GROUP II TOFA (EXISTING)
SYM REVISION BY APPROVED DATE SYM
- APRON C Cl PROJECT W3441886 CASNE CEC 12.14.15
- RECORD DRAWING - 737 MAX FLIGHTLINE UTILITIES W3441886 CASNE DAT 12.19.16
A APRON C PARCEL 820 CASNE CEC 02.08.19
20 10 0 10 20 40
SCALE: 1:20
APRON C PLAN
SCALE: 1 " = 20'
TAXIWAY A
GENERAL NOTES
1. ALL NEW STRUCTURES AND FACILITIES ARE PARALLEL
AND PERPENDICULAR TO EAST BOEING LEASE LINE AT
BEARING N4°48'53"W.
2. PER IFC 2009, CHAPTER 11, AVIATION FACILITIES:
AIRCRAFT BEING FUELED SHALL BE POSITIONED SUCH
THAT ANY FUEL SYSTEM VENTS AND OTHER FUEL TANK
OPENINGS ARE A MINIMUM OF TWENTY-FIVE FEET (7620
MM) FROM BUILDINGS OR STRUCTURE OTHER THAN JET
BRIDGES; AND FIFTY FEET (15,240 MM) FROM AIR
INTAKE VENTS FOR BOILER, HEATER OR INCINERATOR
ROOMS.
3. REPAIR OR REPLACE ANY AND ALL PAVEMENT DISTURBED
DURING CONSTRUCTION IN ACCORDANCE WITH C501 AND
THE SPECIFICATIONS.
4. CONTRACTOR SHALL SUBMIT BORING PLANS AND
PROFILES TO DESIGN TEAM FOR APPROVAL PRIOR TO
MOBILIZING.
5. CONTRACTOR SHALL PROVIDE THOROUGH LOCATE SERVICE
FOR ALL AREA'S IN BORE OR TRENCH PATH.
6. ALL BURIED CONDUIT NOT ENCASED IN CONCRETE SHALL
BE PVC COATED RIGID. EXCEPTION: 400HZ CONDUIT
SHALL BE RIDIG ALUMINUM.
7. ABOVE GRADE EXPOSED CONDUIT SHALL BE EITHER RIGID
ALUMINUM OR PVC COATED RIGID STEAL. PER THE
SPECIFICATIONS LOW VOLTAGE.
8. ALL POWER CONDUCTORS SHALL BE XHHW.
9. ALL CONDUITS ENTERING OR EXITING THE EARTH
SHALL HAVE EXPLOSION PROOF SEALOFFS.
05-APRON-C-E4A
CONSTRUCTION NOTES
THIS DRAWING REFLECTS THE END RESULT OF THE
DEMOLITION PROCESSES OF DRAWING E110R.
O m o0 I- co Ln r7 N O M 00 r- (.0Ln � n N O
M) N N N N N N N N N N
-14
_
APRON
„
��
-
RE
-
TON
MUN
CIPA
AIR
ORT
F-
a�
RU
W
APR
N
G-
IRE
I
o
,4
Z
olak
!!!!f
A:lRON
IV
20/
1
0
a
AQo
_
❑o
_
'0
A
�
81
12
co
0-5DIq,
6
1 -18
M PAR
AV
NUE
N.
-.
i
-
COMPLE
PAR
ING
L01
6
o-405
z
ISSUE FOR CONSTRUCTION
FEBRUARY 08, 2019
REVISION
BY
APPROVED
DATE
1 " — (-"4
�4 of WAs�,I &_ ACCEPTABILITY
THIS DESIGN AND/OR
UNAWN
C. ALLISON
UAi t
07.15.15
SUBTITLE
480Y/277V POWER PLAN - C6 AND C7
CHECKED
®
SPECIFICATION IS APPROVED
ENGINEER
TITLE APRON C PARCEL 820
""A,
,AW"
P OVED BY DEPT. DATE
CHECKED
35276
APRON C
APPROVED
I STERN C1�'
�SSjONAL ��1 I
APPROVED
ELECTRICAL MASTER
KEY PLAN z
SCALE: NONE
rECASNEEngineering
3545 FACTORIA BOULEVARD SE., SUITE 200
BELLEVUE, WA 98006
(425) 522-1000 WWW. CASNE. COM JOB NO. 191- 027
CURRENT REVISION SYMBOL DATE
A 02.08.19
SHEET
E110 E23-
JOB NO. COMP NO.
W3441886
RENTON, WA DWG NO. 05-APRON-C-El10
A
B
C
D
E
F
G
HI
J
K
LI