HomeMy WebLinkAboutR-396606SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M.
CITY OF NEWCASTLE. KING COUNTY. WASHINGTON
0)
rrn
O
W
I-
limits of pipe
compaction
grave
for pipe „e.�y
A. Metal and Concrete
limits of pipe
Dmpaction
o"
0.15 O.D. min.
35 O.D. min.
specified
3' max
•� 0.15 rise min.
limits of pipe
compaction 65 rise min.
gravel backill gravel backfill for
for pipe betltling foundations when specified
B. Pipe - Arch Installation
Rigid Pipe NOTES:
1. Pipe compaction limits shown on this plan are for pipe
construction in an embankment. For pipe construction
in a trench, the horizontal limits of the pipe compaction
zone shall be the walls of the trench.
2. All steel and aluminum pipe and pipe -arches shall be
installed in accordance with design A.
3. Concrete pipe with elliptical reinforcement shall be
installed in accordance with design A.
4. Concrete pipe, plain or with circular reinforcement, shall
be installed with design A.
5. O.D. is equal to the outside diameter of a pipe or the
outside span of pipe -arch. The dimensions shown as
O.D. with 3' maximum shall be O.D. until O.D. equals
3; at which point T shall be used.
VFW for diameters 12" through 42" and spans through
50". 2'-0" for diameters greater than 42" and spans
greater than 50".
W (see note 4)
limit of pipe zone
bedding
material b
for flexible
pipe (see
note 6)
m O.D.
foundafion
level
" A = 4" min. 27" I.D. and under
6" min., over 27" I.D.
Bedding for Flexible Pipe
Flexible Pipe NOTES:
1. Provide uniform support under barrels.
2. Hand tamp under haunches.
3. Compact bedding material to 95% max. density; directly
over pipe, hand tamp only.
4. See "Excavation and Preparation of Trench" in sanitary
sewers section of the standard WSDOT/APWA
specifications for trench width "W" and trenching
Options. The pipe zone will be the actual trench width.
The minimum concrete width shall be 11 I.D. = 18".
5. Trench backfill shall conform to "Backfilling Sewer
Trenches" in the sanitary sewers section of the
WSDOT/APWA standard specifications, except that
rocks or lumps larger than 1" per foot of pipe diameter
shall not be used in the backfill material.
6. See "Bedding Material for Flexible Pipe" in aggregates
section of the WSDOT/APWA standard speciflceflons
for the material specifications.
®Backfill material placed in 0.5' loose layers and
compacted to 95% maximum density.
Method B or C compaction (WSDOT/APWA)
standard specifications.)
Pipe
Size
Min. dist.
between
barrels
circular pipe
conic., LCPE, CMP
(diameter)
12" to 24"
12"
30" to 96"
diam. / 2
102" to 180"
48"
pipe - arch
metal only
(span)
18" to 36"
12"
43" to 142"
span / 3
148" to 199"
48"
ti�Y o STD. PLAN - 220.00
PUBLIC WORKS PIPE COMPACTION
DEPARTMENT DESIGN AND BACKFILL MARCH 2O08
GOLDSMITH
LAND DEVELOPMENT SERVICES
w 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009
a T 425 462 1080 F 425 462 7719 www.goldsmithengineering.com
JOB NO. 14134 iCAP RHODY RIDGE, LLC
11/1/18
1 " G OLd
OF WAS
w j
.14 1 z x
24597
BOA �GIS'TEg�'9
SSIONAL ECG
STANDARD STRENGTH
CATCH BASIN
1. CONDITION OF USE
1.1. SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS
THE RUNOFF THAT ENTERS THE CATCHBASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP.
1.2. MAY BE USED ANYWHERE AT THE APPLICANT'S DISCRETION TO PROTECT DRAINAGE SYSTEM.
1.3. THE CONTRIBUTING DRAINAGE AREA MOST NOT BE LARGER THAN 1 ACRE.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. FILTER FABRIC IS ONLY ALLOWED WERE PONDING WILL NOT BE A TRAFFIC CONCERN AND WHERE SLOPE EROSION WILL NOT RESULT IF THE
CURB IS OVERTOPPED BY PONDED WATER.
2.2. THE PLACEMENT OF A FILTER FABRIC UNDER GRATES IS GENERALLY PROHIBITED AND THE USE OF FILTER FABRIC OVER GRATES IS STRICTLY
LIMITED AND DISCOURAGED.
