Loading...
HomeMy WebLinkAboutD_Sunset_Park_Phase_2_190710_FINALDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map Sunset Neighborhood Park SR_Sunset_Park_Phase_2 A. ADMINISTRATIVE REPORT & DECISION Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED Report Date: July 10, 2019 Project File Number PR15-000009 Project Name: Sunset Neighborhood Park Phase 2 Owner: City of Renton, Community Services Department Applicant/Contact: Alan Wyatt, Capital Projects Manager, 1055 S. Grady Way, Renton, WA 98057 Land Use File Number: LUA19-000114, SA-A Project Manager: Matt Herrera, Senior Planner Project Summary: The City of Renton's Community Services Department is requesting Administrative Site Plan Review for Phase 2 of the Sunset Neighborhood Park located at 2805 NE 10th Street. The subject property is 3.2 acres, zoned Center Village (CV), and is encircled by Sunset Lane NE and NE 10th Street. The proposed park improvements include grading and construction activities that will accommodate pedestrian plazas with seating, playground and fitness areas, picnic area, interactive water feature, pedestrian pathway system, and open lawn areas. The initial phase of the park has been completed which includes restrooms, seating areas, open lawn, and pedestrian walkways. Phase 2 was initially approved with the previous site plan review application (LUA16-000966) however that application has since expired. No substantive changes from what was initially approved has been proposed and Phase 2 generally follows the previous approval. The Renton Sunset Terrace Redevelopment Master Site Plan (File LUA14-001475) approved in January 2015 anticipated the development of the Sunset Neighborhood Park in its proposed location. Project location is also within the Sunset Area Community EIS Planned Action Ordinance area. Project Location: 2805 NE 10th Street, Renton, WA 98056 (APN 722780-0000) Site Area: 3.2 acres DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 2 of 30 SR_Sunset_Park_Phase_2 Phase 2 B. EXHIBITS: Exhibits 1-5 Environmental Review Committee Memo and Exhibits Exhibit: 6 Administrative Report and Decision Exhibit 7: Phase 2 Site Plan Exhibit 8: Phase 2 Landscape Plan Exhibit 9: Technical Information Report Exhibit 10: Advisory Notes to Applicant C. GENERAL INFORMATION: 1. Owner(s) of Record: City of Renton – Community Services Department 2. Zoning Classification: Center Village (CV) 3. Comprehensive Plan Land Use Designation: Commercial Mixed Use (CMU) 4. Existing Site Use: Sunset Neighborhood Park 5. Critical Areas: None 6. Neighborhood Characteristics: a. North: Multi-family Residential –CV and Residential-14 (R-14) zoning b. East: Public Facility (Library) and retail – CV c. South: Vacant– CV d. West: Vacant– CV 7. Site Area: 3.2 acres D. HISTORICAL/BACKGROUND: Action Land Use File No. Ordinance No. Date Comprehensive Plan N/A 5758 06/22/2015 Zoning N/A 5758 06/22/2015 Annexation – Epstein N/A 1246 04/16/1946 Sunset Area Planned Action EIS LUA10-052 N/A 06/06/2011 Planned Action Ordinance N/A 5740 12/8/2014 Sunset Redevelopment Master Site Plan LUA14-001475 N/A 01/14/2015 Sunset Neighborhood Park LUA16-000966 N/A 02/24/2017 DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 3 of 30 SR_Sunset_Park_Phase_2 Phase 2 E. PUBLIC SERVICES: 1. Existing Utilities a. Water: Water service will be provided by the City of Renton. There is an existing 12-inch water main in Sunset Lane NE. b. Sewer: Sewer service is provided by the City of Renton. There is an existing 12-inch wastewater main located in Sunset Lane NE. There is an existing 12-inch wastewater main located in NE 10th Street. c. Surface/Storm Water: There are two existing bioswale facilities within the northeast corner of the park. Runoff from the site sheet flows to the southwest onto adjacent roadways, and is collected in existing storm drains in Harrington Ave NE and Sunset Lane NE. These then connect into a 24-inch storm drain in NE Sunset Boulevard. 2. Streets: Sunset Lane NE and NE 10th Street loop around the park property. The looped roadway consists of two 10-foot travel lanes with a 6-foot parking lane with pedestrian bulb-outs and 0.5-foot curb on either side of the roadway, and an 8-foot planter and 8-foot sidewalk on the outer portion of the looped road for a total right of way width of 49 feet. 3. Fire Protection: Renton Regional Fire Authority F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts a. Section 4-2-020: Purpose and Intent of Zoning Districts b. Section 4-2-060: Zoning Use Table c. Section 4-2-120: Commercial Development Standards 2. Chapter 3 Environmental Regulations and Overlay Districts a. Section 4-3-100: Urban Design Regulations 3. Chapter 4 City-Wide Property Development Standards 4. Chapter 6 Streets and Utility Standards a. Section 4-6-060: Street Standards 5. Chapter 11 Definitions G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: 1. Land Use Element 2. Parks, Recreation, Natural Areas, and Trails Element H. FINDINGS OF FACT (FOF): 1. The Planning Division of the City of Renton accepted the above master application for review on May 21, 2019 and determined the application complete on May 30, 2019. The project complies with the 120-day review period. 2. The project site is located at 2805 NE 10th Street APN 722780-0000. 3. The project site is currently developed with the initial phase of the Sunset Neighborhood Park. The site contains a restroom, pedestrian areas, open lawn, and bioswale. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 4 of 30 SR_Sunset_Park_Phase_2 Phase 2 4. Access to the site would be provided via pedestrian crosswalks and on-street parking. No onsite vehicle access to the site is proposed. 5. The property is located within the Commercial Mixed Use (CMU) Comprehensive Plan land use designation. 6. The site is located within the Center Village (CV) zoning classification. 7. Trees and shrubs were planted in the intial phase of development of the park. No trees are proposed to be removed. 8. The site is not mapped with any critical area. 9. Approximately 1,683 cubic yards of fill is proposed to be brought into the site. No removal of soils is proposed. 10. The applicant is proposing to begin Phase 2 construction in late summer to early fall 2019 and complete in 2020. 11. The proposed project is referred to as Site M in the Renton Sunset Redevelopment Master Site Plan and Conditional Use Permit approved by the City’s Hearing Examiner on January 14, 2015 12. The Renton Sunset Redevelopment Master Site Plan remains valid and effective through January 14, 2025. 13. The City determined that the Renton Sunset Redevelopment Master Site Plan is within the development levels or parameters as specified in the Sunset Planned Action Ordinance, Ordinance No. 5740 (Exhibit 3). No additional Environmental ‘SEPA’ Review is required for the subject proposal, however on February 20, 2017 the Environmental Review Committee (ERC) issued a concurrence memo that the park proposal is consistant with the Sunset Area Planned Action Ordinance referenced above. Phase 2 as proposed was also reviewed by ERC and the concurrence memo is hereby incorporated into this decision. 14. The intial site plan review approval (LUA16-000966) expired February 24, 2019 and the final phases of the proposal were not completed, therefore the applicant is required to obtain new site plan approval for Phase 2 of the project. No substantive changes are proposed by the applicant and the proposal generally follows the three phased plan as approved in LUA16-000966. 15. Staff received no public or agency comment letters. 16. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. 17. Comprehensive Plan Compliance: The site is designated Commercial Mixed Use (CMU) on the City’s Comprehensive Plan Map. The purpose of the CMU designation is to allow residential uses as part of mixed use developments, and support new office and commercial development that is more intensive than what exists to create a vibrant district and increase employment opportunities. The intention of this designation is to transform strip commercial development into business districts through the intensification of uses and with cohesive site planning, landscaping, signage, circulation, parking, and the provision of public amenity features. The proposal is compliant with the following Comprehensive Plan Goals and Policies if all conditions of approval are met: Compliance Comprehensive Plan Analysis DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 5 of 30 SR_Sunset_Park_Phase_2 Phase 2  Goal L-EE: Build neighborhoods that promote community resiliency through healthy lifestyles, active transportation, proximity to goods and services, access to local fresh food, environmental sustainability, and a feeling of community.  Goal L-FF: Strengthen the visual identity of Renton and its Community Planning Areas and neighborhoods through quality design and development.  Policy L-48: Accommodate change within the Renton community in a way that maintains Renton’s livability and natural beauty.  Policy L-50: Maintain existing, and encourage the creation of additional places and events throughout the community where people can gather and interact. Allow for flexibility in public gathering places to encourage place-making efforts and activities.  Policy L-52: Include human-scale features such as pedestrian pathways, quality landscaping, and public spaces that have discernable edges, entries, and borders to create a distinctive sense if place in the neighborhoods, commercial areas, and centers.  Policy L-57: Complement the built environment with landscaping using native, naturalized, and ornamental plantings that are appropriate for the situation and circumstance and which provide for respite, recreation, and sun/shade.  Policy P-1: Expand parks and recreational opportunities in new and existing locations with an identified need, in order to fill gaps in service and keep pace with future growth. 18. Zoning Development Standard Compliance: The purpose of the Center Village Zone (CV) is to provide an opportunity for concentrated mixed-use residential and commercial redevelopment designed to urban rather than suburban development standards that support transit-oriented development and pedestrian activity. Use allowances promote commercial and retail development opportunities for residents to shop locally. Uses and standards allow complementary, high-density residential development, and discourage garden-style, multi-family development. The proposal is compliant with the following development standards if all conditions of approval are met: Compliance CV Zone Develop Standards and Analysis  Use: Neighborhood Park Staff Comment: Neighborhood parks are a permitted use within the CV zone N/A Density: The density range required in the CV zone is a minimum of 20.0 dwelling units per net acre to a maximum 80 dwelling units per net acre. Assisted living bonus: 1.5 times the maximum density may be allowed subject to conditions of RMC 4-9-065. Net density is calculated after the deduction of sensitive areas, areas intended for public right-of-way, and private access easements from the gross site area. Staff Comment: Not applicable.  Lot Dimensions: The minimum lot size required in the CV zone is 25,000 square feet. There are no minimum lot width or depth requirements. Staff Comment: The subject property is approximately 139,392 square feet and exceeds the minimum lot size requirement.  Setbacks: The minimum front yard setback is 15 feet. The minimum setback may be reduced to 0 ft. through the site plan review process, provided blank walls are not located within the reduced setback. A maximum front yard setback of 20 feet is DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 6 of 30 SR_Sunset_Park_Phase_2 Phase 2 required. The minimum side yard along a street setback is 15 feet. The minimum setback may be reduced to 0 ft. through the site plan review process, provided blank walls are not located within the reduced setback. The maximum side yard along a street setback is 20 feet. There are no minimum side or rear yard setbacks, except 15 feet if the lot abuts or is adjacent to a lot zoned residential. Staff Comment: The proposed neighborhood park does not have a principal building footprint to measure a setback. Additionally, the park is circular and contains no onsite vehicle access to determine front, side, and rear yards. Structures such as the restrooms, pergolas, playground, water feature, picnic gazebo, and seating area are setback a minimum of 15-feet.  