Loading...
HomeMy WebLinkAboutP_Apron E_ floor plan_190627_v1.pdf1 1 A A 2 2 B B 3 3 4 4 5 5 1694 SF ELECTRICAL ROOM 11A1 767 SF COMPRESSOR ROOM 11A2 1522 SF BOILER ROOM 11A3 1294 SF INDUSTRIAL WASTE TANK ROOM 11A4 159' - 8" 50' - 10"23' - 8"46' - 4"38' - 10" 534 J 32' - 8"3 A60 4 A60 1 A60 2 A60 1 A110 1 A110 2 A110 2 A110 1' - 2"1' - 2" 19' - 0" 10' - 0"10' - 0"9' - 10"1' - 2"1' - 2"35' - 0"3 1 1 1 443 5 1 1 1 3 3 6 6 6 6 2 5 3 1 22 3 1 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT.DATE DRAWN DATE CHECKED ENGINEER CHECKED APPROVED APPROVED SUBTITLE TITLE CURRENT REVISION SYMBOL DATE SHEET JOB NO. DWG NO. COMP NO. DESIGN BY:DATE:6/26/2019 3:55:52 PMORIG APRON E - UTILITY BUILDING C199389 RAI EC 06.07.19 Author 06.21.19 Checker 06.21.19 Designer 06.21.19 FLOOR PLAN UTILITY BUILDING RENTON, WA BUILDING 05-71 1-A/5-B 35989 ORIG 06.21.19 1A10 A33 05-71-1A10 Author:ARCHITECTURAL MASTER RAI 06.21.19 LAND USE PERMIT/SEPA NOT FOR CONSTRUCTION 0 4' 8'16' 24' 1/8" = 1'-0" X LEGEND GENERAL NOTES CONSTRUCTION NOTES xxxxxxxxxxxxxx CONSTRUCT EXTERIOR WALL. 6"X18 GA. STEEL STUDS @ 16" O.C., 1/2" PLYWOOD SHEATING, 3" CENTRIA 'FORMAWALL' INSULATED METAL PANEL (EXTERIOR), 5/8" GWB (INTERIOR), 6" CONCRETE CURB BASE. 1 PARTITION TYPE (SEE SHEETS A360 AND A361) DOOR NUMBER (SEE SCHEDULES A350-A355) WINDOW NUMBER (SEE ELEVATIONS SHEET A350) LOUVER NUMBER (SEE SHEET A352) STOREFRONT NUMBER (SEE SHEET A350) RAILING TYPE (SEE SHEET A513) EMERGENCY EYE WASH & SHOWER ELECTRIC WATER COOLER 2A 100 W1 R1 L1 SF1 EWS EWC BUCKLING RESTRAINED BRACE (H = HIGH, L = LOW) (SEE STRUCT.)BRB GUARD POSTGP COMMUNICATION ENCLOSURESCE CARD READERCR CONTROL JOINTCJ PIPE BOLLARDPB NSCALE: 1/8" = 1'-0" FLOOR PLAN CONSTRUCT INTERIOR FRAME WALL. 6"X18 GA. STEEL STUDS @ 16" O.C., 5/8" GWB EACH SIDE, 6" CONCRETE CURB BASE. 2 PROVIDE AND INSTALL 3'-0" X 7'-0" HM DOOR AND FRAME PREP AND PAINT.3 PROVIDE AND INSTALL 6'-0" X 7'-0" HM DOOR AND FRAME PREP AND PAINT.4 PROVIDE AND INSTALL 8'-0" W X 12'-0" H INSULATED SECTIONAL OVERHEAD DOOR, MANUALLY OPERATED. 5 CONCRETE FLOOR SLAB PER STRUCTURAL PREP AND SEAL SLAB.6 LEVEL 1 0' - 0" 12345 ROOF LEVEL 16' - 0" 2 A110 2 A110 1 3 2 4 36 6 6 2 19' - 0"10' - 0"12' - 0"18' - 1 1/2"LEVEL 1 0' - 0" A B ROOF LEVEL 16' - 0" LEVEL 1 0' - 0" 1 A110 1 A110 1 4 18' - 1 1/2"12' - 0"10' - 0" 9' - 10" LEVEL 1 0' - 0" 1 2 3 4 5 ROOF LEVEL 16' - 0" LEVEL 1 0' - 0" 2 A110 2 A110 7 7 7 7 5 5 5 