HomeMy WebLinkAboutRC 20190718000524 Instrument Number: 20190718000524 Document:COV Rec: �108.50 Page-1 of 8
Record Date:7/18/2019 12:50 PM
Electronically Recorded King County, WA
Return Address:
City Clerk's Office
City of Renton
�055 S Grady Way
Renton,WA 98057
DECLARATION OF COVENANT
FOR INSPECTION AND MAINTENANrE OF DRAINAGE FACILITIES AND
ON-SITE BMPS
Grantor: Quadrant Corporation
Grantee: City of Renton, a Washin�ton municipal corporation
Legal Description: Lot 17 of Lakeview Crest Subdivision
Records of King County, Washington, Recording No.
Assessor's Tax Parcel ID#: 4144800170
IN CONSIDERATION of the appl'oved Clty of Renton (checkoneofthefo/lowing)
❑✓ Residential Building Permit �Commercial Building Permit
❑Clearing and Grading Permit ❑Civil Construction or Utility Permit
for Permit(s) B18006356 (construction/auildiny/utilityPermit#)relating to the real property
("Property") described above, the Grantor(s), the owner(s) in fee of that Property, hereby
covenants (covenant)with the City of Renton ("City of Renton" or"City"), a municipal corporation
of the state of Washington,that he/she(they)will observe,consent to,and abide by the conditions
and obligations set forth and described in Paragraphs 1 through 9 below with regard to the
Property, and hereby grants (grant) an easement as described in Paragraphs 2 and 3. Grantor(s)
hereby grants(grant), covenants(covenant), and agrees (agree) as follows:
1. The Grantor(s)or his/her(their)successors in interest and assigns("Owners")shall at their own
cost,operate, maintain, and keep in good repair,the Property's drainage facilities constructed
as required in the approved construction plans and specifications R-3934 (project
Plan#) on file with the City of Renton and submitted to the City of Renton for the review and
approval of permit(s) U16006676 (Construction/Building/UtilityPermit#J.The
Property's drainage facilities are shown and/or listed on Exhibit A—Site Plan. The Property's
drainage facilities shall be maintained in compliance with the operation and maintenance
schedule included and attached herein as Exhibit B—Operations and Maintenance. Qrainage
facilities include pipes, channels, flow control facilities, water quality facilities, on-site best
management practices (BMPs) and other engineered structures designed to manage and/or
Page 1 of $
Instrument Number: 20190718000524 Document:COV Rec: $108.50 Page-2 of 8
Record Date:7/18/2019 12:50 PM King County, WA
treat stormwater on the Property. On-site BMPs include dispersion and infiltration devices,
bioretention, permeable pavements, rainwater harvesting systems, tree retention credit,
reduced impervious surface footprint,vegetated roofs and other measures designed to mimic
pre-developed hydrology and minimize stormwater runoff on the Property.
2. Ciiy oT Renion shall have ihe righi io ingress and egress over ihose poriions or ihe Properiy
necessary to perform inspections of the stormwater facilities and BMPs and conduct
maintenance activitiet specified in this Declaration of Covenant and in accordance with the
�enton Municipal Code. City of�enton shall provide at least thirty(30) days' written notice to
the Owners that entry on the Property i�planned for the inspection of drainage facilities.After
the thirty(30) days,the Owners shall allow the City of P.enton to enter for the sole purpose of
inspecting drainage facilities. In lieu of intpection by the City,the Owners may elect to engage
a licensed civil engineer registered in the state of Wathington who has expertise in drainage to
inspect the drainage facilities and provide a written report describing their condition. If the
engineer option is chosen,the Owners shall provide written notice to the City of�enton within
fiif�een (i5)days of receivin,g the City's notice o�'inspection.Within thirty(30)days of giving this
notice,the Owners,or engineer on behalf of the Owners,shall provide the engineer's report to
the City of Renton. If the report is not provided in a timely manner as specified above,the City
of Renton may inspect the drainage facilities without further notice.
