38" MIN.
WIDTH
WHITE POST
�62"
_I
I
2 4"
SEWER MANHOLE MARKER POST
SEWER MANHOLE MARKER NOTES:
SEWER MANHOLE MARKER POST SHALL BE EQUAL TO
CARSONITE UTILITY MARKER
SEWER MANHOLE MARKER POST TO BE USED FOR
SANITARY SEWER MANHOLES IN UNIMPROVED AREAS.
SEWER MANHOLE MARKER POST SHALL IDENTIFY THE
MANHOLE AS "SANITARY SEWER".
STD. PLAN - 404.2
4 PUBLIC WORKS SEWER MANHOLE MARKER POST
!.. DEPARTMENT
SEPTEMBER 2011
SANITARY SEWER NOTES AND SPECIFICATIONS
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WASTEWATER UTILITY.
1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND
THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND
MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET
OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICA TIONS ON
WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING
ANY WORK WITHIN PUBLIC RIGHT OF WAY.
3. ALL LOCATIONS OF EXISTING UTILI TIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID
DAMAGE OR DISTURBANCE.
4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO
STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL
NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED
BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO NOTIFY
THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY
OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS
IN PROGRESS
9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE
SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL
ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
10. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE
AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER
TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE
DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MA TERIALS TO
COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED.
11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL
BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE
APPROVED BY
12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS,
AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 198JI1991 METERS UNLESS
OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE
BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS.
13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE
SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE
COMPLETION OF CONSTRUCTION.
14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDA TION IN
ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON
PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA
STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE
TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MA TERIAL, AS WELL AS PLACEMENT AND
COMPACTION OF REQUIRED BEDDING MA TERIAL, TO UNIFORM GRADE SO TVA T THE ENTIRE LENGTH
OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING
SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE.
15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D
3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER
UTILITY.
16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES
ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2'DIAMETER CONCRETE RING POURED AT GRADE.
IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
W (SEE NOTE 7) LIMITS OF PIPE ZONE
-11, 0"
BEDDING MATERIAL FOR
SANITARY SEWER PIPE O.D. OF PIPE
(SEE NOTE 5)
FOUNDATION LEVEL
6"
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE, HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS.
5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)'
OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL.
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
7. TRENCH WID'H SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
PUBLIC WORKS
URI DEPARTMENT
Nlklov
7' I
T
PIPE BEDDING
FOR SANITARY SEWERS
NOT TO SCALE
STD. PLAN - 405
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR JOINT(S) (3/8" MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX. PIPE SIZE - 'E'
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
.A.
W
,C,
,D,
,E.
48" MH
48"
6" M!N.
5"MIN
24" MIN.
21" LID.
54" MH
54"
8" MIN.
5.5" MIN-
24" MIN.
24" I.D.
6c" MH
60"
8" MIN.
6" MIN.
42" MIN.
30" I.D.
NOTES:
1, STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 401-
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5, ALL JOINTS BETWEEN THE CONE. RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR O BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE,
B. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
11. IN UNIMPROVED AREAS. MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE.
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
STD. PLAN - 400.1
,�,� PUBLIC WORKS STANDARD SANITARY MANHOLE
�i� DEPARTMENT
SEPTEMBER 2011
r��
I
:�EX. SEWER MAIN
PROPERTY LINE
..T•.�••-••-••�.•-••_'•�
_rSPOOL (LENGTH AS NEEDED)
2
5
I
r
8" SEWER STUBE
h
FUTURE 4. 5R)F SEWER
J/r
2-x A" STUD MARKING POST PAINTED
I
SEWER MAIN TEE X 6" TEE
I 6" CAP]
WHITE WITH THE WORD 'SEWER' STENCILED
W I
IN 3" HIGH RLAM LETTERS AND j6 WIRE
WRAPPED AROUND THE STUD AND
EXTENDED TO THE TOP OF THE STUD.
COUPLIMG (TYP) t l
k a+l � •
I
IS -
�I
------------ ---T�� FZ=-------j
BEND AS -
REQUIRED .
EXISTING SANITARY
SEWER MAIN .OR IN. 0
6" SEWER STUB
` SEIKER MAIN SITE X 6" TEE
5'X6'xe' SURFACE CLE4NQLlT WITH CAST IRON RING AND COVER
(EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR
■+'PROVED EQUAL. SPECIFY -SEwm- ON uD).
(SEE SM. PLAN 403.1 FOR INSTALLATION)
�-JM EAGLE THREADED CLEAN -OUT AOAATER HUB
ec PLUG [OR APPROVED EQUAL)
-1
1 � FUTURE 4' SDE SEWER
6•X67(5• WTE LFUTLRE 5"x 4" REDUCER
RCC�PTABLE Pft4CED ES FOR SIDE
A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC 'TEE' USING STRUNG -BACK- FLEXIBLE COUPLINGS (FCRNCU OR APPROVED EQUAL.
