HomeMy WebLinkAboutR-405627m I 0 W I U Z 0 Q I u 0 3 0 I 0 E 0 0 0 N co 75 a U O a Q 0 m J 0 0 N 0 I 0 11:1111J11milm', GROUND CABLE CONNECTION GROUND ROD CONNECTION 1, GROUND CABLE PIGTAIL, THERMOWELD AT GROUND CABLE OR AT INSULATED GROUND BAR G GROUND CABLE (UNDERGROUND) OR INSULATED GROUND BUS BAR POWER ® PANELBOARD, 208Y/12OV, 3 PHASE, 4 WIRE ® PANELBOARD, 480V, 3 PHASE, 3 WIRE OR 480/277V, 30, 4 WIRE 1111111010009y1Mr_T410 k 120V, 15A, 1 PHASE, 2 POLE, 3 WIRE RECEPTACLE, NEMA 5-15R, HUBBELL #5262 321: 120V, 15A, 1 PHASE, 2 POLE, 3 WIRE, DUPLEX CORD DROP RECEPTACLE, NEMA 5-15R, HUBBELL #5262 p�20 120V, 20A, 1 PHASE, 2 POLE, 3 WIRE, RECEPTACLE, NEMA 5-20R, HUBBELL #5362 30 120V, 30A, 1 PHASE, 2 POLE, 3 WIRE, TWISTLOCK RECEPTACLE, NEMA L5-30R, HUBBELL #2610A p 120V, 15A, 1 PHASE, 2 POLE, 3 WIRE DOUBLE DUPLEX RECEPTACLE, NEMA 5-15R, HUBBELL #5262 o SPECIAL PANELBOARD, TYPE AS NOTED ❑J UNFUSED DISCONNECT SWITCH 30/NF SWITCH RATING IZ' FUSED DISCONNECT SWITCH 30/20 SWITCH RATING/FUSE RATING IZ' MOTOR STARTER (COMBINATION) ® CIRCUIT BREAKER IN ENCLOSURE - SIZE AS SHOWN ® MOTOR STARTER (MANUAL) T❑ TRANSFORMER (SIZE AS SHOWN, IN KVA) PB PULL BOX Q JUNCTION BOX O 460 VOLT MOTOR (SIZE AS NOTED) �O 208 VOLT OR 240 V MOTOR (SIZE AS NOTED) 115 VOLT MOTOR (SIZE AS NOTED) sV SOLENOID VALVE CONDUIT SURFACE MOUNTED OR CONCEALED. E CONDUIT IN WALL OR CEILING SPACE. CONTAINS ONE AWG #12 PHASE, AND ONE AWG #12 NEUTRAL CONDUCTOR UNLESS OTHERWISE NOTED. "E" INDICATES EMERGENCY CIRCUIT. --------- CONDUIT UNDERGROUND, UNDER FLOOR SLAB, OR IN CEILING SPACE OF FLOOR BELOW WITH CONDUCTORS AS ABOVE. \___C.O. CONDUIT ONLY. FLEXIBLE METAL CONDUIT. PROVIDE CIRCUIT CONDUCTORS REQUIRED BASED ON 60 DEGREE CELCIUS CONDUCTOR RATING. .a 30 208V, 30A, 1 PHASE, 2 WIRE, 3 POLE, CORD DROP WITH TWISTLOCK, NEMA L6-30R, HUBBELL #2623 m 30 480V, 30A, 3 PHASE, 4 POLE, 3 WIRE GROUND THROUGH EXTRA POLE. CROUSE HINDS #ARE 3423 VICE WP 15A, 125V, DUPLEX IN A WEATHERPROOF ENCLOSURE (NEMA 3R RAINTIGHT) I:1a GFI 15A, 125V, DUPLEX WITH BUILT IN GROUND FAULT CIRCUIT INTERRUPTER, HUBBELL GF52621 ® FLOOR BOX WITH 20A 120V FOURPLEX AND DATA COMPARTMENT HO 208V, 20A, 1 PHASE, 2 POLE, 3 WIRE, TWISTLOCK RECEPTACLE, NEMA L6-30R, HUBBELL #2320A 502 NEMA 14-50R STRAIGHT BLADE, 120/208V, 10, 3-POLE, 4-WIRE RECEPTACLE, 50A. COMMUNICATIONS