HomeMy WebLinkAboutzR-3966SetVAULT ACCESS U SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. APPROVED FOR CONSTRUCTION (jo 1. ACCESS RISERS ARE 48" DIAM. M.H. w/ ECCENTRIC CONE TOP W O / / / / / / / / CITY OF NEWCASTLE KING COUNTY WASHINGTON SECTIONS AS NECESSARY (2'EC = 2' HIGH SECTION; TEC = 3' HIGH I w // // // // // BY: DATE: M SECTION) OVER MIN. 2' DIAM. HOLE IN VAULT PANELS OR GRADE z ; / / / / / / / - _. • • • • • • • :: • • • • • • • :: • • • • • • • • • • • • • • • • • . CITY OF NEWCASTLE RINGS (GR). PROVIDE LADDER OR STEPS TO BOTTOM OF VAULT PER / J.-. . DETAIL SHT. SD-2. O / / / I / / / / / / / 1 . . . . . . . . . . . . . . . PROPOSED THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 2. PROVIDE ROUND LOCKING MANHOLE COVERS FOR ALL ACCESS RISERS. , Q / / / _ / VAULT ACCESS,.TYP. EXISTIIUG MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT _ GRADE, YP. / - - 7. - _ - - - - - - - = s 240 SEE NOTE GROUND, TYP. 240 TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD 1 3. 5'x10' REMOVABLE LOCKING PANEL SHALL MEET THE 2009 KCSWDM / = - I I i I / 7 / - FENCE AT TOP OF CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY Q REQUIREMENTS. / I I I / I. . . . . . . . . . . . . . . .SLOP TYP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO w / / r i N I . . . . . . . . . . . . . . . . . . '. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THEIR ACCURACY OR OMISSIONS. VAULT VENTILATION '�^� N I I a 1 F boo :::: . ... /'I �, ..... NOTES: PR POSE:D:3Fi:Jy RN . 1 . V-1" DIAM. VENT OPENINGS ARE DETAILED ON THE STRUCTURAL I / °° ,•.,,/ � I I I I i 235 SL PE, TYP. @ 235 N A X PLANS. I `� / I I I I 2' MIN. 1 . WORK SHOWN ON THIS PLAN IS LOCATED IN THE CITY OF M 21'.. o / ......... / /: :. Q 2. VENTS IN PARK/LANDSCAPE AREAS SHALL BE 1 2" DIAM. IPS SCH 40 I I /. I / / I\, N . . . . . . . ..COVE.R.: �2 ...... / / / a TOP OF VAULT F NEWCASTLE. IT IS PART OF NEWCASTLE PERMIT ERP1 7-009. PVC PIPE (OR EQUAL) WITH LIGHT DUTY DROP -IN GRATES. . . . . / I / I , 2 / / I N I �' 0/ I O Z I I I N 1 ELEV. 232.Z • a i i• . . . . . . . . . . THIS PLAN IS INCLUDED FOR REFERENCE ONLY. PLANS 3. VENTS IN PAVED AREAS SUBJECT TO VEHICULAR TRAFFIC SHALL BE 12" I `b I I d �' \ SO @ / APPROVED BY THE CITY OF NEWCASTLE SHOULD BE USED FOR 1 DIAM. CLASS 50 DUCTILE IRON PIPE w/ 1 2" DIAM. CAST IRON RING _ _ / I\ /./ ...... I I I \ � 230 100 Y.. . . 230 IMPROVEMENTS IN THE CITY OF NEWCASTLE. AND COVER (OLYMPIC FOUNDRY, INC. PART NO. MHS, OR EQUAL) w/ I �o I VA1LTy4CC�ESS I / /� U 00 2 SQUARE x 1 DEPTH CONC. CL. 5(S) COLLAR. I v I (� %....... f_ COVER / / N LE = 2. ALL STORM DRAIN PIPES MARKED AS "SD" ARE TO BE BUILT .. I -� / FG 235.0 I \ \ I . . . . . . . . . . . . . / SD #4 . . . . . . LU .::`.; :::::: `- USING ALLOWABLE MATERIALS AS OUTLINED IN WSDOT/APWA VAULT CAPACITY: I\ \ ::: T.. PROPOSED OCK & 230.95 . . . / TYPE I-5 MH `�', \ \ N ..I.. STANDARD SPECIFICATIONS 7-02, 7-03 AND 7-04. ALLOWABLE TV 232.8 \ \ \ \ \ N....1 LOAD ALL, 4 / RIM =.23 ..8.3. MATERIAL TO BE DETERMINED AT THE TIME OF CONSTRUCTION Z I I W/ EC \ \ \ \ . .MAX. . . . . TYP. . . . . . / . . I.E. 1 2" OUT (W) = 232.40 UNLESS SPECIFIED OTHERWISE. 0 1. THE REQUIRED VAULT CAPACITY FOR THE 100 YR. EVENT IS 42,718 I I I 225 I.E. 12" I (E) = 232.40 225 CU.FT (0.981 AC.FT.). THE DESIGN VAULT CAPACITY AT THE 100 YR. N I I D . / I I VAULT ACC��S \ \ a o.. 1 5.20' CONDITIONS: 1 PROPOSED.8".SS W.S. ELEVATION 43,354 CU.FT. (0.995 ACRE -FT). 00 '' I COVER \ TYPE 11-54 H \ \ /// . DEPTH: / 1. PRIOR TO INSTALLATION OF THE PIPE THE ^� I I v I o \ w/ SPILL CONTROL & \ CONTRACTOR SHALL FLAG LOCATION OF CLEARING ::.. ? N I I I . I I I I FG 235.6 SOLID LOCKING LID I . . . . . . . . . . . . . . . . . . . . . . . . lc�/1 3" DIA. VENT OPENINGS, I :::::::::::{::: LIMIT OF / LIMIT OF LIMITS FOR THE PIPE. THE CITY OF RENTON STAFF WILL / / / / i I I \ TV 232.8 \ STA. 0+30.00, 0.20 L 1 \ 21.00' 00 TYP. I I I : I I w/ EC \RIM = 256.32 - }::::::: 220 EXCAVATION / EXCAVATION 220 WALK THE AREA WITH THE CONTRACTOR TO DETERMINE � I.�. 1 2" SD IN (NE) - 249.00� ""' . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . THE EXACT LOCATION OF THE PIPE THAT WILL MINIMIZE 2 TOTAL ::::.:::.::: LL I N I I.E\12" SD OUT (W) = 249.00� " :\ :/: : : THE IMPACT TO THE HILLSIDE. M 13 \ 29 LF 12" 1 1 N 1 1 . . . . . . . . . . . . . . . . . . . . . . . . \ O 5 x10 REMOVABLE x L4 ....1..... I o 21 L 1 2°" SD SD #5, 8)0 1 PEAK \ SD @ 2.44% \ / LOCKING PANEL 1 I L . I I @ 10.00/ DIVERSION STORMFILTER \ \ . . . . . . . . . . . . . � / 2. SLOPES SHALL BE STABILIZED WITH HOG FUEL, A BO OFSTORAG Q I I 1 STA. 0+77.00, 0. 4' RT \ I 215 ELE ..= 21 5.75 . / MINIMUM OF 6 INCHES DEEP BY 6 FEET WIDE AS I FG III I.....I l \ a... 215 TV = 232.8 x II I I ..:. _:. I .:.:_:_: I \\ �I TRACT D RIM = 250 00 . . . . . . . . . . . . . . . . . . . . . . . . . . - DESCRIBED IN SECTION D.2. 1.4.2 IN THE CITY OF � / B T OF VAULT I I.E. 1 2" IN (E) = 247.80 45 LF 1 2' ° ° ° - J. E EV. - 214:00 RENTON SURFACE WATER DESIGN MANUAL. r- 1 FG 235.1 I I I \ \ (ACCESS) I.E. 1 2" OUT (W) = 244.75 s\D @ 6.66° - - - - or_, I\ \.__ TV 226.5 \ 6" RAVEL BED . " AVG. SEDIMENT CY) .... ...I..._._ 3. PIPE SHALL BE KEYED IN BY A MINIMUM OF 1 FOOT SO \ I I �.......... �o ) STORAGE DEPTH \ I THAT THE PIPE IS NOT VISIBLE FROM THE SURFACE. x v.. :..... 210 ......... ......... ......... ........("TOTAL::: ........ ......... ......... 210 i......1...... \ /STORAGE DEPTH) I 1 \ / I \ .....\... 15 /° P.M. X SLO .... i . j....:.... �.......... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I \ \ I �.....\ . LF 2 14.1$f.. l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . \ _ ......... ......... ....... ..... ......... ......... \ _ V ULT SE TION A A I x ..... ..................... O \ \ \ I \...... ........... 16�/ .-.`.'.. /.. SCALE: 1' =10' HOR: ............ 1 \\ VAULT ACCESS i I II I l..... I... / ............ 205 ........ ......... .........'-........ 205 Q \ \ C_0VER I I \ .......\...... \ / n D ...:: , .ER ..... ......... ......... FG 235,1I ,.,.1 z z ACCESS PAVEMENT SECTION CONSISTS W TV 232.8\ `2 I \ I I I z m / a OF 2" HMA C 'OVER 4" H A CL %4" ON z ui $D #4, TYPE I-54 MH z q . . . . . . . . . . . . . . . . . . . . . II . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..6".COMP CT.ED.S.UBGRA E (9.5%.MAX.. j Q w/ EC \ I o I PTA. 1 +57.99, 3.35 L O VA LT ACCESS, P. DRY DENSI Y) PER CITY Q NEWCASTLE a O10 40 \ I a� 1' III I � IM - 237.83 I"I"I // 240 . . . . . . . . . . . . . . . . LU . . . . . . SEE NOTE: : : : : : PUBLIC WORKS STANDARDS.LLII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 Q I I I E. 1 2" SD IN (E) = 232.40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SECTION 4.3 - 4:37, TYP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I � o W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Q 0 20 60 I \ 34... I I I.E. 6" RD IN (N) = 232.90 \ . . . . `!1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . \ I o II I.E. 1 2" PVC OUT (W) = 232.4q \ FENCE AT TOP OF : : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCALE: 1 " = 20' \ \ x I. ....... LOPE; TYP... .... ...... ......... ......... ......... ......... ....... ....... ......... ......... ......... ......... ......... ......... ......... \ \ I i12" SD VAULT INLET 1 \1 4 ALL RETAINED TREES MUST / SCALE: 1 "=10' HOR. 51 LF 1 2" PVC @ 6.82% \ HAVE TREE PROTECTION PER / 1 "=5' VER. \ \ \ \ \ \\ \\ CITY OF NEWCASTLE PUBLIC ` WORKS STANDARDS GOLDSMITH LAND DEVELOPMENT SERVICES 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 T 425 462 1080 F 425 462 7719 www.goldsmi hengineering.com JOB NO. 14134 1 iCAP RHODY RIDGE, LLC 11/1/18 S . G of o IIV VVIIIU L/A/rVL III I I I V■ ■ ■ VI I\L/r ■ WEV V I /9/rLJP7■\LJV (I� 0 DEVELOPMENT ENGINEERING SURFACE WATER UTILITY Ar,�i Justin Johnson 02/11/2019 rstraka 02/11/2019 Z O ,c, of WAS . ti j �' h� � o '� 60 z 24597 ,� o,� sICISTE�'� ANAL F' Uj Q Q O Z SURVEYED LN SCALE: L 1" - 20' VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY O F ' RENTON • Planning/Building/Public Works Dept. RHODODENDRON RIDGE ERP PLAN SET DETENTION VAULT PLAN & SECTION DATE: 11 DESIGNED: BPF, SP FIELDBOOK: 977 PAGE: 27 DRAWN: SIDIft ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DRAWING NO: SD-1 cHECKED:BPF, KJG NO. REVISION BY DATE APPR APPROVED: KJG SHEET: 1 OF: 6 VAULT ACCESS Q0 1 . ACCESS RISERS ARE 48" DIAM. M.H. w/ ECCENTRIC CONE TOP SECTIONS ai AS NECESSARY (2'EC = 2' HIGH SECTION; TEC = 3' HIGH SECTION) OVER M MIN. 2' DIAM. HOLE IN VAULT PANELS OR GRADE RINGS (GR). PROVIDE LADDER OR STEPS TO BOTTOM OF VAULT PER DETAIL SHT. SD-2. O 2. PROVIDE ROUND LOCKING MANHOLE COVERS FOR ALL ACCESS RISERS. I LU O t� V Uj z ♦O V z OL 1t'�^ ♦W V O ct O W O O O TOP OF VAULT ELEV = 232.79 INSIDE TOP OF VAULT ELEV = 231.75 100 YR. W.S. ELEV = 230.95 ROUND SOLID COVER WITH LOCKING BOLTS ZVAULT ACCESS SEE NOTE NOTCH 1 "WIDE BTM ELEV = 230.25 ORIFICE ELBOW PER C.O.N. DETAIL SW-18 PIPE SUPPORTS PER C.O.N. DETAIL SW-1 8 CLEANOUT GATE: SHEAR GATE WITH CONTROL ROD, PER C.O.N. DETAIL SW-1 8 FLOOR GRATE WITH 2'X2' ACCESS DOOR 0 "xl /4" GALVANIZED METAL BARS) SEDIMENT STORAGE ELEV. = 215.7 n INSIDE BOT OF VAULT F,< ELEV. = 215.00 a. BOT OF VAULT ELEV. SEE STRUCTURAL PLANS ° 5.5' N 1' SECTION OF 1 8" PIPE ATTACHED BY 0 GASKETED BAND TO ALLOW REMOVAL. PER C.O.N. DETAIL SW-1 8 ° 4 5.5' DEPTH - TYPE II 48" CB SUMP ELEV. = 210.25 a ►"I GOLDSMITH LAND DEVELOPMENT SERVICES w 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 a T 425 462 1080 F 425 462 7719 www.goldsmi hengineering.com JOB NO. 14134 iCAP RHODY RIDGE, LLC ° 4 2' COVER MINIMUM FI _•j a 4 4 a nAE FAI 2.0' =m 4 ° 2.0' a ° a 1 8" RISER ELEV. = 230.75 VAULT WALL DESIGN BY OTHERS ORIFICE NO. 2, ELEV. = 226.45 ORIFICE DIA. = 1 .1 5" ORIFICE NOR FO. �ICE DIA. � 1?205 KNOCKOUT DIA.= WALL THICKNESS + PIPE O.D. 12" OUTLET SEE SHT. SD-3 FOR I.E. = 214.25 OUTFALL PROFILE ORIFICE NO. 1, ELEV. = 212.25 ORIFICE DIA. = 1 .1 8" SEE STRUCTURAL PLANS FOR SUMP AND FOOTING DESIGN NOTE: SEE FLOW RESTRICTOR DETAIL SW-1 8 FOR ADDITIONAL REQUIREMENTS. STORM DETENTION VAULT CONTROL STRUCTURE SCALE: 1 if= 2' 11/1/18 S • G OLd of WAS w j xw,7 z x 24597 BOA �GISTF"V- SSIONAL NO. SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. CITY OF NEWCASTLE, KING COUNTY, WASHINGTON INLET BAY o ALTERNATE o� PIPE LOCATION OUTLET BAY 3'-3" 0 O TRANSFER HOLE AND COVER LL I I I I -- L-1-r-=\----_------------ -1 L___�_LL_LJ 1_L _\L_ \1 _ \L_ I r I - Ij --0 I 1 I 1 \ - %t\ i it I I I r�---� -�-�+- -� II 1 1 F-i---�- -/ -- / L I I I I I LJF- -ice- -tJ`-- \L- \ I O j I I LL -- r-J-L - ----------- -� I STORMFILTER I I I CARTRIDGE FILTRATION BAY PLAN FRAME AND COVER (TYP OF 2) SEPARATION WALL] GRADE RINGS/RISERS (TYP OF 2) �iX INLET PIPE --------- �� ----------- ---- ---- I STEPS WEIR WALL I I I I I Io 14/ ICJ I II II II r I I II II II 3 � I I I II II II I ci� I I II II II I - -- - - �1 ---- - -�� - IL - 1 r--- --_- _- _ OUTLET PIPE STORMFILTER FLOW KIT CARTRIDGE ELEVATION Tl,e SNrn,waer Marwgeme�M StormFilter' SOLID CMER MARI® 'DRAIN' f WITH BOLT LOCKING RING AND COVER. - ATTACCII SC" TO CROSS wW 8 1' SEE NOTE 11. MET METH. SCREWS-2 PER . ._. F.FRAME • UDDER OR m'PIIPPE CCLjAMPNNlES3 OVERFLOW ELEV. PER PLANBJ"ws. SEE NOTE 10 AND 12. PIPE BIRPORIS ((ALU MM2UUWN./ �Y - 51ir AINIESSNBOLTS I g1NET PIPE INVERT ELEVAUM PER PLAN j 4. REST a" ORIFICE AS SPECIFIED PLATE BOLTED TO FLANGE OR DRILLED GAP. 4 1 54' MN. I CATCH BASIN TYPE 2 NOTES: DIAM. AS REQUIRED 1. PIPE SIZES, INVERT ELEVATIONS, ORIFICE SIZES, OVERFLOW ELEVATIONS AND SLOPES; PER PLANS. 2. OUT.Er CAPACITY: NOT LESS THAN COMBINED INLETS. 3. EXCEPT AS SHOWN OR NOTED, UNITS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS FOR CATCH BASIN TYPE 2, 54' MIN. DIAM. 4. PIPE SUPPORTS AND RESTRICTOR SHALL BE OF SAME MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY 5/8' DIAM. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2' IN WALL. S. THE RESTRICTOR SHALL BE FABRICTED FROM .061 ALUMINUM, PVC, CPE, OR HDPE PIPE PER THESE ENGINEERING STANDARDS. 6. OUTLET SWILL BE CONNECTED TO CULVERT OR SEWER PIPE WITH SUITABLE C CONCRETE PIPE. OUPLER OR GROUTED INTO THE BELL OF 7. THE VERTICAL RISER STEM OF THE RESTICTOR SHALL BE THE SAME DIAM. AS THE HORIZONTAL OUTLET PIPE, WITH AN W MIN. DIAM. 8. FRAME AND LADDER OR STEPS OFFSET SO THAT: A. SHEAR GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS CLEAR OF RISER AND SHEAR GATE C. FRAME IS CLEAR OF CURB. 9. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4'. 10. MULTI -ORIFICE ELBOWS MAY BE LOCATED AS SHOWN OR ALL ON ONE SIDE OF RISER TO ASSURE LADDER CLEARANCE 11. SHEAR GATE HANDLE SHALL BE ATTACHED TO LADDER/ STEP LOCATED WITHIN 24" ACCESS SECTION. 12. IF NOTCHED WIER IS USED IN LIEU OF ELBOW, BAFFLE SHALL NOT OBSTRUCT ACCESS TO THE STRUCTURE SURVEYED: LN DESIGNED: BPF, SP DRAWN: SP CHECKED: BPF, KJG REVISION BY DATE APPR APPROVED: KJ G STEPS OFFSET. BEE NOTE 8. 4 - 9wx1*x126 GA 12' GALV. STRIPS TACK WELD TO WIRE MESH. SHEAR LATE L GALVI 8ME� SOLID 12 GL CALV.J/ TACK WELD WIRE MESH BOTTOM PLATE To BoT1011 PLATE 36' MIN. DIA. rwE FLOW CONTROL SCREEN INVERT ELEV. PER PIA! Ta COu� - ,zI PLATE WITH ORIFICE AS SPECIFIED, BOLTED 70 FLANGE OR DRILLED CAP ELBOW DETAIL CITY OF NEWCASTLE FLOW RESTRICTOR TEE TYPE APPROVED: DWG. NO. ROGER KUYKENDALL, P.E. 8/1/2000 SW-18 BY CITY DATE NOTE: APPROVED FOR CONSTRUCTION 1) WORK SHOWN ON THIS PLAN IS LOCATED BY: DATE: IN THE CITY OF NEWCASTLE. IT IS PART OF CITY OF NEWCASTLE NEWCASTLE PERMIT ERP1 7-009. THIS PLAN IS INCLUDED FOR REFERENCE ONLY. PLANS THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT APPROVED BY THE CITY OF NEWCASTLE TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD SHOULD BE USED FOR IMPROVEMENTS IN CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO THE CITY OF NEWCASTLE. THEIR ACCURACY OR OMISSIONS. STORMFILTER DESIGN NOTES • THE 8' x 1 V PEAK DIVERSION STORMFILTER TREATMENT CAPACITY VARIES BY CARTRIDGE COUNT AND LOCALLY APPROVED SURFACE AREA SPECIFIC FLOW RATE. PEAK CONVEYANCE CAPACITY TO BE DETERMINED BY ENGINEER OF RECORD. • THE PEAK DIVERSION STORMFILTER IS AVAILABLE IN A LEFT INLET (AS SHOWN) OR RIGHT INLET CONFIGURATION. • ALL PARTS AND INTERNAL ASSEMBLY PROVIDED BY CONTECH UNLESS OTHERWISE NOTED. CARTRIDGE SELECTION CARTRIDGE HEIGHT 27" 18" LOW DROP RECOMMENDED HYDRAULIC DROP (H) 3.05' 2.3' 1.8' HEIGHT OF WEIR (W) 3.00' 2.25' 1.75' SPECIFIC FLOW RATE (gpm/sf) 2 gpm/sf 1.67* gpm/sf 1 gpm/sf 2 gpm/sf 1.67* gpm/sf 1 gpm/sf 2 gpm/sf 1.67*gpm/sf 1 gpm/sf CARTRIDGE FLOW RATE (gpm) 22.5 1 18.79 1 11.25 15 1 12.53 1 7.5 10 8.35 5 1.67 gpm/sf SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORB ° (PSORB) MEDIA ONLY FRAME AND COVER (DIAMETER VARIES) N.T.S. SITE SPECIFIC DATA REQUIREMENTS STRUCTUREID SD#5 WATER QUALITY FLOW RATE (cfs) 0.41 PEAK FLOW RATE (cfs) 3.07 RETURN PERIOD OF PEAK FLOW (yrs) 100 CARTRIDGE HEIGHT (27", 18", LOW DROP(LD)) 27" NUMBER OF CARTRIDGES REQUIRED 17 CARTRIDGE FLOW RATE 111.3 GPM MEDIA TYPE (PERLITE, ZPG, PSORB) ZPG PIPE DATA: I.E. MATERIAL DIAMETER INLET PIPE 246.50 12" OUTLET PIPE 243.45 12" UPSTREAM RIM ELEVATION 250.00 DOWNSTREAM RIM ELEVATION 250.00 ANTI -FLOTATION BALLAST I WIDTH F HEIGHT NOTES/SPECIAL REQUIREMENTS: PER ENGINEER OF RECORD PERFORMANCE SPECIFICATION FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. SPECIFIC FLOW RATE SHALL BE 2 GPM/SF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPM/CF OF MEDIA (MAXIMUM). GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY. 3. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH REPRESENTATIVE. www.contechES.com 4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. 5. STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0' - SAND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. INSTALLATION NOTES A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE (LIFTING CLUTCHES PROVIDED). C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT PIPES. MATCH OUTLET PIPE INVERT WITH OUTLET BAY FLOOR. E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. F. CONTRACTOR TO REMOVE THE TRANSFER HOLE COVER WHEN THE SYSTEM IS BROUGHT ONLINE. C►NTECH• THE STORMWATER MANAGEMENT STORMFILTER ENGINEERED SOLUTIONS LLC $' x 1 V PEAK DIVERSION STORMFILTER www.contechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 STANDARD DETAIL 800-338-1122 513-645-7000 513-645-7993 FAX AN Know what's below. Call before you dig. SCALE: VERTICAL: NAVD 1988 VARIES HORIZONTAL: NAD 1983/1991 CITY OF %R RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept IF NOT ONE INCH SCALE ACCORDINGLY �a z O r� V W CO`] V O R-396602 W IN COMPLIANCE WITH CITY OF RENTON STANDARDS W DEVELOPMENT ENGINEERING Justin Johnson 02/11/2019 O 0 DATE: RHODODENDRON RIDGE W ERP PLAN SET FIELDBOOK: 1977 O PAGE: 27 / / Q DRAWING NO: O DETENTION VAULT CONTROL STRUCTURE DETAIL SD-2 = SHEET: OF: 2 6 01 7 0 = 0- Of w T E 0 12 w M H Q 0 v : 7 Z (.0 I\ C, I I I I ► \ \\ I / ICI, � I I I I I // � \ V, \ - \\\\- \\\ SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. 1 \ I II / / l \ �� � CITY OF NEWCASTLE, KING COUNTY, WASHINGTON / �, I \ 1 / 1 1 II II \ � III\ •, -, �i I I III I I \ I I \1\ 1 I I (( I I I I 1 \ 1W\\ � \ \ \ FLOW CONTROL STRUCTURE M ✓ � I I I I � !) I I � 1 \ � \ \ I.E. 12" OUT = 214.25 n I I I I I I I I I I I III \ J/ IIII I I I I� \ \ SEE SHT. SD-2 FOR DETAIL. \ O I I I III / I �I 1\\ I /�// l 11 // I I/ l I 1\ �� x Nt I 1 /// ) II IIII II l �/III /I \ \ \\ �� ., I I ) I I// / I I I I I I I I I 1 !' / I I I I 1/ I I\ \ \\� I \ 1 i\�LF 12" PVC PIPE o I IW �// ICI �I III f (O1(II �oI (OII I� o� 1 \o \ o\�\o \ w O I xI � � I l / I I I `- I \ � \\ 1 I \ \ � � \ \SD 3 T�'PE II 8 �B \ I -- \ - - _- - - = APPROVED FOR CONSTRUCTION _ _ _ \ � I I Lr / / / BY: DATE: I� b I I / / � ( � CITY OF NEWCASTLE I / I I / I/ I I I 44� \\\� THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 I II I 1 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT p ` TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD \ - -\ -� - CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY �-_ I - _ _ APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO -\ \ \ THEIR ACCURACY OR OMISSIONS. CB I `f y I D IS D #11',li(��� I CB / / / /INSTALL HIGH VISIBILITY \\ j \\IIIII11\\I ` \ \\ 1 I I \ w/ SOLI@LOC ING LI I 1IRIM_55.21 = IS A.�O 00. 0�//RIBBON ALONG EXISTING \\570 LF 12" I I I E SDR-1 1 PIPE \ I \ I I 1A. 6 88.03, 0.00' \ 1 \ I \ IE 8 (SE) CMP=51.31 � Cr F CILI7I lD�' 1 4135 / I( \ \ I �OR ST . �AN 201.00 \ I �\ \ DMH . Irn C I I SS MH/SD PIPE I 1 l ( CLEARING LIMITS, TYP. I I I ON SURFACE. PIPE INSTALLED \ \ \ \ \\ \ \ \ \ �7\ RIM=55.88 m I I \ \ \ I I I BETWEEN CLEARING LIMITS TO \\ � \ l \\ \ \, \ \ ) 51 LF 12" PVC PIPES I1 I I �( ) I I I HO- EP. I11 I I 1 \ \ \\ \\ \ \ 1I / 1 I I 1 AVOID TREES. \ \ _ \ \ EXISTING 8 1 ` \ DAYLIGHT PIPE \ 2 4 'PROPOSED 8" I I I Z IE 18 SE CMP=52.68 C 00 I \ l �SD-- 2, TYPE II-48 CB I ✓ / \ \ \STEEP SL6PE, \ \ I \ SANITARY SEWER 1 \ TO SURFACE \ \ ) A SANITARY SEWER I I 0 IE 12"(N) CMP=51.38 I nl I � -w/ SOLID LOCKING LID \ \ �\ \ I \ \\ TYP\\\ \ � \\ \ 1 L � - \ \ @ STA. 6+1 1 .49 \ / �� . - _ _ I J' , 0 IE 8 (NW) CMP=51.38 I^ STA. 0+49.45, 0.00' � C I \ \ \ � �/ \ \ �/ I`Y",I , \� \\\ \ -, IE - 202.5+ � r �Ic Pi °1 1 I INSTALL INLET PROTECTION ON 0 e rrz - mD RI I Yl COR .PLAN 201.00 I \\ \ \\ �-o al 01 �I\ \\ \ \ \ �� \ �- ' \� l / ( I \ \ � AI \ 1, I �i EXISTING CATCH BASINS WITHIN °"' 0 \ �/ \ \ \ \\ \¢I I J / I 1 + I I o�/ \ \ I I No 03 \ \�� . \ \ CITY OF'NEWCA TLE .- \ �,/ I \ I o ow \ ) K LV 200' OF PROJECT PER COR STD. F I I Z PLAN 216.20 OR 216.30 (TYP. ► l \ 50 LF 18" HDPE �'? \\ \ \ \ \ I II x k CIT F T N 10- A � - _�d - \ I Z EXIST. 12l'' SD PaNEo�ocnnorq W I I I $DR� 11 PIPE � , \\ \ \ 1 \� \ \ / \ \ \� �� I \ / \ \ \ OCB I W/ SOLID LID I - - - - 8'- WA (RECOR " S 3 S \ S S � L I �� - NRIM=57.94 d S% 0 � - �\ �_ \ \\c \\ V IE 18"(N W - \ \=--- / \ k I� fi T_ \ \ Sd\- , CMP=54, 84 _ g I I+ \ \ \ \ \ \ I I I ( WPRgV D 3� \ \ \ �� \ ���\� Q IE 12 (S) So \ \ \ I I� ►p Id „ a \ 1 � ��� \� \\�' CMP=54.84 I I p SLIDE 7.5' LENGTH OF 12 HDPE SDR-1 1 PIPE > ) R 1� IN RENTO \ \2�\� SS/SD CROSSING / o \ `INTO 10' LENGTH OF 1 8" HDPE SDR-1 1 PIPE 1 / I 1 INSTALL SILT FENCE WHERE SS/S CR �NL_ ALL RETAINE[_T S3��\� N: 1 96721 .83 ` I \ z I I I I \ (I I 1 I I I - UNDERGROUND STOR \ N: 67 6. 0 \ HAVE TREE PROT CT[QI*PER�- @ STA. 0+98 IE = 68.2- c I I TYP. ti E: 1304420.22 + -� � \ I EXISTING SANITAR SEWER -CITY OF NEWCA TLE PU C� N� \ \ I END PIPE ON SURFACE'ANb BURY A I I I \ I l \ I I I � \ \'\ \\ PIPE ANCHORS 10 O.C. INSTALLATION TAKES_ \ \ 15�1 3 5 37.53- TOP 8" SS = 50.64 1v ` UNDERGROUND @STA. 0+83, IE = 66.1 ± 1 1 \ VERTICAL SPACING PER n ct BOT. 1 8" SD = 54.92' \ � � 1 I II I I I I \ PLACE PER COR STD. PLAN \\ ) n :� T P S = 203.62 WORKS STAjVDA DS. \ 1 O VERT. SEP = 4.28' 1 SILT FENCE (TYP.) \ \ \ \ \ \ \ 1 I \Ej(ISTING �DGEIOF CLEARING, TYP \ \ l l l ,COR STD. 221 .20. 214.00 OR 214.10 (TYP.)\ 1 / � o � . 1 SD = 205 � \ \\ \ 34 LF 12" D.I. PIPE x I 1 5 LF 12 PVC` PIPE \ �� \ \ ► \ \ \ \ SEE �S \ 26 LF 12 =R-1 1 PIPE / p „ \ tKl� SF9 \ �2220 80 m �,SD #1, TYPE I CB h o \ \ \ \ \ , \ , I I \ \ 1 I I I I I ` \� \ � \ �\ �\ T�1 PE_ B I „ � � � � \\ w/ SOLID LOCKING LID % . \ \ o \ o \ \ O \ O \ 0 1 I I o I \ '?o\ \ \ o\ \\\ �6\\ \\>_ \ \ \ _ w/ SOLI i I�TNG _ I � - - \ \ W !!Im I STA. 0+34.45, 0.00' �j�\ \ \ \ \ \ \\ \\ \ \ I I \ \ \ \ \\�� O\ �& CHANNELI 6§QT 1 0� �'IN I n \ �17O- -21 Q::- 7 \ 0 40 120 / 1 r0 CONNECT TO EXISTING CITY OF RENTON \ \ I \ \\ I \\\ \ \ \ \ \\\ \ \\ \�\\\ \ \\\ � STA 6+37��14, 00 1 � �� � \ - � � � �\ '-,\ \ SCALE: 1" = 40' Ill j STORM AT EXIST. 12" CULVERT, SEE \ I I 1 I \\\\ \ 1 \ \ X \ \\\� \ \\ �� ���STD P4N�20�. //I I I I ^' \� \4 I IIPROFILE BELOW FOR DETAIL. / / I I II, ► \ \ � ► � I I I \ , \ \\ �\\ �\\ \ \\ - � � ,,\\�\,� \ �� -- _ � , , I / I I \ \ \ - \ . � 1 I , \ I ct ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: DETENTI N VAULT: Z ......... ......... ......... ......... ......... ......... ......... ......... ......... EXISTING GRADE, T O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. ... . . . . ........ ......... ......... ......... 51 LF 12 PVC 6.80%IIII. , .. -. 220 W......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ........ ......... ........ H HDPE 04%IIII.. ...... ......... . ......... ......... ......... ......... ......... ......... ......... ......... ......... ........ ...... . ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... PIPE ANCHORS I0:0.:C. ... O ......... ......... ......... ......... ......... ......... ......... ......... ......... VERTICAL SPACINGPERCOR j:: ...... ....... ......... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ..... IIII STD. PLAN 221.20 TYP: ...... ......... . ....... ......... ...:13�4LF12`......... Q 200 ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ..... IIII ........ ......... ..... ... � �... . ....... ......... ....PV. % ..... 200 0 ......... ......... ......... ......... ......... ......... ......... ......... ......... : : : �........ �: ct ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... �� ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ....... .. a ......... � �....>.. .... .... I.... ..... ......... ......... ......... ......... ......... ......... 180 ......... ......... .....IIII 195: �: ........ ... ... ......... ......... ......... 180 i ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... .. �'I..... /........ IIII.<.�. .. .J r.-•...Q...m J- ^.� ......... ......... ......... KInTCC - 1 . WORK SHOWN ON THIS PLAN IS LOCATED IN THE CITY OF NEWCASTLE. IT IS PART OF NEWCASTLE PERMIT ERR] 7-009. THIS PLAN IS INCLUDED FOR REFERENCE ONLY. PLANS APPROVED BY THE CITY OF NEWCASTLE SHOULD BE USED FOR IMPROVEMENTS IN THE CITY OF NEWCASTLE. 2. ALL STORM DRAIN PIPES MARKED AS "SD" ARE TO BE BUILT USING ALLOWABLE MATERIALS AS OUTLINED IN WSDOT/APWA STANDARD SPECIFICATIONS 7-02, 7-03 AND 7-04. ALLOWABLE MATERIAL TO BE DETERMINED AT THE TIME OF CONSTRUCTION UNLESS SPECIFIED OTHERWISE. 12„ PROVIDE RUBBER O-RING GASKETS AROUND 36" HDPE d. d 6" HDPE ADAPTER 'I 12" III I I GROUT SHALL BE MASTERFLOW I I I I 928 EXTENDED WORK -TIME I I I I I HDPE PIPE NONSHRINK GROUT OR EQUAL. INSTALL PER MANUFACTURER'S I I I I I RECOMMENDATIONS III I I 1 d d. 2" MIN. 4 EA. # 6 REBAR d a dQ C.R. d as ,�AS SHOWN PROVIDE CONCRETE SUPPORT WALL, FULL DEPTH WITH A NOTE: CONTRACTOR SHALL MINIMUM OF 12" AROUND TOP SUBMIT SHOP DRAWINGS PRIOR AND SIDES TO CONSTRUCTION. HDPE CONNECTION DETAIL N.T.S. (SEE MANUFACTURER ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: ::::::::: 570 LF 1.2" HDPE SDR 1 1 PIPE . ......... ...... . . O°: : ::I: %:�::: �: : m:Z m �: N l7 0 : : o ri . II . . . . . . . . . . . . . . . . . . . . . ......... ......... ......... ......... ......... ......... ......... ....... ONEXISTING GRA E,TYP. .... ..y� ....... ......... .....N.+. v. p II. Y o..^'.�. ..... ......... ......... I�„ ......... ......... ......... ......... ......... ......... ......... ......... .... .. ......... .... , ... \ ......... ......... ... .�. .0 W _ w R 1-2 .1.1i .... ......... ......... NpP 160 160 R.zp Q _j W `' CL_ "Z 17 ......... ......... ......... ......... ......... ......... ......... ......... ......... ........ ....... °la ...... ......... ......... ... d.V). t�.Z. p _.p. � 0 00 _.Z ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ... ...nJ2� .. �/. //........ ......... ......... ... d �L^ +I N.0 Q = N N(V.. Il M 0 O � NfV. II^.�. ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... .. / �. u.fV. ....�.�.U. *cn �_ w.LLi.�uiui 3:nCC- �S'CF ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... /IIII .J.O V)�0.� OC- - LA - ..... ......... ......... 140 .. ..... j1,..... ., �..... ........ ......... ......... .....Q n.W II . ......... .....I... ......... ......... ......... ......... ......... ......... ......... 140 " 0 . . ./j ......... ......... ......... ......... ......... ......... ......... ......... ......... nj'. / �. ......... ......... ......... ......... . . . . I . . . . ......... ......... ......... SLIDE 7.5' LENGTH OF 12" PIPE ......... ......... ......... .......It. ......... .. 1 ......... ......... .... .i. .... ..... ......... ......... ......... ......... ......... ......... ......... ......... ......... INTO 15' LENGTH OF 1 8" PIPE. M ::::::::: ::::::::: :::: : : : . . v o - J . . . . . .o . :o . . o .u° : ::: : : : : : : ... . . . . . . PIPE AN VERTICAL SPACING HORS 10 O:C. PER COR : ...... .. . .. 0 a i ,Z351. �: �.SS ......... Q 120 ... . . . . . . :: . . . . . :: ... . . . . : oo z :o : :,M : 11 : o,=. ::::::::: :: :STD. PtA .. 221:20, TYP• .. :. ..: : : : : . . . ... �S�'... 120 �111 (%) ......ICU. ... d. U I- U.. .,d.. N - .Uj p 0 Lrj v. ......... ......... ......... .. .. 0 o i j. ... ...... ......... ......... .. ......... ..... ........ 4) . pN.N Z.p I- I- > O N . 1. d I- J D.d ,,,.,.. .� N. � . z.p. . . . . . . . . . ......... . . . . . . . . . ......... . . . . . . . . . ......... . . /. _,- ...... ......... ......... ......... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... �U, �.s. � m . u R. W J Z O u O Q �..II. _z: N J.+ 0 N �.-..-. .p . oo rv/ ... . 11 ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... 100 W0..,4.�. L" O' Ln.� _ a O.� H:w Nin r 't .II.Z. Hurl-: p N.a.11 �:� r- -LWLu: ......... ......... .. �!, °a / .. `?.6 i /.... ......... ......... ......... ......... ......... ......... ...... ......... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... 100 � �' ��� Ln � V) OC_ - . O. ^'' N ' d...� . H 'zpi�0 U.i W Vi _ M + 00 !,=. Ln = Il �.N ... - .. ......... . . . . . . . . ......... . . . . . . . . . ......... . . . . . . * �* . . �% ......... ......... ......... ......... .... IIII. ...... ......... ......... ......... ......... ......... ......... ......... ......... ......... O,z . }O Z.W. . 00 Z....Q 2.:� LLLW. ......... ......... ......... ......... ..... .... .. ^'�.�...... `� ...... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... � N. 11 7-.\. Vzu.0.,(noC- _. . ... ... . ....... ......... ......... ......... ......... ......... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... �.�.�. : . :: ..... :.... ...... ...... 50LF SDR-II.PIPE:: 8"- HDPE .� �:� ......... ......... ......... ......... ......... ......... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... 80 4u , i _. .: ......... ......... ......... ....... ......... ......... ......... ......... ......... .....IIII 80 . . . : ... .:. . ...). . . . . .... . . . .. .: . . ..: ..:_... . ...... ,. . to � i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . : ....... ::::: .. ::. ..... :::: ...... ::: ..... . . ......... .....IIII ......... ... ......... ......... ......... ......... ......... ......... ......... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... :::.. :. :::: . .I .... ._.,. . ... SLIDE 7.5' LENGTH . F 1.2.,, :PIPE ::::::::: :::::::: . . . o 2 INTO l 0 . LEN:GTH: 0 18 : PIPE ......... ...IIII.. 60 /.... .IIII _ ...... @ ST . 0+98, IE = 6 :2+ IIII.. ......... ......... 60 ::::.�. - p�. .IIII.. :::::: ::::::::: ::::::::: . � . ...BEGINPIEBE...... ........ ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... .y .. ...ANDBU YPIPEATSUR ACE ....... ......... ......... ......... ......... ......... ......... .. .... ......... ......... ......... ......... ......... ......... ......... ......... ......... BURY PIPE AT END OF -1 SLEEVE PER PLAN. EXISTING GROUND, TYP o� IE 18" IN = 53.04 SD #2 TYPE II-48 CATCH BASIN W/ SOLID LOCKING LID COR STD. PLAN 201.00 J� �O �7 _F ti O AF 36" 24" MIN. r- O rn O I A H H I� Q N-12 OUT O - IE 12" IN = 56.04 V Uj Z O V SLEEVE CONNECTION & SUMP DETAIL Q NTS Q z 2 ......... �,; .... . . STA. O+ 3, IE = 66:1.±. ... ......... ......... ......... S.TORNf D: IN O,UTFA L PROFILE ....... ......... ......... ......... .. I I I I ... I I I I I I I I . I I I I I I I I . ...... 34 L 12 . :::: 1 5 LF 12" : :: . . . . . . . . . . . . . . . . ......... ......... ......... ......... .........S ALE. 1 "= 40? li . . .. ......... R-396603(/, ............................... 40 ::::b.l.:@.11:8%:::::: .PVC @5... ......... ......... ......... ......... ......... ......... ...1„=.20' .. ......... ......... ......... ......... ......... ......... ......... ......... ......... 40 LI ......... ......... ......... ......... ......... ......... ......... ......... ......... IN COMPLIANCE WITH CITY OF RENTON STANDARDS ......... ......... ......... ......... ......... ......... Ifl ^ . . . . . ^ . . . . . . N . . . . . . . . let (" 00 n V1 N • D'1 IIII... n IIII... N N ...... ..... IIII... IIII... IIII... IIII... IIII... IIII... IIII... IIII... IIII... IIII... IIII... IIII... IIII fV Op N N ^ N N ^ fl0 O 1,p C1 M M QO n O V1 00 Ci 00 00 N 0 :fl V l0 . N W tC N n l0 00 l0 M '� 0 , of I of o v v Qd ao � a ci " `4 � o � � ^ v ^+ N "+ �+ � DEVELOPMENT ENGINEERING � n O W NN M O N �1' U1 O 00 00 O O OO NN NN NN . ........u,at n�.......Do� ......o, o....... �.........,�N.......,��....... �u,....... �W....... �oo.......,�ao....... �c,...... o...... SURFACE WATER UTILITY . . . . . . . . . `n. . . . . . . . . 1. . . . . . . . . t. . . . . . . . . . . . . . . . . . a. . . . . . . . . On . . . . . . . � . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NN . . . . . . . NN . . . . . . . NN . . . . . . . NN . . . . . . NN NN ......... ......... ......... ......... ......... ......... ......... ........I ......... ........ ..... ..... ..... ..... .. Justin ........0 00......0 40......0 80..1.420 1460 2 00 2 40 2 80 3 20 3 60 4 00 4 40 4 80 5 20 5 60 6 00 6 40 6 80 7 20 7 60 8 00 Jus 'n Johnson 02/11 /2019 rstraka 02/11 /2019 Z 12 /20/ 18 Know what's below. Call before you dig. S. GoL10 WA of S f'� �+ j SURVEYED: rm O L D S M ITH z x DESIGNED: BPF, SP LAND DEVELOPMENT SERVICES 24597 DRAWN '9 'w� 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 FAO �GISTVIV_ �w CHECKED 5P T 425 462 1080 F 425 462 7719 www.goldsmi hengineering.com S ONAL >✓BPF, KJG JOB NO. 14134 iCAP RHODY RIDGE, LLC NO. REVISION BY DATE APPR �IPPROVEDKJG SCALE: 1"=40' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY OF RENTON Planning/Building/Public Works Dept. at DATE: RHODODENDRON RIDGE 12/20/18 Q ERP PLAN SET FIELDBOOK: 1977 O PAGE: 27 Q DRAWING NO: O OFF -SITE STORM DRAIN OUTFALL SD-3 = SHEET: OF: 2 6 cz APPROVED FOR CONSTRUCTION m M I O I 0 L LI O V W Z O V Z Q O 0 ♦W V O Z W O 0 O Z SURFACE STANDARD PLAN NOTES: 1 . THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY. 2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF RENTON PLAN REVIEW SECTION AND THE APPLICANT. 3. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE (RMC), THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THIS PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION (E.G. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICAL. ETC.)THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN WITH THE CITY. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. GRADING ACTIVITIES (SITE ALTERATION) ARE LIMITED TO THE HOURS OF 7 A.M. TO 7 P.M. MONDAY THROUGH SATURDAY AND NO WORK ON SUNDAY IS ALLOWED, UNLESS OTHERWISE APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON. 7. IT SHALL BE THE APPLICANT'S/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE INITIATING OFF -SITE WORK. EASEMENTS REQUIRE CITY REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 8. FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS OF CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF RENTON. 9. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 10. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES MUST BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 1 1 . ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95 PERCENT DENSITY, STANDARD PROCTOR. 12. OPEN CUTTING OF EXISTING ROADWAYS FOR NON -FRANCHISED UTILITY OR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY OF RENTON TRENCH RESTORATION STANDARDS. 13. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 14. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. 16. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 17. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE SOLID LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS. 18. BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES. 19. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 20. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 21. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. CITY OF NEWCASTLE, KING COUNTY, WASHINGTON 22. DRAINAGE OUTLETS (STUB -OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR THOSE LOTS APPROVED FOR INFILTRATION BY THE CITY. STUB -OUTS SHALL CONFORM TO THE FOLLOWING: A. EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE DRAINS NECESSARY TO RENDER THE LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE FREE -FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORMWATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE -FOOT -HIGH, 2" X 4" STAKE MARKED C. "STORM" OR "DRAIN". THE STUB -OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND BE SECURED TO THE STAKE. D. PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL AND, IF NON-METALLIC, THE PIPE SHALL BE PLACED IN E. A TRENCH WITH A TRACING WIRE ABOVE OR OTHER ACCEPTABLE DETECTION. F. PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. G. THE APPLICANT/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB -OUT H. CONVEYANCE LINES WITH RESPECT TO OTHER UTILITIES (E.G. POWER, GAS, TELEPHONE, TELEVISION). I. ALL INDIVIDUAL STUB -OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOME OWNER. J. STORM DRAINAGE PIPE SYSTEMS SHALL NOT PENETRATE BUILDING FOUNDATIONS, EXCEPT FOR SUMP PUMP DISCHARGE LINES USED TO DRAIN CRAWL SPACES, PROVIDED THE SUMP PUMP SYSTEM INCLUDES BACKFLOW PREVENTION OR A CHECK VALVE. 23. ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE MUST DEMONSTRATE ONE OF THE FOLLOWING: THE EXISTING DUFF LAYER SHALL BE STAGED AND REDISTRIBUTED TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL, OR; AMENDED SOIL SHALL BE ADDED TO MAINTAIN THE MOISTURE CAPACITY. 24. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS EPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 27. PROJECT LOCATED WITHIN THE AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE SURFACE WATER DESIGN MANUAL AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). EROSION CONTROL NOTES: 1. THESE NOTES SHALL APPEAR FOR ALL PROJECTS - SITE IMPROVEMENTS, SURFACE WATER UTILITY, WASTEWATER UTILITY, WATER UTILITY, AND TRANSPORTATION PLANS: 2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON, PUBLIC WORKS DESIGN ENGINEER. 