N.T.S. SITE SPECIFIC DATA REQUIREMENTS STRUCTUREID SD#5 WATER QUALITY FLOW RATE (cfs) 0.41 PEAK FLOW RATE (cfs) 3.07 RETURN PERIOD OF PEAK FLOW (yrs) 100 CARTRIDGE HEIGHT (27", 18", LOW DROP(LD)) 27" NUMBER OF CARTRIDGES REQUIRED 17 CARTRIDGE FLOW RATE 111.3 GPM MEDIA TYPE (PERLITE, ZPG, PSORB) ZPG PIPE DATA: I.E. MATERIAL DIAMETER INLET PIPE 246.50 12" OUTLET PIPE 243.45 12" UPSTREAM RIM ELEVATION 250.00 DOWNSTREAM RIM ELEVATION 250.00 ANTI -FLOTATION BALLAST I WIDTH F HEIGHT NOTES/SPECIAL REQUIREMENTS: PER ENGINEER OF RECORD PERFORMANCE SPECIFICATION FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. SPECIFIC FLOW RATE SHALL BE 2 GPM/SF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPM/CF OF MEDIA (MAXIMUM). GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY. 3. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH REPRESENTATIVE. www.contechES.com 4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. 5. STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0' - SAND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. INSTALLATION NOTES A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE (LIFTING CLUTCHES PROVIDED). C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT PIPES. MATCH OUTLET PIPE INVERT WITH OUTLET BAY FLOOR. E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. F. CONTRACTOR TO REMOVE THE TRANSFER HOLE COVER WHEN THE SYSTEM IS BROUGHT ONLINE. C►NTECH• THE STORMWATER MANAGEMENT STORMFILTER ENGINEERED SOLUTIONS LLC $' x 1 V PEAK DIVERSION STORMFILTER www.contechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 STANDARD DETAIL 800-338-1122 513-645-7000 513-645-7993 FAX AN Know what's below. Call before you dig. SCALE: VERTICAL: NAVD 1988 VARIES HORIZONTAL: NAD 1983/1991 CITY OF %R RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept IF NOT ONE INCH SCALE ACCORDINGLY �a z O r� V W CO`] V O R-396602 W IN COMPLIANCE WITH CITY OF RENTON STANDARDS W DEVELOPMENT ENGINEERING Justin Johnson 02/11/2019 O 0 DATE: RHODODENDRON RIDGE W ERP PLAN SET FIELDBOOK: 1977 O PAGE: 27 / / Q DRAWING NO: O DETENTION VAULT CONTROL STRUCTURE DETAIL SD-2 = SHEET: OF: 2 6