i TELEPHONE OUTLET SZ DATA OUTLET DATA/TELEPHONE OUTLET iW WALL MOUNTED OUTLET SEE DETAIL 1 SHEET E549 �T TELEPHONE CONDUIT HOMERUN TO TELEPHONE BACKBOARD PA PUBLIC ADDRESS WIRE RACEWAY sO PAGING SPEAKER, CEILING MOUNTED vO VOLUME CONTROL sOV PAGING SPEAKER, CEILING MOUNTED WITH VOLUME CONTROL 04 SECURITY CAMERA FIRE DETECTION INDICATES PHASE CONDUCTOR (#12 OR SIZE AS NOTED) INDICATES NEUTRAL CONDUCTOR (#12 OR SIZE AS NOTED) \ INDICATES GROUND CONDUCTOR (#12 OR SIZE AS NOTED) INDICATES ISOLATED GREEN GROUND CONDUCTOR (#12 OR SIZE AS NOTED) #10 HOMERUN W/7#10 SHOWING CIRCUIT SOURCE (PANEL/PANEL POSITION) 1 D 6 - 1 /1,3,5,7 HOMERUN W/CIRCUIT SOURCE & CONDUIT & 1 B2-8/1,3,5 WIRE SIZE NOTED 1-1 /2"C,3#2+#2/ON+2#8G CONDUIT TURNS DOWN 0 CONDUIT TURNS UP EQUIPMENT OR MATERIALS TO BE DISCONNECTED AND REMOVED Q TAP BOX 0❑ MANHOLE © HEAT DETECTOR 0 SMOKE DETECTOR ® FIRE ALARM TRANSMITTER PANEL (ADT) pg PULL STATION A HORN/STROBE ANNUNCIATOR EK HORN ANNUNCIATOR LIGHTING REFER TO SHEET E500 FOR DETAILED FIXTURE SCHEDULE WITH SYMBOLS 0 LIGHT FIXTURE - SHADED CONNECTED TO EMERGENCY CIRCUIT I� EXIT SIGN, WALL MOUNTED. DIRECTIONAL ARROW SHOWN ® EXIT SIGN, CEILING MOUNTED. DIRECTIONAL ARROW SHOWN X FIXTURE IDENTIFICATION Y 'Y' DENOTES FIXTURE TYPE "Y" DENOTES WATTAGE OF FIXTURE SWITCH LEG IF USED a LCP RELAY IDENTIFICATION r (-) INDICATES FIXTURE WIRED TO "HOT" 1,R3 AND IS UNCONTROLLED BRANCH CIRCUIT GROUP FOR REFERENCE. USE EXISTING CIRCUITS AND GROUP AS SHOWN. AS -BUILT FINAL CIRCUIT NUMBERS. $ $ 3 $ 4 TOGGLE SWITCHES - LINE VOLTAGE, SINGLE POLE/ 3-WAY/ 4-WAY. NUMBER OF SWITCHES UNDER COMMON PLATE a,b,c LOWER CASE LETTER INDICATES SWITCHING GROUP R12,R13 LOW -VOLTAGE LIGHTING CONTROL "R12,R13" SWITCH. INDICATES ONE SWITCH $`� CONNECTED TO LCP RELAYS 12 AND 13 REFERENCE SHEET E503 AND E504, DETAIL 1. $m MOTION SENSOR SWITCH CONTROL SEE DETAIL 6 SHEET E502 $ ° INCANDESCENT DIMMER SWITCH Q CEILING MOUNTED MOTION SENSOR SEE DETAILS 3,4,AND 5 SHEET E502 © POWER PACK FOR CEILING MOUNTED SENSOR SEE DETAIL 4 AND 5 SHEET E502 PHOTOELECTRIC CELL EXISTING 1' BY 4' INDUSTRIAL FIXTURE ON © EMERGENCY CIRCUIT UNLESS OTHERWISE NOTED. EXISTING 1' BY 8' INDUSTRIAL FIXTURE ON E EMERGENCY CIRCUIT UNLESS OTHERWISE NOTED. 