3. THE BOUNDARIES OF THE CLEARING LIMITS AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY FLAGGED BY SURVEY TAPE OR FENCING IN THE FIELD PRIOR TO CONSTRUCTION IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND OBSERVED DURING CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 4. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. 5. ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITEE. 6. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE PERMITEE SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 7. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR RETENTION FACILITIES. 8. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1 ST TROUGH MARCH 30TH) OR SEVEN DAYS DURING THE DRY SEASON (APRIL 1 ST TOUGH SEPTEMBER 30) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.). 9. WET SEASON SEASONAL EROSION AND SEDIMENT CONTROL REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES CLEARING BETWEEN OCTOBER 1 AND MARCH 30 INCLUSIVE, UNLESS OTHERWISE APPROVED BY THE CITY THROUGH AN ADJUSTMENT PROCESS. 10. COVER MEASURES WILL BE APPLIED IN CONFORMANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL. 1 1 .ANY AREA NEEDING ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 12. THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. 1 3.AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 14.DURING THE TIME PERIOD OF OCTOBER 1 ST THROUGH MARCH 30 TH, ALL PROJECT DISTRIBUTED SOIL AREAS GREATER, THAT ARE TO BE LEFT UN -WORKED FOR MORE THAN 12 HOURS, SHALL BE COVERED BY MULCH, SODDING OR PLASTIC COVERING. 1 5.ANY PERMANENT RETENTION/DETENTION FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE PERMANENT FACILITY IS TO FUNCTION ULTIMATELY AS AN INFILTRATION SYSTEM, THE TEMPORARY FACILITY MUST BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 1 6.PRIOR TO THE BEGINNING OF THE WET SEASON (OCT. 1), ALL DISTURBED AREAS SHALL BE REVIEWED TO IDENTIFY WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. A SKETCH MAP OF THOSE AREAS TO BE SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY OF RENTON FOR REVIEW. 1 7.ALL ESC MEASURES MUST BE REMOVED AFTER CONSTRUCTION ACTIVITY IS COMPLETE. r S Gold of WAS LW�' �� i � � SURVEYEDLN z rm O L D SMITH z x DESIGNED: BPF, SP z LAND DEVELOPMENT SERVICES 424597 DRAWN: +P 9 w� S P Lai 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 �o� �G1sTEg� �`v CHECKED: a T 425 462 1080 F 425 462 7719 www.goldsmi hengineering.com ssIONAL E��1 BPF, KJG JOB NO. 14134 iCAP RHODY RIDGE, LLC NO. REVISION BY DATE APPR rAIM.VEDKJG SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SC ALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM Know what's below. Call before you dig. • CITY OF RENTON Planning/Building/Public Works Dept BY: DATE: CITY OF NEWCASTLE THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO THEIR ACCURACY OR OMISSIONS. R-396604 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING � SURFACE WATER UTILITYAr% IL Justin Johnson 02/11 /2019 rstraka 02/11 /2019 RHODODENDRON RIDGE ERP PLAN SET SURFACE AND EROSION CONTROL STANDARD NOTES DATE: 11/1/18 FIELDBOOK: 1977 PAGE: 27 DRAWING NO: D-6 SHEET: OF: 2 6 (V M O O I L� On - RE H �a O V W Z O V Z O W ♦W V z O 0 W O O Z Y N m 3 0 FRAME AND VANED GRATE 6" OR 12" ONE 9.3 BAR HOOP FOR 6• HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT RECTANGULAR ADJUSTMENT SECTION PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" CPSSP* 12' (STD. SPEC. 9-0520) SOLID WALL PVC 15' (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15" (STD. SPEC. 9-05.12(2)) iF CORRUGATED POLYETHYLENE STORM SEWER PIPE lgfbE �eJ NOTES pN A � to the rebar shown in the PRECAST BASE SECTION, fibers alternatives 1. As acceptable d a according to the Standard Specifications), or (placed wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. #3 BAR EACH CORNER _ #3 BAR EACH SIDE #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR EACH CORNER 18" MIN #3 BAR HOOP 2. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4. The frame and grate must be installed with the flange down. 5. The Precast Base Section may have a rounded floor, and the walls may Y be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the precast base section. 7. All pickup holes shall be routed full after the basin has been laced. P P 9 p 8. All grade rings and castings shall be set in mortar in accordance with Standard Specification 9-04.3. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION STD. PLAN - 200.00 PUBLIC WORKS CATCH BASIN TYPE 1 DEPARTMENT MARCH 2O08 24" a N N z �a Z g W Co 1 m tt BOLT -DOWN SLOT -SEE DETAIL AND NOTE 1 J 40 A J O�OOOp O�a�aQO 0�0�040Q QOOQQ�Q�Q O O O O O B TOP 4 3/4" L T =-7-,'R -SEE NOTE 2 SECTION O 5" 3 1/2" 1/2 ,3/4" 5/8 3/4" 4 �-� -- 314" DIAM. HOLE 1 1/4" 1 1/2• 10 DIAM. HANDLE SECTION O BOLT -DOWN SLOT DETAIL SEE NOTE 1 SECTION OB NOTES 1 Provide two slots in the cover that are vertically aligned with the holes in the frame.Location of bolt -down slots varies among different manufacturers. 2. Alternative reinforcing designs are acceptable in lieu of the rib design. 3. Refer to Standard Specification 9-05.15(2) for additional requirements 4. For Frame details, see City of Renton Standard Plan 204.00. ISOMETRIC PUBLIC WORKS RECTANGULAR SOLID STD. PLAN - 204.10 DEPARTMENT METAL COVER MARCH 2O08 GOLDSMITH LAND DEVELOPMENT SERVICES w 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 a T 425 462 1080 F 425 462 7719 www.goldsmithengineering.com JOB NO. 14134 iCAP RHODY RIDGE, LLC 11/1/18 1 • Gold of WAS w j 14,7 1 z x 24597 �04� GISTEg�'9 SSIONAL St O 0 6 0 \ CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) HANDHOLD �g5 Z RECTANGULAR ADJUSTMENT SECTION 2 OR CIRCULAR ADJUSTMENT SECTION m v GROUT, TYPICAL (SEE NOTE 5) FLAT SLAB TOP 46', 54", 60', 72', 84" OR 96" MORTAR (TYP.) STEPS ER LADDER 'ILLET N REINFORCING STEEL (TYP-) \ b 12' GRAVEL BACKFILL FOR . , PIPE ZONE BEDDING e• SEPARATE BASE INTEGRAL BASE CAST -IN -PLACE PRECAST WITH RISER WRING 1r GRAVEL BACKFILL FOR 8T - PIPE ZONE BEDDING J� SEPARATE BASE PRECAST SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS BASE REINFORCING STEEL in2fft IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE 48' 4• 6" 36" 8" 0.23 0.15 54' 4.5" 8" 42• 8• 0.19 0.19 so, 5" 8" 48" 8" 0.25 0.25 72" e" 8" 60" 12" 0.35 0.24 84• 1 8" 1 12" 1 72" 1 12" 0.39 1 0.29 9e• 1 8" 12" 1 84" 1 IT 0.39 0.29 NOTES I. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning. 3. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 5 All d d f h II b t' ' rd •th PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER BASIN DIAMETER CONCRETE ALL METAL CPSSP O SOLID WALL Pvc 20 PROFILE WALL Pvc p 48• 24' M. 24" 27' 30' 54" 30" 36" 30" 27" 36" 60" 36" 42" N. 3W 42' 72" 42' 54' 42" 36• 48" 84" 54" 60" 54" 36' 48" N' Bo" 72" 60" 36' 48' gra a nngS, users, an Cas ngS S a e Se In m0 rta r In aCCO ance WI Standard Specification 9-04.3. 