HomeMy WebLinkAboutR-396606SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. CITY OF NEWCASTLE. KING COUNTY. WASHINGTON 0) rrn O W I- limits of pipe compaction grave for pipe „e.­�y A. Metal and Concrete limits of pipe Dmpaction o" 0.15 O.D. min. 35 O.D. min. specified 3' max •� 0.15 rise min. limits of pipe compaction 65 rise min. gravel backill gravel backfill for for pipe betltling foundations when specified B. Pipe - Arch Installation Rigid Pipe NOTES: 1. Pipe compaction limits shown on this plan are for pipe construction in an embankment. For pipe construction in a trench, the horizontal limits of the pipe compaction zone shall be the walls of the trench. 2. All steel and aluminum pipe and pipe -arches shall be installed in accordance with design A. 3. Concrete pipe with elliptical reinforcement shall be installed in accordance with design A. 4. Concrete pipe, plain or with circular reinforcement, shall be installed with design A. 5. O.D. is equal to the outside diameter of a pipe or the outside span of pipe -arch. The dimensions shown as O.D. with 3' maximum shall be O.D. until O.D. equals 3; at which point T shall be used. VFW for diameters 12" through 42" and spans through 50". 2'-0" for diameters greater than 42" and spans greater than 50". W (see note 4) limit of pipe zone bedding material b for flexible pipe (see note 6) m O.D. foundafion level " A = 4" min. 27" I.D. and under 6" min., over 27" I.D. Bedding for Flexible Pipe Flexible Pipe NOTES: 1. Provide uniform support under barrels. 2. Hand tamp under haunches. 3. Compact bedding material to 95% max. density; directly over pipe, hand tamp only. 4. See "Excavation and Preparation of Trench" in sanitary sewers section of the standard WSDOT/APWA specifications for trench width "W" and trenching Options. The pipe zone will be the actual trench width. The minimum concrete width shall be 11 I.D. = 18". 5. Trench backfill shall conform to "Backfilling Sewer Trenches" in the sanitary sewers section of the WSDOT/APWA standard specifications, except that rocks or lumps larger than 1" per foot of pipe diameter shall not be used in the backfill material. 6. See "Bedding Material for Flexible Pipe" in aggregates section of the WSDOT/APWA standard speciflceflons for the material specifications. ®Backfill material placed in 0.5' loose layers and compacted to 95% maximum density. Method B or C compaction (WSDOT/APWA) standard specifications.) Pipe Size Min. dist. between barrels circular pipe conic., LCPE, CMP (diameter) 12" to 24" 12" 30" to 96" diam. / 2 102" to 180" 48" pipe - arch metal only (span) 18" to 36" 12" 43" to 142" span / 3 148" to 199" 48" ti�Y o STD. PLAN - 220.00 PUBLIC WORKS PIPE COMPACTION DEPARTMENT DESIGN AND BACKFILL MARCH 2O08 GOLDSMITH LAND DEVELOPMENT SERVICES w 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 a T 425 462 1080 F 425 462 7719 www.goldsmithengineering.com JOB NO. 14134 iCAP RHODY RIDGE, LLC 11/1/18 1 " G OLd OF WAS w j .14 1 z x 24597 BOA �GIS'TEg�'9 SSIONAL ECG STANDARD STRENGTH CATCH BASIN 1. CONDITION OF USE 1.1. SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCHBASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 1.2. MAY BE USED ANYWHERE AT THE APPLICANT'S DISCRETION TO PROTECT DRAINAGE SYSTEM. 