3. MAINTENANCE STANDARDS
3.1. ANY ACCUMULATED SEDIMENT ON OR AROUND INLET PROTECTION SHALL BE REMOVED IMMEDIATELY. SEDIMENT SHALL NOT BE REMOVED
WITH WATER AND ALL SEDIMENT MUST BE DISPOSED OF AS FILL ON SITE OR HAULED OFF SITE.
TY
PUBLIC WORKS
DEPARTMENT
FILTER FABRIC PROTECTION
STD. PLAN
- 216.20
MARCH
2O08
JOINTS IN FILTER FABRIC SHALL BE SPLICED
a
AT POSTS. USE STAPLES, WIRE RINGS, OR
2"x2" BY 14 Ga. WIRE OR
y
EQUIVALENT TO ATTACH FABRIC TO POSTS.
EQUIVALENT, IF STANDARD
z
STRENGTH FABRIC USED
---
:��
7
FILTER FABRIC
o mnn.
POST SPACING MAY BE INCREASED
TO V E WIRE BACKING IS USED
MINIMUM 4"x4" TRENCH
BACKFILL TRENCH WITH
NATIVE SOIL
27r4" WOOD POSTS, STEEL FENCE /
POSTS, REBAR, OR EQUIVALENT
2
NOTES
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
AVAILABLE ON SITE.
30-1005IEVESIZE (0.60-Q15MM)FORSILTFILM
A05 (ASTM 34751)
50-10051EVE SIZE 0.30-015MM FOR OTHER FABRICS
WATER PERMITTIVITY ASTM D491
M02SECA-1 MINIMUM
GRAB TENSILE STRENCHr (ASTM D4532)
180 LBS. MI N. FOR EXTRA STRENGH FABRIC
100 LBS. MI N. FOR STANDARD STRENGHT FABRIC
GRAB TENSI LE ELONGATION ASTM D4632
30%MAX.
ULTRAVIOLATE RESISTANCE(ASTM D4355)
70%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1 V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
S WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. T IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3A SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTE)CTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
STD. PLAN - 214.00
PUBLIC WORKS SILT FENCE
DEPARTMENT
MARCH 2O08
NO.
REVISION
DRAINAGE GRATE
GRATEFRAME
v �
SEDIMENTAND DEBRIS
o•
D
FILTERED(
WATER
r
RIM
kt>
OVERFLOW BYPASS
BELOW INLET GRATE DEVICE
4 �
SECTION VIEW
DRAINAGE GRATE
RECTANGULAR GRATE SHOWN
un
BELOW INLET GRATE DEVICE
RETRIEVAL SYSTEM (TYP.)
OVERFLOW BYPASS (TYP.)
ISOMETRIC VIEW
NOTES
1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service.
2. The BIGD shall have a built-in high -flow relief system (overflow bypass).
3. The retrieval system must allow removal of the BIGD without spilling the collected material.
4. Perform maintenance in accordance with Standard Specification 8-01.3(15).
��Y STD. PLAN - 216.30
PUBLIC WORKS CATCH BASIN FILTER
'' DEPARTMENT
N2 MARCH 2O08
3
m SILT FENCE
3 TOP OF FABRIC
` BELT '
TOP 8"
FLOW 1
100% COMPACTION
EACH SIDE DIAGONAL ATTACHMENT
DOUBLES STRENGTH
NOTES:
1. POST SPACING: T MAX. ON OPEN
RUNS 4' MAX. ON POOLING AREAS.
2. POST DEPTH: AS MUCH BELOW
GROUND AS FABRIC ABOVE GROUND.
3. PONDING HEIGHT MAX. 24" ATTACH
FABRIC TO UPSTREAM SIDE OF POST.
4. DRIVE OVER EACH SIDE OF SILT
FENCE 2 TO 4 TIMES WITH DEVICE
EXERTING 60 P.S.I. OR GREATER.
5. NO MORE THAN 24" OF A 36" FABRIC
S ALLOWED ABOVE GROUND.
6. VIBRATORY PLOW IS NOT ACCEPTABLE
BECAUSE OF HORIZONTAL COMPACTION.
Z3OPERATION
HORIZONTAL CHISEL POINT
(76mm WIDTH)
ATTACHMENT DETAILS:
1. GATHER FABRIC AT POSTS, IF NEEDED.
2. UTILIZE THREE TIES PER POST, ALL WITHIN
TOP 8" OF FABRIC.
