HomeMy WebLinkAboutS-399904Sanitary Sewer Notes and Specifications
1. All work and work material shall be in conformance with the standards and specifications
of the City of Renton Planning/Building/Public Works [icpartment and the latest edition
of the WSDOT/APWA Standards and Specifications, as ()pproved and modified by the
City of Renton in the Renton Standard Plans & Specifications. A set of approved plans
shall be kept on site at all times during construction.
2. The hours of work in the street right of way shall be per City specifications on weekdays
unless otherwise approved in writing by the Planning/Building/Public Works Department.
An approved traffic control plan must be obtained prior to beginning any work within
public right of way.
3. All locations of existing utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to ovoid damage or
disturbance.
4. A pre -construction conference and a 24 hour notice shall be required prior to starting
new construction. It shall be the contractor's responsibility to secure all necessary
permits prior to starting construction. (inspection will be accomplished by a
representative of the City of Renton.) It shall be the contractor's responsibility to notify
the Public Works inspector 24 hours in advance of backfilling ail Construction-
Contractoris solely responsible for the means, methods and sequences of construction
and for the safety of workers and others on the construction site.
6. It shall be the responsibility of the contractor to attain street use and any other related
permits prior to any construction.
7. Plans approved by the City of Renton, Public Works Department shall take precedence
over all other plans.
B. A copy of these approved plans must be on the job site whenever construction is in
progress.
9- The contractor shall provide the City of Renton with on as --built drawing of the sanitary
sewer system, which has been stamped and Signed by a licensed professional engineer
or licensed professional surveyor.
10, Backfiil shall be placed equally on both sides of the pipe in layers with a loose average
depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95
percent of maximum density. These compacted layers must extend for one pipe
diameter on each side of the pipe or to the side of the trench. Materials to complete the
fill over pipe shall be the some as described.
11. Open cut road crossings for utility trenches on existing traveled roadway shall be
bockfilled with crushed rock, and mechanically compacted unless otherwise approved by
Utility Specifications
12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department. Reference benchmark and
elevations are noted on the plans.
13. Ail disturbed areas shall be seeded and mulched or otherwise stabilized to the
satisfaction of the Department for the prevention of on --site erosion after the completion
of construction.
14. All pipe and appurtenances shall be laid on a properly prepared foundation in
accordance with the standards and specifications of the City of Renton
Planning/Building/Public Works Department and the latest edition of the WSDOT/APWA
Standards and Specifications, as approved and modified by the City of Renton in the
Renton Standard Plans & Specifications. This shall include necessary leveling of the I
trench bottom or the top of the foundation material, as well as placement and
compaction of required bedding material, to uniform grade so that the entire length of
the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be
pea gravel 6 inches above and below the pipe.
15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034,
SDR 35, or ductile iron class 50, unless otherwise approved by the Wastewater Utility.
16. In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches
above finished grade or must have minimum 2' diameter concrete ring poured at grade.
In paved area, cover must slope in all directions to match paving.
12
7' MiN.
T f
NOT TO SCALE
SECTION 14, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
CITY OF RENTON, STATE OF WASHINGTON
MANtIOLE i RAME AN:
SEE STD. PL-AN 401
AD.1lJSIMENT RINGS 12" MIN.)
SEE NOTE 6
MORTAR JOtNT(S) (3/6" MIN.)
SEE NOTE S
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-44.5
STEPS - POLYPROPYLENE STEPS
SHALL RE INCLIJDED
CONCRETE RISER BY PIPE INC.,
OR APPROW 0 r QUAL.
LADDER-PCI.YPROPYI FNF
SiIALL BE ATIACHLO TO 1AANH0L1
MAX_ PIPE Si,C - .F
COIN(R* TL SHELF
PRECAST BASE SECTION
OR CAST IN SHELF
r
A,
I B,
C. D,
.E.�
48" Mai
48"
6" MIN.
5"MIN 24" MIN.
21" I.D.
54" MH
54_-
8" A6;N
5.5" MIN _.. 24" MIN.
24" I.D.
MIN.
6" MIN.1 42" LflN.
.50" I.D.
fU015-
1. STEPS TO BF POLYIPR0I'YLENE SAFETY STOPS,
2, STEPS ARE TO BE IN H ACE BEFORE MANHOLE SEC110NS ARE INSI'AI-LED.
3. CASTING SHALL BE P(i' STD. PLAN Af)1-
4. MANI,OLF SECTIONS To FIF OF REINFORCED PRECAST CONCRF..TF-
5. ALL JOINTS BETWEEN 11,E CONE, RISER RINGS. BRICKS AN1D, CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE (TASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, HP!CKS AND MORTAR ONLY. 641O,KS SHALL BE STACGFRFD To CREATE A ROMN1NG
BOND OR 1/2 BCND. IHE USE OF SHIMS IS PROMI8!fED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) MATH A HIGH SOLIDS URETHANE COATING, wASSFR VC- AROSHIELD OR
APPROVLD EQUAL. COLOR Of' COATING SHALL BE w iiTE.