3. If City of Renton determines from its inspection, or from an engineer's report provided in
accordance with Paragraph 2,that maintenance, repair, restoration, and/or mitigation work is
required to be done to any of the drainage facilities, City of Renton shall notify the Owners of
the specific maintenance, repair, restoration, and/or mitigation work ("Work") required
pursuant to the Renton Municipal Code. The City shall also set a reasonable deadline for the
Owners to complete the Work, or to provide an engineer's report that verifies completion of
the Work. After the deadline has passed, the Owners shall allow the City access to re-inspect
the drainage facilities unless an engineer's report has been provided verifying completion of
the Work. If the Work is not completed within the time frame set by the City, the City may
initiate an enforcement action and/or perform the Work and hereby is given access to the
Property for such purposes. Written notice will be sent to the Owners stating the City's
intention to perform such Work.This Work will not commence until at least seven(7)days after
such notice is mailed. If, within the sole discretion of the City, there exists an imminent or
present danger, the seven (7) day notice period will be waived and Work will begin
immediately.
4. The Owners shall assume all responsibility for the cost of any Work,or any measures taken by
the City to address conditions as described in Paragraph 3. Such responsibility shall include
reimbursement to the City within thirty(30)days of the receipt of the invoice for any such Work
performed. Overdue payments will require payment of interest at the maximum legal rate
allowed by RCW 19.52.020(currently twelve percent (12%)). If the City initiates legal action to
enforce this agreement, the prevailing party in such action is entitled to recover reasonable
litigation costs and attorney's fees.
5. The Owners are required to obtain written approval from City of Renton prior to filling, piping,
cutting, or removing vegetation (except in routine landscape maintenance) in open vegetated
stormwater facilities (such as swales, channels, ditches, ponds, etc.), or performing any
alterations or modifications to the drainage facilities referenced in this Declaration of Covenant.
Page 2 of $
Instrument Number: 20190718000524 Document:COV Rec: $108.50 Page-3 of 8
Record Date:7/18/2019 12:50 PM King County, WA
fi. Any no�ice or cons�nt required tcr be gi�en or otherwise pravid�d for by the provisions of ti�is
Agreement shal! be effective upon personal deli�ery, r�r three �3�days after ma�ling by Certif�ed
Mail, return reeeipt requested.
7. With re�ard to the rr7atters addressed he�ein, this agreem�nt constitutes tne�ntire agreement
between the parties, and supersedes �II prior discussiot�s, n�gotiations, and all agrePments
whatso��r+�r whether ora�or writte�.
8. This Qeclar�tion of Covenant is intended ta protect the Value and desirability and promc�te
efficient and effiective management vf surfac� wat�r drainage of the real property descri�aed
ab�Ve, and shall inure to th� benefit o�ali the citizens �f the City af R�n��n and €ts successars
and assigns. This Declaration of Co�enant shall run with th� Eand and be binding upon
Grar�tor(s), and Grantar's�s') successors in interest, anc� assigns.
9. `fhis Declaration of Co�enant may be terminated by �xe�ution of a written �greement by the
�wners and the City that is recorded �y King Caunty in its real praperty records.
iN W1�fNE55 WHEREDF, this Declaration of �avenant for t�e lnspection and Maintenance af
Drainage �a�ilities is exeeuted this��`�day of ��-�"�,__�� �� , 20 �
�.�.......,.
� �
GRANTOR, owner of the Property GRAIVTC7R, owner of the Prop�rty
S�ATE OF WA5HINGT�IU }
COU�VTY OF KINC� )s5,
an �his day personally appear�d before me:
����'�-��-°t� _��:"°� ��-� to m� known to f�e the individual�s�
descri�ecf in and who executed t�te within and foregaing instrument and ac�n�wledged that they
signed the sarr►e as tt�eir free and�ofuntary act and deed, for the uses and purposes therein stated.
Given under my hand and offieial seal this '`���� d�y of _�'_�'��,�,��t��� � 2� ��`'� ,
a�� X
t� , �'�
���,��.���,\\q\90141��� - � a�s..,�'" �. ����^ �.
