HomeMy WebLinkAboutR-397406CB #1 (TYPE II-48"0)
~ W/ ROUND SOLID LOCKING LID
O
C'7 STA = 4+95.62, 11.2'f R
RIM = 441.59
It _ - - It (12" LCPE W) = 432.28
I T V-"(T2" PVC-S}-,432.2Z -
0
LLI
PORTION OF THE SW 1/4, SECTION 14, T. 23 N., R. 5 E., W.M. TREE DRIPLINE (TYP)
B TYPE 1
EXISTING TREES
W/ VANED GRATE � � � , _
STA = 5D G.54, 12.0' R \\ i ROPOSED MAILBOX LOCATION LOCATED IN ROW
RIM = 443.69 \ CB #3,1'YPE 1) \/�6�UNIT) PER C.O.R. STD PLAN H026. BE REMOVED (TYI
REMOVE EX. CB 2 & 12 \ W VANED GRATE \SESHEET C16
INV (12" PVC E, S) = 439.20 STORM PIPE IN SE 2ND PL. / \ STA / 7+12.49, 12.0' R \
- - - C.O. FOR VAULT FROM VAULT CONNECTION I 68 / -
TOWARDS 156TH AVE. I O I R14 = 454.50
FOOTING DRAIN (TY�) - - - - - - - r j 0� I IN�/ (12" PVC W) = 450.00
SDCO #5 AQ 185LF 12" PVC
w RIM = 444.00 8 0 _�`
- J- -w / --.- - - I -
/ 24LF 2 PVC
117
_ c0 S=0.00-------------
-� ------ -
JT���T-fN G
IL THIS SH
- - - - - - -----
-
-�--------J I
-------------- L--------- -
Q 22LF 12"I PVC
0 S=0.0100 \
I-- 551'51 "E 110.04'
_09 #10 (TYPE 11-48"0^-)
=
W/ ROUND SOLID LOCKING LID
U)
N=178,194.63, E=1,318,738.31
RIM = 443.00
Lu
INV (12" PVC S) = 433.40
(D
INV (4" PVC SW, SE) = 433.00
0
INV (8" PVC E) = 432.83
I
INV (12" PVC N) = 432.50
I
I
I
d
Q
3LF 12" PVC
0 S=0.033
Lu
INV(12" OUT)=433. C
I
U
-/
37LF 8" PVC
PRIVATE @ S=0 01
I
l0
\
I
BOLLARDS (TYP.)
ppo��
\p�4" PERF. PVC FOOTING
DRAIN SEE DETAIL
SHEET C08 (TYP.)
I
15' WIDE ACCESS ROAD
IMPERVIOUS AREA=1,402 SF 0')
SEE PAVEMI NT DETAIL SHEET C10
Do
SEE SHEET 08
O
W
W
U)
v 1 U+UU I
CURB RAMP -
LOCATION AS PER
6�TAIL ON SHEET 1 1 20+00 10
0 10 20 40
_ GRAOHIC SCALE
I } I 6 448
INV 12" IN)� 437.00110 I~0 I �s 7 . 7 . -..:. _ �� �_
�4R "� I a 2 4ss SCALE: 1 20 1468 I.
