Loading...
HomeMy WebLinkAboutR-396605Y N m 3 0 FRAME AND VANED GRATE 6" OR 12" ONE 9.3 BAR HOOP FOR 6• HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT RECTANGULAR ADJUSTMENT SECTION PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" CPSSP* 12' (STD. SPEC. 9-0520) SOLID WALL PVC 15' (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15" (STD. SPEC. 9-05.12(2)) iF CORRUGATED POLYETHYLENE STORM SEWER PIPE lgfbE �eJ NOTES pN A � to the rebar shown in the PRECAST BASE SECTION, fibers alternatives 1. As acceptable d a according to the Standard Specifications), or (placed wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. #3 BAR EACH CORNER _ #3 BAR EACH SIDE #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR EACH CORNER 18" MIN #3 BAR HOOP 2. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4. The frame and grate must be installed with the flange down. 5. The Precast Base Section may have a rounded floor, and the walls may Y be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the precast base section. 7. All pickup holes shall be routed full after the basin has been laced. P P 9 p 8. All grade rings and castings shall be set in mortar in accordance with Standard Specification 9-04.3. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION STD. PLAN - 200.00 PUBLIC WORKS CATCH BASIN TYPE 1 DEPARTMENT MARCH 2O08 24" a N N z �a Z g W Co 1 m tt BOLT -DOWN SLOT -SEE DETAIL AND NOTE 1 J 40 A J O�OOOp O�a�aQO 0�0�040Q QOOQQ�Q�Q O O O O O B TOP 4 3/4" L T =-7-,'R -SEE NOTE 2 SECTION O 5" 3 1/2" 1/2 ,3/4" 5/8 3/4" 4 �-� -- 314" DIAM. HOLE 1 1/4" 1 1/2• 10 DIAM. HANDLE SECTION O BOLT -DOWN SLOT DETAIL SEE NOTE 1 SECTION OB NOTES 1 Provide two slots in the cover that are vertically aligned with the holes in the frame.Location of bolt -down slots varies among different manufacturers. 2. Alternative reinforcing designs are acceptable in lieu of the rib design. 3. Refer to Standard Specification 9-05.15(2) for additional requirements 4. For Frame details, see City of Renton Standard Plan 204.00. ISOMETRIC PUBLIC WORKS RECTANGULAR SOLID STD. PLAN - 204.10 DEPARTMENT METAL COVER MARCH 2O08 GOLDSMITH LAND DEVELOPMENT SERVICES w 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 a T 425 462 1080 F 425 462 7719 www.goldsmithengineering.com JOB NO. 14134 iCAP RHODY RIDGE, LLC 11/1/18 1 • Gold of WAS w j 14,7 1 z x 24597 �04� GISTEg�'9 SSIONAL St O 0 6 0 \ CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) HANDHOLD �g5 Z RECTANGULAR ADJUSTMENT SECTION 2 OR CIRCULAR ADJUSTMENT SECTION m v GROUT, TYPICAL (SEE NOTE 5) FLAT SLAB TOP 46', 54", 60', 72', 84" OR 96" MORTAR (TYP.) STEPS ER LADDER 'ILLET N REINFORCING STEEL (TYP-) \ b 12' GRAVEL BACKFILL FOR . , PIPE ZONE BEDDING e• SEPARATE BASE INTEGRAL BASE CAST -IN -PLACE PRECAST WITH RISER WRING 1r GRAVEL BACKFILL FOR 8T - PIPE ZONE BEDDING J� SEPARATE BASE PRECAST SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS BASE REINFORCING STEEL in2fft IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE 48' 4• 6" 36" 8" 0.23 0.15 54' 4.5" 8" 42• 8• 0.19 0.19 so, 5" 8" 48" 8" 0.25 0.25 72" e" 8" 60" 12" 0.35 0.24 84• 1 8" 1 12" 1 72" 1 12" 0.39 1 0.29 9e• 1 8" 12" 1 84" 1 IT 0.39 0.29 NOTES I. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning. 3. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 5 All d d f h II b t' ' rd •th PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER BASIN DIAMETER CONCRETE ALL METAL CPSSP O SOLID WALL Pvc 20 PROFILE WALL Pvc p 48• 24' M. 24" 27' 30' 54" 30" 36" 30" 27" 36" 60" 36" 42" N. 3W 42' 72" 42' 54' 42" 36• 48" 84" 54" 60" 54" 36' 48" N' Bo" 72" 60" 36' 48' gra a nngS, users, an Cas ngS S a e Se In m0 rta r In aCCO ance WI Standard Specification 9-04.3. 8 (Bid. Spec. 9-0. Corrugated 511)) Polyethylene Storm 9-0 Sewer Pipe (Std. Spec. (Sid. Spec. 9-05.12(2)) Y PUBLIC WORKS CATCH BASIN TYPE 2 PLAN - 201.00 DEPARTMENT �N tp MARCH 2O08 �''•Illl>•�I�Ibr. 1"�44, 11r [13mm] LETTERING BOLTHOLES - 3 PLCS EQUALLY SPACED 120" APART ON 231116" (586mm) DIA B.C. q 3 RENTON AHEAD OF THE CURVE DRAIN (1)1" (25mm) DIA PICKHOLE ® 1 1/4• [32mml LETTERING PLAN VIEW 25• DIA. [635mm] 1' r [25mm] 3/4' +L1li [19mm] 9 3/a 2112 -# Immrn] [64mm1 TYP COVER SECTION VIEW 26 1/2" DIA [673mm] 25 1/4" DIA [641mm] 1 1/18" "4. (Bmm) DIA [27mm] NEOPRENE GASKET 11 1T [752mm8"] J 5/8" 23 3/8" DIA CL OPEN [16mm] [594mm] 27 5/16" DIA [694mm] 34 1/8" DIA [867mm] FRAME SECTION VIEW COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 58r'-11 x 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4" 1 1I18" [Bmm] _ [27mm] 1/8• 1T [3mm] 1/8' [R3mm] GASKET GROOVE DETAIL NOTES ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRON WORKS INC. No. 3717C1 OR APPROVED EQUAL. aj PUBLIC WORKS STORM ROUND FRAME AND COVER STD. PLAN - 204.50 �N CCU DEPARTMENT MARCH 2O08 NO. REVISION DF NEWCASTLE, KING COUNTY, WASHINGTON 0 FRAME AND VANED GRATE CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE GROUTED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION. BASE SECTION NOTES SEE NOTE 4 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO GROUT IN PLACE IN ACCORDANCE WITH APWA STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT, 4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR j2 BOND. 5, ADJUSTMENT SECTION SHALL BE GROUTED WATERTIGHT TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH NONSHRINK GROUT 6. GROUTING BETWEEN ADJUSTMENT SECTION SHALL BE WATER TIGHT. 7. GROUT IS TO BE NON -SHRINK TYPE GROUT MEETING THE REQUIREMENTS OF ASTM 157 PER APWA STANDARD SPECIFICATION 9-20.3 FOR MAXIMUM PERCENT DRY SHRINKAGE. THE MINIMUM COMPRESSIVE STRENGTH SHALL BE 4,000 PSI AT 7 DAY PER APWA STANDARD SPECIFICATION 9-20.3 8. PICK I LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. PUBLIC WORKS CATCsA CASUM INSTALLATION STD. PLAN - 202.00 DEPARTMENT MARCH 2O08 #6 BARS @ 7" SPACING 24" DIAM., 48" DIAM. OR 54" DIAM. HOLE 2" (TYP.) r 12 1' MIN. 1/2'MAX. 8W* or 86" FLAT SLAB TOP A�i #5 BARS @ 6" SPACING 20" x 24", 24" DIAM., 48" DIAM. OR 54" DIAM. HOLE 2" (4411"MIN. TYPICAL ORIENTATION J- FOR ACCESS AND STEPS m 2 1/2" MAX. 72" FLAT SLAB TOP 2� #4 BARS @ 6" SPACING a 20' x 24" OR 24" DIAM. HOLE 2"(TYP.) ''• -�'-. t' 48" MIN. V MIN. 2112" MAX. ECCENTRIC CONE SECTION 48", 54", or 