� - �=------
: ��, ' � ���,p
� �.�r,1tl\kt55y�l� �,v " ,ry
„� ���-�'��a�t4�'�����,^ ��� �g� ��—._ �~�,. . .t`'�C.,;.t�# �:°:.��.��
_ ,� ,� o, �'
=�°'�,;�v���. �'r � Frinted name
;� �� � �� � Notary Public in and fc�r the State of
�� ��:�,a ������ � ,� Washington, residir�g at
� �PA � ,m` � �
��►r�� �p+��9 t�q►'�*,��'°°°''�a��� `y,-. � T�:,.�.-(,�...--•�.:°f..�
�
����J��� tl�'�.�''������ My appointmer�t expires �"� d "�.." p. ��
��t�tiw�.°� �. .��m_.�
Page 3 of s
Instrument Number: 20190718000524 Document:COV Rec: $108.50 Page-4 of 8
Record Date:7/18/2019 12:50 PM King County, WA
EXHIBIT A - ON-SITE BMP SITE PLAN
TOTAL LOT/SITE AREA: 8955 SF PERMIT #: B18006356
ADDRESS: 3939 Park Ave N PARCEL NUMBER:
NEW/REPLACED IMPERV. AREA: 3626 SF MAX. IMPERV. SURFACE ALLOWED: 4925 SF
ON-SITE BMP S USED: D ell for limited filtration, erforated i e connection
N 1°51'41"E 85.78' , 8 ,
— RD RD O RD RD RD
100' f:.� r�� c�, c�, Footing drain ' �A °
`-y-' c^' �� +� `'`��see std plan � �,� ��
:
� , 2s3.4 10 Side Setbac� � � I I
�l__ ` � `�.
P..__._ _ .� � I �r7'f' _.
_.___
o A a g `�F _ __ _____.___ ___ ..__---—._._.._.
I d � � — ��� 286 SF Patio Below �, �``�, A � _
� =� - p
__ � � I;�� ��� i�Covered Deck Uncovere� \ � � � o
T i g h t l i n e t .� i D e c k 1 2 S F� � � �
� �j;i i�60 SF � _ �
p I �� L.._..__._._ . ._.=__ ...-__. ., cx>
�,, � � c�� I�
_. Footing s _.�—� il � ��' `� N
, o �
Drain (typ.) o� ; 52' X 58'-6" i� ,.� `� � � � � __ �
d� ; 2,119 SF i� � �= � �'
� � � � ROOF=2732 SF i� o � �� �� -I z o
- �� � �i � i�� �� � �
, � cn v
�C)>.,, � v d 1,i ` - — __Downspout-(ty�.) - i; ,r.,� � �s, — _...._ z
, �
p.. � 9 I .,...._, �� c�cn �..,� - ___ �
r ��a� � ---- - -- � -- O
�'��r-�.�� � � f;i Covered �—�� �� ��
_
_
i`c�,��a � �� � li �,,, ---�orch i -� _�.... _ ��,. �
'�'�S, c� v� s �i �____ --- 10�--S ��. y
�� -- -� � Si t Fen
� c�.. o� u� ' w...w. � __ -- � -- � v�i
� � B - � - 9 ..,,.,,
�',�,. ~`o I `�9 I ``� w
.�
� _
__.
.... �m_.., � � _.__
`�,� � � - $uddFng -- � - --- 1' x 1' '` o ___.
T � a �
rf'� � I
�- — Envelope i c`�tcn asin
� � �� �,
, � 2x10' Trench 6"
"\ �'..._......._.._—_—._—_—...—_. � Per rat d
�$, ___.._ Ex.
� o � _ �.�. ' - I I;�-PiP��Se W411
�__. . ..�_�__._ _.._ _.1_5�_2. 1 __.2»_ `. . _—���_---� Att che De
Concrete Drive ay i � — ��� s,�o��
74] $F c.i �2� Footing drain�, �jP� Drywell �
� see std plan ' � 6� d�pth � �
Storm � � � 10' ESMT 2s3.4 ' ; �ee )� ,�o,-
RD p - - - — - - -_ ..�.