5 2 2 1 16' - 0"2' - 6"16' - 0"5' - 4"12' - 0"5' - 4"20' - 0"4' - 0"10' - 0"LEVEL 1 0' - 0" AB ROOF LEVEL 16' - 0" LEVEL 1 0' - 0" 1 A110 1 A110 1 18' - 1 1/2"ERIC CRANSTON 6604 STATE OF WASHINGTON REGISTERED ARCHITECT SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT.DATE DRAWN DATE CHECKED ENGINEER CHECKED APPROVED APPROVED SUBTITLE TITLE CURRENT REVISION SYMBOL DATE SHEET JOB NO. DWG NO. COMP NO. DESIGN BY:DATE:6/26/2019 3:55:56 PMORIG APRON E - UTILITY BUILDING C199389 RAI EC 06.07.19 Author 06.21.19 Checker 06.21.19 Designer 06.21.19 BUILDING ELEVATIONS UTILITY BUILDING RENTON, WA BUILDING 5-71 35989 ORIG 06.21.19 A60 A35 5-71-A60 Author:ARCHITECTURAL MASTER RAI 06.21.19 LAND USE PERMIT/SEPA NOT FOR CONSTRUCTION 0 8'16' 32' 48' 1/16" = 1'-0" X LEGEND GENERAL NOTES CONSTRUCTION NOTES xxxxxxxxxxxxxx SCALE: 1/8" = 1'-0"A60 1NORTH ELEVATION SCALE: 1/8" = 1'-0"A60 2WEST ELEVATION SCALE: 1/8" = 1'-0"A60 3SOUTH ELEVATION SCALE: 1/8" = 1'-0"A60 4EAST ELEVATION CONSTRUCT EXTERIOR WALL. 6"X18 GA. STEEL STUDS @ 16" O.C., 1/2" PLYWOOD SHEATING, 3" CENTRIA 'FORMAWALL' INSULATED METAL PANEL (EXTERIOR), 5/8" GWB (INTERIOR), 6" CONCRETE CURB BASE. 1 PROVIDE AND INSTALL 3'-0" X 7'-0" HM DOOR AND FRAME PREP AND PAINT.2 PROVIDE AND INSTALL 6'-0" X 7'-0" HM DOOR AND FRAME PREP AND PAINT.3 PROVIDE AND INSTALL 8'-0" W X 12'-0" H INSULATED SECTIONAL OVERHEAD DOOR, MANUALLY OPERATED. 4 TRANSLUCENT PANEL. KALWALL 2 3/4" THICK, CRYSTAL/CRYSTAL.5 LOUVER PER MECHANICAL.6 FAN PER MECHANICAL.7 LEVEL 1 0' - 0" 1 2 3 4 5 ROOF LEVEL 16' - 0" LEVEL 1 0' - 0" 2 A110 2 A110 LEVEL 1 0' - 0" A B ROOF LEVEL 16' - 0" LEVEL 1 0' - 0" J T/FTG -1' - 0" 1 A110 1 A110 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT.DATE DRAWN DATE CHECKED ENGINEER CHECKED APPROVED APPROVED SUBTITLE TITLE CURRENT REVISION SYMBOL DATE SHEET JOB NO. DWG NO. COMP NO. DESIGN BY:DATE:6/26/2019 3:56:01 PMORIG APRON E - UTILITY BUILDING C199389 RAI EC 06.07.19 Author 06.21.19 Checker 06.21.19 Designer 06.21.19 BUILDING SECTIONS UTILITY BUILDING RENTON, WA BUILDING 5-71 35989 ORIG 06.21.19 A110 A36 5-71-A110 Author:ARCHITECTURAL MASTER RAI 06.21.19 LAND USE PERMIT/SEPA NOT FOR CONSTRUCTION 0 8'16' 32' 48' 1/16" = 1'-0" X LEGEND GENERAL NOTES CONSTRUCTION NOTES xxxxxxxxxxxxxx xxxxxxxxxxxxxxX SCALE: 1/8" = 1'-0"A110 1 EAST - WEST BUILDING SECTION LOOKING NORTH SCALE: 1/8" = 1'-0"A110 2 NORTH - SOUTH BUILDING SECTION LOOKING WEST