B. CONCRETE WNW - CUT IN A NEW PVC 'TEE' USING 'STRONG -BACK- FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
C. PVC d C900 PVC MAIN - CUT IN NEW TEE USING RICO COUPLINGS OR CORE-ORILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL).
0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SAOOLE (OR APPROVED EQUAL
E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED.
3000 ps MIK ,•,rpC�O
CONCRETE }- �
BLOCJONG 2t; I�HORIZONTAL
iR
6" TEE
6 • MIN- SE M'm SEWM MAIN
MAIN
CONCRETE &99KIN9. ANGLE
Of 11LE AT MAIN BETWEEN 25' AND 45' URLCAL_SIDE SEWER
NOTE: UNLESS 0114ERM5E SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.3' COVER AT PROPERTY LINE OR 3-5'
LONER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER,
STANDARD SIDE SEWER STD. PLAN -406.1
• • PUBLIC WORKS O1E°
"+ DEPARTMENT INSTALLATION
SEWER MAIN TO PROPERTY LINE) law
rrr ww
RENTON;
SEWER
COVER & FRAME
PLAN VIEW
RULTH❑LES - 3 PLCS
EQUALLY SPACED 12U'
APART DN 23 1/16' (566r+m)
D[A B.C. (SEE DFTATL)
RECESSED
LIFT POCKET
SEWER
TU-I/2'
1 f4' 12-1/2'-
1'
2-1/4'
14'
i` 12-3/4"
I� 1
12-11 /4"
CAST IRON RING AND
Not to Scale
FRAME
7--n" nIAtarrro
DR
]AEILE
DOTES:
1. 8' AND 6" CLEAN -OUT RINGS AMC COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC.
No- 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY.
2. IN UNIMPROVED AREAS, POUR A 1'-0- THICK, 2'-O" SQUARE
CONCRETE, CLASS 3000. PAD AROUND THE RING AND COVER.
STD. PLAN • 403.1
URa . PUBLIC WORKS 8" OR 6" CLEANOUT "'°"°V'
Ui DEPARTMENT FOR SANITARY SEWER MAIN
NboF =a
COVER BOTTOM VIEW
25' DIA. (3) BLT SLIC, (ALLEN HEAD)
(63Sr1m7 1'
25nm7 5IB'-11 X 1.5 SS
[19mm1 � F III
9RUBBER WASHER
mm
8 3/4• 2 1/2-
[222mm] [64mr17
TYP
COVER SECTION VIEW
EON BOLTING DETAIL
26 1/2, DIA
1673mm1
25 1/4' DIA
E641mm7 11/16' 1/4' 1
1I4' C6nm7 nIA r
[27mml n127nn1
NEOPRENE GASKET
i i ve•
I 6'
[152mm1 E3mr)
� 1/g•
5/8' 23 3/8' DIA CL OPEN rR3mm1
L16rnr17 I I - 1594mn1 I GASKET GROOVE DETAIL
27 5/16' DIA _
1694mml
34 1/8' DIA
[667mm) NOTES:
FRAME SECTION VIEW 1- ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC. No. 3717C1 OR EOUAL.
2. USE FRAME AND COVER FOR STORM (SPECIFY
"DRAIN" ON COVER), SANITARY (SPECIFY
"SEWER"). OR WATER (SPECIFY "WATER").
STD. PLAN - 401
PL[BLIC WORKS MANHOLE FRAME AND COVER
DEPARTMENT
p DECEMBER 2008
ASBUILTS
S-403204
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
Pacific f'� f 11J . ►�J1J of w , SURVEYED: SCALE HORIZONTAL-
NAw 1988 DATE
z " J. HOPPER NOTED HORIZONTAL NAD ,983,,99, CHRI. CITY OF SOUND BLDGS& DEVETELLE LOPMENT, WENT LLC M IDGE -201 s
De�� •+ J J DRAWN: RENTON I PAIGE
P. PATEL ONE INCH DATUM 21222 132 N D AVE SE DIMING NO:
�!! 1 REVISION AS PER CITY COMMENTS ON 06/18/18 PJP 7/31/18 JH CHECKED:
Civil Erlyirle&rar1J w% S J. HOPPER AT FULL SCALE IF NOT ONE INCH Planning/Building/Public Works Dept. KENT, WA 98042 15
- I Planning Cary .!tJ �: irls� A L �-� N0. REVISION BY DATE APPR SEWER DETAILS AND NOTES
SCALE ACCORDINGLY
of 14YL't J. HOPPER �"� 15 �24