�_ RD RD D RD //�
RD
__,.
Footin drain �
""�� IE=1 1.0
9
»0 16' ,, o
__. bypass �' O �
, 5• a
__ . __ . — _ _ �2
__.
\� _ _ .. N 1°51, 1 E 60.48' � _ —_ �_ � ~`�,\_
,,.� � � � �
�„ , � �v � a
�� �
,� �_, ..__.__�
._-----_.—�._._._._..._.z�------ -_______..—._-----
.. ..�_� _----_"--�'
— Z CL �f Park Ave N
r".
� � ���
' ��� Lot Size 8955 SF Lot Size 8955 SF
"�� t-,�
5 15 `�' Footprint 2119 SF Roof Overhang 2732 SF
Porch/Deck 388 SF Paved Areas 894 SF
0 10 20 40 Total Coverage 2507 SF Total Impervious 3626 SF
LAKEVIEW CREST - LOT 17 �ot Coverage 28 % Impervious 40.5 �
SECTION/TOW NSHIP/RANGE:32-24N-5E
� �� � � �.�
��� APPROVED BY: SCALE: 1" = 20'
c zrw�t �
. �� r �, � �� ���
.k.�e� � ��� � � �� ��, � 6��4� TITLE: DATE:
,��� ,�,,,.����,� ��,,��,��„�„ �^��u��,
Instrument Number: 20190718000524 Document:COV Rec: $108.50 Page-5 of 8
Record Date:7/18/2019 12:50 PM King County, WA
EXHIBIT B
Maintenance Details
DRYWELLS FOR LIMITED INFILTRATION (C.2.3.4)
Drywells for Limited Infiltration
Your property contains a stormwater management flow control BMP (best management
practice) called "limited infiltration," which was installed to mitigate the stormwater
quantity and quality impacts of some or all of the impervious surfaces on your property.
Limited infiltration is a method of soaking runoff from impervious area (such as paved
areas and roofs) into the ground. Infiltration devices, such as gravel filled trenches,
drywells, and ground surface depressions, facilitate this process by putting runoff in
direct contact with the soil and holding the runoff long enough to soak most of it into the
ground. To be successful, the soil condition around the infiltration devise must be able to
soak water into the ground for a reasonable number of years.
The infiltration devices used on your property include the following as indicated on the
flow control BMP site plan: ❑ gravel filled trenches, � drywells. The size, placement,
and composition of these devices as depicted by the flow control BMP site plan and
design details must be maintained and may not be changed without written approval
either from the City of Renton or through a future development permit from the City of
Renton.
Infiltration devices must be inspected annually and after major storm events to identify
and repair any physical defects. Maintenance and operation of the system should focus
on ensuring the system's viability by preventing sediment-laden flows from entering the
device. Excessive sedimentation will result in a plugged or non-functioning facility. If the
infiltration device has a catch basin, sediment accumulation must be removed on a yearly
basis or more frequently if necessary. Prolonged ponding around or atop a device may
indicate a plugged facility. If the device becomes plugged, it must be replaced. Keeping
the areas that drain to infiltration devices well swept and clean will enhance the longevity
of these devices. For roofs, frequent cleaning of gutters will reduce sediment loads to
these devices.
Instrument Number: 20190718000524 Document:COV Rec: $108.50 Page-6 of 8
Record Date:7/18/2019 12:50 PM King County, WA
PERFORATED PIPE CONNECTION (C.2.11)
Your property contains a stormwater management flow control BMP (best management
practice) called a "perforated pipe connection," which was installed to reduce the
stormwater runoff impacts of some or all of the impervious surface on your property. A
perforated pipe connection is a length of drainage conveyance pipe with holes in the
bottom, designed to "leak" runoff, conveyed by the pipe, into a gravel filled trench where
it can be soaked into the surrounding soil. The connection is intended to provide
opportunity for infiltration of any runoff that is being conveyed from an impervious
surface (usually a roof) to a local drainage system such as a ditch or roadway pipe system.
1. The size and composition of the perforated pipe connection as depicted by the flow
control BMP site plan, Exhibit B, must be maintained and may not be changed
without written approval either from the City of Renton or through a future
development permit from the City of Renton.
2. The soil overtop of the perforated portion of the system must not be compacted or
covered with impervious materials.
