HomeMy WebLinkAboutR-4047070
LU
H' rCh'i
ORq� tip,
SEAL z
1969 �q�Fl 1 NG��
15' SANITARY SEWER
EASEMENT, REC. NO.
9012061035
CHAIN LINK
FENCE GATE
— iir
I
I
I
IDO NOT �I
ENTER SIGN I�
I I
I
I
—W_t—
I
kx—X—X I —
I I
1— — — — — — — — — — — — — — — —
I � I I I I��• I \�9 \ \
%V�ERTI \ems
24�1 PIPE \i1'O \
L — — — — — — — — — — — I i \ i
- - - - - - - - - - - - - - /
/ \/ - I
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ---�/ / i
r----------------------------------------
I �
I I / BIO—SWALE (DESIGN)
I,------------------------------------ —
r
\ I SDMH 50' WETLAND BUFFER I \
24"ADS SD / (48"DIA) _ J
----------------- 1\ — —
I I I I I I I I I I
I sDI�H I I I I F.D.C. �,. ..�--------------•
I (48r DIA) 15 P.S.I i I �.S •'`i --
I I I I I I I INSIDE BUILDING DETECTOR CHECK I:
I I VALVE ASSEMBLYM//7/
I I I PER RENTON STD PLAN 360 5
I I � u
1 N39 LF 6" DI
I P.I.V.
�I W/ BOLLARDS
�I I
Q1
I I I
----------------------------------------I--�
00 I 1+00—
—I----- — - — io"w — — -
INSTALL POLY PIG STATION I i • • • ' . i I
1 N6 VERT. CROSS (FLxMJ) I I
1-BLIND FLANGE ON TOP W/ 2"
TAP AND 2 PLUG I I I
1-BLIND FLANGE ON BOTTOM
1-PLUG (MJ) W/ 2" TAP & 2"
BLOW —OFF I • • • . . •i I
1-TEMP. CONC. BLOCK I I . ' ' . ' i I
--------------J�-
I I
I
I
I r
I
I . O .I
f .O I
I I
I• I
INSTALL TEMPORARY 6" CAP (MJ) AND
. •I
TEMPORARY 2" BLOW —OFF ASSEMBLY W/
TEMPORARY THRUST BLOCKING
I I
F I
•I
- - - - - - - - - - - - - - - - - - - - �- -- --- - -- - - --
L----- -J
TESTING DETAIL
CONNECTION DETAIL
SCALE: 1 " = 5"
J.
ASxj �Lq�
BUSH, ROED & HITCHINGS, INC.
LAND SURVEYORS & CIVIL ENGINEERS
2009 MINOR AVE. EAST (206) 323-4144
ORN SEATTLE, Washington 1-800-935-0508
98102-3513 FAX# (206) 323-7135
era
N39 LF 6" DI
A
2+00
■- - - - - - - -
WETLAND BOUNDARY
116 P.S. �
I I I SDM
(SOU
LID)
I I
I I I
I I
ASPHAL- I I I
I I
I I STA. 4+74.6, 0.0'
— — — — — — — — — — - I— — — — — — — — — — — _ _ _
3+00 4+00
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
--- ——— — — — — — —
I I STA. 4+81.3, 0.5' L
--------------�
.I
REMOVE POLY PIG STATION AND INSTALL
2N6" SPOOLS
1N6" SLEEVE r
I I
I I
I I
I I
I
I I
I I
I I
- - - - - - - - - - - - - - - - -- - ---.-.---- - j - - - - - - - --
REVISION
FINAL DETAIL
SURVEYED:
JMH
DESIGNED:
ZJE
DRAWN:
ZJE
CHECKED:
TFD
BY DATE AP P R APPROVED:
TFD
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
20 10 0 20 40
SCALE IN FEET
1 "=20'
-- -I
v
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
[DEVELOPMENT ENGINEERING rLEcthomasOl/09/2019
AL FIRE AUTHORITY r� ^Tol+PPROVED istin Johnson 01/09/2019
WATER UTILITY
Abdoul Gafour 01 /09/2019
DATE:
HORIZONTAL- N D 1983/1991 CITY 0 F WATER PLAN 12/6/18
RENTON PALLET STORAGE FIRE SERVICE EXTENSION FlELDBOOK:
• �
800 SW 27TH STREET PAGE.
DRAWING N0:
DATUM Planning/Building/Public Works Dept. RENTON, WASHINGTON 98057 W l
TROJAN LITHO - UNDEGROUND SHEET: 7 OF. 8
W-404701