I 0 X AC SS 45 a 3:: I `so \ 68
RA (TYP• a.o\ z \ I a PROVIDE CONNECTION POINT I #4 i I I
- - - - - - - - - o z - �D #3 N FOR TRENCH DRAIN. SEE I RIM = 4.67 - L_ 38.6'� I I I
�o w - - - - - - - - - - RIM - 461.33 NOTE THIS SHEET INV (8 PVC - 462.67 A-88.5° i W I
I
LOT 1 1a I \ - - - - - - \ -INV = 459.33 (8 PVC S, E) 29LF 8 PVC 4g R-25 iuj
o
1 1 1a I I LOT 2 I `� I ' ---� ---- 0 s-°.loss-_ s � � W J I,
PAD=452 I I LOT 3 1 \ - - - - - _ -
1 PAD=453 I I / - PROVIDE
I PAD=456 I I I LOT 4 I l a LOT 5 \) 1 ( \ CONNECTION I Z W
PAD=459 I ao I LOT 6 I POINT FOR X. I ~
/ (� \ I I SDCO #1 11 \ PAD=462 1 1 1 I TRENCH DRAIN. I\ i W1 Q
448 - - - -452 - - / \ /� I RIM = 459.97 I i c I SDCO #3D=465 ISEE o I I i
� I I��PVC S) = 457.96 r� 20LF 8 PV I I SHEETOTE THIS iv QO446 450 454�-------/ 0 S=0.4196 RIM = 464.00 I �` z U 10
444 �' 448 452 I 458 / INV (8"�P1�C N, S) �1459.56 - i I �Ar
442 446 456 460 46
- - - - - - - w 450 454 I -
/ INV (12"PVC IN) = 437.00 c\j/ - - - -444 - - - _ N 448 452 I 456 458 46 I W �I i ��
--- 450 �---- 4 4 46 C i o
I 01 I 15 EASEMENT SETBACK (TYP.) (CON FOR ROOF AND \ , - - - - - - - - - - - \ - 45 - - - - 3: 1+ of
/ - ------ 0 I PAD=442 zI I �RI ,F )eTING DRAINS (TYP) ( � / - iR N
FOR DETAILS F -0b I I I PAD=443 I G 34LF 8 PVC
EXPOSED VAULT / 442 25LF 12 PVC 110' PRIVATE STORM I PAD=446 I� I I I I 0 S=0.064,E 19LF 8" PVC \ I N
DETENTION C� S=0.0108 I I I I PAD=449 I 0 S=0.3036
l� VAULT \ - - , bRAINAGE EASEMENT I I SDCO #2 I PAD=452 I I I rn 0
o -- PRlvrr=-------------- - RIM = 451.63 I I I PAD=455 I\ o I 22'-� I I
73LF 12" PVC --- -------------------------/ INS( (8" PVC N, S) = 449.63 � Ln 38LF 8" PVC � I SDCO#4 I �'
- - / (� S=0.0276 t, RIM - 455.64 \
= 70LF 12" PVC -----,------- - - ----------- /
440 = OLF 8 PVC ----------- _ - `�` INV (8_PVC N, S� 453.79 I of
- ----------- -� - _ - 70LF 8" PVC ---- ---------- - - OD
Ln
-� _ _ 70LF 8" PVC -
PORTION OF _ ; , / /NORM DRAIN CB #6 (TYPE 1) / / / - - - - - - - L - - - - - - - ---
- - \ 4 441.3,1 / - - - - - - S=0.0757
VAULT WITH / �8 » / S - 1--- ---- -- - _
EXPOSED WALL I TRACT INV = 2 6 "4T1/C 41 CB #7 (TYPE I) I N ®S��` YD #1 - -
PRIvc I INV = 437.2 2 PV E) I RIM=�441.48 I S 6 RIM = 450 \ -
\ I �� \ 41
INV = 438. 6" P C �O o ---- - --- -- INV = 4�" PVC N, E,
136LF 8" PVC _ _ - \ \ vv �» O� - - - - - ) 25' VEGETAWD
/ - !� \ INV = 438.00 (1 €, W) i I 00 _ 46 4y� - - - FLOW P TH
0 S=0.0100 - - - - - - - - - - - - - 452 \
� I
'43"W 110.03 - - 48.1' / - - �- 438 _ 40 ---- - - - - - - _ j C ���� - - -
DETENTION VAULT (PUBLIC) �� -- \ (� �r - - \ L------_ _
----
-- 70 0 / \ \ / n ------
J87°36'4 ' W 1 04' ------------- \�
87' LONG X 36' WI[Gt A y' uttP - / / / \/ \ \