1.3. THE CONTRIBUTING DRAINAGE AREA MOST NOT BE LARGER THAN 1 ACRE. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. FILTER FABRIC IS ONLY ALLOWED WERE PONDING WILL NOT BE A TRAFFIC CONCERN AND WHERE SLOPE EROSION WILL NOT RESULT IF THE CURB IS OVERTOPPED BY PONDED WATER. 2.2. THE PLACEMENT OF A FILTER FABRIC UNDER GRATES IS GENERALLY PROHIBITED AND THE USE OF FILTER FABRIC OVER GRATES IS STRICTLY LIMITED AND DISCOURAGED. 3. MAINTENANCE STANDARDS 3.1. ANY ACCUMULATED SEDIMENT ON OR AROUND INLET PROTECTION SHALL BE REMOVED IMMEDIATELY. SEDIMENT SHALL NOT BE REMOVED WITH WATER AND ALL SEDIMENT MUST BE DISPOSED OF AS FILL ON SITE OR HAULED OFF SITE. TY PUBLIC WORKS DEPARTMENT FILTER FABRIC PROTECTION STD. PLAN - 216.20 MARCH 2O08 JOINTS IN FILTER FABRIC SHALL BE SPLICED a AT POSTS. USE STAPLES, WIRE RINGS, OR 2"x2" BY 14 Ga. WIRE OR y EQUIVALENT TO ATTACH FABRIC TO POSTS. EQUIVALENT, IF STANDARD z STRENGTH FABRIC USED --- :�� 7 FILTER FABRIC o mnn. POST SPACING MAY BE INCREASED TO V E WIRE BACKING IS USED MINIMUM 4"x4" TRENCH BACKFILL TRENCH WITH NATIVE SOIL 27r4" WOOD POSTS, STEEL FENCE / POSTS, REBAR, OR EQUIVALENT 2 NOTES 1. CONDITION OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. 30-1005IEVESIZE (0.60-Q15MM)FORSILTFILM A05 (ASTM 34751) 50-10051EVE SIZE 0.30-015MM FOR OTHER FABRICS WATER PERMITTIVITY ASTM D491 M02SECA-1 MINIMUM GRAB TENSILE STRENCHr (ASTM D4532) 180 LBS. MI N. FOR EXTRA STRENGH FABRIC 100 LBS. MI N. FOR STANDARD STRENGHT FABRIC GRAB TENSI LE ELONGATION ASTM D4632 30%MAX. ULTRAVIOLATE RESISTANCE(ASTM D4355) 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1 V 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE S WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. 3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. T IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. 3A SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTE)CTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. STD. PLAN - 214.00 PUBLIC WORKS SILT FENCE DEPARTMENT MARCH 2O08 NO. REVISION DRAINAGE GRATE GRATEFRAME v � SEDIMENTAND DEBRIS o• D FILTERED( WATER r RIM kt> OVERFLOW BYPASS BELOW INLET GRATE DEVICE 4 � SECTION VIEW DRAINAGE GRATE RECTANGULAR GRATE SHOWN un BELOW INLET GRATE DEVICE RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) ISOMETRIC VIEW NOTES 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service. 2. The BIGD shall have a built-in high -flow relief system (overflow bypass). 3. The retrieval system must allow removal of the BIGD without spilling the collected material. 4. Perform maintenance in accordance with Standard Specification 8-01.3(15). ��Y STD. PLAN - 216.30 PUBLIC WORKS CATCH BASIN FILTER '' DEPARTMENT N2 MARCH 2O08 3 m SILT FENCE 3 TOP OF FABRIC ` BELT ' TOP 8" FLOW 1 100% COMPACTION EACH SIDE DIAGONAL ATTACHMENT DOUBLES STRENGTH NOTES: 1. POST SPACING: T MAX. ON OPEN RUNS 4' MAX. ON POOLING AREAS. 