B. RUBBER GASKETED JOINTS SHALL BF 1N CONFORMANCE WITH ASTM C-443,
9 CHANNEL HEIGHT SHALL BE A MINIMUM OF .5/4 OF THE INSIDE DIAMETER OE THE LARGEST PPE.
113. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
11 IN UN'MPROSFD AREAS. MANHOLES SHALI EXTEND A MINIMUM OF 6" AND A MAXiMUM OF 12"
ABOVE FiNISPED GRADE CR MUST HAVE A MiNIM17M 2' DIAMETER CONCRETE RINGS P(?LIRED AT GLADE,
IN PA'XD AREAS, COVFP. MUST LOPC •N As L. DIRECTIONS -0 MATi;H PAViNC.
t
PUBLIC WORKS
DEPARTMENT
PIe'
STANDARD SANITARY MANHOLE
PATCHED AREA
u
SEAL WITH AR 4000 OR APPROVED
EQUAL AND ORY SAND AFTER PLAN
PATCHING N TS
SM. PLAN - 4001
SEP'rF;MBFR 20, :
OUTSIDE DIAMETER OF
(SEE NOTE 9) ADJUSTMENT RING AND X SEE NOTE 2
X I
BOTTOM OF FRAME
MORTAR JOINT(S) (3/8" MIN.-2" MAX.)
`- ADJUSTMENT RING (I" MIN.). SEE
SEE NOTE 3 AND SPECIAL PROVISION
NOTE 6.
7-OS 3(111.
SECTION
A -A
NOTES
1. REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE
5. CONSTRUCTION AND ADJUSTMENT SWILL BE PERFORMED
WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS ONE
ONLY BY A JOURNEYMAN MASON.
FOOT (k".), ADJUST CASTING FRAME TO PAVEMENT
SURFACE USING RISER RINGS AND MORTAR
6. ADJUSTMENT OF THE FRAME TO GRADE SHALL BE
ACCOMPLISHED WiTH ADJUSTMENT RINGS AND MORTAR ONLY.
2- REPLACE EXCAVATED MATERIAL WITH A MINIMUM OF 9" OF
THE USE OF SHMS iS PROfMBRED-
HMA CLASS }" PG 64-22 (OR TO A DEPTH THAT IS r BELOW
THE 8Cr TOM OF THE UPPER ADJUSTMENT RING V"CfEVER
7. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
IS GREATER) OR AS APPROVED BY THE ENGINEER.
TAPPING UNTIL FRAME 13 FLUSH WrTH PAVEMENT AS
DETERMtWD WITH A STRA#Off EDGE OF SUFFICIENT LENGTH.
3- ADJUSTMENT RW3$ AND FRAME SHALL BE FULLY BEDDED IN
MORTAR. MORTAR SHALL BE ASTM C270 FOR TYPE S.
8. ALL MORTAR "W S SHALL BE TRIMMED FLUSH AND REMAIN
VISIBLE UPON COMPLETION.4.
MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURERS DIRECTIONS.
9. X- T-T MIN. TO Z•6' MAX. - PER ENGINEER'S INSTRUCTION
STD. PLAN - 106
TYPICAL CONSTRUCTION
RoVEO:
PUBLIC WORKS
DEPARTMENT
AND ADJUSTMENT OF
U, r,�
1�1
MANHOL
E RISERS
auo d DA
"ffTOUMA ENGINEERS AND
LAND SURVEYORS,PLLC
255 SW 41st STREET N RENTON, WA 98057
PHONE (425) 251-0665 FAX (425) 251-0625
NO.
REVISION
VARIES' 4.5' MIN.
^- SAWCUT AFTER BACKFILL
DEPTH OF EXISTING PAVEMENT
2" - 6" HMA
EDGE OF PAVEMENT, EDGE
(SEE NOTE 2) 1' 1' OF CURB & GUTTER, OR
MIN. MIN. CENTER or LANE MARKING
Z2- LIMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE
(CSTC) (9-03.9(3)) PER WSDOT STANDARD
2" SAWCUT AND REMOVE SPECIFCATiONS, COMPACTED TO 95%
OR PLANE, SEAL WITH MODIFIED PROCTOR
AR-4000W
CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL
(9-0.3.19). GRAVEL BORROW (9-0.3.14(1)) PER
---- WSDOT STANDARD SPECIFICATIONS OR NATIVE
MATERIAL IF APPROVED IN WRITING BY ENGINEER
BASED ON GEOT'-CH REPORT, COMPACTED TO
WIDTH of TRENCHAS REQUIRED BY SIZE OF 95% MODIFIED PROCTOR.
PROPOSED IMPROVEMENT (SEE WSDOT
STANDARD SPECtFICAT10N 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS
ALLOWANCE FOR ANY SHORING SHORING, IF REQUIRED BY THE WSDOT STANDARD SPECIFICATIONS
NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT:
WSDOT STANDARD SPECIFICATION 7-08.3(1)B * FOR STORM AND WATER PIPE, PER STD PLAN 220,0
* FOR SANITARY SEWER, PER STD PLAN 405
TRENCH WIDTH * FOR JOINT UTILITY TRENCH, SAND WITH 95%
PASSING A #4 SIEVE AND LESS THAN 5% PASSING
A #200 SIEVE
NOTES:
1 WHEN FXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BP.OKE14 OR DETERIORATED
TO A PAVEMENT CONDITION INDEX RATING OF 70 OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND
FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE OEPTH
USED IN THE EXISTING STREET OR THE DEPTH PER C11Y STANDARD, WHICHEVER IS GREATER.