8 (Bid. Spec. 9-0. Corrugated 511)) Polyethylene Storm 9-0 Sewer Pipe (Std. Spec. (Sid. Spec. 9-05.12(2)) Y PUBLIC WORKS CATCH BASIN TYPE 2 PLAN - 201.00 DEPARTMENT �N tp MARCH 2O08 �''•Illl>•�I�Ibr. 1"�44, 11r [13mm] LETTERING BOLTHOLES - 3 PLCS EQUALLY SPACED 120" APART ON 231116" (586mm) DIA B.C. q 3 RENTON AHEAD OF THE CURVE DRAIN (1)1" (25mm) DIA PICKHOLE ® 1 1/4• [32mml LETTERING PLAN VIEW 25• DIA. [635mm] 1' r [25mm] 3/4' +L1li [19mm] 9 3/a 2112 -# Immrn] [64mm1 TYP COVER SECTION VIEW 26 1/2" DIA [673mm] 25 1/4" DIA [641mm] 1 1/18" "4. (Bmm) DIA [27mm] NEOPRENE GASKET 11 1T [752mm8"] J 5/8" 23 3/8" DIA CL OPEN [16mm] [594mm] 27 5/16" DIA [694mm] 34 1/8" DIA [867mm] FRAME SECTION VIEW COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 58r'-11 x 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4" 1 1I18" [Bmm] _ [27mm] 1/8• 1T [3mm] 1/8' [R3mm] GASKET GROOVE DETAIL NOTES ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRON WORKS INC. No. 3717C1 OR APPROVED EQUAL. aj PUBLIC WORKS STORM ROUND FRAME AND COVER STD. PLAN - 204.50 �N CCU DEPARTMENT MARCH 2O08 NO. REVISION DF NEWCASTLE, KING COUNTY, WASHINGTON 0 FRAME AND VANED GRATE CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE GROUTED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION. BASE SECTION NOTES SEE NOTE 4 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO GROUT IN PLACE IN ACCORDANCE WITH APWA STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT, 4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR j2 BOND. 5, ADJUSTMENT SECTION SHALL BE GROUTED WATERTIGHT TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH NONSHRINK GROUT 6. GROUTING BETWEEN ADJUSTMENT SECTION SHALL BE WATER TIGHT. 7. GROUT IS TO BE NON -SHRINK TYPE GROUT MEETING THE REQUIREMENTS OF ASTM 157 PER APWA STANDARD SPECIFICATION 9-20.3 FOR MAXIMUM PERCENT DRY SHRINKAGE. THE MINIMUM COMPRESSIVE STRENGTH SHALL BE 4,000 PSI AT 7 DAY PER APWA STANDARD SPECIFICATION 9-20.3 8. PICK I LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. PUBLIC WORKS CATCsA CASUM INSTALLATION STD. PLAN - 202.00 DEPARTMENT MARCH 2O08 #6 BARS @ 7" SPACING 24" DIAM., 48" DIAM. OR 54" DIAM. HOLE 2" (TYP.) r 12 1' MIN. 1/2'MAX. 8W* or 86" FLAT SLAB TOP A�i #5 BARS @ 6" SPACING 20" x 24", 24" DIAM., 48" DIAM. OR 54" DIAM. HOLE 2" (4411"MIN. TYPICAL ORIENTATION J- FOR ACCESS AND STEPS m 2 1/2" MAX. 72" FLAT SLAB TOP 2� #4 BARS @ 6" SPACING a 20' x 24" OR 24" DIAM. HOLE 2"(TYP.) ''• -�'-. t' 48" MIN. V MIN. 2112" MAX. ECCENTRIC CONE SECTION 48", 54", or 60" FLAT SLAB TOP 12" (TYP.) M a 6" to 12" PREFABRICATED LADDER 12" MIN. �s STEP 6" OR 12" <�CINE #3 BAR HOOP ONE #3 BAR HOOP FOR 6" 0 4" S• TWO #3 BAR HOOPS FOR 12" CIRCULAR ADJUSTMENT SECTION RECTANGULAR ADJUSTMENT SECTION 1.0 As an acceptable alternative to rebar, wire mesh having a minimum area of 0.12 square inches per foot may be used for adjustment sections. PUBLIC WORKS MISCELLANEOUS DETAILS FOR STD. PLAN - 204.80 DEPARTMENT DRAINAGE STRUCTURES "A�N,fp MARCH 2O08 SURVEYED: LN DESIGNED: BPF, SP DRAWN: SP CHECKED: BPF, KJG BY DATE APPR APPROVED: KJ G SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 29114" N r BOLT -DOWN HOLE (TYP.) 5W -11 NC, SEE DETAIL & NOTE 2 O APPROVED FOR CONSTRUCTION BY: DATE: - CITY OF NEWCASTLE THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO THEIR ACCURACY OR OMISSIONS. NOTES TOP 1• This frame is designed to accommodate 20" x 24" grates or covers 2. Provide two holes in the frame that are vertically aligned with t he grate or cover slots. Tap each hole to accept 241/4' a 5/8' - 11 NC x 2" alien head cap screw. Location of bolt down holes varies among different e manufacturers. 3. Refer to Standard Specification 9-05.15(2) for additional 4. requirements. SECTION A RECESSED ALLEN HEAD CAP SCREW 718" 1/8. 5/8"-11 NCx2" II�{I 3/4" GRATE a � 1 5fir 2 1/2' SECTION BOLT -DOWN DETAIL DETAIL O SEE NOTE p�PUBLIC WORKS RECTANGULAR FRAME $ DEPARTMENT N'C S 9 I, 12 Smooth Coupling Band for Smooth Pipe material to be 3" ASTM A plate galvanized I I after fabrics ion per ASTM A 123 r 4.1 slots to be all holes 119/sz x• a -Y4" diam. �� 1 7" coupling bend 4" STD. PLAN - 204.00 MARCH 2O08 Pipe stakes I LJ 049 On u� u^ r-1 �a 4z 12" I � O Plate Detail coupling band NOTE: ♦ ` 1. The smooth coupling band shall be used in v 1„ collar (2" pipe) combination with concrete pipe. UJ 2. Concrete pipe without bell and spigot shall not be installed on grades in excess of 20%. weld weld 3. The first anchor shall be installed on the first Z plate (see detail) section of the lower end of the pipe and remaining anchors evenly spaced throughout the installation. material to be ASTM O 4. If the pipe being installed has a manhole or A 36 galvanized after p catch basin on the lower end of the pipe, the 1 )" x 6' pipe stakes fabrication per ASTM p each side of culvert A 153 first pipe anchor may be eliminated. v 5. When CMP is used, the anchors may be attached to the coupling bands used tojoin flatten to point the pipe as long as the specified spacing is Anchor Assembly not exceeded. Corrugated Metal Pipe 6. All pipe anchors shall be securely installed before backfilling around the pipe. R-396605 � PUBLIC WORKS `�•`•` ` DETAILS FOR COUPLING BANDS STD. PLAN - 221.20 MARCH 2O08 DEPARTMENT "AWN FOR CORRUGATED METAL PIPES t 0 `/ W IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 DEVELOPMENT ENGINEERING 1• SURFACE WATER UTILITY Justin Johnson 02/11/2019 rstraka 02/11/2019 Z CITY OF RHODODENDRON RIDGE DATE 11/1/18 Q RENTON ERP PLAN SET 27 Y FIELDBOOK: 1 9 7 7 Y PAGE: 7 / / Q DRAWING NO: O Planning/Building/Public Works Dept. STORM DRAINAGE DETAILS D-7 SHEET: OF: 2 6 SE 1 /4, SE 1 /4 SECTION 29, TOWNSHIP 24 N, RANGE 5 E, W.M. CITY OF NEWCASTLE. KING COUNTY. WASHINGTON 0) rrn O W I- limits of pipe compaction grave for pipe „e.­�y A. Metal and Concrete limits of pipe Dmpaction o" 0.15 O.D. min. 35 O.D. min. specified 3' max •� 0.15 rise min. limits of pipe compaction 65 rise min. gravel backill gravel backfill for for pipe betltling foundations when specified B. Pipe - Arch Installation Rigid Pipe NOTES: 1. Pipe compaction limits shown on this plan are for pipe construction in an embankment. For pipe construction in a trench, the horizontal limits of the pipe compaction zone shall be the walls of the trench. 2. All steel and aluminum pipe and pipe -arches shall be installed in accordance with design A. 3. Concrete pipe with elliptical reinforcement shall be installed in accordance with design A. 4. Concrete pipe, plain or with circular reinforcement, shall be installed with design A. 5. O.D. is equal to the outside diameter of a pipe or the outside span of pipe -arch. The dimensions shown as O.D. with 3' maximum shall be O.D. until O.D. equals 3; at which point T shall be used. VFW for diameters 12" through 42" and spans through 50". 2'-0" for diameters greater than 42" and spans greater than 50". W (see note 4) limit of pipe zone bedding material b for flexible pipe (see note 6) m O.D. foundafion level " A = 4" min. 27" I.D. and under 6" min., over 27" I.D. Bedding for Flexible Pipe Flexible Pipe NOTES: 1. Provide uniform support under barrels. 2. Hand tamp under haunches. 3. Compact bedding material to 95% max. density; directly over pipe, hand tamp only. 4. See "Excavation and Preparation of Trench" in sanitary sewers section of the standard WSDOT/APWA specifications for trench width "W" and trenching Options. The pipe zone will be the actual trench width. The minimum concrete width shall be 11 I.D. = 18". 5. Trench backfill shall conform to "Backfilling Sewer Trenches" in the sanitary sewers section of the WSDOT/APWA standard specifications, except that rocks or lumps larger than 1" per foot of pipe diameter shall not be used in the backfill material. 