0 FIXTURE TYPE �o UNLESS OTHERWISE NOTED. ® FIXTURE TYPE 49 UNLESS OTHERWISE NOTED. FIXTURE TYPE 31 UNLESS OTHERWISE NOTED. ® FIXTURE TYPE 45 UNLESS OTHERWISE NOTED. b,& FIXTURE TYPE "b" INDICATES SWITCH CONTROL. a0 FIXTURE TYPE 10o a" INDICATES SWITCH CONTROL. SCHEMATIC I __o 0- -.0-1 ko- SINGE LINE DISCONNECT SWITCH CIRCUIT BREAKER TRANSFORMER GROUND CONNECTION PILOT LIGHT * INDICATES COLOR PUSHBUTTON MOMENTARY CONTACT NORMALLY OPEN PUSHBUTTON MOMENTARY CONTACT NORMALLY CLOSED SOLENOID VALVE RELAYS & COILS *=TYPE M=MOTOR STARTER CR=CONTROL RELAY C=CONTACTOR TR=TIME DELAY OR TIMING RELAY N.O. CONTACT N.C. CONTACT AMMETER AMMETER SWITCH VOLTMETER VOLTMETER SWITCH TEST BLOCK 15KV IN -LINE SPLICE FUSE (RATING, TYPE) 4V02-2H8 I50A M. BK . 3PH, 3W 2V02-2H8 IOOA M. BK . 3PH, 4W 3V02-1J8 225A BUS 100A MC TRANSFORMER (DASHED LINE INDICATES ELECTROSTATIC SHIELD) 480V, 3PH, 3W PANELBOARD (RATINGS AS NOTED) 208Y/12OV, 3PH, 4W PANELBOARD (RATINGS AS NOTED) 480Y/277V, 3PH, 4W LIGHTING PANELBOARD (RATINGS AS NOTED) COMBINATION STARTER 3A CONTROLLER OR MCC CUBICLE NUMBER T� 2 STARTER SIZE DISCONNECT SWITCH MOTOR HORSEPOWER GENERAL NOTES ❑� INSTANTANEOUS OVERCURRENT PROTECTION FUNCTION 1. LOW VOLTAGE CONDUCTORS SHALL BE THHN FOR INTERIOR LOCATIONS AND XHHW FOR OUTDOOR AND BELOW GRADE ST SHORT TIME OVERCURRENT PROTECTION INSTALLATIONS. UL LISTED. FUNCTION LT LONG TIME OVERCURRENT PROTECTION 2. MEDIUM VOLTAGE CONDUCTORS SHALL BE MV-105, 133%, FUNCTION EPR, SHIELDED. UL LISTED GF GROUND FAULT OVERCURRENT PROTECTION 3. ALL PRECAST MANHOLES AND HANDHOLES SHALL BE FUNCTION SUPPLIED BY UTILITY VAULT CO/OLDCASTLE, OR APPROVED EQUAL. �K KEY INTERLOCK 4. MEDIUM VOLTAGE SPLICES SHALL UTILIZE DEAD BREAK, OE ELECTRICAL OPERATOR SEPARABLE, WATERPROOF T-BODY CONNECTORS. ELASTIMOLD, OR APPROVED EQUAL. UL LISTED MI MAIN BUS &BREAKER MONITORING & CONTROL UNIT 5. UNDERGROUND CONDUIT FOR DIRECT BURIAL APPLICATIONS SHALL BE SHALL BE PVC SCHEDULE 80. PVC SCHEDULE M2 BREAKER MONITORING & CONTROL UNIT 40 SHALL BE USED FOR CONCRETE AND FTB ENCASED UNDERGROUND DUCTS. UL LISTED NETWORK TERMINATION 6. BORED UNDERGROUND CONDUIT SHALL BE HDPE TYPE, UL LISTED. CARLON, CANTEX OR APPROVED PAS/AF FUSE DISCONNECT SWITCH 7. REPAIR OR REPLACE ANY AND ALL PAVEMENT AND LANDSCAPING DISTURBED DURING CONSTRUCTION IN ACCORDANCE WITH C501 AND THE SPECIFICATIONS. 