2. POST DEPTH: AS MUCH BELOW GROUND AS FABRIC ABOVE GROUND. 3. PONDING HEIGHT MAX. 24" ATTACH FABRIC TO UPSTREAM SIDE OF POST. 4. DRIVE OVER EACH SIDE OF SILT FENCE 2 TO 4 TIMES WITH DEVICE EXERTING 60 P.S.I. OR GREATER. 5. NO MORE THAN 24" OF A 36" FABRIC S ALLOWED ABOVE GROUND. 6. VIBRATORY PLOW IS NOT ACCEPTABLE BECAUSE OF HORIZONTAL COMPACTION. ­Z3OPERATION HORIZONTAL CHISEL POINT (76mm WIDTH) ATTACHMENT DETAILS: 1. GATHER FABRIC AT POSTS, IF NEEDED. 2. UTILIZE THREE TIES PER POST, ALL WITHIN TOP 8" OF FABRIC. 3. POSITION EACH TIE DIAGONALLY, PUNCTURING HOLES VERTICALLY A MINIMUM OF V APART. 4. HANG EACH TIE ON A POST NIPPLE AND TIGHTEN SECURELY. USE CABLE TIES (50 LBS) OF SOFT WIRE. ROLL OF SILT FENCE 200-300mm STD. PLAN - 214.10 PUBLIC WORKS SILT FENCE INSTALLATION DEPARTMENT BY SLICING MARCH 2O08 SURVEYED: LN DESIGNED: BPF, SP DRAWN: SP CHECKED: BPF, KJG BY DATE APPR APPROVED: KJ G SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM SPECIAL NOTE: IN THE EVENT TRANSVERSE PATCHES EXIST WITHIN THE AFFECTED STREET, THE LENGTH OF THE PATCH SHALL BE EXTENDED TO INCLUDE ANY EXISTING PATCH WITHIN 10 FEET OF THE EDGE OF THE PATCH REQUIRED FOR THE NEW CROSSING AND ANY SUBSEQUENT PATCH EDGE WITHIN 10 FEET OF THE EDGE OF THE SECOND PATCH AND SO ON UP TO A TOTAL OF 300 FEET. APPROVED FOR CONSTRUCTION BY: DATE: - CITY OF NEWCASTLE THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO THEIR ACCURACY OR OMISSIONS. 1' 1' VARIES 1' 1' MIN I MIN MIN I MIN T_V ,. �v .•.I:_ .��:: L r� I i .Ii �•, TRAFFIC FLOW •t , I' i I 2" HMA I #•.'. 2" TO 8" HMA I. 4 I 6.5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES: 6.5' MIN. MIN j MIN VARIES MIN I MIN FACE OF GUTTER OR EDGE OF PAVEMENT CENTER LINE OR LANE LINE DEPTH OF EXISTING PAVEMENT ! 2" SAWCUT AND REMOVE OR PLANE, SEAL WITH 2" - 6" MIN. HMA (SEE NOTE 2) AR-4000W I . (EACH SIDE) 6" CRUSHED SURFACING TOP COURSE (CSTC) 2" HMA PER WSDOT STANDARD SPE� FICATIONS, COMPACTED TO 95X MODIFIED PROCTOR, SAWCUT AFTER BACKFILL \-CSTC, (EACH SIDE) BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19). GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO 95% MODIFIED PROCTOR. WIDTH OF TRENCH AS REQUIRED BY SIZE OF PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF NEEDED, SHALL MEET THE REQUIREMENTS OF WSDOT PIPE ZONE BEDDING. MATERIAL- SEE STANDARD STANDARD SPECIFICATION 7-08.3(1)B PLAN 110.1. TRENCH WIDTH FOR NOTES, SEE STANDARD PLAN 110.1 TYPICAL TRANSVERSE PATCH FOR STD" PLAN - 110 is PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID PPFz ED DEPARTMENT PAVEMENT WITH OVERLAY 77 �8u -ram AN Know what's below. Call before you dig. AwtbL CITY OF RENTON Planning/Building/Public Works Dept. 1 u� �a z 0 W Z Z O V Z R-396606co ° IN COMPLIANCE WITH CITY OF RENTON STANDARDS W 0 DEVELOPMENT ENGINEERING SURFACE WATER UTILITY Justin Johnson 02/11 /2019 rstraka 02/11 /2019 Z O 0 DATE: W RHODODENDRON RIDGE 11/1/18 0 PAGE: � 7 / / ERP PLAN SET OOK 1777 O PAGE: Q DRAWING NO: O STORM DRAINAGE DETAILS D-8 _ SHEET: OF: 2 6