Loading...
HomeMy WebLinkAboutW-4047010 LU H' rCh'i ORq� tip, SEAL"11C z 1969 �gSil1NG�� 15' SANITARY SEWER EASEMENT, REC. NO. 9012061035 CHAIN LINK FENCE GATE I I IDO NOT �I ENTER SIGN I \ I I I I —W-t- I kx—X—X I — I I — — — — — — — — — — — — — — — — I � I I I I� �` • I \`'9 \ \ %V�ERTI \ems 24�1 PIPE \i1'O \ L - — — — — — — — — — — I I i P i - - - - - - - - - - - - - - / / \/ - I ----------------------------------------�/ / i F----------------- I I / BIO-SWALE (DESIGN) I,------------------------------------- r \ I SDMH 50' WETLAND BUFFER I \ 24"ADS SD / I (48"DIA) _ J �-L--- \ _12" SD -----------12ADS SD I I I I I I I — �----------- ----------------\ --�ta" Ahc cn �//�T/� ---- ' 4.S r.U.IL;. — INSIDE BUILDING DETECTOR CHECK VALVE ASSEMBLY PER RENTON STD PLAN 360 5 I I N39 LF 6" DI 'I I P.I.V..;. cI W/ BOLLARDS ° I i:a I I 'A ItX 00 1+00 r'a --I---- — — - — ioW — — I I INSTALL POLY PIG STATION I i • • • ' . i I 1 N6 VERT. CROSS (FLxMJ) I I 1-BLIND FLANGE ON TOP W/ 2" TAP AND 2 PLUG I I I 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/ 2" TAP & 2" BLOW —OFF I • i I 1-TEMP. CONC. BLOCK --------------J I. I �— I I I I I r I I. . . . .00 I I I I• I INSTALL TEMPORARY 6" CAP (MJ) AND . •I TEMPORARY 2" BLOW —OFF ASSEMBLY W/ TEMPORARY THRUST BLOCKING I I I I --------------------}--.T J-------- TESTING DETAIL CONNECTION DETAIL SCALE: 1 " = 5" ASxj �Lq� BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST (206) 323-4144 ORN SEATTLE, Washington 1-800-935-0508 98102-3513 FAX# (206) 323-7135 era N39 LF 6" DI A I 2+00 �- - - - - - - WETLAND BOUNDARY I16 P.S.1 I I I I I I I ASPHALT I I I I I I STA. 4+74.6, 0.0' — — — — — — —- I----------- 3+00 I 4+00 - - - - - - - - - - - - - - - - - - - - - - - I I I I I I I I STA. 4+81.3, 0.5' L --------------� .I REMOVE POLY PIG STATION AND INSTALL 2N6" SPOOLS 1N6" SLEEVE r I I I I I I I I I I I I I I I - - - - - - - - - - - - - - - - - - - - i-. - -- .- - j - - - - - - - -- REVISION FINAL DETAIL SURVEYED: JMH DESIGNED: ZJE DRAWN: ZJE CHECKED: TFD BY DATE APPR APPROVED: TFD SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 20 10 0 20 40 SCALE IN FEET 1 "=20' T I I I SDM (SOU LID) -- —I v IN COMPLIANCE WITH CITY OF RENTON STANDARDS [DEVELOPMENT ENGINEERING REGIONAL FIRE AUTHORITY r� ^TolAPPROVED stin Johnson 01/09/2019 cthomas 01/09/2019 WATER UTILITY Abdoul Gafour 01/09/2019 DATE: HORIZONTAL- N D 1993i�991 CITY 0 F WATER PLAN 12/6/18 RENTON PALLET STORAGE FIRE SERVICE EXTENSION FlELD900K: • � 800 SW 27TH STREET PAGE. DRAWING N0: DATUM Planning/Building/Public Works Dept. RENTON, WASHINGTON 98057 W i TROJAN LITHO - UNDEGROUND SHEET: 7 OF: 8 W-404701