7' LIVE STORAGE SEDIMENT STORAGE - YD #6 DRAINAGE SWALE SEE POTENTIAL LOCATION FUTURE -��_ 70 p° \ \ \ \ \ \/ / \ /�\ / /� \ \ �� I
/ FZIM - 437.00 DOWNSPOUT OUTFALL TO GRAVEL 70.0'� / \ \ \ r --J
TOP OF VAULT (OUTSIDE) = 442.00 INV = 434.56 (8" PVC N) DETAIL BELOW (TYP) YD #5 871'36' 3" 373, Io o /�/ \ \ \ \ \ 0� c_
TOP OF VAULT (INSIDE) - 441.00 = DISPERSAL TRENCH (TYP.) RIM = 442a5 V 1 1 1 ` 1 1 I 1 I I I I 6LF 12 D.�
INV 434.73 (4 PERF. PVC SE) SEE FUTURE DOWNSPOUT NOTE _ \ I / / I - _ i ® S=0.020
WATER SURFACE ELEVATION = 440.50 ( ) INV 439.75 (6 PVC NW) \ \ \ \ \ I \/ / / y 1 1 1 I I - - - - -�
CB #11 (TYPE 1) \ \ / / / / / / \ �1/ 1 1 / 1 I I v
INV. (12" PVC OUT) = 433.50 W VANED GRATE DRAINAGE SWALE WITH 4" PERF. STORM CB #9 TYPE I \ \ \ \ \ \ / / / YD #2
/ CB #8 (TYPE I) -( ) \ ��� y /�� \� / /\\ /\ \ / / /
(SEE DETAILS, SHEET C07, C08) _ DRAIN PLACED AT BOTTOM OF SWALE - RIM = 447.69 _ \ \ / / RIM'= 454.60
STA - 3+78, 12 R RIM - 444.01 .� i i
RIM - 435.31 = _ INV = 452.74 8 PVC N W
INV 439.20 (6�" SE, N) INV 443.216" PVC N) -� \ y\ \ / (" ) I o
INV - 431.57 (12 LCPE S, E) INV = 439.03 (8 PVC E) INV = 443.21 (8 PVC E, W) 50 VEGETATED FLOW PATH - O
INSTALL NEW CB IN LINE WITH INV = 438.70 (12" PVC W) FOR DOWNSPOUT I ++ I o
FUTURE CURB AND GUTTER LOCATION TREE DRIPLINE (TYP) DISPERSION (TYP) 10' PRIVATE STORM DRAINAGE EASEMENT CB #4 I N W/ VANED GRATE To
Emil,,-rJAL- ..
•.
IIII •'
REMOVE10,
01
-4D
.
00
• : .
1
�iwmmm
w-M �
Mrs
!L� hi i 1111 _ \ - - -•Rm
3+46 4+00 S.E. 2ND P C>� -
�- '�---�-----
5
NOTE:
_ - _ IoS) -
(RESIDENTIAL ACCESS)_-
EACH LOT WILL BE REQUIRED TO DEMONSTRATE COMPLIANCE
WITH THE ONSITE BMP REQUIREMENTS FOUND IN SECTION
I- J I
o i--- ----- ___-________ J
C.1.3.1 OF THE 2017 RENTON SURFACE WATER DESIGN MANUAL
------- --
I
AT THE TIME OF SINGLE FAMILY BUILDING PERMIT REVIEW.
o I
_ --SD - -117LF 12"
A MINIMUM OF 4900SF OF ROOF DRAINAGE IS REQUIRED TO BE
30.01' - J
DISPERSED BY THE FUTURE LOTS ACCORDING TO THE
_
1 �_
REMOVE EX. 12" SD
TECHNICAL INFORMATION REPORT PREPARED BY PACIFIC
\ AND CAP
ENGINEERING DATED 5/8/18
cd I I I
FOG LINE 25:1 TAPER I I
W I I
A PUBLIC STORM DRAINAGE MAINTENANCE EASEMENT WILL
I
12LF\ 12" LCPE I I
OCCUPY THE ENTIRETY OF THE STORM DRAINAGE TRACT.
Z S=0.0057
I
SOIL MOISTURE CAPACITY OF NEW PERVIOUS SURFACES MUST
W I
EX. CB %, I
BY PROTECTED IN ACCORDANCE WITH THE SOIL AMENDMENT
i STA = 3+78.50, 24.3' R / I i
Q
BMP AS DETAILED IN SECTION C.2.13.1 OF THE 2017 RSWDM
I RIM = 434.71
= INV = 431.50 (EX. 12" PVC W) 1 I
I I I
INV = 431.50 (12" LCPE N) \ I I
INDIVIDUAL LOT FOOTING DRAIN SHALL NOT TIE TO
STORM SYSTEM PRIOR TO THE CATCH BASIN FOR THE
\\ I I
RESPECTIVE LOT.