6. See "Bedding Material for Flexible Pipe" in aggregates section of the WSDOT/APWA standard speciflceflons for the material specifications. ®Backfill material placed in 0.5' loose layers and compacted to 95% maximum density. Method B or C compaction (WSDOT/APWA) standard specifications.) Pipe Size Min. dist. between barrels circular pipe conic., LCPE, CMP (diameter) 12" to 24" 12" 30" to 96" diam. / 2 102" to 180" 48" pipe - arch metal only (span) 18" to 36" 12" 43" to 142" span / 3 148" to 199" 48" ti�Y o STD. PLAN - 220.00 PUBLIC WORKS PIPE COMPACTION DEPARTMENT DESIGN AND BACKFILL MARCH 2O08 GOLDSMITH LAND DEVELOPMENT SERVICES w 1215 1 14th Ave SE, Bellevue, WA 98004 1 PO Box 3565, Bellevue, WA 98009 a T 425 462 1080 F 425 462 7719 www.goldsmithengineering.com JOB NO. 14134 iCAP RHODY RIDGE, LLC 11/1/18 1 " G OLd OF WAS w j .14 1 z x 24597 BOA �GIS'TEg�'9 SSIONAL ECG STANDARD STRENGTH CATCH BASIN 1. CONDITION OF USE 1.1. SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCHBASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 1.2. MAY BE USED ANYWHERE AT THE APPLICANT'S DISCRETION TO PROTECT DRAINAGE SYSTEM. 1.3. THE CONTRIBUTING DRAINAGE AREA MOST NOT BE LARGER THAN 1 ACRE. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. FILTER FABRIC IS ONLY ALLOWED WERE PONDING WILL NOT BE A TRAFFIC CONCERN AND WHERE SLOPE EROSION WILL NOT RESULT IF THE CURB IS OVERTOPPED BY PONDED WATER. 2.2. THE PLACEMENT OF A FILTER FABRIC UNDER GRATES IS GENERALLY PROHIBITED AND THE USE OF FILTER FABRIC OVER GRATES IS STRICTLY LIMITED AND DISCOURAGED. 3. MAINTENANCE STANDARDS 3.1. ANY ACCUMULATED SEDIMENT ON OR AROUND INLET PROTECTION SHALL BE REMOVED IMMEDIATELY. SEDIMENT SHALL NOT BE REMOVED WITH WATER AND ALL SEDIMENT MUST BE DISPOSED OF AS FILL ON SITE OR HAULED OFF SITE. TY PUBLIC WORKS DEPARTMENT FILTER FABRIC PROTECTION STD. PLAN - 216.20 MARCH 2O08 JOINTS IN FILTER FABRIC SHALL BE SPLICED a AT POSTS. USE STAPLES, WIRE RINGS, OR 2"x2" BY 14 Ga. WIRE OR y EQUIVALENT TO ATTACH FABRIC TO POSTS. EQUIVALENT, IF STANDARD z STRENGTH FABRIC USED --- :�� 7 FILTER FABRIC o mnn. POST SPACING MAY BE INCREASED TO V E WIRE BACKING IS USED MINIMUM 4"x4" TRENCH BACKFILL TRENCH WITH NATIVE SOIL 27r4" WOOD POSTS, STEEL FENCE / POSTS, REBAR, OR EQUIVALENT 2 NOTES 1. CONDITION OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. 30-1005IEVESIZE (0.60-Q15MM)FORSILTFILM A05 (ASTM 34751) 50-10051EVE SIZE 0.30-015MM FOR OTHER FABRICS WATER PERMITTIVITY ASTM D491 M02SECA-1 MINIMUM GRAB TENSILE STRENCHr (ASTM D4532) 180 LBS. MI N. FOR EXTRA STRENGH FABRIC 100 LBS. MI N. FOR STANDARD STRENGHT FABRIC GRAB TENSI LE ELONGATION ASTM D4632 30%MAX. ULTRAVIOLATE RESISTANCE(ASTM D4355) 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1 V 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE S WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. 3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. T IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. 3A SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTE)CTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. STD. PLAN - 214.00 PUBLIC WORKS SILT FENCE DEPARTMENT MARCH 2O08 NO. REVISION DRAINAGE GRATE GRATEFRAME v � SEDIMENTAND DEBRIS o• D FILTERED( WATER r RIM kt> OVERFLOW BYPASS BELOW INLET GRATE DEVICE 4 � SECTION VIEW DRAINAGE GRATE RECTANGULAR GRATE SHOWN un BELOW INLET GRATE DEVICE RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) ISOMETRIC VIEW NOTES 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service. 2. The BIGD shall have a built-in high -flow relief system (overflow bypass). 3. The retrieval system must allow removal of the BIGD without spilling the collected material. 4. Perform maintenance in accordance with Standard Specification 8-01.3(15). ��Y STD. PLAN - 216.30 PUBLIC WORKS CATCH BASIN FILTER '' DEPARTMENT N2 MARCH 2O08 3 m SILT FENCE 3 TOP OF FABRIC ` BELT ' TOP 8" FLOW 1 100% COMPACTION EACH SIDE DIAGONAL ATTACHMENT DOUBLES STRENGTH NOTES: 1. POST SPACING: T MAX. ON OPEN RUNS 4' MAX. ON POOLING AREAS. 2. POST DEPTH: AS MUCH BELOW GROUND AS FABRIC ABOVE GROUND. 3. PONDING HEIGHT MAX. 24" ATTACH FABRIC TO UPSTREAM SIDE OF POST. 4. DRIVE OVER EACH SIDE OF SILT FENCE 2 TO 4 TIMES WITH DEVICE EXERTING 60 P.S.I. OR GREATER. 5. NO MORE THAN 24" OF A 36" FABRIC S ALLOWED ABOVE GROUND. 6. VIBRATORY PLOW IS NOT ACCEPTABLE BECAUSE OF HORIZONTAL COMPACTION. ­Z3OPERATION HORIZONTAL CHISEL POINT (76mm WIDTH) ATTACHMENT DETAILS: 1. GATHER FABRIC AT POSTS, IF NEEDED. 2. UTILIZE THREE TIES PER POST, ALL WITHIN TOP 8" OF FABRIC. 3. POSITION EACH TIE DIAGONALLY, PUNCTURING HOLES VERTICALLY A MINIMUM OF V APART. 4. HANG EACH TIE ON A POST NIPPLE AND TIGHTEN SECURELY. USE CABLE TIES (50 LBS) OF SOFT WIRE. ROLL OF SILT FENCE 200-300mm STD. PLAN - 214.10 PUBLIC WORKS SILT FENCE INSTALLATION DEPARTMENT BY SLICING MARCH 2O08 SURVEYED: LN DESIGNED: BPF, SP DRAWN: SP CHECKED: BPF, KJG BY DATE APPR APPROVED: KJ G SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM SPECIAL NOTE: IN THE EVENT TRANSVERSE PATCHES EXIST WITHIN THE AFFECTED STREET, THE LENGTH OF THE PATCH SHALL BE EXTENDED TO INCLUDE ANY EXISTING PATCH WITHIN 10 FEET OF THE EDGE OF THE PATCH REQUIRED FOR THE NEW CROSSING AND ANY SUBSEQUENT PATCH EDGE WITHIN 10 FEET OF THE EDGE OF THE SECOND PATCH AND SO ON UP TO A TOTAL OF 300 FEET. APPROVED FOR CONSTRUCTION BY: DATE: - CITY OF NEWCASTLE THESE DRAWINGS ARE APPROVED FOR CONSTRUCTION FOR A PERIOD OF 12 MONTHS FROM THE DATE SHOWN HEREON. THE CITY RESERVES THE RIGHT TO MAKE REVISIONS, ADDITIONS, DELETIONS, OR MODIFICATIONS SHOULD CONSTRUCTION BE DELAYED BEYOND THIS TIME LIMITATION. THE CITY, BY APPROVING THESE DRAWINGS, ASSUMES NO LIABILITY IN REGARDS TO THEIR ACCURACY OR OMISSIONS. 1' 1' VARIES 1' 1' MIN I MIN MIN I MIN T_V ,. �v .•.I:_ .��:: L r� I i .Ii �•, TRAFFIC FLOW •t , I' i I 2" HMA I #•.'. 2" TO 8" HMA I. 4 I 6.5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES: 6.5' MIN. MIN j MIN VARIES MIN I MIN FACE OF GUTTER OR EDGE OF PAVEMENT CENTER LINE OR LANE LINE DEPTH OF EXISTING PAVEMENT ! 2" SAWCUT AND REMOVE OR PLANE, SEAL WITH 2" - 6" MIN. HMA (SEE NOTE 2) AR-4000W I . (EACH SIDE) 6" CRUSHED SURFACING TOP COURSE (CSTC) 2" HMA PER WSDOT STANDARD SPE� FICATIONS, COMPACTED TO 95X MODIFIED PROCTOR, SAWCUT AFTER BACKFILL \-CSTC, (EACH SIDE) BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19). GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO 95% MODIFIED PROCTOR. WIDTH OF TRENCH AS REQUIRED BY SIZE OF PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF NEEDED, SHALL MEET THE REQUIREMENTS OF WSDOT PIPE ZONE BEDDING. MATERIAL- SEE STANDARD STANDARD SPECIFICATION 7-08.3(1)B PLAN 110.1. TRENCH WIDTH FOR NOTES, SEE STANDARD PLAN 110.1 TYPICAL TRANSVERSE PATCH FOR STD" PLAN - 110 is PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID PPFz ED DEPARTMENT PAVEMENT WITH OVERLAY 77 �8u -ram AN Know what's below. Call before you dig. AwtbL CITY OF RENTON Planning/Building/Public Works Dept. 1 u� �a z 0 W Z Z O V Z R-396606co ° IN COMPLIANCE WITH CITY OF RENTON STANDARDS W 0 DEVELOPMENT ENGINEERING SURFACE WATER UTILITY Justin Johnson 02/11 /2019 rstraka 02/11 /2019 Z O 0 DATE: W RHODODENDRON RIDGE 11/1/18 0 PAGE: � 7 / / ERP PLAN SET OOK 1777 O PAGE: Q DRAWING NO: O STORM DRAINAGE DETAILS D-8 _ SHEET: OF: 2 6