8. CONTRACTOR SHALL SUBMIT BORING PLANS AND PROFILES TO DESIGN TEAM FOR APPROVAL PRIOR TO MOBILIZING. 9. CONTRACTOR SHALL PROVIDE THROUGH LOCATE SERVICE FOR ALL AREA'S IN BORE OR TRENCH PATH. 10. CONTRACTOR SHALL PERFORM TAN -DELTA CABLE TESTING, USING A KV LEVEL BETWEEN 1.5 AND 2 TIMES THE SYSTEM VOLTAGE, ON ALL EXISTING MEDIUM VOLTAGE FEEDER CABLES SECTIONS THAT HAVE BEEN MODIFIED AS PART OF THIS SCOPE OF WORK. ABBREVIATIONS A,AMP AMPERE M METER AC AIR COMPRESSOR, ALTERNATING MCC MOTOR CONTROL CENTER CURRENT AF AMPERE FRAME MCP MAIN CONTROL PANEL AFF ABOVE FINISHED FLOOR MFGR MANUFACTURER Al ANALOG INPUT POINT (PLC) MH MANHOLE AIC AMPERES INTERRUPTING CAPACITY MMU MOTOR MONITORING UNIT AIL AMBER INDICATING LIGHT MOV MOTOR OPERATED VALVE AL ALARM MS MOTOR STARTER MTS MANUAL TRANSFER SWITCH ALT ALTERNATOR N NEUTRAL AM AMMETER NC NORMALLY CLOSED AO ANALOG OUTPUT POINT (PLC) NF NON FUSED AOR HANDS OFF REMOTE NO NORMALLY OPEN AWC AMPERES WITHSTAND CAPACITY 01 OPERATOR INTERFACE AS AMPERE SWITCH OIT OPERATOR IN TROUBLE AT AMPERE TRIP OL OVERLOAD RELAY ATS AUTOMATIC TRANSFER SWITCH OT OVER TEMP BAT BATTERY P POWER, PUMP BC BATTERY CHARGER P.S. PUMP STATION BFV BUTTERFLY VALVE PB PUSH BUTTON - LIGHTED BH BLOCK HEATER PBL PUSH BUTTON - LIGHTED BIL BLUE INDICATING LIGHT PC PARTICLE COUNTER BP BYPASS CONTRACTOR PE PHOTO ELECTRIC RELAY C CONDUIT, CONTROL PFR PHASE FAILURE RELAY CAP CAPACITOR PCS POLYVINYL CHLORIDE CB CIRCUIT BREAKER COATED GRS (CONDUIT) CKT CIRCUIT PLC PROGRAMMABLE LOGIC CNT START COUNTER CONTROLLER CONT CONTINUED PMD POWER MONITORING DEVICE CP CONTROL PANEL PNL PANEL CPT CONTROL POWER TRANSFORMER POT POTENTIOMETER CR CONTROL RELAY PS PRESSURE SWITCH CT CURRENT TRANSFORMER PT POTENTIAL TRANSFORMER CV CHECK VALVE PVC POLYVINYL CHLORIDE (CONDUIT) DB DIRECT BURIED RCP REMOTE CONTROL PANEL DEM DEMAND RHP RADIANT HEAT PANEL DF DEMAND FACTOR RIL RED INDICATING LIGHT DI AC DIGITAL INPUT POINT (PLC) DO AC DIGITAL OUTPUT POINT (PLC) RO RUN - OFF RTD RESISTANCE TEMPERATURE DEVICE DWG DRAWING RTM RUN TIME METER E,EXIST EXISTING RTU REMOTE TELEMETRY UNIT EF EXHAUST FAN RV REDUCED VOLTAGE ES EMERGENCY STOP RVAT REDUCED VOLTAGE AUTO F FUSED FACP FIRE ALARM CONTROL PANEL TRANSFORMER STARTER FRP FIBERGLASS REINFORCED PLASTIC S SIGNAL FS FLOW SWITCH SA SURGE ARRESTOR FIT FLOW INDICATING TRANSMITTER SC START COUNTER FVNR