CONTRACTOR TO VE FY RIM AND IN�XERT -
'"' ELEVATIONS PRIOR T� CONSTRUCTION.\ I N
CONNECT NEW SD LINE TO EX. CB
ee�-SONG
OFF -SITE STORM DRAINAGE CONNECTION
SCALE: l'-30'
Pacific Z-rj 1fJ,;tj 1
Desiti-ri, } f _r;
L g
M ,I'iI
�� ' Ci+uiJ a�r�glrle+�rlrf��
Planning Cara .a1 }lri r�'-
v 1v flv
TRENCH DRAIN NOTE:
REVERSE SLOPE DRIVEWAYS ON LOTS 5 AND 6
WILL REQUIRE A TRENCH DRAIN AT THE FACE
OF GARAGE. TRENCH DRAIN DESIGN TO BE
PROVIDED WITH HOUSE DESIGNS.
FUTURE DOWNSPOUT NOTE:
DOWNSPOUT TO SPLASHPAD LOCATIONS SHOWN
ON LOTS 1-6 ARE SCHEMATIC ONLY. INDIVIDUAL
LOT DESIGN TO INCLUDE LOCATION OF OUTFALL
AND 50' VEGETATED PATH INFO (LOTS 1-5),
25' VEGETATED PATH INFO (LOT 6)
RESTRICTED FOOTPRINT NOTE:
THIS PROJECT IS UTILIZING RESTRICTED IMPERVIOUS FOOTPRINTS TO MEET
ON -SITE FLOW -CONTROL BMPS. AS SUCH, THE FOLLOWING MAXIMUM
IMPERVIOUS FOOTPRINTS (HOUSE, DRIVEWAYS, DECKS, PATIOS, WALK) ARE
RESTRICTED TO:
LOT
RESTRICTED TO (SF)
NORM. FOOTPRINT FOR R-4 ZONE (SF)
1-5
3,600
4,000
6
2,996
4,000
3 3RD ROUND REVISIONS PER CITY COMMENTS
2 2ND ROUND REVISIONS PER CITY COMMENTS
1 1ST ROUND REVISIONS PER CITY COMMENTS
NO. REVISION
SURVEYED°
DRYCO
AJL
6 5 18
oEsIGN L° LARSEN
AJL
5/8/18
JF
AJL
3/9/18
JF
DRAWN,
E. MARSHALL
AJL
1 /10/17
JF
CHECKED.
J. FENG
BY
DATE
APPR
APPRO"En,
J. FENG
SCALE
1 "=20'
SWALE CROSS SECTION
ONE INCH
AT FULL SCALE
IF I ONE INCH
SCALE ACCORDINGLY
NOT TO SCALE 'II -III;
4" PERF. PIPE
DRAINAGE SWALE
NOTE:
OFFSETS TO STORM STRUCTURES IN SE
2ND PL & 156TH AVE SE ARE MEASURED
TO FACE OF CURB (OR FUTURE FACE OF
CURB) ALL OTHER OFFSETS ARE
MEASURED TO CENTER OF STRUCTURE.
STA = 21 +68.35, 21' R
RIM = 457.20
INV = 454.89 (12" D.I. E) 1
CB #5 (TYPE II - 48" 0)
W/ SOLID LOCKING LID
STA = 21 +68.33, 14'f L
RIM = 457.83
INV = 454.18 (12" D.I. W)
INV = 454.18f (EX. 12" PVC N, S) I
CONTRACTOR TO FIELD VERIFY INVERT ELEVATIONS
AT EXISTING SYSTEM PRIOR TO CONSTRUCTION. 1 L
EXISTING GRADE NOTIFY ENGINEER OF ANY DISCREPANCIES.
I
4' MIN. EXCAVATED R-397406 Q
SOILS 2 ��\ IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY + DEVELOPMENT ENGINEERING
rstraka 07/23/2018 rnair 07/30/2018 0
0
O
O
T
u
O
O
i
T
a
J
C'7
O
O
mX
V
ERTICAL NAw'988 CITY OF
HORIZONTALPRI -ONNAD 1983/1991
RENTON
DATUM
Planning/Building/Public Works Dept.
OP
DATE,
CEDAR RIDGE SHORT PLAT 8-8-2017 fr
FlELDBOOK.
PAGE
WAN NG NO. a
GRADING AND DRAINAGE PLAN 0
W
SHEET, c
os c22 U