Building Standards: The CV zone has a maximum building coverage 65% of total lot area or 75% if parking is provided within the building or within an on-site parking garage. The maximum building height permitted is 50 feet, except 60 feet if the ground floor of the building is in commercial use. Staff Comment: The restroom and picnic gazebo provide a building coverage of 1,840 square feet or 1.3 percent of the total lot area. Maximum proposed heights are limited to approximately 12 feet for the restroom building. Impervious area coverage of the proposed park is further limited by the approved Sunset Terrace Redevelopment Master Plan to 25.6-percent. The proposed improvements meet this limitation as the total proposed impervious areas for the site is 25.56-percent. N/A Building Orientation: See urban design regulations in RMC 4-3-100. Commercial and civic uses shall provide entry features on all sides of a building facing a public right-of- way or parking lot. The front entry of residential only uses shall be oriented to a public or private street developed to the required standards in RMC 4-6-060. Staff Comment: The neighborhood park does not contain a principal building.  Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot landscape strip along all public street frontages. Additional minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4-6-060. Street trees and, at a minimum, groundcover, are to be located in this area when present. Spacing standards shall be as stipulated by the Department of Community and Economic Development, provided there shall be a minimum of one street tree planted per address. Any additional undeveloped right-of- way areas shall be landscaped unless otherwise determined by the Administrator. All parking lots shall have perimeter landscaping as follows: Such landscaping shall be at least ten feet (10') in width as measured from the street right-of-way. Standards for planting shall be as follows: a. Trees shall be two inches (2") in diameter at breast height (dbh) for multi- family, commercial, and industrial uses at an average minimum rate of one tree per thirty (30) lineal feet of street frontage. b. Shrubs at the minimum rate of one per twenty (20) square feet of landscaped area. Up to fifty percent (50%) of shrubs may be deciduous. c. Ground cover in sufficient quantities to provide at least ninety percent (90%) coverage of the landscaped area within three (3) years of installation. Surface parking lots with more than fourteen (14) stalls shall be landscaped as follows: DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 7 of 30 SR_Sunset_Park_Phase_2 Phase 2 Surface parking lots with between 15 and 50 spaces shall provide 15 sf of landscaping per parking space, 51 and 99 spaces shall provide 25 sf of landscaping per parking space, and 100 or more spaces shall provide 35 sf of landscaping per parking space. Perimeter parking lot landscaping shall be at least 10 feet in width, interior parking lot landscaped areas shall have a minimum width of 5 feet. Staff Comment: The park’s programming provides tree, shrub, and groundcover plantings along the pedestrian pathway network between the park and the street as shown in the landscape plan (Exhibit 8). The western portion of the park provides an open lawn area. Street trees will be provided as part of the Sunset Lane NE improvement project.  Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations require the retention of 10 percent of trees in a residential development. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen inches ( 18") caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and Other significant non- native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. Staff Comment: The applicant does not proposed to remove any significant trees. N/A Vehicular Access: A connection shall be provided for site-to-site vehicle access ways, where topographically feasible, to allow a smooth flow of traffic across abutting CA lots without the need to use a street. Access may comprise the aisle between rows of parking stalls, but is not allowed between a building and a public street. Staff Comment: No vehicle access will be provided to the proposed park. Limited access for maintenance vehicles only will be provided. N/A Parking: Residential Uses: Required parking shall be located underground or under building (on the first floor of the structure), or in an attached or detached structure. Any additional parking may not be located between the building and public street unless located within a structured parking garage. Commercial Uses: Parking may not be located between the building and the public street unless located within a structured parking garage. Mixed Use: Joint parking is required subject to RMC 4-4-080E3. Parking regulations do not require a minimum number of parking spaces for park uses. Standard parking stall dimensions are 9 feet by 20 feet, compact stall dimensions are 8 ½ feet by 16 feet. Staff Comment: The neighborhood park is not proposing any general vehicle access onto the property. On-street parking will be provided for the park and other Sunset Terrace Master Site Plan sites with the Sunset Lane NE. The park is intended to be used by DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 8 of 30 SR_Sunset_Park_Phase_2 Phase 2 residents of the Sunset Highlands neighborhood with access provided via walking, bicycling, or other active transportation methods. Through the Sunset Area EIS and Sunset Terrace Master Site Plan processes, the park was limited in impervious coverage and vehicle parking was not envisioned in the development of the park, which result in additional development opportunities in the overall Master Site Plan. Compliant if condition of approval is met Fences and Retaining Walls: A maximum of eight feet (8') anywhere on the lot provided the fence, retaining wall or hedge does not stand in or in front of any required landscaping or pose a traffic vision hazard. There shall be a minimum three-foot (3') landscaped setback at the base of retaining walls abutting public rights-of-way. Staff Comment: A concrete retaining wall rising from grade to approximately 4 feet is proposed to encircle half of the covered picnic area on the southwestern portion of the site. The wall is located approximately 71 feet from the right-of-way with plantings at the base facing Sunset Lane NE. No finish details of the retaining wall were provided. Therefore staff recommends as a condition of approval, the applicant submit final landscape plan that provides detail of textured or patterned concrete for the retaining wall or other finishing method that complements the site development. The revised plans shall be reviewed and approved by the Current Planning Project Manager prior to Civil Construction Permit Approval. 19. Planned Action Ordinance Compliance: The proposed Sunset Neighborhood Park continues to meet the criteria outlined in the Planned Action Ordinance (Ordinance #5610 and #5740) and qualifies as a planned action; the proposal does not require a SEPA threshold determination, preparation of an EIS, or be subject to further review pursuant to SEPA. The applicant will be responsible for complying with all applicable mitigation measures. The Environmental Review Committee has determined the proposal is compliant (Exhibit 1) with the following criteria: Compliance Planned Action Ordinance Compliance  The proposal is located within the Sunset Planned Action area identified in Exhibit 2.  The proposed uses and activities are consistent with those described in the Planned Action EIS and Planned Action Qualifications.  The proposal is within the Planned Action thresholds and other criteria of the Planned Action Qualifications.  The proposal is consistent with the City of Renton Comprehensive Plan and applicable zoning regulations  The proposal’s significant adverse environmental impacts have been identified in the Planned Action EIS.  The proposal’s impacts have been mitigated by application of the measures identified in Attachment B of Ordinance #5610 and #5740, and other applicable DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 9 of 30 SR_Sunset_Park_Phase_2 Phase 2 City regulations, together with any modifications or variances or special permits that may be required.  The proposal complies with all applicable local, state and/or federal laws and regulations, and the Environmental Review Committee determines that these constitute adequate mitigation.  The proposal is not an essential public facility as defined by RCW.36.70A.200(1). 20. Design Standards: The project site is located within Design District ‘D’. The following table contains project elements intended to comply with the standards of the Design District ‘D’ Standards and guidelines, as outlined in RMC 4-3-100.E: Compliance Design District Guideline and Standard Analysis 1. SITE DESIGN AND BUILDING LOCATION: Intent: To ensure that buildings are located in relation to streets and other buildings so that the Vision of the City of Renton can be realized for a high-density urban environment; so that businesses enjoy visibility from public rights-of-way; and to encourage pedestrian activity. a. Building Location and Orientation: Intent: To ensure visibility of businesses and to establish active, lively uses along sidewalks and pedestrian pathways. To organize buildings for pedestrian use and so that natural light is available to other structures and open space. To ensure an appropriate transition between buildings, parking areas, and other land uses; and increase privacy for residential uses. Guidelines: Developments shall enhance the mutual relationship of buildings with each other, as well as with the roads, open space, and pedestrian amenities while working to create a pedestrian oriented environment. Lots shall be configured to encourage variety and so that natural light is available to buildings and open space. The privacy of individuals in residential uses shall be provided for.  Standard: The availability of natural light (both direct and reflected) and direct sun exposure to nearby buildings and open space (except parking areas) shall be considered when siting structures. Staff Comment: Proposed structures within the park are limited in height and size relative to the overall size of the park. Solar exposure would not be effected on or offsite. Most of the park is open space thereby allowing for direct exposure to natural sunlight. N/A Standard: Buildings shall be oriented to the street with clear connections to the sidewalk. Staff Comment: The park has no principal buildings. The restroom structure is oriented to the park for users, as appropriate, however a pedestrian connection leads to the sidewalk. N/A Standard: The front entry of a building shall be oriented to the street or a landscaped pedestrian-only courtyard. Staff Comment: See comment above. N/A Standard: Buildings with residential uses located at the street level shall be: DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 10 of 30 SR_Sunset_Park_Phase_2 Phase 2 a. Set back from the sidewalk a minimum of ten feet (10') and feature substantial landscaping between the sidewalk and the building; or b. Have the ground floor residential uses raised above street level for residents’ privacy. Staff Comment: See comment above. b. Building Entries: Intent: To make building entrances convenient to locate and easy to access, and ensure that building entries further the pedestrian nature of the fronting sidewalk and the urban character of the district. Guidelines: Primary entries shall face the street, serve as a focal point, and allow space for social interaction. All entries shall include features that make them easily identifiable while reflecting the architectural character of the building. The primary entry shall be the most visually prominent entry. Pedestrian access to the building from the sidewalk, parking lots, and/or other areas shall be provided and shall enhance the overall quality of the pedestrian experience on the site. N/A Standard: A primary entrance of each building shall be located on the facade facing a street, shall be prominent, visible from the street, connected by a walkway to the public sidewalk, and include human-scale elements. Staff Comment: The park has no principal buildings. The restroom structure is oriented to the park for users, as appropriate, however a pedestrian connection leads to the sidewalk. N/A Standard: A primary entrance of each building shall be made visibly prominent by incorporating architectural features such as a facade overhang, trellis, large entry doors, and/or ornamental lighting. Staff Comment: See comment above. N/A Standard Building entries from a street shall be clearly marked with canopies, architectural elements, ornamental lighting, or landscaping and include weather protection at least four and one-half feet (4-1/2') wide (illustration below). Buildings that are taller than thirty feet (30') in height shall also ensure that the weather protection is proportional to the distance above ground level. Staff Comment: See comment above. N/A Standard: Building entries from a parking lot shall be subordinate to those related to the street. Staff Comment: See comment above. N/A Standard: Features such as entries, lobbies, and display windows shall be oriented to a street or pedestrian-oriented space; otherwise, screening or decorative features should be incorporated. Staff Comment: See comment above. N/A Standard: Multiple buildings on the same site shall direct views to building entries by providing a continuous network of pedestrian paths and open spaces that incorporate landscaping. Staff Comment: See comment above. N/A Standard: Ground floor residential units that are directly accessible from the street shall include entries from front yards to provide transition space from the street or entries from an open space such as a courtyard or garden that is accessible from the street. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 11 of 30 SR_Sunset_Park_Phase_2 Phase 2 Staff Comment: See comment above. c. Transition to Surrounding Development: Intent: To shape redevelopment projects so that the character and value of Renton’s long-established, existing neighborhoods are preserved. Guidelines: Careful siting and design treatment shall be used to achieve a compatible transition where new buildings differ from surrounding development in terms of building height, bulk and scale.  Standard: At least one of the following design elements shall be used to promote a transition to surrounding uses: 1. Building proportions, including step-backs on upper levels in accordance with the surrounding planned and existing land use forms; or 2. Building articulation to divide a larger architectural element into smaller increments; or 3. Roof lines, roof pitches, and roof shapes designed to reduce apparent bulk and transition with existing development. Additionally, the Administrator may require increased setbacks at the side or rear of a building in order to reduce the bulk and scale of larger buildings and/or so that sunlight reaches adjacent and/or abutting yards. Staff Comment: The park has no principal buildings. The restroom structure is approximately 1,000 square feet and contains a shed-roof line. No transition treatment is warranted as the structure would be the smallest in the immediate area. d. Service Element Location and Design: Intent: To reduce the potential negative impacts of service elements (i.e., waste receptacles, loading docks) by locating service and loading areas away from high-volume pedestrian areas, and screening them from view in high visibility areas. Guidelines: Service elements shall be concentrated and located so that impacts to pedestrians and other abutting uses are minimized. The impacts of service elements shall be mitigated with landscaping and an enclosure with fencing that is made of quality materials.  Standard: Service elements shall be located and designed to minimize the impacts on the pedestrian environment and adjacent uses. Service elements shall be concentrated and located where they are accessible to service vehicles and convenient for tenant use. Staff Comment: The park will contain 32 gallon dome lid garbage receptacles typically associated with neighborhood parks. The receptacles are dispersed throughout the park area where they accessible to park users and Community Services Department staff for maintenance. N/A Standard: In addition to standard enclosure requirements, garbage, recycling collection, and utility areas shall be enclosed on all sides, including the roof and screened around their perimeter by a wall or fence and have self-closing doors. Staff Comment: No refuse and recycling enclosure is proposed or required for neighborhood park uses. N/A Standard: Service enclosures shall be made of masonry, ornamental metal or wood, or some combination of the three (3). Staff Comment: See comment above. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 12 of 30 SR_Sunset_Park_Phase_2 Phase 2 N/A Standard: If the service area is adjacent to a street, pathway, or pedestrian-oriented space, a landscaped planting strip, minimum 3 feet wide, shall be located on 3 sides of such facility. Staff Comment: See comment above. e. Gateways: Intent: To distinguish gateways as primary entrances to districts or to the City, special design features and architectural elements at gateways should be provided. While gateways should be distinctive within the context of the district, they should also be compatible with the district in form and scale. Guidelines: Service elements shall be concentrated and located so that impacts to pedestrians and other abutting uses are minimized. The impacts of service elements shall be mitigated with landscaping and an enclosure with fencing that is made of quality materials. N/A Standard: Developments located at district gateways shall be marked with visually prominent features. Staff Comment: Not applicable. N/A Standard: Gateway elements shall be oriented toward and scaled for both pedestrians and vehicles. Staff Comment: Not applicable. N/A Standard: Visual prominence shall be distinguished by two (2) or more of the following: (a) Public art; (b) Special landscape treatment; (c) Open space/plaza; (d) Landmark building form; (e) Special paving, unique pedestrian scale lighting, or bollards; (f) Prominent architectural features (trellis, arbor, pergola, or gazebo); (g) Neighborhood or district entry identification (commercial signs do not qualify). Staff Comment: Not applicable. 2. PARKING AND VEHICULAR ACCESS: Intent: To provide safe, convenient access to the Urban Center and the Center Village; incorporate various modes of transportation, including public mass transit, in order to reduce traffic volumes and other impacts from vehicles; ensure sufficient parking is provided, while encouraging creativity in reducing the impacts of parking areas; allow an active pedestrian environment by maintaining contiguous street frontages, without parking lot siting along sidewalks and building facades; minimize the visual impact of parking lots; and use access streets and parking to maintain an urban edge to the district. a. Surface Parking: Intent: To maintain active pedestrian environments along streets by placing parking lots primarily in back of buildings. Guidelines: Surface parking shall be located and designed so as to reduce the visual impact of the parking area and associated vehicles. Large areas of surface parking shall also be designed to accommodate future infill development. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 13 of 30 SR_Sunset_Park_Phase_2 Phase 2 N/A Standard: Parking shall be located so that no surface parking is located between: (a) A building and the front property line; and/or (b) A building and the side property line (when on a corner lot). Staff Comment: No onsite vehicle parking is proposed with the neighborhood park. N/A Standard: Parking shall be located so that it is screened from surrounding streets by buildings, landscaping, and/or gateway features as dictated by location. Staff Comment: See comment above. b. Structured Parking Garages: Intent: To promote more efficient use of land needed for vehicle parking; encourage the use of structured parking; physically and visually integrate parking garages with other uses; and reduce the overall impact of parking garages. Guidelines: Parking garages shall not dominate the streetscape; they shall be designed to be complementary with adjacent and abutting buildings. They shall be sited to complement, not subordinate, pedestrian entries. Similar forms, materials, and/or details to the primary building(s) should be used to enhance garages. N/A Standard: Parking structures shall provide space for ground floor commercial uses along street frontages at a minimum of seventy five percent (75%) of the building frontage width. Staff Comment: Not applicable. N/A Standard: The entire facade must feature a pedestrian-oriented facade. The Administrator of the Department of Community and Economic Development may approve parking structures that do not feature a pedestrian orientation in limited circumstances. If allowed, the structure shall be set back at least six feet (6') from the sidewalk and feature substantial landscaping. This landscaping shall include a combination of evergreen and deciduous trees, shrubs, and ground cover. This setback shall be increased to ten feet (10') when abutting a primary arterial and/or minor arterial. Staff Comment: Not applicable. N/A Standard: Public facing facades shall be articulated by arches, lintels, masonry trim, or other architectural elements and/or materials. Staff Comment: Not applicable. N/A Standard: The entry to the parking garage shall be located away from the primary street, to either the side or rear of the building. Staff Comment: Not applicable. N/A Standard: Parking garages at grade shall include screening or be enclosed from view with treatment such as walls, decorative grilles, trellis with landscaping, or a combination of treatments. Staff Comment: Not applicable. N/A Standard: The Administrator of the Department of Community and Economic Development or designee may allow a reduced setback where the applicant can successfully demonstrate that the landscaped area and/or other design treatment meets the intent of these standards and guidelines. Possible treatments to reduce the setback DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 14 of 30 SR_Sunset_Park_Phase_2 Phase 2 include landscaping components plus one or more of the following integrated with the architectural design of the building: (a) Ornamental grillwork (other than vertical bars); (b) Decorative artwork; (c) Display windows; (d) Brick, tile, or stone; (e) Pre-cast decorative panels; (f) Vine-covered trellis; (g) Raised landscaping beds with decorative materials; or (h) Other treatments that meet the intent of this standard... Staff Comment: Not applicable. c. Vehicular Access: Intent: To maintain a contiguous and uninterrupted sidewalk by minimizing, consolidating, and/or eliminating vehicular access off streets. Guidelines: Vehicular access to parking garages and parking lots shall not impede or interrupt pedestrian mobility. The impacts of curb cuts to pedestrian access on sidewalks shall be minimized. N/A Standard: Access to parking lots and garages shall be from alleys, when available. If not available, access shall occur at side streets. Staff Comment: No onsite vehicle parking is proposed.  Standard: The number of driveways and curb cuts shall be minimized, so that pedestrian circulation along the sidewalk is minimally impeded. Staff Comment: One maintenance vehicle only curb cut is provided on the south perimeter of the park. The driveway will limit access via three removable bollards. 3. PEDESTRIAN ENVIRONMENT: Intent: To enhance the urban character of development in the Urban Center and the Center Village by creating pedestrian networks and by providing strong links from streets and drives to building entrances; make the pedestrian environment safer and more convenient, comfortable, and pleasant to walk between businesses, on sidewalks, to and from access points, and through parking lots; and promote the use of multi-modal and public transportation systems in order to reduce other vehicular traffic. a. Pedestrian Circulation: Intent: To create a network of linkages for pedestrians to improve safety and convenience and enhance the pedestrian environment. Guidelines: The pedestrian environment shall be given priority and importance in the design of projects. Sidewalks and/or pathways shall be provided and shall provide safe access to buildings from parking areas. Providing pedestrian connections to abutting properties is an important aspect of connectivity and encourages pedestrian activity and shall be considered. Pathways shall be easily identifiable to pedestrians and drivers. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 15 of 30 SR_Sunset_Park_Phase_2 Phase 2  Standard: A pedestrian circulation system of pathways that are clearly delineated and connect buildings, open space, and parking areas with the sidewalk system and abutting properties shall be provided. (a) Pathways shall be located so that there are clear sight lines, to increase safety. (b) Pathways shall be an all-weather or permeable walking surface, unless the applicant can demonstrate that the proposed surface is appropriate for the anticipated number of users and complementary to the design of the development. Staff Comment: The proposed park contains a pedestrian loop that follows the perimeter of the park with 13 individual spurs that are perpendicular to the loop providing connections to crosswalks on Sunset Lane NE and NE 10th Street. A system of pathways interior to the park’s pedestrian loop provide access to the site’s amenities. The pathways are unobstructed and with pedestrians able to view the entire pathway system as they are walking. The pathways are proposed to be constructed with a combination of permeable concrete and traditional sidewalk type concrete surfaces. N/A Standard: Pathways within parking areas shall be provided and differentiated by material or texture (i.e., raised walkway, stamped concrete, or pavers) from abutting paving materials. Permeable materials are encouraged. The pathways shall be perpendicular to the applicable building facade and no greater than one hundred fifty feet (150') apart. Staff Comment: The park will not have an onsite parking area. N/A Standard: Sidewalks and pathways along the facades of buildings shall be of sufficient width to accommodate anticipated numbers of users. Specifically: (a) Sidewalks and pathways along the facades of mixed use and retail buildings 100 or more feet in width (measured along the facade) shall provide sidewalks at least 12 feet in width. The walkway shall include an 8 foot minimum unobstructed walking surface. (b) Interior pathways shall be provided and shall vary in width to establish a hierarchy. The widths shall be based on the intended number of users; to be no smaller than five feet (5') and no greater than twelve feet (12'). (c) For all other interior pathways, the proposed walkway shall be of sufficient width to accommodate the anticipated number of users. Staff Comment: No principal buildings are proposed within the park; however pathways within the park range in widths between 7 feet and 10 feet, with gathering areas and plaza type spaces of wider widths. N/A Standard: Mid-block connections between buildings shall be provided. Staff Comment: Not applicable b. Pedestrian Amenities: Intent: To create attractive spaces that unify the building and street environments and are inviting and comfortable for pedestrians; and provide publicly accessible areas that function for a variety of year- round activities, under typical seasonal weather conditions. Guidelines: The pedestrian environment shall be given priority and importance in the design of projects. Amenities that encourage pedestrian use and enhance the pedestrian experience shall be included. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 16 of 30 SR_Sunset_Park_Phase_2 Phase 2  Standard: Architectural elements that incorporate plants, particularly at building entrances, in publicly accessible spaces and at facades along streets, shall be provided. Staff Comment: The central plaza area is lined with irrigated planter boxes between each bench.  Standard: Amenities such as outdoor group seating, benches, transit shelters, fountains, and public art shall be provided. (a) Site furniture shall be made of durable, vandal- and weather-resistant materials that do not retain rainwater and can be reasonably maintained over an extended period of time. (b) Site furniture and amenities shall not impede or block pedestrian access to public spaces or building entrances. Staff Comment: The proposed park contains abundant outdoor group seating, benches, playground, fitness area, pergolas, and decorative water feature. Group seating is provided in two designated picnic areas (one covered and one uncovered). Bench seating is provided along the site’s two pergolas in the west and east portion of the park, within the central plaza area, and near the existing rain garden. The playground is located in the southeastern portion of the park adjacent to the uncovered picnic area and adult fitness area. The water feature is preliminary in design, but is anticipated to be a combination of bubblers and emitters with boulders and other natural features. Site furniture is durable as it is composed of steel and composite materials. Materials are coated or specifically designed to allow easy removal of graffiti. Furniture and amenities are located on the perimeter of pedestrian pathways or designated plazas or play areas and do not block pedestrian access through the park. Compliant with intent and guidelines Standard: Pedestrian overhead weather protection in the form of awnings, marquees, canopies, or building overhangs shall be provided. These elements shall be a minimum of four and one-half feet (4-1/2') wide along at least seventy five percent (75%) of the length of the building facade facing the street, a maximum height of fifteen feet (15') above the ground elevation, and no lower than eight feet (8') above ground level. Staff Comment: No principal building is associated with the park and as is typical with park programming, the amenities and open space are open air. However, the park does contain a weather protected picnic area providing an opportunity for cover during inclement weather. 4. RECREATION AREAS AND COMMON OPEN SPACE: Intent: To ensure that areas for both passive and active recreation are available to residents, workers, and visitors and that these areas are of sufficient size for the intended activity and in convenient locations. To create usable and inviting open space that is accessible to the public; and to promote pedestrian activity on streets particularly at street corners. Guidelines: Developments located at street intersections should provide pedestrian-oriented space at the street corner to emphasize pedestrian activity (illustration below). Recreation and common open space areas are integral aspects of quality development that encourage pedestrians and users. These areas shall be provided in an amount that is adequate to be functional and usable; they shall also be landscaped and located so that they are appealing to users and pedestrians N/A Standard: All mixed use residential and attached housing developments of ten (10) or more dwelling units shall provide common opens space and/or recreation areas. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 17 of 30 SR_Sunset_Park_Phase_2 Phase 2 (a) At minimum, fifty (50) square feet per unit shall be provided. (b) The location, layout, and proposed type of common space or recreation area shall be subject to approval by the Administrator. (c) Open space or recreation areas shall be located to provide sun and light exposure to the area and located so that they are aggregated to provide usable area(s) for residents. (d) At least one of the following shall be provided in each open space and/or recreation area (the Administrator may require more than one of the following elements for developments having more than one hundred (100) units): i. Courtyards, plazas, pea patches, or multi-purpose open spaces; ii. Upper level common decks, patios, terraces, or roof gardens. Such spaces above the street level must feature views or amenities that are unique to the site and are provided as an asset to the development; iii. Pedestrian corridors dedicated to passive recreation and separate from the public street system; iv. Recreation facilities including, but not limited to, tennis/sports courts, swimming pools, exercise areas, game rooms, or other similar facilities; or v. Children’s play spaces that are centrally located near a majority of dwelling units and visible from surrounding units. They shall also be located away from hazardous areas such as garbage dumpsters, drainage facilities, and parking areas. (e) The following shall not be counted toward the common open space or recreation area requirement: i. Required landscaping, driveways, parking, or other vehicular use areas. ii. Required yard setback areas. Except for areas that are developed as private or semi-private (from abutting or adjacent properties) courtyards, plazas or passive use areas containing landscaping and fencing sufficient to create a fully usable area accessible to all residents of the development. iii. Private decks, balconies, and private ground floor open space. iv. Other required landscaping and sensitive area buffers without common access links, such as pedestrian trails. Staff Comment: Not applicable.  Standard: All buildings and developments with over thirty thousand (30,000) square feet of nonresidential uses (excludes parking garage floorplate areas) shall provide pedestrian-oriented space. (a) The pedestrian-oriented space shall be provided according to the following formula: 1% of the site area + 1% of the gross building area, at minimum. (b) The pedestrian-oriented space shall include all of the following: i. Visual and pedestrian access (including barrier-free access) to the abutting structures from the public right-of-way or a non-vehicular courtyard; and ii. Paved walking surfaces of either concrete or approved unit paving; and DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 18 of 30 SR_Sunset_Park_Phase_2 Phase 2 iii. On-site or building-mounted lighting providing at least four (4) foot-candles (average) on the ground; and iv. At least three (3) lineal feet of seating area (bench, ledge, etc.) or one individual seat per sixty (60) square feet of plaza area or open space. (c) The following areas shall not count as pedestrian-oriented space: i. The minimum required walkway. However, where walkways are widened or enhanced beyond minimum requirements, the area may count as pedestrian- oriented space if the Administrator determines such space meets the definition of pedestrian-oriented space. ii. Areas that abut landscaped parking lots, chain link fences, blank walls, and/or dumpsters or service areas. (d) Outdoor storage (shopping carts, potting soil bags, firewood, etc.) is prohibited within pedestrian-oriented space. Staff Comment: The entire 3.2 acre park is pedestrian oriented space. Such spaces include paved walking surfaces, numerous group and bench seating area, open grass area, playground and fitness areas, rain garden with interpretive signage, and water feature. N/A Standard: Public plazas shall be provided at intersections identified in the Commercial Arterial Zone Public Plaza Locations Map and as listed below: (a) Benson Area: Benson Drive S./108th Avenue S.E. and S.E. 176th. (b) Bronson Area: Intersections with Bronson Way North at: i. Factory Avenue N./Houser Way S.; ii. Garden Avenue N.; and iii. Park Avenue N. and N. First Street. (c) Cascade Area: Intersection of 116th Avenue S.E. and S.E. 168th Street. (d) Northeast Fourth Area: Intersections with N.E. Fourth at: i. Duvall Avenue N.E.; ii. Monroe Avenue N.E.; and iii. Union Avenue N.E. (e) Grady Area: Intersections with Grady Way at: i. Lind Avenue S.W.; ii. Rainier Avenue S.; iii. Shattuck Avenue S.; and iv. Talbot Road S. (f) Puget Area: Intersection of S. Puget Drive and Benson Road S. (g) Rainier Avenue Area: Intersections with Rainier Avenue S. at: i. Airport Way/Renton Avenue S.; ii. S. Second Street; iii. S. Third Street/S.W. Sunset Boulevard; DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 19 of 30 SR_Sunset_Park_Phase_2 Phase 2 iv. S. Fourth Street; and v. S. Seventh Street. (h) North Renton Area: Intersections with Park Avenue N. at: i. N. Fourth Street; and ii. N. Fifth Street. (i) Northeast Sunset Area: Intersections with N.E. Sunset Boulevard at: i. Duvall Avenue N.E.; and ii. Union Avenue N.E. Staff Comment: Not applicable. N/A Standard: The plaza shall measure no less than one thousand (1,000) square feet with a minimum dimension of twenty feet (20') on one side abutting the sidewalk. Staff Comment: Not applicable. N/A Standard: The public plaza must be landscaped consistent with RMC 4-4-070, including at minimum street trees, decorative paving, pedestrian-scaled lighting, and seating. Staff Comment: Not applicable. 5. BUILDING ARCHITECTURAL DESIGN: Intent: To encourage building design that is unique and urban in character, comfortable on a human scale, and uses appropriate building materials that are suitable for the Pacific Northwest climate. To discourage franchise retail architecture. a. Building Character and Massing: Intent: To ensure that buildings are not bland and visually appear to be at a human scale; and ensure that all sides of a building, that can be seen by the public, are visually interesting. Guidelines: Building facades shall be modulated and/or articulated to reduce the apparent size of buildings, break up long blank walls, add visual interest, and enhance the character of the neighborhood. Articulation, modulation, and their intervals should create a sense of scale important to residential buildings.  Standard: All building facades shall include modulation or articulation at intervals of no more than forty feet (40'). Staff Comment: The bathroom building contains modulation at intervals between 6 and 16 feet along the east elevation and approximately 20-feet along the west elevation. The building is separated by a 16-foot wide breezeway roof structure providing additional articulation.  Standard: Modulations shall be a minimum of two feet (2') deep, sixteen feet (16') in height, and eight feet (8') in width. Staff Comment: Modulations are approximately 4 feet deep with widths between 6 and 16 feet. Modulations span the entire height of the 10-foot high building. N/A Standard: Buildings greater than one hundred sixty feet (160') in length shall provide a variety of modulations and articulations to reduce the apparent bulk and scale of the facade (illustration in District B, below); or provide an additional special feature such as a clock tower, courtyard, fountain, or public gathering area. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 20 of 30 SR_Sunset_Park_Phase_2 Phase 2 Staff Comment: Bathroom building façade is approximately 60 feet in width including the breezeway trellis. b. Ground-Level Details: Intent: To ensure that buildings are visually interesting and reinforce the intended human-scale character of the pedestrian environment; and ensure that all sides of a building within near or distant public view have visual interest. Guidelines: The use of material variations such as colors, brick, shingles, stucco, and horizontal wood siding is encouraged. The primary building entrance should be made visibly prominent by incorporating architectural features such as a facade overhang, trellis, large entry doors, and/or ornamental lighting (illustration below). Detail features should also be used, to include things such as decorative entry paving, street furniture (benches, etc.), and/or public art.  Standard: Human-scaled elements such as a lighting fixture, trellis, or other landscape feature shall be provided along the facade’s ground floor. Staff Comment: The restroom building contains a trellis roof structure connecting the men’s and women’s facility. The height of the trellis is approximately 10 feet and with the maximum of height of the overall building of 12 feet at top of shed-roof, the elements of the trellis and building maintain a human scale. Lighting fixtures are provided on the north and south elevations above the restroom’s entries and within the trellis breezeway between the men’s and women’s restroom. Additional detail features in and around the building include, 2’x2’ score pattern paving, 32-gallon trash receptacle, bicycle racks, and foundation landscaping. Compliant with Intent and Guidelines Standard: On any facade visible to the public, transparent windows and/or doors are required to comprise at least 50 percent of the portion of the ground floor facade that is between 4 feet and 8 feet above ground (as measured on the true elevation). Staff Comment: The proposed park contains only one enclosed building, which is a restroom facility. Therefore transparent windows would be an inappropriate ground-level detail. A clerestory frosted window is provided on the east and west elevations that provide visual interest and natural lighting within the building. Compliant with Intent and Guidelines Standard: Upper portions of building facades shall have clear windows with visibility into and out of the building. However, screening may be applied to provide shade and energy efficiency. The minimum amount of light transmittance for windows shall be 50 percent. Staff Comment: See discussion above. N/A Standard: Display windows shall be designed for frequent change of merchandise, rather than permanent displays. Staff Comment: Not applicable. N/A Standard: Where windows or storefronts occur, they must principally contain clear glazing. Staff Comment: See discussion above  Standard: Tinted and dark glass, highly reflective (mirror-type) glass and film are prohibited. Staff Comment: No tinted or reflective glass is proposed. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 21 of 30 SR_Sunset_Park_Phase_2 Phase 2 N/A Standard: Untreated blank walls visible from public streets, sidewalks, or interior pedestrian pathways are prohibited. A wall (including building facades and retaining walls) is considered a blank wall if: (a) It is a ground floor wall or portion of a ground floor wall over 6 feet in height, has a horizontal length greater than 15 feet, and does not include a window, door, building modulation or other architectural detailing; or (b) Any portion of a ground floor wall has a surface area of 400 square feet or greater and does not include a window, door, building modulation or other architectural detailing. Staff Comment: Not applicable. N/A Standard: If blank walls are required or unavoidable, blank walls shall be treated with one or more of the following: (a) A planting bed at least five feet in width containing trees, shrubs, evergreen ground cover, or vines adjacent to the blank wall; (b) Trellis or other vine supports with evergreen climbing vines; (c) Architectural detailing such as reveals, contrasting materials, or other special detailing that meets the intent of this standard; (d) Artwork, such as bas-relief sculpture, mural, or similar; or (e) Seating area with special paving and seasonal planting. Staff Comment: Not applicable. c. Building Roof Lines: Intent: To ensure that roof forms provide distinctive profiles and interest consistent with an urban project and contribute to the visual continuity of the district. Guidelines: Building roof lines shall be varied and include architectural elements to add visual interest to the building.  Standard: Buildings shall use at least one of the following elements to create varied and interesting roof profiles: (a) Extended parapets; (b) Feature elements projecting above parapets; (c) Projected cornices; (d) Pitched or sloped roofs (e) Buildings containing predominantly residential uses shall have pitched roofs with a minimum slope of one to four (1:4) and shall have dormers or interesting roof forms that break up the massiveness of an uninterrupted sloping roof. Staff Comment: The restroom building roof is a shed-roof style with a trellis breezeway. d. Building Materials: Intent: To ensure high standards of quality and effective maintenance over time; encourage the use of materials that reduce the visual bulk of large buildings; and encourage the use of materials that add visual interest to the neighborhood. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 22 of 30 SR_Sunset_Park_Phase_2 Phase 2 Guidelines: Building materials are an important and integral part of the architectural design of a building that is attractive and of high quality. Material variation shall be used to create visual appeal and eliminate monotony of facades. This shall occur on all facades in a consistent manner. High quality materials shall be used. If materials like concrete or block walls are used they shall be enhanced to create variation and enhance their visual appeal.  Standard: All sides of buildings visible from a street, pathway, parking area, or open space shall be finished on all sides with the same building materials, detailing, and color scheme, or if different, with materials of the same quality. Staff Comment: The restroom building is finished on all sides with panel cladding on exterior walls. Panels are a mix of corten steel and cementitious materials. Colors include two shades of grey and two shades of burnt orange. Color schemes are complimentary to each other and building materials are durable and of the same quality.  Standard: All buildings shall use material variations such as colors, brick or metal banding, patterns or textural changes. Staff Comment: Material variations include the two types of panel cladding and their differing widths. The corten steel panels are wider than the cementitious panels and their textures are varied. Color variations include the shades of grey and burnt orange.  Standard: Materials, individually or in combination, shall have texture, pattern, and be detailed on all visible facades. Staff Comment: Exterior cladding is patterned horizontally. Cementitious panels provide a narrow pattern with offset seams and the corten panels are wider with no seams.  Standard: Materials shall be durable, high quality, and consistent with more traditional urban development, such as brick, integrally colored concrete masonry, pre-finished metal, stone, steel, glass and cast-in-place concrete. Staff Comment: Exterior materials are steel or cementitious, which is a combination of cement and wood. These materials are durable and are typical features on structures in the Pacific Northwest. N/A Standard: If concrete is used, walls shall be enhanced by techniques such as texturing, reveals, and/or coloring with a concrete coating or admixture. Staff Comment: Not applicable. N/A Standard: If concrete block walls are used, they shall be enhanced with integral color, textured blocks and colored mortar, decorative bond pattern and/or shall incorporate other masonry materials. Staff Comment: Not applicable.  Standard: All buildings shall use material variations such as colors, brick or metal banding, patterns, or textural changes. Staff Comment: Material variations include the two types of panel cladding and their differing widths. The corten steel panels are wider than the cementitious panels and their textures are varied. Color variations include the shades of grey and burnt orange. 6. SIGNAGE: In addition to the City’s standard sign regulations, developments within Urban Design Districts C and D are also subject to the additional sign restrictions found in RMC 4-4-100G, urban design sign area regulations. Modifications to the standard requirements found in RMC 4-4-100G are possible for those proposals that can comply with the Design District criteria found in RMC 4-3-100F, DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 23 of 30 SR_Sunset_Park_Phase_2 Phase 2 Modification of Minimum Standards. For proposals unable to meet the modification criteria, a variance is required.  Standard: Signage shall be an integral part of the design approach to the building. Staff Comment: A park sign was reviewed, approved, and installed with the initial phase N/A Standard: In mixed use and multi-use buildings, signage shall be coordinated with the overall building design. Staff Comment: Not applicable.  Standard: Corporate logos and signs shall be sized appropriately for their location. Staff Comment: See comment above.  Standard: Entry signs shall be limited to the name of the larger development. Staff Comment: See comment above.  Standard: Alteration of trademarks notwithstanding, corporate signage should not be garish in color nor overly lit, although creative design, strong accent colors, and interesting surface materials and lighting techniques are encouraged. Staff Comment: See comment above.  Standard: Front-lit, ground-mounted monument signs are the preferred type of freestanding sign. Staff Comment: See comment above. N/A Standard: Blade type signs, proportional to the building facade on which they are mounted, are encouraged on pedestrian-oriented streets. Staff Comment: Not applicable  Standard: All of the following are prohibited: a. Pole signs; b. Roof signs; and c. Back-lit signs with letters or graphics on a plastic sheet (can signs or illuminated cabinet signs). Exceptions: Back-lit logo signs less than ten (10) square feet are permitted as area signs with only the individual letters back-lit (see illustration, subsection G8 of this Section). Staff Comment: See comment above.  Standard: Freestanding ground-related monument signs, with the exception of primary entry signs, shall be limited to five feet (5') above finished grade, including support structure. Staff Comment: The proposed sign is a freestanding monument sign that is approximately 3.5 feet above finished grade.  Standard: Freestanding signs shall include decorative landscaping (ground cover and/or shrubs) to provide seasonal interest in the area surrounding the sign. Alternately, signage may incorporate stone, brick, or other decorative materials as approved by the Director. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 24 of 30 SR_Sunset_Park_Phase_2 Phase 2 Staff Comment: The proposed monument sign is surrounded with shrubs and groundcover plantings. The sign is further articulated with uplight luminaires from the pad, Richlite composite sign face, and corten steel accent fin. 6. LIGHTING: Intent: To ensure safety and security; provide adequate lighting levels in pedestrian areas such as plazas, pedestrian walkways, parking areas, building entries, and other public places; and increase the visual attractiveness of the area at all times of the day and night. Guidelines: Lighting that improves pedestrian safety and also that creates visual interest in the building and site during the evening hours shall be provided.  Standard: Pedestrian-scale lighting shall be provided at primary and secondary building entrances. Examples include sconces on building facades, awnings with down-lighting and decorative street lighting. Staff Comment: The restroom building will contain sconce lighting at the entrances to the men’s and women’s facilities as well as two fixtures located within the breezeway connection. Pergola structures will contain down-lighting at the top of each post.  Standard: Accent lighting shall also be provided on building facades (such as sconces) and/or to illuminate other key elements of the site such as gateways, specimen trees, other significant landscaping, water features, and/or artwork. Staff Comment: In-ground light fixtures are located along the park’s north/south main pedestrian walkway and plaza. The lighting highlights the perimeter of the relatively wide pedestrian pathway and provides accent lighting to the plaza’s seating and planter boxes.  Standard: Downlighting shall be used in all cases to assure safe pedestrian and vehicular movement, unless alternative pedestrian scale lighting has been approved administratively or is specifically listed as exempt from provisions located in RMC 4-4- 075, Lighting, Exterior On-Site (i.e., signage, governmental flags, temporary holiday or decorative lighting, right-of-way-lighting, etc.). Staff Comment: Parks are an identified exemption of exterior onsite lighting requirements set forth in RMC 4-4-075. However, pedestrian lighting will be installed along the park’s ring pathway during the Sunset Lane NE capital improvement project. 21. Site Plan Review Analysis: Pursuant to RMC 4-9-200.B, Site Plan Review is required for development in the CV zoning classification when it is not exempt from Environmental (SEPA) Review. For Master Plan applications compliance with the review criteria for Site Plans are analyzed at a general level of detail to ensure nothing would preclude the development of the Site Plan. Given Site Plan applications are evaluated for compliance with the specific requirements of the RMC 4-9-200.E.3 the following table contains project elements intended to comply with level of detail needed for both the Master and Site Plan requests: Compliance Site Plan Criteria and Analysis  a. Comprehensive Plan Compliance and consistency. Staff Comment: See previous discussion under FOF 17, Comprehensive Plan Analysis. Compliant if Conditions b. Zoning Compliance and Consistency. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 25 of 30 SR_Sunset_Park_Phase_2 Phase 2 of Approval are Met Staff Comment: See discussion under FOF 18, Zoning Development Standard Compliance.  c. Design Regulation Compliance and Consistency. Staff Comment: See discussion under FOF 20, Design District Review.  d. Planned action ordinance and Development agreement Compliance and Consistency. Staff Comment: See discussion under FOF 19 for Planned Action compliance. No Development Agreement is proposed or needed for the application.  e. Master Site Plan Compliance and Consistency. Staff Comment: The subject property is identified as Site M in the approved Renton Sunset Terrace Redevelopment Master Site Plan (LUA14-001475) and highlighted as a defining feature of the site plan. Project analysis indicated the future park would provide both active and passive recreation opportunities for the Master Site Plan. The proposal meets the overall intent of the approved master site plan.  f. Off Site Impacts. Structures: Restricting overscale structures and overconcentration of development on a particular portion of the site. Staff Comment: See FOF 20, Design District Review: Building Character and Massing. Structures are limited in number and scale for the park. The proposed restroom and picnic gazebo have a combined footprint of 1,840 square feet for the 3.2 acre park with maximum heights approximately 12 feet. Pergola structures are spaced out over the east and west sections of the park and limited to approximately 10 feet in height. Circulation: Providing desirable transitions and linkages between uses, streets, walkways and adjacent properties. Staff Comment: A ring or loop pathway surrounds the park and provided linkages at Sunset Lane NE and NE 10th Street crosswalks. Internal to the loop pathway, a system of pedestrian pathways provide connections to the park’s amenities. Pathways are relatively wide ranging from 7 to 10 feet in width with areas of accent lighting, landscaping, and seating. Loading and Storage Areas: Locating, designing and screening storage areas, utilities, rooftop equipment, loading areas, and refuse and recyclables to minimize views from surrounding properties. Staff Comment: The proposed park does not contain principal buildings, vehicle loading, or refuse and recycling areas that are typical of a conventional development. Utilities are provided within the restroom building structure and out of view from surrounding properties. Refuse areas are 32 gallon receptacles typical of other City park properties. Views: Recognizing the public benefit and desirability of maintaining visual accessibility to attractive natural features. Staff Comment: The park provides 360-degree visual accessibility throughout the property for onsite and offsite views. Seating and interpretive signage is provided at the park’s Low Impact Development stormwater feature. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 26 of 30 SR_Sunset_Park_Phase_2 Phase 2 Landscaping: Using landscaping to provide transitions between development and surrounding properties to reduce noise and glare, maintain privacy, and generally enhance the appearance of the project. Staff Comment: See discussion under FOF 18, Zoning Development Standard: Landscaping. The proposed park is landscaped to highlight and enhance amenities such as the Low Impact Development stormwater feature, the playground and fitness areas, picnic areas, plaza, and restroom. Lighting: Designing and/or placing exterior lighting and glazing in order to avoid excessive brightness or glare to adjacent properties and streets. Staff Comment: See Lighting discussion under FOF 20, Design Review: Lighting. Pedestrian pathway lighting, restroom sconces, and pergola downlighting are located interior to the project and no offsite glare is anticipated to affect adjacent properties and streets. Pedestrian lighting along the park’s loop pathway will be installed per the City’s adopted lighting standards.  g. On Site Impacts. Structure Placement: Provisions for privacy and noise reduction by building placement, spacing and orientation. Staff Comment: Not applicable. The proposal is a public park and designed for use by residents of the Sunset neighborhood. Structure Scale: Consideration of the scale of proposed structures in relation to natural characteristics, views and vistas, site amenities, sunlight, prevailing winds, and pedestrian and vehicle needs. Staff Comment: Proposed structures are limited in scale relative to the overall size of the 3.2 acre park. Maximum building height is approximately 12 feet and views or amenities within or outside the park are not affected by the scale of the structures. Natural Features: Protection of the natural landscape by retaining existing vegetation and soils, using topography to reduce undue cutting and filling, and limiting impervious surfaces. Staff Comment: The initial phase of the park development will remain. Landscaping: Use of landscaping to soften the appearance of parking areas, to provide shade and privacy where needed, to define and enhance open spaces, and generally to enhance the appearance of the project. Landscaping also includes the design and protection of planting areas so that they are less susceptible to damage from vehicles or pedestrian movements. Staff Comment: See FOF 18, Zoning Development Standard: Landscaping. No parking areas are provided onsite. Landscaping is providing to enhance and delineate pedestrian pathways throughout the park. Landscaping surrounding the picnic areas and active recreation areas provides an identifiable edge to the specific amenities.  h. Access. Location and Consolidation: Providing access points on side streets or frontage streets rather than directly onto arterial streets and consolidation of ingress and egress points on the site and, when feasible, with adjacent properties. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 27 of 30 SR_Sunset_Park_Phase_2 Phase 2 Staff Comment: No onsite vehicle access is proposed for the park. Pedestrian access points are provided along the Sunset Lane NE and NE 10th Street loop road that surrounds the subject property. No arterial streets are abutting the subject property. Internal Circulation: Promoting safety and efficiency of the internal circulation system, including the location, design and dimensions of vehicular and pedestrian access points, drives, parking, turnarounds, walkways, bikeways, and emergency access ways. Staff Comment: Internal circulation for the park is limited to pedestrian pathways. The park contains a loop pathway along the perimeter of the subject property linking to crosswalks and connections to offsite public sidewalks. A system of pathways internal to the park project is connected to the loop pathway all connected to and eventually converging onto the central plaza area resulting in a “hub and spoke” type of design. Along each internal spoke, pedestrians are led to each of the park’s amenities. Loading and Delivery: Separating loading and delivery areas from parking and pedestrian areas. Staff Comment: While the park is pedestrian only without vehicle parking or access, there is a need for City maintenance crews to access areas of the subject property with vehicles for upkeep of the park and stormwater facility. Removable bollards are proposed on the north and south ends of the park along the wider pedestrian pathways. These access areas are limited in time of use and for City authorized vehicles only. Transit and Bicycles: Providing transit, carpools and bicycle facilities and access. Staff Comment: The proposal includes hooped bicycle racks to be located near the restroom building. Pedestrian access to transit along SR900 is provided via spurs along the perimeter pathway leading to crosswalks and public sidewalks along Harrington Ave NE and NE 10th Street. Pedestrians: Providing safe and attractive pedestrian connections between parking areas, buildings, public sidewalks and adjacent properties. Staff Comment: See FOF 20, Design District Compliance.  i. Open Space: Incorporating open spaces to serve as distinctive project focal points and to provide adequate areas for passive and active recreation by the occupants/users of the site. Staff Comment: As intended by the Renton Sunset Terrace Redevelopment Master Site Plan, the proposed park will provide the existing neighborhood and future developments the opportunities for outdoor recreation and serve as a central hub of social activity and interaction. The park will provide passive recreation amenities such as the large grass area, picnic and seating areas, and rain garden interpretive signage. Active recreation opportunities include a children’s playground, adult fitness area, and the pedestrian circulation system around and through the park. A central plaza area with a decorative water feature, two pergola structures, and radial bench seating with little lending libraries provide distinctive project focal points to the park and encourage interaction between neighbors. The proposed park will be a key place-making feature in the Master Plan area.  j. Views and Public Access: When possible, providing view corridors to shorelines and Mt. Rainier, and incorporating public access to shorelines DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 28 of 30 SR_Sunset_Park_Phase_2 Phase 2 Staff Comment: The proposed structures are limited in height to 12 feet and would not block view corridors to shorelines or Mt. Rainier. The shoreline public access requirement is not applicable to the proposal.  k. Natural Systems: Arranging project elements to protect existing natural systems where applicable. Staff Comment: The park is designed around the site’s existing Low Impact Development stormwater feature in the northeastern portion of the property. The stormwater feature will be a focal point and amenity of the park as an interpretive sign and seating area will provide park users an opportunity to learn about stormwater effects on the City’s drainages and ultimately the Puget Sound.  l. Services and Infrastructure: Making available public services and facilities to accommodate the proposed use: Police and Fire. Staff Comment: Police and Fire Prevention staff indicated that sufficient resources exist to furnish services to the proposed development; if the applicant provides Code required improvements. A Fire Impact Fee would not be required for the proposal. Water and Sewer. Staff Comment: The City’s Sunset Lane NE Roadway and Utilities Improvement Plan has been completed and can provide services to the second phase of the park. Drainage. Staff Comment: A Technical Information Report (Exhibit 9) was submitted with the land use application. Based on the City of Renton’s flow control map, the site falls within the Peak Rate Flow Control Standard area matching Existing Site Conditions and is within the East Lake Washington Drainage Basin. The project is not located within an Aquifer Protection Area (APA). The development is subject to Drainage Review in accordance with the 2017 Renton Surface Water Design Manual. Five out the six core requirements and the six special requirements are discussed in the Technical Information Report. The TIR submitted was prepared in accordance with 2009 King County Surface Water Design Manual with 2010 City of Renton Amendments. A supplement report/memo shall be provided that addresses 2017 RSWDM Core Requirement #3, #8 and #9. The development proposes to provide a landscape management plan to mitigate the pollution generating pervious surfaces added as a result of the development. a. The 2017 RSWDM does not allow a landscape management plan as an alternative to a basic water quality facility. The bio-retention system that is proposed on the south side of the property, however, may be used as a basic water quality facility. Updated hydrology model using Western Washington Hydrology Modeling (WWHM) program shall be provided as part of the Civil Construction Permit Application for the bio- retention facility showing that the facility treats 91% of the total runoff volume for the project. Transportation. Staff Comment: No regular vehicle access to the site is proposed. Park and stormwater facility maintenance limited access will be provided on the south portion of the site. Bollards will be located parallel to the driveway restricting access to City vehicles. The DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 29 of 30 SR_Sunset_Park_Phase_2 Phase 2 proposed park contains a pedestrian loop that follows the perimeter of the park with 13 individual spurs that are perpendicular to the loop providing connections to crosswalks on Sunset Lane NE and NE 10th Street. ADA access ramps shall be installed at the intersection of NE 10th Street and Glennwood Avenue NE and along the southwest side of Sunset Lane NE to match the existing ADA ramps on the adjacent side of the roadway. ADA ramp designs shall be provided on the Civil Construction Plans included as part of the Civil Construction Permit Application.  m. Phasing: The proposal is a component of the approved Sunset Redevelopment Master Site Plan, a phased plan to be developed during January 2015 to January 2025. The second phase of the park is anticipated to be completed in 2020. I. CONCLUSIONS: 1. The subject site is located in the Commercial Mixed Use (CMU) Comprehensive Plan designation and complies with the goals and policies established with this designation, see FOF 17. 2. The subject site is located in the Center Village (CV) zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code and conditions of approval, see FOF 18. 3. The proposed site plan review application meets the criteria outlined in the Sunset Area Planned Action Ordinance, see FOF 19. 4. The proposed site plan review application complies with the Urban Design Regulations for Design District ‘D’ provided the applicant complies with City Code and conditions of approval, see FOF 20. 5. The proposed site plan review application complies with the site plan review regulations provided the application complies with City Code and conditions of approval, see FOF 21. 6. The proposed site plan review application complies and is consistent with the approved Sunset Terrace Redevelopment Master Site Plan, see FOF 21. 7. The proposed site plan review application complies with the street standards as established by City Code, provided the project complies with all advisory notes and conditions of approval contained herein, see FOF 21. 8. There are adequate public services and facilities to accommodate the proposed site plan application, see FOF 21. J. DECISION: The Sunset Neighborhood Park, File No. LUA16-000966, as depicted in Exhibit 7, is approved and is subject to the following conditions: 1. As conditioned by the Sunset Terrace Redevelopment Master Site Plan, the applicant shall mail information to property owners within 300 feet of the project site and provide information regarding timelines, extent of construction, and contact information. Evidence of the mailing shall be provided to the Current Planning Project Manager prior to construction permit approval. 2. The applicant submit final landscape plan that provide detail of textured or patterned concrete for the retaining wall or other finishing method that complements the site development. The revised plans DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C City of Renton Department of Community & Economic Development Administrative Report & Decision SUNSET NEIGHBORHOOD PARK PHASE 2 LUA19-000114, SA-A Report Date July 10, 2019 Page 30 of 30 SR_Sunset_Park_Phase_2 Phase 2 shall be submitted to the Current Planning Project Manager prior to Construction Permit Approval for the particular phase. DATE OF DECISION ON LAND USE ACTION: SIGNATURE: Jennifer Henning, Planning Director Date TRANSMITTED this 10th day of July, 2019 to the Applicant/Contact: Applicant/Contact: Alan Wyatt, Capital Projects Manager, 1055 S. Grady Way, Renton, WA 98057 TRANSMITTED this 10th day of July, 2019 to the following: Chip Vincent, CED Administrator Brianne Bannwarth, Development Engineering Manager Amanda Askren, Property Services Vanessa Dolbee, Current Planning Manager Rick Marshall, Fire Marshal K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION: The administrative land use decision will become final if the decision is not appealed within 14 days of the decision date. APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on July 24, 2019. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680), together with the required fee to the Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057. RMC 4-8-110.B governs appeals to the Hearing Examiner and additional information regarding the appeal process may be obtained from the City Clerk’s Office, (425) 430-6510. EXPIRATION: The Administrative Site Development Plan Review decision will expire two (2) years from the date of decision. A single two (2) year extension may be requested pursuant to RMC 4-9-200. RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing through the Hearing Examiner. All communications are public record and this permits all interested parties to know the contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of this doctrine could result in the invalidation of the appeal by the Court. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C 7/10/2019 | 9:04 AM PDT CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATIVE REPORT & DECISION EXHIBITS Project Name: Sunset Neighborhood Park Phase 2 Project Number: LUA19-000114,SA-A Date of Report July 10, 2019 Staff Contact Matt Herrera Senior Planner Project Contact/Applicant Alan Wyatt, Capital Projects Manager, 1055 S Grady Way, Renton, WA 98057 Project Location 2805 NE 10th St APN 722780-0000 The following exhibits are included with the ERC Report: Exhibits 1-5 Administrative Decision Exhibit 6: Administrative Report and Decision Exhibit 7: Phase 2 Site Plan Exhibit 8: Phase 2 Landscape Plan Exhibit 9: Technical Information Report Exhibit 10: Advisory Notes to Applicant CITYOFANDECONOMICDEVELOPMENTENVIRONMENTALREVIEWCOMMITTEEMEMOAPPLICATIONNUMBER:LUA16-000966,SA-AAPPLICANT:CityofRenton—CommunityServicesDepartmentPROJECTNAME:SunsetNeighborhoodParkDESCRIPTIONOFPROPOSAL:TheapplicantisrequestingAdministrativeSitePlanReviewfortheproposedSunsetNeighborhoodParklocatedat2805NE10thSt.Thesubjectpropertyis3.2acresandlocatedwithintheCenterVillage(CV)zoningdesignation.Theproposedparkimprovementsincludegradingandconstructionactivitiesthatwillaccommodaterestrooms,plazaswithseating,playgroundandfitnessareas,picnicarea,interactivewaterfeature,perimeterwalkingpath,andopenlawnareas.TheCityiscurrentlyconstructingSunsetLaneNEandNE10thStreetimprovementstoprovideaccesstotheproposedpark.TheRentonSunsetTerraceRedevelopmentMasterSitePlan(FileLUA14-001475)approvedinJanuary2015anticipatedthedevelopmentoftheSunsetNeighborhoodParkinitsproposedlocation.TheprojectlocationisalsowithintheSunsetAreaCommunityEISPlannedActionOrdinancearea.LOCATIONOFPROPOSAL:2805NE10thStreet,RentonWA98056.APNs722780-0000LEADAGENCY/RESPONSIBLEENTITY:CityofRentonEnvironmentalReviewCommitteeDepartmentofCommunity&EconomicDevelopmentUpondeterminationbytheCity’sEnvironmentalReviewCommitteethattheproposalmeetsthecriteriaoutlinedinthePlannedActionOrdinance(Ordinance#5610and#5740)andqualifiesasaplannedaction,theproposalshallnotrequireaSEPAthresholddetermination,preparationofanEIS,orbesubjecttofurtherreviewpursuanttoSEPA.TheCity’sEnvironmentalReviewCommitteedesignatestheproposalasa“plannedaction”,pursuanttoRCW43.21C.030,asitmeetsallofthefollowingconditions:V’TheproposalislocatedwithintheSunsetPlannedActionArea.TheproposedusesandactivitiesareconsistentwiththosedescribedinthePlannedActionEISandPlannedActionQualifications.“TheproposaliswithinthePlannedActionthresholdsandothercriteriaofthePlannedActionQualifications.“TheproposalisconsistentwiththeCityofRentonComprehensivePlanandapplicablezoningregulations.“Theproposal’ssignificantadverseenvironmentalimpactshavebeenExhibit 1DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C identifiedinthePlannedActionEIS.“Theproposal’simpactshavebeenmitigatedbyapplicationofthemeasuresidentifiedinAttachmentBofOrdinance#5610&#5740,andotherapplicableCityregulations,togetherwithanymodificationsorvariancesorspecialpermitsthatmayberequired.Theproposalcomplieswithallapplicablelocal,stateand/orfederallawsandregulations,andtheEnvironmentalReviewCommitteedeterminesthattheseconstituteadequatemitigation.“TheproposalisnotanessentialpublicfacilityasdefinedbyRCW.36.70A.200(1).SIGNATURES:)i77Dte£_RIM.Marshall,AdministratorDateFire&EmergencyServices-/7c7€zer,AdministratorDateC.E.Vincent,AdministratorDateCommunityServicesDepartmentDepartmentofCommunity&EconomicDevelopmentExhibitsExhibit1ERCMemoExhibit2SunsetAreaPlannedActionElSExhibit3SunsetAreaPlannedActionOrdinanceExhibit4RentonSunsetTerraceRedevelopmentMasterSitePlanApprovalExhibit5SitePlanSheet2DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C SUNSET AREA COMMUNITY PLANNED ACTION FINAL NEPA/SEPA ENVIRONMENTAL IMPACT STATEMENT • VOLUME 1 • APRIL 2011 Issued by: City of Renton NEPA Responsible Entity and SEPA Lead Agency Prepared in partnership with: Renton Housing AuthorityRenton Housing Authority Entire Document Available Upon Request Exhibit 2 DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C CITY OF RENTON, WASHINGTON ORDINANCE NO. 5740 AN ORDINANCE OF THE CITY OF RENTON, WASHINGTON, ESTABLISHING A PLANNED ACTION FOR THE SUNSET AREA PURSUANT TO THE STATE ENVIRONMENTAL POLICY ACT. THE CITY COUNCIL OF THE CITY OF RENTON, WASHINGTON, DOES ORDAIN AS FOLLOWS: SECTION 1. Findings. The Council finds as follows: A. The City is subject to the requirements of the Growth Management Act, RCW 36.70A ("GMA") and is located within an Urban Growth Area; B. The City has adopted a Comprehensive Plan complying with the GMA, and has amended the Comprehensive Plan to address transportation improvements and capital facilities specific to the Sunset Area; C. The City has adopted a Community Investment Strategy, development regulations, and design guidelines specific to the Sunset Area which will guide growth and revitalization of the area, including the Sunset Terrace public housing project; D. The City has prepared an Environmental Impact Statement (EIS) for the Sunset Area, supplemented by an addendum, that addresses the probable significant environmental impacts associated with the location, type, and amount of development anticipated in the Planned Action area; E.The mitigation measures identified in the Planned Action EIS, and attached to this ordinance as Attachment B, together with adopted City development regulations, will 1 Entire Document Available Upon Request Exhibit 3 DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 1 CAO VARIANCE - 1 BEFORE THE HEARING EXAMINER FOR THE CITY OF RENTON RE: Renton Sunset Terrace Redevelopment Master Site Plan Site Plan, Conditional Use Permit LUA14-00001475, SA-M, CUP ) ) ) ) ) ) ) ) ) FINAL DECISION SUMMARY The City has requested Master Site Plan review and a Conditional Use Permit to modify the Sunset Terrace Redevelopment Area by adding 90 additional residential units, increasing the height limit and lot coverage requirements and reducing setbacks. The City has also requested a change in the vesting timeline. The Master Site Plan Review and Conditional Use Permit are approved with conditions. The 10 year expiration request is granted. TESTIMONY Rocale Timmons, senior planner, described the history of the project and the progress to date. She described the site characteristics and the revisions being requested for this process. Ms. Timmons stated since 2011, there have been some entitlements of land uses. The City and its partners have reevaluated the original Master Site Plan since the 2011 approvals of the Planned Action Ordinance and issuance of the FEIS. The preferred alternative was Alternative 3 from the FEIS. The City and its partners are requesting several changes to the preferred alternative including the addition of 90 more residential units, increased building heights, reduced setbacks, increased lot coverages and reclassification of local streets. In return, the City will be able to expand the proposed public park to 3.2 acres. Entire