Instrument Number: 20190718000524 Document:COV Rec: $108.50 Page-7 of 8
Record Date:7/18/2019 12:50 PM King County, WA
CONPIGURATION ON SLOPING GROUND
.:�.� �. .��� ��, �m�, � �� ��� ,� ����� ����,. .�. ��� �.. ���m��� �.��. �.� �. mm� ��,
� �DOWNSPOUT WITH CLEANOUT FILTER,SEE DETAIL �
CLEANOUT PER STD.PLAN 226.00
_. . _ _ _.__ �
10'MIN.LEVEL TRENCH WITH
_..,,..� �_� ._ _,_,. �_,..... ._.._
��'�.. PERFORATED PIPE,SEE NOTE 1 �
''__... _ ._.._.. 5'
�._._. ..,....,.. .._, ._, ...... .
_...._. _,., .,__ _._. �.,...__, .,_.,..., �.,...._, .,. MIN.—_,"M �
,_ �,. . ,. ...... �_.� ._ � �
�........ ...
...... �,...... _
�',.__. .._ ._.„... 5, '�1
.. ..---.---M�N.- —....__.. I � I�
„,.�, ._.����_ ..... �..,.._ .... I �_. ,�,....,�...
. .. � . . .... ._ �.. � � p
� ..... .._
mrr �_..w � � �
� . � .. _ ... ,.,.M _.. '.. �
� � �
' ""� ��� '� � CLEANOUT PER �
_. w �. __. ._...
� STD.PLAN 226.00
.__. ._. �.. � ...., r..,.. _. ..,.__�,�.. ��.. � �.. YSTEM �
..w., � � � �� e,,q �� � � �, �, � �TO STORM DRAIN S� �
.,,,.. .......,w,� '-.__� ... ...._..
_ , .,._...,._, AIN BYPASS�.�.». ��� .�,. � � � �. � � �. ��� �. ��� ���. � ��
, .. ....,.. '._ .�. . �
_.... .,._._ .. N. A I
,....._._ .. __. ... �
FOOTING DR
_,
�._...., __ �� „�.._. w yry ,....--� .""..._��',,__._�_..""',, MIN. MIN.� CLEANOUT PER �
......� . .... '. _..�_...., . _.._.'...._„ ._. ,_._. , STD.PLAN Z26.00 �
.... ... _, . ,� ...
..__.. ......... _ . ,...._. ..... �,......_ .,._,� _. _. ,., ��
I TO STORM DRAIN SYSTEM �
� DOWNSPOUT WITH CLEANOUT '
FILTER,SEE DETAIL 10'MIN.LEVEL TRENCH WITH
� PERFORATED PIPE,SEE NOTE 1 �
�� .��.. � ��.�, �.�.«. ���., � ..� ���;. .� ��� �,� ,�. �� � .�� ���. � .�. .�� ��� �,� ����. � � � ,,.�� ��
CONFIGURATION ON FLAT GROUND
PLAN VIEW OF PARCEL
COMPACTED TOPSOIL OR OTHER CLEAN FILL �
NON-WOVEN GEOTEXTILE FOR SEPARATION 6"MIN.PVC
ON TOP AND SIDES OF��fRENCH PER WSDOT PERFORATED PIPE
SPECIFICATIONS SECIION 9-33.2(1)TABLE 3 PER ASTM D1785
� � � � SOLIDS/
�t ,. � s �, ^'--�-6� �LEAVES
ti a, ��w ��, � ������ ����„ .
� �`" 6 MIN `°�
; ,� rs � -
�� �"�\°�;.�w�`,\`�`�.;�`- � .