3. POSITION EACH TIE DIAGONALLY, PUNCTURING
HOLES VERTICALLY A MINIMUM OF V APART.
4. HANG EACH TIE ON A POST NIPPLE AND
TIGHTEN SECURELY. USE CABLE TIES
(50 LBS) OF SOFT WIRE.
ROLL OF SILT FENCE
200-300mm
STD. PLAN - 214.10
PUBLIC WORKS SILT FENCE INSTALLATION
DEPARTMENT BY SLICING MARCH 2O08
SURVEYED:
LN
DESIGNED:
BPF, SP
DRAWN:
SP CHECKED:
BPF, KJG
BY DATE APPR APPROVED:
KJ G
SCALE:
NTS
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
SPECIAL NOTE:
IN THE EVENT TRANSVERSE PATCHES EXIST
WITHIN THE AFFECTED STREET, THE LENGTH
OF THE PATCH SHALL BE EXTENDED TO
INCLUDE ANY EXISTING PATCH WITHIN 10
FEET OF THE EDGE OF THE PATCH REQUIRED
FOR THE NEW CROSSING AND ANY
SUBSEQUENT PATCH EDGE WITHIN 10 FEET
OF THE EDGE OF THE SECOND PATCH AND
SO ON UP TO A TOTAL OF 300 FEET.
APPROVED FOR CONSTRUCTION
BY: DATE: -
CITY OF NEWCASTLE
THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12
MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT
TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD
CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY
APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO
THEIR ACCURACY OR OMISSIONS.
1' 1' VARIES 1' 1'
MIN I MIN MIN I MIN
T_V ,.
�v .•.I:_ .��:: L r� I
i .Ii �•,
TRAFFIC FLOW •t , I'
i I
2" HMA I #•.'.
2" TO 8" HMA I. 4 I
6.5' MIN.
2" DEPTH OF
PLANING OR SAWCUT AND REMOVE
VARIES: 6.5' MIN.
MIN j MIN VARIES MIN I MIN
FACE OF GUTTER OR
EDGE OF PAVEMENT
CENTER LINE OR
LANE LINE
DEPTH OF EXISTING PAVEMENT
!
2" SAWCUT AND REMOVE
OR PLANE, SEAL WITH
2" - 6" MIN. HMA (SEE NOTE 2)
AR-4000W
I .
(EACH SIDE)
6" CRUSHED SURFACING TOP COURSE (CSTC)
2" HMA
PER WSDOT STANDARD
SPE� FICATIONS, COMPACTED TO 95X MODIFIED
PROCTOR,
SAWCUT AFTER BACKFILL
\-CSTC,
(EACH SIDE)
BANK RUN GRAVEL FOR TRENCH BACKFILL
(9-03.19). GRAVEL BORROW (9-03.14(1)) PER
WSDOT STANDARD SPECIFICATIONS OR NATIVE
MATERIAL IF APPROVED IN WRITING BY ENGINEER
BASED ON GEOTECH REPORT, COMPACTED TO 95%
MODIFIED PROCTOR.
WIDTH OF TRENCH AS REQUIRED BY SIZE OF PROPOSED
IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4)
PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF
NEEDED, SHALL MEET THE REQUIREMENTS OF WSDOT
PIPE ZONE BEDDING. MATERIAL- SEE STANDARD
STANDARD SPECIFICATION 7-08.3(1)B
PLAN 110.1.
TRENCH WIDTH
FOR NOTES, SEE STANDARD PLAN 110.1
TYPICAL TRANSVERSE PATCH FOR STD" PLAN - 110
is PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID PPFz ED
DEPARTMENT PAVEMENT WITH OVERLAY 77 �8u -ram
AN
Know what's below.
Call before you dig.
AwtbL
CITY OF
RENTON
Planning/Building/Public Works Dept.
1
u�
�a
z
0
W
Z
Z
O
V
Z
R-396606co
°
IN COMPLIANCE WITH CITY OF RENTON STANDARDS W
0
DEVELOPMENT ENGINEERING SURFACE WATER UTILITY
Justin Johnson 02/11 /2019 rstraka 02/11 /2019 Z
O
0
DATE: W
RHODODENDRON RIDGE 11/1/18 0
PAGE: � 7 / /
ERP PLAN SET OOK 1777 O
PAGE: Q
DRAWING NO: O
STORM DRAINAGE DETAILS D-8 _
SHEET: OF: