HomeMy WebLinkAboutzW-4047Set0
LU
H' rCh'i
ORq� tip,
SEAL"11C z
1969 �gSil1NG��
15' SANITARY SEWER
EASEMENT, REC. NO.
9012061035
CHAIN LINK
FENCE GATE
I I
IDO NOT �I
ENTER SIGN I \
I I
I
I
—W-t-
I
kx—X—X I —
I I
— — — — — — — — — — — — — — — —
I � I I I I� �` • I \`'9 \ \
%V�ERTI \ems
24�1 PIPE \i1'O \
L - — — — — — — — — — — I I i P i
- - - - - - - - - - - - - - /
/ \/ - I
----------------------------------------�/ / i
F-----------------
I I / BIO-SWALE (DESIGN)
I,-------------------------------------
r
\ I SDMH 50' WETLAND BUFFER I \
24"ADS SD / I (48"DIA) _ J
�-L---
\ _12" SD
-----------12ADS SD I I I I I I I — �----------- ----------------\
--�ta" Ahc cn �//�T/� ----
' 4.S r.U.IL;. —
INSIDE BUILDING DETECTOR CHECK
VALVE ASSEMBLY
PER RENTON STD PLAN 360 5
I I N39 LF 6" DI
'I I P.I.V..;.
cI W/ BOLLARDS
° I i:a
I I 'A
ItX
00 1+00 r'a
--I---- — — - — ioW — —
I I
INSTALL POLY PIG STATION I i • • • ' . i I
1 N6 VERT. CROSS (FLxMJ) I I
1-BLIND FLANGE ON TOP W/ 2"
TAP AND 2 PLUG I I I
1-BLIND FLANGE ON BOTTOM
1-PLUG (MJ) W/ 2" TAP & 2"
BLOW —OFF I • i I
1-TEMP. CONC. BLOCK
--------------J I. I �—
I I
I
I
I r
I
I. . . . .00 I
I I
I• I
INSTALL TEMPORARY 6" CAP (MJ) AND
. •I
TEMPORARY 2" BLOW —OFF ASSEMBLY W/
TEMPORARY THRUST BLOCKING
I I
I I
--------------------}--.T J--------
TESTING DETAIL
CONNECTION DETAIL
SCALE: 1 " = 5"
ASxj �Lq�
BUSH, ROED & HITCHINGS, INC.
LAND SURVEYORS & CIVIL ENGINEERS
2009 MINOR AVE. EAST (206) 323-4144
ORN SEATTLE, Washington 1-800-935-0508
98102-3513 FAX# (206) 323-7135
era
N39 LF 6" DI
A
I
2+00
�- - - - - - -
WETLAND BOUNDARY
I16 P.S.1
I I
I I I
I I
ASPHALT I I
I I
I I STA. 4+74.6, 0.0'
— — — — — — —- I-----------
3+00 I 4+00
- - - - - - - - - - - - - - - - - - - - - - -
I I I I I I I I STA. 4+81.3, 0.5' L
--------------�
.I
REMOVE POLY PIG STATION AND INSTALL
2N6" SPOOLS
1N6" SLEEVE r
I I
I I
I I
I I
I
I I
I I
I I
- - - - - - - - - - - - - - - - - - - - i-. - -- .- - j - - - - - - - --
REVISION
FINAL DETAIL
SURVEYED:
JMH
DESIGNED:
ZJE
DRAWN:
ZJE
CHECKED:
TFD
BY DATE APPR APPROVED:
TFD
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
20 10 0 20 40
SCALE IN FEET
1 "=20'
T
I I I SDM
(SOU
LID)
-- —I
v
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
[DEVELOPMENT ENGINEERING REGIONAL FIRE AUTHORITY r� ^TolAPPROVED
stin Johnson 01/09/2019 cthomas 01/09/2019
WATER UTILITY
Abdoul Gafour 01/09/2019
DATE:
HORIZONTAL- N D 1993i�991 CITY 0 F WATER PLAN 12/6/18
RENTON PALLET STORAGE FIRE SERVICE EXTENSION FlELD900K:
• �
800 SW 27TH STREET PAGE.
DRAWING N0:
DATUM Planning/Building/Public Works Dept. RENTON, WASHINGTON 98057 W i
TROJAN LITHO - UNDEGROUND SHEET: 7 OF: 8
W-404701