FULL VOLTAGE NON -REVERSING SE SERVICE ENTRANCE FVR FULL VOLTAGE REVERSING SHT SHEET G,GND GROUND SS STAINLESS STEEL GEN GENERATOR SSS SOLID STATE STARTER GFI GROUND FAULT INTERRUPTER SV T SOLENOID VALVE THERMOSTAT GIL GREEN INDICATING LIGHT TB TERMINAL BOX GRS GALVANIZED RIGID STEEL CONDUIT (CONDUIT) TC TIME CLOCK H HOT, HIGH, HAND TDOD TIME DELAY ON DE-ENERGIZATION HH HAND HOLE TDOE TIME DELAY ON ENERGIZATION HID HIGH INTENSITY DISCHARGE TDR TIME DELAY RELAY HOA HAND OFF AUTO TEL TELEPHONE HT HEAT DETECTOR TNI TELEPHONE NETWORK INTERFACE HTR HEATER TR TRANSIENT REACTOR IS INTRUSION SWITCH TS TEMPERATURE SWITCH IC ISOLATION CONTRACTOR TSP TWISTED SHIELDED PAIR ISR INTRINSICALLY SAFE RELAY TST TWISTED SHIELDED THREE ISB KAIC INTRINSICALLY SAFE BARRIER THOUSAND AMPS INTERRUPTING CONDUCTOR (TRIAD) TRIAD CURRENT TYP TYPICAL KAWC THOUSAND AMP WITHSTAND CAPACITY UH UNIT HEATER KI KEY INTERLOCK UPS UNINTERRUPTIBLE POWER SUPPLY kVA KILO VOLT AMPS V VAULT kVAR KILO VOLT AMP REACTIVE VB VIBRATION RELAY kVARH KILOVAR HOUR VFD VARIABLE FREQUENCY DRIVE kW KILOWATT WFP WATER FILTRATION PLANT kWH KILOWATT HOUR WFR WATER FILTER PLANT L LOW WHM WATT HOUR METER LC LIGHTING CONTACTOR WIL WHITE INDICATING LIGHT LCP LOCAL CONTROL PANEL WP WEATHER PROOF LE LEVEL ELEMENT XFMR TRANSFORMER LK LEAK XP EXPLOSION PROOF LS LEVEL SWITCH, LIMIT SWITCH ZS POSITION SWITCH LT LEVEL TRANSMITTER LIT LEVEL INDICATING TRANSMITTER LPU LIGHTNING PROTECTION UNIT LTG LIGHTING R-405627 ISSUE FOR CONSTRUCTION CASNEEngineering CE F E B RUARY 08, 2019 3545 FACTORIA BOULEVARD SE., SUITE 200 BELLEVUE, WA 98006 (425) 522-1000 WWW. CA SNE. COM JOB NO. 191- 027 a SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE � L C of WAS�ACCEPTABILITY DRAWN CASNE DATE 08.04.15 SUBTITLE ELECTRICAL LEGEND, ABBREVIATIONS CURRENT REVISION SYMBOL A DATE o2.08.19 - APRON C CI PROJECT W3441886 CASNE CEC 12.14.15 CHECKED RJJ 08.04.15 (�) THIS DESIGN 0 v SPECIFICATION IS APPROVED SHEET o - RECORD DRAWING - 737 MAX FLIGHTLINE UTILITIES W3441886 CASNE DAT 12.19.16 ® _ P OVED BY DEPT. DATE ENGINEER JEA 08.04.15 TITLE APRON C PARCEL 820 EO B E 2 CHECKED A APRON C PARCEL 820 CASNE CEC 02.08.19 35276 w�' CEC 08.04.15 APRON C JOB N0. COMP N0. APPROVED o, W3441886 SS10NAL� I ELECTRICAL MASTER YARD RENTON, WA APPROVED DWG NO. 05-APRON-C-EO-A