Document Available Upon Request Exhibit 4 DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C Exhibit 5DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C NE 10TH STREETS U N S E T L A N E N E SUNSET LANE NEHARRINGTONAVENUE NEGLENWOODAVENUE NESUNSET LANE NENE 10TH STREETS U N S E T L A N E N E HARRINGTONAVENUE NEPARKPHASE IIPARK PHASE IPARK PHASE II SUNSET NEIGHBORHOOD PARKOVERALL PLAN WITH PHASES100% SUBMITTAL - FOR PERMIT206.682.3051 phone206.682.3245 fax215 WESTLAKE AVENUE NORTH SEATTLE, WA 98109LEGENDABBREVIATIONSIMPERVIOUS CALCULATIONS139,738 SF TOTAL PARK AREA (3.2 ACRES)AREA(SF) DESCRIPTION104,022TOTAL PERVIOUS AREA35,716 TOTAL IMPERVIOUS AREA (25.56%)* STATEOFWASHI NGTONNO.8.JULIETB.VONG57EXPLICENSEDLANDSCAPEARCH ITECT THIS DRAWING FOR REFERENCE ONLYEXHIBIT 7RECEIVED05/24/2019 mherreraPLANNING DIVISIONDocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C SUNSET LANE NEHARRINGTONAVENUE NESUNSET LANE NESUNSET LANE NEGLENWOODAVENUE NE NE 1 0 T H S T R E E T NE 10TH STREET MATCH LINE - SEE L-17 206.682.3051 phone 206.682.3245 fax 215 WESTLAKE AVENUE NORTH SEATTLE, WA 98109 STATEO F W ASHI N GTONNO .8 .JU L IE T B.VON G 57 E X PLICENSE D LANDSC A P E A R C HITECTSUNSET NEIGHBORHOOD PARK PHASE 2 PLANTING PLAN - NORTH 100% SUBMITTAL - FOR PERMIT EXHIBIT 8RECEIVED 05/24/2019 mherrera PLANNING DIVISION DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C SUNS E T L A N E N E HARRINGTONAVENUE NE MATCH LINE - SEE L-16 206.682.3051 phone 206.682.3245 fax 215 WESTLAKE AVENUE NORTH SEATTLE, WA 98109 STATEO F W ASHI N G TONNO.8 .JU L I E T B.VON G 57 EX PLICENSE D LANDSC A P E A R C HITECTSUNSET NEIGHBORHOOD PARK PHASE 2 PLANTING PLAN - SOUTH 100% SUBMITTAL - FOR PERMIT DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C Final Technical Information Report VESTED TO 2009 KCSWDM Sunset Neighborhood Park Prepared for City of Renton March 29, 2017 1100 112th Ave NE Suite 500 Bellevue, WA 98004 Entire Document Available in Laserfiche Submittals Folder EXHIBIT 9 RECEIVED 05/24/2019 mherrera PLANNING DIVISION DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 LUA19-000114 ADVISORY NOTES TO APPLICANT The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as information only, they are not subject to the appeal process for the land use action. Planning: (Contact: Name, 425-430-6593,mherrera@rentonwa.gov) 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight o’clock (8:00) p.m. No work shall be permitted on Sundays. 3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where no further construction work will occur within ninety (90) days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March 31st of each year. The Development Services Division’s approval of this work is required prior to final inspection and approval of the permit. 4. A National Permit Discharge Elimination System (NPDES) permit is required when more than one acre is being cleared. 5. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be retained. 6. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around the drip lines of all retained trees, or along the perimeter of a stand of retained tre es. Placards shall be placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees. 7. This permit is shall comply with the Bald and Golden Eagle Protection Act. The pe rmitted is responsible for adhering to the U.S. Fish and Wildlife Service National Bald Eagle Management Guidelines (2007) and /or your U.S. Fish and Wildlife Service permit. Development Engineering: (Contact: Brianne Bannwarth, 425-430-7299, bbannwarth@rentonwa.gov) See Attached Development Engineering Memo dated June 19, 2019 EXHIBIT 10 DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: June 19, 2019 TO: Mathew Herrera, Senior Planner FROM: Brianne Bannwarth, Development Engineering Manager SUBJECT: Utility and Transportation Comments for Sunset Neighborhood Park Phase II, 2805 NE 10th Street LUA19-000114 I have reviewed the application for the Error! Reference source not found. Phase II at 2805 NE 10th Street (APN(‘s) 7227800000) and have the following comments: EXISTING CONDITIONS The site is approximately 2.4 acres in size and is irregular in shape. The site is located in the Sunset Community area of Renton and consists of a multi-family residential neighborhood owned by the Renton Housing Authority, which included 13 residential building and their associated driveways, concrete walkways, utilities, and public roadway. Water Water Service is provided by the City of Renton’s water service area in the Highlands 565- hydraulic zone. There is an existing 12-inch City water main located in Sunset Lane NE (see Water plan no. W-3875 and W-3752). Static water pressure is approximately 97 psi at elevation 340 ft. Sunset Neighborhood Park Phase I constructed the existing 2-inch irrigation meter on the east side of the site along Sunset Lane NE and the existing 2-inch domestic meter on the northwest side of the site along NE 10th Street. Sewer Wastewater service is provided by City of Renton. There is an existing 12-inch wastewater main located in Sunset Lane NE (see City plan no. S-3875). There is an existing 12-inch wastewater main located in NE 10th Street (see City plan no. S-3875). Storm There is an existing storm drainage system in Sunset Lane NE and Harrington Ave NE. 3. There are two (2) existing bioswale stormwater facilities located within the northeast corner of the park footprint, installed as part of the Sunset Terrace Regional Stormwater Facility, which are proposed to remain (see City plan no. 3658). Runoff from the site sheet flows to the southwest onto adjacent roadways, and is collected in existing storm drains in Harrington Ave NE and Sunset Lane NE. These then connect into a 24-inch storm drain in NE Sunset Boulevard. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C Error! Reference source not found. Phase II – LUAError! Reference source not found. Page 2 of 4 Streets The proposed development fronts Sunset Lane NE and NE 10th Street which provide a loop around the park property. The looped roadway consists of two 10-foot travel lanes with a 6- foot parking lane with pedestrian bulb-outs and 0.5-foot curb on either side of the roadway, and an 8-foot planter and 8-foot sidewalk on the outer portion of the looped road for a total right of way width of 49 feet. CODE REQUIREMENTS WATER 1. The development is proposing the following: a. Connect the proposed decorative mist feature to the existing 2-inch domestic water meter and 2-inch double check valve assembly (DCVA) service line. The decorative mist feature shall be constructed in accordance with the Department of Health regulations. b. Connect the proposed irrigation system to the existing 2-inch irrigation meter and double check valve assembly (DCVA). SEWER 1. The development currently does not require a connection to the City’s sewer system. SURFACE WATER 1. A geotechnical report, dated July 8, 2016, completed by CH2M Hill, Inc. for the site has been provided. Erosion control measures will need to be in place prior to starting grading activities on the site. The report discusses the soil and groundwater characteristics of the site including infiltration potential and provides recommendations for project design and construction. Geotechnical recommendations presented in the report will need to be addressed within the project plans. 2. A Preliminary Drainage Plan and Technical Information Report (TIR), dated March 29, 2017, was submitted by CH2M Hill, Inc. with the Land Use Application. Based on the City of Renton’s flow control map, the site falls within the Peak Rate Flow Control Standard area matching Existing Site Conditions and is within the East Lake Washington Drainage Basin. The project is not located within an Aquifer Protection Area (APA). The development is subject to Drainage Review in accordance with the 2017 Renton Surface Water Design Manual. Five out the six core requirements and the six special requirements are discussed in the Technical Information Report. a. The TIR submitted was prepared in accordance with 2009 King County Surface Water Design Manual with 2010 City of Renton Amendments. A supplement report/memo shall be provided that addresses 2017 RSWDM Core Requirement #3, #8 and #9. 3. The proposed development reduces the amount of impervious surface area from the historical condition and is therefore exempt from Core Requirement #3: Flow Control. 4. The development proposes to provide a landscape management plan to mitigate the pollution generating pervious surfaces added as a result of the development. a. The 2017 RSWDM does not allow a landscape management plan as an alternative to a basic water quality facility. The bio-retention system that is proposed on the south side of the property, however, may be used as a basic water quality facility. Updated hydrology model using Western Washington Hydrology Modeling (WWHM) program shall be provided as part of the Civil Construction Permit Application for the bio- DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C Error! Reference source not found. Phase II – LUAError! Reference source not found. Page 3 of 4 retention facility showing that the facility treats 91% of the total runoff volume for the project. 5. The development is subject to Core Requirement #8 and is required to provide basic water quality treatment prior to discharge. The development proposes to provide a landscape management plan to mitigate the pollution generating pervious surfaces added as a result of the development. a. The 2017 RSWDM does not allow a landscape management plan as an alternative to a basic water quality facility. The bio-retention system that is proposed on the south side of the property, however, may be used as a basic water quality facility. Updated hydrology model using Western Washington Hydrology Modeling (WWHM) program shall be provided as part of the Civil Construction Permit Application for the bio- retention facility showing that the facility treats 91% of the total runoff volume for the project. 6. The development is subject to 2017 RSWDM Core Requirement #9 Onsite BMPs Section 1.2.9.2.2 Large Lot BMP Requirements. Permeable pavement is proposed for the project. 7. No downstream flooding or erosion issues were identified in the report. 8. The current Surface Water Standard Plans shall be used in all drainage plan submittals. These Standard Plans contain the Surface Water Standard Plan Notes (267.00 and 267.10) and the Erosion and Sediment Control Standard plan Notes (268.00). The current City of Renton Standard Plans are available online on the City of Renton website. 9. A Construction Stormwater General Permit from Department of Ecology will be required since grading and clearing of the site exceeds one acre. A Stormwater Pollution Prevention Plan (SWPPP) is required for this site. TRANSPORTATION 1. No ROW dedication will be required from the development. 2. ADA access ramps shall be installed at all street crossings. Ramps shall be shown at each intersection. Ramps shall be oriented to provide direct pedestrian crossings. a. ADA access ramps shall be installed at the intersection of NE 10th Street and Glennwood Avenue NE and along the southwest side of Sunset Lane NE to match the existing ADA ramps on the adjacent side of the roadway. ADA ramp designs shall be provided on the Civil Construction Plans included as part of the Civil Construction Permit Application. 3. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay Requirements. 4. A traffic impact analysis is required when the estimated vehicular traffic generated from a proposed development exceeds 20 vehicles per hour in either the AM (6:00 – 9:00) or PM (3:00 – 6:00) peak periods. The proposed project does not exceed this threshold and therefore is not required to provide a traffic impact analysis. GENERAL COMMENTS 1. Adequate separation between utilities as well as other features shall be provided in accordance with code requirements. a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C Error! Reference source not found. Phase II – LUAError! Reference source not found. Page 4 of 4 b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 2. All construction utility permits for utility and street improvements will require separate plan submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-to-date plan submittal requirements: http://rentonwa.gov/business/default.aspx?id=42473 3. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on separate sheets. 4. All utility lines (i.e. electrical, phone, and cable services, etc.) serving the proposed development must be underground. The construction of these franchise utilities must be inspected and approved by a City of Renton inspector. 5. Fees quoted in this document reflect the fees applicable in the year 2019 only and will be assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current development fee schedule. DocuSign Envelope ID: 42694F89-85FF-46F9-9DEE-458180ACD69C