��������y�*`"y r� �� ry . FILTER SCREEN
"� � � �^�„� 1 1/2"-3/4" WASHED
"- ���, �µ��.., �� ^' � C,��.' DRAIN ROCK �
18'MIN. �
� �'�,„� �`1 2'-5'TO
��°'��'� �"���. �� ��f.l'�')-6.�' ' GROUND
��� �� ,
���� ��� `t,`��=-e�-����' G> �-r�a �.�� . 1
"�` �' �' 24 MIN. ►�
UNDISTURBED NATIVE SOIL = TYPICAL DOWNSPOUT
MIN.1'ABOVE SEASONAL HIGH FILTER DETAIL
GROUNDWATER TABLE
SECTION A
NOTES:
1. TRFNCH LENGTH TO BE 10 FEET IN LENGTH FOR EVFRY 5,000 SF OF CONTRIBUTING IMPERVIOUS SURFACE,OR 35,000 SF
OF NON-NATIVE PERVIOt1S SURFACE,OR PORTION THEREOF.
GENERAL NQTES:
1. INFILTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM SWGLE-FAMILY OR DUPLEX HOMES OR TO CONTROL
BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION
CONTROL PROGRAM(UIC) FOR OTHER TYPES OF RUNOFF MANAGEMENT.
2. IMPERVIOUS AREAS LARGER THAN 10,000 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 35,000 SF MAY REQUIRE
LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL ENGINEER.
3. THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25%.
4. SEE CONSTRUCTION PLANS FpR SPECIFIC PROJECT REQUIREMENTS.
UNLESS OTHERWISE NOTED,DRAWING IS NOTTO SCALE(NTS)
STD. PLAN-263.40
� PUBuc woRKs PERFORATED STUB-OUT "PPR E°:
`� DEPARTMENT CONNECTION GAZ 9/28/2018 �
� rut,u�wo�i�s nemm�.n:,00� DATE
Instrument Number: 20190718000524 Document:COV Rec: $108.50 Page-8 of 8
Record Date:7/18/2019 12:50 PM King County, WA
DRYWELL DETAIL - �.2.2.G
� I ROOF
DOWNSPOUT/ CATCH BASIN
TIGHTLINE 1'X 1'
HOUSE 2'X 10'TRENCH
FFE: 104.85 � IE:103.0 W/6"PERFORATED
I p�pE 24"DEEP 12"-18"DIA.
� FG:104.35 PVC OR ADS PIPE
16.5'at 1% �8`s�dt o IE:102.5 wITH DROP IN GRATE
3i
i>�.�-�,.
FOOTINGDRAIN IE:103. `����r"`�''-,''�„����
FLOW 6°PVC "-�"��� 6"OVERFLOW
PIPE 6"PERFORATED `_ OUTLETPIPECONNECTED
TO PUBLIC STORM DRAIN SYSTEM
PIPE VIA EXISTING LOT DRAIN STUB
8.5'DIAMETER IE:103.0
DRY WELL HOLE FILLED WITH
PLAN VIEW 1�"-3"WASHED
NTS DRAIN ROCK IE:101.0
STORM STUB
24"DEEP 12"-18"DIA.PVC OR
ROOF DOWNSPOUT ADS PIPE WITH DROP IN
GRATE
IE OUT:103.0
MIN.OF 6"VERTICAL
RIM:1042 2'X 10'TENCH SEPARATION BETWEEN
W/6"PERF. RIM:104.0 INLET AND OUTLET
PIPE
TOPSOIL
HOUSE IE IN:103.0 6"OVERFLOW
FFE:104.85 FG:104.35 IE IN:102.5 � OUTLET PIPE CONNECTED
TO PUBLIC STORM DRAIN SYSTEM
VIA EXISTING LOT DRAIN STUB
1'MIN.
IE:103.2 FLOW 18.5'at 3%
16.5'at 1% IE:101.0
MIN.6"DIA. STORM STUB
DOWNTURNED PVC PIPE
ELBOW IE OUT:103.0 EXTEND STUB AND
FINE MESH SCREEN 102 INCH DIAMETER � m CONNECT USING
SIDES OF HOLE HOLE FILLED WITH W-a, � FILLINGS AS NEEDED
LINED WITH 1}"-3"WASHED j o
CATCH BASIN FILTER FABRIC DRAIN ROCK �
10'TO 15'MIN.AS REQUIRED MIN.1'ABOVE SEASONAL MIN 1'
HIGH GROUNDWATERTABLE,SEE
SECTION C222
�
SECTION
NTS