60" FLAT SLAB TOP 12" (TYP.) M a 6" to 12" PREFABRICATED LADDER 12" MIN. �s STEP 6" OR 12" <�CINE #3 BAR HOOP ONE #3 BAR HOOP FOR 6" 0 4" S• TWO #3 BAR HOOPS FOR 12" CIRCULAR ADJUSTMENT SECTION RECTANGULAR ADJUSTMENT SECTION 1.0 As an acceptable alternative to rebar, wire mesh having a minimum area of 0.12 square inches per foot may be used for adjustment sections. PUBLIC WORKS MISCELLANEOUS DETAILS FOR STD. PLAN - 204.80 DEPARTMENT DRAINAGE STRUCTURES "A�N,fp MARCH 2O08 SURVEYED: LN DESIGNED: BPF, SP DRAWN: SP CHECKED: BPF, KJG BY DATE APPR APPROVED: KJ G SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 29114" N r BOLT -DOWN HOLE (TYP.) 5W -11 NC, SEE DETAIL & NOTE 2 O APPROVED FOR CONSTRUCTION BY: DATE: - CITY OF NEWCASTLE THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO THEIR ACCURACY OR OMISSIONS. NOTES TOP 1• This frame is designed to accommodate 20" x 24" grates or covers 2. Provide two holes in the frame that are vertically aligned with t he grate or cover slots. Tap each hole to accept 241/4' a 5/8' - 11 NC x 2" alien head cap screw. Location of bolt down holes varies among different e manufacturers. 3. Refer to Standard Specification 9-05.15(2) for additional 4. requirements. SECTION A RECESSED ALLEN HEAD CAP SCREW 718" 1/8. 5/8"-11 NCx2" II�{I 3/4" GRATE a � 1 5fir 2 1/2' SECTION BOLT -DOWN DETAIL DETAIL O SEE NOTE p�PUBLIC WORKS RECTANGULAR FRAME $ DEPARTMENT N'C S 9 I, 12 Smooth Coupling Band for Smooth Pipe material to be 3" ASTM A plate galvanized I I after fabrics ion per ASTM A 123 r 4.1 slots to be all holes 119/sz x• a -Y4" diam. �� 1 7" coupling bend 4" STD. PLAN - 204.00 MARCH 2O08 Pipe stakes I LJ 049 On u� u^ r-1 �a 4z 12" I � O Plate Detail coupling band NOTE: ♦ ` 1. The smooth coupling band shall be used in v 1„ collar (2" pipe) combination with concrete pipe. UJ 2. Concrete pipe without bell and spigot shall not be installed on grades in excess of 20%. weld weld 3. The first anchor shall be installed on the first Z plate (see detail) section of the lower end of the pipe and remaining anchors evenly spaced throughout the installation. material to be ASTM O 4. If the pipe being installed has a manhole or A 36 galvanized after p catch basin on the lower end of the pipe, the 1 )" x 6' pipe stakes fabrication per ASTM p each side of culvert A 153 first pipe anchor may be eliminated. v 5. When CMP is used, the anchors may be attached to the coupling bands used tojoin flatten to point the pipe as long as the specified spacing is Anchor Assembly not exceeded. Corrugated Metal Pipe 6. All pipe anchors shall be securely installed before backfilling around the pipe. R-396605 � PUBLIC WORKS `�•`•` ` DETAILS FOR COUPLING BANDS STD. PLAN - 221.20 MARCH 2O08 DEPARTMENT "AWN FOR CORRUGATED METAL PIPES t 0 `/ W IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 DEVELOPMENT ENGINEERING 1• SURFACE WATER UTILITY Justin Johnson 02/11/2019 rstraka 02/11/2019 Z CITY OF RHODODENDRON RIDGE DATE 11/1/18 Q RENTON ERP PLAN SET 27 Y FIELDBOOK: 1 9 7 7 Y PAGE: 7 / / Q DRAWING NO: O Planning/Building/Public Works Dept. STORM DRAINAGE DETAILS D-7 SHEET: OF: 2 6