2 PRINCIPAL/ MINOR/COLLE'CTOR, ARTERIAL, & INDUSTRIAL. ACCESS STREETS - MATERIAL AND THICKNESS
SHALL BE HMA Ct. �" PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6".
RESIDENTIAL ACCESS STREETS -- HMA CL 4" PG 64-27. THE THICKNESS SHALL BE THAT OF THE.- EXISTING
PAVEMENT' SECTION AND iN NO CASE LESS THAN 4'.
3. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR
SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB &
GUTTER SHALL BE REMOVED AND REPLACED, OR THE `,BOULDER SHALL BE PLANED OR REMOVED AND
OVERLAID WITH HMA.
4. IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, )HEN THE SIDEWALK AND/OR CURB SHALL BE
REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT-
5. IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP. THE DRIVEWAY OR SIDEWALK RAMP SHALL
BE REPLACED TO MEET ADA STANDARDS.
TYPICAL LONGITUDINAL PATCH SM. PLO - 110.1
PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR I')'R. ', l',11
DEPARTMENT RIGID PAVEMENT WITH OVERLAYAlk
:r
SPECIAL NOT
IN THE EVENT TRANSVERSE PATCHES EXIST
WITHIN THE AFFECTED STREET, THE LENGTH
OF THE PATCH SHALL BE EXTENDED TO
INCLUDE ANY EXISTING PATCH WITHIN 10
FEET OF THE EDGE OF THE PATCH REOUIRED
FOR THE NEW CROSSING AND ANY
SUBSEQUFNT PATCH EDGE WITHIN 10 FEET
Of THE EDGE OF THE SECOND PATCH AND
50 ON UP TO A TOTAL OF 300 FEET
1' t' VARIES 1 1'
MIN MIN MIN MIN
i
I
1RAFfIC FLOW / I
2- HMA -
2" TO B" HM
2' SAWCUL AND REMOVE -
OR PLANE. SEAL. WITH
AR - 4000 W
(EACH SIDE)
2- HMA
SAWCUT AFTER BACKFILL
(EACH :IOE)
I
A {�
i fit
1.--- 6.5' MIN.
2" DEPTH OF
PLANING OR SAWCUT AND REMOVE
VARIES. 6.5' MIN.
1 I V VARIES { 1 1
MIN MIN I I MIN MLN
WIDTH OF TRENCH AS REQUIRED BY SIZE Of PROPOSED
IMPROVEMENT (SEE WSDOT STANOARD SPECIFICATION 2-U9 4)
PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF
NEEDED, SHALL MEET THE REQUIREMENTS OF WSDOT
STANDARD SPECIFICATION"-08 3(1)8
TRENCH WID IN
FACE OF GUTTER OR
EDGE OF PAVEMENT
CENTER LINE DR
LANE LINE
DEPTH OF EXISTING PAVEMENT
\ __
2" - 6" MIN. HMA (SEE NOTE 2)
6" CRUSHED SURFACING TOP COURSE (CSTC)
(9-039(3)) PER WSDOT STANDARD
SPECIFICATIONS. COMPACTED TO 95% MODIFIED
PROCTOR-
CSTC. BANK RUN GRAVEL FOR TRENCH BACKFILL
(9-03.19), GRAVEL BORROW (9-03.14(t)) PER
WSDOT STANDARD SPECIFICATIONS OR NATIVE
MATERIAL IF APPROVED IN WRITING BY ENGINEER
BASED ON GEOTECH REPORT, COMPACTED TO 95%
MODIFIED PROCTOR.
PIPE ZONE BEDDING. MATERIAL- SEE STANDARD
PLAN 110.1.
FOR NOTES, SFE STANDARD PLAN 110,1
0 TYPICAL. TRANSVERSE PATCH FOR STD. PLAN - 110
PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID I'1t F.17
DEPARTMENT I" J10
PAVEMENT VV TM OVERLAY
)'AS -BUILT" NOTE:
"AS --BUILT" IS BASED ON A ACTUAL FIELD SURVEY
BY TOUMA ENGINEERS AND INFORMATION SUPPLIED
BY CONTRACTOR.
TOUMA 1 20' ffl Z01ITAL' W 19W/11f9T I Y CITY OF
TOUMA RENTON
CHECkW-
HT f AT F„LLL SCALEPlanning/Building/Public Works Dept.
F NOT ONE P CN
BY DATE APPR Ammo- I SMI AG"" Y
S-399904
APPROVED FOR CONSTRUCTION
SUBJECT TO ERRORS AND OMISSIONS
156th AVE SE SEWER EXTENSION
SEWER NOTES
PERMIT NUMBER C 18000328